}

Tender For Rate Contract For Supply Of Different Types Of Led Lights For Maintenance Of E.I In Various Buildings In Mdu, Rohtak, rohtak-Haryana

Maharshi Dayanand University-MDU has published Tender For Rate Contract For Supply Of Different Types Of Led Lights For Maintenance Of E.I In Various Buildings In Mdu, Rohtak. Submission Date for this Tender is 03-04-2024. Brackets and Braces Tenders in rohtak Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42912480
Tender For Rate Contract For Supply Of Different Types Of Led Lights For Maintenance Of E.I In Various Buildings In Mdu, Rohtak
Open Tender
Indian
Haryana
rohtak
03-04-2024

Tender Details

Rate Contract For Supply Of Different Types Of Led Lights For Maintenance Of E.I In Various Buildings In Mdu, Rohtak , Supply Of Recess Mounted 36W Led Flat Panel 600 Mm X 600 Mm, Lumen Of Above In Cool Day Light ( 5700K To 6500K ) . Average Life ) = 50000 Hrs. Power Factor = 0.95, Cri = 80, Led Lamp Efficiency ) = 100 Lm / Watt, System Lumen Should Be 3600 Or Above, Voltage Range 140V -270V And Glare Free Opal Diffuser And Housing Made Of Crca Sheet Steel Finishing With Epoxy Powder Coating. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation. Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 20W Led Round Batten With Co-Extruded Polycarbonate Housing . Total System Lumen Of 20W Led Should Be 2000 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.9, Cri ( Ra ) >80, Average Life Of Led >50000Hr Led Lamp Efficacy>130 Lm / W. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation. Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 10W Led Round Batten With Co-Extruded Polycarbonate Housing . Total System Lumen Of 10W Led Should Be 1000 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.9, Cri ( Ra ) >80, Average Life Of Led >50000Hr Led Lamp Efficacy>130 Lm / W. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation. Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 18W Led Tube Rod T5 With Aluminium Heat Sink Forefficient Heat Dissipation Housing. Total System Lumen Of 18W Led Should Be 1840 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.9, Cri ( Ra ) >80 Thd <20%, Average Life Of Led >50000Hr Led Lamp Efficacy>140 Lm / W Led Chip Lumen Efficacy Of 140 Lm / W. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation.Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 20W Led Tube Rod T8 With Polycarbonate Housing . Total System Lumen Of 20W Led Should Be 2000 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.9, Cri ( Ra ) >80 Thd <15%, Average Life Of Led >50000Hr Led Lamp Efficacy>130 Lm / W Led Chip Lumen Efficacy Of 140 Lm / W Surge Voltage Protection Upto 3 Kv. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation. Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 45 Watt Led Street Light With Ip66 Multiple Led With Lens Optics And Pressure Die-Cast Aluminium Housing For Effective Thermal Management . Total System Lumen Of 45W Led Should Be 4700 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.95, Cri ( Ra ) >80, Thd <10%, Average Life Of Led >50000Hr Led Lamp Efficacy>140 Lm / W With 3 Kva Spd Inbuilt Smps Driver. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation.Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 70 Watt Led Street Light Fitting As Per Entire Satisfaction Of The Engineer In Charge With Following Specifications: Led Street Light Of System Wattage 70 Watt Ip 66 Multiple Led With Lens Optics With Electric Driver And Pressure Di-Cast Aluminium Housing For Effective Thermal Management. Total System Lumen 70 W Led Should Be 8000 Lumen Or Above In Cool Day Light ( 5700-6500K ) , Lumen Efficiency ) 115Lm / W, Power Factor ) 0.95, Cri ( 70, Average Life ) 5000 Hours Open / Short Circuit Protection, Over Voltage Protection, Surge Protection With Spd ( 10Kv ) . Complete Mounting Brackets And Accessories As Required With Connections With Two Year Warranty And Complete In All Respect Up To The Entire Satisfaction Of Engineer-In- Charge. Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 150W Led Flood Light With Ip66 Multiple Led With Lens Optics And Powder Coated Die-Cast Aluminium Housing For Effective Thermal Management . Total System Lumen Of 150W Led Should Be 18000 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.95, Cri ( Ra ) >80, Thd <10%, Average Life Of Led >50000Hr Led Lamp Efficacy>140 Lm / W With 10Kva Spd Inbuilt And Driver Should Be Potted Ip67. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation.Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 200W Led Flood Light With Ip66 Multiple Led With Lens Optics And Powder Coated Die-Cast Aluminium Housing For Effective Thermal Management . Total System Lumen Of 200W Led Should Be 24000 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.95, Cri ( Ra ) >80, Thd <10%, Average Life Of Led >50000Hr Led Lamp Efficacy>140 Lm / W With 10Kva Spd Inbuilt And Driver Should Be Potted Ip67. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation. Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 250W Led Flood Light With Ip66 Multiple Led With Lens Optics And Pressure Die-Cast Aluminium Housing For Effective Thermal Management . Total System Lumen Of 250W Led Should Be 27500 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.95, Cri ( Ra ) >80, Thd <10%, Average Life Of Led >50000Hr Led Lamp Efficacy>145 Lm / W With 10Kva Spd Inbuilt And Driver Should Be Potted Ip67. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation. Make : Bajaj / Havells / Orient / Surya Roshni , Supply Of 350W Led Flood Light With Ip66 Multiple Led With Lens Optics And Pressure Die-Cast Aluminium Housing For Effective Thermal Management . Total System Lumen Of 350W Led Should Be 35000 Or Above In Cool Day Light ( 5600K To 6500K ) , Power Factor>0.95, Cri ( Ra ) >70, Thd 50000Hr Led Lamp Efficacy>135 Lm / W With 10Kva Spd Inbuilt And Driver Should Be Potted Ip67. Complete With All Accessories As Required With Connections. Complete In All Respect To The Satisfaction Of Engineer-In-Charge. All Test Report And Sample Should Be Passed Through Department Before Installation. Make : Bajaj / Havells / Orient / Surya Roshni

Key Value

Document Fees
INR 1000 /-
EMD
INR 47420.0 /-
Tender Value
INR 23.71 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail