Tender For Construction Of Non-Residential Building Of Thana Mahigawa At Distt. Lucknow, Lucknow-Uttar Pradesh

Uttar Pradesh Housing And Development Board-UPAVP has published Tender For Construction Of Non-Residential Building Of Thana Mahigawa At Distt. Lucknow. Submission Date for this Tender is 06-06-2024. Building Work Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43000988
Corrigendum : Tender For Construction Of Non-Residential Building Of Thana Mahigawa At Distt. Lucknow
Open Tender
Indian
Uttar Pradesh
Lucknow
06-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Construction Of Non-Residential Building Of Thana Mahigawa At Distt. Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Apr-2024 Date Extend Date 06-06-2024

Key Value

Document Fees
INR 8850 /-
EMD
INR 1440000.0 /-
Tender Value
INR 7.20 Crore /-

Attachment

FileName File Description File Size
8076b1b9-a604-404d-94fc-f4575c4be62a.html Tender Notice 0 KB
BOQ_1588307.xls Tender Document 0 KB
TenderDocument.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of work - CONSTRUCTION OF NON-RESIDENTIAL BUILDING OF THANAMAHIGAWA ATDISTT-LUCKNOW.
Sl. No. Item Description
1Boring, Providing and installing cast in situ single under reamed piles ofspecified diameter and length below pile cap in M-25 cement concrete, tocarry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to embedded in pile cap etc. all complete.(Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles
2Vertical load testing of piles in accordance with I. S. 2911 ( part iv ) including installation of loading plateform & preperation of pile head or construction of test cap & dismantling of test cap after test etc. complete as per specification and the direction of Engineer - in - Charge . Initial Test
3Vertical load testing of piles in accordance with I. S. 2911 ( part iv ) including installation of loading plateform & preperation of pile head or construction of test cap & dismantling of test cap after test etc. complete as per specification and the direction of Engineer - in - Charge Routine Test
4Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil
5Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
6Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources)
8Providing andinjectingchemical emulsion for preconstructional antitermite treatment andcreatinga chemical barrier underand alroundthe column pits wall trenches basement excavation top surface if plinth filling junctionofwall and floor, alongthe the external perimeter ofbinding expansionjoints, surrounding ofpipes andconduits etc, complete (plinth area of the building at groundflooronly shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or anyotherapproved materialsuch as Heptrachlor or chordancewill be used Therateofapplicationofchemical emulsion shallbe asfollows : (1)Treatment for masonary & foundation 5 liters per/100 sqm.(2) Back fill inimmediate contact with foundation 7.5 liters/100sqm (3) Treatment of topsurfaceof plinth filling 5 liters/100 sqm (4)Treatmentjunction of wallandthe floor 7.5 liters /100 sqm (5)Treatmentofsoilalong external perimeter of building 7.5liters/100sqm. (6) Treatment of soil under apronalong external perimter 5 liters/100 sqm.
9Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (GF + FF + SF) BAND
10Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (GF + FF + SF) SLAB
11Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (GF + FF + SF) BEAM
12Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. FOUNDATION
13Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (GF + FF + SF) COLUMN
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
15Brick work with common burnt clay machine moulded perforated bricks of class designation 15 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
17Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
18Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
19Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
20Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) Single leaf
21Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. b) Extra for double leaf
22Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying ariming coat of approved steel primer all complete. Providing & fixing of hold fast for chaukhatsof doors and windows.
23Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying ariming coat of approved steel primer all complete. Providing & fixing of door / windows grill.
24Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying ariming coat of approved steel primer all complete. Z-Section steel windows
25Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
26Providing and fixing fly proof galvanized M.S. wire gauge to windows and lerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading
27Fixingofsteelorwoodenchaukhats in position (a) Door chaukhats
28Fixingofsteelorwoodenchaukhats in position (b) Window chaukhats
29Fixingofsteelorwoodenchaukhats in position (c) Ventilator chaukhats
30Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
3112 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
3215 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
33Making grooves & Drip Coarse 10 to 12mmwide x 8 mm deep inplaster of the walls or in ceiling vertically or horizontally as required.
34Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
35Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm
36Providing and laying Vitrified tiles in different sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
37Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick
38Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
39Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
40Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
41Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
42Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specificationsPainting wood work with Deluxe Multi Surface Paint of requiredshade. Two or more coat applied @ 0.90 ltr/10 sqm over anunder coat of primer applied @0.75 ltr/10 sqm of approvedbrand and manufacture
43Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
44Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
45Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
46Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 10.30.1 4.0 mm thick glass panes
47Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
48Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm
49Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm
50Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
51Providing&layingoflight cinder filling under floor of toilets&other sunken roofs.
52Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
53Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
5415 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand)
55Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
56Providing and fixing in polycorbonate Roofing sheeton trussfor sky light.
57Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
58Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers.
59Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform.
60Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
61Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
62Providing & Laying of CC Road in 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
63Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. 16.46.1 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade "A" sealing compound.
64Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
65Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) Apron & CC Road
6615 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) with neat finish.
67SANITARY FIXTURES & ACCESSORIES - I Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
68Providing and fixing water closet squatting pan (European type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required for European type W.C. pan with white plastic seat and lid.Make- Cera,Hindware.
69Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a)White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap.
70Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm
71Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe a) 32mm dia
72Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe b) 40mm dia
73Providing and fixing toilet paper holder a) C.P. brass
74Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required b) Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
75Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
76Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
77Providing & fixing Jaquar make C.P. brass bottle trap.
78Supplying & Fixing ofCP soap tray fixed to the wallwith PVC rubber plug with CP brass screws Cat No. C9946
79Providing & fixing 60x2cm. C.P. brass towelrail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screw.PARRYWARE C9948
80Providing & fixing 15 mm dia. C.P.2-in-1 wall mixture with accessories for shower. .PARRYWARE G3416A1
81Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC]
82Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore
83Providing 15 mm dia. inletC.P. brassProviding and Fixing C.P. Single flow overhead shower(Without Arm)-parryware T9901A1
84SOIL WASTE & VENT PIPES AND FITTINGS - II Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm diameter
85Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm
86Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. a) 110mm
87Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) (Pipe support : Intellotech / Easyflex / Chilly) The Pipes will be supportedby either rubber lined G.I. U strap clampson 50x50x5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 110 mm dia
88Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) (Pipe support : Intellotech / Easyflex / Chilly) The Pipes will be supportedby either rubber lined G.I. U strap clampson 50x50x5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 75 mm dia
89Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 110 x 75 mm
90Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) Reducing Tee 110x110x75 mm
91Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) Door Tee 110x110x110 mm
92Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) Door Tee 75x75x75 mm
93Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) Bend 110 mm
94Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) Bend 75 mm
95Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) Terminal Guard 110 mm
96Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) Terminal Guard 75 mm
97Providing and fixing in position PVC sleeves(6 kg/cm2 - IS:4985 or Type B - IS:13592)of upto 300 mm longin RCC beams, slabs, walls before pouring of concrete. (for crossing of soil/waste pipes in toilet) (Make : Supreme / Finolex / Prince) 140 mm
98Providing and fixing in position PVC sleeves(6 kg/cm2 - IS:4985 or Type B - IS:13592)of upto 300 mm longin RCC beams, slabs, walls before pouring of concrete. (for crossing of soil/waste pipes in toilet) (Make : Supreme / Finolex / Prince) 40 mm(For Bottel Trap)
99WATER SUPPLY PIPES AND FITTINGS - III Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall a) 32mm dia nominal bore (medium duty)
100Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall b) 50mm dia nominal bore (medium duty)
101Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. a) 32mm dia nominal bore.
102Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. b) 50mm dia nominal bore.
103Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall a)25mm dia nominal outer dia pipes
104Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall b) 32mm dia nominal outer dia pipes
105Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. a) 15mm dia nominal outer dia pipes
106Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. b) 20mm dia nominal outer dia pipes
107Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. c) 25mm dia nominal outer dia pipes
108Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. d) 32mm dia nominal outer dia pipes
109Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. a) 15mm nominal bore
110Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore
111Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. a) 15mm nominal bore
112Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore
113Providing and fixing gun metal gate valve with wheel of approved quality. a) 25mm dia nominal bore
114Providing and fixing gun metal gate valve with wheel of approved quality. b) 32mm dia nominal bore.
115Providing and fixing gun metal gate valve with wheel of approved quality. c) 50mm dia nominal bore.
116Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore
117Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
118INTERNAL SEWERAGE SYSTEM - IV Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter.
119Providing, laying and joining glazed stone ware pipes grade "A"with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100mm diameter
120Providing, laying and joining glazed stone ware pipes grade "A"with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. b) 150mm diameter
121Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. a) 100mm diameterS.W. Pipe
122Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. b) 150mm diameterS.W. Pipe
123Providing and fixing square mouth S.W. Gully trap grade "A" complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 150 and water tight C.I. cover with frame of 300 x 300mm.size (inside) the weight of cover to be notless than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. With Sewer bricks conforming to IS : 4885 a) 150 x 100 mm. size P type
124Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 150 (i) For Sewer Line
125Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 150Extra for depth of man hole size 90x80 cm
126Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
127Wiring for light point/fan point/exhaust fan point/call bell pointwith 1.5 sqmm FR PVC insulatedcopper conductor single core cable in surface / recessed PVC conduit,with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. Group A
128Wiring for twin control light point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required.
129Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire
130Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire
131Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire
132Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required. 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire
133Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 20 mm.
134Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair
135Supply and drawing of co-axial TV cable RG-6 grade, 0.7 mm. Solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed conduit as required.
136Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
137Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV Antenna socket outlet
138Supplying and fixing metal box of following size (nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in fromt including paintingetc. as required. 75 mm x 75 mm x 60 mm deep
139Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm)
140Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
141Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connection, painting etc. as required.
142Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps. modular socket outlet and 15/16 amps. modular switch, connection, painting etc. as required.
143Supplying and fixing followingway, three pole and neutral, sheet steel, TP MCB distribution board, 415 volts,on surface /recess,completewithtinnedcopper busbar, neutral busbar, earth bar, din bar,detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 4 way (4 + 12), Double door, horizontal type
144Supplying and fixing followingway, three pole and neutral, sheet steel, TP MCB distribution board, 415 volts,on surface /recess,completewithtinnedcopper busbar, neutral busbar, earth bar, din bar,detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).6 way (4 + 18), Double door, horizontal type6 way (4 + 18), Double door, horizontal type 6 way (4 + 18), Double door, horizontal type
145Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C" series,miniature circuit breakerMCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required single pole
146Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required.
147Supplying and fixing following rating,four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
148Supplying and fixing20 amps, 240 volts, SPN,industrial type socket outlet, with 2 poles and earth metal enclosedplug top alongwith 20 amps. "C" series, SP MCB in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket outlet, and complete with connections, testingandcommissioning etc. as required.
149Supplying and fixing following rating,four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
150Installation of exhaust fanupto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
151Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
152Supplying and fixing of call bell/buzzer suitablefor DC/ACsingle phase, 230 volts, complete as required.
153Earthing withGI earth pipe4.5 mtr long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc, with coke and salt as required.
154Supplying and laying25 mm x 5 mm. G.I. strip at 0.50 M. below ground as strip earth electrode, including connection and terminating with nut, bolt, spring, washer etc as required (jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50 mm).
155Providing and fixing 6 SWG dia G.I. wire onsurfaceorin recessfor loop earthing as required.
156Providing and fixing of circular / hexazonal cast ironor MS sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick MS sheetwith it top surface hacked for proer bonding, top lid shall be screwed into the cost iron/MS sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shal be made of 12 mm dia MS bar bent to shape as per standard drawing.
157Providing and fixing M.V. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronfrontsideas required.
158Supply and installing of following size of perforated Hot Dipped Galvanised Iron cable trays (Galvanisation thickness not less 50 miccrons) with preforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts etc as required 300mmwidth x 50mm depth x 1.6 mm thickness
159Supply of ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS : 374/79 and also comply with IS:1709/1984 with latest amendment the rated voltage 220/240 volts, 50 HZ single phase AC, the fan assembled should consists of down rod, blades, shackle canopies etc and with double ball bearing system. BEE 5 star rating - 1200 mm sweep
160Add for Invertor Wiring in wiring Point for light/Fan/Plug with 1.5 mm Cu Wire
161Providing and fixing of button holder.
162S/F of recess/surface/pendent mounted 6 to 8 watt LED down lighter having powder coated die cast aluminium housing with heat sink, diffuser / reflectorand driver set complete in all respectCategory AAA
163S/F of LED Tube Light with batten suitable for up to 1x22 watt LED tube light fitting including tube on surface complete in all respect. Category AAA
164Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6 sqmm cables, including tapping with insulating tape,etc. complete in allrespects.
165S/F of sheet steel enclosure for DP / TP / FP MCB with neutral link and earth terminal.Cat-A
166Supply and laying of ISI marked aluminum conductor PVC / XLPE insulated armoured, served, sheathed cable 1100volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sqmm 4 core
167Supply and fixing brass nickel plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor.10 Sqmm 4core
168Supply & fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm.
169Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work. 600x480x200 mm. size
170Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followedby two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work. 600x480x200 mm. size
171Supply and laying of ISI marked aluminum conductor PVC / XLPE insulated armoured, served, sheathed cable 1100volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 50 sqmm 3 1/2core
172Supply and fixing brass nickel plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor.50 sqmm 3 1/2core
173Supply & fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge. 50 sq.mm.
174Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work.600x480x200 mm. size
175Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followedby two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work.600x480x200 mm. size
176Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm,Phase to neutral-minimum 15mm,Cubical Panel Board ( MCCB Type), Main L.T. Panel (Meter Panel Board),Incoming :One (1)No.200Amp. MCCB-1No.,Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. ,One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. ,One (1) Set of Phase Indication Lamp. ,Bus Bar : One (1) No.200 A, TPN aluminimum bus bar of suitable length.,Outgoing : Phase indication lamps on each outgoing to be provided. ,100 Amp. MCCB- 1 No. ,63 Amp. MCCB- 3 No. ,Or outgoing as per site requirment(AS/SLD)
177Supply and laying of 1800 mm x 900 mm x 12 mm thick chequered rubber matting of tested quality.
178Supply and fixing 200 AMPfour pole Moulded case type on load change over switch with enclosure(also suitable for panel mounting with extra cost of bus bar) including the cost of labour, T & P , painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.
179Supply and fixingofsingle phase multifunctional electronic energy meter 10 to 60 Amp. capacity fitted in integral box on wall complete in all respect.
180Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required. 300mm sweep.
181Supply,instalation,testing, commissioning of 3 phase,KWH Meter with LCD display, RS pot, Wired Communication system with current limiter switch & reset button. (Make:-L&T)
182S/f of 10/20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
183PART-I-(FIRE FIGHTING INTERNAL) Supply, erection and testing of ISI marked M.S pipes (Class B) and specials etc. (as per IS : 1239) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing/erection of pipes with suitable flat/angle iron including specials i.e. bends tees, reducers, flanges etc. in proper position including all supports as per layout, including hangers for sprinkler piping, jointing by welding, aligning the pipe line, painting with a primer coat and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and for other instruments etc. Hydrostatic testing of system as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge.The quoted rats shall also include for making holes in masonry/RCC slab, wall, chases in wall etc. & making good the same to original conditions. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash) a) 100mm
184Supply, erection and testing of ISI marked M.S pipes (Class B) and specials etc. (as per IS : 1239) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing/erection of pipes with suitable flat/angle iron including specials i.e. bends tees, reducers, flanges etc. in proper position including all supports as per layout, including hangers for sprinkler piping, jointing by welding, aligning the pipe line, painting with a primer coat and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and for other instruments etc. Hydrostatic testing of system as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge.The quoted rats shall also include for making holes in masonry/RCC slab, wall, chases in wall etc. & making good the same to original conditions. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash) b)80mm
185Supply, erection and testing of ISI marked M.S pipes (Class B) and specials etc. (as per IS : 1239) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing/erection of pipes with suitable flat/angle iron including specials i.e. bends tees, reducers, flanges etc. in proper position including all supports as per layout, including hangers for sprinkler piping, jointing by welding, aligning the pipe line, painting with a primer coat and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and for other instruments etc. Hydrostatic testing of system as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge.The quoted rats shall also include for making holes in masonry/RCC slab, wall, chases in wall etc. & making good the same to original conditions. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash) c) 25mm
186Supply & fixing in position ISI marked cast iron double flanged butterfly valves as per IS :13095, suitable for pressure 15 KG/cm2 including transporting to worksite, supply & fixing nuts, bolts, gaskets, flanges & washers etc including testing, complete as per drawing & directions of the Engineer-in-charge.(MAKE : Kirloskar/ Venus/IVC/Zaloto/Kalpna) 100 MM NB
187Supply & fixing in position ISI marked cast iron double flanged Non Return Valves as per IS 5312, part -I including transportation to worksite, supply & fixing nuts, bolts gaskets and washers etc, complete with testing as per direction of the Engineer-in-charge. (MAKE : Kirloskar/ Venus/IVC/Zaloto/Kalpna) 100 MM NB
188Supply, fixing, testing & commissioning of 20mm bore and 30 meter long hose (Rubber lined dunlop pipe) and hose reel for first aid fire fighting conforming to IS : 884, with full swing drum, fixing brackets, 5mm dia shut off gun metal nozzle, 32 mm dia hand lever operated ball valve, connecting directly from the riser through 32mm dia GI pipe with sockets, elbows, nipples etc, includingproviding operating instructions on a metal plate and fixing it near hose reel.The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. (Make : Dunlop/Goodyear)
189Providing gun metal ISI marked 63MM dia Instantaneous pattern short branch pipes & 16mm dia Nozzle suitable for interconnections to hose pipe coupling as required. (Make : Minimax/Firex/Safex/ Newage) a) 100mm
190Providing ISI marked RRL (IS: 636 type-II) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) gun metal male and female coupling complete as required. (Make : Jayshree/Newage)
191Providing & fixing standard firemans axe with heavy rubber handle.
192S/I/T/C draining arrangement with vertical down comer complete in all respect
193S/I/T/C air vessel of suitable capacity made out of 6mm. thick MS.sheet with legs for bolting wall drain cock etc. complete in all respects.
194Providing, fixing, testing & commissioning of ball valve.( size 25 mm dia)
195Providing and fixing standard fire hose cabinet door (1000mm x 1800mm) suitable to fit in the duct made of not less than 16 SWG MS sheet having central opening glassed door (4 mm thick clear glass) including necessary locking arrangement with handle as required including painting (one coat primer and two coats of fire red colour).The door shall be fixed in the masonry wall or as required.The words Fire Hose to be painted on the box.
196Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt) (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. (b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class "B" insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it"s rated discharge at 65% of rated head. (c)Common bed plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc. (e) Pressure switch for automatic operation of motor including necessary wiring upto control panel. (f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT"s protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details. Discharge : 450 liter per minute Head : 35 meter
197Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
198Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
199Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Capacity 10000 litre
200S/I/T/C stand post type fire hydrant with 63mm. outlet complete with bolts, nuts and rubber insertions etc. as per the standard designconforming to 15-908-"75.
201Supply, Installation, Testing & Commissioning ofFire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. (Newage/Omex/Padmini)-4 Way
202PART-II-FIRE DETECTION SYSTEM SITC of Manual call point with mounting box complete as required.
203Sitc of Electronic hooter 6 watt output TAC approved with a range of 25-30 mtr.
204providing, installing, connecting, testing and networkable logic driven analogue addressable Main Fire Alarm Control and indicating panel.The panel shall be coupled to the PA system complete in all respect. 2 loop Panel
205Wiring with 2X1.5 sqmm solid PVC insulated copper conductor 100 volt grade wires in with concealed conduit including terminations, all labour and material etc complete
206Supply/Fixing of self illuminated "EXIT" sings made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site.
207Supply, installation, testing and commissioning of Analogue addressable Photo Smoke/Heat Detectors based withLED shall be visible from 360deg, complete as required. (Make :/ GST/Morley)
208Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
209Supply, Installation, Testing and Commissioning of Fault Isolator (GST/Morley)
210Supply, Installation, Testing and Commissioning of Monitor Module. (GST/Morley)
211Supplying, installation, testing & commissioning of addressable fire control module complete as required.
212Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
213Rain Water Harvesting Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. In all kind of soil upto 1.5m depth
214Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. In all kind of soil upto 1.5m to 3.0m. depth
215Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. In all kind of soil upto 3.0m to 4.5m. depth
216Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources)
217Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
218Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
219Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
220Centring and shuttering including struting , proping etc and removal of form for : Suspended floors, roofs, landings, balconies and access platform.
22115 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)1:4 (1 cement : 4 coarse sand)
222Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 19.15.1 With 20x20 mm square bar With 20x20mm square bar
223Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityM.D. -10- Circular shape 500mm internal diameter
224Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.
225Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia
226Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
227Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge.
228Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
229Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge.
230Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter.
231Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : a) 150mm diameter S.W. Pipe
232Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement :4coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4(1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. a) Inside size 60x60 cm & 60 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.
233Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M Septik Tank Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including getting out & disposal of excavated earth upto 1.5m as directed by Engineer in charge All kind of soil. In all kind of soil upto 1.5m depth
234Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including getting out & disposal of excavated earth upto 1.5m as directed by Engineer in charge All kind of soil. In all kind of soil upto 1.5m to 3.0m. depth
235Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources)
236Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
237Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). slab
238Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
239Suspended floors, roofs, landings, balconies and access platform
24015 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
241Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : 19.15.1 With 20x20 mm square bar
242Providing and fixing C.I. tee at the inlet and outlet of septic tank.
243Sand cast iron S&S pipe as per IS: 1729
244Providing & fixing of 75mm dia cast iron terminal guard.
245Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. Square shape 450 mm internal dimension
246Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -2.5- Circular shape 450mm internal diameter
247Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks
248External Electrification SUB HEAD-ICABLE SUPPLY, LAYING & TERMINATION Supply & laying of PVC insulated PVC sheathed armoured / unarmored aluminium/copper conductor cable directly in ground.The laying involves digging, making sand cushion cover on top and bottom of cable, providing brick support and filling with excavated earth for following sizes. 3c x 4 sqmm Cu. Stranded Arm
249Supply & laying of PVC insulated PVC sheathed armoured / unarmored aluminium/copper conductor cable directly in ground.The laying involves digging, making sand cushion cover on top and bottom of cable, providing brick support and filling with excavated earth for following sizes. 3c x 6 sqmm Cu. Stranded Arm
250Supply & laying of PVC insulated PVC sheathed armoured / unarmored aluminium/copper conductor cable directly in ground.The laying involves digging, making sand cushion cover on top and bottom of cable, providing brick support and filling with excavated earth for following sizes. 3c x 10 sqmm Cu. Stranded Arm
251Supply, making of cable end terminations with solderless lugs, heavy duty single compression gland etc, as required with earthing of cable glands. 2/3/3.5/4 CORES Cu. CABLE WITH Cu. LUGS 3c x 4 sqmm Cu. Stranded Arm
252Supply, making of cable end terminations with solderless lugs, heavy duty single compression gland etc, as required with earthing of cable glands. 2/3/3.5/4 CORES Cu. CABLE WITH Cu. LUGS 3c x 6 sqmm Cu. Stranded Arm
253Supply, making of cable end terminations with solderless lugs, heavy duty single compression gland etc, as required with earthing of cable glands. 2/3/3.5/4 CORES Cu. CABLE WITH Cu. LUGS 3c x 10 sqmm Cu. Stranded Arm
254Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
255SUB HEAD-IIEARTHING & PIPES Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
256Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
257Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
258Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
259SUB HEAD-IV- EXTERNAL LIGHT FIXTURES Supply, assembling, erection, testing and commissioning of light up the roads with pole mounted street light for better visibilty.Pole Mounted Luminaire IK07, IP66 Outdoor luminaire with direct light street optic, designed to use LED lamps with system wattage not more than of 90W should have delivered lumen output of 11000 lm in 5700K with CRI70. MacAdam Step: 3 Life Time: 100,000h - L90 - B10. Luminous efficiency (lm/W,real value):120 lm/w. Dimensions of the fixture should not be more than Length 644mm x Width 337mm. The optical assembly and the pole attachment system are made of EN1706AC 46100LF aluminium alloy, subjected to a multi-step, pre-treatment process, in which the main phases are degreasing, fluorozirconation (a protective surface film) and sealing (with a nano-structured silane layer). The painting stage consists of a primer and a textured liquid acrylic paint, cured at 150 °C, with a high level of weather and UV ray resistance. Option of adjusting the inclination in relation to the road surface of +20°/-5° (in 5° steps) for a pole-top installation and +5°/20° (in 5° steps) for a lateral installation. 5 mm thick sodium-calcium closing glass secured to product with 4 screws. The high IP rating is guaranteed by the silicone gasket placed between the two elements. Complete with monochrome LED circuit and polymer optic multilayer lenses. Electronic control gear with 100%-70% Middle of the Night profile. Driver with automatic internal temperature control system. Overvoltage protection: 10KV Common Mode and 6KV Differential Mode. Optic and wiring compartment can be opened with everyday tools. The light flow emitted in the upper hemisphere of the system in the horizontal position is null (in conformity with the strictest standards for the prevention of light pollution). All external screws are made of stainless steel. Complies with EN60598-1 and pertinentgulations and BIS. Make: Philips or Equivalent from WE-EF, EUROLITE, LED LINEAR, IBL, ERCO"
260Supply, assembling, erection, testing and commissioning of Ingrounds uplighters used to highlight the walls.Floor recessed light fixture with medium 24° Beam angle, having system wattage not more than 3.8W with miniumum lumen output of 470lm at 3000K CRI80,IP68 IK07, Imax 6299 Cd and LED"s with MacAdam Step:2 and lifespan of LED should be 74,000h - L80 - B10. Diameter of Light fixture should not be more than 50mm and depth of the installation casing should not be more than 101mm. Light fixture body is made of Body and frame in AISI 304 stainless steel installed without visible screws, an extra-clear, sodium - calcium tempered glass cove; A2 stainless steel cable gland with a 1800 mm long H05RNF type 2x1 mm² output power cable. The cable is provided with IP68 anti-transpiration device that consists of a silicone-coated joint located on the power cable. The glass unit, optical assembly and outer casing together guarantee a maximum static load resistance of 2000 kg. The maximum surface temperature of the glass is less than 40°. Luminaire protected against polarity inversion. Constant Current electronic transformer to be kept remotely in weather proof IP rated box or at dry location. The product is fixed to the outer casing using special locking seals with toolfree installation. The unit can be recessed in floors, ceilings or walls using the outer casing for installation. It can also be installed in counter walls and false ceilings using special spring accessories. Outer casing Made of plastic (polypropylene). Complete with front cap, cable extraction system and twin cable entrance. Make: iGuzzini Light Up Orbit or Equivalent from WE-EF, LED Linear, EUROLITE
261INSTALLATION OF SUBMERSIBLE PUMP (120 M. DEPTH) Transportation of mini drilling Rig machine with camp equipage to site.
262Drilling of 350mm dia bore hole with lowering of tubewell assembly.
263Supply and fixing of 200mm dia plain rigid PVC casingpipe (10 Kg./sqcm pressure rating) and accessories.
264Supply and fixing of 150mm dia plain rigid PVC slottedpipeand accessories.
265Supply and fixing of nylon jali around the slotted pipes complete as required.
266Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charg
267Supply of submersible pump of make KSB 5.0 HP with control panel, support wire etc. complete.
268Providing 3 core 2.5 sqmm PVC insulated copper conductor submersible cable.(from pump panel to submersible pump)
269Providing and fixing 65mm dia G.I. Pipe complete with fitting and clamps including cutting and making good the wall etc. (from submersible pump to ground level)
270Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality.
271Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect.
272Fixing, testing and commissioning for erection and lowering of submersible pump, 65mm dia GI column pipe, 3 core 2.5 sqmm submersible copper cable upto the control panel, supporting clamps, cable clips pressure gauge, connection line and all other accessories required for the proper completion of the work.
273Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.