Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKSSec.1.0 Earth work Providing material, labour, machinery for Excavation of foundation upto 1.5 m depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting. |
| 2 | Providing material, labour for Excavation of foundation from1.5 mtto3.0 mt depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting. |
| 3 | Providing material, labour for Excavation of foundation from3 mtto5.0 mt depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting. |
| 4 | Providing material, labour for Excavation of foundation from5.0 mtto7.0 mt depth including sorting outandstacking of useful materials anddisposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth and back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting. |
| 5 | Providing material, labour for Disposing off the un-used excavated stuff (black cotton soil, debries, of above items for all lead and lift/ depth outside the campus at non objectional place or as directed by Engineer in charge. |
| 6 | Providing material, labour for Fillingin plinth with sand under floors including watering ramming, consolidating and dressing etc complete as directed by Engineer in charge. |
| 7 | Providing material and labour for injecting Chemical emulsion for PRE - CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier on the top surface of plinth filling, inside junction of wall and floor, on top of damp proof course (DPC) or on masonry at level of plinth filling as per IS 6313 (Part-2)-1981 using chemical like chloropyripos emulsifiable,Biflex TC, lindane (IS 8944-1978) 20EC mixed with water in 1:19 ratio (1 liter chemical : 19 liters of water). The emulsion shall mentioned below, all as per specification and directions of Engineer-in-charge.Plinth area in plan at GF shall only be measured (for akk below specified steps) and paid. A guarantee bond of 10 years shall be furnished. A1) Bottom surface and the sides of the excavation made for masonry foundations at the rate of 4 liters/sqm (wherever applicable)A2) At the rate of 7.5 liter/ sqm to the backfill at the depth of 500mm below the original ground level. The soil in the immediate contact with the vertical surfaceof RCC column/ Masonry shall be treated.B) Top surface of the plinth filling including damp proof courses at the rate of 5 liter/sqm of internal plinth area etc. complete.C) At the rate of 7.5 liter/ sqm to the internalvertical surface from original Ground level to top of the earth filled in the plinth.D) At the rate of 7.5 liter/ sqm to the externalvertical surfacebelow finished Ground level to the full depth of the filling complete.E) 1 liter / linear meter along the junction of wall and floor at all stages. |
| 8 | Providing material and labour for laying Plain cement concrete M15 in Foundation and Plinth including cost of formwork, compacting, finishing, curing etc complete for all level, all height/ depth as directed by engineer in charge. |
| 9 | Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding (with 18 SWG -1.22 mm GI wire) and placing in position complete for all floors, all levels, all heights/ depth complete as per drawings, specifications and direction of Engineer in Charge. |
| 10 | Providing material and labour for laying controlled cement concrete M-20 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for allelements, all floors, any heights/ depths, any lead and liftincluding cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge. |
| 11 | Providing material and labour for laying controlled cement concrete M-25 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for allelements, all floors, any heights/ depths, any lead and liftincluding cost of formwork, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge. |
| 12 | Providing material and labour for laying in position Ready Mixed M-20 grade concrete for reinforced cement conctere Grade slab work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 13 | Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere Columns, Pillars posts, Mullion, strutswork, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 14 | Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere Beams, Lintels, Runner, Girders, pile-cap work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 15 | Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere Slabs, staircase, landing, shelves, chhaja, cantilever work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 16 | Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 17 | Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere Foundations, footings,Base of columnsandMass concrete work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 18 | Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere Columns, Pillars posts, struts work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 19 | Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctereany type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cementitious level as per latest IS 456 shall be maintained) manufactured in fully automatic batching plant and transported to site of work in transit mixer for all lead having continuous agitated mixer, as per mix design for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 20 | Providing material and labour for laying in position Ready Mixed M-35 grade concrete for reinforced cement conctere for Columns, Pillars posts, struts work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 21 | Providing material and labour for laying in position Ready Mixed M-35 grade concrete for reinforced cement conctere for any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for allelements, all floors, any heights/depths, any lead and liftas directed by Engineer Incharge. |
| 22 | Providing material and labour for fixing in position PVC pipe sleeves of 75mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location). |
| 23 | Providing material and labour for fixing in position PVC pipe sleeves of 160mm Diameter - 6Kg/cm2 and length as per design for following diameters for services wherever pipes pass through walls/ slabs/ beam in mtrs length. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while concreting, and burrs removed before laying etc complete for all floors, all height as directed by engineer in charge. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Pipe sleve shall be remoed before water proofing or grouting (at rain water down take location). |
| 24 | Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 51 to77mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. |
| 25 | Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 77 to102mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. |
| 26 | Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 102 to125mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. |
| 27 | Providing material and labour for wet drilling accurate and clean holes of specified diameter in RCC walls, slabs, beam or any other RCC memberwithout vibration by core cutting (diamond drilling) holes from 125 to152mm dia machine including scafolding, safety majors, disposing the debris, cleaning for all floors, all height etc compete as directed by engineer in charge. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorised approved agency. |
| 28 | Chemical Anchor:Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 10mm and depth 150mm as per manufacturer/ structural consultant\"s specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. |
| 29 | Chemical Anchor:Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 12mm and depth 180mm as per manufacturer/ structural consultant\"s specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. |
| 30 | Chemical Anchor:Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 16mm and depth 240mm as per manufacturer/ structural consultant\"s specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item.Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge. |
| 31 | Sec.3.0 Centering & Form worksProviding material and labour for formwork for exposed concrete surfaces (Only extra addition cost on normal shutering) (vertical or horizontal surface) in smooth finish, desired pattern and size as per drawing and specifications, including rendering with white cement and grey cement, using laminated shuttering plywood, for vertical and steel or laminated plywood shuttering for horizontal surfaces for all types RCC elements like slabs, walls, columns, beams, folded staircase (all sides), sill, coping, lintels, jambs, beam hunching, vertical fins, pardi etc. including neat cleaning the exposed concrete surface, as directed by the engineer-in-charge. In case of round window opening in exposed RCC wall, for payment of expose shuttering opening cutout shall not be deducted (both side). Rate shall be applicable for all floors, all levels, all places and all shapes. The contractor shall submit shuttering pattern including tie-rod hole position based on architectural conceptual drawings. (Same kind of shuttering material should be only used for standard and residual sizes.) |
| 32 | Sec.4.0 Masonry worksProviding material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in foundation and plinth in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. |
| 33 | Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg/SqCm in Cement Mortar 1:5 (1- Cement : 5 -fine sand) in superstructure above plinth levelfor all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. |
| 34 | Providing material and labour for laying Halfbrickmasonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1-Cement : 4 -coarse sand ) in superstructure for all Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge. |
| 35 | Providing material and labour for laying of hollow concrete block masonry for jali work madeout from M20 grade 200mm thick hollow block of different size to cerate a pattern as per drawing confirming to IS 2185 Part I grade A (7.0), shape of hollow part shall be round, square or rectangle. Jali wall shall be constructed in cement mortar 1:2 (1 cement : 2 coarse sand) by providing2 no of 6 mm dia. GI bar at each layer vertically as well as horizontally. GI wire/ rod shall be anchored in adjoining surface with quick fix chemical including roughening, cleaning, fixing and finishing/ rendering in grey and white cement sand mortar 1:1 in the line and level and in patternincluding finishing, curing at all heights with necessary scaffolding etc complete as per the drawing and direction of Engineer in charge.Note: Payment should as per actual area of jali made out of hollow block, no deduction of hollow gap of block should be consider for payment. |
| 36 | Providing material and labour for fixing 190mmx 190 mm x 80 mmglass bricks of approved make and design with white CM 1:2 ( 1 white cement : 2 sand). Two numbers of 5 mm thick GI wires to be passed through PVC spacers in each joint horizontal as well as vertical by drilling holes in surrounding surface (brick or RCC) and filling the same with Hilti or equivalent chemical (rebarring). The PVC concealed spacer (with provision for passing the 2 no. GI wires in horizontal and vertical direction) shall be provided to maintain grooves/spaces for GI wire and white cement mortar at the junction of two glass bricks including curing. The sample of the glass brick shall be got approved by Architect. The glass bricks shall be fixed with placing GI wires vertically as well as horizontally after passing through the spacer and having minimum lap length of + 200 mm as per the site conditions at all the places, all heights, all level and in all shapes, etc. complete, as per drawing and as directed byEngineer-in-charge. Joints along the periphery of glass bricks shall be filled with approved make and color weather silicone sealant of DOW corning 789 or equivalent. |
| 37 | SEC:5 Doors and Windows workALUMINIUM WORKS -Providing material and labour for fixing in position frames/ shutter for any type of aluminium work for any type of door, window, partition, fixed louvers, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors/ all levels/ all heights/ all shapes/ all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections which are visible shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame;2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatiblemicrowave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI HRDUGT or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of sectionfor connecting style and horizontal rails; 6) providing and fixing packing at every 600mm c/c of average 6 mm compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required but excluding. 1) necessary hardware; 2) Glazing or Infill material. |
| 38 | Providing material and labour for fixing 6mm thick Clear Toughen Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid. |
| 39 | Providing material and labour for fixing 6mm thick Wired Glass including 1 mm thick ss wire @ every 1 cm horizontal & verticalof any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing with EPDM quality rubber/ silicon sealant/ structural sealant on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Architect. Actual installed quantity shall be measured and paid. Rate shall be inclusive of all type of wastage. |
| 40 | Providing material and labour for fixing 6mm thick Compact Sheet of any size, any shape, any color, any texture of approved make and as per approved sample(approved by architect). Compact sheet shall be fixed in aluminium frame and shutter work with necessary cutting of sheet, single side, double side coloured as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ adhesive tape/ screwing on the periphery of the sheet as per the required thickness etc. complete at all floors/ all levels/ all heights as per the drawing & directed by Engineer in charge. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity shall be measured and paid. |
| 41 | Providing material and labour for fixing 35mm thick solid core flush type door shutter (non decorative) of approved make and as per approved sample (Battens should be chemically treated & kiln seasoned & binding agent should be phenol phormaldihide) and of required size, as per approved drawing, design and direction. The rate shall also include external lipping of maximum size 10 mm X 42 mm thickness for single shutter and 25 mm x 42mm thickness for double shutter of seasoned teak wood equivalent to best quality 1st class teak all around and 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ oil and water finished polishing or lacquer polishing to lipping, all as per approved drawing, for all floor, all level all height etc. complete as directed by Engineer-in-charge. Measurement including lipping shall be considered for payment. Necessary hardware like hinges, pivot, handle, tower bolts, locks etc shall be separately measured and paid in the relevant tender items. |
| 42 | Providing material and labour for fixing 25mm thick solid core flush type door shutter (non decorative) of approved make and as per approved sample (Battens should be chemically treated & kiln seasoned & binding agent should be phenol phormaldihide) and of required size, as per approved drawing, design and direction. The rate shall also include external lipping of maximum size 10 mm X 42 mm thickness for single shutter and 25 mm x 42mm thickness for double shutter of seasoned teak wood equivalent to best quality 1st class teak all around and 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ oil and water finished polishing or lacquer polishing to lipping, all as per approved drawing, for all floor, all level all height etc. complete as directed by Engineer-in-charge. Measurement including lipping shall be considered for payment. Necessary hardware like hinges, pivot, handle, tower bolts, locks etc shall be separately measured and paid in the relevant tender items. |
| 43 | Providing material and labour for fixing 1 mm thick Laminate sheet of approved make and shade on Non decorative flush door, panelling work, fixed partition, any ply surface etc with necessary nails, screws, adhesives as per drawings and as per approved sample. Laminate shall be either glossy, matt, Swede or any type of texture finish. The rate shall be for all heights, all floors, all places etc complete as directed by engineer in charge.Actual laid area shall be measured and paid without considering any westage. |
| 44 | Providing material and labour for fixing vision panel made out of 5mm thick clear toughen glass of any shape any size in all type/ thickness of flush doors shutter. Glass shall be fixed with teak wood lipping (Lacquer polished of approved make and shade) on both side the door of required size as shown in drawing and direction of Engineer-In-Charge. Rate shall be includes the cost of cutting door, provision of glass with both side polished lipping, making good for all floor, all level, all height etc complete. The actual installed area of vision panel shall be measured for payment. |
| 45 | Providing material and labour for fixing SS-304 gradebutt hinge of 100 x 75 x 3 mm - with ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge. |
| 46 | Providing material and labour for fixingMortise lock of approved make having 72mm centre to centre, 55mm Backset 20mm Square forend and 60/ 70mm standard Europrofile Pin Cylinder with both side key /one side key - one side knob operation and SS 304 grade hollow tubular pipe pair of Mortise handle of 22mm dia 150mm long with a pair of SS 304 Escutcheons (key hole plate) for wooden /aluminium/ metal doors with necessary ss phillips head screws etc complete for all floor, all height, all level as per approved sample as directed by engineern in charge. The lock shall be with 3 keys. |
| 47 | Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 200 mm long x 19mm dia made out of satin (brush) finish hollow pipe of 1.5mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved makewith necessary screws etc. complete forwooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle should be perfect center to center as below specified. |
| 48 | Providing material and labour for fixing chromium plated brass/ SS 304 grade handles 150mm long D shape rod handle of approved make with both end bracket with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 49 | Providing material and labour for fixing of SS 304 brush finish 250mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 50 | Providing material and labour for fixing 250mm long (minimum rod size shall be 14mm and 110mm hanging handle) \"J\" type SS 304 brush finish Aldrop (sliding bolt) of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 51 | Providing & fixing 200mm long (minimum rod size shall be 12mm and 50mm hanging handle) SS 304 brush finish Tadi (sliding bolt with out locking hole) of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 52 | Providing material and labour for Fixing SS 304 satin finish 100mm longBaby Latch including Bracket of 35 mm x 38mm, minimum Weight 198 grm with necessary SS Screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 53 | Providing material and labour for fixing SS 304 brush finish solid Door Stopper with magnet, fixed type, wall mounted (square/ round) of approved make with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 54 | Providing material and labour for fixing SS 304 brush finish solid Door bufer with pvc base, wall mounted (square/ round) of approved make with necessary screws etc. complete as approved by Engineer-in-charge in Charge. |
| 55 | Providing material and labour for fixingAluminium powder coated butt hinges of required capacity of approved make for casement window/ door (europrofile) with necessary accessories, screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 56 | Providing material and labour forfixing powder coated inbuilt flush handle (without lock) of approved make of required capacity including all required accessories like nib, counter plate etc as per approved manufacturer recomendatation for aluminium sliding window with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 57 | Providing material and labour forfixingadjustable/ fixedTeflon roller bearing set with reinforced nylon casing of approved make (twin or single wheel according to weight and size) for sliding window/door as per drawing etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge. |
| 58 | Sec.7.0 Plastering & Pointing worksProviding material and labour for laying 10mm thick mala cement plaster in single coat onceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Ground Floor to Ninth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. |
| 59 | Providing material and labour for laying 20 mm thickinternal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished upto Basement Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. |
| 60 | Providing material and labour for laying 20 mm thickinternal/ external double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished for Ground Floor to Ninth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge. |
| 61 | Providing material and labour for fixing G.I. hexagonal chickenmesh of size 20mm x 20mm of 22 gauge at junction of concrete and brick work or between different materials after making \"V\" grove between two different material surface and filled with rich cement mortar and@ 100mm on each side of surfaces including necessary \"U\" nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge. |
| 62 | Sec.8.0 Waterproofing worksProviding material and labour for laying average 18mm thick double coat (water proof) smooth/ wired finish cement plaster on sides of masonry work/ block wall/ RCC wall, 12 mm thk first coat in CM 1:3 (1 cement : 3 coarse sand) by spraying , second coat of 6 mm of CM 1:3 (1 cement : 3 fine sand)and mixing Integral waterproofing liquid admixture for mortarin recommended proportions in both coats,finishing the surface wired finish/ smooth finish with a floating coat of neat cement slurry at 2.75 Kg/ sqm to receive the tiles for all floors, all shapes and all height including hacking to RCC surface, scaffolding, curing etc. complete for all floor, all height as directed by engineer-in-charge. Cement slurry admixed withIntegral waterproofing liquid admixture for mortar in recommended proportions is to be applied before each coat and final finishing coat. |
| 63 | Providing material and labour for laying integral cement based water proofing treatment (India type brick bat) including preparation of surface as required for treatment of roofs, balconies, terraces etc with average thickness of 120 mm and minimum thickness at khurra as 65 mm and consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with wired finish to receive china mosaic flooring.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge for all height all level. |
| 64 | Toilet waterproofingProviding material and labour for carrying out waterproofing treatment to sound concrete surface of toilets, sunken slabs, corridors, wet areas etc. after proper surface preparation to remove loose dust, dirt etc., repairing of cracks (if any) using polymer modified mortar, carry out cementitious injection grouting at leakage points modified with Plasticized Expandive Grout Admixture @ 225 gms per bag of cement, carry out 50 mm thick cement mortar (1:3) vatta/ corner modified with Styrene Butadine Polymer bonding agentat dosage of 2.5 Ltr per 50kg cement, Pre-dampening concrete surface, mixing and application of two coats of Elastomeric Polymer modified cementitious waterproofing coating by incorporating alkali resistance 45 gsm glass fibremesh between 1st and 2nd coat using suitable brush or roller as per coverage etc. complete for all floor al height all levelas per manufacturer’s specification and as directed by engineer in charge.Cured Polymer modified cementitious waterproofing coating shall comply with ASTM D4060, ASTM D4541, ASTM D638,ASTM C836 and possess below properties: Mixed density: 1.68 g/cc, Adhesion to concrete-> 1 N/mm2, Non-toxic, Static crack accommodation-1 mmWater proofing system shall be executed by only approved applicator of approved brand and under strictly supervision of technical fellow of manufacturer. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper inapproved proforma. |
| 65 | Hole Packing treatment on service line Providing material and labour for applying total packing treatment on any type of pipes comes into water proofing area for all floor, all height as directed by engineer in charge as follows :Preparing the inside surface of core and Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of styrene- butadiene based polymer coating using Styrene Butadine Polymer bonding agentto enhance adhesion between the packing material and other surfaces. Packing the gap using non shrink cement polymer based grout using Non-shrink cementitious grout upto the surface of the bore whilst the bonding agent is in tacky state before application of water proofing treatment. Treatment shall be executed by same agency with same manufacturer\"s product. Warranty includes in water proofing item. |
| 66 | Sec.9.0 Flooring worksProviding material and labour for laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white cement, curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. |
| 67 | Providing material and labour for laying Ceramic tiles 6mm thick in skrting, risers of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry,curing etc complete for all floors any heights, any lead and lift as directed by Engineer In charge. |
| 68 | Providing material and labour for laying 25mm thick (average) polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge. |
| 69 | Providing material and labour for laying polished kota stone slab 25mm thick in risers of steps, skirting, Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift etc complete as directed by Engineer In charge. |
| 70 | Providing material and labour for laying 25 mm thick mirror polished machine cut kota stone slab of size upto 2.0mt length with uniform thickness for flooring, skirting, dedo, tread, riser, window jambs, coping over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including champhering in same gauge of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be chmphered with same thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. |
| 71 | Providing material and labour for laying 24\" x 24\" vitrified 8 to 10 mm thick tile (Antiskid and matt finish) flooring, otta, Skirting over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing, curing & cleaning the surface for all floors all heights, all lead and lift etc complete as directed by Engineer Incharge. Rate shall be inclusive of base palster. |
| 72 | Providing material and labour for laying 8 to 10mm thick,double charged Vitrified tiles (of any shade glossy or satin finsh) ofsize upto 24\" x 24\"of approved make, shade and finish as approved by Architect/ EIC (Glossy)for all floors/ any height/ any levels etc in skirting, dado, risers of steps, jambs as per drawings. Wall tile is to be fixed over 10 to 12 mm thick wired finish plaster in cement mortar 1:3 (1 cement : 3 coarse sand) and average 6mm thick 1:1 cement sand mortar including pointing in white cement mixed with pigment of matching shade etc including curing, cleaning with mild oxalic acid, maintaining till handling over at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Rate shall be inclusive of base palster. |
| 73 | Providing material and labour for fixing 18mm thick mirror polish Granite of uniform size and colour for treads and risers of stair, on coping etc size 1000mm to 2000 mm long, of approved shade, including necessary machine - cut edges (uniform thickness) rounded edges, as per design in required sizes and shapes over 20 mm (average) thick bedding of cement mortar 1:6 (1 cement: 6 coarse sand) laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC etc complete for all floors any heights, any lead and lift as per approved sample by Architect, drawings and instruction of EIC. The rate shall be inclusive of making rebates of 10x10mm for forming the grooves between treads and risers with polishing inside the groove. The rate includes machine cut edges of uniform thickness, rounding of edges, champhering and mirror polishing of edges and maintaing upto hand over the project. |
| 74 | Providing material and labour for laying sandwich platform comprising of a) Sandwich of 18 mm thick single side polish Granite of approved size, shade and sample on top and 30 mm thickpolished kota in bottom with 25mm thick cement mortar (1:4) in between b) At centre vertical sandwich supports of 30 mm thick two kota stone on sides and 20mm CM (1:4) in between and at both end walls vertical supports of 18 mm thick double side granite. c) 75 mm raised platform at bottom with kota on top and 50mm CM (1:4) at bottom, kota stone skirting as per design and approved sample. The rate includes rounding, champhering and mirror polishing of edges, facias of granite, MS support including necessary bonding adhesive (if required). Rate shall be also inclusive of curing, making holes & cutouts for sink, wash basin, Piller tap/ Bib tap at all floors all height etc complete as directed by Engineer Incharge. (Only plan area shall be measured & paid for). Rate shall be included all kota & granite mentioned in above. |
| 75 | Providing material and labour forlayingbrokenchina mosaic flooringfor terrace using 12 mm to 20 mmbroken pieces ofglazed tiles to be laid over cement mortar 1:3 to plain or slope andtobe temperedtobring mortarcremeout uptosurface using white cement including rounding off junctions and extending them upto 15 cm along the wall, curing, clearing with water and oxalic acid etc for all level, all height as directed by engineerin charge. |
| 76 | Grouting the joints of flooring tilesfor average size up to 600mm x 600mmhaving joints of 3 to 5 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade from approved make (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Sample shall be approved before procurement of material. |
| 77 | Providing material and labour for laying Cement Mortar for additional floor bedding in Cement Mortar 1:6(1-Cement: 6 - coarse sand) including curing etc for all floor, all level all height. Additional bedding thickness shall be as per drawing and as directed by engineer in charge. |
| 78 | Sec.10.0 Structural steel worksProviding material and labour for, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats,Bars , Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame work etc. including straightening, cutting, bending, bolting and welding the members all as per approved shop drawings and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding ; Machine drilling of holes for joining/ anchoring; dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth, 1 coat zinc chromate yellow oxideprimer and2 coat of enamel paintof approved make shade of paint over all the surfaces of the steel sections.The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by engineer in charge. (Standard measurements will be paid for as actual cut length used at site) |
| 79 | Providing material and labour for, Fabricating and fixing SS hand rail / railing, gratings, corner guard of 304 grade made out of round, square or rectangle hollow sections, angle, plate, flat, rod/bar in satin/ brushfinish including supporting fittings made out of SS 304 grade solid rods, flanges, compatible SS anchor fastener (mechanical or chemical) of Hilti or equivalent as per manufacturer\"s specifications, SS connecting bolts of required size with washers, SS base plate, lath work, argon arc welding, buffing, bending and bends as per the detail drawing with best (high) quality finish & as per the a sample approved by Architect and as directed by engineer-in-charge. Rate shall be inclusive of all material, labour wastage and for all floors/ all levels/ all heights. Railing shall be measured in KG & paid accordingly. Actual installed length of member shall be measured and no extra shall be paid for consumable fasteners. |
| 80 | SS water troughProviding material and labour for, Fabricating and fixing SS 304 grade water trough of size 300mm x 450mm with 300mm high SS sheet cladding (dedo) made out of 1.2mm thick sheet and required size of angle, flat etc in satin/ brushfinish including supporting fittings made out of SS 304 grade solid rods, flats, anges, compatible SS anchor fastener (mechanical or chemical) as per manufacturer\"s specifications, SS supporting arrangement, latth work, argon arc weldingbending and bends as per the detail drawing with best (high) quality finish & as per the a sample approved by Architect and as directed by engineer-in-charge. Rate shall be inclusive of all material, labour and wastage for all floor, all height, all level. Water trough shall be measured in Rmt. Installed length shall be measered. Contractor shall prepare shop drawing based on concept drawing ant get approved before execution. |
| 81 | Providing material and labour for applying Distempeing (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall and ceiling surfaces to give an even shade, over and including a priming coat with alkali resistanceprimer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth etc complete for all floors, all heights, all level as directed by Engineer Incharge. |
| 82 | Providing material and labour for applying (Synthetic) Plastic emulsion paint (minimum 2 coats) having VOC (Volatile Organic Compound) content less than 50 gm/ltr on newly dry interior plastered surface including ceiling, roof etc.at all heights/ all levels/ all surfaces to give an even shade including applying required coats (min two coats) of white cement based putty after thoughly brushing the surfaces free from mortar dropping and other foreign matter. Preparing the surface even and sand papered smooth, after applying every coat of putty complete. Priming coat of alkali resistant cement primer (water or solvent based) is to be applied over prepared smooth surface (undulation free) etc. complete as directed by engineer-in-charge. Sample to be approved before starting of the work by Architect/ EIC. The rate shall include the cost of filler for filling the cracks on surface, thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter, scaffolding etc. as directed by engineer in charge. |
| 83 | Providing material and labour for applying Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete for all floors, all heights, all level as directed by Engineer Incharge. |
| 84 | Providing material and labour for applying external finish of average 2 to 2.5mm thick acrylic polymer based texture and pattern with standard tool and applicator as specified by manufacturer on exterior surfaces at all heights including scaffolding to give even shades including thoroughly brushing the surfaces free from mortar droping and other foreign matter and sand paper smoothed as per the manufacture specifications etc. complete for all floor, all height, all leveland up to the satisfaction of Engineer in-charge/ Architect. The rate includes making of grooves, pattas and finishing as directed by Engineer in charge. Paint shall be measured and paid in seperate tender item. (Item should be executed by approved applicator only.) |
| 85 | Sec.12.0 Roofing worksProviding material and labour for fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weightcalcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture of size 595 X 595 x 15 mm to be laid on true horizontal level suspendedinter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/ partitions on a perimeter wall with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weightcalcium silicate ceiling tiles in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint,as per specifications, drawings and as directed by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of 0.50 (Minimum) and 0.75 NRC for Globe, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation at all floors, any heights, any lead and lift etc complete. as directed by Engineer Incharge. |
| 86 | Providing & Fixing M/F Suspended 12.5mm Plain Gypsum Board which includes GI Perimeter Channelis fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centres. GI Ceiling Angle is suspended at up to suitable height as per sight conditions by fixing it to the GI soffit clit with Soffit Cleat and Rawl Plug creating 1220mm x 1220mm grid. GI Intermediate channel is fixed to the GI Ceiling Angle with 2 Nos of 4.2x13 GI metal to metal screw. The GI Ceiling Section is then fixed to the GI Intermediate Channel with the help of Connecting Clip and in direction perpendicular to the Intermediate channel at 457mm c/c. Single layer of 12.5mm tapered edge Plain Gypsum Board (Confirming to IS 2095-Part-I, 2011) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing Compound & Joint Paper tape. The contractor should prepare shop drawings based on the concept drawing and get it approved by the Engineer-in-charge. After approval of drawings, the contractor shall prepare the sample based on the drawing and get it approved by the Engineer-in-Charge before execution. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, making grooves between wall & board or as per drawing for all floor, all level, allheight etc as directed by Engineer in charge.Area of cutouts shall not be deducted and no extra payment shall be considered for additional sections provided. Only plan area shall be considered for payment. |
