Bharat Sanchar Nigam Limited-BSNL has published Tender For Construction Of 13 Buildings At Various Locations In India For Unified Network Management System Unms S.H. - Supply And Installation Of Fire Rated Door At 10 Different Location In India.. Submission Date for this Tender is 26-03-2024. Building Work Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Mar-2024 | Corrigendum | Other | 20-03-2024 |
2 | 20-Mar-2024 | Corrigendum for Date extension | Date | 26-03-2024 |
3 | 21-Mar-2024 | Corrigendum03 | Financial Bid | 26-03-2024 |
Sl. No. | Item Description |
1 | Providing and fixing fully Glazed GS Sheet 2 hr Fire rated doors at all floor levels in the existing opening available at site ) and of sizes as per relevant arch drgs with specifications as below and as per directions of Engineer-in-charge. All Fire rated doors must satisfy for 120 minutes Fire Rating for its Stability & Integrity as per BIS 3614:2021. All Fire rated doors should be finished as specified in the relevant architectural drawings . The FRD to be fixed in the existing opening may require minor alteration in the opening in form of making true horizontal/vertical. The responsibility of the same remains with the agency and nothing extra shall be paid on this account . |
2 | Door frame shall with inbuilt rebate shall be of profile of minimum size Top Horizontal (50X60) mm and side Vertical (35X60) mm made out of 1.60 mm thick galvanized steel sheet (Zinc coating not less than 120 gm/sqm). Frames shall be Butt jointed and assembled with bolting system for strength. Frames should be provided with back plate for installation on a finished plastered wall opening with anchor fasteners of approved make and size as per direction of E-I-C.The infill material shall be Mineral wool insulation infill treated with VIPER FRS 881 LH density 96 Kg/m3 or prototype test report carried out from CBRI Roorkee as per BS476 part 20 & 22 . |
3 | Door leaf shall be minimum 60 mm thick double skin box type door shutter framing with Top Rail & Vertical Stile of size 100x60 mm and Bottom Rail 200x60 mm made out of 1.2 mm thick galvanised steel sheet (Zinc coating not less than 120 gm/sqm) and 11 mm thick glass panel of clear, toughened, non-wired, fire resistant glass with 120 minutes of fire resistance of approved brand, fixed with GI beading made out of 1.6 mm thick GS sheet (Zinc coating not less than 120 gm/sqm) and finish as specified in relevant Architectural drawing & special ceramic tape of appropriate size etc complete. The internal construction of the door shutter frame should be rigid reinforcement pads for receiving appropriate hardware. The infill material for shutter framing shall be mineral wool insulation infill treated with VIPER FRS 881 LH or as per prototype test report from CBRI Roorkee or reputed international lab, In case the test is not conducted by CBRI Roorkee. For Double leaf doors astragal shall to be provided on the meeting stile for both active and inactive leaf. The glass shall be able to withstand fire attack from both sides. The manufacturer shall give test report/certification of Fire Glass and the glass should have stamp showing value of fire rating. Shutter shall be fixed to frame with SS 304 ball bearing hinges of approved make as per direction of E-I-C. |
4 | The FRD door shall be fixed with Overhead Door closers, Panic bar, panic trim, Motise Sash Lock and other fittings as per approved shop drawing and as per direction of E-I-C. |
5 | The rate includes the costs of all materials and labour involved in manufacturing, supplying and fixing in position in existing door opening at floor level of all sizes complete door assembly for all leads and lifts and includes the cost of sample door with all fittings per lot to be sent for mandatory testing as per provisions in the agreement and as directed by Engineer In Charge. The rate includes Hinges ,fasteners, Intumescent Seal, Smoke seal, Insulation material in frame and shutter stile. However, the following fittings shall be paid separately Overhead Door closure, Floor socket, Panic Bar, Panic trim, Extension rod, mortice lock, SS concealed slash bolt etc. Nothing extra shall be paid beyond this. Note: The door must carry a Batch sticker with details of the door after scanning. |
