}

Tender For Construction Of Administrative Building Including Welfare Facility Service At Greenfield Electronics Manufacturing Cluster (Emc) In Tuem Village Of Pernem Taluka. – (Sub Work- Supply, Installation, Testing And Commissioning Of Electric Traction, pernem-Goa

Info Tech Corporation Of Goa Limited has published Tender For Construction Of Administrative Building Including Welfare Facility Service At Greenfield Electronics Manufacturing Cluster (Emc) In Tuem Village Of Pernem Taluka. – (Sub Work- Supply, Installation, Testing And Commissioning Of Electric Traction. Submission Date for this Tender is 29-04-2024. Building Work Tenders in pernem Goa. Bidders can get complete Tender details and download the document.




Tender Notice

42928711
Corrigendum : Tender For Construction Of Administrative Building Including Welfare Facility Service At Greenfield Electronics Manufacturing Cluster (Emc) In Tuem Village Of Pernem Taluka. – (Sub Work- Supply, Installation, Testing And Commissioning Of Electric Traction
Open Tender
Indian
Goa
pernem
29-04-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Construction of Administrative Building including Welfare facility service at Greenfield Electronics Manufacturing Cluster (EMC) in Tuem Village of Pernem Taluka. – (Sub work- Supply, Installation, Testing and Commissioning of Electric Traction Passenger Lift)” , Sitc Of Electric Traction Passenger Lift With · Rated Capacity :- 8 Passenger/544Kg · Floors :-G+1 Floor (2 Stops/2 Landings) · Travel :-3 To 4.2 Mtrs · Location Of Lift Machine:- Mr/Mrl · Rated Speed :- 1.0 Mps Vs · Car/Landing Doorclear Opening Of 800 Mm Wide X 2000 Mm High · Clear Carsize Of1100mm Wide X 1300Mm Deep X2250mm High · Lift Shaft Available Having Clear Size Of 1900Mm Wide X 1700Mm Deep, 1600Mm Pit Depth, 4000Mm Overhead. · Doors Type :- Copo/Topo Doors With Frame Made From Ss 304 Gradesolid(Non-Cladded) Sheet Of 1.5Mm Thick In Hairline Finish For Car And All Landing Doors With Ss Door Architraves/Frames The Lift Doors Shall Have Minimum 1 Hour Fire Rating (With Submission Of Necessary Valid Test Certificate Issued By Nabl Accredited Or Independent Test Laboratory). · Lift Car Enclosure Made From Ss 304 Grade Solid (Non-Cladded) Sheet Of 1.5Mm, Thick With Hairline Finish With Frame Made From Ms Girders, Bracing Of Adequate Size With Minimum Safety Factor Of 5, With Toe Guard Apron, With Necessary False Ceiling With Adequate Led Lights, Blower/Fan For Ventilation & Ss Chequered Plate Flooring, Handrails, Mirror, Emergency Light Etc. The Lift Car Interior Design Shall Be Done As Per The Directions Of Engineer In Charge. , · Cop With Ss Face Plate Having Metallic Push Buttons With Braille Code & Luminous Indicator Around Button With Fpi, Scrolling Up/Dn Led Indicator & With / Without Attendant Key Switch, Owd With Audio-Visual Alarm, Vas In Marathi, Hindi & English With Intercom System With Telephone Instrument In Lift Car, Lmr & Fcc/Ground Floor. · Lop With Ss Face Plate Having Recess/Surface Push Button Box For All Landings With Scrolling Up/Dn Led Indicator Having Metallic Push Buttons With Braille Code & Luminous Indicator Around Button With Cpi, Lift Car Arrival & Next Travel Direction Audio-Visual Indication At All Landings. , · Lift Controller Based On Microprocessor/ Plc With Vvvf Drive Having Closed Loop Control System, With Ibms Compatible Having Necessary Port. The Controller Shall Have Necessary Protections Such As Overcurrent, Overvoltage, Over Speed, Overheat For All Devices Including Lift Motor And Travel Direction Protection, Protection For Phase Loss At Input Or Output Etc. Various Operation Modes Such As Maintenance, Change Direction By Attendant, Full Load Bypass, Vip Call Operation, Self Levelling Operation, Call Cancel Facility, Auto Return To Home Landing, Fireman Evacuation Operation, Earthquake Operation, Door Open/Close Operation From Cop Etc. The System Can Record Information For Minimum 30 Latest Faults, With Real-Time Clock Management And Handheld Keypad With Lcd Screen For View And Setting Of Parameters. The Control Panel Duly Wired With Proper Size & Strength, Copper Wire For Power & Control Circuit, With Provision For Addition Of Floor/Control Card & Allied Accessories Control Panel Having Enclosure Of 1.5Mm Crca Sheet With Powder Coating With Ip54 Protection Class. , · Ard Complete With Necessary Smf Vrla Batteries. · Fireman Controller Having Fireman Switch At Fire Landing. · Cctv Surveillance System Comprises Of 2 Nos Minimum 2.0 Mp Fhd Ip Based Vandal Proof Dome Camera In Lift Car & In Lmr/Inside Lift Shaft Top Aimed On Lift Machinery & Controller With Nvr Kept In Lmr/Fcc With Hdr Data Backup Min. 90 Days With Min. 18” Fhd Tv Monitor, To Be Kept In Fcc/Lmr As Directed By Engineer In Charge. · Lift Machine Of Gearless Pmsm Of Suitable Kw With Duty Cycle Of Minimum 120 Starts/Hr (With Submission Of Necessary Valid Test Certificate Issued By Nabl Accredited Or Independent Test Laboratory), With Traction Pulley, Osg, Electromagnetic Brakes, Entire Assembly Mounted On Adequate Size Girders Duly Fixed On Lmr Floor/ Shaft Walls Complete With Main/Diverter Traction Sheaves, Suspension Wire Ropes/Belts Of Adequate Size & Strength. , · Other Mechanical Parts Such As T Section Adequate Size Guide Rails For Car & Counter Weight With Brackets Fasteners, Counter Weight Frame With Necessary Blocks, Buffers With Necessary Support Arrangement, Ms Pit Ladder Etc. Erected With Necessary Steel Work. · Minor Civil Work Such As Alteration Work If Any Necessary For Erection Of Landing Door Frames And Its Accessories E.G. Sill, Header, Hole Pass Etc Complete With Plaster Finish, Civil Work For Erection Buffers, Erection Of Lift Machinery, Adequate Size Core Cuts If Required & Scaffolding For Erecting Guide Rails, Providing And Fixing Steel Girders/Rcc Work Having Adequate Strength For Mounting And Hoisting Lift Machine Etc. Complete As Per Specification No. Lft. · General: - Job Includes Entire Procedure Of Obtaining All Necessary Erection Permissions & License To Work The Lift From Electrical Inspector(Lifts) With Submission To The Engineer In Charge. · The Above Rate Includes Fully Comprehensive Amc For One Year From The Date Of Commissioning. Add Ons For Lift Traveling Above 1St Floor , For Lift Travelling Up To Six Floors Or At A Speed Of 1.0 Mps, Add As Below, For Lift Having 800Mm Wide X 2000Mm High Clear Entrance In 1.5Mm Thick Ss 304 Grade Solid (Non-Cladded) Landing Door [Two Panel], This Includes All Necessary Accessories Like Lops With Up/Dn Buttons-Arrows-Indicators, Extension Of Guide Rails, Shaft Wiring With Trunking, Traveling Cables, Main Hoisting Ropes/Belts, & Osg Rope Landing Doors With All Accessories Etc. Necessary For The Normal Safe Functioning Of Lift Installation Complete. , For Full Collective Control System, Add As Below. For Lift Travelling Above First Floor & Up To Sixth Floor , Supply Of4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Completeas Required. (5) 4 X 16 Sq. Mm. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct,Etc.Complete As Required , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing. The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled Withhighly Crystalline Conductiveand Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode (A) 3 Metres Length Electrode. , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Supplying And Laying 25 Mm X 5 Mm Copperstripin 40 Mm Dia Gi Pipefromearth Electrode As Required , Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface R In Recess For Coneections Etc. As Required

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-04-2024
2 15-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-04-2024
3 22-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-04-2024

Key Value

Document Fees
INR 1500 /-
EMD
INR 27680.0 /-
Tender Value
INR 13.83 Lakhs /-

Attachment

FileName File Description File Size
8ce41e03-391d-4221-8b76-668265ce17a7.html Tender Notice 0 KB
BOQ_15573.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Tendernotice_2.pdf Tender Document 0 KB
Tendernotice_3.pdf Tender Document 0 KB
Tendernotice_4.pdf Tender Document 0 KB
Tendernotice_5.pdf Tender Document 0 KB
Tendernotice_6.pdf Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail