Tender For Provision Of Hard Standing At P 50, Special Repair In P 25, Renovation Of Flooring, Special Repair To Lt Supply And Provision Of Shed At 4 Afsb Varanasi Under Ge Af Stn Gorakhpur, gorakhpur-Uttar Pradesh

Military Engineer Services-MES has published Tender For Provision Of Hard Standing At P 50, Special Repair In P 25, Renovation Of Flooring, Special Repair To Lt Supply And Provision Of Shed At 4 Afsb Varanasi Under Ge Af Stn Gorakhpur. Submission Date for this Tender is 08-04-2024. Shed Construction Tenders in gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42986413
Corrigendum : Tender For Provision Of Hard Standing At P 50, Special Repair In P 25, Renovation Of Flooring, Special Repair To Lt Supply And Provision Of Shed At 4 Afsb Varanasi Under Ge Af Stn Gorakhpur
Open Tender
Indian
Uttar Pradesh
gorakhpur
08-04-2024

Tender Details

Tender For Provision Of Hard Standing At P 50, Special Repair In P 25, Renovation Of Flooring, Special Repair To Lt Supply And Provision Of Shed At 4 Afsb Varanasi Under Ge Af Stn Gorakhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94660.0 /-
Tender Value
INR 47.33 Lakhs /-

BOQ Items

Name of Work: PROVN OF HARDSTANDING AT P 50, SPL REP IN P 25, RENOVATION OF FLOORING, SPL REP TO LT SUPPLY AND PROVN OF SHED AT 4 AFSB VARANASI UNDER GE AF STN GORAKHPUR.
Sl. No. Item Description
1Dismantling wrought iron or mild steel work of any description not otherwise provided for.complete all as specified and directed.
2Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings completed all as specified and directed
3S&F steel almirah on wall with 4 Nos 10 mm dia 100 mm long fasteners all as specified and directed almirah shall be of size 760 mm long, 440 mm wide and 900 mm high made of 1 mm thick mild steel sheet, Front shutter shall have two levees. A steel chromium plated handle shall be provided to the shutter.Handle shall be 100 mm long.A three way locking device shall be provided to front shutters.Each leave of front shutter shall be hinged with two numbers butt hinges 15 mm long and shutters shall be side hung, specification all as per FD 1032. and as per sample kept in AGE (AF) Varanasi. Fixing shall be done as directed by engineer-in-charge with standard workmanship. All steel surfaces shall be spray painted with standard workmanship. All steel surfacs shall be spray painted with two coats of synthetic enamei paint over one coat of primer after preparation of steel surfaces complete all as specified and directed.
4Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
5M&L PCC (1:2:4) type B2 using (40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed .
6M&L for steel work in tubular post/trusses including special shaped washer, hollow section, angle iron, flat iron for fixed independently connecting purlin, rafters, MS plate as reqd forming holes bolted and welded attachment and curved shaped by welding making jointless by filling including cutting etc conforming to IS 1161-1979 grade St-240 including work as directed by Engr-in - Chargecomplete all as specified and directed.
7S&F for pre-painted galvatume aluminium zinc coated GI based corrugated, steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roofing covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
8S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall and making eaves gutter, fixed with gutterself tapping screws complete all as specified and directed
9S&F PVC (SWR) 110mm dia pipes single socketed in any length with rubber joints fixed to walls completed all as specified
10S&F PVC (SWR) 110mm dia pipe bends any radius
11S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
12M&L for preparation of previously untreated steel and iron surfaces of any description not otherwise described over 10 cm in width or girth and appiying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
13M&L applying 2 coats of black japan paint over a coat of red oxide zinc chrome primer on steel Surfacesover 10 cmgirth ingluding preparation of surface complete all as specified and directed .
14Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed
15M&L 15 mm thick screed bed or bedding layer of mortar in CM 1:4 for laying floor finishes neat cement slurry with 3.00 kg of cement per sqm complete all as specified and directed.
16M&L for rendering 10mm thick in CM 1:3 CM for dado / skirting on brick work finished fair and smooth for receiving tiles in vertical surfaces all as specified and directed
17Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
18Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
19M&L for Non - skid coioured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) set complete all as specified and as specified and directed
20M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed
21M&L for vitrified ceramic tiles 10 mm thick in light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
22M&L for vitrified ceramic tiles 10 mm thick in light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
23S&F Vitrified Ceramic tiles light shade 10 mm thick (double charged) (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Complete all as specified and directed.
24M&L Washing rubbing down and stoping of distempered and painted surfaces of wall incuding cornices etc and applying two coat of oil bound distemper white or tinted complete all specified and directed.
25M&L for two coats of white wash on ceiling old syrfaces complete all as specified and as directed
26Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store
27S&F steel water tubing15mm bore medium grade galvanised with all fittings such as bends, tees, nipples, elbows, reducers, etc fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
28S&F in repairs CP Grating 125 mm size complete all as specified and directed.
29S&Fin repair PVC (SWR) P/S trap 125/110 mm,setting and jointing with solventcement
30M&L in repair 75mm dia PVC (SWR) floortrap, plane with grating including jointing with solvent cement.
31S&F in repair Vitreous China Urinal, Half stall type,white (excluding flushing cistern, flush pipe and waste pipe) with urinal spreder
32S&F in repair vitreous china wash down water closet pan (pedestal pattern with including trap, seat cover, including connection to trap /drain and to flushing pipe anti syphonage pipe etccomplete including making good floor complete all as specified and directed.
33S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed
34S&F in repairs10 Ltrs capacity PVC flushing cisternvalveless, syphonic action type, low level,white, with inlet, ball wall, float and handle including brackets and connecting to pipes and fixing of chain and pull or lever if any complete all as specified and directed.
35S&F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
36S&F in repairs PVC waste pipe 32mm dia, 60 cm long for WHB/Urinalwithlong screw shanks and fly nuts, flanges end bedded in red lead cement and other fixed complete.
37S&F in repair 15mm bore dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed
38S&F in repair 15mm bore angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
39S&F in repair 15mm bore LDPE pipe 60cm long with brass nuts and washers on both ends complete all as specified and directed .
40S&F in repair vitreous China wash basin, angle back, size 630x450mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed
41S& in repair 15mm bore dia pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed
42Dismantling water tanks exc 250 & 500 Ltr and removing to store complete all as specified and directed.
43S&F Rotational moulded polyethylene 500 Ltr water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in white colour complete all as specified and directed.
44S&F 20mm PVC Nipple suitable for HDPE Water tank (Min Wt 15mm-38gms) complete all as specified and directed.
45S&F 15mm PVC Nipple suitable for HDPE Water tank (Min Wt 15mm-38gms) complete all as specified and directed.
46S&F ball brass valveshigh pressurewith polyethylene float and fly nut completescrewed for iron pipe or brass ferrule and fixed to 20 mm bore , complete all as specified and as directed.
47Taking down chowkhats and frame exc 1.5 Sqm but n.exc 4 Sqm eachwith shutters without taking off shutters from the frames, area n.exc 1.50 sqm each and removal to store including cuttingholes for removalof hold fast complete all asspecified.
48S&FSolid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
49S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
50S&F 150mm, aluminium anodised, barrel tower bolts of extruded section and fix complete all as specified and directed.
51S&F 150 mm Aluminium handles , cast type, anodisedetc.complete all as specified and directed.
52M&L for 100 mm thick cement concrete Type B-2 (1:2:4) using( 40mm graded stone aggregate ) as in sub base of floor compete all as specified and directed.
53M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed
54M&L for plain cement concrete 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in copingincluding necessary form work all as specified.
55Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point in soft / soil all as specified and directed .
56Taking downof shutters of any description exc 1.0 Sqm but n.exc 2.0 sqm and refixing in the same openning after easing and adjusting. Complete all as specified and directed.
57S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/wall or in floors. Complete all specified and directed.
58S&F PVC (SWR) pipes bend 110mm dia.Complete all as specified and directed.
59M&L for cement concrete 100 mm thick type D2 ( 40 mm graded aggregates) 1:4:8 as in base of floor.Compete all as specified and directed.
60M&L for cement concrete Type B1( 20 mm graded aggregates) 1:2:4 as in sides of interlocking tiles.Compete all as specified and directed.
61Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil. Complete all as specified and directed.
62.Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete
63M&L for 150mm thick broken to gauge exc 63mm and n.exc 100 mm, Complete all as specified and directed.
64M&L for Cement concrete Type D1, 1:4:8, 40 mm graded in foundations, filling and mass concrete. Complete all as specified and directed.
65M & L for power/sub main wiring with two runs of single core 2.5 sqmm size and one run of single core 1.5 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including PVC casing caping complete all as specified and directed.( Note - Two runs of 2.5 sq mm single core copper conductor and one runs of 1.5 Sq mm copper conductor shall be measured as one unit length.)
66M&L light fan point controlled by one switch with PVC insulated, unsheathed , multi stranded, single core copper conductor FRLS ( Flame Retardant Low Smoke) cable 1.50 Sqmm suitable for fixing in concealed PVC conduit of size not less than 20 mm dia with metalflush boxes including white cover plate with frame of required module.Metal flush box should not less than2 mm thickduly painted inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer of requiredmodule suitable for housing modular switches, socket, fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor FRLScable 1.50 Sqmm used as earth wire to commen earth and connected to common dolly drawn in same conduit all as specified.
67Supply & Fixing switch modular single pole, one way 6 Amp ,01 module, complete all as specified and directyed at site.
68Supply & Fixing ceiling rose surface backlite 65X20 mm two to three terminals complete, complete all as specified and directyed at site.
69Supply, fabricate, erect, testing and commissioning LT outdoor feeder pillar box 500x500x200mm totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ,AC supply, factory made, fully compartmentalized made out of 3.15 mm thick CRCA sheet for load bearing and2.00 mm thick non load bearing portions, protection ofenclosure IP-54 as per IS-2147 of 1962 complete with pre-treatmentwith approvedcolour including suitable angle iron/flat iron frame work/supports, danger notice board, excavation and earth work, PCC foundation etc, out door type, cubical typeas required with and including the following, supplied fitted and connected internally and connected to existing earthing complete all as specified and directed. (a) Incoming:- (i) MCB SPN 40 to 63 Amps240 volts, 10 KA, "C" curve. -01 No (ii) 4 Nos bus bar of equal size of aluminium conductor with PVC coloured heat shrinkable type sleevescontinuous rating 100 Amps mounted on nonresin type insulators with CTs digitaltype ammeter 0-100 Amp-01 Nos and volt meter 0-500 Volts with selector switches , set of LED typeindicating lamps R,Y,B. (b) Outgoing:- (i)MCB SP 5 to 32 Amps240 volts, 10 KA, "C" curve.-6 Nos. (ii)Socket outlet 3/6 pin,6/16 Amps outlet each controlled by MCB SP 16 Amps individually -02 Nos.
70Supply and fix LED Flood light 60 W IP 66 ( LED efficacy not less than 130 lumen/watt) including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size .Make Philips/Bajaj/Havells/Wipro/ HPL.
71Supply and laying ,jointing and testingXLPE insulated extrudedPVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 10 Sqmm 2 core, complete all as specified and directyed at site.
72Takingdowntheexisting defectiveLTUGcable fromtrenches / pipes/ poleforfault finding / replacement, all as specified and directed of any size between 10 Sq mm 4 Core, complete all as specified and directyed at site. ( Note-Excavationandearth workwill be measuredandpaid seperately under relevant item. )
73All as per item No. 72 above but size 120 Sqmm 3.5 core to 240 Sq mm 3.5 core, complete all as specified and directyed at site.
74Supply and laying ,jointing and testingXLPE insulated extrudedPVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 10 Sqmm 4 core.
75All as per item No 74 above butsize 120 Sqmm 3.5 core, complete all as specified and directyed at site.
76All as per item No 74 above butsize 150 Sqmm 3.5 core, complete all as specified and directyed at site.
77All as per item No 74 above butsize 240 Sqmm 3.5 core, complete all as specified and directyed at site.
78Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected.
79Supply & laying brick for protection of cable sub class "B"laid dry flat across the cable with width equal to the length of whole brickscomplete all as specified and ditected.
80Material and Labour for boring, holes for inserting of 40/50/80 mm bore GI pope under the road/hard standing or any other location not less than 1200 mm deep complete all as specified and ditected.
81M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
82M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
83M & L GI pipe 80 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.
84Takingdown existing old defectiveLTPanel / FP Box by disconnectiing its all elecetrical connections and by dismentelling foundation complete all as specified and directed at site by Engr-in-Charge.
85Supply, install, connect & testing cubical outdoor type factory made double door , powder coated LT bus bar feeder pillar box having alluminium bus bar suitable for 200 amps 3 phase and neutral arrangement of size 500mm x 500mm x 200mm with MCCB 4 pole 100 A as incoming including provision of LED Indicating lamps (RYB) 01 set of 3. complete weather proof and vermin proof conforming to IP-54 made out of 3.15 mm thick CRCA sheet including provisions for ventilation and cable termination alley &two Nos suitable size of aluminum strip for body earthingall as per IS.It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45 mtrs above GL and 0.30 mtrs below ground including required PCC for foundation complete all as specified and directed.
86Supplying,installation,testing,commissioning of LT panel board 3 phase 4 wire system indoor type factory made free standing floor mountingwith suitable clamp dust and vermin proof cubical type interlocking arangement ( IP- 55 protection) fabricated with 2 mm thick CRCA sheet with Anti corrosion coating & finally polyester powder coated of finite green fuly compartment with providing with suitable size of aluminum strip all as specified for the following.(a) Incomming :-(i) Incoming ACB with Microprocessor Release IPR E of 800 Amps, 4 Pole, 415 Volt with repturing capacity of 50 KA - 1 No.(ii) Digital type Amp Meter 0-800 Amp with CT"s 03 Nos.(iii) Digital type voltmeter 0-500 Volts -01 No.(iv) Indicating lamps (RYB) 01 set of 3. (v) Copper bus bar rating 1200 Amps 3 phase neutral-01 set.(vi) Chamber for incoming & outgoing cable.(b) Outgoing :- (i)MCCB 400 AMPS 4 pole 415 Vollts 36 KA -01 No.(ii) MCCB 250 AMPS 4 pole 415 Vollts 36 KA -02 No.(iii) MCCB 200 AMPS 4 pole 415 Vollts 36 KA -03 No.
87Supplying,installation,testing,commissioning ofoutdoor type LT panel board 3 phase 4 wire system ,415 Volts ,50 Hzfactory made free standing , floor mounting dust and vermin proof cubical type interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finally powder coate painting having thickness not less than 100 micronsof finite grey, fully compartmentalizedwith providing two Nos suitable size of aluminum strip for body earthingand including suitable PCC foundation all as specified for the following :- (a) Incomming :-(ii)MCCB 125 AMPS 4 pole 415 Vollts 36KA -01 No.(iii) Digital type amp meter 0-200 Amp with CT"s 03 Nos.(iv) Digital type voltmeter 0-500 Volts -01 No.(v) Indicating lamps (RYB) 01 set of 3.(vi) Aluminium bus bar rating 200 Amps 3 phase neutral-01 set (vii) Chamber for incoming & outgoing cable.(b) Outgoing :-(i)MCCB 100 AMPS 25 KA 415 Volts 4 pole -1 No. (ii)MCCB 63 AMPS 16 KA 415 Volts 4 pole -02 No.(iii)MCB TPN 32AMPS C curve 415 Volts-01 No.(iv)Din rail multifunction digitaltimer switch Make GIC model 67DDTO-01 Nos.(v)Power contactor 4 pole 40 amps Make L & T Cat No. MCX 12 model No CS97014-01 Nos.
88M&L earthing complete with galvanised steel earth plate 600X600X6.3 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of32X6 mmas earthing leadsby means of bolts, nuts, check nuts and washers besideWelding / brazing at all joints as shown on drawings and including excavation, earth work.GI pipe light grade40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common saltPCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -Iand conected to earth test point including testing complete all as secified and directed.