6 | The shop drawings shall be submitted by agency for approval within 7 days of issue of award letter. The section, size of the frame/shutter and thickness of sheet shall not be less than the Size, section and the thickness of the sheet of tested proto FRD door from CBRI or international reputed lab. If the specification of the proto is richer/higher than the specification mentioned in the schedule than the specification as per the proto shall be followed , and nothing extra shall be paid. If the specification of the proto tested from the CBRI or reputed international lab, In case the test is not conducted by CBRI Roorkee is lesser than the specification mentioned in the schedule as above than the specification as per schedule as above shall be followed and nothing extra shall be paid . Quote the rate accordingly. |
7 | (a) NNC Delhi with RAL 7035 finish on frame and RAL 9003 for shutter |
8 | (b) DRNC Bengaluru with RAL 7035 finish on frame & RAL 9003 for Shutter. |
9 | (e) RNC Chandimandir with powder coating of natural Teak finish for both frame & shutter |
10 | (f) RNC Jaipur with powder coating of natural Teak finish for both frame & shutter |
11 | (g) RNC Pune with powder coating of natural Teak finish for both frame & shutter |
12 | (h) RNC Lucknow with powder coating of natural Teak finish for both frame & shutter |
13 | (i) RNC Kolkata with powder coating of natural Teak finish for both frame & shutter |
14 | (j) RNC Udhampur with powder coating of natural Teak finish for both frame & shutter |
15 | Uninsulated Metallic fire rated door |
16 | Providing and fixing Metallic Un-Insulated GS Sheet 2 hr Fire rated doors at all floor levels in the existing opening available at site ) and of sizes as per relevant arch drgs with specifications as below and as per directions of Engineer-in-charge. All Fire rated doors must satisfy for 120 minutes Fire Rating for its Stability & Integrity as per BIS 3614:2021. All Fire rated doors should be finished as specified in the relevant architectural drawings . The FRD to be fixed in the existing opening may require minor alteration in the opening in form of making true horizontal/vertical. The responsibility of the same remains with the agency and nothing extra shall be paid on this account . |
17 | Door frame of size (125X 55 ) mm with inbuilt rebate profile made out of 1.60 mm thick galvanized steel sheet (Zinc coating not less than 120 gm/sqm) . Frames shall be Butt jointed and assembled with bolting system for strength. Frames should be provided with back plate for installation on a finished plastered wall opening with anchor fasteners of approved make and size as per direction of E-I-C. The Frame shall be filled up with suitable fire rated infill material in both Horizontal and vertical as per prototype test report carried out from CBRI Roorkee as per BS 476 part 20 &22 . |
18 | Door leaf single/double should be 60 mm thick fully flush double skin, manufactured from 1.2mm thick galvanised steel sheet and shall be provided with reinforcement pads & necessary provision for receiving appropriate Hardware. The Shutter shall be filled with infill material honey comb kraft paper density 180 GSM or proprietary infill material insulation as per prototype test report carried out from CBRI Roorkee as per BS 476 part 20 & 22. Double leaf doors will have astragal at their meeting stile for both active and inactive leaf. Vision panels wherever required should be of 120 minutes fire rating. The glass of vision panel shall be clear , toughened, non wired fire resistant of 6 mm thickness of SAINTGOBAIN/ PYROBECK /EQ approved brand with 120 minutes of fire resistance. The glass shall be able to withstand fire attack from both side. The manufacturer shall give test report/certification of Fire Glass and the glass should have stamp showing value of fire rating. Shutter shall be fixed to frame with SS 304 ball bearing hinges of approved make as per direction of E-I-C. The door frame and shutter shall be finished with powder coating as per arch drawings and as approved by engineer-in-charge. |
19 | The provision for Overhead Door closer , EPDM seal and smoke seal, the Mortise Sash Lock with both side key & SS Lever handle of 80 mm BSK Cylinder of Dorma make or equivalent, SS Concealed 600 mm Flush Bolt on top/bottom and 300 mm long SS Concealed flush bolt at bottom/top, floor Socket in double leaf door, vision Panel in each leaf of the door shall be provided as per approved drawing. |
20 | The rate includes the costs of all materials and labour involved in manufacturing, supplying and fixing in position in existing door opening at floor level of all sizes complete door assembly for all leads and lifts and includes the cost of sample door with all fittings per lot to be sent for mandatory testing as per provisions in the agreement and as directed by Engineer In Charge. The rate includes Hinges ,fasteners, Intumescent Seal, Smoke seal, Insulation material in frame and shutter stile. However, the following fittings shall be paid separately Overhead Door closure, Floor socket, Panic Bar, Panic trim, Extension rod, Vision Panel, mortice lock,SSconcelled slash bolt etc. Nothing extra shall be paid beyond this. Note: The door must carry a Batch sticker with details of the door after scanning. |
21 | The shop drawing shall be submitted by agency for approval within 7 days of issue of award letter. The section, size of the frame/shutter and thickness of sheet shall not be less than the Size, section and the thickness of the sheet of tested proto FRD door from CBRI . If the specification of the tested proto FRD is richer/higher than the specification mentioned in the schedule than the specification as per the tested proto shall be followed , and nothing extra shall be paid. If the specification of the tested proto from the CBRI is lesser than the specification mentioned in the schedule as above than the specification as per schedule as above shall be followed and nothing extra shall be paid . Quote the rate accordingly. |
22 | (a) NNC Delhi with RAL 7035 finish on frame and RAL 9003 for shutter |
23 | (b) DRNC Bengaluru with RAL 7035 finish on frame & RAL 9003 for Shutter. |
24 | (c) NLDC Delhi with with RAL 7035 finish on frame & RAL 9003 for Shutter. |
25 | (d) DRNLDC Bengaluru with RAL 7035 finish on frame & RAL 9003 for Shutter. |
26 | (e) RNC Chandimandir with powder coating of natural Teak finish for both frame & shutter |
27 | (f) RNC Jaipur with powder coating of natural Teak finish for both frame & shutter |
28 | (g) RNC Pune powder with powder coating of natural Teak finish for both frame & shutter |
29 | (h) RNC Lucknow with powder coating of natural Teak finish for both frame & shutter |
30 | (i) RNC Kolkata with powder coating of natural Teak finish for both frame & shutter |
31 | (j) RNC Udhampur with powder coating of natural Teak finish for both frame & shutter |
32 | Insulated Metallic fire rated door |
33 | Providing and fixing Metallic Insulated GS Sheet 2 hr Fire rated doors at all floor levels in the existing opening available at site and of sizes as per relevant arch drgs with specifications as below and as per directions of Engineer-in-charge. All Fire rated doors must satisfy for 120 minutes Fire Rating for its Stability & Integrity and thermal insulation as per BIS 3614: 2021 . All Fire rated doors should be finished as specified in the relevant architectural drawings . The FRD to be fixed in the existing opening may require minor alteration in the opening in form of making true horizontal/vertical. The responsibility of the same remains with the agency and nothing extra shall be paid on this account . |
34 | Door frame of size (125X 75 ) mm with inbuilt rebate profile made out of 1.60 mm thick galvanized steel sheet (Zinc coating not less than 120 gm/sqm) . Frames shall be Butt jointed and assembled with bolting system for strength. Frames should be provided with back plate for installation on a finished plastered wall opening with anchor fasteners of approved make and size as per direction of E-I-C. The Frame shall be filled up with suitable fire rated infill material in both Horizontal and vertical as per prototype test report carried out from CBRI Roorkee as per BS 476 part 20 &22 . |
35 | Door leaf single/double should be 60 mm thick fully flush double skin, manufactured from 1.2mm thick galvanised steel sheet and shall be provided with reinforcement pads & necessary provision for receiving appropriate Hardware. The Shutter shall be filled with infill material Mineral wool insulation treated with VIPER FRS 881 LH density 96 Kg/m3 or proprietary infill material insulation as per prototype test report carried out from CBRI Roorkee as per BS 476 part 20 & 22. Double leaf doors will have astragal at their meeting stile for both active and inactive leaf. Vision panels wherever required should be of 120 minutes fire rating. The glass of vision panel shall be clear , toughened, non wired fire resistant of 6 mm thickness of SAINTGOBAIN/ PYROBECK /EQ approved brand with 120 minutes of fire resistance. The glass shall be able to withstand fire attack from both side. The manufacturer shall give test report/certification of Fire Glass and the glass should have stamp showing value of fire rating. Shutter shall be fixed to frame with SS 304 ball bearing hinges of approved make as per direction of E-I-C. The door frame and shutter shall be finished with powder coating as per arch drawings and as approved by engineer-in-charge. |
36 | The provision for Overhead Door closer, Panic bar (single/triple) with extension rod if required , panic trim , EPDM seal and smoke seal, the Mortise Sash Lock with both side key & SS Lever handle of 80 mm BSK Cylinder of Dorma make or equivalent, SS Concealed 600 mm Flush Bolt on top/bottom and 300 mm long SS Concealed flush bolt at bottom/top, floor Socket in double leaf door, vision Panel in each leaf of the door shall be provided as per approved drawing. |
37 | The rate includes the costs of all materials and labour involved in manufacturing, supplying and fixing in position in existing door opening at floor level of all sizes complete door assembly for all leads and lifts and includes the cost of sample door with all fittings per lot to be sent for mandatory testing as per provisions in the agreement and as directed by Engineer In Charge. The rate includes Hinges ,fasteners, Intumescent Seal, Smoke seal, Insulation material in frame and shutter. However, the following fittings shall be paid separately Overhead Door closure, Floor socket, Panic Bar, Panic trim, Extension rod, Vision Panel, mortice lock, SS concealed slash bolt etc. Nothing extra shall be paid beyond this. Note: The door must carry a Batch sticker with details of the door after scanning. |
38 | The shop drawing shall be submitted by agency for approval within 7 days of issue of award letter. The section, size of the frame/shutter and thickness of sheet shall not be less than the Size, section and the thickness of the sheet of tested proto FRD door from CBRI . If the specification of the tested proto FRD is richer/higher than the specification mentioned in the schedule than the specification as per the tested proto shall be followed , and nothing extra shall be paid. If the specification of the tested proto from the CBRI is lesser than the specification mentioned in the schedule as above than the specification as per schedule as above shall be followed and nothing extra shall be paid . Quote the rate accordingly. |
39 | (a) NNC Delhi with RAL 7035 finish on frame and RAL 9003 for shutter |
40 | (b) DRNC Bengaluru with RAL 7035 finish on frame & RAL 9003 for Shutter. |
41 | (e) RNC Chandimandir with powder coating of natural Teak finish for both frame & shutter |
42 | (f) RNC Jaipur with powder coating of natural Teak finish for both frame & shutter |
43 | (g) RNC Pune with powder coating of natural Teak finish for both frame & shutter |
44 | (h) RNC Lucknow with powder coating of natural Teak finish for both frame & shutter |
45 | (i) RNC Kolkata with powder coating of natural Teak finish for both frame & shutter |
46 | B) Fitting and fixtures |
47 | Providing and fixing SS touch type Panic bar Triple point of make backer fire solutions or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
48 | (a) NNC Delhi |
49 | (b) DRNC Bengaluru |
50 | (c) RNC Chandimandir |
51 | (d) RNC Jaipur |
52 | (e) RNC Pune |
53 | (f) RNC Lucknow |
54 | (g) RNC Kolkata |
55 | Providing and fixing SS 304 extension rod above 2270mm of make backer fire solutions or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
56 | (a) NNC Delhi |
57 | (b) DRNC Bengaluru |
58 | (c) RNC Chandimandir |
59 | (d) RNC Jaipur |
60 | (e) RNC Pune |
61 | (f) RNC Lucknow |
62 | (g) RNC Kolkata |
63 | Providing and fixing panic trim half cylinder SS finish make backer fire solutions or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
64 | (a) NNC Delhi |
65 | (b) DRNC Bengaluru |
66 | (e) RNC Chandimandir |
67 | (f) RNC Jaipur |
68 | (g) RNC Pune |
69 | (h) RNC Lucknow |
70 | (i) RNC Kolkata |
71 | Providing and fixing in position in 2 hr fire rated door of all type Fully Glazed/ Metallic with vision panel door closer make Dorma TS 68 STND ARM or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
72 | (a) NNC Delhi |
73 | (b) DRNC Bengaluru |
74 | (c) NLDC Delhi with |
75 | (d) DRNLDC Bengaluru |
76 | (e) RNC Chandimandir |
77 | (f) RNC Jaipur |
78 | (g) RNC Pune |
79 | (h) RNC Lucknow |
80 | (i) RNC Kolkata |
81 | (j) RNC Udhampur |
82 | Providing and fixing concealed flush bolt in bottom/Top for Glazed / metal door 300mm make Dorma (Article No.9114306) or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
83 | (a) NNC Delhi |
84 | (b) DRNC Bengaluru |
85 | (c) NLDC Delhi with |
86 | (d) DRNLDC Bengaluru |
87 | (e) RNC Chandimandir |
88 | (f) RNC Jaipur |
89 | (g) RNC Pune |
90 | (h) RNC Lucknow |
91 | (i) RNC Kolkata |
92 | (j) RNC Udhampur |
93 | Providing and fixing concealed flush door bolt on top/bottom for metal door 600mm make Dorma (Article No.9114320) or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
94 | (a) NNC Delhi |
95 | (b) DRNC Bengaluru |
96 | (c) NLDC Delhi with |
97 | (d) DRNLDC Bengaluru |
98 | (e) RNC Chandimandir |
99 | (f) RNC Jaipur |
100 | (g) RNC Pune |
101 | (h) RNC Lucknow |
102 | (i) RNC Kolkata |
103 | (j) RNC Udhampur |
104 | Providing and fixing SS 304 floor socket make Dorma or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
105 | (a) NNC Delhi |
106 | (b) DRNC Bengaluru |
107 | (c) NLDC Delhi with |
108 | (d) DRNLDC Bengaluru |
109 | (e) RNC Chandimandir |
110 | (f) RNC Jaipur |
111 | (g) RNC Pune |
112 | (h) RNC Lucknow |
113 | (i) RNC Kolkata |
114 | (j) RNC Udhampur |
115 | Providing and fixing 6mm thick vision panel 200mmX300mm make Saint Gobin or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
116 | (a) NNC Delhi |
117 | (b) DRNC Bengaluru |
118 | (e) RNC Chandimandir |
119 | (f) RNC Jaipur |
120 | (g) RNC Pune |
121 | (h) RNC Lucknow |
122 | (i) RNC Kolkata |
123 | Providing and fixing 6mm thick vision panel 150 mmX800mm or 150 mm X 600 mm make Saint Gobin or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
124 | (a) NNC Delhi |
125 | b) DRNC Bengaluru |
126 | (c) NLDC Delhi with |
127 | (d) DRNLDC Bengaluru |
128 | (e) RNC Chandimandir |
129 | (f) RNC Jaipur |
130 | (g) RNC Pune |
131 | (h) RNC Lucknow |
132 | (i) RNC Kolkata |
133 | (j) RNC Udhampur |
134 | Providing and fixing inposition in 2 hr fire rated door Fully Glazed/GI Sheet metallic door mortise sash lock ( Consisting of Euro Profile cylinder both side key L - 80 mm , SNP (Article No 9113917), Pure 8100 Lever Handle with Finish: Satin (Article no: 90050055010) & 281 Sash Lock Basket -55 mm C/C -72 mm, 20 mm square forend Strike plate, SS 304, Finish: SSS Fire Rated Article no 51200337) of Dorma Make or equivalent having 2 hr fire rating or as per the tested proto type FRD with complete assembly all complete as approved by the Engineer-in-charge. Nothing extra or deduction shall be made on account of variation in the brand and make. |
135 | (a) NNC Delhi |
136 | b) DRNC Bengaluru |
137 | (c) NLDC Delhi with |
138 | (d) DRNLDC Bengaluru |
139 | (e) RNC Chandimandir |
140 | (f) RNC Jaipur |
141 | (g) RNC Pune |
142 | (h) RNC Lucknow |
143 | (i) RNC Kolkata |
144 | (j) RNC Udhampur |
145 | Making the surface good and finish the Jambs, sill, soffit etc of the door opening portion after installation of the FRD of all sizes. The finish of the surface should match with the existing adjacent area finish thereon. The outer jamb finish shall be matching with the outer adjacent wall and inner jambs as per inner wall finish. The gaps between the frame of the FRD and the wall or the sill and soffit should be filled with any suitable sealant as per BIS 3614:2021. |
146 | (a) NNC Delhi |
147 | b) DRNC Bengaluru |
148 | (c) NLDC Delhi with |
149 | (d) DRNLDC Bengaluru |
150 | (e) RNC Chandimandir |
151 | (f) RNC Jaipur |
152 | (g) RNC Pune |
153 | (h) RNC Lucknow |
154 | (i) RNC Kolkata |
155 | (j) RNC Udhampur |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail