Police Department-PD has published Tender For Supply And Installation Of Cctv Camera Surveillance. Submission Date for this Tender is 04-04-2024. CCTV System Tenders in thrissur Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Mar-2024 | Date Corrigendum | Date | 04-04-2024 |
Sl. No. | Item Description |
1 | Supply and installation of CCTV Camera, Surveillance, Data Storage Centre and other necessary equipments in Thrissur LAC |
2 | LED Wall - 55” Large format proffessional display 24x7 (Warranty & Onsite Support 5 Years) |
3 | SITC of3KVA/2400W Online UPS Systems Floor Mountable, Double conversion Pure sine wave Online UPS System (72VDC) connecting in Floor Mountable, Double conversion Pure sine wave Online UPS System (72VDC) connecting in Standalone Configuration with 60minutes backup, battery using 12 V VRLA SMF batteries Standalone Configuration with 60minutes backup, battery using 12 V VRLA SMF batteries 6nos , 12V, 65AH Exide/ Quanta make with battery interconnection cables ,suitable Battery Rack for housing the batteries (Offered UPS with ISO, BIS,CE ,& RoHS markings, with local support thru company owned company operating service centres. 3 year Warranty for UPS & battery. Preferred Make:APC/Numeric/Emerson/ABB (Warranty & Onsite Support 5 Years) |
4 | Intel Core i7, 7th Generation 3.2 GHz- 8 Core or better , RAM Minimum 16 GB, HDD 1TB - (7200 RPM or faster), GPU: 4Gb or better , Operating System - Windows 10 64 bit or better OS : Windows 10 |
5 | VMS Server - Intel Xeon 8 Cores , Clock Frequency of 2.1 GHz or better, 64 GB RAM, 500 GB SSD/HDD for OS & Application , 2X1G Ethernet port OS : Ubuntu/Windows Database : MySQL or MS-SQL Storage for continous recording (50 Cameras): Approx 35 TB Usable spacesfor 30 days continous recording. (Warranty & Onsite Support 5 Years) |
6 | Refixing of Console Desk |
7 | 2 Ton Split Inverter typeAC (Warranty & Onsite Support 5 Years) |
8 | Durable, long-lasting, and washable emulsion painting of the walls and Gypsum false ceiling with appropriate lighting with theprior approval of the tendering authority for the aesthetics and ambiance fitting the decorum of the room. |
9 | Lighting |
10 | Gypsum false ceiling200 sq foot (approx) |
11 | MDF Board File rack (80 sq foot (approx) |
12 | Gypsum room partition with upvc Door - 2 Room (55 sq foot (approx)/each room) |
13 | Eectrical work for 8 console desk , PVC Surface Box including wiring from existing DB using 2 x 2.5 Sqmm + 1 x 1.5 Sqmm FRLS Cu wire through medium gauge PVC conduits withall internal connection etc |
14 | Supply, Store , Installation, Testing and Commissioning of CAT 6 U/UTP RJ45 1mtrPatch Cords shall be equipped with 8-pin modular plugs on each end. . Should comply to TIA/EIA-568-C.2 Standard, 24AWG stranded bare copper conductor, HDPE Insulation, Phosphor bronze Contact with Nickel Plated, 50 µinches gold on plug contact area,Length and color shall be available based on the site requirement - Preferred Make : Systimax/Panduit / Belden / R&M / Molex/Dlink |
15 | Supply, Store , Installation, Testing and Commissioning ofCAT 6 U/UTP RJ45 3mtr Patch Cords shall be equipped with 8-pin modular plugs on each end. . Should comply to TIA/EIA- 568-C.2 Standard, 24AWG stranded bare copper conductor, HDPE Insulation, Phosphor bronze Contact with Nickel Plated, 50 µinches gold on plug contact area Length and color shall be available based on the site requirement - Preferred Make : Systimax/Panduit / Belden / R&M / Molex/Dlink |
16 | Supply, Store, Installation, Testing and Commissioning of Category 6 UTP Single Keystone With Phase plate, shall meetUniversal labels color coded for T568A/568B, suitable for 23-26 AWG stranded and solid wire, ETL verified unshielded EIA/TIA connecting hardware, Category 6, TIA568 C.2, Contact Bracket - PC, UL 94V-2, Use insulation displacement connectors (IDC), IDC Housing - PC+ Glass Fiber, UL 94V-2, 50 µinches gold on plug contact area, Phosphor bronze with Nickel plated IDC Contact - Preferred Make : Systimax/Panduit / Belden / R&M / Molex/Dlink |
17 | Supply, Store, Installation, Testing and Commissioning of Cat-6 U/UTP patch panels Powder coated steel in 24 port configuration, should support port identification numbers on the panel, IDC: Suitable for 22-26 AWG stranded and solid wire compatible with both 110 & Krone punch down tools, Cat-6 transmission performance should be in compliance with the ANSI/TIA/EIA 568C.2 standards, 50 µinches gold on plug contact area, Phosphor bronze with nickel plated IDC Contact, RJ45 Contact Bracket PC, UL 94V-2, IDC Housing - PC+ Glass Fiber, UL 94V-2 (Preferred Make : Systimax/Panduit / Belden / R&M / Molex/Dlink |
18 | Supply and fixing of 19’’ 17 U Floor Mountrack with covered wire manager, cooling fan, AC distribution box and all other accessories. Preferred Make. Rittal/Walrack /D-Link600mm X 800mm ) Warranty 5 Years |
19 | Supply,Installation,Testing and Commissioning of Stackable Access Switch with minimum 24 x 100/1G ports, and 4 x 1/10G SFP+ ports Console port . Switching throughput - 128Gbps, Forwarding Capacity - 90 Mpps, 16K MAC Address, IPv4 and IPv6 static routing, IGMP V3,Flash Memory 64MB,IEEE802.3ad Link Aggregation with Hardware replacement warranty and ongoing software upgrades for all major and minor releases for a period of 5 years , Preferred Make. Dlink,HP,Cisco,Netgear (TEC approved products - MANDATORY TESTING & CERTIFICATION OF TELECOMMUNICATION EQUIPMENT PORTAL) |
20 | Supply and installation of WIFI access point ,Wireless access point should support Multi User 2x2 ,MIMO,internal Antennas and should be 802.11AX ,Wireless access point should support maximum wireless speeds from 400Mbps to 1.8 Gbps Should have Console Port & POE RJ-45 .Should be Wi-Fi 6 Certified Rate shall include 5 years free subscription with minor and major ongoing software upgradation Preferred Make. Dlink,HP,Cisco,Netgear (TEC approved products - MANDATORY TESTING & CERTIFICATION OF TELECOMMUNICATION EQUIPMENT PORTAL) |
21 | Supply, Store, Installation, Testing and Commissioning of Cat.6, U/UTP, AWG23, LSZH cable as per ISO/IEC 60332-3-22 Vertical Flame spread test. 100 Ohm impedance. Data transmission frequencies of up to 250 MHz. The cable and cordage shall be UTP components that do not include internal or external shields, screened components or drain wires. Should comply with the following standards: ANSI/TIA 568C.2,ISO/IEC 60754-2Acidity, ISO/IEC 61034- 2 Smoke Density. Cable should have Third party ETL verified test certificate for long distanceand short distance.(Preferred Make : Systimax/Panduit / Belden / R&M / Molex/Dlink |
22 | Supply and fixing 25mm medium gaugePVC conduits with specials confirming to the ISI standards on concrete slab/surface using suitable size fixtures spacing not exceeding 50 cm including making good the damage, colour washing etc. as required. |
23 | Supply and fixing 20mm medium gaugePVC conduits with specials confirming to the ISI standards on concrete slab/surface using suitable size fixtures spacing not exceeding 50 cm including making good the damage, colour washing etc. as required. |
24 | Supplying and fixing following size/ modules, GI / PVC Surface box along with modular base & cover plate for modulartelephone / data sockets in recess etc. as required. 1 or 2 Module (75mmX75mm) |