| 87 | Metal False Ceiling:Providing material and labour for, fixing and laying ofplain finish GI metal ceiling system consisting of600 mm x 600mm Clip-in with double pip self-leveling feature and special tabs to allow removal of tile to enable plenum access withplain visual consisting of 600mm x 600 mm clip in tiles of galvanized steel in 0.5 mm thicknesswith bevel edge in Global white colorprecoated with primer coat at the rear side with Light Reflectance > 60%and load carrying capacity of 14 KG/ SQM. The T-sections have a galvanizing of 90 grams/sqm and passed through 500 hrs of salt test. Tiles would have fire performance of Class A2-s1.d0 as per EN13501. Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers. The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm Main carriers (spring tee bars) shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a hanger.Use connector to splice two pieces of main carriers. Tiles should be clipped in between two carriers (spring tee bars) from below. Perimeter trims to be of wall angles of white color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp.Tile, grid system and suspention system shall be of same make and as per approved sample. The Tile & Grid system used together should carry a 10 year warrantee. Installation will be done by approved installer only. The shop drawing, specification and sample mock of miniumum 5 Sqmt with framework shall be approved by Architect/ EIC. Rate shall also include cost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/ template where ever required. The rate shall be in Sqmtfor all floors/ all heights/ all levels including scaffolding etc. as directed by Engioneer in charge. |
| 88 | Sec.15.0 General Development and Road worksProviding and laying rubble soling in plinth and sub-base of road, compacted thickness specified as following, using specified size of hard stones for average 150mm thick soling, filling, covering and leveling the surface with a layer of earth after filling the voids (upto 25%) with sand, smaller sized black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of stone/metals or stone chips, including watering, ramming well and compacting or consolidating each layer by static roller/ vibratory roller of required capacity as directed by Engineer-in charge. |
| 89 | Providing material and labour for fixing Ductile iron manhole frame and cover/ grating/ chamber cover of approved make and type. Man hole cover shall be any type (hinged type, double sealed or recess type), any shape (square/ rectangle/ square frame with round cover) any grade (light duty/ medium duty/ heavy duty) of required loading capacity having double sealed system as per manufacturing standard BS EN-124, with proper lifting arrangement, black bituminous coating, includingfixing in CC and finishing etc complete as directed by engineer in charge. Cover shall be as per drawing and as per approved sample. Recess manhole cover depth shall be according to pavement/ finish as per drawing. |
| 90 | 2.0 PLUMBING WORKSPHE-01.00 Water Supply Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator working on operated by float type level controller and manually, VOLTAGE 220V AC. C) 65mm dia. |
| 91 | Providing & fixing on line Electro-magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted adjacent to flow sensor with Modbus data output to the BMS Rack located in the Plumbing Plant Room. Device to monitor the Total Flow, Flow rate / velocity, etc. Including wiring from sensor to transmitter. Complete with all type of Plumbing & Electrical connections, accessories,wiring, & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. The complete installation would be as per the approval and direction of the Engineer-in-charge. Electronic Flow Sensor & Transmitter – Media Clear Liquids; Line Size - as mentioned below; Display - 8 Digit for Flow Rate & 8 Digit for Flow Totalized – 16 x 2 Backlit Alphanumeric LCD; MOC: Body – SS with PU Coating; Flange: SS 316; Flow Tube: SS 304; Liner: Hard Rubber; Electrical Wire of 3 core x 1.5 Sq. mm of approved make with 6 amp 3 pin plug, Protection Class: IP 68; Earthing as per manufacturers\" standards; Accuracy:0.5%; complete. (B) 65mm diameter |
| 92 | Providing and fixing Gun metal check or non-return fullway wheel valve.(A) 15mm dia. |
| 93 | Providing and fixing Gun metal check or non-return fullway wheel valve.(B) 20mm dia. |
| 94 | Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (e) 50mm dia nominal bore. |
| 95 | Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (f) 65mm dia nominal bore. |
| 96 | Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Ashirvad / Equivalent. a) 15 mm nominal bore |
| 97 | Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Ashirvad / Equivalent. b) 20 mm nominal bore |
| 98 | Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Ashirvad / Equivalent. c) 25 mm nominal bore |
| 99 | Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Ashirvad / Equivalent. d) 32 mm nominal bore |
| 100 | Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Ashirvad / Equivalent. e) 40 mm nominal bore |
| 101 | Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Ashirvad / Equivalent. f) 50 mm nominal bore |
| 102 | Providing and fixing PVC Ball valves with S.S. 304 ball valve on EPDM seat, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge.Make: Astral / Ashirvad / Equivalent. g) 65 mm nominal bore |
| 103 | Supplying & erecting approved make Automatic liquid level controller 6A.as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank. |
| 104 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [A] 15 mm. |
| 105 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [B] 20 mm. |
| 106 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [C] 25 mm. |
| 107 | Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [D] 32mm. |
| 108 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (i) 15 mm nominal outer dia pipes |
| 109 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (ii) 20 mm nominal outer dia pipes |
| 110 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (iii) 25 mm nominal outer dia pipes |
| 111 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (iv) 32 mm nominal outer dia pipes |
| 112 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (v) 40 mm nominal outer dia pipes |
| 113 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (vi) 50 mm nominal outer dia pipes |
| 114 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (vii) 65 mm nominal outer dia pipes |
| 115 | Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class \"O\" IMO fire performance ) of the following diameter and thickness overpipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class \"O\" insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water.15 mm dia (09 mm thickness of insulation) |
| 116 | 20 mm dia (09 mm thickness of insulation) |
| 117 | 25 mm dia (13 mm thickness of insulation) |
| 118 | 32 mm dia (13 mm thickness of insulation) |
| 119 | 40 mm dia (13 mm thickness of insulation) |
| 120 | 50 mm dia (13 mm thickness of insulation) |
| 121 | 65 mm dia (13 mm thickness of insulation) |
| 122 | PHE-02.00 Sanitary Installations:Providing and Fixing vitreous china extended wall mount water closet (EWC) as per IS: 2556 (Part 2) of size 565 x 360 x 350mm (P Type) including seat and cover as per IS: 2548 of approved make and quality, and as approved by Engineer-in-charge, including all necessary fittings and accessories, complete. (II) Type 2 - Hindware - Flora - Model # 20098 / Equivalent |
| 123 | Providing & fixing C.P. brass Concealed type flush valve (Metropole Flush Valve) with, 25 mm dia C.P. flush pipe with clamp and adapter, rubber joint, C.P. brass wall flange, elbow complete with all other accessories. Make: Jaquar - FLV-1085N or Equivalent |
| 124 | Providing and fixing ABS Chrome plated Brass Hand Shower(Health Faucet) ofapproved make and quality and as approved by Engineer - In - Charge, including 8 mm dia, 1 Meter long Flexible tube & wall hook including cutting and making good the walls wherever required complete as per directions of the Engineer-in-charge. Make: Jaquar - ALD-573GA or Equivalent of the same make. |
| 125 | Providing & fixing Divyang toilet set with European Closet (P Trap) & wall mount wash basin & all divyang requirements with dual flush tank, seat & lead (heavy duty) including C.I. Brackets, C.P. brass hinges,M.S. / C.I. painted brackets, 32mm CP waste Coupling, 32mm size CP bottle trap, CP brass Spatula Faucet, etc. all Internal fittings complete with S.S grab rails etc. rubberbuffers, C.P nuts, bolts etc making holes in walls & floors, & finishing for ready to use.The rate includes all necessary connection charges as per product detail to the satisfaction and as directed by the Engineer-in-charge. Make: Hindware - Matrix - 70002 Set of WC, Wash Basin, Grab Bars; Make: Jaquar - Spatula Faucet - FLR-5093N; Make: WaterTech / Prayag - PTMT wastecoupling & bottle trap. Divyang Set: Make - Hindware - Matrix Set - 70002; Long Handle Basin Cock: Make: Jaquar - Florentine - FLR-5031 N / Equivalent. |
| 126 | Providing and fixing white vitreous China overcounter washbasin with single hole for pillar tap fitted over the counter with required and appropriate silicon sealant and making good the same, including pillar tap, braided hose, 32mm waste coupling, 32mm CP brass bottle trap, complete as per the direction and approval of the Engineer in charge. Size: 380 mm x 380mm x 130mm depth. Wash Basin - Make: Hindware - Inox - #91066; Pillar Cock with neck aerator - Make: Cera - F3002103; Waste Couling - Make: Cera - F8050301; Bottle Trap - Make: Cera - F8060301 |
| 127 | Providing and fixing Flat Back Large Urinal of approved make and quality including conecting the Urinal with waste pipe , pressmatic flush valve, spreader, including fixing to wall with C.P. brass screws, rawl plugs, etc. complete. Make: Hindware - Flat Back Large of size 610 x 410 x 380mm - 60002 / Equivalent. |
| 128 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 17.10.2 - Kitchen Sink without drain board Size: 610 x 510 mm bowl depth 200mm |
| 129 | Providing and fixing C.P. brass Side single lever sink mixer with swinging spout (table mounted) with 450mm long braided hoses, of approved make and quality, and as approved by the Engineer-in-charge,and conforming toManufacturers Standards. Make: Jaquar - Florentine - FLR-5179B / Equivalent. |
| 130 | Providing and fixing C.P. brass waste for washbasin or sink. (A)32mmdia. |
| 131 | Providing and fixing C.P. brass waste for washbasin or sink. (B)40mm dia. |
| 132 | Providing and fixing C.P. brass shower rose with 15mm or 20mm inlet.(A) 100mm dia. Each |
| 133 | Providing and fixing C.P. brass Shower arm for over head shower of approved make and quality, and as approved by the Engineer-in-charge,and conforming toManufacturers Standards. a) Size: Casted 190mm long light body round shape for wall mountedshower rose with flange, of approved make and as per the direction of the Engineer-in-charge. Make: Jaquar - SHA - 483 / Equivalent. |
| 134 | Providing and fixing C.P. brass Wall Mixer with provision for overhead shower with 115mm Long Bend pipe on upper side, connecting legs & wall flanges, complete as per approved make and as directed by the Engineer-in-charge. Make: Jaquar - Fusion - FUS 29273UPR / Equivalent. |
| 135 | Providing and fixing C.P. brass towel rail complete with C.P. brass brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size. |
| 136 | Providing and fixing toilet paper holder.(A) C.P. Brass |
| 137 | Providing and fixing of 15mm nominal bore CP Brass Angle valve confirming to IS: 8931, for wash basins, water coolers, geyser points, etc of approved quality and as approved by and directed by the Engineer-in-charge. |
| 138 | Providing and Fixing 15 mm dia. Wall mounted type CP brass pressmatic bib cock with Auto Closing System with Built-in Control Cock With Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. Make: Jaquar-PRS-043 / Equivalent. |
| 139 | Providing and fixing 15 mm diameter Pillar Cock with lift tye operating knob & base flange of approved make and quality and as approved by Engineer - In - Charge, including 600 mm long braided hose with M10X1 Nipple, 15mm nut, O-ring & rubber washer, including cutting and making good the counters wherever required complete as per directions of the Engineer-in-charge. Make: Jaquar - Pillar Cock - Florentine - FLR - 5015; Braide Hose Pipe - ALD-801B / Equivalent. |
| 140 | Providing and Fixing in position CP brass Pressmatic Urinal Flush Valve Auto-closing system with built in Control Cock and Wall flange of approved or equivalent make, including 15mm diameter x 200mm long S.S. pipe connection with Urinal and spreader, and including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. Make: Self Closing pressmatic angle cock: Cera - F9020203; Spreader - F8070201 / Equivalent. |
| 141 | Providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin. |
| 142 | Providing and Fixing SS Liquid Soap Dispenser of approved make and quality, and as approved by the Engineer-in-charge, including all necessary materials required for fixing. All completeas per directions of the Engineer-in-charge. Make; Jaquar - ACN-1137N / Equivalent |
| 143 | Providing, fixing, jointing, testing and commissioning ofHeavy class SS grating of grade SS 304 of approved make and quality, and as approved by the Engineer, weighing not less than 150 gms. including setting in floor with white cement to match with floor finish as per requirement complete as per directions ofEngineer in charge. Type 1 - Size 129mm x 129mm Square Matt finish with Cockroach trap consisting of 104mm diameter (101mm) perforated top cover, 77mm Ø x 70mm high Cockroach Trap ideal for 100mm drain pipe with floor trap cover as specified in approved make and quality. Make: Chilly - Square Gypsy: Model No: CCT-SG-129 / Equivalent. |
| 144 | Providing, fixing, jointing, testing and commissioning ofHeavy class SS grating of grade SS 304 of approved make and quality, and as approved by the Engineer, weighing not less than 150 gms. including setting in floor with white cement to match with floor finish as per requirement complete as per directions ofEngineer in charge. Type 2 - Size 150mm x 150mm Square Matt finish with Cockroach trap consisting of100mm diameter solid top cover, 77mm Ø x 70mm high Cockroach Trap ideal for 100mm drain pipe with floor trap cover as specified in approved make and quality. (For Urinal only) Make: Chilly - Lifestyle Square : Model No: CCTL-S-150 / Equivalent. |
| 145 | Providing and fixing ball cock of approved. quality as directed.(B) Abonite(ii) 50mm dia. |
| 146 | Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less than 35Kg. |
| 147 | Providing and fixing Structured Wall U.P.V.C. non pressurized wastewater piping conforming to IS: 13592, and fittings as per IS: 14735, including all fittings like bends, tees, reducers, Y joints, couplers, etc with rubber inserts of 3mm thickness complete, joined by manufacturer\"s recommended rubber lubricant, including cutting the pipes to required lenghts, including fixing the pipes with MS Split clamps with EPDM rubber lining of required diameter at 1.20 M spacing center to center, GI threaded rods, anchor fasteners, drilling of holes in ceiling slabs and walls as required, and installations at all levels and heights, as directed by the Engineer-in-Charge. Make: Ashirvad / Astral / Prince / Equivalent.f) 200mm dia pipe |
| 148 | Providing and fixing of self cleansing P Trap, in Structured Wall UPVC non pressurized wastewater piping as per IS: 14735, of size 110mm x110mm with solvent cement welding, complete, including cost of cutting and making good the walls and floors. Make: Astral / Ashirvad / Prince. |
| 149 | Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. |
| 150 | Providing, laying and jointing in true line and level 75 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line,pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral / Ashirvad / Prince. |
| 151 | Providing, laying and jointing in true line and level 50 diametre P.V.C (6kg/cm2) conforming to IS 4985 with single socket, & fittings of approved make for drainage system pipe line,pipe shall be jointed with each other with appropriate solvent cement, pipe shall be shall be concealed in walls as directed, including necessary fittings such as bends, shoes etc. including testing of pipes and joints, including cost of all materials. Make: Astral / Ashirvad / Prince. |
| 152 | Providing, laying and jointing in true line and level 40 diametre PVC (6kg/cm2) conforming to IS 4985 with single socket, & fittings of approved make for drainage system pipe line,pipe shall be jointed with appropriate solvent cement, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints, including cost of all materials. Make: Astral / Ashirvad / Prince. |
| 153 | Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 75 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls. |
| 154 | Providingand fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe. Make: Astral / Ashirvad / Prince. |
| 155 | Providing and fixing on wall face unplasticized-PVC rain water pipes conforming to IS : 13592 (Type A) including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single Socketed Pipes (110mm dia pipes) |
| 156 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised-PVC rain water pipes conforming to IS : 13592 (Type A), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe Bend - 110mm dia pipe |
| 157 | Construction of Recharge pit (5 pits) - Constructing brick masonry recharge pit having wall thickness as per structure engineer, of size 3.0M diameter x 5.0M depth internal dimension, R.C.C. top slab of size 3.0M diameter x 0.20M thickness having adequate reinforcements and concrete mix as per structure engineer, circular foundation concrete elow the walls only of size (internal diameter - 2.80M; outer diameter - 4.82M: area - 12.09 sqm) 1.01M width x 0.20M thickness as per structure engineer, with inside plaster 15 mm thick with cement mortar 1 : 3 finished smooth with a floating coat of neat cement on walls etc. complete. |
| 158 | PHE 04.00 EquipmentsSupply, Fixing, testing and commissioning of MNRE approved MNRE approved Flat Plate Collector type solar hot water system with ISI marked and IEE approved Electrically operated Air to Water Heat Pump of the following capacities:The scope for Solar FPC includes 120 Litre each thermosyphon system Flat Plate Collectors having insolation surface area 2.2 Sq. Mtrs., including selective coating on the inner surface of the absorption plate with thermal insulation between the plate and the housing box, face of the box to have high transmittance glass plate as per IS: 12933 of Bureau of Indian Standards, circulation pump, D.M. Water Tank, all gaskets and gromets, M.S. vertical stand and base plate with two coats of primer and two coats of rubber paint, bolts and nuts for fastening with the Cement Concrete Base blocks, interconnecting Heavy Duty G.I. pipes with nitrile rubber insulation and 22 gauge Aluminum Sheet Cladding, pipe supports and clamps, gate valves, check valves, thermister valves, steam release valves, flange blanks / plugs, etc complete as per direction of the Engineer-in-charge. The scope also include provding and fixingof Electrically Operated Air-to-Water Heat Pump Hot Water System of capacity as mentioned below, comprising of helical rotary twin compressors with direct drive motor (the compressor speed shall not exceed 3000 RPM) with shell and tube type plain tube chiller as well as shell & insulated tube type integrally finned condenser, at working efficiency of minimum 80%, having heating capacity up to 60 degree centigrade, The heat pump package shall include vibration mountings, copper refrigerant piping as per the latest applicable B.I.S. codes and standards, full refrigerant charge using CFC free gas, system control wiring and accessories, installed on a fabricated mild steel base frame assembled to form a compact assembly,complete with microprocesssor based control panel comprising of adaptive controls, indication lights, Star-Delta starters, over-load and under-loadprotection, TPN isolator for termination of incoming power cable, necessary control wiring, disconnect switch, grooved (Victaulic couplings at inlet and outlet of both heat exchangers, DP switches for both heat exchangers, vibration isolation arrangements electrical panel with starter for Heat Pumps, testing of all systems post installation at Minimum Wet Bulb Temperature of 17.7 degree Celsius in January to deliver hot water at 55 degree Celsius. The scope also includes commissioning of the entire system, commissioning certificate in the name of the Engineer-in-charge, etc. complete as per manufacturing standards and to the complete satisfaction of the Engineer-in-charge.The scope includes insulated M.S. storage tanks with ceramic lining of capacity as mentioned below, including making inlet, outlet heavy gauge C.P. connection, temperature guages (at inlet and outlet of storage tank). The Storage Tanks duly painted with two coats of Red-Oxide and having PUF / Rockwool insulation, outer cladding of 22 guage Aluminum Sheet, control valves at inlet and outlet of Water tank, M.S. supports for the tanks with M.S. base plate, bolts and nuts for fastening the stands and support to Cement concrete blocks, testing the tanks and the entire hot water system at a constant water pressure of 5.0 Bar (50 Mtrs) each, testing of the entire system for a constant flow of hot water at 55 degree Celcius during peak winter when the Wet Bulb Temperature is 17.7 degree Celcius. Make: Benchmark / Jaquar / Equivalent.For Hostel BuildingTotal System Capacity: 12000 LPDSolar HWG: 6000 LPD with 6000 Ltr capacity storage tank. 50 x 120 ltr each Solar Panels, gate valves, steam release valves, isolation valves, interconnecting G.I. \"C\" Class pipes, with nitrile rubber insulation and aluminium cladding, pressure guage, temperature gauge, thermostats, etc complete. Heat Pump HWS: 6000 LPD with 6000 Ltr capacity storage tank. 2 pumps of 20 kW (output capacity; connected load 5 kW each), electrical starter panels, level sensors, temperature sensors, thermostat, temperature gauges, pressure gauge, interconnecting G.I. \"C\" class pipes with nitrile rubber cladding and aluminium cladding, complete. All interconnecting pipes, fittings, valves, pipe supports, etc complete. |
| 159 | R.O. Plant: Hostel BlockSupply, Installation, Testing and Commissioning of Reverse Osmosis water treatment plant having raw water feed pump, Chlorine Dosing System, Anti-scalant System, filters, Micro-cartridge filters, R.O. membranes, or any of these in a combination to provide scaling free water to all buildings within the campus, including centrifugal multistage water pump (1 working + 1 standby), connected plumbing work, control panel for auto cutoff, auto on, auto regeneration, auto rinse and auto filter mode (1 working + 1 standby) with IP55 protection with all necessary equipment, piping and connected activities as per specification and operating conditions as mentioned by manufacturer or as directed by engineer in charge. System Capacity: RO - 400 LPH (Permeate) ; Feed - 1.4 m3/hr @ 30% recovery |
| 160 | Hydro-pneumatic System - for all buildings (terrace):Supplying and erecting Fully Automatic hydro pneumatic booster system with cast iron housing Enclosure class IP44 minimum , with built in PTO motor protection and stainless steel impeller pump, pump modelGRUNDFOS CMB 5-46 series or equivalent with 24 Liter hydro pneumatic pressurized tank capacity8 m3/hr,Rated head :40 mtr, motor rating : 1.5 H.P. includes pressure switches, Non Return Valve, Pressure Gauge, 5 way Brass connector, with necessary Plumbing work of 25mm dia suction and delivery pipe which includes all required size of pipes, Joints valves, Bypass valve, labor all accessories required for installation of pressure pump ( Foundation work and base stand cost included) |
| 161 | WATER COOLERS:Providing & Erecting full SS Body (SS 304) Split type water cooler having storage capacity 160 to 175 Ltr.(Tank SS 304) & Cooling capacity 150 ltr. Per hour @ an ambient temp of 350 C.The outlet temp. of the water should drop by 150C within a hour,The water cooler should be comprising of hermetically sealed Reciprocating compressor with R134A, fan motor, Copper Condensing unit with company fabricated Outdoor Unit water tank surrounded by evaporating coil, thermostats, relay etc.complete with necessary copper tube & Insulation, M.S Chanel Stand with Painting for water tank & M.S. Powder Coated Stand for Outdoor unit with Installation.With DPELCB and 4 Way DB Box with accessory Three core Cord for connection. |
| 162 | WATER COOLERS:Supplying and erecting water filter cum purifier with ultra violate technology. (Aquaguard / waterdoc model or equivalent symphony/ crystal/videocon model) |
| 163 | ELW 03.00 Substation Equipment and substaion AuxiliarySupplying& Erecting Rubber mat 1.1 KV grade ISI marked 1000 x 1000 x 4 mm size. |
| 164 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.MAIN PANEL_STUDENT HOSTELAs per Single line diagram |
| 165 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.TYPICAL FLOOR PANEL_STUDENT HOSTELAs per Single line diagram |
| 166 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.EMERGENCY PANEL_STUDENT HOSTELAs per Single line diagram |
| 167 | Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels withpowder coated fabricated fromCRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect.GF PANEL_STUDENT HOSTELAs per Single line diagram |
| 168 | ELW 06.00 Distribution BoardSupplying, assembling, grouting, levelling, installation,Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement.Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 8 SPMCB as outgoing per phase (i.e. 12 way TPN D.B.) with 12 way PPI kit |
| 169 | Supplying, assembling, grouting, levelling, installation,Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement.Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) with 8 way PPI kit |
| 170 | SPN Distribution Board :Supplying, erecting, testing and commissioning ofSPN D.B. with space for DPELMCB as incoming and 12 SPMCB as outgoing per phase (i.e. 16 way SPN D.B. |
| 171 | upplying, erecting, testing and commissioning ofSPN D.B. with space for DPELMCB as incoming and 4 SPMCB as outgoing per phase (i.e. 8 way SPN D.B.) |
| 172 | MCB \"s and its AccessoriesSupplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in boards as specified in 8.1, 8.2.Miniature circuit breaker single pole 6A to 25A. suitable to operate on 240V. A.C. system and having breaking capacity 10 KA to be erected in existing box. Confirming to IS 8828 / 1996 with ISI Mark. Cat III |
| 173 | SITC of 6A / 10A / 16A / 20A / 25A DP RCBO (RCCB+MCB) (30mA) |
| 174 | SITC of 32 / 40 A DP RCBO(RCCB+MCB) (30mA) |
| 175 | SITC of 63 A DP RCBO(RCCB+MCB) (30mA) |
| 176 | SITC of 6 to 32 A FP MCB, Cat III |
| 177 | SITC of 40 A FP MCB, Cat III |
| 178 | SITC of 63 A FP MCB, Cat III |
| 179 | SITC of Sheet steel metal enclouser for FP MCB |
| 180 | Surge Protection Devices (SPD)Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards1.2KV Protection level FP, Class \"s\", (Imax-15KA, 8/20µS) Cat 003954 |
| 181 | Surge Protection Devices (SPD)Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards1.2KV Protection level DP, Class \"s\", (Imax-15KA, 8/20µS)Cat 003974 |
| 182 | SITC of Blank Plates |
| 183 | Caution Board :SITC of Caution boards of size 150 x 150 mm. to be supplied & fixed on the D.B. |
| 184 | ELW 07.00 MV CablingCABLESSupply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of AluminumConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.70 Sq.mm x 3.5C Al. Cable |
| 185 | Supply, testingand Laying and commissioning ofXLPEsteel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.16 Sq.mm x 4C CU. Cable |
| 186 | Supply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of CopperConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.10 Sq.mm x 4C CU. Cable |
| 187 | Supply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of CopperConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.6 Sq.mm x 4c CU. Cable |
| 188 | Supply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of CopperConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.6 Sq.mm x 3c CU. Cable |
| 189 | Supply, testingand Laying and commissioning of XLPEsteel wire/flat armoured cable of 1100 V grade of AluminumConductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.2.5 Sq.mm x 3c Al. Cable |
| 190 | ELW 08.00 Cable TerminationSupplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:70 Sq.mm x3.5C Al. Cable |
| 191 | Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:16 Sq.mm x4C CU. Cable |
| 192 | Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:10 Sq.mm x4C CU. Cable |
| 193 | Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:6 Sq.mm x4C CU. Cable |
| 194 | Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:6 Sq.mm x 3c CU. Cable |
| 195 | Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:2.5 Sq.mm x 3c CU. Cable |
| 196 | ELW 09.00 Cable TraySupply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :150 x 100 made out of 2 mm thick ladder type |
| 197 | Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :150 x 50 made out of 2 mm thick ladder type |
| 198 | Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :300 x 100 made out of 2 mm thick ladder type |
| 199 | Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :450 x 100 made out of 2 mm thick ladder type |
| 200 | Supplying , fabricating and installation of various sizesclamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc. |
| 201 | ELW 10.00 Internal WiringWITH MODULAR TYPE SWITCHESWiring of points to be done in open/concealed manner in 25 mm dia medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit .The circuit shall be laid in 25/40 mm dia medium guage rigid PVC FRLS pipe.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board.The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as underFor Light Points /fan point/ wall fan / 6A 3 Pin Plug-DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth- SB to on board Point - 1.5 sqmm for Phase & Neutral & EarthFor 6A Plug point.- 1.5 sqmm for Phase, Neutral & EarthFor 6/10/16A general purpose plug point- 2.5 sqmm for Phase, Neutral & 1.5 sqmm EarthFor 16A plug point for A/C and Geyser- 4 Sqmm for Phase, Neutral & 2.5 sqmm EarthFor 20/32A plug point- 6 sqmm for Phases, Neutral & 4 sqmm EarthNo zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted.One light point controlled by one single way 6 A switch. |
| 202 | Loop light point to be controlled from same switch.(Looping from first point) |
| 203 | One light point controlled by two, two way 6 A switch |
| 204 | One ceiling fan outlet point controlled by one6 A switch and hum free electronic type step regulator and cast iron fan box. |
| 205 | One 6 A x 5 pin 250 Volt universal socket outlet point controlled by one 6 A switch located on switch board. |
| 206 | 6 A x 5 pin 250 Volt universal switched socket outlet point at convenient location. |
| 207 | 6/16 A x 250 V switch socketpoint on one switch box with 2.5 sqmm flexible wires and phase and neutral and 1.5 sq nm flexible Cu. wire as earth wire. The rate should include conduiting upto DB. |
| 208 | 6/16A x 250 Volt switched socket outlet point for body storagewith 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire. |
| 209 | -Do- as above but switch and socket at different location |
| 210 | Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location. |
| 211 | Bell point controlled by Bell push switch withBuzzer / bell of approved make. |
| 212 | SITC computer power supply point with 2 nos of 6 amp 5 pin socket with 1 no. of 6/16 Amp. socket with 1 no 16 ASwitch with indicator & wiring of computer point will be done through2 nos.of 2.5 sq. mm Cu. wires as phase & Neutral and 1 nos. of 1.5 sq.mm.as earth wire. .( This cost includes the wiring from DB to Computer point.) |
| 213 | 20 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 2 module legrand make Cat no.056669 or equivalent but without cost of wiring and piping. |
| 214 | 32 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56669 or equivalent but without cost of wiring and piping. |
| 215 | 32 A x 415 V plug & socket with interlocked switched socket, FP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56674 or equivalent but without cost of wiring and piping. |
| 216 | METAL CLAD SWITCJH SOCKETSITC of Metal Clad Switch Socket with 10A SP MCB (2P+E) |
| 217 | SITC of Metal Clad Switch Socket with 20A DP MCB (2P+E) |
| 218 | SITC of Metal Clad Switch Socket with 20A FP ELMCB (2P+E) |
| 219 | SITC of Metal Clad Switch Socket with 32A FP ELMCB (P+E) |
| 220 | Supplying and Providing mains with 4 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire withISI approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories. |
| 221 | Supplying and Layingmains with 2 nos. of 4 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. |
| 222 | Supplying and Layingmains with 2 nos. of 2.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories. |
| 223 | ELW 11.00Light Fixtures and FansSupplying and erecting, testing and commissioning of 21W4\" FeetLEDSurface/Suspended Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash S, complete with all hanging & mounting accessories.(Minimum 2400 Lumens) |
| 224 | Supplying and erecting, testing and commissioning of 42W7\"/8\" FeetLEDHanging Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent makeSlash S, complete with all hanging & mounting accessories.(Minimum 4200 Lumens) |
| 225 | Supplying and erecting, testing and commissioning of 1x21W 1200mm LEDSurfaceMounted indoor Linear BrightBattern Lights Fittings -Make Phillips or equilavent( BN021) |
| 226 | Supplying and erecting, testing and commissioning of 1x10W 600mm LEDSurfaceMounted indoor Linear Bright Battern Lights Fittings -Make Phillips or equilavent ( BN021) |
| 227 | Supplying and erecting, testing and commissioning of 27WCircularLEDRecessed Mounted indoorLights Fittings with High Efficency TranslucenceDiffuser -MakeWipro or equilavent ( Halo,CDSL-11R033HP57) |
| 228 | Supplying and erecting, testing and commissioning of 13W to 17WCircularLEDRecessed Mounted indoorLights Fittings with High Efficency TranslucenceDiffuser -MakeWipro or equilavent (CRDL11-R013HP57) |
| 229 | Supplying and erecting, testing and commissioning of LEDSurfaceMountedDown Lighter 18W LED - Philips Make SM251 LED20S. |
| 230 | Supplying and erecting, testing and commissioning of LEDSurfaceMountedDown Lighter 12w LED - Philips Make SM251 LED12S. |
| 231 | Supplying and erecting, testing and commissioning of26WLEDSurfaceMountedDown Lighter-MakeWipro or equilavent( Halo,CRDL-11S033HP57) |
| 232 | Supply,Installation, testing and commissioning following sizes ceiling Fans with 5 step electronic regulator. 36\" Dia Sweep Ceiling Fanas per approved colour & equivalent to crompton make high speed Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2, 3 core flexible wire with earthing [ Make shall be approved by Engineer in charge] |
| 233 | Supplying and erecting 19/20mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/O. 2 flat 3 core flexible wire with ear thing. |
| 234 | Supplying and erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM. (A)200 mm dai 900 RPM (CAT-2) |
| 235 | SITC of suitable M.S. louver shutter of the Exhaust fan. |
| 236 | Supplying & erecting in earthpit of minimum bore dia. 225mm sizeapproved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipeshaving Outer pipedia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applicationswith chamber and heavy duty cover.(approvedmake OEM has to submit test certificate including value of earth resistane of installation.-Length of Pipe : 3 Mtrs.-Back filling Compound :2 nosBags of 25 Kg |
| 237 | Earth wire/strips :Supply and laying cu. earthing required size stripsfor interconnecting the earthing stations, panels, DB\"s etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with :a) Fixing accessories.b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes.25 x 3 mm/ 32X6mm / 50x6mm CU. strip/ 38x6 Cu earth link |
| 238 | SITCof No.8 gauge bare cu. earth wire |
| 239 | ELW 13.00 MiscellaneousPVC PIPESSupplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 25 mm dia with GI pulling wire. |
| 240 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 32 mm dia with GI pulling wire. |
| 241 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 40 mm dia. |
| 242 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 50 mm dia. |
| 243 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 75 mm dia. |
| 244 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 90 mm dia. |
| 245 | Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 110 mm dia. |
| 246 | Supplying and laying following sizes DWC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed.Heavy gauge pipe in Open / Concealed mannerminimum 200 mm inner dia. |
| 247 | Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.25mm |
| 248 | Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.32mm |
| 249 | SITC of2 compatement 100 mm x 50 mm wall trunking/race way with cover and all accessories made out of PVC . |
| 250 | Fire StopperSITC of Equivalent to Hilti make Hilti Mineral Wool Board SystemProviding Fire resistant board system with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The fire resistant board system shall comprise of a mineral wool board coated with an ablative coating CP 670 at 0.7mm dft. The mineral wool board should be of min.160 kg/m3 density. All contact surfaces and cavities shall be sealed with a joint filler CP 606. The service lines could be of various types like electrical cables trays, metal pipes, etc. The product shall be age tested for as per Dafstb and DIBT standards. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 38 g/l as per LEED 2009. The product shall bear the UL and FM approval logo on the packing where applicable. |
| 251 | SITC of Equivalent to Hilti make CP 636 Firestop MortarProviding & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc. The product shall be age tested as per Dafstb and DIBT standards. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable. |
| 252 | SITC of Equivalent to Hilti make CP 620 Expanding SealProviding Fire expanding foam with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls made of concrete/ masonry or Gypsum for passing service shafts. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall be tested for providing a sound insualtion of 50 db when tested in accordance with ASTM E 90. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested and approved by third party agencies such as UL & FM. The product should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable. |
| 253 | SITC of Equivalent to Hilti make CP 678 Cable coatingProvide and apply intumescent based coating on cables/ cable tray along the horizontal runs at every 10 mtr in case of horizontal runs, every 5m in case of vertical runs and tee-offs shall be provided at intervals of 30mtr. The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992). The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 60 g/l as per LEED 2009. The coating should not have any de-rating effect on the cable and should support relevant certificates for these attributes. |
| 254 | ELW Sec 15.00 Lighitning ProtectionSITCof 8 mm dia solid Aluminium Conductor for roof top mesh gridand tested as per IEC 62561- 2conducted in the Govt. accreditedthirty party laboratory to meet the requirement of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu. conductor, Expansion piece with connectors at every 20 mtr distance, Aluminium straight Splicer to connect conductors. All Accessoriesshould be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test &6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230 |
| 255 | Supply, installation, testing and commissioning of test link complete with inter connections between aluminium round conductor & GI strip or GI strip to GI strip all fixing accessories etcrequiredfor complete installation, Complete in all respect with all required accessories. |
| 256 | SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia 3000 mm long- Cold Galvanized |
| 257 | Supplying, installation, testing and commissioning of 3 metre Vertical Airterminal of dia 16-10 mm withComplete Support of wall clamp selected as per angle of protection chart to meet the requirement of IS/IEC 62305 .Tested for Electrical ,Mechanical and Chemical as per IEC 62561. VAT 3 with mounting accessories on parapet wall surface(includes - VAT 3 + interception tip + 2 no of wall clamps+connecting point & stainless Steel Earthing stud with connector & D-Clamp for interconnecting ELPS and structral down conductors)Equivalent to CAPE Type :VATW 3 (Article No. 404 430) |
| 258 | Down Conductor SystemSITC of 10 mm MS Round Solid Conductor having smooth surface Should be tested and use exclusively for lightning protection (Vertical Riser/Down Conductor which shall be concealed in Column) to meet the requirement of IS IEC 62305 With Accessories - Earthing stud of dimension SS-75mm OD plate with 10mm dia tail connector used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. (For Interconnecting the Column and the Terrace AL Conductor / Strip/Flat), SS Cross Connector to connect Earth fixing point to vertical raiser/Down conductor, SS Straight Splicer at every 4 Mtr to connect MS conductor in column, Bonding /Rebar Clamp at every 3 mtr suitable for interconnecting round conductor with reinforcement inside the concrete for structural earthing system, SS connector -To connect external conductor 8- 10 mm with earth fixing point. All Accessoriesshould be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test &6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230 |
| 259 | SITC of Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Complete in all respect with all required accessories. |
| 260 | ELW 16.00 UPSSupplyingand erecting approved make online Un-interruptible Power Supply system with IGBT Based rectifer andInverter & sealed maintenance free batteries. Single phase Input and Single Phase output with Inbuilt Isolation transformer with 0.8 load power factor with battery, overunder voltage output with over load & short circuit protection equipment.The system housed in CRC sheet duly powder coated paint with following capacity & with Following size of batteries for 30 Min Backup (Minimum 10080 VAh) 10 KVA UPS with 42 AH, 20 Nos. Battery Certification : BIS |
| 261 | SOLAR PLANTDesign, Engineering, Supply, Installation, Testing & Commissioning of 20 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with allaccessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc. |
| 262 | ELV WORKSSec.1.0 Telephone and Data NetworkingProviding and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm |
| 263 | Telephone / Data Networking CablingSupplying & erecting approved make LAN cable of following size in existing pipe as per direction.[C] CAT - 6 |
| 264 | Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge.(8) Modem Jack for Computer Open RJ-45.Cat. III. |
| 265 | SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded as per technical specification etc. as required. |
| 266 | SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U\" Snag less |
| 267 | SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U\" Snag less |
| 268 | Providing & erecting Fiber Optic LC style fully loaded Patch Panel (FOPP), 19\" Rack Mount with following nos. of OS2 9/125µ Pigtails as per ISO/IEC-11801-OS2 Pigtails with LC Type Connectors Shall have all accessories including coupler plates pre loaded with duplex LC couplers (OS2), pigtails for terminating fibers on the FOPP Pigtail Attenuation =0.3dB measured measured against reference connector Return Loss = 45dB, in mated condition Pigtail Cable Information – Outer Jacket Diamter – 0.9mm, Outer jacket colour – white , Outer Jacket Material – LSZH Shall be Front Patching Type, 1U high and rack mountable on standard 19” rack with mounting arrangements(B) 24F Loaded with Coupler, Pigtail and Splice Trays |
| 269 | SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m as per technical specification etc. as required. |
| 270 | Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories.(D) 15 U |
| 271 | Type 2 Switch: 24 Port POESupplying, installation, testing and commissioning of Layer 2 Manageable, Stackable Networking switch having 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, switch having a PoE power budget of minimum 370 Watts, minimum 4 SFP+ ports complete as per technical specification etc. as required. |
| 272 | Supply, Installation, Testing and Commissioning of 10G SFP+ LR singlemode transceivers, 1310nm, duplex LC termination supporting distance upto 10000 mtrs, inclusive of any hardware or interfaces such as modules for populating SM-LC transceivers complete as required. |
| 273 | Supply, Installation, Testing and Commissioning of Wireless indoor Access Point supporting Dual band with Wi-Fi 6 operation with MIMO support4 x 4, Minimum 3 streams, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port, as per technical specification etc. as required. |
| 274 | Providing and erecting IP Phone with display with all IP system supported as per technical specification etc. as required. |
| 275 | Sec.2.0 Video Survelance/CCTV SystemSupply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Camera, 1/2.8\" CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.8 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant, as per technical specification etc. as required. |
| 276 | Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Bullet Camera, 1/2.8\" CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.8 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant, as per technical specification etc. as required. |
| 277 | Supply, Installation, Testing & Commissioning ofIP Network TDN Low-Light IR PTZ Camera with auto tracking, 1/1.9\" CMOS, 2 MP @ 25fps, triple stream, Min. Illumination required 0.005 lux @ F1.6 (color) & 0.0005 lux @ F 1.6(B/W), 120dB True WDR, Min. Pixels 1920 × 1080, triple stream,6mm –180 mm 30x motorized focus & zoom lens, BLC, HLC, 3DNR, Defog, Electronic Image Stabilitzation, Privacy Mask, IR range with 150mtr IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 7 In/ 2 out,PoE, H.264 High Profile and MJPEG, PoE Class 5 and 12V DC/24VAC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 70° C. Certifications: ONVIF Profile S compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. as per technical specification etc. as required. |
| 278 | Sec.3.0 Fire Detection & Alarm & Digital EVAC SystemManual Fire Detection, Alarm and Control SystemSITC of 4 Zone Fire Alarm Control Panel, with 16X2 Character LCD Display, complies with UL - 864 and NFPA-72,Standards.Approval: UL-ListedOptional: 1) Provision to connect zone wise sounder (RE-25ZS) provided in a seperate cabinet. 2) Provision to connect zone wise relay (RE- 25ZC) provided in a seperate Cabinet 3) provision to connect repeater Panel through RS-485 with RE- RP Series.with SITC of Zone wise Relay contact box for 4 zones -RE-2554 fire alarm panelSITC of Zone wise Sounder contact box for 4 zones - RE-2554 fire alarm panel SITC of 5 Amps External Power Supply panel (Self Power) |
| 279 | SITC of Heat Combination (ROR and Fixed Temp) Detector with base.- Approval UL Listed. |
| 280 | SITC of Multi Sensor (Smoke and Heat combination) Detector with base - Approval: UL Listed. |
| 281 | SITC of Manual Pull Station - Dual Action Red in ColorApproval: UL Listed with Supply of Back box for Manual pull station. |
| 282 | SITC of Conventional Sounder cum strobewith 24V DC, Audiable Sound 75 db @ 1 mtr range (16 V DC). It is used for Fire, Burglar & Emergency Alarm System, Low current consume @ 47 -73 mA Candela: flashing every second, 4 candela settings:15/30/75/110cd output and 2 different tone audible sound. Make: Ravel - Approval: UL Listed. |
| 283 | Supplying and drawingof cable Fire Retardant PVC insulated copperconductorcableintheexistingsurface/recessed steelconduitoffollowingpairs,coresandsizeincluding connections and interconnections etc. as required.(A)Speaker cable Single pair, 2-core, 1.5 sqmm |
| 284 | Sec.5.0 Cable TV Distribution SystemProviding following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge.(4)TV Co-axial Socket outlet.Cat. III. |
| 285 | Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (b) RG – 6. |
| 286 | Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (e) RG – 11. |
| 287 | 5.0 FFTG WorksSupply, Installation, Testing and Commissioning of Electric driven Terrace Booster Pump suitable for automatic operation and consisting of following: complete in all respect as required.a) Horizontal, centrifugal, end suction back pull out pump at specified flow of 900 lpm at 40 m. head conforming to IS standards.b) Casing - CI, Imperller-Bronze, Shaft - SS 410, Mechanical sealc) Squirrel cage induction motor with suitable HP with synchronous speed 2965 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber belows, anti-vibration arrangement, cables & other accessories as required for complete Installation of pump set.e) Suitable cement concrete foundation with cementconcreteplaster complete with anti-vibration arrangement. |
| 288 | Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of fire fighting pumps consisting (Terrace Pump)(a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price.(b) Facility for more selections i.e auto or manual.(c) Protection failure and control cabling.(d) interlocking of pressure switch with pumps (if require)(e) Soft starter(f) Outdoor type IP 54(g) BMS compatible |
| 289 | Supply, Installation, Testing and Commissioning of 150 mm dia. Pressure Gauge (for all pipes) of range 0 - 15 Kg / cm² Polished Stainless Steel Case with positive seal against weather, moisture & dust, with Glycerine filled, screwed, nipple, isolation valve, U-type stainless steel siphon tube and complete with necessary as required. |
| 290 | Supply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be SPDT type suitable forsingle phase supply with diaphragm, IP 67 protection as required. |
| 291 | M.S. Above Ground PipeSupply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, Above ground M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required.All fittings up to 50mm shall be forged and above 50mm shall be butt welded.a) 100 mm dia. |
| 292 | b) 80 mm dia. |
| 293 | M.S. Under Ground PipeSupply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, Under ground M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / wrapping coating 4mm thick / 150mm widthas per IS:10221 etc., and two coats of anticorrosive primer and testing after Installation etc. as per specifications complete as required.All fittings up to 50mm shall be forged and above 50mm shall be butt welded.a) 100 mm dia. |
| 294 | Supply, Installation, Testing and Commissioning of C.I. Y type Strainer with S.S. Screen/SS 304 having 1.2mm perforation with require accessories.a) 100 mm Dia. |
| 295 | Supply, installation, testing and commissioning of C.I. Butterfly valve (IS:13095 , PN 16) with flanges, nut bolts, gaskets complete as required.a) 100 mm dia. |
| 296 | Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 1.6)a) 100 mm dia. |
| 297 | Supply, Installation, Testing and Commissioning S.S. Fire Hydrant Single Landing Valve with 80 mm N.B.flangedinlet, SS spindle controlled 63 mm dia femaleinstantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290.Includingfixing with anchor fastener and flanged tappingcomplete as required. |
| 298 | Supply, Installation, Testing and Commissioning of Fire Hose Cabinet wall mounting type 18swg (750 mm x 600 mm x 250 mm deep) with required accessories as per specification. |
| 299 | Supply, installation, testing and commissioning non-percolating rubber reinforced lined Fire Hose pipe (as per IS : 636) of 63 mm dia and 1no.x15 mtrs long. The hose shall be rated for burst pressure of 38 kg/sqcm. Hose shall be complete with ISI marked SSmale & femalecoupling (IS:903) bound as per specification. |
| 300 | Supply, Installation, Testing and commissioning of 63 mm dia instantaneous pattern SS short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required by the Local Fire Authority. |
| 301 | Supply, installation, testing and commissioning of First Aid Hose Reel (25 kg/cm²) conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, hose reel tubing type-3 as per IS: 444 of 25 mm dia x 30 mtr. long, painting, fixed wall type with fixing bracket, anchor fastener, bolts & nuts etc. complete as required by Local Fire Authority. |
| 302 | Supply, installation, testing and commissioning of forged brassBall Valve.(PN 25)a) 25mm dia |
| 303 | Supply, installation, testing and commissioning of Cast Iron Two Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required. |
| 304 | Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with necessary fittings. Size: 25 mm (For Riser) |
| 305 | Supply, installation, testing and commissioning of Pump on/off Remote switches to each internal hydrant valve with required accessories. |
| 306 | Supply, installation, testing and commissioning of XLPE insulated FRLS copper armoured Cable from each Pump on/off switches to Panel with all necessary accessories. Size: 4 core x 2.5 sq. mm |
| 307 | FFTG 02.00 Fire Extinguisher and Exit SignagesSupply, installation, testing and commissioning ofCarbon Dioxide (Co2) type Fire Extinguisher of 4.5 kg confirm to IS:15683, stored pressure, squeeze type with ISI marked fitted with required accessories including wall suspension brackets. |
| 308 | Supply, installation, testing and commissioning of ABC (MAP 90%)type6 kg stored pressure, squeeze type confirm to IS:15683, with ISI marked fitted with required accessories including wall suspension brackets. |
| 309 | Supply and fixing of ISI mark (IS:15683) Clean Agent HCF236fa, 10 Kg modular type ceiling mounted Fire extinguisher , Stored pressure type with pressure guage. |
| 310 | Providing, fixing AUTO GLOW photo luminescent Signage\"s as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes:a) Fire lift: size: 100 X 300mm |
| 311 | b) In case of Fire, do not use lift, use staircase: 200 X 200mm |
| 312 | c) Fire Equipment : size: 100 X 300mm |
| 313 | Getting Approval/NOC of Fire protection system (Hydrant, Sprinkler etc..) from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority. |
| 314 | KITCHEN FOR STUDENT HOSTEL Store Area - SS 4 Shelf Storage rack Size - 1100x550x1650 |
| 315 | Store Area - Wall mounted storage rack Size - 1500x300x250 |
| 316 | Store Area - SS Storage bins on wheels, caps- 100 kg |
| 317 | Store Area - Potato bin - 600x600x1200 |
| 318 | Wet Grinder AREA - Potato peeler - caps-10 kg |
| 319 | Wet Grinder AREA - Tilting type Masala Grinder caps-10 Ltrs. |
| 320 | Wet Grinder AREA - Pulveriser - caps-2 hp |
| 321 | Wet Grinder AREA - Dough Kneader caps-10 kg |
| 322 | Wet Grinder AREA - Four door refrigerator - caps-1000 ltrs |
| 323 | Wet Grinder AREA - Two Door Vertical freezer - caps-1000 ltrs |
| 324 | Veg cutting chopping Area - Work table with sink splash back & u/s, Size - 1500x600x850+150 |
| 325 | Veg cutting chopping Area - Work table with u/s and splash back, Size - 1500x600x850+150 |
| 326 | Veg cutting chopping Area - Veg cutting chopping m/c - caps- 110kg/hr |
| 327 | Cooking Area - Side table with u/s, Size - 600x600x850 |
| 328 | Cooking Area - Kadhai Fryer, Size - 600x600x850 |
| 329 | Cooking Area - Chapatti plate puffer, Size - 1200x600x850 |
| 330 | Cooking Area - Marble top chapati rolling table with u/s, Size - 1800x600x850 |
| 331 | Cooking Area - Two burner Indian cooking range with u/s, Size - 1350x600x850 |
| 332 | Cooking Area - Single burner Indian cooking range with u/s, Size - 600x600x850 |
| 333 | Cooking Area - Tilting type bratt pan, caps- 100 ltrs |
| 334 | Cooking Area - Tilting type boiling pan, caps- 100 ltrs |
| 335 | Cooking Area - Side table with u/s, Size - 600x600x850 |
| 336 | Cooking Area - Idlii steamer, caps- 180 idlii |
| 337 | Cooking Area - Pick-up table with u/s, 1500x750x850 |
| 338 | Service AREA - Thali Counter with 1 ambient 1/1 GN Pan and service rail &U/s (Three side covering) - Size - 1100x650+300x850 |
| 339 | Service AREA - BAIN Marie with 4 nos hot 1/1 GN pans and 1 No ambient GN Pans with service rail and u/s (Three side covering) Size - 1800x650+300x850 |
| 340 | Service AREA - Ice cream freezer, make- cellfrost |
| 341 | Service AREA - Visi Cooler, make- cellfrost |
| 342 | Service AREA - SS 4 shelf perforated glass & jug rack, size - 1100x550x1650 |
| 343 | Service AREA - Water cooler, caps- 100 ltrs |
| 344 | Pot wash & Dish wash area - SS Pot rack, size - 1100x600x1650 |
| 345 | Pot wash & Dish wash area - Pot wash sink unit, size - 900x900x850+150 |
| 346 | Pot wash & Dish wash area - Soiled dish table having 75mm deep top with garbage chute, size - 1200x750x850 |
| 347 | Pot wash & Dish wash area - Two sink pre wash unit with pre rinse shower, size - 1650x750x900 |
| 348 | Pot wash & Dish wash area - Hood type dishwasher machine, caps- 80 raack/Hr |
| 349 | Pot wash & Dish wash area - Clean dish landing table, Size - 1200x750x900 |
| 350 | Pot wash & Dish wash area - SS 4 shelf perforated clean dish rack, size - 1100x550x1650 |
| 351 | Kitchen Drain box - SS angle with perforated bascket & pipe grating, size - 1200x300x100 |
| 352 | Kitchen Drain box - SS angle with perforated bascket & pipe grating, size - 600x750x100 |
| 353 | Exhaust hood with baffle filter & fresh air & LED Lights, size - 1950x1100x500 |
| 354 | Exhaust hood with baffle filter & fresh air & LED Lights, size - 1600x1100x500 |
| 355 | Exhaust hood with baffle filter & fresh air & LED Lights, Size -1300x1100x500 |
| 356 | Exhaust hood with baffle filter & fresh air & LED Lights, size - 2400x1100x500 |
| 357 | Exhaust hood with baffle filter, size - 600x750x500 |
| 358 | GI duct for exhaust system, 800 r.sq.ft |
| 359 | exhaust blower, cap: 10000cfm |
| 360 | fresh air ducting, 600 r.sq.ft |
| 361 | fresh air intake blower with filter box having 15micron filter, cap: 6000 cfm |
| 362 | Gas Line from 1/2\" C-Class pipe with pressure regulator and other fittimgs like burner pigtails, N.C Valve with 3/3 Gas bank |
| 363 | Supply, Installation, Testing & Commissioning of MANI FOLD - 5X2 |
| 364 | Supply, Installation, Testing & Commissioning of MS BRAKET WITH STAND |
| 365 | Supply, Installation, Testing & Commissioning of MF BALL VALVE |
| 366 | Supply, Installation, Testing & Commissioning of N.R.V |
| 367 | Supply, Installation, Testing & Commissioning of C.P.T. - 2FEET |
| 368 | Supply, Installation, Testing & Commissioning of ADEPTOR |
| 369 | Supply, Installation, Testing & Commissioning of PRE-SET REGULATOR |
| 370 | Supply, Installation, Testing & Commissioning of D.B.C |
| 371 | Supply, Installation, Testing & Commissioning of MAIN LINE BALL VALVE |
| 372 | Supply, Installation, Testing & Commissioning of BRASS UNION |
| 373 | Supply, Installation, Testing & Commissioning of 1/2 X 3/8 N.C.V |
| 374 | Supply, Installation, Testing & Commissioning of B.P.T 4FT |
| 375 | Supply, Installation, Testing & Commissioning of MS BRACKET |
| 376 | Supply, Installation, Testing & Commissioning of 1/2 MS C CLASS PIPE |
| 377 | Supply, Installation, Testing & Commissioning of FRESH AIR HANDLING UNIT - 3HP WET SCRUBBER FOUNTAIN WATER SUPPLY WITHTANK DOUBLE SKIN BODY WITH PUFF INSULATION V TYPE BELT DRIVE WITH FORWARD CURVE FAN. ~ 1 YEAR WARRANTY ON MOTOR |
| 378 | Supply, Installation, Testing & Commissioning ofCENTRIFUGAL EXHAUST BLOWER WITH PUFF INSULATION KRUGER MAKE FAN WITH HIGH EFFICENT MOTOR KRUGER MAKE FAN WITH HIGH EFFICENT MOTOR1 YEAR WARRANTY ON MOTOR |
| 379 | ELEVATOR FOR BUILDING G + 9 (STUDENT HOSTEL/ 2BHK/ 1BHK/ APPARTMENT)Supplying, Erecting, Testing & Commissioning the passenger / stretcher lift having following main features:08 / 10 passengers . G + 9 floor with Rated Speed of 1.5 / 1.75 m/sec withmicro proce/PLC control and ACVVVF. drive, Duplex Control, Machine Room Less (MRL) - PREMIUM CATEGEROYMake : OTIS, Mitshubishi & Schindler Only (Joint Venture will not be allowed)[1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift duty 3 phase 440 V A. C. Permanent magnetic synchronous motor of proper rating with high efficiency shall be used.[2] Micro processor based / PLC, ACVVF, vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and safety controls.[3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car flooring shall be of anti skid PVC with choice of colour of engineer in charge. Car doors shall be of stainless steel grade 304, hairline finish with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 finished with emergency stop device, mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all floor switches must be with brail language as per lift act. S.S. Hand rail at 900 mm height for all three side. Door must be clear 900 mm centre openable.[4] All landing doors shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade of 304 with key holes and infrared curtains with Unlocking facility from outside.[5] Appropriate battery operated emergency light in the car along with alarm switch shall be provided.[6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be provided inside the car and at all floors.[7] Full height infra red curtain with multiple criss / crossing light beams shall be provided.[8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity.[9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept open till excess load is removed.[10] Spring buffers/PU Buffers shall be provided.[11] Car fan with automatic sleep timer shall be provided.[12] Voice annunciater with suitable music shall be provided in lift car.[13] Self diagnostics system for operational and safety parameters shall be provided in control panel.[14] Mechanical over speed governor, door key holes in the floor doors, fireman switch shall be provided.[15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machine etc…[16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as / if directed by engineer in charge. [17] Permanent wiring in lift machine room and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points shall be provided by the agency. Power supply of 3 phase 440 V shall be made available by department in lift machine room. [18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to erection of lift shall be made by lift agency without any extra cost.(granite/marble fixing around all landing door openings are notin lift agency’s scope.) [19] Agency has to provide all working drawings and documents and liaison services for obtaining all necessary permission from lift inspector and other authorities. [20] As per statutory requirement of Got. Of Gujarat lift & escalator act 2000, lift agency has to provide 1. Car top safety barricade 2. Push & talk communication system. 3. Fireman\"s switch operation at Ground Floor |
| 380 | INR Zero Only |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail