Tender For Construction Of Administrative Building Of New Police Thana Sharda Nagar, Distt-Lakhimpur Kheri., lakhimpur-Uttar Pradesh

Uttar Pradesh Housing And Development Board-UPAVP has published Tender For Construction Of Administrative Building Of New Police Thana Sharda Nagar, Distt-Lakhimpur Kheri.. Submission Date for this Tender is 06-06-2024. Building Work Tenders in lakhimpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42989668
Corrigendum : Tender For Construction Of Administrative Building Of New Police Thana Sharda Nagar, Distt-Lakhimpur Kheri.
Open Tender
Indian
Uttar Pradesh
lakhimpur
06-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Construction Of Administrative Building Of New Police Thana Sharda Nagar, Distt-Lakhimpur Kheri.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Apr-2024 430/AC-8/75 dt. 15.04.2024 Date 06-06-2024

Key Value

Document Fees
INR 8850 /-
EMD
INR 1210000.0 /-
Tender Value
INR 6.05 Crore /-

Attachment

FileName File Description File Size
db6f18d2-0bbc-40e2-86f0-0a190fbecdd3.html Tender Notice 0 KB
BOQ_1588246.xls Tender Document 0 KB
Fin.pdf Tender Document 0 KB
Techs.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Construction of Administrative Building of New Police Thana Sharda Nagar, Distt-Lakhimpur Kheri.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. DSR 2.6.1
2In all kind of soil upto 1.5m to 3.0m. depth.DSR-2.6.1 & 2.26.1
3In all kind of soil upto 3m to 4.5m. depth DSR-2.6.1 & 2.26.1.2
4Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. DSR 2.25(a)
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR 2.27
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 4.1.8+(4.1.5-4.1.6)
7Construction of drain of size of size 150 x 150 mm along with apron including excavation,base concrete 1:4:8 in thickness of 7.5cm of and brick work in foundation 1:4( 1 cement : 4 coarse sand) and brickwork in half brick thick in foundation 25mm thick cement concrete (1:2:4 mix) flooring base and 20mm thick plaster (1:2) finished with neat cement. (Analysis)
8Providing andinjectingchemical emulsion for preconstructional antitermite treatment andcreatinga chemical barrier underand alroundthe column pits wall trenches basement excavation top surface if plinth filling junctionofwall and floor, alongthe the external perimeter ofbinding expansionjoints, surrounding ofpipes andconduits etc, complete (plinth area of the building at groundflooronly shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or anyotherapproved materialsuch as Heptrachlor or chordancewill be used Therateofapplicationofchemical emulsion shallbe asfollows : (1)Treatment for masonary & foundation 5 liters per/100 sqm.(2) Back fill inimmediate contact with foundation 7.5 liters/100sqm (3) Treatment of topsurfaceof plinth filling 5 liters/100 sqm (4)Treatmentjunction of wallandthe floor 7.5 liters /100 sqm (5)Treatmentofsoilalong external perimeter of building 7.5liters/100sqm. (6) Treatment of soil under apronalong external perimter 5 liters/100 sqm.Plinth area
9Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR 5.3
10Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slab DSR 5.3
11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). beam DSR 5.3
12Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) Foundation. DSR 5.1.2
13Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcemT 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 5.2.2
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)DSR 6.1.2
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) DSR6.4.2
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) DSR6.4.1
17Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) DSR 4.10
18Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. DSR 4.13
19Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR 22.7.1
20Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
2135 mm thick DSR 9.21.2
22double leaf shutters addextra in over all rates. (PWD- 470) DSR9.21.2+9.26
23Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
24Fabrication of holdfastfordoor chaukhats and windows. DSR 10.1
25Fabrication of grill / staircase railing.DSR 10.1
26Fabrication of Z-section steel windows.DSR 10.1
27Fabricationof angleiron door chaukhat of 40*40*5 mm. DSR 10.1
28Providing and fixing fly proof galvanized M.S. wire gauge to windows and lerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading. D.S.R.-9.51.2
29Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR-10.2
30Fixingofsteelorwoodenchaukhats in position as per direction of E/I.
31Door chaukhats
32Window chaukhats
33Ventilator chaukhats
34Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. DSR5.22.5
3512 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) DSR13.4.2
3615 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) DSR 13.5.2
37Making of grooves in plastered surface or moulding to R.C.C. projections.DSR 5.30
38Making of drip course in plastered surface or moulding to R.C.C. projections.DSR 5.30
39Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate. DSR 11.3.1
40Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. DSR11.41.2
41Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm DSR 11.46.2
42Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) DSR11.26.1
43Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.DSR 11.27
4452 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
45Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick
46Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR -11.37
47Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete On steel work. DSR 13.52.1
48Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture. DSR 13.48.2
49Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). DSR 13.47.1
50Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer. DSR 13.41
51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR 13.80
52Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 10.30.1 4.0 mm thick glass panes. DSR 10.30.1
53Providing and fixing of Stainless Steel sliding bolts16 mm dia with nuts and 250 mm long. (MR)
54Providing and fixing of Stainless Steeltowerbolt with 10 mm dia and screw. (i) 300 mm long (MR)
55Providing and fixing of Stainless Steeldoorhandleswith screws 100 mm long. (MR)
56Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper. DSR 9.101.2
576 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. DSR 13.17
58Providing&layingoflight cinder filling under floor of toilets&other sunken roofs.(AR)
59Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.D.S.R.-22.5
60Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edgesto give high gloss finish etc. complete at all levels.DSR 8.2.2.2
61Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter. DSR 12.41.2
62Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend.(DSR12.42.5.2)
63Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.DSR12.43.2
64Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.DSR 12.22
6515mm cement plaster on rough face of single or half brick wall of 1:4 mortar (13.5.1)
66Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats.DSR13.51
67Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.DSR 10.3
68Providing and fixing glass strips in joints of terrazo/ cement concrete floors 40 mm wide and 4 mm thick. DSR-11.13.1
69Centering and shuttering including strutting, propping etc. and removal of form for
70Lintels, beams, plinth beams, girders, bressumers and cantilevers.DSR 5.9.5
71Suspended floors, roofs, landings, balconies and access platform.DSR5.9.3
72Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR 5.9.5
73Foundations, footings, bases of columns, etc. for mass concrete. DSR 5.9.1
74Columns, Pillars, Piers, Abutments, Posts and Struts. DSR 5.9.6
75Providing and fixing of 8 to 10mm thick polycorbonate Roofing sheeton trussfor sky light with required necessory fittings and jointing materials i/c. supply of all material, labour, T&P etc. complete.
76Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners , stainlesssteel bolts etc., of required size, on the top of the floor or the side ofwaist slab with suitable arrangement as per approval of Engineer-in-charge,( for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.).DSR-10.28
77Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required
78White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 17.1.1
79Same as above but for European type W.C. pan with white plastic seat and lid.Make- Cera,Hindware. DSR-17.2.1
80Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. DSR-17.7.4
81Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm. DSR-17.10.1.3
82Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Semi rigid pipe. DSR-17.28.1
83a) 32mm dia.DSR-17.28.2.1
84b) 40mm diaDSR-17.28.2.2
85Providing and fixing toilet paper holder C.P. brass DSR-17.34.1
86Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required
87Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. DSR-17.4.2
88Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade. 8.10.2
89Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 17.31
90Providing & fixing Jaquar make C.P. brass bottle trap. (NS)
91Supplying & Fixing ofCP soap tray fixed to the wallwith PVC rubber plug with CP brass screws Cat No. C9946 (NS)
92Providing & fixing 60x2cm. C.P. brass towelrail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screw.PARRYWARE C9948 (NS)
93Providing & fixing 15 mm dia. C.P.2-in-1 wall mixture with accessories for shower. .PARRYWARE G3416A1 (NS)
94Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC] (NS)
95Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore (NS)
96Providing 15 mm dia. inletC.P. brassProviding and Fixing C.P. Single flow overhead shower(Without Arm)-parryware T9901A1 (NS)
97Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings, clean outs etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) (Pipe support : Intellotech / Easyflex / Chilly) The Pipes will be supportedby either rubber lined G.I. U strap clampson 50x50x5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The The cost will include all support arrangements. The work includes cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site.
98110 mm dia (NS)
9975 mm dia(NS)
100Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 110 x 75 mm(NS)
101Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.. (Make : Supreme / Finolex / Prince) (NS)
102Reducing Tee 110x110x75 mm (NS)
103Door Tee
104110x110x110 mm (NS)
10575x75x75 mm (NS)
106Bend
107110 mm (NS)
10875 mm(NS)
109Terminal guard.
110110 mm (NS)
11175 mm(NS)
112Providing and fixing in position PVC sleeves(6 kg/cm2 - IS:4985 or Type B - IS:13592)of upto 300 mm longin RCC beams, slabs, walls before pouring of concrete. (for crossing of soil/waste pipes in toilet) (Make : Supreme / Finolex / Prince)
113140 mm (NS)
11440 mm(For Bottel Trap) (NS)
115Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.(internal work)
116Exposed on wall
117a) 32mm dia nominal bore (medium duty) 18.10.4
118b) 50mm dia nominal bore (medium duty) 18.10.6
119Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.
120a) 32mm dia nominal bore. 18.40.4
121b) 50mm dia nominal bore. 18.40.6
122Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work)
123Exposed on wall
124a)25mm dia nominal outer dia pipes. 18.7.3
125b) 32mm dia nominal outer dia pipes. 18.7.4
126Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.
127a) 15mm dia nominal outer dia pipes. 18.8.1
128b) 20mm dia nominal outer dia pipes. 18.8.2
129c) 25mm dia nominal outer dia pipes.18.8.3
130d) 32mm dia nominal outer dia pipes.18.8.4
131Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore. 18.21.2.1
132Providing & fixing CP brass bib cock of approved quality conforming to IS 8931. 15mm nominal bore. 18.49.1
133Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore. 18.51.1
134Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931.15mm nominal bore. 18.53
135Providing and fixing gun metal gate valve with wheel of approved quality.
136a) 25mm dia nominal bore. 18.17.1
137b) 32mm dia nominal bore. 18.17.2
138c) 50mm dia nominal bore. 18.17.4
139Providing and fixing brass stop cock of approved quality.
140a) 15 mm nominal bore. 18.16.1
141b) 20 mm nominal bore. 18.16.2
142Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 18.48
143Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.Pipes 80mm to 300mm diameter. 2.10.1.2
144Providing, laying and joining glazed stone ware pipes grade "A"with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
145a) 100mm diameter.19.1.1
146b) 150mm diameter19.1.2
147c) 200mm diameter19.1.3
148Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
149a) 100mm diameterS.W. Pipe.19.2.1
150b) 150mm diameterS.W. Pipe 19.2.2
151c) 200mm diameterS.W. Pipe 19.2.3
152Providing and fixing square mouth S.W. Gully trap grade "A" complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm.size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. 150 x 100 mm. size P type with Sewer bricks conforming to IS : 4885. 19.4.2.2
153Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. 19.7
154Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 19.7.1
155With FPS bricks of class designation 150
156(i) For Sewer Line.19.7.1.1
157Extra for depth of man hole size 90x80 cm. 19.8.1.1
158Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. (DSR-19.7.2.1)
159Extra for depth of man hole size 90x120 cm (DSR-19.8.2.1)
160Constructing brick masonry manhole with 150 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. a) Inside size 60x60 cm & 60 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. (NS)
161Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design with 20x20 mm square bar. DSR-19.15.1
162Wiring for light point/fan point/exhaust fan point/call bell pointwith 1.5 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit,with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. Group A (DSR-1.10.1)
163Wiring for twin control light point with 1.5 sqmm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. DSR-1.11
164Wiring forcircuit / submain wiring alongwith earth wire withthe following sizes of PVC insulated,copper conductor single core cable in surface/ recessed PVC conduit as required.
1652 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire. (DSR-1.14.1)
1662 x 2.5 sq.mm. + 1 x 2.5 sq.mm. Earth wire. (DSR-1.14.2)
1672 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire. (DSR-1.14.3)
1682 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire. (DSR-1.14.4)
1694 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire. (DSR-1.14.9)
1704x16 sqmm + 2x6 sqmm Earth wire. (DSR-1.14.11)
171Supply and fixing of 20mm sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : DSR-1.21.1
172Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (DSR1.18.2)
173Supply and drawing of co-axial TV cable RG-6 grade, 0.7 mm. Solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed conduit as required.(DSR-1.19)
174Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
175Telephone socket outlet. (DSR-1.24.6)
176TV Antenna socket outlet. (DSR-1.24.7)
177Supplying and fixing metal box of following size (nominal size) on surface or recess with suitable size of phenolic laminated sheet cover in fromt including paintingetc. as required. 75 mm x 75 mm x 60 mm deep (DSR-1.22.1)
178Supplying and fixing 1 or 2 Module (75 mmX75 mm) size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(DSR-1.27.1)
179Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(DSR-1.26)
180Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connection, painting etc. as required. (DSR-1.31)
181Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps. modular socket outlet and 15/16 amps. modular switch, connection, painting etc. as required.(DSR-1.32)
182Supplying and fixing 4 way (4 + 12), Double door, horizontal type, three pole and neutral, sheet steel, TP MCB distribution board, 415 volts,on surface /recess,completewithtinnedcopper busbar, neutral busbar, earth bar, din bar,detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).(DSR-2.4.1)
183Supplying and fixing 6 way (4 + 18), Double door, horizontal type, three pole and neutral, sheet steel, TP MCB distribution board, 415 volts,on surface /recess,completewithtinnedcopper busbar, neutral busbar, earth bar, din bar,detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). (SL No-2.4.2)
184Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C" series,miniature circuit breaker (MCB)suitable for inductive load ofsingle pole in the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. (DSR-2.10.1)
185Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required.(DSR-"2.11)
186Supplying and fixing20 amps, 240 volts, SPN,industrial type socket outlet, with 2 poles and earth metal enclosedplug top alongwith 20 amps. "C" series, SP MCB in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket outlet, and complete with connections, testingandcommissioning etc. as required. (DSR-"2.18)
187Supplying and fixing 40amp. rating,four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR-2.13.1)
188Supplying and fixing 63 amps. rating,four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (SL No-2.13.2)
189Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (DSR-1.45)
190Installation of exhaust fanupto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required. (DSR-1.50.1)
191Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.(DSR-1.51)
192Supplying and fixing of call bell/buzzer suitablefor DC/ACsingle phase, 230 volts, complete as required.(DSR-1.38)
193Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.(Sl. No-725D)
194Supplying and laying25 mm x 5 mm. G.I. strip at 0.50 M. below ground as strip earth electrode, including connection and terminating with nut, bolt, spring, washer etc as required (jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50 mm).(DSR-5.9)
195Providing and fixing 6 SWG dia G.I. wire onsurfaceorin recessfor loop earthing as required.(DSR-5.16)
196Providing and layingearthconnections from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipefromearth electrode as required. (DSR-5.12)
197Providing and fixing of circular / hexazonal cast ironor MS sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick MS sheetwith it top surface hacked for proer bonding, top lid shall be screwed into the cost iron/MS sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shal be made of 12 mm dia MS bar bent to shape as per standard drawing. (DSR-10.18)
198Providing and fixing M.V. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronfrontsideas required.(DSR-2.21)
199Supply and installing of 300mmwidth x 50mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable trays (Galvanisation thickness not less 50 miccrons) with preforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts etc as required. (DSR-4.6.4)
200Providing, laying and fixing 100 mm dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.(DSR-14.14.1)
201Add for Invertor Wiring in wiring Point for light/Fan/Plug with 1.5 mm Cu Wire. (189-A)
202S/F of single light wall bracket (Cat-AA) on matching M.D.F.E.G. board base etc. complete in all respects.(412)
203S/F of recess/surface/pendent mounted 6 to 8 watt LED down lighter having powder coated die cast aluminium housing with heat sink, diffuser / reflectorand driver set complete in all respect. Category AAA("1401)
204S/F of LED Tube Light with batten suitable for up to 1x22 watt LED tube light fitting including tube on surface complete in all respect.Category AAA ("1413)
205Supply of ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS : 374/79 and also comply with IS:1709/1984 with latest amendment the rated voltage 220/240 volts, 50 HZ single phase AC, the fan assembled should consists of down rod, blades, shackle canopies etc and with double ball bearing system.1200 mm sweep. (1501 (i)
206Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6 sqmm cables, including tapping with insulating tape,etc. complete in allrespects.("1129)
207S/F of sheet steel enclosure for DP / TP / FP MCB with neutral link and earth terminal.Cat-A (Sl no-1033)
208Supply & fixing of electronic Fan regulator (Modular), 120-280 V, ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer of work.(1203-C)
209Supply and laying of 50 sqmm 3 1/2core ISI marked aluminum conductor PVC / XLPE insulated armoured, served, sheathed cable 1100volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ("501)
210Supply and laying of 10 sqmm4 coreISI marked aluminum conductor PVC / XLPE insulated armoured, served, sheathed cable 1100volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(SL No-501)
211Supply and fixing brass nickel plated compression glands for 50 sqmm 3 1/2core PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor.(503)
212Supply and fixing of 10 sqmm4 core brass nickel plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor.(SL No-503)
213Supply & fixing of 50 sq.mm. plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge.(504)
214Supply & fixing of 10sqmmm plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge.(SI No-504)
215Construction of recess distribution board of 600x480x200 mm. size including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work.(1141-B)
216Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer 600x480x200 mm. size by two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work.(1147)
217Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.
218The minimum clearances between bus bars shall be as follows :
219Phase to phase - minimum 20mm
220Phase to neutral-minimum 15mm
221Cubical Panel Board ( MCCB Type)
222Main L.T. Panel (Meter Panel Board)
223Incoming :
224One (1)No.200Amp. MCCB-1No.
225Metering :
226One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.
227One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.
228One (1) Set of Phase Indication Lamp.
229Bus Bar :
230One (1) No.200 A, TPN aluminimum bus bar of suitable length.
231Outgoing :
232Phase indication lamps on each outgoing to be provided.
233100 Amp. MCCB- 1 No.
23463 Amp. MCCB- 3 No.
235Or outgoing as per site requirment(AS/SLD) (812)
236Supply and laying of 1800 mm x 900 mm x 12 mm thick chequered rubber matting of tested quality.(1136)
237Supply and fixing 200 AMPfour pole Moulded case type on load change over switch with enclosure(also suitable for panel mounting with extra cost of bus bar) including the cost of labour, T & P , painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.(379 A)
238Supply and fixingofsingle phase multifunctional electronic energy meter 10 to 60 Amp. capacity fitted in integral box on wall complete in all respect.(1209)
239Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required. 300mm sweep.
240S/f of 10/20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
241Supply, erection and testing of ISI marked M.S pipes (Class B) and specials etc. (as per IS : 1239) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing/erection of pipes with suitable flat/angle iron including specials i.e. bends tees, reducers, flanges etc. in proper position including all supports as per layout, including hangers for sprinkler piping, jointing by welding, aligning the pipe line, painting with a primer coat and two coats of synthetic enamel fire red colour, providing tapping for pressure gauges and for other instruments etc. Hydrostatic testing of system as specified, flushing & cleaning by water etc. complete as per drawings & direction of the Engineer-in-charge.The quoted rats shall also include for making holes in masonry/RCC slab, wall, chases in wall etc. & making good the same to original conditions. DSR-2022, S.I. No. 18.7
242MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)
243a) 100mm- 18.7.7
244b)80mm - 18.7.6
245c) 25mm - 18.7.1
246Supply & fixing in position ISI marked cast iron double flanged butterfly valves as per IS :13095, suitable for pressure 15 KG/cm2 including transporting to worksite, supply & fixing nuts, bolts, gaskets, flanges & washers etc including testing, complete as per drawing & directions of the Engineer-in-charge.(MAKE : Kirloskar/ Venus/IVC/Zaloto/Kalpna)100 MM NB. DSR - 2022, S.I. No. 18.11.5
247Supply & fixing in position ISI marked cast iron double flanged Non Return Valves as per IS 5312, part -I including transportation to worksite, supply & fixing nuts, bolts gaskets and washers etc, complete with testing as per direction of the Engineer-in-charge. (MAKE : Kirloskar/ Venus/IVC/Zaloto/Kalpna) 100 MM NB - DSR - 2022, S.I. No. 18.14.5
248Supply, fixing, testing & commissioning of 20mm bore and 30 meter long hose (Rubber lined dunlop pipe) and hose reel for first aid fire fighting conforming to IS : 884, with full swing drum, fixing brackets, 5mm dia shut off gun metal nozzle, 32 mm dia hand lever operated ball valve, connecting directly from the riser through 32mm dia GI pipe with sockets, elbows, nipples etc, includingproviding operating instructions on a metal plate and fixing it near hose reel.The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. (Make : Dunlop/Goodyear) DSR - 2022, S.I. No. 18.17.1
249Providing gun metal ISI marked 63MM dia Instantaneous pattern short branch pipes & 16mm dia Nozzle suitable for interconnections to hose pipe coupling as required. (Make : Minimax/Firex/Safex/ Newage) 100mm - DSR - 2022, S.I. No. 18.18.2
250Providing ISI marked RRL (IS: 636 type-II) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) gun metal male and female coupling complete as required. (Make : Jayshree/Newage) DSR - 2022, S.I. No. 18.16.2
251Providing & fixing standard firemans axe with heavy rubber handle.-MR
252S/I/T/C draining arrangement with vertical down comer complete in all respect - MR
253S/I/T/C air vessel of suitable capacity made out of 6mm. thick MS.sheet with legs for bolting wall drain cock etc. complete in all respects. - DSR - 2022, S.I. No. 18.20
254Providing, fixing, testing & commissioning of ball valve.( size 25 mm dia) - MR
255Providing and fixing standard fire hose cabinet door (1000mm x 1800mm) suitable to fit in the duct made of not less than 16 SWG MS sheet having central opening glassed door (4 mm thick clear glass) including necessary locking arrangement with handle as required including painting (one coat primer and two coats of fire red colour).The door shall be fixed in the masonry wall or as required.The words Fire Hose to be painted on the box. - MR
256Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt)
257(a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.
258(b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class "B" insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it"s rated discharge at 65% of rated head.
259(c)Common bed plate of fabricated mild steel channel or cast iron type.
260(d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.
261(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel.
262(f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT"s protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details. Discharge : 450 liter per minute-DSR - 2022, S.I. No. 18.4.2. Head : 35 meter
263Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2016-1131 (A)
264Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2016-1132 (A)
265S/I/T/C stand post type fire hydrant with 63mm. outlet complete with bolts, nuts and rubber insertions etc. as per the standard designconforming to 15-908-"75.- MR
266Supply, Installation, Testing & Commissioning ofFire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. (Newage/Omex/Padmini)-4 Way
267SITC of Manual call point with mounting box complete as required. - DSR - 2022, S.I. No. 17.2.14
268Sitc of Electronic hooter 6 watt output TAC approved with a range of 25-30 mtr. DSR - 2022, S.I. No. 17.2.15
269providing, installing, connecting, testing and networkable logic driven analogue addressable Main Fire Alarm Control and indicating panel.The panel shall be coupled to the PA system complete in all respect. 2 loop Panel - DSR - 2022, S.I. No. 17.2.1.2
270Wiring with 2X1.5 sqmm solid PVC insulated copper conductor 100 volt grade wires in with concealed conduit including terminations, all labour and material etc complete- DSR - 2022, S.I. No. 17.5.2
271Supply/Fixing of self illuminated "EXIT" sings made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site. MR
272Supply, installation, testing and commissioning of Analogue addressable Photo Smoke/Heat Detectors based withLED shall be visible from 360deg, complete as required. (Make :/ GST/Morley) DSR - 2022, S.I. No. 17.2.4
273Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.) DSR - 2022, S.I. No. 17.2.9
274Supply, Installation, Testing and Commissioning of Fault Isolator (GST/Morley) MR
275Supply, Installation, Testing and Commissioning of Monitor Module. (GST/Morley) MR
276Supplying, installation, testing & commissioning of addressable fire control module complete as required. DSR - 2022, S.I. No. 17.2.10
277Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.- DSR - 2022, S.I. No. 17.2.5
2781:2:4 (1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR-4.1.3)
279Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. 16.46.1 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade "A" sealing compound. (DSR-16.46.1)
280Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. DSR 16.68
281Providing and fixing C.I. tee at the inlet and outlet of septic tank.(DSR-7087)
282Sand cast iron S&S pipe as per IS: 1729(DSR-17.35.2.1)
283Providing & fixing of 75mm dia cast iron terminal guard. (DSR-17.56.2.1)
284Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
285Square shape 450 mm internal dimension (DSR-19.19.2.2)
286M.D. -2.5- Circular shape 450mm internal diameter (DSR-19.19.1.3)
287Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks (DSR-19.32.1)
288Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. (DSR-23.1.1.1)
289Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia (DSR-23.4.2)
290Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR-23.5)
291Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge. (DSR-23.6)
292Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (DSR-23.7)
293Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge.(DSR-23.8)
294Supply & laying of PVC insulated PVC sheathed armoured / unarmored aluminium/copper conductor cable directly in ground.The laying involves digging, making sand cushion cover on top and bottom of cable, providing brick support and filling with excavated earth for following sizes.3/4 CORES Cu. CONDUCTOR
2953c x 4 sqmm Cu. Stranded Arm (M.R)
2963c x 6 sqmm Cu. Stranded Arm (M.R)
2973c x 10 sqmm Cu. Stranded Arm (M.R)
298Supply, making of cable end terminations with solderless lugs, heavy duty single compression gland etc, as required with earthing of cable glands.2/3/3.5/4 CORES Cu. CABLE WITH Cu. LUGS
2993c x 4 sqmm Cu. Stranded Arm (M.R)
3003c x 6 sqmm Cu. Stranded Arm (M.R)
3013c x 10 sqmm Cu. Stranded Arm (S.I. 9.1.7)
302Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
3032 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(S.I. 1.7.2)
3042 X 6 sq. mm + 1 X 6 sq. mm earth wire(S.I. 1.7.4)
305Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(S.I. 5.2)
306Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(S.I. 5.15)
307Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.(S.I.5.16)
308Supplying and laying of 90 mm dia (OD-90 mm & ID-76 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.(S.I.14.15.2)
309Supplying of 9 mtr. long galvanised Square Section GI single arm( length of arm should be as per requirement) pole at site of works having 70mm at top and 130 mm at bottom, made out of minimum 3mm thick Galvanized sheet, Square shape Pole duly painted with PU paint of approved colour/ shade, complete with 220mm x 220mm x 12 mm base plate with suitable hole for fixing the pole ,suitable for wind speed of 160 km/hr and suitable hinged opening with locking arrangment. The pole shall be complete with 1 No. 6amp DP MCB and 2 numbers 15 amp. 4 way connectors as required including 2nos. earthing stud with a set of 4 numbers M16 x 450mm long "J" type EN 8 grade foundation bolts along with suitable template as per drawing and as required for the 6 mtr long pole.M.R.
310Providing and making foundation for 9 Meter high pole complete in all respect including excavation, back filling, steel reinforcement with cold twisted bar, PCC with 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) & main foundation 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), fixing of "J" Bolts ("J" bolts provided by other agency) including curing, back filling etc. as required, including suitable length of 32 mm GI pipe for cable entry size & design of foundation shall be as per drawing complete as required.
311Erection of octagonal pole of 9 mtr. Length on existing foundation, fixing of nuton bolt afterapplying required pressure including inter connection in existing juction box complete as required.
312Supply, assembling, erection, testing and commissioning of light up the roads with pole mounted street light for better visibilty.Pole Mounted Luminaire IK07, IP66 Outdoor luminaire with direct light street optic, designed to use LED lamps with system wattage not more than of 90W should have delivered lumen output of 11000 lm in 5700K with CRI70. MacAdam Step: 3 Life Time: 100,000h - L90 - B10. Luminous efficiency (lm/W,real value):120 lm/w. Dimensions of the fixture should not be more than Length 644mm x Width 337mm. The optical assembly and the pole attachment system are made of EN1706AC 46100LF aluminium alloy, subjected to a multi-step, pre-treatment process, in which the main phases are degreasing, fluorozirconation (a protective surface film) and sealing (with a nano-structured silane layer). The painting stage consists of a primer and a textured liquid acrylic paint, cured at 150 °C, with a high level of weather and UV ray resistance. Option of adjusting the inclination in relation to the road surface of +20°/-5° (in 5° steps) for a pole-top installation and +5°/20° (in 5° steps) for a lateral installation. 5 mm thick sodium-calcium closing glass secured to product with 4 screws. The high IP rating is guaranteed by the silicone gasket placed between the two elements. Complete with monochrome LED circuit and polymer optic multilayer lenses. Electronic control gear with 100%-70% Middle of the Night profile. Driver with automatic internal temperature control system. Overvoltage protection: 10KV Common Mode and 6KV Differential Mode. Optic and wiring compartment can be opened with everyday tools. The light flow emitted in the upper hemisphere of the system in the horizontal position is null (in conformity with the strictest standards for the prevention of light pollution). All external screws are made of stainless steel. Complies with EN60598-1 and pertinent regulations and BIS. Make: Philips or Equivalent from WE-EF, EUROLITE, LED LINEAR, IBL, ERCO"
313Supply Installation and Comissioning of 25W Postop, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear Cover offers bright illumination for different applications. Cat Ref: Havells or equivalent.
314Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250mm diameter. (DSR-19.21.1)
315Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work)
316a) 65mm nominal bore.(DSR-18.12.7)
317b) 50mm nominal bore. (DSR-18.12.6)
318c) 32mm nominal bore. (DSR-18.12.4)
319Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.
320a) 65mm nominal bore.(DSR-18.41.7)
321b) 50mm nominal bore. (DSR-18.41.6)
322c) 32mm nominal bore. (DSR-18.41.4)
323Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
324a) 65mm(DSR-18.17.5)
325b)50mm(DSR-18.17.4)
326c)32mm(DSR-18.17.2)
327Constructing masonry Chamber 30x30x50 cm, inside with 150 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for stop cock, withC.I. surface box 100x100x75mm(inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks Class-150 (DSR-18.32.1)
328Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
32925 to 40 mm dia nominal bore(DSR-18.13.1)
33050 to 80 mm dia nominal bore(DSR-18.13.2)