Tender For Construction Of Block Public Health Unit At C.H.C. Pahadi At District Chitrakoot, (U.P.), chitrakoot-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Tender For Construction Of Block Public Health Unit At C.H.C. Pahadi At District Chitrakoot, (U.P.). Submission Date for this Tender is 30-03-2024. Building Work Tenders in chitrakoot Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42916279
Tender For Construction Of Block Public Health Unit At C.H.C. Pahadi At District Chitrakoot, (U.P.)
Open Tender
Indian
Uttar Pradesh
chitrakoot
30-03-2024

Tender Details

Construction Of Block Public Health Unit At C.H.C. Pahadi At District Chitrakoot, (U.P.)

Key Value

Document Fees
INR 11800 /-
EMD
INR 105000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of Block Public Health Unit at C.H.C. Pahadi at District Chitrakoot, (U.P.)
Sl. No. Item Description
1Construction of Block Public Health Unit at C.H.C. Pahadi at District Chitrakoot, (U.P.)
2Boring with hydraulic piling rigs with power units, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles
3Earth work in exacavation in foundations in ordinary soil (loam clay or sand) including lift upto 1.5 m and lead upto 30 mt. & including filling, watering and ramming of excavated earth into the trenches or into the space between building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 mt. from the foundation trenches.Filling of earth in plinth in 20cm layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer incharge..
4Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand.
5Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone ballast 40 mm nominal size) and curing complete, including cost of form- work, in foundation.
6Construction of apron drain along apron (150X150)MM
7Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer"s standard dilution)
8Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
9Upto plinth level
10(i) R.C.C. work in Footing
11(ii) R.C.C. work in Beam
12Above plinth to floor-V lvl
13Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
14(iii) R.C.C. work in Columns
15(i) R.C.C. work in Lintel
16(ii) R.C.C. work in Beam
17(iv) R.C.C. work in Slab
18Centering and shuttering including strutting, propping etc. and removal of form for all heights :
19Foundations, footings, bases of columns, etc. for mass concrete.
20Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick
21Columns,Pillars, Piers, Abutments, Posts and Struts.
22Edges of slabs and breaks in floors and walls Under 20 cm wide.
23M-150 brick work in 1:4 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, T & P etc required for proper completion of the work.
24M-150 brick work in 1:4 cement and coarse sand of 2.25 fineness modulus above but in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms.
25M-150 brick work in 1:4 cement and coarse sand of 2.25 fineness modulus in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
26Providing & applying a coat of residual petroleum bitumen of grade ofVG-10 of approved quality using 1.7kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
27Providing and laying "brick coba" 120 mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement & coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm & side wall parapet shall be mono lythic plaster wall up to 30 cm higher
28and junction & corner shall be rounded by brick ballast cement & coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
29TMT Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
30Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) with glazing
3115 mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand.
3212mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6coarse sand
3312 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80mm in girth & finshed even & smooth. (1) 1 cement : 6 coarse sand
34Making grooves 10 to 12mmwide xam deep in plaster of the walls or in ceiling vertically or horizontally as required.
35Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
36Providing and laying 6 to 8 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
37Providing and laying vitrified floor tiles Kajaria KERRO Brand or Equivalent brand off super quality in different size (thickness specified by manufacture) with water absorption less than 0-8% and confirming to IS 15622 of approved make in colors & shade laid on 20mm thick cement mortar 1:4 (1 cement 4 coarse sand) including grouthing the joints with white cement and matching pigments etc,complete.( Size of tiles600x600mm) (Anti skid/mat finished tile)
38Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, anitycounters, window sills , facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red
39Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
40Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc.
41Supply and fixing 6mm thick china white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc.
42Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
43Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.
44Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
45Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
46Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)
47Providing and fixing false ceiling at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiels of size 595x595 mm of approved texture ,design and patterns having molsture content less trhan 2% ,humidity resistance of 99 % NRC 0.50 to 0.75 as per IS 8225:1987,Non combusitable as per BS 476 (part 4)-1970 and light reflectance of 85% (minium) to be laid in true horizontal level suspended on inter locking metal T-grid of hot dipped gavanised iron section of 0.33 mm thick (galvanizing @ 120 gram per sqm including bothside ) comprising of main -T runners of size 15x32 mm of length 3000 mm ,cross -T of size 15x32 mm of length 1200 mm and secondary intermediate cross -T of size 15x32 mm of length 600mm to form grid module of size 600x 600 mm suspended from ceiling using galvanished mild steel item (galvanished @ 80 grams per sqm )i.e.50 mm long ,8mm outerdiameter M-6 dash fasteners 6 mm dia fully threaded hanger rod upto 1000 mm length and l shade level adjuster of size 85x25x2 mm.Galvanishediron perimeter wall angle of szie 24x24x0.40 mmm of length 3000 mm to be fixed on periphery wall/ partitionwith the help of plastic rawl pulgs at 450mm center to center and 40mm long dry wall wood screws.The work shall be carried out as per specfication ,drawing and as per directions of the Engineer in charge with semi perforated 12 mm thick regular edged GRG false ceiling tiels.
48PLUMBING WORKS
49Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
50Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white plastic seat and lid
51Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.
52Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040x200mm
53Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete,including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
54Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.
55Semi rigid pipe
56a) 32mm dia
57b) 40mm dia
58Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
59Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore
60Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms.
61Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter
62Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
63Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
64Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
65Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall 25mm dia nominal bore
66Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 25mm dia nominal bore.
67Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
68internal work -Exposed on wall
6920mm dia nominal outer dia pipes
7025mm dia nominal outer dia pipes
71Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.
7215mm dia nominal outer dia pipes
7320mm dia nominal outer dia pipes
7425mm dia nominal outer dia pipes
75Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore
76Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore
77Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore
78Providing and fixing gun metal gate valve with wheel of approved quality.
7925mm dia nominal bore
8020 mm dia nominal bore
81Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
82Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
83Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia.
84Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.
85100mm diameter
86150mm diameter
87Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
88100mm diameterS.W. Pipe
89150mm diameterS.W. Pipe
90Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885
91Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line
92Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar
93ELECTRICAL WORKS
94Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
95Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required.
962X1.5 sqmm + 1x1.5 sqmm earth wire
972X2.5 sqmm + 1x 2.5 sqmm earth wire
982X4.0 sqmm + 1x 4.0 sqmm earth wire
992X6.0 sqmm + 1x 6.0 sqmm earth wire
100Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
101Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 20mm
102Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet
103Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
104Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
105Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required.
1061 or 2 module(75mm X 75 mm )
107Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required.
108Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required.
109Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required.
110Supplying and fixing brass batten/angle holder including connectionetc. as required.
111Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
112Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required.
113Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
114Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
115Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required.upto 450 mm sweep.
116Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
117Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required.
118Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
119Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM /M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
120Supplying and fixing followingway, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess completewith , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators).12 way, Double door
121Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C" series,miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.
122Single Pole
123Double Pole
124Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
125Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure withcover platehavinglockingarrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required.
126Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
127Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required.
128Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
129Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sqmm. (19mm)
130Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 50 mm Dia(Rate taken From Civil DSR 2021-18.12)
131Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554.
13210 sqmm 2 core
133Supply and erection of1X10 W mirror light complete in all respects
134Supply & fixing of7/9 W LED BULB complete in all respect.
135Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect.
136Supply & fixing ofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. Cat AAA
137Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.-Make: Havells-STANDARD -Refresh Air-SPS 300mm sweep.
138MAIN L.T. PANEL
139Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm CUBICAL PANEL BOARD ( MCCB TYPE ) SUB PANEL Incoming : one (1)No.200Amp. MCCB-1No. Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No.200 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 100 Amp. MCCB- 1 No. 63 Amp. MCCB- 3 No. OR outgoing as per site requirment(AS/SLD)
140SEPTIC TANK SIZE OF TANK :- Length = 5.00 M. Width = 2.00 Total Depth =3.00M
141Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality).
142From 0.00 mt to 1.50 mt
1431.50mt to 3.0 mt
1443.0 mt to 4.50 mt
145Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors.
146R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. As in item no. 3above but for slabs (Using 1:1.5:3 Mix concrete)
147M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
148P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
149Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
15015 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 Coarse sand
151Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729
152Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar)
153Providing and fixing C.I. tee at the inlet and outlet of septic tank.
154Providing & fixing of 75mm dia cast iron terminal guard.
155Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
156M.D. -10- Circular shape 500mm internal diameter
157L.D. -2.5- Circular shape 450mm internal diameter
158Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation M-150
159INTERLOCKING ( 60.00 SQM)
160Earth work in exacavation in trenches for foundations pipes cables etc. in ordinary soil (loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m. (2.8.1)
161Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors.(-4.1.8)
162M-150 brick work in 1:4 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour, T & P etc required for proper completion of the work.( 6.1.1)
163Interlocking Tiles-Rubbermouldedrefiective Zig-Zag 80mm Providing and laying of Interlocking Concrete Block Laying ofPavements having thickness 80mm including levelling and dressing of surface to required level and slope, spreading and moisting 30m thick local sand on bend, filling joints with local sand on bend, filling joints with local sand etc for proper completion of the work as per drawing and technical specification clause 16.91.2
164GST Extra as per applicable
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail