Tender For Construction Of Permanent Building To Government Arts And Science College At Thirukkattupalli In Thanjavur District., Thanjavur-Tamil Nadu

Department of Higher Education has published Tender For Construction Of Permanent Building To Government Arts And Science College At Thirukkattupalli In Thanjavur District.. Submission Date for this Tender is 23-04-2024. Building Work Tenders in Thanjavur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42923924
Corrigendum : Tender For Construction Of Permanent Building To Government Arts And Science College At Thirukkattupalli In Thanjavur District.
Open Tender
Indian
Tamil Nadu
Thanjavur
23-04-2024

Tender Details

Construction Of Permanent Building To Government Arts And Science College At Thirukkattupalli In Thanjavur District.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Apr-2024 Date Extension Date 23-04-2024

Key Value

Document Fees
Refer document
EMD
INR 761000.0 /-
Tender Value
INR 15 Crore /-

BOQ Items

Name of Work: Construction of Permanent Building to GovernmentArts and Science College at Thirukkattupalli in Thanjavur District.
Sl. No. Item Description
1Earthworkexcavationfor foundation in all soils and sub soils to full depth as may be directed except in hard rock requiring blasting inclusive of shoring shuttering, baling out water wherever necessary, refilling the foundation with excavated earth and depositing the surplus earth within compound in places shown by the departmental officers with an initial lead of 10 metre and initial lift of2 metre and clearing and leveling the site etc., complete complying with standard specification and as directed by the departmental officers.
2Earthwork Openexcavationin all soils and sub soils to full depth as may be directed except in hard rock requiring blasting inclusive of shoring shuttering, baling out water wherever necessary refilling the foundation with excavated earth other than sandy soil in layers of not more than 15 cm thick layers well rammed and depositing the surplus earth within compound in places shown by the departmental officers with an initial lead of 10 metre and initial lift of2 metre and clearing and leveling the site etc., complete complying with standard specification and as directed by the departmental officers.
3Supplying and Filling in foundation and basement with m sand gravel mix 1: 1 in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
4Supplying and Filling in foundation and basement with filling m sand in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
5Refilling basementwith excavated earth other than sand with an initial head lead of 100 mts. and depositing the earth as shonw by the departmental officers in layers of not more than 15cm thick well rammed, watered and consolidated etc. complete complying with standard specificationand as directed by the departmental officers..
6Supplying and filling in foundation and basement with Gravel in layers of not more than 15cm thick well rammed watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
7Supplying and filling of 40mm ISS metal in dispersion trench around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc. complete. (The rate including cost of metal filling etc. complete complying with standard specification.
8Supplying and filling of 20mm ISS metal in dispersion trench around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc. complete. (The rate including cost of metal filling etc. complete complying with standard specification.
9Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam specification including premixing the materials using 0.396cum of 45-22.40mm, 0.528cum of 22.4-2.36mm ,0.396 cum of 2.36mm and below with water at OMC in mechanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in SubBase /Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete
10Cement concrete 1:5:10 (one cement, five M sand and ten aggregate) using 40mm gauge hard broken blue granite stone jelly for foundation and basementincluding dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification and as directed by the departmental officers.
11Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) For column footing plinth beam etc.
12Supplying and erecting steel centering including necessary supports for plain surfaces, for all RCC works including strutting upto 3.29min all floors using mild steel shutters of size 90cmx60cm of BG 10 stiffened with mild steel angles of size 25mmx 25mmx3mm laid over silver oak (Country wood) Joists of size 10cmx6.5cm spaced at about 90cm c/c and supported by casurina props of 10cm to 13cm dia. (spaced at 75cm c/c) etc., complete complying with standard specification and as directed by the departmental officers.(The centering will be removed after specified period of concrete without damaging the concrete)
13For planesurface such as RCC floor slab, roof slab, beam litels bed blocks, landing slab, waist slabs and beams, etc.,
14For plane surfaces such as RCC square or rectangular column, top and bottom slab of sunshade, boxing sill etc. complete as directed
15For plane surface such as Vertical surfaces such as sunshade, boxing vertical drops, facia for sunshade and other vertical walls etc.,
16For Curved surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall etc
17Providing additional strutting using casurina poles to centering of RCC slabs or plane surfaces for every addtional 1 metre height or part there of but not less than30cm over the initial height of 3m from floor level using casurina props of 10cm to 13cm dia including cross bracings etc., complete complying with standard specification and as directed by the departmental officer.
18Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance usingwith IS:456-2000, 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of m sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
19For foundation and basement
20In Superstructure in Ground floor
21In Superstructure in first floor
22In Superstructure in secondfloor
23In Superstructure inthirdfloor
24Supplying, fabricating and placing inposition of steel reinforcement using MS/Ribbed tor steel rods for all RCC works as per the design given including cost of steel and G.Ibinding wire also in all floors etc., complete complying with standard specification and as directed by the departmental officers.. ( The contractor will have to make his own arrangement for the supply of M.S plain rod/ RTS rod and black binding wire )
25Brick work in cement mortar 1:5 (one cement and five M sand) using CountryBricks of size 8-3/4" x 4-1/4" X2-3/4 including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
26For foundation and basement
27For superstructurein ground floor
28For superstructurein firstfloor
29Brick work in cement mortar 1:6 (one cement and six M sand) using CountryBricks of size 8-3/4" x 4-1/4" X2-3/4" including curing etc., complete complying with standard specification and as directed by the department officers. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
30For foundation and basement
31For superstructurein ground floor
32For superstructurein first floor
33For superstructurein second floor
34For superstructurein third floor
35Damp proof Course with Cement Mortar 1:4 (One cement & four sand) 12mm thick mixed with water proofing compound of approved quality confirming to ISS @ 2% by weight of cement used etc complete complying with standard specification and as directed by the departmental officers.
36Brickpartion wall 10.80cm thickin cement mortar 1:3 (one cement and threeM sand) using CountryBricks of size 8-3/4" x 4-1/4" X2-3/4 including fixing hoop iron reinforcement if found necessary, laying, finishing and curingetc., complete complying with standard specification and as directed by the departmental officers.
37For superstructurein ground floor
38For superstructurein firstfloor
39For superstructurein second floor
40Supplying and Fixing New Cuddappah slab fine polished of approved quality of38 / 40mm thick including cost of cuddappah slab for cupboards,transportation to work site, labour charge for forming grooves in masonry if necessary and laying the slab in position with cement mortar 1:3 (One cement and three m-sand) etc., completecomplying with standard specification and as directed by the departmental officers.
41Supplying and Fixing RCC precast slabin reinforced cement concerete 1:2:4 (One ofcement, two of sand and four of aggregate) using 20mmhard broken stone jelly and river sand, excluding the cost of reinforcement grills and including fabrication charges, moulding, curing, finishing charges and fixing in position neatly etc., complete complying with standard specification and as directed by the departmental officers.
4250mm thick
43Supplying and fixing of special type Terra Cotta Jally of size 20x20x5cm of approved pattern including pointing neat finishing and labour charges for fixing the jally in position etc., complete complying with standard specification and as directed by the departmental officer.
44Fabricating supplying and fixing in position CRCA pressed steel box section 18 gauge or 1.25mm thick for door frames of section size 105mmx60mmx1.25mm thick with necessary rebate of size 35x15mm for housing door shutters conforming to IS specification.Frames shall be fabricatedto the specified door size with joints properly welded and grinded. Stiffeners with 25x3mm MS flat shall be provided around the frame at 60cm intervals. The cost shall also include for providing 3 Nos. of MS clamps with 25x3 flats each on either sides of door frame, providing bottom tie, with 10mm dia MS rod,providing necessary holes for receiving tower bolts 2 Nos. with stiffeners on inner side, providingthe required number of I.Ohinges of size 125x30mm for shutters properly welded to the frames, finishing the door with one coat of good quality red oxide primer with cement concrete 1:2:4 (One cement, two sand and four aggregate) using 20mm gauge hard broken granite stone jelly packed inside to the frame including cost of all materials, fabrication and conveyance to the site and fixing in position with necessary scaffolding etc., complete complying with standard specification and as directed by the departmental officer.
45Supplying and fixing in postion of 35mm thick solid core flush door shutters single leaf with following specification. with Commercial ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No.250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No.200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, complete complying with standard specification and as directed by the departmental officers.
46Supplying and fixing in postion of 35mm thick solid core flush door shutters Double Leaves with following specification. with Commercial ply on both sides and with TW lipping of size 35x12mm on all edges with necessary adhesives and C.P. Screws Alu. Butt Hinges (6 nos. 250 x 16 mm Size) Alu. Aldrop1 No.250 x 16 mm Size, Alu. Tower Bolt 2 No. 250 x12 mm size, alu. Tower Bolt 2 No.200 x 12 mm size, D type alu. Handle 200mm length 2 No., alu. door stopper with rubber bush 2 No. shall be provided, complete complying with standard specification and as directed by the departmental officers.
47Supply and Fixing of M.S. steel doors with Single Leaves following specification. MS angles of size 40x40x 6mm at 3.5 kg/m used for the outer frame and MS angles of size 35x35x5mm at 2.60 kg/m for the shutter frames. Stiffners with 32x6mm at 1.50 Kg/m. MS flat is provided as the lock rail of the door and welded infact of both ends to the shutter frame, 18 gauge CR sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50 Kg / RM and MS flaton the rear side of the door sandwitching the CR sheet for rigidity with locking rail and bottom tie arrangements. Additional stiffners with 18x5 mm at 0.7 kg/m MS flats are provided horizontally diagonally on the rear side of the shutter. 2Nos of hinges in case of single leaf and 4Nos of hinges in case double leaf shutter is provided 6 Nos of hold fasts 200 length 40x40x6mm M.S. angle spliced at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. one at top and the other atbottom are provided. One aldrop is provided incase of double leaves door at lock rail section in the door. For single leaf doors, one more aldrop is provided in the inner side at the lock rail section of the door.
48One rotating locking arrangements at the inner side of the door and additional provision for locking arrangements for lock is provided with 32x6mm MS flat on the rear side of the door at an appropriate place incase of a double leaves door MS flat 32x6mm at 1.50 kg/m is provided on the edge of one shutter to conceal the gap between the shutters. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given a shop coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials labour charges transportation taxes and all other incidental charges etc.,complete complying with standard specification and as directed by the departmental officers..
49Supplying and fixing 30mm thick solid core PVC door shutter withPVC frame of size 50x45mm with suitable rebate for housing the shutter consisting of frame made out ofMS tubes 19 gauge thickness and size of 19x19mm for styles and 15x15mm for top and bottom rails, MS frame shall be covered ith 5mm thick heat moulded PVC "C" channel of size 30x50mm forming styles and 75x50mm for top rai8l, lock rail and bottom rail on either side and 10mm thick 20mm wide cross PVC sheet as gap insert for tap rail, botytom rail, panelling of 5mm thick PVC sheet bearing on either side and join together other side etc. An additional 5mm thick PVC strip of 20mm width is to be stack and the interior side of the "C" channel using PVC sealant adhesiv e including cost of allfurniture fittings, such as aluminium aldrop of size 250x16mm -1 No. aluminium tower bolt 250x12mm-1 No. aluminium D type handled 200mm etc. complete complying with standard specification and as directed by the departmental officers.
50Supplying and fixing in position of solid panel PVC door with sliding aluminium frame. The outer frame will be 62x38x2mm @ 1.17 kg/m and 40x20x2mm Aluminium "C" section. Soild PVC door shutter using 16 Gauge 19mm MS Sq. tubes for styles and outer frames. 15mm Ms. Sq. Tubes for top Lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for paneling shall rigidly fixed in position including necessary furniture fittings. The overall size of styles shall be 50mmx30mm. The overall size of top rail, lock rail and bottom rail shall be 75mmx30mm, with suitable rebate for housing the shutter etc., complete complying with standard specification and as directed by the departmental officer.
51Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
52Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
53Manufacturing, Supplying and Fixing in position of M.S.steel window with following specifications. The outer frame of window made out "Z" section (F7D) of size 33x25x3mm at 1.419 Kg/m and mullion of "J" section (F4B) of size 45x25x3mm at 2.28 Kg/m. Shutter made out of (F7D) section of size 33x22x3mm at 1.419 Kg/m. Each openable shutter should not be exceeded a width 600mm to enable separate operations and easy maintenance. 2Nos. of sturdy hinges and one number of handle cum latch of special type make with 18x5 MS flat are revetted to the shutters of an appropriate height ineach window shutter. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. Each shutter having an adjustable window stay made out of 18mmx5mm at 0.70 kg/m MS flat of length 320mm with free adjustable positions.
54A matching peg is provided in the outer frame of the window, at suitable place, 4Nos of holdfasts of 200mm lengthMS angle 40x40x6mm the ends are welded to the outer frame of the window, 18 mmx 5 mm at 0.70 kg/m MS flat is welded to the shutter attwo places, equal distance from each other from top and bottom of the shutter. 18 gauge cold rolled sheet of superior quality is laid as panel in the shutter frames and welded intact. Stiffeners with 18x5mmat 0.70 kg/m MS flat of suitable length welded diagonally to all four corners of each openable shutter to hold the CR sheet in position firmly. MS square bars of 12mm size is welded to the inner face of the window at equal intervals not exceeding 100mm edge to edge between them. All members are painted with one coat of anticorrosive red oxide primer as directed by the departmental officers. All sections used should confirm to IS 7542 / 1990. The rate includes cost of all materials, labour charges, transportation totaxes and other incidental charges etc. complete.
55Supplying and fixing MS grills to doors, windows and ventilators etc. using necessary MS flats (or)square rods for inner members and outer members which should be fixed to window frames as directed and design given by the departmental officers inclusive of cost of providing one coat of best quality red oxide primer etc., complete complying with standard specification and as directed by the departmental officers .
56Manufacturing, Supplyingand fixing Stainless Steel hand rail for staircase using 50mm dia 304L Gradestainless steel pipe of 1.60mm thick at at required locations to a height of 1000mm from finished floor level welded to 38.30 mm dia stainless steel pipe post of 1.00mm thick as vertical at 900 center with 3nos of 25.40mm dia intermediatehorizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100x100x6mm MS base plate encased in the base concrete. The rate is inclusive of charges for cutting , bending , welding , grinding polishing conveyance, electrical charges , etc., completecomplying with standard specification and as directed by the departmental officers.
57Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for toilets of Differentially abled person using 50.80mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing.The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade.The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete complying with standard specification and as directed by the departmental officers.
58Plain Cement concrete 1:2:4 (One cement two m-sand and fouraggregate) using machine crushed 20mm gauge hard broken granite stone jelly excluding cenetering, shuttering and, but including laying, curing and finishing etc., complete complying with standard specification and as directed by the departmental officers.
59Finishing the top roofwith one course ofsolar reflecting ceramic tilesof size 305x305x7mm thick of approved quality set in cement mortar 1:3 (One cement and three sand) (12mm thick ) and mixed withfor 10M2 / 4.00 kgEpoxy Packing conforming to ISS including curing etc.,complete complying with standard specification and as directed by the Departmental officers.
60Brick Jelly Lime Concrete of 1:2:5 (One Lime,Two mSand and Five Brick jelly ) with 40 mm hand broken brick jelly for Sunken portionsincluding dewatering wherever necessary and laid in layers of not more than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification.
61Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three P-sand) 10mm thick with Bonding agent Cebex112, Zydex- Zycrete 2X or other Equalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workablity and air entrainment including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
62Stucco plastering 12mm thick using blue granite chips of size 10mmover the existing base plastering with cement mortar 1:5, 12mm thick, etc., complete complying with standard specifications and as directed by departmental officers.
63Plastering with cement mortar 1:5 (one cement and five P-sand) 12mm thick mixed with Bonding agent Cebex112, Zydex- Zycrete 2X or other Equalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workablity and air entrainment used finishing in all floors using fine P sand including neat finishing, curing,etc., complete complying with standard specificationand as directed by the department officers.
64Plastering with cement mortar 1:3 (one cement and three P sand) 12mm thick with WPC 2% by weight of cement with Bonding agent Cebex112, Zydex- Zycrete 2X or other Equalent compound conforming to BIS at 200 ml of one cement bag (50kg) for increased workablity and air entrainment used in all floors using fine Psand including neat finishing, curing,etc., complete complying with standard specificationand as directed by the department officers.
65Supplying and fixing in position best approved of ISI qualityof following dia PVC rain water down fall pipes having a working pressure of 4 kg / sq.cm including cost of necessary PVC shoe, PVC bend, C.I. gratings of required dia. and special clamps, brass screws, nails etc., and fixing of cast iron gratings at juction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cost of removable iron grating. The PVC pipe shall be fixed on wall with special type of clamps. Special type "U" clamp at the centre of the pipe line shall be fixed in addition to those for more than 3.0M pipe length complying with standard specification and as directed by the departmental officers..
66160mm dia of PVC rain water down fall pipes.
67110mm dia of PVC rain water down fall pipes.
68Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
69Paving the floor with pre polished concrete Hydraulically pressedAnti skid tiles (like Eurocon Tiles) 20mm thickin all floorsset in cement mortar 1:3 (One cement and three sand), 20mm thick and pointing with the cement including adding suitable colouring pigments of match with colour of tiles and finishing and curing as directed by the departmental officers including cost of tiles, and all other materials, transportation charges and labour charges for laying of tiles as directed by the departmental officers complete complying with standard specification. (The tiles should be got approved by the departmental officers before use on work.)
70Paving the floor with Stain free nano polished vitrified tiles(like Marbonite or equivalent)of approvedquality and colour of size 600 x 600x 8 mm thicknessin all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification and as directed by the Departmental officers. (The tiles should be got approved by the Departmental officers before use on works).
71Paving the floor with best approved quality fine polished Jet Black Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
72Paving the floor withTactile paver type of new tack BT yellow colourceramictilesof approved quality and colour of size 305 x 305 x 15mmin all floors over a base layer of cement mortar 1:3 (one cement and three M sand) 20mm thick and pointing with white cement using 0.30kg/m2including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification andas directed by the departmental officers . (The tiles should be got approved by the departmental officers before use on works).
73Paving the floor with best approved quality fine polished Flamed Steel Grey Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
74Labour charges for finishing the top of working tables and staircase step portion with nosing arrangements in Granite slab tiles including cutting the edges and polishing including cost of polishing materials complete complying with standard specification and as directed by the departmental officers.
75Labour charges for Grooving the Granite slab for staircase step portion including cutting the edges and polishing including cost of polishing materials complete complying with standard specification and as directed by the departmental officers.
76Finishing the top of flooring with granolithic floor finish of following thickness with plain cement concrete of mix 1:2:4 (One cement, two M sand and four aggregate) using 20mm / 10 to 12mm ISS gauge hard broken granite stone including finishing the top smooth and forming thread lining and curing etc., complete complying with standard specification and as directed by the Departmental officers.
7725mm thick
78Paving the floor withcolour designceramictilesof approved quality and colour of size 305 x 305 x 6mmin all floors over a base layer of cement mortar 1:3 (one cement and three m sand) 20mm thick and pointing with white cement using 0.30kg/m2including adding suitable colour pigments to suit the colour of tiles finishing perfectly and curing etc., including cost of tiles, all materials and incidential charges, transportation charges and labour charges for laying tiles etc., complete complying with standard specification andas directed by the departmental officers . (The tiles should be got approved by the departmental officers before use on works).
79Dadooing the walls withcolour design glazedtiles of size 300mmx 450mmx 8mm of approved quality in all floors set in cement mortar 1:2 mix (one cement & two M-sand)10mm thick and pointing with white cement using 0.4 kg/m2 including adding suitablee colour pigments to suit the colour of tiles including finishing the joints neatlyand curing etc.,complete complying with standard specifications. (The tiles should be got approved by departmental officers before use on the work).
80White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directedby the departmental officers..
81Painting the walls two coats with best Oil bound distemperof approved quality (to be approved by the Executive Engineer before use on works) over one coat of primer for newly plastered wall including preparation of surface and finishing neatly including cost of all materials, brushes, scaffolding charges etc., complete complying with standard specification and as directed by the departmental officers.
82Painting the exterior walls surface two coats of best and approved first quality and colour of Exterior emulsion paintin all floors over one coat of primer including preparation of surface, wall puttytwo coats with good quality including cost ofwall putty , emmary sheet, plates, etc. and including labour charges for rubbing the wall scrapping putty pasting works and makinggood smooth surface and finishing neatly etc.,. complying with standard specification and as directed by thedepartmental officers etc. complete. ( The make, quality and colour of paint should be got approved by the departmental officer before use of work)
83Paintingthe new wood work two coats withbest approved first quality and colour of synthetic enamel paint over a priming coat of approved quality in all floors including cost of paint, labour and other materials like brushes, putty andscaffolding charges etc., complete complying with standard specification and as directed by the departmental officers. (The make quality and colour of paint should be got approved by the departmental officer before use on work).
84Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc.,complete complying with standard specification and as directed by the departmental officer. (Thequality and colour of paint should be got approved by the departmental officer before use on work).
85Providing expansion joint of 20mm width in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non - absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directedby the departmental officers..
86Providing expansion joint of RCC floor slab for 20mm width using polysulphide as sealent ontop and bottom for a depth of 7.5mm each and packing the inner space using compressible non - absorbent, filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directedby the departmental officers..
87Providing expansion joint of 20mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and includingfilling the inner space with suitable non - absorbent, flexible and well compressible filler materials of approved quality and covering top surface with GI sheet 30cmwide and 1.6mm thick using phill plugs, GI screws, limpetcup washers, bitumen washers, etc., complete complying with standard specifications and as directedby the departmental officers..
88Providing Anti – termite treatment to soil adjacent and under buildingfoundation, plinth periphery of the building by application of chemicals of IS 6313 part I to IV in stage to suit the progress of work consist as per the detailed specification as below (Measurements taken for the plinth area for the purpose of payment) including braking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport & storing etc., complete and as directed by the departmental officers.(The chemical should be got approved by Executive Engineer before use on work). Stage -1 : Spraying Anti –termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation. Stage-2 : Spraying Anti –termite chemical solution to the grade beam level, spraying has to done for to grade beam brick masonry contact with the back fill earth. Stage-3 : Spraying Anti –termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out and sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring throughout. Stage -4 : Spraying Anti –termite chemical solution alround building outside by making holes with crow bar before laying plinth protection and the holes to be close after the treatment.
89Supplying and installation of Ceramic Steel chalk writing board with the following specification.The 2mm GI Sheet is placed with wall side over the GI sheet necessary adhesive is spreaded and fixed the 9mm MDF board on the GI sheet 0.40mm thick ceramic steel chalk board is provided over the MDF board and the whole arrangements are fixed to the frame using heavy anodized Aluminium section and Chromium plated provided in the corners.The whole arrangement are fixed to the wall using wooden plugs and screws etc., The rate includes all above materials, labour charges and taxes etc., complete complying with standard specification and as directed by the departmental officers.
90Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) powder type fire extinguisher of 6 kg capacity as per IS:15683with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc. including conveyance, all incidential charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc. complete as per standard specification and as directed by the Departmental Officers. Make: Excellent/Safety First/equivalent.
91Supply and fixing of carbon-di-oxide gas type 2 kg. capacity Fire extinguisher as per new IS:15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc. including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc. complete as per standard specification and as directed by the Departmental Officers. Make: Excellent/Safety First/equivalent.
92Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approved by the Dept. Officials.) Design the framing system (i.e. male & Female frame) to support vision panels,spandrel panels either with glass or aluminium composite panel, openable, window panels on a continuous framing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm. Glazing of panel shall be done only at factory at the controlled atmosphere etc., complete and complying with standard specification andas directed by the departmental officers
93Supplying and erecting in position of 250 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc.The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact
94Supplying and fixing ornamental Brass-in-lay Burma Teak Wood Entrance Door with a size of2.10m x 2.55m with six leaves as per the drawing and design as approved by the departmental officers. The clear opening of each door shall be of 2.00m. The outer frames are of finished size 175mm x 125mm.The Each door shall have two leavesof 1/3 paneled and 2/3 glazed. The Outer frame of the shutter of finished size of 150mm x 50mm.All the Panels shall be of finished 50mm thick. The main outer frame, shutter frame and panels shall be engraved with computer design ornamental carving works of approved pattern with skilled carpenter as directed by departmental officers. All the glazing works shall be done with design painting works. Necessary grill protection arrangements shall be made for the glass portion. The door frame and shutters shall given two coats of best and approved quality of high Glossy Polyurethane finish. The rate includes cost of best and approved quality of Burma Teak wood, design painted glass, Brass hinges, Tower bolts, Aldrop, locking arrangments, ornamental handles, brass screws and labour charges, transportation charges, all taxes, etc., complete andcomplying with standard specification andas directed by the departmental officers .
95Supplying and fixing of Incinerator for Ladies Toilet etc., complete complying with standard specification and as directed by the departmental officers.
96Providing cupboard shutter using termite/water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed insidethe shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc. as directed by the departmental officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer before use on work.
97Supplying and laying of 63 mm thick high strength type of interlocking rubber moulded hydraulic pressed paver block of approved colour made up of designed concrete mix 1:1:2 using 10 to 12mm size HBG stone jelly in required shapes and sizes having minimum compressive strength of 40 N/mm2 to be laid in flurrying bone pattern with approved non sticking surface at top. The rate is inclusive of levelling the site, compacting with power compactor and sweeping the sand grouting and also inclusive of transportation charges, loading, unloading and labour charges for laying the paver block, etc. complete complying with standard specification and as directed by the departmental officers.
98Supplying and Fixing of Aluminium Dye Cast Letters of followingsize and . The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process etc., complete complying as per standard specification and as directed by departmental officers.
99Aluminium Dye Cast Letters 9"" size
100Supplying and fixing in position Indian water closet oriya type of size 580x440mm white glazed earthernware of approved quality with "P" trap or "S" trap conforming to IS 2556-Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to PVC. pipes by dismantling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specification and as directed by the departmental officers.(The Oriya type Water Closet andall accessories should be got approved by the departmental officers before use on work)
101Supplying and fixing in position White Glazed European water closet of best quality and approved make with 100mm P or S trap with double flapped rigid PVC.seat cover with chromium plate brass hinges, including supplying and fixing PVC. Low level flushing tank 10 litre capacity of approved quality on wall with teak wood plugs, brass screws and 2 numbers 15mm dia gun metal wheel valve, 15mm dia nylon connection and giving necessary water supply connection as directed by the departmental officers. The rate includes cost of 100mm dia PVC.Pipe 60cm long including cost of 3 Kg.of white cement 6Kg.of cement, spunyarn, shellac, thread ball, teak wood plugs, brass screws 75mmx10mmetc., complete complying with standard specification and as directed by the departmental officers. (The European Water Closet and flushing tank should be got approved by the Departmental Officers before use on work.)
102Supplying and fixing in position PVC Nahini trap of size 110x75mm with best pvc gratings of approved brand and quality with fixed over a bed of brick jelly lime concrete 1:2:5(one part of lime,two parts of sand and five parts of 40mm size brick jelly)and finished with cement Mortar 1:3(one cement and three sand)including dismantling masonry works wherever found necessary and making good the damaged portions to the original condition giving connections to the pipe etc., complete complying with standard specification and as directed by the departmental officers. (The PVC Nahini trap with grating should be got approved by the departmental officer before use on works).
103Supplying and fixing in position best quality of approved make white glazed earthernware wash hand basin (without pedestal) of size 550x400mm with a pair of cast iron brackets , including cost of 15mm diametre brass chromium plated pillar tap, 32mm diametre C.P.waste, 32mm diametre PVC waste pipe with rubber plug and chain, 15mm diametre gun metal wheel valve, 15mm dia brass nipple, 15mm dia nylon connection etc. including fixing the wash hand basin in the wall in position with pair of C.I.brackets with teak wood plugs and screws and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anti-corrosive paint including testing for leakage etc., complete complying with standard specification and as directed by the departmental officers.(The wash hand basin and specials should be got approved by the departmental officers before use on work)
104Supplying and fixing in position of Indian make white glazed earthen ware lipped mouth flat back Urinal of best approved quality with 32mm dia bell mouthed PVC connection,15mm dia G.M wheel valve,fixing the Urinal to the wall in position with necessary T.W. plugs,clamps,screws shellac etc.,including dismantling masonry if necessary and redoing the same to original condition,fixing the 15mm GI pipe connection and wheel valve, painting the pipe with two coats and checked without any leakage etc., complete complying with standard specification and as directed by the departmental officers.(The urinal should be got approved by the departmental officers before use on work)
105Supplying and fixing in position of polished white marble slab (Adanga) of 20mm thickfor urinal partition of size 1.20x0.60m includingand fixing the marble slab with C.M.1:3 etc. complete complying with standard specification and as directed by the departmental officers.
106Supplying and Fixing ofwhite Porcelainsink of size 600mm X 450mm X 200mm including cost of 32mm dia "B" class GI waste water pipe with rubber, plug and chain and 32mm dia CP waste coupling, 15mm dia brass nipple including fixing the sink in position and testing for leakage etc., completecomplying with standard specification and as directed by the departmental officers.(The sink and specials should be got approved by the Executive Engineer before use on works). (For fixing the sink on masonry support walls to be measured and paid in main item.)
107Supplying and fixing PVC Ventilating shaft of 110mm dia (having working pressure 4 kg / sq.cm) and 3 m height including cost of cylindrical cowl of best approved quality etc., complete complying with standard specification and as directed by the departmental officers. The PVC ventilating shaft should be got approved by the departmental officers before use on work.
108Supplying and fixing in position 150mm dia stoneware tee of approved best quality and provding leak proof joints with cement, spun yarn, etc., including dismantling the brick work and re-doing the dismantled portion to the original condition, etc., complete complying with standard specifications (The stoneware tee shall be got approved by the Executive Engineer before use on work)
109Supplying, laying and jointing PVC soil / waste pipesof approved and best variety conforming to IS. Specification with ISI. mark of the following sizes including, cutting and threading of PVC Pipes, fixing specials but excluding cost of such specials but including fixing to wall with necessary teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in roof and making good the dismantled portion to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges. The PVC Pipes should be got approved by the Departmental Officers before use on work. Above ground level.
11075mm dia PVC soil pipe
111110mm dia PVC soil pipe
112160mm dia PVC soil pipe
113Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
114160mm dia PVC"Y"
115160mm dia PVC Plain Elbow
116160mm dia PVC door Elbow
117110mm dia PVC door "Y"
118110mm dia PVC Plain Elbow
119110mm dia PVC door Elbow
120PVC Cowl110mm dia
12175mm dia PVC door "Y"
12275mm dia PVC Plain Elbow
12375mm dia PVC Bend
124PVC Cowl75 mm dia
125160mm dia PVC Tee
126Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulationmethod using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the departmentalOfficers) including construction of mud pit.
127up to 60m depth below ground level
128Reaming 140/150 mm dia pilot bore to 300mm dia bore etc., complete complying as standard specification and as directed by the departmental Officer.
129up to 60m depth below ground level
130Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the departmental officer
131Supply of 160mm diaPVC special casing pipe without slot of best approved quality having pressure of 6 kg/sq.cm. etc., complete as directed by the departmental officers. The pipe should be got approvedby the Executive Engineer before use on works.
132Supply of 160mm diaPVC special casing pipe with slot of best approved quality having pressure of 6 kg/sq.cm. etc., complete as directed by the departmental officers. The pipe should be got approvedby the Executive Engineer before use on works.
133Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed bydepartmental Officers and conducting yield test by "V" notch method.
134Supply and fixing of160mm dia PVC End cap of best approved quality having pressure of 6 kg/sq.cm. etc. complete as directed by the departmental officers. The pipe should be got approvedby the departmental officer before use on works.
135Supplying and erecting 3 phase multi stage 3 H.P Submersible Pumpset suitable for 150mm dia Borewell with ISI IS 8034 with 3 phase Panel Board - Star Delta with two level guard and Auto start includingof approved make conforming to ISI.including cost of all accessories, transportation charges, labourcharges for erecting and fixing the motor in position testing as directed by the Departmental Officers complete complying with standard specification. The quality and standard of product should be got approved by the Departmental Officers before erecting. Necessary warranty card should be produced before erection of Motor.
136Supplying and fixing of 3 x 4 sq.mm PVC insulated and sheated 3 core flat type copper cable confirming to IS 694/1990etc. complete complying with standard specification as directed by the departmental officers.
137Supplying and fixing of MS borewell clamp suitable for 150mm dia pipe and 4 Nos. ofbolts and nuts of best approved quality etc. complete andcomplying with standard specification andas directed by the departmental officers .
138Supplying and tying of Nylon rope of 18mm dia thread make with best quality for holding submersible pump etc., complete as directed by the Executive Engineer. The Ropeshould be got approved by the Executive Engineer before use on works.
139Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) with necessary earth work anf refilling charges the earthwork and refilling charges shoul be paid seperatly, etc., complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works. For External Water supply arrangements. (Below Ground Level)
14050mm dia UPVC pipe
141Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs,UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works.For External Water supply arrangements. (Above Ground Level)
14250mm Dia UPVC Pipe
14332mm Dia UPVC Pipe
14425mm Dia UPVC Pipe
145Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs,UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The UPVC pipes shall be got approved by Executive Engineer before use on works.For Internal Water supply arrangements. (Above Ground Level)
14620mm Dia UPVC Pipe
147Supplying and fixing in position 15mm dia Chromium Plated brass screw down tap (heavy type) of approved make conforming to ISS.and including cost of shellac, thread complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Departmental Officers before use on the work)
148Supplying and fixing in position UPVC specials such as plain bend and shoe of various sizes of best approved quality conforming to ISS.and providing leak proof joints including fixing to wall and giving connection to the UPVC. Pipes including,dismantling the brick masonry/RCC.floor or roof slab and redoing the disturbed portion to original condition etc.complete complying with standard specification and as directed by the Deptmental Officers.
14950mm.dia UPVC Tee
15050mm.dia UPVC Union
15150mm.dia UPVC Hex Nipple
15250mm.dia UPVC Coupling
15350mm.dia UPVC Elbow
15440mm.dia UPVC Tee
15540mm.dia UPVC Union
15640mm.dia UPVC Hex Nipple
15740mm.dia UPVC Coupling
15840mm.dia UPVC Elbow
15932mm.dia UPVC Elbow
16032mm.dia UPVC Tee
16132mm.dia UPVC Union
16232mm.dia UPVC Hex Nipple
163Supplying and fixing in position best quality and approved variety of new Gun Metal Gate Valve / Wheel Valve heavy typeexcluding the fixing charges but including necessary cutting & threading of GI pipes for jointing the GI specials and providing two coats of painting with good quality and approved variety of anti-corrosive paint over a coat of red oxid primer coat in the case of pipe line above ground level and one coat of tarring in the case of pipe line below ground level etc., complete
16440mm dia Gun Metal wheel Valve
16532mm dia Gun Metal wheel Valve
166Supplying and fixing in position of Man hole cover with SFRC frames of size 600x600mmof best approved quality and as per Indian standard specificationmake etc., complete complying with standard specificationand as directed by the departmental officers. (The Man hole cover should be got approved by the departmental officers before use on work).
167Drilling of borewells of size 6" to 8" dia. in sedimentary formation using hand boreset including insertion of casing pipe etc., and supplying and packing of pebbles (Conveyance of hand bore set including loading and unloading to be done by the contractor)
168Supply of 110mm PVC special blue slotted casing pipe of best approved quality having pressure of 6 kg/sq.cm. etc. complete as directed by the departmental officers. The pipe should be got approvedby the Executive Engineer before use on works.
169Supplying and fixing300 mm diaRCC Hume pipe pressure nonspun pipe with socket and spigot end as per IS 458/2003 manufactured with sulphate resistance cement with 12 mm HI- alumina lining with rubber ring joint etc., complete complying as per standard specification and as directed by departmental officers.
170Providing mixing laying polymer based water proofing treatment for the sunken toilet by applying cement based fiexable WPC conforming to IS 2645 to a thickness of 1mm of the prepared surface of the roof slab / floorslab as per specification mendioned above providing cm 1:3 water proofing cover plaster to a thickness 12mm. The malaime coating with admixture of approved make rate quoted is inclusive of preparation of surface which including cleaning of surface polymer morter, curing, labour, tools equipments etc., rate inclusiveof cement and sand required for the treatment the coat and labour charges for fixing 25mm dia pressure pipe 15 kg / m2 to length of 45 cm for drip pipe etc., complete complying as per standard specification and as directed by by departmental officers
171Supplying, fabricating, erecting and fixing new GYP BOARD FALSE CEILING using 10mm thick plain sheets of approved quality and design suspended from ceiling using "U" shaped GI channels of size 25mmx0.55mm thick at 1.2m c/c on both longitudinal and cross direction for vertical supports and fixing "U" shaped GI channels of size 50mmx30mmx0.55mm thick at 0.90m c/c in cross direction and longitudinal direction respectively for horizontal support by using teak wood reapers at corners and intermediately fixing plaster of paris on the panel provided as per design/pattern given by the site Officer and finishing the ceiling surface with same plaster of Paris materials etc., necessary opening should be made for providing spot light florecent tubes in the ceiling complying with standard specification two coat of distempering and as directed by the Departmental officers.
172Supplying and fixing Gyp-board designed Cornices ofthe edges of the false ceiling wherever necessary as per the direction of the filed officers. The rate includes the cost of materials, transportation charges and fixing charges and other incidental charges etc., the pattern of the cornice has to be approved by the Executive Engineer before used on work etc., complete complying with standard specification and as directed by the departmental officers.
173Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rdfixedglazing2/3rdprelaminatedboard ofAluminiumpartition ofsize2.40 mx 2.40 m.The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 4 mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes inRCC column,masonrywherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing as directed by the departmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineerbefore use.
174Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made ofsection Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 1 No., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge.
175Supplying and fixing of PVC corner beeding of best approved quality and colour standard size and thickness of required height of walls using cement mortar 1:2 (One cement and two sand) and finishing the surface smooth with ceramic tiles etc., complete complying with standard specification and as directed by the departmetal officers.
176Supplying and erecting 3 phase multi stage 2 H.P Submersible Pumpset suitable for 150mm dia Borewell with ISI IS 8034 with 3 phase Panel Board - Star Delta with two level guard and Auto start includingof approved make conforming to ISI.including cost of all accessories, transportation charges, labourcharges for erecting and fixing the motor in position testing as directed by the Departmental Officers complete complying with standard specification. The quality and standard of product should be got approved by the Departmental Officers before erecting. Necessary warranty card should be produced before erection of Motor.
177Supply and fixing in position of PVC mould CI Steps for Sump of suitable size including cost of material, labour and transport charges including dismantling masonry/ rccworks wherever found necessary and making good the damaged portions to the original condition etc., complete complying as per standard specification and as directed by departmental officers.
178Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light / Fan Point (For electronic regulator) etc., complete complying as per standard specification and as directed by departmental officers.
179Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light point.(6 Points Per Coil) (For Rooms like Bath, Toilet & Pump room ) etc., complete complying as per standard specification and as directed by departmental officers.
180Wiring with 3 x 1.5 sq mm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylem sheet covered TW switch box and 5A FT switch (Two way) and making good of the concealed portion with suitable colour for concealed staircase light point etc., complete complying as per standard specification and as directed by departmental officers.
181Supply and fixing of single box type 4"20 W LEDFitting (Higher end ) complete with electronic driver with TW round block on wall or ceiling withLED Tube with PVC unsheathed leads from terminals to the fitting etc.,complete complying as per standard specification and as directed by departmental officers.
182Supply and fixing ofsingle box type 4"20 W LEDFitting (Higher end ) with enamel reflector in suitable AI frame on wall with TW round blocks on wall with LED tube with PVC unsheathed Copper leads from terminals to the fitting chalk board fitting etc., complete complying as per standard specification and as directed by departmental officers.
183Supply and fixing of single box type 4"20 W LED fitting(Higher end) complete with electronic driver with conduit pipe suspension from the ceiling with PVC unsheathed Copper leads from terminals to the fitting with LED tubeetc., complete complying as per standard specification and as directed by departmental officers.
184Supply and fixing of 4"18W twin box type LEDFitting Higher end complete with conduit pipe suspension from the ceiling with 18W crystal glass LED tube with PVC unsheathed leads from terminals to the fitting etc., complete complying as per standard specification and as directed by departmental officers.
185Supply and fixing of WT bulk head fitting with guard (Higher end) suitable for 11W CFL lamp with CFL bulbetc., complete complying as per standard specification and as directed by departmental officers.
186Supply and fixing of 2"x2" 6500K 42W LED recesses mounted square type LED Fitting complete with chain suspension from ceiling, with PVC unsheathed Copper leads from the terminals to the fitting etc., complete complying as per standard specification and as directed by departmental officers.
187Supply and fixing of 2"x2" 6500K 24W LED surface mounted square type LED Fitting complete on ceiling, with PVC unsheathed Copper leads from the terminals to the fittingetc., complete complying as per standard specification and as directed by departmental officers.
188supply and fixing of 30W LED street light fitting with LED (Higher end) with 25 mm dia. GI pipe (class B) with 1 no. 25 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and withpaintingetc., complete complying as per standard specification and as directed by departmental officers.
189Supply and fixing of 1200 mm (48") AC ceiling fancomplete 300W stepped electronic regulator with 500 mm down rod on the existing clampetc., complete complying as per standard specification and as directed by departmental officers.
190Supply and fixing of 1400 mm (56") AC ceiling fancomplete 300W stepped electronic regulator with 500 mm down rod on the existing clampetc., complete complying as per standard specification and as directed by departmental officers.
191Supply and fixing of 375 mm (15") sweep (light duty) AC exhaust fan complete with out provision of hole in the walletc., complete complying as per standard specification and as directed by departmental officers.
192Supply and fixing of louver shutter arrangements for 375mm (15") sweep (light duty) AC exhaust fanetc., complete complying as per standard specification and as directed by departmental officers.
193Supply and fixing of 3 Nos. 5Amps (3 Pin and 2 Pin) combined flush type wall socket with control switches concealed in suitable TW Box covered with Hylem sheet in flush with wall with earth connection ( for computer plug socket) etc., complete complying as per standard specification and as directed by departmental officers.
194Supply and fixing of 5A / 15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable TW Box in flush with wall and covered with 3 mm thick hylum sheetetc., complete complying as per standard specification and as directed by departmental officers.
195Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
196Supply and fixing of 32A DP MCB in suitable sheet steel enclosure inflush with wall with earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
197Supply and fixing of 32A FP MCB in suitable sheet steel enclosure in flush with wall with arth connectionetc., complete complying as per standard specification and as directed by departmental officers.
198Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCBswitch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.HigherEnd etc., complete complying as per standard specification and as directed by departmental officers.
199Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCBIsolatoras incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.HigherEndetc., complete complying as per standard specification and as directed by departmental officers.
200Supply and fixing of 7 segment4 wayTPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. withthe followingin flush with wall with earth connection only. (i)63A 4P MCB- 1 no. (ii)63A 4P 30MA RCCB/ELCB - 1 no. (iii) 63A DP MCB Isolator -3 nos. (iv) 6A to 32A SP MCB - 12 nos. etc., complete complying as per standard specification and as directed by departmental officers.
201Supply and fixing of 7 segment6 wayTPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. withthe followingin flush with wall with earth connection only. (i)63A 4P MCB- 1 no. (ii)63A 4P 30MA RCCB/ELCB - 1 no. (iii) 63A DP MCB Isolator -3 nos. (iv) 6A to 32A SP MCB - 18 nos. etc., complete complying as per standard specification and as directed by departmental officers.
202Supply and Fixing of 3 Ph 4 way Vertical type 160 A 16 KA MCCB DB with IP 43 protection Double door type DB (legrand) with 1No. 125A 4P MCCB 16 KA as incoming and 4 Nos. 63A TP MCB 10 KA as outgoing with cable entry boxes in suitable angle iron frame work with earth connection only. (The MCCB DB, and MCCB"s and MCB"s Like Higher endetc., complete complying as per standard specification and as directed by departmental officers.
203Supply and Fixing of 3 Ph 4 way Vertical type 160 A 16 KA MCCB DB with IP 43 protection Double door type DB (legrand) with 1No. 125A 4P MCCB 16 KA as incoming and 2Nos. 63A TP MCB 10 KA & 2 Nos. 32A TP MCB 10 KA as outgoing with cable entry boxes in suitable angle iron frame work with earth connection only. (The MCCB DB , and MCCB"s and MCB"s Like Higher endetc., complete complying as per standard specification and as directed by departmental officers.
204Supply and run of 2 of 1.5 sq mm (22/0.3) PVC insulated SC unsheathed Cu Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
205Supply and run of 2 of 2.5 sq mm (36/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
206Supply and run of 2 of 4 sq mm (56/0.3) PVC insulated SC unsheathed Cu Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
207Supply and run of 2 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
208Supply and run of 4 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed Cu Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
209Supply and run of 4 of 10 sq.mm (140/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
210Supply and run of 4 of 16 sq.mm (101/0.45) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
211Sub switch Panel: Supply and Erection of 400A capacity Dust and Vermin Proof Cubical Panel Board made up of 16 SWG CRCA steel with supply and fixing of the following interior mounting fuse switches with HRC fuses arranged in two Horizontal rows with one switch over the other with a central bus bar chamber and two nos of Horizontal cable chambers at the two ends one on each side next to the fuse switchchamber and confirming to IE rules. EB INCOMER: 400A FP switch disconnector fuse units interior only with HRC fuse Double Break Switch -1 No DG INCOMER: 400A FP switch disconnector fuse units interior only with HRC fuse Double Break Switch -1 No OUTGOING: 200A TPN switch disconnector fuse units interior only with HRC fuse Double Break Switch -2Nos 125A TPN switch disconnector fuse units interior only with HRC fuse Double Break Switch -6 Nos 63A TPN switch disconnector fuse units interior only with HRC fuse Double Break Switch -2 Nos (All the TPN Switch should be Siemens/ equivalent with Front Handle) with interlocking arrangements. The bus bar chamber will consist of suitable size of tinned copper flat for phase and neutral buses on epoxy moulded bus insulator at proper and sufficient spacing between the buses as per IE Rules. This bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of suitable thickness as partions. 2 Nos 25x3mm tinned copper flats should be provided all round the panel for earth bus.
212The fuse Switches should be connected with the phase and neutral buses with suitable sizeof rigid copper flat/rod and each switch should be connected withthe 2 Nos earth bus with 2 runs of No.8 SWG rigid Tinned copper rod with suitable lugs. Phase and neutral tinned buses should be tinned properly. The panel should have a separate metering chamber at the top side consisting of 0-600V Voltmeter with Selector Switch, 0-400A Ammeter with Selector Switch and C.T arrangement Pilot lamps, toggle switches, fuse unit (Siemens) indicator lamps should be provided with control switches and fuse unit The panelshould be Powder Coat paint of approved colour, approved by the site officer and also the danger board . The capacity of the switches size of incoming and out going cable the place to which the supply is fed shall be mounted on switch chamber. The panel board should be painted on 75mm x37mm MS channel provided all round at bottom of the panel. The whole arrangement should be erected on a masonry pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at aheight of 0.75 m from the ground level with necessary earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
213Supply and laying of 2 Run 3 1/2 X 185 sq.mm PVC armoured LTUG cable in a trench excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand refilling the earth to make goodetc., complete complying as per standard specification and as directed by departmental officers.
214Supply and laying of 2 Run 3 1/2 X 185 sq.mm PVC armoured LTUG cable in Suitable GI pipe to be excavated at a depth of 0.75 metre refilling the earth to make good for road crossingetc., complete complying as per standard specification and as directed by departmental officers.
215Supply and clamping of 2 Run 3 1/2 X 185 sq.mm PVC armoured LTUG cable on post or on wall with MS Clampsetc., complete complying as per standard specification and as directed by departmental officers.
216Supply and fixing of brass cable gland for 3 1/2 X 185 sqmmPVC LTUG armoured cable with earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
217Supply and providing cable end termination of 3 1/2 X 185 sq.mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connectionetc., complete complying as per standard specification and as directed by departmental officers.
218Supply and clamping of 3 1/2 x 300 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clampsetc., complete complying as per standard specification and as directed by departmental officers.
219Supply and clamping of 3 1/2 x 300 sq.mm PVC LTUG armoured LTUG cable in suitable GI pipe on post or on wall with MS Clampsetc., complete complying as per standard specification and as directed by departmental officers.
220Supply and fixing of brass cable gland for 3 1/2 x 300 sqmm PVC armoured LTUG cable with earth connection etc., complete complying as per standard specification and as directed by departmental officers.
221Supply and providing cable end termination of 3 1/2 x 300 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etcwith electrical connectionetc., complete complying as per standard specification and as directed by departmental officers.
222Supply and clamping of 3 1/2 x 50 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clampsetc., complete complying as per standard specification and as directed by departmental officers.
223Supply and fixing of brass cable gland for 3 1/2 x 50 sqmm PVC armoured LTUG cable with earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
224Supply and providing cable end termination of 3 1/2 x 50 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etcwith electrical connectionetc., complete complying as per standard specification and as directed by departmental officers.
225Earthing as per ISI specifications with an earth electrode of 2.1 mtr class "B" GI pipe of dia not less than 40mm with copper plate of size 125mmx50mmx6mm, with necessary funneling arrangements with necessary masonary work and with 38mm RCC cover slab for brick masonaryetc., complete complying as per standard specification and as directed by departmental officers.
226Supply and fixing of 25x3mm copper flat with necessary clamp/ supports on wall / floor / ground for earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
227Supply and Run of1 of No.8 SWG copper wire for earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
228Fabrication, Errection, Testing and commissioning of pedestal mounted pillar box made out of 16SWG CRCA MS Sheet of size 48”x36”x18” out door Type with double compartment and with angle iron stiffener with front open doors for each compartment with lock and key facilities with sealing (TNEB Type) arrangement with dust and Vermin proof and space for fixing TNEB Electronic type energy meter suitable for 3 phase 415 V 4wire 50 HZ AC supply having 400A Capacity Copper Bus bar on suitable bus insulators and provision for mounting 3 Nos C.T.S of 400/5A for incoming to the energy meter and supply and fixing of 3 Nos.400A fuse Units and neutral link on 6mm Thick Hylum sheet and provision for cable entry for both incoming and outgoing cables at the bottom and painting the board with Two coats of anti-corrosive paint of approved colour with earth connection and comprising the following. 1.Digital Voltmeter and Ammeter with suitable Rotary switch 2. LED Indicator light arrangement with suitable push switch and fuse units 3.1 No earth bus of 0.75 mts of 1”x1/8” Copper flat at one side 4. Base channel fixed at the bottom of pillar box 5. View glasses fixedat both compartments 6. Caution / Danger board 7. Meter wiring should be made with identification ferules 8. The whole arrangements should be errected on suitable masonary pedestaletc., complete complying as per standard specification and as directed by departmental officers.
229Supply and fixing of 3 Phase 400A aerial fuse units for 3 Nos. 400A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work with the tapping pole with necessary clampsetc., complete complying as per standard specification and as directed by departmental officers.
230Supply and run of Gong Bell 12" on suitable angle iron frame work with necessary connections and push bell suitable for 230V AC supplyetc., complete complying as per standard specification and as directed by departmental officers.
231Supply and fixing of 400 Amps TPN sheet double break switch with HRC fuse and neutral on suitable angle iron framework with MS cable entry boxes and with earth connection onlyetc., complete complying as per standard specification and as directed by departmental officers.
232Design, supply erection of 20 KVAR 5 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalised out going feeders with suitable capacity MCCB withpanel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming - 100A FP MCCB with rotary handle. Outgoing :5 stage capacitor bank Contactors:Bharatia Cuttler Hammer Heavy Duty contactors. Relays:World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 5 stage from 1 KVAR to 20 KVAR Bus bar: 25 mm x 6mm tinned copper Metering : 1-500A Ammeter with CT coil 2) 0-500V voltmeter. 3) Advance micro controller based intellegent power factor controller with self diagnostic sensing and digital net work analayse with software for monitoring and saving para meter of a suitable multi function meter. Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection etc., complete complying as per standard specification and as directed by departmental officers.
233Supply and Fixing of 3 Ph 4 way Vertical type MCB DB 10 KA with IP 43 protection Double door type DB (legrand) with 1No 63A 4P MCB 10 KA as incoming and 3 Nos. 32A TP MCB 10 KA and 3 Nos. 32A SP MCB 10 KA as outgoing in flush with wall and makinggood of the concealed portion with earth connection only. (The MCB DB and MCB"s should be Like legrand /Hager/L&T /equivalent make) etc., complete complying as per standard specification and as directed by departmental officers.
234Supply and laying of 3 1/2 X 25 sq mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make goodetc., complete complying as per standard specification and as directed by departmental officers.
235Supply and clamping of 3 1/2 X 25 sq mm PVC LTUG armoured LTUG cable on post or on wall with MS Clampsetc., complete complying as per standard specification and as directed by departmental officers.
236Supply and fixing of brass cable gland for 3 1/2 X 25 sq mm PVC armoured LTUG cable, with earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
237Supply and providing cable end termination of 3 1/2 X 25 sq. mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping with electrical connection etc., complete complying as per standard specification and as directed by departmental officers.
238Supply and fixing ofLT cable route indicator with suitable angle not less than 38mm x 38mm x6mm and 0.6mtr long excavation of earth to a depth of 0.6 mtr and concreting the ground level and making good of the groundetc., complete complying as per standard specification and as directed by departmental officers.
239supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colouretc., complete complying as per standard specification and as directed by departmental officers.
240Supply and layingof 4x16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 meter putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make goodetc., complete complying as per standard specification and as directed by departmental officers.
241Supply and laying of 4 x 16 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 meter putting suitable dia. GI pipeand refilling the earth to make goodetc., complete complying as per standard specification and as directed by departmental officers.
242Supply and clamping of 4 x 16 sq.mmPVC LTUG armoured LTUG cableon post with MS Clampsetc., complete complying as per standard specification and as directed by departmental officers.
243Supply and clamping of 4x16sq.mm PVC LTUG armoured LTUG cable through 40mm dia G.I pipe on post or on wall with MS Clampsetc., complete complying as per standard specification and as directed by departmental officers.
244Supply and fixing of brass cable gland for 4X16 sq.mm PVC LTUG armoured cablewith earth connectionetc., complete complying as per standard specification and as directed by departmental officers.
245Sub Total
246GST
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail