}

Tender For Repair To External Lt Electric Supply Network And Other Connected Works, rangia-Assam

Military Engineer Services-MES has published Tender For Repair To External Lt Electric Supply Network And Other Connected Works. Submission Date for this Tender is 08-04-2024. Electrical Products Tenders in rangia Assam. Bidders can get complete Tender details and download the document.




Tender Notice

42996836
Corrigendum : Tender For Repair To External Lt Electric Supply Network And Other Connected Works
Open Tender
Indian
Assam
rangia
08-04-2024

Tender Details

Repair To External Lt Electric Supply Network And Other Connected Works

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-04-2024
2 03-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: REPAIR TO EXTERNAL LT ELECTRIC SUPPLY NETWORK AND OTHER CONNECTED WORKS AT RANGIA MIL STN UNDER GE RANGIA
Sl. No. Item Description
1S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 street light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/36 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge.
2All as per Item No. 01 here-in-above, but for 60 Watt LED Street light, complete all as specified and as directed by Engineer-in-charge.
3S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 Flood light fitting luminaire with high power LEDs as light source and electronic driver of capacity 120 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge.
4S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 4 Sqmm section, complete all as specified and as directed by engineer-in-charge.
5All as per Item No. 04 here-in-above, but for cross-sectional area 6 Sqmm, complete all as specified and as directed by Engineer-in-charge.
6S&F in-repair of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, complete all as specified and directed by Engineer-in-charge.
7Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 25 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing and taking down the existing old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
8All as per Item No. 07 here-in-above, but for cross-sectional area 35 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
9All as per Item No. 07 here-in-above, but for cross-sectional area 50 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
10All as per Item No. 07 here-in-above, but for cross-sectional area 70 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
11All as per Item No. 07 here-in-above, but for cross-sectional area 95 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
12All as per Item No. 07 here-in-above, but for cross-sectional area 120 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
13All as per Item No. 07 here-in-above, but for cross-sectional area 150 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
14All as per Item No. 07 here-in-above, but for cross-sectional area 185 Sqmm 3.5 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
15All as per Item No. 07 here-in-above, but for cross-sectional area 16 Sqmm 4.0 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
16All as per Item No. 07 here-in-above, but for cross-sectional area 10 Sqmm 2.0 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
17M&L for boring holes horizontally under road without damaging the road surface with the help of GI tubing not exc. 80mm bore dia for passing of UG cable, complete all as specified and directed by Engineer-in-charge. NOTE: GI Pipe will be measured and paid separately.
18M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
19M&L for Returning,filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
20M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
21M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge.NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
22Supply & Laying Fly ash Bricks, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
23S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
24All as per Item No. 23 here-in-above, but for 50mm bore (dia) GI Pipe, complete all as specified and as directed by Engineer-in-charge.
25All as per Item No. 23 here-in-above, but for 80mm bore (dia) GI Pipe, complete all as specified and as directed by Engineer-in-charge.
26Supply & Erecting in true vertical of Steel Tubular Swaged Pole Type 410-SP-31 (9.00 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws with and including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying two Coats of Aluminium Painting over a coat ofRed oxidePrimer including necessary earthwork in excavation in any type of soil, removal of surplus soil to a distance of not exceeding 50.0m, Cement Concrete 1:3:6, type C-2 (40mm graded aggregate) as in Foundation of Poles filled upto ground level and Cement Concrete 1:2:4, Type B-1(20mm graded aggregate) as in Coping/Padestal of Poles and finishing the Concrete surfaces Fair and Even including necessary Formwork as required at Site(s) and dismantling the existing old damaged LT pole of any type, complete all as specified and as directed by Engineer-in-charge. NOTE: Earthwork, Cement Concrete, etc. will not be measured and paid separately.
27M&L for Aluminium conductor steel reinforced (ACSR) (size and type as required at site) drawn for overhead lines with permissible sags and providing jumper with and including copper binding wire or aluminium tapes, including stringing, tightening, etc., including dismantling the existing old unserviceable ACSR, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
28Labour only for releasing Aluminium conductor steel reinforced (ACSR) (any size and type) of existing OH lines by un-binding from insulator of any description, re-fixing after stretching, re-stringing the conductor, removing excess sag, maintaining proper distance between conductors as ordered and binding with insulator with aluminium binding wire, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
29M&L for mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge.
30Labour only for fixing in original position of disturbed/dis-aligned mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge.
31S&F in-repair of Stay assembly of 16mm dia 1.18m long stay rod complete with all accessories as shown in electrical plate No. 1, size of plate 230x230x6mm, complete all as specified and directed by Engineer-in-charge.Note:- Cost of 01 no 65 x 90mm porcelain, vitreous, white, brown or green Loop type insulator, Galvanised stay strand of 7/3.15mm size upto 7.50m long stay strands with clamps and bolts, excavation and concrete shall deemed to be included in unit quoted rate.
32S&F in-repair of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified and directed by Engineer-in-charge.
33S&F in-repair of Shackle Type, porcelain, vitreous, white, brown or green insulator including one 31x3mm galvanised mild steel straps, washers, 12mm dia insulator bolts, washers and nuts, 75mm height, 90mm dia for 1100 volts grade, complete all as specified and directed by Engineer-in-charge.
34Fixing only in-repair of porcelain insulator of any type, any size and of any description, complete all as specified and directed by Engineer-in-charge.
35M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of synthetic enamel paint in alternate Yellow & Black Strips (5 Nos. Strip of 300 mm wide each) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint,complete all as specified and as directed by engineer-in-charge.
36S&F in-repair of MCCB 4 Pole, 415 Volts, 630 Amps, 50 Hz, conforming to IS/IEC 60898, with Thermal Magnetic release, overload, short circuitfault protection 3 phase, breaking capacity 50 KA, Ics=100% of Icu, with Spreader terminal of both ends, connecting and testing, complete all as specified and as directed by Engineer-in-charge.
37All as per Item No. 36 here-in-above, but for 400 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
38All as per Item No. 36 here-in-above, but for 250 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
39All as per Item No. 36 here-in-above, but for 200 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
40All as per Item No. 36 here-in-above, but for 160 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
41All as per Item No. 36 here-in-above, but for 125 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
42All as per Item No. 36 here-in-above, but for 100 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
43All as per Item No. 36 here-in-above, but for 63 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
44M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead of 32x6 mm by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 40 mm bore( light grade)and watering pipe 20 mm bore GI pipe(medium grade) andchamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) including taking down old damaged earthing, complete all as specified & testing on completion. NOTE:-(i)item includes the cost of 1.5 mtr length GI pipe for protection for GI earth lead.(ii) item rates includes the cost of 7.5 mtr GI earth lead.
45All as per Item No. 44 here-in-above, but using 4mm dia galvanised steel wire procteded by GI pipe of 15 mm dia (light grade) as earthing lead, complete all as specified and as directed by Engineer-in-charge.
46S&F in-repair of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip, complete all as specified and as directed by Engineer-in-charge.
47All as per Item No. 46 here-in-above, but using 4mm dia galvanised steel wire as earth continuity conductor, complete all as specified and as directed by Engineer-in-charge.
48Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) platform mounted Indoor cubical type LT Panel Board of size 900 X 700 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry andexit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand),Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB"s & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internallyincluding necessary preparation of surfaces all as specified and as directed, comprising of the following :- (a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job.(c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 400 Amps with colour coding for RYB & N - 01 Set INCOMING (d)MCCB250 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 36KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING (e)MCCB100 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-04 Nos. (f) Manual type Changeover switch of 100 Amp, 4 Pole, 415 Volts-01 No. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
49Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) platform mounted Indoor cubical type LT Panel Board of size 800 X 600 X 450 MM fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry andexit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos (Make- L&T/ Siemens/ Schneider/ Legrand),Digital ammeter 0-500 Amps with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand), digital voltmeter of 500Volts with selector switch (Make- L&T/ Siemens/ Schneider/ Legrand) and LED/ Neon type indicating lamps panel mounting type RYB-3 Nos (Make- L&T/ Siemens/ Schneider/ Legrand), internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB"s & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internallyincluding necessary preparation of surfaces all as specified and as directed, comprising of the following :- (a) Internal wiring with single core copper conductor cable/ PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (b) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job.(c) Bus bar chamber comprising 04 Nos aluminium strip bus bar mounted on DMC ( Dough Moulding Compound) insulator and PVC sheathed of capacity 400 Amps with colour coding for RYB & N - 01 Set INCOMING (d)MCCB200 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 36KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING (e)MCCB100 Amp, 4 Pole , 415 Volts rating with, overload, short circuitfault protection 3 phase with neutral link specially fixed out going supply (Breaking capacity 16KA)Ics=100% of Icu, with Spreader terminal of both side-02 Nos. (f) Manual type Changeover switch of 100 Amp, 4 Pole, 415 Volts-02 Nos. (Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication).
50M&L for Jumper connection at cut point on LT OH lines with suitable size of ACSR conductor (not less than 6/1 x 2.56 weasel), by binding, wraping, providing alkathine sleaves of required length not exceeding 1.5 m including testing on completion and taking down the existing old damaged one, complete all as specified and as directed by Engineer-in-charge.
51S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 32mm bore (Dia) light grade GI pipe of 1.2m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 32x6mm) forfixing of building security/ street light fitting as per existing, complete all as specified and as directed by Engineer-in- Charge.
52S&F in-repair of 10mm dia rigid PVC line separator/ spacer suitable for 2/3/4 LT line of wires, complete all as specified and directed by Engineer-in-charge.
53S&F in-repair of solar tubular battery of 75Ah, extra lead 20% higher backup, thicker tubes, long life, ultra low maintenance suitable for solar lighting, complete all as specified and directed by Engineer-in-charge. (MAKE- Exide/ Amaron/As existing)
54S&F in-repair of solar charger controller (PWM) of 24V/10A, charge battery for solar panel, protects battery from over charging and protects panel from reverse current, complete all as specified and directed by Engineer-in-charge.(MAKE- Exide/ Amaron/As existing)
55Supply only distilled water of 5lit packeged bottle for battery charger of solar light, complete all as specified and directed by Engineer-in-charge.
56S&F in-repair of digital panel meter of three phase basic Voltmeter class 1, accuracy class 1.0, input voltage measurement range 17-520 VAC (P-P), flush mounting 96x96mm with in-built selector switch, CT/PT site programmable, complete all as specified and directed by Engineer-in-charge. (MAKE- Havells/ L&T/ Schneider/ ABB/ Seimens/ Indoasian/ HPL)
57S&F in-repair of digital panel meter of three phase basic Ammeter class 1, accuracy class 1.0, input voltage measurement range 17-520 VAC (P-P), flush mounting 96x96mm with in-built selector switch, CT/PT site programmable, complete all as specified and directed by Engineer-in-charge. (MAKE- Havells/ L&T/ Schneider/ ABB/ Seimens/ Indoasian/ HPL)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail