Maharashtra State Infrastructure Development Corporation-agecode007 has published Tender For Construction Of New Divisional Commissioner And District Collector Office And Administrative Building, Nagpur.. Submission Date for this Tender is 02-05-2024. Building Work Tenders in nagpur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42867531
Corrigendum : Tender For Construction Of New Divisional Commissioner And District Collector Office And Administrative Building, Nagpur.
Open Tender
Indian
Maharashtra
nagpur
02-05-2024

Tender Details

Construction Of New Divisional Commissioner And District Collector Office And Administrative Building, Nagpur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Mar-2024 corrigendum-1 Date 04-04-2024
2 23-Mar-2024 Extension of date Date 22-04-2024
3 04-Apr-2024 Collector_Office_Nagpur CSD Pre_Bid_Reply and Drawings Other 22-04-2024
4 12-Apr-2024 CSD Other 22-04-2024
5 15-Apr-2024 Extension of date Date 29-04-2024
6 18-Apr-2024 Corrigendum 4 Other 29-04-2024
7 27-Apr-2024 Extension of date Date 02-05-2024
8 30-Apr-2024 Corrigendum 6 CSD Other 02-05-2024
9 01-May-2024 Extension of date Date 07-05-2024

Key Value

Document Fees
INR 5900 /-
EMD
INR 21645019.0 /-
Tender Value
INR 216.45 Crore /-

BOQ Items

Name of Work : Construction of Divisional Commissioner Office, District Collector Office and Administrative Building at Nagpur.
Sl. No. Item Description
1Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
2Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
3Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.
4Providing selected hard murum filling including laying in layers of 15 to 20 cm with watering and compacting etc. complete.
5Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. 3.00m to 4.50m lift, Add 20%
64.500 m to 6.00m lift, Add 30%
76.0 m to 7.5m lift, Add 40%
8Carriage of Materials By Mechanical Transport including loading, unloading and stacking up to 5 Km
9Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Ground Floor
10Second Floor
11Third Floor
12Sixth Floor
13Seventh Floor
14Providing sacrificial shuttering for deck slab made up with galvanised Cold Rolled Cold Annealed (CRCA) steel of 310 MPA Grade with all Contractor"s material, labour, erection fixing, welding etc. (Decking Sheet ) Second Floor
15Third Floor
16Sixth Floor
17Seventh Floor
18Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
19Basement Floor
20Ground Floor
21Mezzanne Floor
22First Floor
23Second Floor
24Third Floor
25Fourth Floor
26Fiffth Floor
27Sixth Floor
28Seventh Floor
29Eight Floor
30Ninth Floor
31Tenth Floor
32Eleventh Floor
33Terrace Floor/Mumty
34Providing and laying Cast in situ/Ready Mixcement concrete in M20 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Mezzanne Floor
35First Floor
36Second Floor
37Third Floor
38Fourth Floor
39Fiffth Floor
40Sixth Floor
41Seventh Floor
42Eight Floor
43Ninth Floor
44Tenth Floor
45Eleventh Floor
46Providing and laying light weight foam concrete of density 1000kg/cum in under raised acces floors etc. all complete and as directed.
47Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
48Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
49Ground Floor
50Mezzanne Floor
51First Floor
52Second Floor
53Third Floor
54Fourth Floor
55Fiffth Floor
56Sixth Floor
57Seventh Floor
58Eight Floor
59Ninth Floor
60Tenth Floor
61Eleventh Floor
62Terrace Floor/Mumty
63Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
64Ground Floor
65Mezzanine Floor
66First Floor
67Second Floor
68Third Floor
69Fourth Floor
70Fiffth Floor
71Sixth Floor
72Seventh Floor
73Eight Floor
74Ninth Floor
75Tenth Floor
76Eleventh Floor
77Terrace Floor
78Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
79Ground Floor
80Mezzanine Floor
81First Floor
82Second Floor
83Third Floor
84Fourth Floor
85Fiffth Floor
86Sixth Floor
87Seventh Floor
88Eight Floor
89Ninth Floor
90Tenth Floor
91Eleventh Floor
92Terrace Floor
93Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
94Ground Floor
95Mezzanine Floor
96First Floor
97Second Floor
98Third Floor
99Fourth Floor
100Fiffth Floor
101Sixth Floor
102Seventh Floor
103Eight Floor
104Ninth Floor
105Tenth Floor
106Eleventh Floor
107Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Basement Floor
108Ground Floor
109Mezzanine Floor
110First Floor
111Second Floor
112Third Floor
113Fourth Floor
114Fiffth Floor
115Sixth Floor
116Seventh Floor
117Eight Floor
118Ninth Floor
119Tenth Floor
120Eleventh Floor
121Terrace Floor
122Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Basement Floor
123Ground Floor
124Mezzanine Floor
125First Floor
126Second Floor
127Third Floor
128Fourth Floor
129Fiffth Floor
130Sixth Floor
131Seventh Floor
132Eight Floor
133Ninth Floor
134Tenth Floor
135Eleventh Floor
136Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Ground Floor
137Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Basement Floor
138Ground Floor
139Mezzanine Floor
140First Floor
141Second Floor
142Third Floor
143Fourth Floor
144Fiffth Floor
145Sixth Floor
146Seventh Floor
147Eight Floor
148Ninth Floor
149Tenth Floor
150Eleventh Floor
151Terrace Floor
152Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Ground Floor
153Mezzanine Floor
154First Floor
155Second Floor
156Third Floor
157Fourth Floor
158Fiffth Floor
159Sixth Floor
160Seventh Floor
161Eight Floor
162Ninth Floor
163Tenth Floor
164Eleventh Floor
165Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Basement Floor
166Ground Floor
167Mezzanine Floor
168First Floor
169Second Floor
170Third Floor
171Fourth Floor
172Fiffth Floor
173Sixth Floor
174Seventh Floor
175Eight Floor
176Ninth Floor
177Tenth Floor
178Eleventh Floor
179Terrace Floor
180Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Basement Floor
181Ground Floor
182Mezzanine Floor
183First Floor
184Second Floor
185Third Floor
186Fourth Floor
187Fiffth Floor
188Sixth Floor
189Seventh Floor
190Eight Floor
191Ninth Floor
192Tenth Floor
193Eleventh Floor
194Terrace Floor
195Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Basement Floor
196Ground Floor
197Mezzanine Floor
198First Floor
199Second Floor
200Third Floor
201Fourth Floor
202Fiffth Floor
203Sixth Floor
204Seventh Floor
205Eight Floor
206Ninth Floor
207Tenth Floor
208Eleventh Floor
209Terrace Floor
210Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Basement Floor
211Ground Floor
212Mezzanine Floor
213First Floor
214Second Floor
215Third Floor
216Fourth Floor
217Fiffth Floor
218Sixth Floor
219Seventh Floor
220Eight Floor
221Ninth Floor
222Tenth Floor
223Eleventh Floor
224Terrace Floor
225Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Basement Floor
226Ground Floor
227Mezzanine Floor
228First Floor
229Second Floor
230Third Floor
231Fourth Floor
232Fiffth Floor
233Sixth Floor
234Seventh Floor
235Eight Floor
236Ninth Floor
237Tenth Floor
238Eleventh Floor
239Terrace Floor
240Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Ground Floor
241Mezzanine Floor
242First Floor
243Second Floor
244Third Floor
245Fourth Floor
246Fiffth Floor
247Sixth Floor
248Seventh Floor
249Eight Floor
250Ninth Floor
251Tenth Floor
252Eleventh Floor
253Terrace Floor
254Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Basement Floor
255Ground Floor
256Mezzanine Floor
257First Floor
258Second Floor
259Third Floor
260Fourth Floor
261Fiffth Floor
262Sixth Floor
263Seventh Floor
264Eight Floor
265Ninth Floor
266Tenth Floor
267Eleventh Floor
268Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing,cleaning complete. b) Granite Mezzanine Floor
269First Floor
270Second Floor
271Third Floor
272Fourth Floor
273Fiffth Floor
274Sixth Floor
275Seventh Floor
276Eight Floor
277Ninth Floor
278Tenth Floor
279Eleventh Floor
280Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Basement Floor
281Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Basement Floor
282Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 60 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete
283Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Basement Floor
284Ground Floor
285Mezzanine Floor
286First Floor
287Second Floor
288Third Floor
289Fourth Floor
290Fiffth Floor
291Sixth Floor
292Seventh Floor
293Eight Floor
294Ninth Floor
295Tenth Floor
296Eleventh Floor
297Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Ground Floor
298Mezzanine Floor
299First Floor
300Second Floor
301Third Floor
302Fourth Floor
303Fiffth Floor
304Sixth Floor
305Seventh Floor
306Eight Floor
307Ninth Floor
308Tenth Floor
309Eleventh Floor
310Terrace Floor
311Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish Mezzanine Floor
312First Floor
313Second Floor
314Third Floor
315Fourth Floor
316Fiffth Floor
317Sixth Floor
318Seventh Floor
319Eight Floor
320Ninth Floor
321Tenth Floor
322Eleventh Floor
323Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor
324Mezzanine Floor
325First Floor
326Second Floor
327Third Floor
328Fourth Floor
329Fiffth Floor
330Sixth Floor
331Seventh Floor
332Eight Floor
333Ninth Floor
334Tenth Floor
335Eleventh Floor
336Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor
337Mezzanine Floor
338First Floor
339Second Floor
340Third Floor
341Fourth Floor
342Fiffth Floor
343Sixth Floor
344Seventh Floor
345Eight Floor
346Ninth Floor
347Tenth Floor
348Eleventh Floor
349Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Basement Floor
350Mezzanine Floor
351First Floor
352Second Floor
353Third Floor
354Fourth Floor
355Fiffth Floor
356Sixth Floor
357Seventh Floor
358Eight Floor
359Ninth Floor
360Tenth Floor
361Eleventh Floor
362Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. (To be secured to the backin and the sides by means of cramps and pins whick shall be paid for separately) Basement Floor
363Ground Floor
364Mezzanine Floor
365First Floor
366Second Floor
367Third Floor
368Fourth Floor
369Fiffth Floor
370Sixth Floor
371Seventh Floor
372Eight Floor
373Ninth Floor
374Tenth Floor
375Eleventh Floor
376Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
377Providing and laying 20mm thick mirror polished Granite Stone in Risers of steps of approved colour, size and pattern, (sample of granite stone shall be approved by Engineer-in-charge) over 12 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of granite stone complete as per specifications and relevant drawings.
378Extra for Red/ Raw Silk/ Tan Brown/ Jet Black granite
379Providing and laying polished granite slab of approved colour, origin and shade, 18mm thick laid in skirting on 20mm (average) thick cement mortar 1:4 (1 cement: 4 coarse sand), sprinkled with white cement and jointed with white cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. Rates include coordination with other agencies for cutouts, holes and finishing of the same. 600mm x 100mm sized polished granite slabs
380Providing and laying 30mm thick Honed Grey Granite Stone flooring in treads and landings (including bull nosing, rounding the nose and making groove) of steps of approved colour, size and pattern, (sample of granite stone shall be approved by Engineer-in-charge) over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 core sand) laid and jointed with neat cement slurry mixed with pigment to match the shade of granite stone complete as per specifications and architectural drawings. Allow for cutting & finishing for handrails fixing as per design.
381Extra for Red/Raw silk/Tan Brown/Jet Black granite
382Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Ground Floor
383Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scrapping if necessary including scaffolding etc. complete. Basement Floor
384Ground Floor
385Mezzanine Floor
386First Floor
387Second Floor
388Third Floor
389Fourth Floor
390Fiffth Floor
391Sixth Floor
392Seventh Floor
393Eight Floor
394Ninth Floor
395Tenth Floor
396Eleventh Floor
397Terrace Floor
398Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. Ground Floor
399Terrace Floor
400Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. Ground Floor
401Mezzanine Floor
402First Floor
403Second Floor
404Third Floor
405Fourth Floor
406Fiffth Floor
407Sixth Floor
408Seventh Floor
409Eight Floor
410Ninth Floor
411Tenth Floor
412Eleventh Floor
413Terrace Floor
414Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. Basement Floor
415Ground Floor
416Mezzanine Floor
417First Floor
418Second Floor
419Third Floor
420Fourth Floor
421Fiffth Floor
422Sixth Floor
423Seventh Floor
424Eight Floor
425Ninth Floor
426Tenth Floor
427Eleventh Floor
428Terrace Floor
429Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins) Mezzanine Floor
430First Floor
431Second Floor
432Third Floor
433Fourth Floor
434Fiffth Floor
435Sixth Floor
436Seventh Floor
437Eight Floor
438Ninth Floor
439Tenth Floor
440Eleventh Floor
441Providing and Fixing Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7 Kilograms/M2 with a minimum pull out strength of 100 Kilograms. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Mezzanine Floor
442Second Floor
443Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Second Floor
444Third Floor
445Sixth Floor
446Seventh Floor
447Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece.
448Providing & Fixing in position, Acoustical Panelling made from 12mm thick Agro wood strips of 50, 75 7 100 mm width on 50 x 50 mm Sal-wood frame of 600 x 600 c to c having supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with approved coloured fabric on strips side & chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / Melamine Polish & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete Ground Floor
449Mezzanine Floor
450First Floor
451Second Floor
452Third Floor
453Sixth Floor
454Seventh Floor
455Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 16 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval The 16mm thick panels shall be used for a roofing height of upto 15 mtrs.
456Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Ground Floor
457Mezzanine Floor
458First Floor
459Second Floor
460Third Floor
461Fourth Floor
462Fiffth Floor
463Sixth Floor
464Seventh Floor
465Eight Floor
466Ninth Floor
467Tenth Floor
468Eleventh Floor
469Solid Core Flush door Single leaf :Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter Ground Floor
470Mezzanine Floor
471First Floor
472Second Floor
473Third Floor
474Fourth Floor
475Fiffth Floor
476Sixth Floor
477Seventh Floor
478Eight Floor
479Ninth Floor
480Tenth Floor
481Eleventh Floor
482Panic Bar: (For 2 Hr fire Rated single Panic bar) : Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/hollow metal/ Al framed door,with maximum operating force 8Kilogram for unlocking easily & outwardly during emergency,complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at "FIRE EXIT"only under location specific instruction of Eingineer-in -Charge.) Basement Floor
483Ground Floor
484Mezzanine Floor
485First Floor
486Second Floor
487Third Floor
488Fourth Floor
489Fiffth Floor
490Sixth Floor
491Seventh Floor
492Eight Floor
493Ninth Floor
494Tenth Floor
495Eleventh Floor
496Terrace Floor
497Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick float glass etc. complete. a) With colour anodizing Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered. First Floor
498Second Floor
499Third Floor
500Fourth Floor
501Fiffth Floor
502Sixth Floor
503Seventh Floor
504Eight Floor
505Ninth Floor
506Tenth Floor
507Eleventh Floor
508Fire Door (Staircase and exit pathways applications) : Providing and fixing of Hollow metal fire rated doors as per IS 3614 :2021 for stability,integrity and insulation criteria for first 30minutes. Pressed Galvanized steel confirming to IS 277 with the following specification. Fire door shall have tested at CBRI or TBW for as per IS/ ISO 3008-1 for 2 hrs with insulations. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent. Door frame shall be Single rebate grooved step design frame profile of size 125 x 75mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with fire rated PUF or cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf shall be step design 60mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be mineral wool of minimum desity of 120kg/m3. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with lock seam. For pair of doors integrated astragals will be provided as required. Vision lite wherever applicable should be provided as per manufacturers recommendation with a beeding and screws from inside. The glass should be minimum 5mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished to “PURE POLYSTER POWDER COATING” for minimum 50 microns (on the visible surface of the Shutter and Frame) of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test
509Fire Door (other utility area and non egress like service shafts applications) : Providing and fixing of Hollow metal fire rated doors as per IS 3614 2021 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2 hrs with vision panel. Test certificates should be available for vision lites /panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent. Door frame shall be Single rebate grooved frame profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with fire rated PUF or cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf shall be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with lock seam. For pair of doors integrated astragals will be provided as required. Vision lite wherever applicable should be provided as per manufacturers recommendation with a beeding and screws from inside. The glass should be 5/6mm clear borosilicate fire rated glass of relavant rating of the door. All doors and frames shall be finished to “PURE POLYSTER POWDER COATING” for minimum 50 microns (on the visible surface of the Shutter and Frame) of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test
510Clear Vision panel of 200mm*300mm per leaf with fire rating
511Heavy Duty Door closer with EN2-4
512Eurofile Mortice lock 240 with double pin cylinder k x k and SS handles
513Concealed flush bolts (300mm)
514SS ball bearing butt hinges of 100x75x3mm
515SS handles Dorma or equivalent make for double leaf door
516Smoke seal for fire doors
517Intumecent seal for fire doors
518Fire rated single point Panic bar on staircase single leaf doors
519Fire rated double point Panic bar on staircase double leaf doors
520External trim for fire doors including half cylinders
521Providing and fixing multipurpose GI door with shutter fabricated from18 gauge thick galvanised steel sheets press formed to provide a 46mm thick fully flushed double skin door with lock seam joints at stile edge and infill honeycomb kraft core. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with lock seam. For pair of doors integrated astragals will be provided as required. Vision lite wherever applicable should be provided as per manufacturers recommendation.Door frames 125x55mm groved profile with single rebated made of 16 gauge galvanised steel. All doors and frames shall be finished to “PURE POLYSTER POWDER COATING” for minimum 50 microns (on the visible surface of the Shutter and Frame) of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray teste. Once frame installed should be grouted with PUF or cement & sand slurry necessary for fire doors on the clear masonry opening.
522Proviidng and fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complete with SS Screws of approved make or equivalent etc all complete as per drawing and as directed by the Engineer in Charg.
523Proviidng and fixing of of door closers of EN2-4 with std arm of approved make or equivalent etc all complete as per drawing and as directed by the Engineer in Charg.
524Eurofile Mortice lock -240 with double pin cylinder k x k and ss handles
525Concealed flush bolts (300mm)
526Proviidng and fixing of Back To Back Pull Handle for the & Metal Door with Back to back fixing . 304 Grade SS size 300 mm of approved make or equivalent etc all complete as per drawing and as directed by the Engineer in Charg.
527Providing and fixing in position frameless glass partition walls made out of 12mm thick toughened clear float glass held in position by wall connecting profile with patch fittings and necessary hardware etc all complete as per direciton of Engineer in Charge.
528Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor springtype fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately)
529Providing & fixing Toilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water,chemical,scratch, impact and anti bacterial resistant 12mm thick solid compact laminate panels tested in approved laboratory. Finish of the compact laminate should be Suede, Raw silk model includes doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian standard) and as per fire retardant BS-476/97 standard. This also includes providing and fixing in position necessary hardware made out of stainless steel (Grade 304) as per manufacturers specifications & Architects instructions like (1)Door knob(2)Gravity hinges(3)Thumb turn lockset with occupancy indicators(4)Coat hooks with Door stopper(5)U-channels(6)Adjustable foot/pedestal(7)Top rail with corner connector(8) Rubber noise deafening tape(9)Screws & wall plugs. All screws will of 304 Grade in stainless steel with satin finish. All pilasters are supported by stainless steel bottom cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height up to 150mm. the top fitting should consist of SS round top rail which will get fixed with pilasters, with SS panel tube holder, SS corner bend (connected with top rail) will be used on the corner of cubicle in absence of brick wall, SS wall fixing is used only on the wall which will hold the SS top rail. Toilet Cubicle with standard dimension of 1980mm Height x 1000mm width x 1550mm Depth, which includes up to 600mm door size width)
530Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground Floor
531Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts, etc. of the required size on the top of the floor of the side of waiste slab with suitable arrangement as per approval of engineer in charge (for payment purpose, only the weight of the stainless steel members shall be considered excluding fixing accessories such as nut bolts, fasteners etc.). 50mm dia. pipe, 1.5mm thickness and weight 1.92Kilogram/ r. metre Basement Floor
532Ground Floor
533Mezzanine Floor
534First Floor
535Second Floor
536Third Floor
537Fourth Floor
538Fiffth Floor
539Sixth Floor
540Seventh Floor
541Eight Floor
542Ninth Floor
543Tenth Floor
544Eleventh Floor
545Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
546Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material
547Wet Mix Macadam -- Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver.
548Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement with max 20% fly Ash ( Fly-ash upto 20% by weight of Cement) over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a Tilting type Concrete Mixer as per approved mix design, admixtures, spreading, laying compacting and finished in a continuous operation without paver machine, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
549Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
550Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
551BITUMINOUS MACADAM:--Providing and laying bituminous macadam using crushed aggregate of Grading 1, premixed with bituminous binder, transported at site with VTS, laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 80/100 mm compacted thickness with drum mix type hot mix plant with SCADA having complying essential features of Hot mix plant as per IRC-27 2009 specified conditions and attachments such as electronic load sensor based belt conveyers,automatic synchronization of bitumen and aggregate fedder,built in dust controller system and PLC for Drum Mix plant ,Sensor paver,and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen 3.30% of specified grade (VG-30 bulk bitumen rates are considered to arrive at rates)
552DENSE BITUMINOUS MACADAM:--Providing and laying dense bituminous macadam using crushed aggregate of grading 1, premixed with bituminous binder Bitumen of specified grade,@ 4.50 % by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface , finished to the required grade ,level, alignment,and rolling to achieve the desired density for 76/100 mm compacted thickness with drum mix type hot mix plant with SCADA having complying essential features of Hot mix plant as per IRC-27-2009 specified conditions and attachments such as electronic load sensor based belt conveyers, automatic synchronization of bitumen and aggregate fedder,built in dust controller system and PLC for Drum Mix plant ,Sensor paver, and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen VG-30 grade with stone dust filler (VG-30 bulk bitumen rates are considered to arrive at rates)
553BITUMINOUS CONCRETE:--Providing and laying bituminous concrete using crushed aggregate of grading 1, premixed with bituminous binder @5.40% by weight of total mix and filler, transported at site with VTS, laid over a previously prepared surface, finished to the required grade ,level, alignment, and rolling to achieve the desired density for 50mm compacted thickness with drum mix plant with SCADA, Sensor paver and Vibratory roller excluding prime/Tack coat etc. complete --Bitumen of specified grade with stone dust filler. (VG-30 bulk bitumen rates are considered to arrive at rates)
554Providing and fixing kerbstone with led lighting system as per following specifications: dimensions with vertical mounting legs with 10mm horizontal square shape mild steel reinforcements. Illuminated kerb stone having visible dimensions :-500mm x 150mm x 150mm.(as per irc - 86-1983 ) 80mm legs having ms reinforcements shal be embedded in bt/concrete road surface.the kerb stone should have kerb angle of 45 degree, with rubber plugs at both ends of the kerbstones (2 nos)having load carrying capacity - vertical : 1465kg, horizontal : 2349 (certified by govt. Recoganized bodies)having thermal stability -: -40 to +120 degree celcius (certified by govt. Recoganized bodies. Illuminated kerb stones including : ingrace protection and connector rating ip67, electrical wire -(as per is: 694), led strip (as per lm:80) standard. Including for electrical fixing -frp junction box consisting of - 10amp. Switch module power supply(smps)having input voltage - 230v ac, output voltage 36v dc, 2 pole mcb. Illuminated kerb stones having warranty for 3 years. illuminated kerbstone shall be fixed into cast-in-situ cement concrete of m20 grade at base, back filling and grooves, including dismantling, fixing, removal of dismantled material and cleaning etc. Complete. The colour of kerb stone shall be provided as directed by engineer in charge.
555Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern.
556Cutting down trees including trunks and branches with girths above 30cm to 60cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
557Cutting down trees including trunks and branches with girths above 60cm to 90cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
558Cutting down trees including trunks and branches with girths above 90cm to 180cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
559Cutting down trees including trunks and branches with girths above 180cm to 270cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
560Cutting down trees including trunks and branches with girths above 270cm to 450cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
561Cutting down trees including trunks and branches with girths above 450cm and stacking the materials neatly with all lifts and lead of 1000m. as directed and earth filling in the depression/pit if any.
562Providing and fixing cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
563Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing. 30 mm thick
564Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
565Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payableseparately.The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
566Providing, assembling and supplying vision glass panels (IGUs)comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
567Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in- Charge.
568Aluminium screen facade system : Supply and fixing of screen panel cladding system, of various sizes, the maximum length of panels shall be 4000 mm X maximum width as per design, shall comply as per the architectural and structural design requirement. The panels are manufactured from high corrosion resistant aluminum alloy AA 3105 and thickness of panel shall be 5.0 mm and shall be firmly secured to the secondary to the secondary rigid steel structure.The single skin screen facade shall meet design requirement and should be enable to add features, accents and diversity of appearance to solid or perforated facade applications to create visual impressions. The maximum open perforated area of the panel shall be up to 20 %. The random perforation shall be done on CAD/CAM auto index turret machine using CNC technology, according to the perforation design of the panels and to ensure dimensional accuracy of perforation. After perforation, the aluminum coil shall be levelled on marini levelling machine to ensure the panel flatness. The Panels shall be bend on all four sides and shall have extended flanges to accommodate the clamps. The panel bending shall be preferably done on RAS folding machine or Amada or Gaspirini press brake machine to ensure proper bending quality.The panels of required length and height to be fixed to rigid steel sub structure suitable for the screen façade (Sub-Structure to be provided by the Main Contractor and shall be paid seperately in an appropriate item) by means of screen panel guide & adjustable clamps in extruded aluminum to ensure proper alignment and to be coated in approved powder coated finish. The panel fixing type shall be side fixing, the customised extrusion clamps shall be fixed to the panel at an appropriate center to center distance based on the structural design calculations by considering the relevant wind load and a dead load combination. The installation shall be carried out as per the manufacturer recommendation. The panels shall be coated on visible side with exterior architectural super durable polyester powder coated for minimum 60 microns in approved RAL color and backside with a primer coat of the same color. The panels are powder coated with Qualicoat certified powder only. Aluminium panels shall be pre-treated with eco-friendly Silan based nano technology pre-treatment. The latest technology based powder coating process and electrostatically powder coated with automatic corona system and cured with a combination of Infrared & hot air circulated oven in a certified plant. Manufacturer should have in house testing lab and powder coating line with Nano technology & Catalytic Converter Oven. The Exterior grade powder shall confirm with the performance requirements of AAMA 2603.02 & Qualicoat Class 1 specifications. The coating thickness shall be average 60 microns and Salt Spray resistance complaint for 1500 hrs exposure in SST Cabinet with Minimum blister rating 8 as per ASTM B-117, AAMA2603.02, 6.7.2,ASTM D1654 and Weather resistance of 12 Months Florida Exposure as per AAMA2603.02, 6.8. Manufacturer Pre-Qualification Criteria : Make in India: The manufacturer should have manufacturing plant in India to the promote make in India products as per the latest directives of Government of India.Experience: The manufacturer should have minimum experience of 10 years in similar product manufacturing application in India.Quality Management System: The company should have own Manufacturing Plant with QC Laboratory.ISO Certification - ISO 9001: 2015 Quality Management System Certification shall be mandatory.Sustainability: The manufacturer should be able to submit "IGBC GreenPro Certificate" for the product proposed for green building certification.Fire Rating : Product should be noncombustible and should not propagate the fire. Product shall comply for BS 476 Part 3 , Part 4 , Part 6 & 7Seismic Resistance: The product shall meet the Seismic Standard IS1893 -2002, Zone 5 (Five) tested by a specialized and reputed Indian testing Institution.Advanced Technology: Manufacturer should have fully automatic plant with leveling machine along with auto index machine to ensure flatness and perforation dimensional accuracy of the panels.Capacity : Manufacturer should have the capacity to supply the huge quantity of this scale in time bound manner.Manufacturers: Hunter Douglas India Pvt. Ltd. / COLT PRODUCTS AND SYSTEMS/ SCHUCO
569LUXALON® Aluminium, Un-perforated, 300C Ceiling with fixed and demountable Torsion Spring. System:Supply of Luxalon® 300C un-perforated Aluminium panel ceiling manufactured by M/s. Hunter Douglas of any solid colour consisting of panel 300mm wide x 30 mm deep x 0.7mm thick with bevel edge, panel length up to 6 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. The Panels shall about each other with a narrow V grove. Panel shall be clipped to a baked enamelled aluminium panel carrier of 41.5mm wide x 62mm deep x 0.95mm thick in standard length of 5 mtr made of doubled baked black enamelled aluminium alloy AA 5050 (Al. Mg) with cut outs to hold the panels in a module of 300mm closed at a distance 2 mtr. Panel carrier shall be suspended by means of G.I. suspension rod 4mm diameter and a Galvanised suspension spring clip at a distance of 1.7 mtr c/c. Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification compliant with in house testing facility and should have their own manufacturing plant in India from last five years. Seismic Testing - Metal ceiling Tested for Seismic Zone V compliance as per IS 1893 part 1-2016 Coating - In-house Powder Coating line with Nano technology & catalytic converter in India: For superior powder coating finishes with automatic electrostatic robotic coating technology for uniform coating and Five (5) times cleaning process with Nano Technology for better adhesion and corrosion protection. Mode of measurement : Measurements shall be wall to wall without deductions for lights, diffusers, columns etc.
570U Baffle open ceiling with fixed and demountable Torsion Spring.Supply of torsion spring U-Baffle Ceiling System, comprising of baffle width of 50mm and height of 100mm manufactured out of 0.6mm thick Coil Coated Aluminium of alloy AA 3105 at a module of 175 mm. The baffle shall be manufactured on high speed, high precision roll forming machine with ARKU SIX Hi configuration roller levelling process to ensure the flatness and to avoid the failure of metal at corners which may occur normally on press brake machine. The coil is coated on a continuous paint line double baked and shall be stove enamelled in a continuous coil coating process of the approved colour on the exposed side and the reverse side with polyester primer. The U Baffle ceiling panels shall be mounted on coil coated customised Hat type Aluminium carrier of size 60mm * 30mm * 0.9mm thk. The customised carrier shall be suitable for both torsion spring based & standard fixed Baffle panels. The carrier shall be suspended with M6 Threaded rod hangers spaced at 1200mm c/c. Maximum upto 20% of the total ceiling area, based on client requirement, shall be demountable torsion spring-based panels. The length of the panel shall be upto 2400mm. Suspension System: As per manufacturer standard it is recommend to have minimum gap of 250mm between plenum and its baffle top surface height for easy engagement of spring. The baffle ceiling system should meet the required standards for Green Pro certification and should qualify as green product as per CII green products and services council. The manufacturer should be ISO 9001:2015 Quality Management System Certification compliant with in house testing facility and should have their own manufacturing plant in India. Main Runners: 39 mm deep, inverted “Tee” sections, 3.6m long, with factory punched flanges to receive Torsion spring assembly. Main Tee on center spacing to match panel length.Cross Runners: 39 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced spacing 1200mm on center maximum. Suspension System: As per manufacturer standard it is recommend to have minimum gap of 250mm between plenum and its baffle top surface height for easy engagement of spring. CEILING FINISH ABOVE U BAFFLE CEILING: Ceiling area above U Baffle to be painted in black colour before fixing this system (Not in the scope of Hunter Douglas).Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. Green-pro certification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2015 Quality Management System Certification. Roll Forming - Manufacturers should have Roll forming Machine with six roller leveling process ensures flatness of panels.Seismic Testing - Metal ceiling Tested for Seismic Zone V compliance as per IS 1893 part 1-2016Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. Approved Make : Hunter Douglas, SAS, Gordan
571Providing and fixing torsion spring Plank Ceiling System Hunter Douglas make of approved finish comprising of Plank of 600mm wide and 1200mm long manufactured out of 0.9mm thick Aluminium Alloy 3105 perforated 1.5mm dia With 22% open area. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Plank will be manufactured on advanced CAD/CAM equipment that includes several levelling stages in the manufacturing process. Torsion Spring panel with two side legs die formed and two end legs die formed and punched to receive torsion springs (min two springs each end or side) for secure engagement into Tee Grid main runners which are factory punched to receive torsion springs. Planks will be square edged. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Plank shall be Polyester powder coated in desired colour. All complete as per drawings, specification and direction of the Engineer in Charge. All Ceiling products shall adhere to Green Pro Certification. The Metal ceiling is Tested for Seismic Zone V compliance as per IS 1893 part 1-2016”Main Runners: 24mm deep, inverted “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on centre spacing to match panel length.Cross Runners: 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced spacing 1200mm on centre maximum. Suspension System: As per manufacturer standard considering type of plenum and its height.Paint finish – The panels will be pre treated in latest nano technology process and electro statically powder coated with automatic Carona system and cured with gas catalytic technology.Acoustic Felt (Optional): Non-woven felt made of glass-reinforced fibre glued over the perforation for sound absorption. NRC- 0.7Approved Make : Hunter Douglas, SAS, Gordan
572Dismantling
573WATERPROOFING FOR RAFT Supplying and installing 1.5 mm composite thick fully bonded weldable HDPE membrane conforming to IS 16471:2017 requirements of UG waterproofing structures, requirements to provide Type A fully bonded protection of UG waterproofing structures. The membrane shall exhibit 25 years of service life tested and complied in accordance with EN 13251:2016 durability certification. The membrane should be minimum 2.4 m wide comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weatherproof protective layer with lap Joint Strength at overlaps >15000 N/m ASTM D 6392:2012. The membrane shall have minimum of 100 mm side and end laps which shall be thermofused with leister machines at all the joints for assuring watertightness and achieving monolithic membrane. End laps and side laps should be a minimum of 100 mm with the weld size of minimum 60 mm in case of a single weld system. In case of a double weld system, comprising of two parallel welds of 20 mm wide each with a 20 mm air channel gap in between the two weld lines.The size of the membrane should not be less than 2.4 Mtr. x 20 Mtr. to minimize the joints. This membrane shall be continued over the vertical surface but terminated minimum 100mm below the top edge of the raft slab/footings and fixed, etc all complete as per specifications & instructions of Engineer in Charge.
574Providing and fixing Swellable water stop 20 X 10mm at construction joint at junction of raft and retaining wall. Providing and applying water swellable bar at starter & all construction joints, of size of minimum 20mm X 5mm, it shall have resistance to deterioration from salt water, volumetric expansion > 200%, Elongation > 400%, Shore A Hardness > 35, Tensile strength > 2 Mpa, Temperature resistance : (-) 20 to +75 deg C, Water head resistance > 50 m. It shall be fixed to the concrete using a gun grade hydrophilic adhesive / or mechanically fixed by binding wire with steel reinforcement, as recommended by manufacturer. Later post construction, groove cutting of the construction joints 25mm X 25mm size internally / externally, cleaning with compressed air and thereafter filling with Polymer modified cementitious mortar, all as per manufacturers recommendations etc all complete as per specifications & instructions of Engineer in Charge.
575WATERPROOFING FOR RETAINING WALL Providing and laying 1.5 mm thick SBS based self-adhesive waterproofing membrane topped with HDPE cross laminated valeron film with the following technical properties-Softening point of 105 (oC) as per ASTM D36 ,Tensile Strength (L/T)- 3.5 N/sq.mm as per ASTM D412,Elongation (L/T) L- 180 % ,T -180% as per ASTM D 412, Puncture Resistance- 200 N as per ASTM E 154, Hydrostatic pressure > 60 m (6BAR) No leakage as per DIN 1048, including cleaning the surface and removal of flaky materials ,grouting the porous areas with cementitious grout, proper coving(50 mmx 50mm)at sharp edges of concrete and priming the surface with cold applied bituminous primer @150 gm /sq.mtr. The SBS membrane should be sealed properly at joints and maintaining 75 mm overlap between the membrane selvedge & 100 mm overlap on the end joints of the membrane over the slab etc. complete . Termination: The membrane shall be terminated at 300 mm above the Finished floor level by applying aluminum strip flashing with fasteners at the top and sealing the joints with PU sealant. etc all complete as per specifications & instructions of Engineer in Charge.
576Providing & Fixing of protection board 8MM HDPE Dimple board spot bonded on retaining wall before backfilling etc all complete as per specifications & instructions of Engineer in Charge. .
577Providing aluminum flashing, wherever required for termination of self dhesive membranes at all locations. Item shall include rates for membrane termination on the Vertical retaining wall at height 300mm above the ground level for termination of the membrane and finally sealing the strip using Polysulphide sealant etc all complete as per specifications & instructions of Engineer in Charge.
578Base preparation of cleaning, brushing and removal of any loose/flacky materials, in case of pot holes/cracks, the same shall be repaired with polymer modified cement mortar using SBR Latex. Supplying and applying 10 mm thick, two components instant setting spray applied polyurethane Waterproofing system,polymeric closed cell PU Foam with a core density of 45-50kg/cu.mt as per ASTM D1622. The cured foam should behaving closed cell apparent of 96%-98% by volume as perASTM D-2856, thermal conductivity of 0.029W/MK as per ASTM C-518/91 and having fire resistance properties conforming to class B2 as per DIN4102 as per the manufacturer"s recommendations. Supplying and apply single component cold applied polyurethane elastomeric coating having solid content 90% as per ASTM C836,elongation at break > 400% ASTM D-612, hardness 75 shoreA, as per ASTM D2240 @1 kg/m2, brush applied waterproofing coating, on top of cured PU foam systemSpreading120 gsm Geotextile (non woven polyester). Supplying and applying slope making and protection to the waterproofing treatment with 75mm avg. thick M20 grade screed (Screed should be paid in separate in DSR item no 22.14.1 (S.No. 40) All around on the roof, at the parapet wall junction, an angular fillet of 50 mm X 50 mm shall be made in cement-sand mortar in 1:3 proportion. The concrete shall be exposed by cutting grooves of size 6mm(W) x35mm(D) by saw cutting into panels of size 3 x 4mtrs,the grooves formed by exposing the concrete shall be filled with polysulphide sealant.
579Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means. Removal of all surface imperfections, protrusions, loose concrete & filling of cracks using SBR latex modified Mortar in the ratio Cement: Sand (1:4) and 5% of -SBR latex by weight of cement. Applying two coats of 2 component polymer modified cementitious coating of tensile strength of 1.0 N/Sq.mm as per ASTM D 412,elongation of 120% as per ASTM D 412 ,crack bridging of 2mm as per ASTM C836,Shore A hardness of 60 as per ASTM D2240 & resisting 5 bars hydrostatic pressure as per DIN 1048 applied@ 2kg/sq.mtr all over the the entire horizontal and extended up to 300mm above the FFL on the vertical surface as per manufacturer"s recommendation. Finally sprinkling sand over the third coat for better adhesion with plaster. The interval between each coat of coating application is 6-8 hrs.The waterproofing system should be applied directly by the manufacturer with 10 years of complete system warranty against leakage. including Providing and laying 120gsm Geotextile over the entire horizontal area maintaining proper overlaps. Toilet Sunken Portion Horizontal protection: Supplying and applying slope making protection with 40 mm avg thick M20 screed (Screed to be paid seprately in Screed Items) Vertical Protection: Providing and applying 15 mm thick with CM 1:4 for wall plastering admixed with integral waterproofing compound admixed @ 0.2litre/bag of cement as per manufacturer"s specifications including curing etc. (Plaster to be paid seprately in Plaster Items)
580Providing and applying two component polymer based cementitious waterproofing system in following sequence; Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical means. Removal of all surface imperfections, protrusions,loose concrete & filling of cracks using SBR latex Modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement. Providing & grouting at construction joints cementitious grout into each nozzles( 1 mtr c/c) at regular intervals as per the requirements. Providing and making fillets at the junction of the walls and the slabs using cement mortar of 1:4 mix admixed with 5 % of SBR latex by weight of cement. Applying 3 coats of 2 component, prepacked,polymer modified cementitious coating of tensile strength of 1.0 N/Sq.mm as per ASTM D 412,elongation of 120% as per ASTM D 412 ,crack bridging of 2mm as per ASTM C836,applied @ 3kg/sq.mtr all over the slab including the angular fillets and extendable over the vertical walls .Finally sprinkling sand over the third coat for better adhesion with plaster. The interval between each coat of coating application is 6-8 hrs. Providing & laying a protection layer of 20 mm thick cement mortar (1 cement :4 Coarse sand) admixed with integral waterproofing compound as per IS 2645 Providing & applying two coats of antibacterial antifungal food grade epoxy coating at a consumption of 3 Sq.mtr/kg as per CFTRI 21 CFR 175 - 300 of US - FDA , Water absorption nil as per ASTMC 870:90, adhesion strength of 2.5 N/mm2 as per ASTM D4541:02 applied with an interval of 6-8 hrs between each coat over the cured plastered surface as per manufacturer’s instruction. (UGWT & OHT )
581Terrace Garden Polyurethane based waterproofing system for podium and landscape decks.Base preparation of cleaning, brushing and removal of any loose/flacky materials, in case of pot holes/cracks, the same shall be repaired with polymer modified cement mortar using SBR latex. Applying liquid applied, pure polyurethane based, single component, low VOC, elastomeric, seamless, waterproof membrane, applied in 2 coats over one coat of primer at a total consumption of min. 2.5 Kg./ Sq.Mt. to achieve a DFT of 1.5 mm &thereafter providing & laying 120 GSM polyester geotextile layer. Further laying protective concrete screed of average 75 mm using M20 grade concrete with minimum thickness of 40 mm at the rain water outlet and a slope of 1:120, making wattas at the junctions of horizontal and vertical surfaces to a float finish, well compacted, curing for 7 days etc. complete.(Protective concrete screed shall be paid in DSR item no 22.14.1 (S.No. 40)
582Supply and installation of Rolled Matrix Soil Filter cum surface drainage System as per manufacturers specifications. Fixing of 10mm thick polypropylene geotextile laminated dimpled board, of compressive strength not less than 400kN/m2. This geotextile fabric composite allows passage of moisture through fabric while preventing fine soil from entering to drainage channel.bonded to a high strength polypropylene geotextile fabric This geotetile fabric composite allows passage of moisture through fabric while preventing fine soil from entering to drainage channel.
583Horticulture Work Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
584Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
585Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : a) Screened through sieve of I.S. designation 4.75 mm
586Rough dressing the trenched ground including breaking clods
587Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
588Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
589Flooding the ground with water including making kiaries and dismantling the same.
590Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge
591Internal & External Plumbing Work Providing and fixing wall hung white wash basin of size 550 x 400 x 195 mm with pillar cock having flow rate up to 6.0 Litr/Minute,C.P.Angular stop cock long thread of Jaquar/Cera/Hindware /Perryware or equivalent make, including SS bottal trap of approved make etc complete as directed by Engineer in charge.( Make shall conform to manufacturer"s Green product and shall got approved from the Engineer In Charge
592Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer"s Green product and shall got approved from the Engineer In Charge.)
593Providing and fixing white glazed urinal with Pressmatic auto closing valve having flow rate upto4.0Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make with P.V.C. waste pipe with fitting arrangement etc. complete as directed by Engineerin charge. (Make shall conform to manufacturer"s Green product and shall got approved from the Engineer In Charge.)
594Providing and fixing 10 cm PVC nahani trap with grating etc. complete.
595C.P.Handshower (health faucet) 1m.PVC tube with wall hook jaquar make (Cat. No. ALD 563 )
596Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete.
597Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
598Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete
599Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complet
600Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
601Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
602Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
603Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
604Providing and fixing on walls/ ceiling/ floor 65 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
605Providing and fixing on walls/ ceiling/ floor 80mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
606Providing ,laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
607Providing and fixing 75mm dia stabiliser pipe /P.V.C. soilvent /wastepipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent,clamps etc. complete
608Providing and fixing 100mm dia stabiliser pipe /P.V.C. soilvent /waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
609P.V.C.pipe 160mm dia.Soil Pipe
610Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
611Supplying and erecting circular flexible/rigid PVC pipe duct of size 200mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete.
612Providing and fixing 15cmx10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
613Gully trap cover with frame
614Providing and constructing Ductile Iron circular manhole 45cm dia. At top 90cm at bottom upto 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15cm thick burnt brick mansonry with 1:1 cement mortar plaster 25mm thick inside and outside 20mm (1:3) ductile iron heavy type cover withring 125Kilogram in weight.High strength. More life and Durability ,Good Anti skid Grip,Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer.
615Providing and fixing Ductile iron manhole cover of light/medium/heavy duty with frame of any size over inspection chamber etc. complete (Prior permission of S.E. is to be obtained before inclusion of this item in the estimate)
616Ball cock for 32mm dia.
617Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete
618Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
619Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
620Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
621Supplying and erecting non return valve 65 mm dia in position made of gun metal complete.
622Supplying and erecting non return valve 75/80mm dia in position made of gun metal complete.
623Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete
624Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 3.75 KW/5 HP with discharge 715/200 Litres per Minute (LPM) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as perspecification No. WP-CGP
625Supplying & erecting Dewatering Monoblock pump set 415V, 3 phase, 50C/s, A.C. supply of 5.5KW/ 7.5 H.P., of 21 to 36 m head with 910 to 190 LPM discharge, 14.5mm Solid Handling Capacity, non-clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP
626RWH-Shallow Percolation Pit providing,constructing 2.0m deep shallow depth percolation pit comprisingof 1.0m dia pre-cast RCC rings,300 mm thick side filling around outside of RCC rings(annular space) with 40mm size boulder including filling of percolation pit upto 0.5m depth(from bottom up)with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fin aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab,manhole frame & cover,PVC rungs etc.including arrangement for inlet &outlet pipe,excavation & back filling as shown in the drawing.The rate shall be inclusive of all labour,material,wastage,scaffolding,transportation,taxes,including all leads,lifts at all levels.All material should be of approved make.All works complete as per the drawing, technical specification and direction of the Engineer in charge.
627supplying, installaing, testing & commissioining of skid mounted packaged type sewage treatment plant complete with electromechanical equipments such as Manual type bar screen of 10 mm openings constructed of MS eposxy coated, Coarse aeration system of UPVC, sewage transfer pumps constructed of CI impellar for solid material handling of 10-15 mm size & liquid with specific gravity of 1.05 at ambient temperature ( one working & one standby) , Bio reactor chambers constructed of MSEP, Reactor aeration systems constrcuted of diffused aeration system of UPVC, FBBR( Fludized bed Bio Reactor) media constructed of UV Resistant PP ( Polypropylene) suitable for 400 sqm/ Cum, Lamella settler process Chmaber constructed of MSEP, Tube Settler media constructed of PVC tube media 750 mm Vertical Height 11 sqm/ cum at 60 degree with approx weight of 75 kg/cum UV stabilised PVC, Air Blowers Constructed of CI positive displacement creating pressure of 0.5 Kg /sqcm with horizontal foot mounted motor ( Air Blower with Motor-one working & one standby), Chlorine Cintact tank constructed of HDPE, Chlorine dosing system constrcuted of electroinic dosing pump with dosing tank in HDPE, All interconnected piping, Valves & fitting within STP constructed of UPVC, Sludge pumps constructed in CI impellar & Housing ( only working pump), Dual Media Filter Constructed in FRP with MPV, UPVC Piping & Media, Feed Pump for treated water in SS-304 Contruction for Impellar & Housing ( One Working+ One standby), Motor Control centre Complete with starters, contactors, overload relays etc for all pumps & Blowers, Electrical cabling & Glands from Motor Control Centre to all pumps & blowers, With Civil constructed items such as Screen Chamber of suitable volume size, Oil & Greese Chamber of suitable volume , Sewage Collection Tank of suitable Volume , Foundations for STP Skid, Pumps Blowers etc in RCC of 150 mm thick , Treated water Sump of suitable volume in HPDE & Sludge Draying bed Constrcuted in Brick Masonary. For the Capacity of 150 M³/ day with design flow rate of 20.0 M³/hr with design parameters max values of inlet as BOD- 250 ppm/ COD-500 ppm /TSS-250 ppm /Oil & Greese- less than 20 ppm & for outlet as BOD- less than 20 ppm/ COD-less than 80 ppm /TSS-less than 20 ppm /Oil & Greese- Nil ppm / pH- 7-8. The treated water shall be used for Horticulture, gardening & Toilet Flushing. ( All civil work is included in the scope. All sizes and design to be approved from engineer incharge)
628SEWAGE TREATMENT PLANT Supply, Fabrication, installation, testing and commisioning of Fully automatic sewage treatment plant based on MBBR process with sewage handling capacity 142 m3 per day. The STP shall be designed as water retaining structures, with necessary chemical dosing as required by the manufacturer"s design. All the equipment, piping, pumps, air blowers and electrical panel to be housed in the STP. The cost will also include M.S. puddle flange (Galvanised), inlet, outlet, overflow, vent, Foot rest, moving ladders & railing and making support for piping.(The entire plant will be constructed in RCC. ) Domestic Sewage from Toilets, kitchen and Laundry effluent. Design to take consideration of the same. Daily average flow : 142 M3/DayEffleunt Parameter at Inlet to STP:-PH : 7.0 - 7.5BOD : 250 - 300 mg/lS. Solids : 250 - 400 Mg/lOil & Grease : 50- 100 mg/LCOD : 350 -400 mg/lEffluent discharge standard after treatment :-PH : 6.5 - 8.0BOD : Less than 10 mg/lS. Solids : Less than 10 mg/lOil & Grease : Less than 10 mg/lCOD : Less than 40 mg/lSewage treatment plant shall include the following items:Screen Chamber, Oil & Grease Trap, Sewage equalization tank/sump , Aeration Tank cum MBBR Reactor, Secondary Tube Settler Tank, Sludge Holding Tank, UV System, Air Blowers, Pumps & equipment, Piping, valves etc Irrigation / Flushing Water tank, Soft Water tank, Electrical Panel & Cabling, Centrifuge systemContractor shall ensure submission of detailed GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP. The following list of civil units shall be Client"s Scope. Oil & Grease Chamber, Equalization Tank, Reactor Tank, Tube Settler System, Filter Feed Tank, Main Sludge, Holding Tank. Treated Water Tank, Soft Water Tank, Drain Sump for STP room, Foundations for all the units, Centrifuge System Pretreatment Supply, installation, testing & commissioning of 2 Nos 304 Stainless Steel Perforated, Corrugated Bar Screen with suitable lifting arrangement of following sizes: (size 450 mm wide x 600 mm high approx).
629Secondary Treatment MBBR reactors (2 compartments) of 142 m3 per day with media, air diffuser and piping of adequate capacity. Fine air bubble jet diffuser with EPDM seat minimum number of diffusers to be provided as per manufacturer"s recommendations in RCC Construction. (Tank in Owner"s supply).
630Air diffuser system with 2 nos. twin-type air blower of capacity suitable for 110 m3/day at the pressure of 0.50 kg/cm2 each including fine bubble membrane type diffusers complete with valves & air distribution grid, flexible pipie etc. complete as required. (One set consists of 2 nos. of blower (1 working+ 1 standby)
631Providing and fixing all piping (as described below) and isolation control valves, non return valves etc. for making the system complete. PVC piping (10kg/sqcm) - For all submerged waste water piping. MS (C Class) - For all exposed air piping and flexible braded pipe for submerged air piping.
632Providing and fixing all instrumentation eg. Pressure guages, level controllers, sensors, rotametres for air, water etc. for making the system complete. ISI MARKED
633EQUALIZED WASTE WATER TRANSFER PUMPS :Providing and fixing fully submersible sewage handling type pump for raw sewage transfer . The pump shall have complete SS construction, TEFC induction motor including pressure gauge, lifting arrangement for the pump, all necessary piping, valves, cable etc. and other accessories as required Solid handling shall be 40 mm.Capacity : 12 M3/hr , Operating Hr : 12 Hr, Discharge Head 10 M head , 1 Set = 2 Pumps (1 Working + 1 Standby)
634DIGESTED SLUDGE DISPOSAL PUMP :Providing and fixing screw Sludge disposal pump for the disposal of sludge to tanker or to Filter Press. The pumps shall have CI casing, bronze Impeller & SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for including all necessary piping, valves and other accessories and concrete foundation complete as required. (1 Working + 1 Stand-by) Capacity 7 m3/hr , Discharge Head : 40 mtr head, 1 Set = 2 Pumps (1 Working + 1 Standby)
635FILTER FEED PUMPS :Providing and fixing Horizontal centrifugal pumps for filtration. The pumps shall be made of CI casing, bronze Impellar, SS shaft & sleeve, Mechanical Seal are connected to a TEFC induction motor mounted on a common channel base frame with coupling guard, 150 mm dia pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design. Motor to be suitable for 400/440 V, 3 Phase, 50 cycles AC power supply, including all necessary piping, valves and other accessories and concrete foundation complete as required. Capacity 14.2 M3/Hr. , Operating Hr : 10 Hr, Discharge Head : 35M head, 1 Set = 2 Pumps (1 Working + 1 Standby)
636MULTIGRADE SAND FILTER :Installation, testing & commissioning of vertical self supporting Dual Media Filter (DMF) fabricated from FRP, complete with pressure gauges at inlet & outlet, sample cock, multiport valves, PVC face piping with ABS multiport valves and all accessories, with initial charge of filter media for Dual media filter with multi grade quartz sand & anthracite, lining inside with PP and FRP wounded outside, testing and commissioning complete.Capacity : 14.2 M3/hrFiltration rate : 18-20 M3/M2/hr Max. operating pressure : 3.5 kg/sq.cm Test pressure : 5.5 Kg/Sq.cm
637ACTIVATED CARBON FILTER :Installation, testing & commissioning of vertical self supporting Activated Carbon Filter (ACF) fabricated from FRP, complete with pressure gauges at inlet & outlet, sample cock, PVC face piping with ABS multiport valves and all accessories, with initial charge of filter media for activated carbon filter, lining inside with PP and FRP wounded outside, testing and commissioning complete.Capacity : 14.2 M3/hrFiltration rate : 18-20 M3/M2/hr Max. operating pressure : 3.5 kg/sq.cm Test pressure : 5.5 Kg/Sq.cm
638CHLORINE DOSING Supplying, Installation, testing and commissioning of Chemical dosing system compromising of Sintex Tank with inlet/ outlet connection, piping and valves alongwith metering pump of 5 LPH for dosing.
639Ultra Violet Disinfection System Supply, installing, testing & commissioning of ultraviolet dis-infection unit. The unit shall have over 99.9 % bacterial reduction from inlet to outlet. The dis-infection chamber shall be constructed of SS 316L on all welted parts. The UV lamp shall be of low pressure mercury vapour type with hard glass enclosure, the sockets shall be water tight & vibration resistant. The lamp life shall be rated for 6000 hours. The unit shall be complete with temperature safety control, lamp out alert circuit & UV radiometer with 4 – 20 mA output. The UV unit shall have with reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lamp out alert, UV radiometer along with UV monitoring system and UV monitoring readout panel. The UV Dosage should be > 60,000 uW – Sec / sq.cm. The lamps should be selected based upon the flow requirement of respective unit. Flow - 8.0 M3/hr
640Providing, Erection & commissioning of PP plate, CI base frame Filter Press with manual operation mechanism. The Filter press should be complete with frame , filter cloth, handle, effluent water tray & sludge disposal tray. Suitable for sludge generated from 50m3/day sewage flow. No of Plates : 9 Nos.
641Hydropneumatic pumps (basement & guest floors)Supply, installation, testing and commissioning of the compact self contained hydropneumatic system including the following: Variable Frequency Drive System: 2 Nos. Vertical centrifugal (direct coupled) pumps with SS-304 casing & impeller, SS -316, shaft, CI base & head TEFC motor (with mechanical seal) mounted on a common M.S. structural frame work, including Treated water tank to common suction header with flange for inlet connection, common outlet, G.I header with flange for outlet connections and interconnecting piping with isolating valves, Strainer, non-return valves, pressure gauges with isolation cock etc. Precharged diaphragm pressure vessel FRP of suitable size and nos. for the system mentioned below with charging connection, connected to outlet header with necessary flanges, gaskets, isolating, valves, nuts/bolts etc. complete. Fully automatic control panel including starters, instruments, incoming isolator, level control for low water gaurd for pumps, microprocess based PLC, variable frequency drive (VFD), pressure transmitter, low and high system pressure switch with alarm auto/manual selector switches, interconnecting power control cabling etc. all accessories which required to complete the system for working conditions as per specifications. Hydropneumatic system as described above as under given capacities and areas:Capacity- 9.00 M3/hrDischarge Head : 45 - 50 Mtrs.Working Pressure : 2.5 Bar End pointApprox H.P. - 6 HP or as per manufacture recommendationFor - Flushing water supply1 Set (2 Nos Pumps. 1 Warking + 1 Standby)
642Capacity- 10.0 M3/hrDischarge Head : 55 - 60 Mtrs.Working Pressure : 2.5 Bar End pointApprox H.P. - 6 HP or as per manufacture recommendationFor - Irrigation water supply1 Set (2 Nos Pumps. 1 Warking + 1 Standby)
643Submerssible Sump Pump Providing and fixing fully submersible drainage pump for sump dewatering including pressure gauge, lifting arrangement for the pump, all necessary piping, valves, level controller for their automatic operation, cable etc. and other accessories as required. Solid handling shall be 12 mm.(1 Working + 1 Stand-by) Capacity- 150 LPM @15m
644ELECTRICAL CONTROL PANEL Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3 formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Galvanised hardware with zinc passivation shall be used in fabrication of panels. MCC-1 (STP Motor Control Centre)Incoming100 amps TPN MCCB with the following accessories: 0-500 volts 96 x 96 mm square digital electronic voltmeter with selector switch shall be protected by 2 amps TP MCB. 1 Set 0-100 amps 96 x 96 mm square digital electronic ammeter with selector switch and 100/5 amps 15 VA CL: 1 CTs. 1 Set Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets Bus Bar200 amps TPN (25 KA) copper bus bar with heat shrinkable insulation sleeves. Outgoing2 Nos. 32 Amp 4 Pole MPCB for 3.0 H.P. direct on line starter and out going feeders to submersible pumps in Equilization tank. Each compartment shall contain direct operated digital electronic ammeter 0-16 amps range with auto/manual selector switch and indicating lamp with MCB’s and ‘ON/OFF/TRIP’ status of motor 2 Nos. 32 Amp TPN MPCB for 7 HP direct on line starter and outgoing feeder to air roots (1 W + 1S) blowers pump. Each compartment shall contain CT operated digital electronic ammeter of 0-16 amps range with auto/manual selector switch and indicating lamps with MCB’s and ‘ON/OFF/TRIP’ status of motor 2 Nos. 32 Amp TPN MPCB for 3.0 HP direct on line starter and outgoing feeders to 2 Nos. of (1 working + 1 standby) filter feed pump. Each compartment shall contain direct operated digital ammeter of 0-16 amps range, auto/manual selector switch and indicating lamps with MCB and ‘ON/OFF/TRIP’ status of motor 2 Nos. 32 Amp TPN MPCB for 3.0 HP direct on line starter and outgoing feeders to 2 Nos. of (1 working + 1 standby) sludge disposal pump. Each compartment shall contain direct operated digital ammeter of 0-16 amps range, auto/manual selector switch and indicating lamps with MCB and ‘ON/OFF/TRIP’ status of motor 1 Nos. 5 Amp TPN MPCB for direct on line starter and outgoing feeders to UV system, auto/manual selector switch and indicating lamps with MCB’s and ‘ON/OFF/TRIP’ status of motor 2 Nos. 16 Amp TPN MPCB for 1 HP direct on line starter (1 W + 1S) and outgoing feeders to garden irrigation pumps. Each compartment shall contain C T operated 0-16 amps range digital ammeter with selector switch, auto/manual selector switch and indicating lamps with MCB’s and ‘ON/OFF/TRIP’ status of motor 2 Nos. 20 Amp TPN MPCB for 3 HP direct on line starter (1 W + 1S) and outgoing feeders to flushing water lifting pumps. Each compartment shall contain C T operated 0-20 amps range digital ammeter with selector switch, auto/manual selector switch and indicating lamps with MCB’s and ‘ON/OFF/TRIP’ status of motor 2 Nos 16 Amp TPN MPCB for 1 HP direct on line start (including 1 No standby) and outgoing feeders to drainage sump pumps. Each compartment shall contain direct operated digital ammeter of 0-16 amps range, auto/manual selector switch and indicating lamps with MCB and ‘ON/OFF/TRIP’ status of motor Spare of following capacities: 32 amps 4 Pole MCCB 2 Nos.63 amps TPN MCCB 2 Nos. Necessary cable alleys, internal wiring, cabling from STP plant to individual equipment including interlocking, earthing shall also included in the quoted price. No extra claim in this regards shall be payable beyond quoted in panel price.MCC-1 for STP as described above
645WATER TREATMENT PLANT Variable Speed Hydropneumatic System for Domestic Water Supply Distribution to all Toilets :Supply installation testing & Commissioning of Factory supplied package type (Skid Mounted) compact self contained Hydropneumatic system comprising of following : In-line, multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base & head TEFC motor (with mechanical seal) Vendor to submit performance curves dimension detail and technical catalogue of the proposed model for review and approval. Duty Parameter of VFD system:Capacity/Flow rate : 16.5 m3/hr. of each pump Pumping Head : 70 - 75 mPower Requirement (kw) : 6.0 KW each pump as per manufacture recommendation1 Set : 2 Nos. pump (1w+1s) Panel mounted microprocessor PID controller and variable frequency drive (VFD) integrated in a single body or as separate components with pressure sensor transmitter (one dedicated to each pump) minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. (Quantity of VFD = 2 Nos. (1w+1s) Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be of 100 liters (approx.) or as per manufacturer recommendation / calculation).Set of accessories such stainless steel GI suction & delivery header, GI interconnecting piping, valves (Ball valve / Butterfly valve / NRV"s of PN 10 kg / cm2 rating), pressure switches, pressure transducers, level controller, pressure gauge inter connecting power and control cabling etc. complete.
646WATER TRANSFER PUMP SYSTEM Supply, Installation, testing and commissioning of vertical, inline multistage centrifugal pumping set (Complete manufactured Skid-Mounted arrangement with manifold and accessories) with SS-304 casing & impeller, SS-316 shaft and SS-304 suction & discharge casing, connected to TEFC ventilated induction motor (with mechanical seal) of 2 pole, 2900 RPM, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply with pressure gauge with gunmetal isolation cocks, butterfly valves, Non- return valve, vibration elimination pads and complete suction & discharge piping with flanges etc. complete with base and frame, nuts and bolts and necessary RCC foundations as per equipment manufacturer"s recommendations, Pump shall have following duty: Duty Parameter of Filter Feed Pump:Capacity/Flow Rate - 10.80 M3/hour (Each)Pumping Head - 30 - 35 mtrMotor kW - 4 KW / as per manufacture recommendationType of Pump - Vertical, inline centrifugal pumping1 Set - 2 Nos. pump (1 W +1 S)
647WATER TREATMENT EQUIPMENTS :MULTI GRADE PRESSURE SAND FILTER (MGF):Supply, installation, testing and commissioning of vertical self supporting Multi Grade Pressure Sand Filter. Filter shall be constructed of FRP/composit material with inner shell of integrated Polyethylene with Fiber Reinforced Plastic as per manufacturer standard. The inner distribution system and the under bed draw off system shall be of Hub & Lateral type/ Riser tube with top & bottom strainers of Polypropylene material. Filter shall be supplied with initial charge of Filter media like special graded sand with supporting media like silex, gravel etc. The filter shall complete with frontal piping/ interconnected piping, Manual Multiport valve including Pressure gauge at inlet & outlet, sample point, other necessary Fittings & Accessory to make System Function.FRP Multi Grade Pressure Sand Filter:Feed Flow - 10.8 M3/hrFiltration rate/velocity - 18 M3/M2/hr Operating/working pressure - 3.0 kg/Sq.cmTest pressure - 4.5 kg/Sq.cmMode of operation - Manual Multiport Valve
648ACTIVATED CARBON FILTER [ACF] : Supply, installation, testing and commissioning of vertical self supporting Activated Carbon Filter. Activated Carbon Filter shall be constructed of FRP/composit material with inner shell of integrated Polyethylene with Fiber Reinforced Plastic as per manufacturer standard. The inner distribution system and the under bed draw off system shall be of Hub & Lateral type/ Riser tube with top & bottom strainers of Polypropylene material. Filter shall be supplied with initial charge of media like Activated Carbon Media of 900 iodine value, with supporting media like silex, gravel etc. The filter shall be complete with frontal piping/interconnected piping, Manual Multiport valve, and all necessary accessories.Duty Parameter of Activated Carbon Filter:Feed Flow - 10.8 M3/hrFiltration rate/velocity - 18 M3/M2/hr Operating/working pressure - 3.0 kg/Sq.cm Test pressure - 4.5 kg/Sq.cm Mode of operation -: Manual Multiport Valve
649WATER SOFTENER :Supply, installation, testing and commissioning of vertical self supporting Softner. Filter shall be constructed of FRP/ composit material with inner shell of integrated Polyethylene with Fiber Reinforced Plastic as per manufacturer standard. Softener shall be supplied with initial charge of Purolite Resin to cater High hardness. The filter shall complete with frontal piping / interconnected, Manual Multiport valve / Manual Butterfly Valve SOFTENER WITH BRINE TANK FOR DOMESTIC WATER SUPPLY SYSTEM :. HardnessInlet - 400 PPM (Approx)Outlet - less than 50 PPMFeed Flow - 10800 LPH (10.80 m3/hour)Regeneration Period - 8.0 hrs. OBR - 120 m3Working pressure - 3.0 Kg/Sq.cmTest pressure - 4.5 Kg/Sq.cmBrine Tank [MS FRP] Capacity - 100 LitersMode of operation - Butterfly Valves / Multiport Valves
650Supplying, installing, testing and commissioning of dosing system consisting of one HDPE tank of 100 litres capacity with a positive displacement diphragm dosing pump for Chlorine Dosing having variable flowrate of 0-6 lph. The motor shall be suitable for peration at 240 V / single phase /50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. Chlorination of Domestic Water [CDP] :
651UV Sterilizer: Supply, Installation, testing & commissioning of online SS 316 UV Sterlizer suitable for UV Dosage >60000m w-sec/cm2 following flow rate. Complete with UV Intensitty Monitor all fitting & accessories, bypass arrangement including piping & 3 Nos. Isolation valve complete Maximum operating Pressure Shall be 120 Psig. At Domestic water supply line Flow 10.80 m3/hr.
652Supplying complete testing kit with all chemicals complete suitable for conducting test on water quantity. The test kit shall be suitable for measuring, TDS, PH, hardness, iron content etc.
653PIPING,VALVES & ACCESSORIES RELATED TO WTP, UG TANK & OH TANK :Supply, installation, testing & commissioning of G.I. Pipes Class "C" conforming to I.S. 1239 (Heavy grade) with G.I. Fittings conforming to IS : 1879 (Part I to X) such as tees, crosses, plugh, socket, elbows, reducers, flange, check nut, flanges & clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the walls etc. complete.
654Painting G.I. Pipes (heavy class) with two or more coats of synthetic enamel paint of approved quality and shade over a coat of approved priming coat as directed by the Project Manager (shade as per pipe colour code).
655Ball Valve : Providing and fixing Ball valve with hard chrome plated ball inside PTEF (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respect. 40 mm dia
656Supply, installation, testing & commissioning of CI dual plate type non-return valve (PN 16) complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 40 mm dia (Gun Metal)
65750 mm dia (Cast Iron)
65865 mm dia (Cast Iron)
65980 mm dia (Cast Iron)
660Supply, installation, testing & commissioning of CI slim seal butterfly valves Class (PN 10) complete with 2 Nos. matching flanges rubber insertion, nuts, bolts and washer etc. of following sizes :- 50 mm dia
66165 mm dia
66280 mm dia
663Providing & fixing resilient rubber neoprene lined style arch vibration eliminators suitable upto pressure 20 kg. /Sqcm. 65 mm dia
66480 mm dia
665Providing and fixing C.I. Basket strainer/Y type suction strainer with gunmetal or brass internal parts installed outside water. 50 mm dia
66665 mm dia
66780 mm dia
668Providing & fixing dial type (100 mm dia) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2.
669Providing, fixing, testing and commissioning of Digital Water meter (turbine type water meter) compatible with BMS (to be integrated with BMS) with direct reading dia in Kilo-liter with all internal part in Gun metal or brass, strainer, flanged distance pieces for easy removal, 100 mm dia burden type pressure gauge with isolation cock including necessary test certificates for the meter from authority. The water meter shall complies with EEC Directive/ISO standards. One 65/80 mm dia [Distribution of Domestic water Supply].
670Providing, fixing, testing and commissioning of Fully Automatic micro-controller based water level Controller and Water-Level LCD Display & motor protector including sensor, Display Panel, cabling and all fitting and accessories (For Underground Water Tanks).
671Supply, Installation, testing commissioning of Fully Automatic micro-controller based water level Controller and Water-Level LCD Display panel suitable to operate 24V DC/50 HZ solenoid based on the level of the tank including level sensors, 02 Nos. of float switches and solenoid valve of suitable size(For Overhead Water Tanks)
672WTP Panel :Incoming: One (1) No. 100A, 4P MCCB. One (1) No. digital multifunction meter for measurement of voltage and currents with selector push buttons and one set of CTS of ratio 100A/5A, CL 1.0, 5 VA.(ELF-3259 of Conzerv or equivalent) One (1) set of R, Y, B phase indication lamps and ON/OFF/Trip indication Lamps with control SPMCB. One (1) Set of SPD Type-2 Busbars : 150A TPN, 16KA, Aluminium busbar insulated with heat shrinkable sleeves and shall be color coded. Outgoings: 2 Nos.63A TPN MCCB2 Nos.40A TPN MCCB1 Nos.63A TPN MCB1 Nos.32A TPN MCB1 Nos.25A DP MCB 3 Nos. DOL Starters, suitable for 3.0 KW motor, complete with suitable range of TP MPCB with thermal range as per Type-II co-ordination chart. WTP Panel as described above and as per SLD.
673Cables, Submains & Cable Trays: Supply, installation, testing and commissioning of following sizes of PVC sheathed XLPE insulated Aluminium /Copper conductor/ power/control armoured cables of 1100V grade on surface of wall or in existing cable trays with fixing hardware etc. as required. (Suitable for above mension item)
674Cable Termination : Supply & making end termination with brass Double compression glands for the following XLPE insulated PVC sheathed 1100 V grade cable including cost of crimping lugs/ ferrules, compression glands, solder, cable sockets, insulation tape etc. complete. (Suitable for above mension item)
675Cable Trays: Supply and installation of ladder type/perforated type cable trays of the following sizes fabricated out of perforated hot dip galvanised MS sheets of minimum 2 mm thick with 75 mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers, supporting arrangements etc as per drawings/site condition and as required. (Suitable for above mension item)
676Supply, installation, testing & commissioning of following size G.I. Strip/G.I. wire clamped to existing cable tray, wall for system/equipment earthing complete as required including interconnection etc.
677SUBSTATION EQUIPMENT 22 kV HT PANEL ( 1 I/C & 2 Transformer O/G) Supplying, installing, testing and commissioning 22 kV 630A, vacuum circuit breaker with internal arc compliance complete erected on provided cc foundation/MS channels/trench, etc., as per specification no SW-HTS / VCB
6781000kVA, 22/0.415 KV OIL TYPE TRANSFORMERS Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 1000 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2930 Watts at 50% load, 8085 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRSL.
679HT CABLE Supplying, erecting & terminating XLPE insulated, galvanised steel formed wire armoured (Round) cable 22 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
680Providing and erecting Heat shrinkable indoor termination kit for 33 kV ( E) /33 kV (UE) XLPE HT cable 3x300 sq. mm. to 400 sq. mm. with necessary material as per specification no. CB-JT/HT
681Supply, installation, testing and commissioning of 100AH capacity 24 volts DC hermetically sealed maintenance free lead acid batteries duly charged including battery charger unit with provisions of Boost Charing, and Float charging. Suitable for 240 V, including DC DB single phase + 10% AC, 50 Hz supply as per specifications .
682Supply & Laying of non skid Electro mat 1mtr wide and 3.0 mm thick 22KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
683Supply and fixing in position the approved “Shock Treatment Charts” written in English and Local Language. These charts shall be framed in teak wood frame and covered with glass.
684Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
685Supply and fixing position the approved single line diagram framed in 1000 x 100 mm size glass frame and installed in main LT Panel Room.
686Supply of tool kit, first aid box with all accessories required for operation and maintainence for 415 volt & 11 kV equipment with 1 pair 11 kV rubber hand gloves of approved make.
687DG SET & ACCESSERIES Supplying, erecting, testing and commissioning of diesel generating set with alternator of 750 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 126.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 990 Ltr tc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
688Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr tc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
689EXHAUST PIPING Providing, fixing, installing, testing and commissioning of exhaust pipe of following dia fabricated out of 6 mm thick MS plate and all fixing accessories and hardwires. Supplying and fixing of first layer of 25 mm thick Ceramic wool (96 Kg. Per cubic RMT density) and second layer of 75 mm thick Rockwool insulation (of 150 Kg. Per cubic RMT density) over the exhaust pipes of following diameter including cladding, wrapped in chicken mesh with aluminium sheet of 26 SWG and covering from outside complete, as required. Exhaust pipe shall be inclusive of required supporting structure including heat resistant paint etc complete in all respect as required for successful operation of DG set in compliance with CPCB norms. Expansion bellows shall be provided at necessary location. 250 mm dia
690350 mm dia
691Supplying, laying, tesing & commissioning of following 1100 volt grade XLPE insulated PVC sheathed Aluminium/Copper conductor armoured/Unarmored cables as per specification in cable trays / ducts clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning complete in all respect as required as per site conditions. 12 core 2.5 sq.mm shielded Cu. Cable
6924 core 2.5 sq.mm Cu arm. Cable
6932 core 4 sq.mm Cu arm. Cable
69412 core 1.5 sq.mm shielded Cu. Cable
695Supplying and making Cable end termination of the following XLPE insulated PVC sheathed copper conductor armoured cables of 1100 volt grade including supplying and fixing of Copper crimping lugs, double compression glands with earthing testing and commissioning complete in all respect as required as per site conditions. 4 core 2.5 sq.mm Cu arm.
69612 core 2.5 sq.mm Cu arm.
6972 core 4 sq.mm Cu arm.The rates for the distribution boards apart from the Breakers and instruments shall also include the following : Supporting rigid steel framework. Cubicle type, 16 gauge CRCA sheet steel enclosed & Type 3b modular construction. Complete with interconnections and distribution bus bars along with connector strip. Proper bonding to earth as per standard. Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. Providing cable clamps / supports within distribution boards cable alley. All MCB’s shall be of minimum 10 KA breaking capacity. Distribution panels / bus ducts / rising mains shall be Powder Coated with RAL-7032 shade or as approved. Following Degree of protection for all type of distribution panel enclosure shall be as per IS:13947-1993:IP 44 for indoor panels.IP 54 for kitchen and laundry panels.IP 65 for outdoor panels. Current density of aluminium shall be 1 sq mm for 1.0 Amps for rated current of bus bars. GI earth bus shall be provided through out the length of each board as per schematic diagram. All measuring instruments (Meters) shall be of digital electronic (LED Type) of approved make. All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. All panels shall have provision of the Pad locking of MCCB’s handles in “OFF” Position. Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in main LT panel sections, etc. Only transducers shall be supplied by BAS tenderer. All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. CT’s shall be properly mounted and clamped. Connection of CT’s for measuring instrument / relays shall be done through connector / terminals. Model, current capacity location and frame size of switchgear shall be written inside of the panel doors with paint / permanent marker as approved shop drawings / site requirement. All electronic meters with RS - 485 port and ACB"s communication port shall be wired with shielded wire upto separate marshalling box for termination of all control wires and communication system. Compliance to the technical specifications.LT PANELS & DISTRIBUTION BOARDSDesign, fabrication, assembling, wiring and supply, installation, testing and commissioning of Main LT Panels fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 4b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels.All Panels shall conform to relevant IEC/IS (viz. IEC 61439, IS 8623 etc.) standard including the earth leakage protection complete as per specification & drawings as required and as given below. All internal wiring in the panels shall be carried out using high temperature FRLSZH wires.All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars shall be insulated with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports suitably spaced shall be used. Hinged doors with padlocking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position.Space provision @ 15% for future expansionAll MCCBs shall be current limiting type microprocessor based, rated for requisite specified Service short circuit breaking capacity (Ics suitable for isolation conforming to latest IEC947-2/IS13947-2 duly marked on MCCB, at operating voltage (Ue) of 415 V, insulation voltage (Ui) 750 V and with trip free mechanism, handle indicating ON/OFF/tripped position. The breaking capacity as mentioned shall be Ics values.All MCCB has inbuilt feature of earth fault protection.MCCBs shall be compact (As the Engineer may decide), suitably designed to provide protection of motors, cables, busbars to suit rated current, unbalanced power distribution as required and with front adjustable overload and short circuit releases and minimum electrical endurance of the order of 7000-8000 operation cycles for capacity of 100-250 amps.MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking capacity 9/10 kA at 415 V AC, current limiting type lower powerloss appx 40 - 70% of the stipulated value and suitable for magnetic releases operating between 3 to 5 times rated current for normal power distribution application and 5 to 10 times rated current for moter application duty, with minimum Electrical endurance of the order of 20000 operation cycles.
698MAIN LT PANEL CUM CHANGEOVER PANEL Incomer from transformer - 1 & 2, each comprising of: 1600 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. The release shall have following protection: • Over current• Short Circuit (S), • Ground Fault (G), Maximum demand, Fault History records, Event records facilities, LED display, % loading with adjustable setting as per specification - 1 Set Multifunction meter for disturbance direction detection with sag/swell monitoring and waveform capture, harmonic analyser utpo 63rd order, V,A, KWHr, Hz, P, kVAR with CT"s and dual ethernet communication port equivalent to Schneider make PM8000 - 1 SetBreaker ON / OFF / TRIP, Ready to close contact & indicating lights with control MCB - 1 SetPhase sequence relay - 1 SetRYB Phase indicating light protected by 2 amps MCB’s. - 1 SetAuto-manual / test selector / switch - 1 Set 110 V DC Shunt trip coil. - 1 SetUnder Voltage and over voltage relay (27 & 59) with timer - 1 SetUnder / over frequency relay (81) - 1 SetClass – B surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. 2 No. Incomer from DG Sync Panel, each comprising of: 1600 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. The release shall have following protection: • Over current• Short Circuit (S), • Ground Fault (G), Maximum demand, Fault History records, Event records facilities, LED display, % loading with adjustable setting as per specification - 1 SetMultifunction meter for disturbance direction detection with sag/swell monitoring and waveform capture, harmonic analyser utpo 63rd order, V,A, KWHr, Hz, P, kVAR with CT"s and dual ethernet communication port equivalent to Schneider make PM8000 - 1 SetBreaker ON / OFF / TRIP, Ready to close contact & indicating lights with control MCB - 1 SetPhase sequence relay - 1 SetRYB Phase indicating light protected by 2 amps MCB’s. - 1 SetAuto-manual / test selector / switch - 1 Set 110 V DC Shunt trip coil. - 1 SetUnder Voltage and over voltage relay (27 & 59) with timer - 1 SetUnder / over frequency relay (81) - 1 SetClass – B surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Coupler comprising of 1600 amps 4 pole EDO ACB with ON / OFF / TRIP indicating lamps with control MCB’s, shunt trip, breaker control switch etc. - 1 Set Bus Bar comprising of : 2000 Amps 4 Pole Aluminium Bus Bar throughout the panel with colour coded heat shrinkable steeve Outgoing comprising of : 1000 Amps TPN EDO ACB with Microprocessor based releases for SC, OL & EF protections etc. - 6 Set 800 Amps TPN EDO ACB with Microprocessor based releases for SC, OL & EF protections etc. - 6 Set 630 Amps TPN MCCB with Microprocessor based releases for SC, OL & EF protections etc. - 6 Set 400 Amps TPN MCCB with Microprocessor based releases for SC, OL & EF protections etc. - 3 Set 200 Amps TPN MCCB with Thermalmagnetic based releases for SC & OL protection etc. - 4 Set 160 Amps TPN MCCB with Thermalmagnetic based releases for SC & OL protection etc. - 2 Set 100 Amps TPN MCCB with Thermalmagnetic based releases for SC & OL protection etc. - 4 Set Notes:-All Outgoing feeders shall be provided with Dual Energy Meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6438H and all meters wired at one point for BMS compatibility.All ACB, MCCB RS 485 ports and meters shall be wired at one point for BMS compatibility.All Outgoing feeders shall be provided with Three phase indicating lamps protected by 2 amps SP MCBs.All Outgoing feeders shall be provided with ON/OFF/TRIP Indications and shall be protected by 2 amps SP MCBs.All incoming and outgoing breakers shall be electrically/ mechanically interlocked through a Load Sharing cum Synchronization PLC comprising suitable nos. digital inputs (24 VDC) and output (Relay) for auto operation of DGs as per load requirement. PLC bypass shall also be provided. Provision for manual synchronization of DG set thru PLC shall also be provided.All incoming, outgoing and buscoupler breakers shall be minimum 35 kA rating with Icu = Ics.Each section of the panel shall be provided with LED light & limit switch, space heater and thermostat etc.Suitable Quantity Novec 1230 gas based suppression system with gas bank, Linear Pneumatic heat trace tubing system along with associated automatic valves, connectors, brackets, mounting accessories, Low pressure switch for monitoring system activation, Audio Visual alarm shall be provided for all vertical & horizontal compartments in Panel.Transformer & DG Section shall be in Blue & Orange Colour. Bus Coupler shall be in Green Colour.All outgoing breakers shall have Z CT & EF relay.1600/5, 15 VA dual ratio CT’s shall be provided for APFCR on each transformer incomer.
699250 kVAR Capacitor Panel : Incomer comprising of : 630 amps 4 Pole MCCB with Microprocessor based release unit for O/L, S/C & E/F protection- 1 SetMicroprocessor APFC controller shall continuously monitor all three phases and displays various Electrical Parameters like voltage, input current, capacitive current, KVA demand, KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232C port. Controller should mounted on the front side of the panel. It shall have data logging for minimum 2 months, it shall provide output for maximum 8 stages.Multifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 630/5 15 VA, CL 1, 3 No. CTs- 1 SetBreaker ON / OFF / TRIP indicating lights with control MCB - 1 SetPhase indicating light protected by 2 amps MCB’s. - 1 Set Bus Bar comprising of : 800 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable steeve - 1 set Outgoing comprising of : 50 kVAR Capacitor Bank - 2 Set, each comprising of following:125 Amps TPN MCCB - 1 Set125 amps or capacitor duty 525 volts 50Hz contactors. - 1 Set“ON” /”OFF” push buttons and indicating lamps. - 1 Set50 kVAR, 525 volts capacitor unit as specified - 1 Set 25 kVAR Capacitor Bank - 4 Set each comprising of following:80 Amps TPN MCCB - 1 Set80 amps or capacitor duty 525 volts 50Hz contactors. - 1 Set“ON” /”OFF” push buttons and indicating lamps. - 1 Set25 kVAR, 525 volts capacitor unit as specified - 1 Set 12.5 kVAR Capacitor Bank - 2 Set each comprising of following:40 Amps TPN MCCB - 1 Set40 amps or capacitor duty 525 volts 50Hz contactors. - 1 Set“ON” /”OFF” push buttons and indicating lamps. - 1 Set12.5 kVAR, 525 volts capacitor unit as specified - 1 Set Notes:All incoming and outgoing breakers shall be minimum 35 kA rating with Icu = Ics.Heavy duty exhaust fans to be provided for cooling Capacitors & Filters.LED indication for number of capacitor banks ‘ON’.LED indication of Power Factor lagging or leading.APFC system shall comprise of following:i. Over Voltageii. Voltage Imbalanceiii. Earth LeakageAll MCBs shall be minimum 10 kA breaking capacity.
700MDB-7 UPS Input Panel (Block A) Typical for (Block B) Incomer comprising of : 800 amps FP EDO ACB with Microprocessor based release for O/L, S/C & E/F proetction along with 800 Amps FP ATS - 1 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 800/5, 5 VA, CL 1, 3 No. CTs - 1 SetON / OFF / TRIP indicating lights with control MCB - 1 SetRYB Phase indicating light protected by 2 amps MCB’s - 1 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 1000 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 400 Amps TPN MCCB with Microprocessor based releases for SC, OL & EF protections etc. - 5 Set 63 Amps TPN MCCB with Microprocessor based releases for SC, OL & EF protections etc. - 2 Set Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.
701MDB-U1 UPS Output Panel (Block A) Typical for (Block B) Incomer comprising of : 400 amps FP MCCB with Microprocessor based release for O/L, S/C & E/F proetction - 3 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 400/5, 5 VA, CL 1, 3 No. CTs - 3 SetON / OFF / TRIP indicating lights with control MCB - 3 SetRYB Phase indicating light protected by 2 amps MCB’s - 3 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 1000 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 630 Amps FP MCCB with Microprocessor based releases for SC, OL & EF protections etc. - 2 Set 100 Amps FP MCCB with Thermalmagnetic based releases for SC, OL & EF protections etc. - 2 Set Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.
702MDB-U2 UPS Output Panel (Block A) Typical for (Block B) Incomer comprising of : 63 amps FP MCCB with Thermalmagnetic based release for O/L, & S/C proetction - 1 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 60/5, 5 VA, CL 1, 3 No. CTs - 1 SetON / OFF / TRIP indicating lights with control MCB - 1 SetRYB Phase indicating light protected by 2 amps MCB’s - 1 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 100 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 32 DP MCB, C Curve - 15 No. Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.All Outgoing breaker shall be provided with dual enerfy meter along with required CTs.
703MDB-1 Lighting Power panel(Basement) Incomer comprising of : 100 amps FP MCCB with Thermalmagnetic based release for O/L, & S/C proetction - 1 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 100/5, 5 VA, CL 1, 3 No. CTs - 1 SetON / OFF / TRIP indicating lights with control MCB - 1 SetRYB Phase indicating light protected by 2 amps MCB’s - 1 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 150 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 63 FP MCB, C Curve - 3 No. 40 FP MCB, C Curve - 5 No. 32 FP MCB, C Curve - 3 No. 32 DP MCB, C Curve - 5 No. Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.
704MDB-2 Basement Ventilation Panel Incomer comprising of : 160 amps FP MCCB with Thermalmagnetic based release for O/L, & S/C proetction - 2 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 160/5, 5 VA, CL 1, 3 No. CTs - 1 SetON / OFF / TRIP indicating lights with control MCB - 2 SetRYB Phase indicating light protected by 2 amps MCB’s - 2 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 63 FP MCB, C Curve - 11 No. Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.
705MDB-3 Lift Panel (Tower A) Typical for (Tower B) Incomer comprising of : 100 amps FP MCCB with Thermalmagnetic based release for O/L, & S/C proetction - 2 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 100/5, 5 VA, CL 1, 3 No. CTs - 1 SetON / OFF / TRIP indicating lights with control MCB - 2 SetRYB Phase indicating light protected by 2 amps MCB’s - 2 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 150 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 63 FP MCB, C Curve - 10 No. Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.
706MDB-5 Ventillation Panel (Tower A) Typical For (Tower B) Incomer comprising of : 100 amps FP MCCB with Thermalmagnetic based release for O/L, & S/C proetction - 1 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 100/5, 5 VA, CL 1, 3 No. CTs - 1 SetON / OFF / TRIP indicating lights with control MCB - 1 SetRYB Phase indicating light protected by 2 amps MCB’s - 1 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 150 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 63 FP MCB, C Curve - 12 No. Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.
707MDB-RM.1 Lighting & Power Panel (Tower A) Typical For All floor and (Tower B). Incomer comprising of : 160 amps FP MCCB with Thermalmagnetic based release for O/L, & S/C proetction along with 160 Amps 4 Pole ATS- 1 SetMultifunction meter for VAF, PF, Power & eneregy with RS - 485 port equivalent to Schneider make EM6436H with 160/5, 5 VA, CL 1, 3 No. CTs - 1 SetON / OFF / TRIP indicating lights with control MCB - 1 SetRYB Phase indicating light protected by 2 amps MCB’s - 1 Set.Class – B+C surge arrestor (Lines to Neutral) & (Neutral to Earth) suitable for 3 phases with protection fuse. Bus Bar comprising of : 200 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeves Outgoing comprising of : 100 Amps FP MCCB with Thermalmagnetic based releases for SC, OL & EF protections etc. - 6 Set 63 FP MCB, C Curve - 10 No. Notes:- All breakers MCCB shall be minimum 25 kA rating & MCB 10 kA with Icu = Ics.
708Feeder Pillar (For External Landscape lighting) IP 55 for outdoor Protection Incomer 63 Amps 4 pole MCB, Photocell Sensor Bus Bars100 Amps TPN Aluminium bus bars with heat shrinkable insulation sleeve. - 1 Set Outgoing 40 Amps 4 pole MCB incomer with 40 Amps TP contactor 0-24 hours timer auto / manual and outgoings including 10 No. 10/16/20 Amps SP MCB with 3 Nos. 32 Amps DP RCCB’s of 30 mA leakage current with separate neutral link of each phase- 1 set (50%) 40 Amps 4 pole MCB incomer with 40 Amps TP contactor 0-24 hours timer auto / manual and outgoings including 10 No. 10/16/20 Amps SP MCB with 3 Nos. 32 Amps DP RCCB’s of 30 mA leakage current with separate neutral link of each phase- 1 set (50%) 40 Amps DP MCB - 4 set 63 Amps 4 Pole MCB - 4 set
709RISING MAIN Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 1000A Capacity at 40oC ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,50KA short circuit rating for 1sec,Insulation Class F (155 C) , casing made of minimum 1.5mm hot / electro Galvanized /Epoxy powder coated steel sheet enclosure with required shade of paint having Mechanical strength certification up to IK10,overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories as per site requirement with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
710Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for 1000A 3 phase 4 wire 415V, 50 Hz A.C ,50kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories complete confirming to IEC 61439-6 as per specification
711Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 125A to 200A 3 phase 4 wire 415V, 50Hz AC Supply made with 1.5 mm thick sheet metal enclosure (IP54/55) duly powder coated with provision of MCCB( without MCCB) complete as required confirming to IEC 61439-6 as per specification
712DISTRIBUTION BOARD LT - MCBs/ MCB Change Over Switch (SW-MCB)Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
713Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
714Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
715Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
716LT - MCBDBs (SW-MCBDB) Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
717Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
718Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
719Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
720Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
721Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
722Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
7235 LT - MCCBs (SW-MCCB Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
724Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
725Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
726Providing & erecting 3 Pole MCCB 415V, 630A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
727RCCB / RCBO (SW-RCCB Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
728LT CABLE & CABLE TRAY Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
729Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
730Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
731Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
732Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
733Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
734Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
735Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
736Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
737Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
738Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
739Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
740Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
741Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
742Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
743Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 150 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU
744Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 25 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU
745Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
746Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
747Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.
748Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware
749Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
750Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware
751Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware
752EARTHING & LIGHTNING PROTECTION SYSTEM Earthing Sytem Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
753Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
754Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EAEP.
755Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.
756Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond with required joints. As per specification no. EA-EP.
757Concealing of Conduits Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
758Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
759Bunch of Wires Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
760Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
761Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
762Modular switches and Accessorie Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
763Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
764Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete.
765Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
766Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete
767Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete
768Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
769Point Wiring (WG-PW) Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
770Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW
771Point wiring for ceiling fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
772Wiring for plug on board with Switch socket surface/concealed type, copper wiring and eart
773Telephone, Audio and Video Wiring (WG-TW/TW)Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
774Supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW
775Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG 11 as per specification No. WG-TW
776Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG6 as per specification No. WG-T
777Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
778Telephone Accessories (WG-TW/TA)Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
779ELV Cabling (WG-COC Supplying and installing enhanced cat-6 LSZH cable with 4-connector channel Performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification.
780Supplying and erecting LSZH armoured multimode optical fibre cable with 12 fibres, core dia 50/125 µm (OM3), suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC
781Networking Components (WG- NWC) Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
782Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
783Networking Accessories (WG-NAS) Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
784Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patchpanel complete as per specification no. WG-NAS/KJ
785INTERNAL LIGHTING FIXTURES Indoor LED Fittings (FG-IDF/LED Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
786Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
787Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
788Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
789Supplying and erecting rectangular shaped LED Panel Light(1200mm X 300mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
790Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty.
791Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50 including driver with 1 year warranty.
792Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
793Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
794Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty
795Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty
796Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 x 20W UV Tube Lights to cover min. area of 500 sq.ft with powdered coated M.S./ steel body suitable to work on 230V, AC Supply having top mounting arrangement with SS chain complete and 3 core 1 mtr. flexible wire with 1 year warranty.
797Fans (FG-FN) Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD
798Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
799Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
800UPS Supplying, erecting, testing and commissioning of 3 x 200 kVA UPS, in Parallel Redundant configuration (N+1), online pure sine wave, with backup time of 0.3 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS (For Workstation - Builidng A & B)
801Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 1.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS (For Emergency Lighting)
802Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of 0.2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS (For Auditorium)
803Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS (For Auditorium : Emergency lighting)
804Supplying and erecting 12 V/100Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
805Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
806INFRASTRUCTURE FOR EXTERNAL LIGHTING SYSTEM Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixingaviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OH PL/HM (excluding luminaries)
807Providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
808Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
809Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
810Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
811Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
812Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 45 A TP C619contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete
813LIGHTING FIXTURE Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, C642CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
814Supplying and erecting integrated LED street light fitting 80-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
815Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
816Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
817Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FGODF/FLS2.
818Supplying and erecting integrated LED round burial light 6W IP65 & IK10 class having pressure die-cast housing, having system lumens output of Min. 500 Lumens, min. efficacy of 85 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 100-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50, including driver, salt spray tested for 500 Hrs. including making of recess of appropriate size for flushing into surface with 2 Year warranty as per specification No FG-ODF/FLS2.
819Supplying and erecting Concealed type foot/step light Max. 5W having IP67. IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, SDCM<5, p.f. >0.95, operating range of 230-270V, surge protection of 2.5 kV, Life class of 25,000 Hrs. at L70B50, including driver by making necessary arrangement/recess in wall to make it flush with surface with 2 Year warranty.
820ROOFTOP ON GRID SOLAR SYSTEM (ESD-RT-ONG) Supplying, installing, testing and commissioning of 100 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
821Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
822ELECTRIC VEHICLE CHARGER (ESD-EVC) Supplying, erecting, testing and commissioning of 30 kW DC Electric Vehicle Charger (suitable for 4 wheeler) having minimum IK08 & IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming supply and 1 nos 30kW output charger interface CCS2 with 200-500VDC supply, Interlocking arrangement with minimum 4 meter charging cable length, 5" LCD Touch Screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, One hour battery backup for communication, emergency push stop button. User interface by mobile application/QR Code/RIFD Card/Password Login with payment options and having short circuit, over & under voltage, input phase reversal, surge protection, earth leakage protection and enclosure made of minimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming to IS 17017 Series as per specification
823Providing yearly subscription of payment gateway option for AC/DC EV Charger CMS (Charger management software) system for billing and payment gateway along with mobile application /android/IOS base app to facilitate charging, CMS should have ISO/IEC 27001:2003 certification.
824FIRE ALARM SYSTEM Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
825Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
826Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
827Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF- FAS/SD.
828Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
829Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
830Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
831Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
832Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH
833Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP
834Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
835Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
836Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speaker complete as required.
837Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) Insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
838Supplying & fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
839Supplying, installation, testing & commissioning of 6 Zone voice alarm controller with USB, MP3, player (inlcuding 6 Zone button paging station) with seamless integration facility with Main Fire Alarm panel for voice evacuation complete as required.
840Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volts AC supply complete as required.
841Supplying, installation, testing & commissioning of Voice Command Keypad 6 zone, with microphone assembly complete as required.
842FIRE FIGHTING Supplying, installation, testing and commissioning of main fire pump(MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/E
843Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/ automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
844Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
845Supplying, erecting, testing & commissioning of fire pump control panel (FCP)of cubical construction, floor mounted type, fabricated from minimum 2 mmthick CRCA sheet, compartmentalised with hinged lockable doors, with enclosureprotection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connectionshaving switchgears and accessories, mountings and internal wiring with adequatesize copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automSupplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth
846The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps
847Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
848Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
849Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
850Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
851Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
852Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
853Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
854Supplying and erecting G.I. pipe ‘C’ class ERW 80 mm dia with necessary fittings complete as per specification no. FF-PP
855Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
856Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
857Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
858Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
859Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
860Providing coating of bitumen paint & 4mm thick wrapping for underground 200 mm ring main of fire fighting system.
861Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
862Supplying and erecting 80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
863Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
864Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
865Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
866Supplying and erecting 80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
867Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
868Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
869Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
870Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no.
871Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
872Supplying and erecting stainless steel double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
873Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
874Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF FFA/RRL
875Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/ NZ
876Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no.
877Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no.
878Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no.
879Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size(400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
880Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
881Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification
882Supplying, erecting, testing and commissioning vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
883Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
884Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no.
885S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
886Supplying and erecting DCP powder type fire extinguisher as per IS : 14609:1999 of 10 kg capacity with necessary clamp for erection on wall.
887Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 9 Lit capacity with necessary clamp for erection on wall.
888Supplying and erecting round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook.
889Supplying and erecting floor mounting stand for keeping 3 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 3 hooks and duly painted with one coat of red lead and two coats of silver paint.
890Supplying and erecting Sprinkler Alarm valve of 150 mm dia
891Supplying and erecting 80 mm dia. cast iron double flange butterfly valve with Tamper switch of size complete with PN16 pressure rating
892Supplying and erecting 100 mm dia. cast iron double flange butterfly valve with Tamper switch of size complete with PN16 pressure rating
893Supplying and erecting Control Cabling of Copper 4c x 2.5 sq mm cable in 25 mm dia PVC Conduit from Tamperswitch, vane Flow detector to sprinkler anunciation panel
894Supplying and erecting sprinkler anunciation panel pf 18 zones
895Supplying and erecting Fire Resistant Doors of Rating 2½ hours fire resistance of opening sizes 1200 W x 2100 H with Vision Window and panic Bar
896Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ- ACwith inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
897Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mmconforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
898Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF AFAS/SD .
899Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from-20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
900Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
901Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
902Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
903Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
904Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
905Supplying, installing, testing and commissioning of digital linear heat detection cable addressable through monitor module with temperature ratings such as 60° 70°C, conforming to IS 2189: 2008, EN 54 or UL listed FF-AFAS/LHDC.
906Supplying, erecting testing and commissioning beam smoke detector four wire single ended reflected type with 8 " receiver having digital display for easy alignment, adjustable sensitivity & heater kit for transmitter/receiver and reflector with necessary connections on suitable back box. The protection range of beam detector is 70 to 100 m.
907Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5- 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
908Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
909Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete
910ELV System CCTV SECURITY SYSTEM Supply, installation, testing and commissioning of indoor UL Listed IP N/W TDN Low-Light IR Dome Camera, 1/3"" CMOS sensor, 2 MP resolution @ 25fps or better, Fixed 2.8 mm lens, Auto Iris, Day Night cameras, Vandal Proof & Motion detection, POE, (high resolution cameras / 4CIF) ONVIF compliant complete with IP 66 Dome Housing, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment & all accessories.
911Supply, installation, testing and commissioning of indoor UL Listed IP N/W TDN Low-Light IR Bullet Camera, 1/3"" CMOS sensor, 2 MP resolution @ 25fps or better, varifocal 2.7 - 12 mm lens, Auto Iris, Day Night cameras, Vandal Proof & Motion detection, POE, (high resolution cameras / 4CIF) ONVIF compliant complete with IP 66 Dome Housing, Connectors, Lens, Camera Mounts, Power Supply, I/O and all Ancillary Equipment & all accessories.
912Supply, installation, testing and commissioning of Layer 3 managed switch with 24 ports (RJ-45), POE as to support all cameras 15% spare ports complete with supply. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, POE compliant ports, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/ LIUs/Convertors/Splicing equipment , Patch panel, Patch Cord Etc) complete as per specifications and as required.
913Supply, installation, testing and commissioning of Layer 2 managed switch with 24 ports (RJ-45), POE as to support all cameras 15% spare ports complete with supply. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, POE compliant ports, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/ LIUs/Convertors/Splicing equipment , Patch panel, Patch Cord Etc.) complete as per specifications and as required. Rack shall be included.
914Supply, installation, testing and commissioning of Layer 2 managed switch with 16 ports (RJ-45), POE as to support all cameras 15% spare ports complete with supply. The switch shall have 1 GB port to communicate with other switches including Passive components inbuilt 2 SFP ports including SFP modules, POE compliant ports, rack mountable, SMPS power supply & other termination accessories (Like Pigtails/ LIUs/Convertors/Splicing equipment , Patch panel, Patch Cord Etc.) complete as per specifications and as required. Rack shall be included.
915Supply installation Testing and Commissioning of Video Management Software and all Cameras shall be of same make for seamless Integration *web based client allows viewing and exporting video without installing any software and server client Architechture. *Imports users and roles from existing LDAP servers to reduce administrative overhead,and enables single sign-on (SSO)*Capable of listening for ASCII commands *Check on VMS and camera health using SNMP *Supports IPv4 and IPv6 cameras *Enables and supports Risk Management Framework (RMF),incorporates FIPS 140-3 validated cryptographic modules*TLS-based encryption over HTTPS*VMS Shall be able to Reduce Frame rate & FPS on recorded video to increase stoarge capacity * Bidder to consider liscences as per mentioned BOQ
916Supply, Installation, Testing & Commissioning of IP CCTV Monitoring, Recording & Streaming System: Control Room Equipments, support 128 channel, Intel® Xeon® Silver 4210, 16GB RAM, Windows 10 supported, RAID 5 support, OS 2x SSD 480 GB ( RAID 1), NVIDIA Quadro P620 (2 GB memory), 450Mbps, IPv4 and IPv6,2 x 1 Gigabit Ethernet (1000 Base-T), minimum 8 HDD Slots. For this Building bidder to consider enetrprise solution with client server architechture and 30 days storage at 2MP @ 25fps
917Supply, laying, connecting , testing and commissioning of VMS Server support windows 10 , i5 processor
918SITC of hard disk storage 12TB HDD surveillance grade
919Supply, installation, testing and commissioning of video management client workstations as required including 42" full HD LED 24x7 application, keyboard, Joystick, mouse, and all required accessories complete as per specifications and as required. The licence support shall be for life time. (Samsung/LG)
920Supply, laying, connecting , testing and commissioning of un-armoured 6C Single Mode Optic Fibre Communication Cable including required terminations, Junction Box, Connectors, LIU, SFP, Pigtails, Cable tie`s & Tags including MS conduit as per specification and as required.
921Network Wiring for Cameras/devices with CAT 6 cable from NVR in exposed / recessed 25 mm dia 16 gauge MS Conduit including termination and providing/fixing 1.2 mm thick GI box with grid plates with earthing complete in all respect.
922ACCESS CONTROL SYSETM Supply , installation, testing & commissioning of proximity card readers as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories
923Supply, installation, testing and commissioning of Finger print(Biometrics) readers with keypad suitable for mounting on metal surface / metal frames or wooden frames or wall or as required based on site conditions including all accessories.
924Supply, installation, testing and commissioning of proximity cards as per specification
925Supply , installation, testing and commissioning of Push Button for Exit
926Supply , installation, testing and commissioning of Two Door Controller for Controlling the above card readers with LAN onboard, TCP/IP interface as per specification mentioned including all accessories. (Tenderer to mention quantity of controllers based on their system.)
927Supply, installation, testing and commissioning of electromagnet door holder (fail safe type) of 15 lb holding force for the following doors : Single Leaf Door
928Double Leaf Door (Drop Bolt)
929Supply , installation, testing and commissioning of Door Contact
930Supply, installation, testing and commissioning of door open break glass switch for individual access control door. This shall be located in a powder coated lockable enclosure housed in control room. Quoted price shall be inclusive of wires running in 25 mm dia MS/GI conduit between door and this switch.
931Supply, installation, testing and commissioning of master switch for opening all access control door. Quoted price shall be inclusive of wire in 25 mm dia MS/GI conduit between doors and switch.
932Supply , laying , testing and commissioning of the following cables including 25mm MS conduits with all accessories 8 Conductor, 18-24 AWG, with sheild
933Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
934Supply and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same incase of recessed conduit as required. 25mm dia
935Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
936BMS Supplying, Installing, Testing & Commissioning of following BMS Machine: Intel i-7 (Latest Technology), Windows® 2010 SP2 or above operating System, 1 TB HDD, 8 GB RAM, Enhanced graphic Card, DVD Combo Drive, Ethernet Port with 32" color monitor flat screen LED display, multimedia keyboard & optical mouse and microsoft office 2013 and anti virus as per Specification.
937A4 B/W laser Printer
938Software:Web Based Graphical interface software. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, LON etc. Software should be scalable & no extra communication driver license required shall be acceptable. Software shall have 3 concurrent user license with upgradable to unlimited web user license
939SITC of Network Automation Server BTL/UL listed Required Gateway for integration of DDC controllers, third party services. Standard Open Protocols such as BACNet , MODBUS, Lonworks (optional) etc having memory of min 4 GB and Processor speed of min. 1.2 Ghz. Controller shall have battery backup for atleast 10 days. Gateway shall have 2 nos. 10/100 ethernet ports, 2 nos. RS-485 communication port. Gateways shall be DHCP enabled & have an option of creating whitelisting I/P for cybersecurity. Controller shall have provision of inbuilt web browser. Controller should support at least 4500 points. Chiller Plant, Secondary Pump VFD, Cooling Towers,Heat PumpsAir cooled heat pumps,AHU VFDs,Trivectormeter, DG Sets,Energy meters, FAS, Lifts and Escalators, Misc Integration Basement Ventilation PLC integration
940SITC of Standalone BTL & UL listed BACNet I/P field DDC controller having universal input/ output ports. Controller shall have 2 10/100 ethernet port & can communicate in Star, Daisy chain, RSTP topology & offer path redundancy for communication. DDC controller shall be DHCP enabled to ensure VPN network . All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics. The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules. Minimum on board IO points should not be less than 15 IO. DDC for HVAC Plant Room
941DDC for FM AHU (Without Heating Coil & with VFD) ( not more than 2 AHUs per DDC)
942DDC for FM AHU (With Heating Coil & with VFD) not more than 1 AHU per DDC
943DDC for CS AHU (WITH VFD ) (not more than 2 AHUs per DDC)
944DDC for CS AHU (WITHOUT VFD ) (not more than 2 AHUs per DDC)
945DDC for Treated Fresh Air Unit"s (With Coil); not more than 2 units per DDC
946DDC for Fan sections
947DDC for Smoke Exhaust/ Fresh Air Ventilation Fans and Pressurisation fans; not more than 4 fans per DDC
948DDC for Basement Ventillation not more than 4 fans per DDC
949DDC for AW and AS not more than 2 units per DDC
950DDC for UG/ OH Tank Level Monitoring
951DDC for STP Pumps
952DDC for Electrical System
953DDC for WTP Systems
954DDC for Hot/ Cold water Pumps (not more than 4 pumps per DDC)
955DDC for Air cooled heat pumps
956Field Devices SITC of Air DP Switch
957SITC of Duct T+Rh
958SIT of Duct Temp Sensor
959SITC of Bi-Level Switch
960SITC of Immersion Temp Sensor
961SITC of Voltage Transducer
962SITC of Flameproof Level Transmitter
963SITC of Flameproof Level Switch
964SITC of Air DP Sensor
965SITC of Water Level Transmitter
966SITC of Electromagnetic Flowmeter
967SITC of Current Relay
968SITC of CO2 Sensor
969Networking Devices & Accessories Supply, installation, testing and commissioning of Layer 2 unmanaged 10/100 switch. The switch shall have work with CAT6 armourded UTP cable within the building complete as per specifications and as required for BMS DDC Panel Networking. 16 Port Switch
970Cables & Cable Tray 2 x 1.5 sq.mm Annealed Tinned Copper, twisted pair, Shielded armoured cable for signal and power as per specification. (for I/O points hard wired to DDC).
971CAT 6 A unarmoured cables with required accessories like RJ45 connector etc.
9723 x 1.5 sq.mm Annealed Tinned Copper unarmoured cable for signal and power as per specification. (power Cable).
973HVAC WORK EQUIPMENT Supplying, installing, testing and commissioning of 50 mm thick double skin construction Air Handling Units comprising of following: (Floor Mounted ) Backward curved fan inside double skin housing with efficiency not less than 75% Pre filter (MERV 8) and Fine filter (MERV-13) in supply air stream. All AHU with 4/6 row deep cooling coil unless specified otherwise. SS 304 construction end plates to be provided. TEFC Motors suitable for 415 ± 10% volts, 50 Hz, AC supply and IE 3 efficiency. The maximum rating is specified below and contractor can select a lower rating motor incase the desired performance is being met. Motor shall be suitable to operate on VFD. Fan belt drive package Fan outlet velocity not exceeding 10 mps. Hydrophilic coating shall be carried out on the chilled water coil and hot water coil. All the AHU"s shall be provided with UVGI shining at Chilled water Coil Minimum 20-25 mm (WC) external static pressure shall be considered. However, actual total static pressure shall be calculated and confirmed by the vendor at the time of bidding. AHU"s shall be provided with mixing box with thermal break profile AHU"s placed in open shall be provided with a rain water canopy and all the terminal connection shall be enclosed by IP 64 Rating The desired rating of AHU shall be as follows: AHU Tag Area of Operation CFM Cooling Coil (TR) Heating Coil (kW) Recommended mini motor (kW) Mixing Box Ground Floor AHU 1&2 Audi double height 12000 30 - 7.5 NO
974Supplying, installing, testing and commissioning of 50mm thick double skin construction Air Handling Units comprising of following: (Ceiling Mounted) Forward curved fan mounted inside double skin housing with efficiency not less than 60% Pre filter (MERV 8) in supply air stream. All AHU with 4/6 row deep cooling coil unless specified otherwise. SS 304 construction end plates to be provided. All the AHU"s shall be provided with UVGI shining at Chilled water Coil TEFC Motors suitable for 415 ± 10% volts, 50 Hz, AC supply and IE 3 efficiency. The maximum rating is specified below and contractor can select a lower rating motor incase the desired performance is being met. Motor shall be suitable to operate on VFD. Fan belt drive package. Fan outlet velocity not exceeding 10 mps. Hydrophilic coating shall be carried out on the chilled water coil & hot water coil All AHU are ceiling suspended type complete with mixing box, vibration isolation & hanging arrangement with height of unit not exceeding 700 mm. Minimum 15-20 mm (WC) external static pressure shall be considered. However, actual total static pressure shall be calculated and confirmed by the vendor at the time of bidding. The desired rating of AHU shall be as follows: AHU Tag Area of Operation CFM Cooling Coil (TR) Heating Coil (kW) Recommended mini motor (kW) Mixing Box Ground Floor CAHU 1 Lobby tower A 4500 12 ---- 2.2 No
975CAHU 2 Lobby tower B 4500 12 ---- 2.2 No
976CAHU 3 &4 Office LHS 3500 9 ---- 2.2 No
977CAHU 5&6 Office RHS 3500 9 2.2 No
978Mazzanine Floor CAHU 7 Office LHS 1000 3 --- 1.1 No
979CAHU 8 Office LHS 5000 13 ---- 2.2 No
980CAHU 9 Office RHS 1000 3 ---- 1.1 No
981CAHU 10 Office RHS 5000 13 ---- 2.2 No
982First Floor CAHU 11 to 13 Audi 300 Pax 5000 13 ---- 2.2 No
983CAHU 14 Café 4500 12 ---- 2.2 No
984CAHU 15 Lobby LHS 3500 10 ---- 2.2 No
985CAHU 16 Office LHS 1 2000 5 ---- 1.1 No
986CAHU 17 Office LHS 2 3500 10 ---- 2.2 No
987CAHU 18 Office LHS 3 3000 8 ---- 2.2 No
988CAHU 19 Office LHS 4 4500 12 ---- 2.2 No
989CAHU 20 Lobby RHS 2000 5 ---- 1.1 No
990CAHU 21 Office RHS 1 3500 10 ---- 2.2 No
991CAHU 22 Office RHS 2 2000 5 ---- 1.1 No
992CAHU 23 Office RHS 3 4500 12 ---- 2.2 No
993CAHU 24 Office RHS 4 3500 10 ---- 2.2 No
994Second Floor CAHU 25 Lobby LHS 2000 5 ---- 1.1 No
995CAHU 26 Office LHS 1 2500 6 ---- 1.1 No
996CAHU 27 Office LHS 2 3500 13 ---- 2.2 No
997CAHU 28 Office LHS 3 3000 8 ---- 2.2 No
998CAHU 29 Office LHS 4 4500 12 ---- 2.2 No
999CAHU 30 Lobby RHS 2000 5 ---- 1.1 No
1000CAHU 31 Office RHS 1 3500 10 ---- 2.2 No
1001CAHU 32 Office RHS 2 2000 5 ---- 1.2 No
1002CAHU 33 Office RHS 3 4500 12 ---- 2.2 No
1003CAHU 34 Office RHS 4 3500 10 ---- 2.2 No
1004CAHU 35 Meeting Room-1 3500 10 ---- 2.2 No
1005CAHU 36 Meeting Room-2 3500 10 ---- 2.2 No
1006Third Floor CAHU 37 Lobby LHS 2000 5 ---- 1.1 No
1007CAHU 38 Office LHS 1 2500 6 ---- 1.1 No
1008CAHU 39 Office LHS 2 35000 10 ---- 2.2 No
1009CAHU 40 Office LHS 3 3000 8 ---- 2.2 No
1010CAHU 41 Office LHS 4 4500 12 ---- 2.2 No
1011CAHU 42 Lobby RHS 2000 5 ---- 1.1 No
1012CAHU 43 Office RHS 1 3500 10 ---- 2.2 No
1013CAHU 44 Office RHS 2 2000 5 ---- 1.1 No
1014CAHU 45 Office RHS 3 4500 12 ---- 2.2 No
1015CAHU 46 Office RHS 4 3500 10 ---- 2.2 No
1016CAHU 47 Meeting Room-1 3500 10 ---- 2.2 No
1017CAHU 48 Meeting Room-2 3500 10 ---- 2.2 No
1018Fourth Floor CAHU 49 Lobby LHS 2000 5 ---- 1.1 No
1019CAHU 50 Office LHS 1 2500 6 ---- 1.1 No
1020CAHU 51 Office LHS 2 3500 10 ---- 2.2 No
1021CAHU 52 Office LHS 3 3000 8 ---- 2.2 No
1022CAHU 53 Office LHS 4 4500 12 ---- 2.2 No
1023CAHU 54 Lobby RHS 2000 5 ---- 1.1 No
1024CAHU 55 Office RHS 1 3500 10 ---- 2.2 No
1025CAHU 56 Office RHS 2 2000 5 ---- 1.1 No
1026CAHU 57 Office RHS 3 4500 12 ---- 2.2 No
1027CAHU 58 Office RHS 4 3500 10 ---- 2.2 No
1028Fifth Floor CAHU 59 Lobby LHS 2000 5 ---- 1.1 No
1029CAHU 60 Office LHS 1 2500 6 ---- 1.1 No
1030CAHU 61 Office LHS 2 3500 10 ---- 2.2 No
1031CAHU 62 Office LHS 3 3000 8 ---- 2.2 No
1032CAHU 63 Office LHS 4 4500 12 ---- 2.2 No
1033CAHU 64 Lobby RHS 2000 5 ---- 1.1 No
1034CAHU 65 Office RHS 1 3500 10 ---- 2.2 No
1035CAHU 66 Office RHS 2 2000 5 ---- 1.1 No
1036CAHU 67 Office RHS 3 4500 12 ---- 2.2 No
1037CAHU 68 Office RHS 4 3500 10 ---- 2.2 No
1038Sixth Floor CAHU 69 Lobby LHS 2000 5 ---- 1.1 No
1039CAHU 70 Office LHS 1 2500 6 ---- 1.1 No
1040CAHU 71 Office LHS 2 3500 10 ---- 2.2 No
1041CAHU 72 Office LHS 3 3000 8 ---- 2.2 No
1042CAHU 73 Office LHS 4 4500 12 ---- 2.2 No
1043CAHU 74 Lobby RHS 2000 5 ---- 1.1 No
1044CAHU 75 Office RHS 1 3500 10 ---- 2.2 No
1045CAHU 76 Office RHS 2 2000 5 ---- 1.1 No
1046CAHU 77 Office RHS 3 4500 12 ---- 2.2 No
1047CAHU 78 Office RHS 4 3500 10 ---- 2.2 No
1048CAHU 79 Meeting Room-1 5000 13 ---- 2.2 No
1049CAHU 80 Meeting Room-2 5000 13 ---- 2.2 No
1050Seventh Floor CAHU 81 Lobby LHS 2000 5 ---- 1.1 No
1051CAHU 82 Office LHS 1 2500 6 ---- 1.1 No
1052CAHU 83 Office LHS 2 3500 10 ---- 2.2 No
1053CAHU 84 Office LHS 3 3000 8 ---- 2.2 No
1054CAHU 85 Office LHS 4 4500 12 ---- 2.2 No
1055CAHU 86 Lobby RHS 2000 5 ---- 1.1 No
1056CAHU 87 Office RHS 1 3500 10 ---- 2.2 No
1057CAHU 88 Office RHS 2 2000 5 ---- 1.1 No
1058CAHU 89 Office RHS 3 4500 12 ---- 2.2 No
1059CAHU 90 Office RHS 4 3500 10 ---- 2.2 No
1060CAHU 91 Meeting Room-1 5000 13 ---- 2.2 No
1061CAHU 92 Meeting Room-2 5000 13 ---- 2.2 No
1062Eight Floor CAHU 93 Lobby LHS 2000 5 ---- 1.1 No
1063CAHU 94 Office LHS 1 2500 6 ---- 1.1 No
1064CAHU 95 Office LHS 2 3500 10 ---- 2.2 No
1065CAHU 96 Office LHS 3 3000 8 ---- 2.2 No
1066CAHU 97 Office LHS 4 4500 12 ---- 2.2 No
1067CAHU 98 Lobby RHS 2000 5 ---- 1.1 No
1068CAHU 99 Office RHS 1 3500 10 ---- 2.2 No
1069CAHU 100 Office RHS 2 2000 5 ---- 1.1 No
1070CAHU 101 Office RHS 3 4500 12 ---- 2.2 No
1071CAHU 102 Office RHS 4 3500 10 ---- 2.2 No
1072Ninth Floor CAHU 103 Lobby LHS 2000 5 ---- 1.1 No
1073CAHU 104 Office LHS 1 2500 6 ---- 1.1 No
1074CAHU 105 Office LHS 2 3500 10 ---- 2.2 No
1075CAHU 106 Office LHS 3 3000 8 ---- 2.2 No
1076CAHU 107 Office LHS 4 4500 12 ---- 2.2 No
1077CAHU 108 Lobby RHS 2000 5 ---- 1.1 No
1078CAHU 109 Office RHS 1 3500 10 ---- 2.2 No
1079CAHU 110 Office RHS 2 2000 5 ---- 1.1 No
1080CAHU 111 Office RHS 3 4500 12 ---- 2.2 No
1081CAHU 112 Office RHS 4 3500 10 ---- 2.2 No
1082Tenth Floor CAHU 113 Lobby LHS 2000 5 ---- 1.1 No
1083CAHU 114 Resident Dty Collector -1 45000 12 ---- 2.2 No
1084CAHU 115 Resident Dty Collector -2 2500 6 ---- 1.1 No
1085CAHU 116 Spare Office RHS-1 4500 12 ---- 2.2 No
1086CAHU 117 Spare Office RHS-2 2500 6 ---- 1.1 No
1087CAHU 118 Lobby RHS 2000 5 ---- 1.1 No
1088Eleventh Floor CAHU 119 Lobby LHS 2000 5 ---- 1.1 No
1089CAHU 120 Add Collector Office 4500 12 ---- 2.2 No
1090CAHU 121 Collector Office 2500 6 ---- 1.1 No
1091CAHU 122 Spare Office RHS-1 4500 12 ---- 2.2 No
1092CAHU 123 Division Office 2500 6 ---- 1.1 No
1093CAHU 124 Lobby RHS 2000 5 ---- 1.1 No
1094Supplying, installing, testing and commissioning of Chilled Water based Wall Mounted Hi Wall Water type Eurovent/ AHRI certified Units with Single Phase 3 speed motor, filter section with prefilters 70% down to 20 micron, Coil section with 2 Row and minimum 13 FPI Chilled Water Cooling Coil, Unit shall be supplied with 230V operating / Power On / Off provision, 3 speed fan switch & Temp Edit facility / Digital Temp Display), a factory fitted valve station (comprising of 2 No. Ball valve, Y Strainers with drain cock, modulating type two way pressure independent dynamic control & balancing valve with spring return feature, Set of flexible connectors mini 500mm long. Kit should have minimum 3 Years of warranty), and supplied with 10 RMT cable from Controller to unit as required. Units shall be self-diagnostic type with relevant safety interlocks. All additional items required for such modulating actuator functionality shall be part of this scope. 1.0 TR refrigeration capacity
1095Supply, installation, testing and commissioning of double skin constrction Dedicated outdoor air system (DOAS) Supply air Section Pre filter (MERV 8) washable type, Fine Filter (MERV 14). Filters shall be UL certified for fire rating. Filters shall be sized for air velocity of 500 fpm. Plug Fan with efficiency >75%. (2 No. fans of equal capacity to be provided). From electrical panel there shall be single input to Single AHU terminal box. All necessary internal wiring from Terminal Box to multiple direct drive motors provided by AHU vendor .TEFC Motors suitable for 415 ± 10% volts, 50 Hz, AC supply and IE 2 efficiency. The maximum rating is specified below and contractor can select a lower rating motor incase the desired performance is being met. Enthalpy wheel for heat recovery placed between outdoor air and exhaust air streams with total effficiency >75%. The DOAS shall be designed for receiving exhaust air temperature of 77 F DBT & 60% RH during summer & monsoon conditions. For ambient air conditions, refer Design basis in tender specifications.8 row deep cooling coil sized for air velocity of 500 fpm, SS 304 construction end plates to be provided UV lamp Shining at the Coil Return air SectionPre filter (MERV 8) in return air stream and sized for air velocity of 500 fpm. Plug Fan with efficiency >75%. (2 No. fans of equal capacity to be provided) From electrical panel there shall be single input to Single AHU terminal box. All necessary internal wiring from Terminal Box to multiple direct drive motors provided by AHU vendor . TEFC Motors suitable for 415 ± 10% volts, 50 Hz, AC supply and IE 2 efficiency. The maximum rating is specified below and contractor can select a lower rating motor incase the desired performance is being met. Minimum 30 mm (WC) external static pressure shall be considered. However, actual total static pressure shall be calculated and confirmed by the vendor at the time of bidding.The rating shall be as follows:Equipment Tag Space Location TR SA CFM/ RA CFM Motor KW (SA/ EA) Supply ReturnDOAS-01&2 G.F To 11th Floor Terrace 40 10500 / 7600 1 No. 3.2 kW 1 No. 5.5 kW
1096Supplying, installing, testing and commissioning of Smoke extraction Axial fans as per specifications. Fan shall be with direct driven Tube axial fan. The fan shall be equipped with mounting bracket, fire rated flexible connection. Cost of spring isolators for the installation of the fans needs to be included. The motor shall be Class H rating and suitable for 415±10% volts 3 phase 50 cycles, AC supply. The motor selected shall be IE3 efficiency at full load. Fan shall be selected for minimum efficiency of 65%. Fan and casing shall be suitable for normal & smoke exhaust application.Motor shall be mounted inside the fan casing & thermally rated for 250 Deg C for 2 hour as per [BS-7346 Part-2 : 1090] External static pressure shall be 15-20 mm (WC) minimum and Total static pressure shall be checked by vendor. All fans mentioned are used in case of fire and can be selected for higher outlet velocity as sound is not criteria while selecting.The fan capacities shall be as follows:Equipment Tag Space Location CFM Motor kWAXF 1 Parking Zone-1 Basement 40000 10
1097AXF 2 Parking Zone-2 Basement 40000 10
1098AXF 3 PHE plant room Basement 10000 3.3
1099AXF 4 STP Plant Room Basement 23000 5.5
1100AXF 5 Mazzanine Mazzanine 7500 3.2
1101AXF 6 1st to 11th floor Terrace level 15000 5Note- Fans used incase for fire can be IE2 motor based and noise shall not be a criteria while selecting the fan
1102Supply, installation, testing & commissioning of Axial Flow Fans suitable for installing in both Horizontal or vertical position as per site requirement and complete with totally enclosed fan cooled, direct drive set, motor mount, fire rated flexible connection and vibration isolators. The fan shall be equipped with mounting bracket. Fan shall be selected for minimum efficiency of 65%. All fans mentioned are used in case of fire and can be selected for higher outlet velocity as sound is not criteria while selecting. The motor shall be suitable for 415±10% volts 3 phase 50 cycles, AC supply. The motor selected shall be IE 3 efficiency . External static pressure shall be 20-25 mm (WC) minimum and Total static pressure shall be checked by vendor. The fan capacities shall be as follows:Equipment Tag Space Location CFM Motor kWSA-1 PHE plant room Basement 10000 3.3
1103SA-2 STP Plant Room Basement 23000 5.5
1104SA-3 Mazzanine Mazzanine 7500 3.2
1105SA-4 1st to 11th floor Terrace level 15000 5
1106SA-5 Lift well Pressurization Terrace level 18000 5.5
1107SA-6 Staircase Pressurization Terrace level 20000 5.5
1108SA-7 Lift lobbyl Pressurization Terrace level 25000 5.5Note- Fans used incase for fire can be IE2 motor based and noise shall not be a criteria while selecting the fan
1109Supply, Installation, Testing and Commissioning of Scrubber each comprising of extract air intake section, electrostatic precipitation technology, dry type air cleaner to remove oil, smoke and fumes from exhaust air, as per the Specifications : The unit shall be integrated & connected with centrifugal fan for kitchen including all necessary accessories to complete the installation. Supply, Installation, Testing and Commissioning of Kitchen ventilation system comprising of following items : SISW class I backward curved centrifugal fans for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor, belt drive, pulley mounted on motor (IE3) & fan shaft, belt guard, motor mount and vibration isolators. The motor shall be suitable for 415±10% volts 3 phase 50 cycles, AC supply. The motor selected shall be energy efficient having efficiency at full load ranging between 82.5% to 92% in accordance with motor rating as per specification. External static pressure shall be 25-30 mm (WC) minimum and Total static pressure shall be check by vendor. Fan capacities shall be as follows: Equipment Tag Space Equipment Location CFM Motor kW Dry Scrubber unit Kitchen Basement-1 8000 7.5 kw
1110Supplying, installing, testing and commissioning of double skin construction Fan sections (made out of 25mm thick panel) complete with internally mounted motor, fan belt drive, flexible connection, vibrations isolators and complete with following: TEFC Motors suitable for 415 ± 10% volts, 50 Hz, AC supply and IE 3 efficiency. The maximum rating is specified below and contractor can select a lower rating motor incase the desired performance is being met. Forward curved fan inside double skin housing with efficiency not less than 75%. Minimum 15-20 mm (WC) external static pressure shall be considered. However, actual total static pressure shall be calculated and confirmed by the vendor at the time of bidding. Height of the unit shall not exceed 550mm, contractor to select the no. of fans accordingly. Fan shall be provided with pre filters of MERV-8. FA : Fresh air fan , EA : Exhaust air fan The rating of fan sections shall be as follows: Fan Tag Location CFM SP (mmwg) Motor kW EA 01 Kitchen 5000 20-25 3.3
1111Supplying, installing, testing and commissioning of SILENT MIXED FLOW INLINE FANS suitable for installing in any position in vertical or horizontal ducts.Constructed with sheet steel with epoxy polyester paint, acoustic isulation within the outer shell. Two speed motor (IP 44 Rated) with removable fan body with two speed motor, single phase speed controlable class F external rotor motor with capacitor and thermal protection. All units shall be complete with duct flexible connector, speed regulator (with wiring of 3 m included between fan & regulator) and volume control damper and static pressure or to suit the system, shall be as follows: The sound level shall be mesured at three metre distance. Actual static to be checked by the vendor during the shop drawingsCFM Noise Level (dB)A SP MMWGUpto 100 21-30 10--15
1112801-1000 35-40 15--20
1113Supply, installing, testing and commissioning of VFD suitable for HVAC application with minimum IP 20 enclosures complying with the tender specifications and shall be complete in all respects and suitable for following motor rating and shall meet the following specifications : a) The VFD shall have a dual 5% impedance DC link reactor (Harmonic filters) on the positive and negative rails of the DC bus to minimize power line harmonics and protect the VFD from power line transients. The chokes shall be non-saturating.b) All the VFD’s should have factory fitted IP20 enclosure protection c) EMC filters, C1 Category, Drive should support at least 3 PID loops are requiredd) Panel space and wiring shall be included under Electrical Panel sectione) Pressure sensor and wiring shall be included in the cost.All FM AHU, Parking / Plant room fansMotor HP 10
1114Motor HP 7.5
1115Motor HP 5
1116Motor HP 3
1117Motor HP 2
1118Supply, installing, testing and commissioning of Adequate number of CO sensors,PLC with power / control cabling for car park ventilation fans at basement and logic controller with necessary control cabling will form a part of the same. Please note that VFD, Fan is considered in separate item of the BOQ. Electrical starter panel shall be provided by main electrical contractor.
1119PIPING- CHILLED WATER INSULATED CHILLED Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excludingvalves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class "O" insulation applied by suitable adhesivecomplete including repairing of damage to building etc. as per specifications and as required complete in all respect.Note:- The Pipes of sizes 150mm & below shall be M.S. "C" class asper IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S.Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 300 mm dia (32 MM Thick Insulation)
1120250 mm dia (32 MM Thick Insulation)
1121200 mm dia (32 MM Thick Insulation)
1122150 mm dia (32 MM Thick Insulation)
1123125 mm dia (32 MM Thick Insulation)
1124100 mm dia (32 MM Thick Insulation)
112580 mm dia (32 MM Thick Insulation)
112665 mm dia (32 MM Thick Insulation)
112750 mm dia (32 MM Thick Insulation)
112840 mm dia (32 MM Thick Insulation)
112932 mm dia (19 MM Thick Insulation)
113025 mm dia (19 MM Thick Insulation)
113120 mm dia (19 MM Thick Insulation)
1132BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified 300 mm dia
1133250 mm dia
1134200 mm dia
1135150 mm dia
1136125 mm dia
1137100 mm dia
113880 mm dia
113965 mm dia
114050 mm dia
114140 mm dia
114232 mm dia
114325 mm dia
1144Supplying, installing and fixing in position Motorised butterfly valves of PN 16 rating and suitable for following pipe sizes. Price shall include the cost of Insulation, material and external treatment will be same as of pipe : 200 mm dia
1145Supply,Installation Testing and Commissioning of Flexible Pipe Connection (Double Arch PN 16 rating) at pumps/chiller suction and discharge (Material of Construction-EPDM Rubber ) with integral rubber flanges with SRR & control unit suitable for operation between Temperature rage: - 10 to 90 degree celcius. 200 mm dia Insulated
1146Supplying, installing, testing and commissioning of insulated Triple duty valve for the following water pumps described below. Price shall include the cost of Insulation, material and external treatment will be same as of pipe 200 mm dia Insulated
1147BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 250 mm dia
1148200 mm dia
1149150 mm dia
1150125 mm dia
1151100 mm dia
115280 mm dia
115365 mm dia
115450 mm dia
115540 mm dia
115632 mm dia
115725 mm dia
1158Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 65 mm dia
115950 mm dia
116040 mm dia
116132 mm dia
1162Supply installation, testing & commissioning of Two Way high rangaeability/ pressure independent dynamic balancing cum control valve fitted with motorized, modulating actuators with linear stroke of minimum 15mm, in chilled water lines at each air handling unit, the actuator shall have shut off capability of minimum 4 Bar rating. the actuator shall be controlled by building automation system & should accept a signal of 4-20mA/2-10 VDC. The valve shall be suitable for following flow rates & conforming to specification. The digital electronic controller with LCD display capable of accepting 0-10V DC signal from BMS & Water Temperature signals from the coil inlet & outlet sensors conforming to detailed specifications. all other accessories i.e Sensors-3 No. 230V/24VAC power Supply 1 No. thermowell-1 No. should be included in this item. 80 mm dia
116350 mm dia
116440 mm dia
116532 mm dia
1166Supplying, installing and fixing in position ball valves of PN 16 rating and suitable for following pipe sizes. Price shall include the cost of Insulation, material and external treatment will be same as of pipe: 32 mm dia
116725 mm dia
1168Supply, installation, testing and commissioning of cooling/Heating thermostats for various Air Handling Units and Fan Coil Units as per specifications including all accessaries ,mountings,wiring between thermostat & unit, terminations etc.(BMS Compatibility to be provided). Proportional thermostats for Cooling only AHU
1169Supply, installation, testing and commissioning of Auto Purge Valves of brass construction with screwed ends duly insulated as per specifications and drawings complete in all respect. 25 mm dia
1170Providing and fixing in position the industrial type pressure gauges with gun metal/brass valves complete as required. (150mm dia)
1171Providing & fixing in position the mercury in glass industrial type thermometer complete as required. (150mm dia)
1172Supply, installation, testing and commissioning of Fully Insulated FCU kit comprising of 3 No. Ball valve, Y Strainers with drain cock, 2- Way On/Off valve , Set of flexible connectors mini 500mm long. Valve suitable for 25 mm dia pipes
1173Supplying and fixing GI class ‘B’ pipes cut to required lengths and complete with threaded joints. Quoted price shall include providing and fixing in position fittings, elbows, tees, reducers, expanders, mating flanges & sockets for Building Automation System as required.. The pipes shall be of following sizes: Pipe shall have 25 mm thick pre-moulded pipe section of T.F. quality expanded polystyrene (24 Kg / M3 density) insulation on chilled water and condensate drain piping/fittings includng valves, flanges, union etc. as per the approved shop drawings and specifications. Insulated GI pipes of 40 mm dia
1174Insulated GI pipes of 32 mm dia
1175Insulated GI pipes of 25 mm dia
1176Insulated GI pipes of 20 mm dia
1177PIPING- CONDENSOR WATER (UNINSULATED) Supply, Installation, Testing and comissioning of MS Pipe class "C" heavy confirming to IS:1239/3589 including all accessories such as screw joint, flange, tee, groove couple, reducer, Adapters, rubber gaskets, flexible coupling, GI nuts bolts, washer including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) as per specification. As required pipe shall be painted with two coats of primer and two coats of post office red synthetic enamel paint over two coats of red oxide zinc chromate primer. Surface to be cleaned prior to priming. MS pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls/floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per Engineer requirements including cutting holes and chases in brick, R.C.C work. All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwire and then supply of the same shall also be included for rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted. 350 mm dia MS Pipes
1178300 mm dia MS Pipes
1179250 mm dia MS Pipes
1180200 mm dia MS Pipes
118165 mm dia. MS Pipe
118250 mm dia. MS Pipe
1183Supplying, installing and fixing in position Motorised butterfly valves of PN 16 rating and suitable for following pipe sizes. Price shall include the cost of Insulation, material and external treatment will be same as of pipe : Valves of 200 mm dia
1184BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating as specified. 350 mm dia
1185200 mm dia
1186100 mm dia
1187Supply,Installation Testing and Commissioning of Flexible Pipe Connection (Double Arch PN 16 rating) at pumps/chiller suction and discharge (Material of Construction-EPDM Rubber ) with integral rubber flanges with SRR & control unit suitable for operation between Temperature rage: - 10 to 90 degree celcius. 200mm dia
1188Supplying, installing, testing and commissioning of insulated Triple duty valve for the following water pumps described below. Price shall include the cost of material and external treatment will be same as of pipe 200mm dia ( Un-Insulated)
1189Providing and fixing in position the industrial type pressure gauges with gun metal/brass valves complete as required. (150mm dia)
1190Providing & fixing in position the mercury in glass industrial type thermometer complete as required. (150mm dia)
1191BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating cond. water circulation as specified. (w/o insulation) 250 mm dia
1192200 mm dia
1193AIR DISTRIBUTION (FOR AIR CONDITIONING AREAS)Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. (It shall be as per SMACNA standards)Note:- UV coating & Mechanical protection shall be considered for exposed ducting insulation.GSS Duct with Soldereing shall be provided for Critical area having 0.3 micron Filter in AHU. (duct support via gripple) Duct Size 0 -1200 mm Recommended Gauge of GI sheet24
11941201 -1800 mm Recommended Gauge of GI sheet22
11951801 - 2100 mm Recommended Gauge of GI sheet 20
11962101 - above Recommended Gauge of GI sheet 18
1197Supply, installation, balancing and commissioning fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.(It shall be as per BIS standards).Note:- UV coating & Mechanical protection shall be considered for exposed ducting insulation. Thickness 0.63 mm sheet
1198Thickness 0.80 mm sheet
1199Thickness 1.00 mm sheet
1200Thickness 1.25 mm sheet
1201Supply, installation, testing and commissioning of GI volume control duct damper (18 gauge) complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
1202Supply, fabrication, installation and testing the flexible Canvas constructed of fire resistant double resin sleeve as per the specifications.
1203Supplying, fixing, testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
1204Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
1205Supply, installation and balancing of Extruded Aluminium construction Supply air Grilles with volume control dampers. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications.
1206Supply, installation and balancing of Extruded Aluminium construction Return air Grilles without volume control dampers. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications.
1207Supply, installation, testing and balancing of powder coated /Anodised extruded aluminium construction louvers with bird screen for Fresh air as per specifications.
1208Supply, installation, testing and balancing of powder coated /Anodised extruded aluminium construction louvers without bird screen for exhaust air as per specifications.
1209Supply, installation, testing and commissioning of motorised(ON/OFF Type) duct mounted opposed blade G.I volume control damper with enthalpy sensor and necessary control wiring (minimum 1.5 sqmm ) for integeration within IDU room.The unit shall provided as shown in the drawings. The unit shall be capable to communicate with BMS system. Fire damper
1210Actuator (Rated torque-10 N.m/m2) wit 20 rmt control witing in PVC conduit
1211Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire damper
1212Actuator
1213Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction Door Transfer Grille for make up/exhaust air. The grilles will be powder coated in shade approved by Client and installed as per approved shop drawings and specifications.
1214THERMAL INSULATION Supply and installation of external thermal insulation on ducts. closed cell Nitrile rubber (class “O”) insulation duly laminated with 241is patch foil (Aluminum). with thermal conductivity not exceeding 0.032 W/moK at an average temperature of 250 C. Density of the material shall be 25-30 Kg/m3 and shall be single layer up to 18mm thickness. The insulation material shall be fire rated for Class O as per BS-476 Part 7 with non-toxic smoke. Quoted price shall be inclusive of adhesive, tapes as per specification. 19 mm thick- For Supply Duct
121513 mm thick- For Return Duct
121625mm thick woith UV coat
1217Supplying, installation, testing & commissioning of acoustic lining within supply and return air ducts as per the specifications. All ducts shown cross hatched on the approved shop drawings shall be provided with acoustic lining of Open Cell Engineered Nitrile Rubber foam (Antimicrobial) tested as per ISO 354:2003, ISO 11654:1997 & ASTM C 423. 140-180 kg/cum for AHU rooms/DG room/Duct . It should be complete in all respect & as per directions of engineer-in-charge. 15 mm thick acoustic lining for duct
121825 mm thick acoustic lining for AHU Room (only on internal hospital facing wall)
1219ELECTRICAL INSTALLATION CONTROL PANELS FOR AHU"s Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels including anchoring into the wall, wiring, incoming, earthing & terminating into MCCB in each panel shall be provided by the electrical contractor. Space in Panel for mounting the VFD shall be provided. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contact for Connections to Building Automation System. The panel shall include the following components & accessories. a. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. b. DOL/SD starter as HP ratingc. Terminal block for power distribution as required. d. Contactor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for ON status. f. Digital voltmeter and digital ammeter. g. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. h. 3 No. of Single Pole MCB"s Shall be provided at the incoming section of the starter panel for DDC Panel , fire damper actuator & as a spare. i. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. l. 220 / 24 V Transformer The number of control panels shall be as follows. Suitable rating MPCB with DOL starter for upto 5.0 HP motor (VFD)
1220Suitable rating MPCB with S/D starter for upto 7.5 HP motor (VFD)
1221CONTROL PANELS FOR FANS Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall mounted control panels, including anchoring into the wall, wiring terminating into MCCB and copper earthing, in each panel shall be provided by the electrical contractor. Space in Panel for mounting the VFD shall be provided. All outgoing shall be provided with Stop /Manual /Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contact for Connections to Building Automation System. The panel shall include the following components & accessories.a. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA. b. DOL/SD starter as HP rating c. Terminal block for power distribution as required. d. Contactor, over load relay with built in single phasing protection. e. Phase indicating lights and indicating light for ON status. f. Digital voltmeter and digital ammeter. g. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation h. 3 No. of Single Pole MCB"s Shall be provided at the incoming section of the starter panel for DDC Panel , fire damper actuator & as a spare. i. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. j. 220 / 24 V Transformer The number of control panels shall be as follows.Suitable rating MPCB with DOL starter for upto 5.0 HP motor (VFD)
1222Suitable rating MCCB with DOL starter for upto 5.0 HP motor (Non-VFD)
1223Suitable rating MPCB with S/D starter for upto 7.5 HP motor (VFD)
1224Suitable rating MCCB with S/D starter for upto 7.5 HP motor (Non-VFD)
1225Suitable rating MPCB with S/D starter for upto 10 HP motor (VFD)
1226CONTROL PANEL FOR DEDICATED OUTDOOR AIR UNIT (IP 65) Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, dead front, sheet steel, and wall/floor mounted control panels including anchoring into the wall, wiring and earthing terminating into MPCB in each panel shall be complete as per specifications as required.All internal wiring and copper earthing within the panel shall be included. Power & Control & panel cable with earthing in GI Cable tray from panel to motor shall be included in the cost.All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate remote operation through BAS. All starters shall be provided with potential free Contact.The panel shall include the following components and accessories.a. MCCB as per the ratings given below, suitable for motor duty and able to withstand fault level of 20 KA.b. DOL/SD starter as HP rating c. Terminal block for power distribution as required.d. Contactor, over load relay with built in single phasing protection.e. Phase indicating lights and indicating light for ON status.f. Digital voltmeter and digital ammeter. g. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation.h. 3 No. of Single Pole MCB"s Shall be provided at the incoming section of the starter panel for DDC Panel , fire damper actuator & as a spare.i. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. j. The item includes providing emergeny stop button along with NO/NC contacts / control wiring or any other accessorries required to complete installation in all respects. The button shall be placed near the AHU only. k. 220 / 24 V Transformer DOAS Unit-1-2 Incoming100 amp 4 pole MCCB with following accessories:96 mm x 96 mm 0-500 volt digital voltmeter with selector switches-1 set0-100 amps digital electronic ammeter with selector switch and 100/5 amps 5VA, CL.1CTs – 1 setPhase indicating light through 2 amps SP MCB -3 sets Bus Bars 250 amps TPN aluminium bus bars with heat shrinkable insulation sleeve. Outgoing (DOAS) Suitable rating MPCB for 1 Nos.7.5 HP S/D starter motor and outgoing feeder to Supply fan. Compartment shall contain direct operated digital electronic ammeters of 0-100 amps rang, Auto / Manual selector switch and ON / OFF trip indicating lamp with MCB ‘s and push button for ON / OFF status of motor - 1 set Suitable rating MCCB for 1 Nos. 5 HP S/D starter motor and outgoing feeder to exhaust/return fan. Compartment shall contain direct operated digital electronic ammeters of 0-100 amps rang, Auto / Manual selector switch and ON / OFF trip indicating lamp with MCB ‘s and push button for ON / OFF status of motor - 1 set Suitable rating MCCB with 1.5 HP DOL starter and outgoing feeder to Heat Recovery wheel Motor Compartment shall contain direct operated digital electronic ammeters of 0-12 amps rang, Auto / Manual selector switch and ON / OFF trip indicating lamp with MCB ‘s and push button for ON / OFF status of motor - 1 set.Control Panel as described above
1227PLC based Control Panel For Basement Design, manufacture, supply, installation, testing and commissioning of combined single Fan Starter cum PLC with self diagnostic feature of overload, cable heating, over temperature, inbuilt smoke detection and alarm. Control system should based on programmable logic controller (PLC) with RS485 serial interface over ModBus RTU open protocol digital communication, with Master-Slave architecture connected in Bus topology. Sensors can be connected in Bus with addressable configuration with bi-directional communication as well as analog signal configuration. PLC should be capable of configuring multiple threshold for each sensor to identify and trigger normal ventilation, fire mode etc. It should work in closed loop, feedback mode with sensors, with auxilliary power supply to the sensor transmitters. It should be easily integrated with BMS (from Master PLC Module) providing all parameter values including fan status, sensor values, threshold status, fire command etc. It should accept and offer command to & from fire alarm system.Master Panel should have colored touch-screen based HMI LCD display for – sensor values, fan status, alarm status, error & fault log, alarm location etc. System should be configurable via touch-screen with easy English driven menu. It should have password protection against unauthorized access. Programmable to run and control fan (Jet Fans, Axial Fans) operation in normal, early fire, ventilation and fire mode based on sensor values or fire alarm signal or BMS signal or Manual operation. Configurable to control fan operation of any zone based on trigger of sensor of any same or other zone. Panel should be equipped to control dual speed jet fans of given power rating based on multiple configured set points on CO concentration. It should have closed feedback signals for fan status, fan error etc. It should have overvoltage, over current, phase protection features. Manual / Auto fan mode should be accessed by LCD Display. Panel should be equipped with emergency stop mushroom type push button for emergency stop condition.Panel should be have capacity to handle:No. of Axial Fans: 4No. of CO sensors: 8 Fire Survival Power & Control wiring & panel cable with earthing in GI Cable tray from panel to motor shall be included in the cost.
1228HVAC High Side EQUIPMENT Supply, Installation, testing and commissioning of AHRI Certified water chilling unit with VFD each complete with 350 TR actual capacity sIngle semi hermetic Twin screw compressor with squirrel cage induction motor with class "F" insulation (efficiency class IE3), unit /floor mounted VFD, factory insulated chiller, differential pressure switch at chiller and condenser, Neoprene Pads, integral refrigerant piping and wiring, BMS interface Unit(Bacnet output) with all required hardwares and softwares, grooved couplings /Flanges with counter flanges for condenser and cooler water in / out connections, complete charge of refrigerant and oil accessories as required and called for accessories as required and called for automatic and safety controls mounted in advanced microprocessor based control panel with graphics and all mounted on steel frame complete as per specifications. Motor shall be suitable for 415 +- 10% 50 cycles 3 phase AC supply and motor cable terminal box shall be suitable to connect electrical cabling. Also, Winding Temperature Sensors shall be provided in the Chiller motor to prevent any Motor Burning. Refrigerant used shall be Ozone friendly R-134a as detailed in specifications. chiller to be with acoustic jacket in case Sound level exceeds 80 dBA at 1 metre distance. Chiller construction shall be in accordance with ASME / NB / PED / OEM standard.The unit shall be complete in all respect and Shall be factory tested with reports submitted and it should meet the specification, Drawing and schedule. Vendor to provide AHRI Certifed Selection Sheets to verify the efficiency levels (NPLV / IPLV) Floor/Unit mounted VFD to be providedHinged water marine boxes shall be provided at CondensersCable terminal box shall be suitable for receiving incoming Aluminium CablingBMS card shall be included in the price and vendor shall provide open protocol and suitable to connect with Modbus/ Lonwork/ BacnetMotor suitable for 415±10%, 50 cycles, 3 phase AC supply and unit mounted VFD shall be provided.The Evaporator performance shall be as follows:Energy meter to be provided by the OEM Inlet Chilled Water Temperature 54 °F ( 12.2 Deg C)Outlet Chilled Water Temperature 44 °F ( 6.7 Deg C)Fouling Factor 0.0005 FPSChilled Water Flow 840 USGPMPressure Drop Max 5 mtr The Condenser performance shall be as follows: Inlet Chilled Water Temperature 88 °F ( 31.1 Deg C)Outlet Chilled Water Temperature 98 °F ( 36.6 Deg C)Fouling Factor 0.001 FPSChilled Water Flow 1050 USGPMPressure Drop Max 9 mtr Cooling Capacity at design conditon : 350 TRMinimum COP at AHRI conditions shall be 5.4 , IPLV = 0.38 kW/TRMaximum Power consumptionat above mentioned conditions: Less than 0.63 kW/TRMaximum NPLV at design condition: 0.38 kW/TR Testing of 1 randomly selected Chiller, as per AHRI 550 - 590 in AHRI Certified Factory before dispatch of Chillers at 4 Points - 100% , 75% , 50% , 25% @ AHRI Conditions to validate COP and IPLV.
1229Supplying, installing, testing and commissioning of End Suction Back Pull Out duly factory mounted on a base with electric motor. The pump motor shall be IE 3 efficiency (minimum 90%) and suitable for 415 + 10% volts, 50 cycles, 3 phase power supply. Pumps will adhere to following performance characteristics : The pump performance shall meet the criterion laid down under ASHRAE 90.1-2016 and with minimum efficiency as specified. Thermal insulation & cladding of the chilled water pumps will be included. Secondary chilled water pumps shall operate through variable frequency drives.VFD ons Secondry pumps Shall be pump Mounted. The rating of pumps shall be as follows: Primary Water Pumps (Suitable for 350 TR Chiller ) No of Pumps 4 No. (3W+1S)Water flow rate 1050 USGPMHead 45 Ft. of waterMotor HP not to exceed 15 HPEfficiency 80% or more Primary Water pump as described above .
1230Condenser Water Pumps (Suitable for 350 TR Chiller )No of Pumps 4 No. (3W+1S)Water flow rate 1050 USGPMHead 90 Ft. of waterMotor HP not to exceed 30 HPEfficiency 80% or more Condenser Water pump as described above .
1231Supplying, installing, testing and commissioning of Variable Speed Pumping System consisting of following: Secondary Chilled Water Pumps (350 TR) Primary Variable unit No of Pumps 4 No. (3W+1S)Water flow rate 840 USGPMHead 90 Ft. of waterMotor HP not to exceed 25 HPEfficiency 80% or more Primary Chilled Water pump as described above .
1232Unit mounted Variable Frequency Drive suitable for Seondary Chilled Water Pumps Pump controller (micrprocessor based) with licensed software capable of operating the system with Modbus/Lon Works/Bacnet protocol. Quoted price shall include control/power wiring for daisy chain linking of pumps and providing signals at one point within the room. Pump controller shall be capable of controlling numbers of SCHW pumps mentioned below. Differential pressure sensor / transmitters/ sensorless control along with control cabling running in 25 mm dia MS conduit from transmitter to VFD Panel. Min. 4 pressure sensing elements shall be installed at farthest end of zone circuit. Digital display shall be provided with VFD panel which will display all critical parameters. All wiring to complete the installation shall be included as part of this item. Primary variable speed pumping system as described above. (25HP# 4 No.)
1233Supplying, installing, testing and commissioning of FRP Induced draft Cooling Towers with VFD (CTI certified) with built in PID controller, control panel (keypad and display) for air conditioning system. Each tower shall be complete with FRP basin, casing, distribution system, filling, louvers ,HDG supporters, MS painted ladders, steel/masonary supporting structure, anti vibration mounting etc. (VFD is considered as a seperate item in the BOQ) Motors shall be for outdoor application (IP55), suitable for 415±10% volt, 50 cycle’s 3 phase power supply meeting criterion as per ASHRAE standard 90.1-2016 and high efficiency (IE3 rated). Isolators at cooling tower enclosed in weather proof panel shall also be included. Selected cooling tower shall be CTI certified and meeting performance/efficiency criterion as per ASHRAE Standard 90.1-2016. The test certificates shall be provided at the time of supply. The Cooling Tower performance shall be as follows: Cooling tower suitable for 350 TR Water cooled chillerInlet Condenser Water Temperature 98 °FOutlet Chilled Water Temperature 88 °FWet Bulb Temperture 82 °FChilled Water Flow 1050 USGPMMotor HP 2 No. 7.5 HPCell Number Min. 2 Cooling Tower as described above. (2W+1S)
1234Supply, installation, testing and commissioning of Closed type pressurized chilled water expansion tank complete with necessary connection for piping, vent, valves and accessories. The requirement shall be as follows: Accessories like centrifugal Pressurization unit, pumps in N+1 etc.shall be included in quoted price for satisfactory operation. The tank shall be nitrogen precharged steel expansion tank with replaceable heavy duty butyl rubber bladder. The tank shall have suitable sized inlet connection, drain alongwith valves for isolation/shutdown of system connection and drain and charging valve connection to facilitate the on site charging of the tank to meet system requirement.  Chilled water Expansion Tank as described aboveNote- Capacity of Expansion tank shall be verified by contractor based on the total volume of the chilled water system
1235Supply, installation, testing and commissioning of Centrifugal type Air & Dirt Seperator complete with necessary connection for piping, vent, valves and accessories. The requirement shall be as follows: 300 mm dia Air&Dirt Seperator ( Chilled Water)
1236Supply, Installation, Testing & Commissioning of Pot Strainer as per the Specifications on the return water line located at the pump suction or a suitable location as suggested and suitable for CHW/CDW water flow respectively. The Pot Strainer should be capable of removing all particles. The Pot Striner shall be provided with SS304 grating.Necessary civil work required for the above equipment shall be included in this item quoted price. The Strainer shall be PN-16 rating. 300 mm for Chiller side (Insulated)
1237350 mm for Condenser side
1238a) The VFD shall have a dual 5% impedance DC link reactor (Harmonic filters) on the positive and negative rails of the DC bus to minimize power line harmonics and protect the VFD from power line transients. The chokes shall be non-saturating.b) All the VFD’s should have factory fitted IP20 enclosure protection c) EMC filters, C1 Category, Drive should support at least 3 PID loops are requiredd) Panel space and wiring shall be included under Electrical Panel sectione) Pressure sensor and wiring shall be included in the cost.Application Motor HPCooling Tower 7.5
1239ELECTRICAL INSTALLATION CHILLER PLANT PANEL ( MCC Ratings as per the final pump selection) Design, manufacture, supply, installation, testing and commissioning of the following cubicle type 2 mm thick sheet steel enclosed separate compartment for each feeder, front operated, rear connections indoor type LT motor control panel, dust and vermin proof, drawout/hinged and lockable doors, complete with internal wiring, colour coding with ferrules, bonding to earth and painting. Each MCC shall include cost of wiring, control wiring & inter locking between chillers, primary CHW pumps, condenser water pumps, motorized valves at chillers and condensers & flow switch installed in de-coupler by-pass line, in order to execute the required sequence of operation. A separate set of CTs to be provided for BAS and wiring from CT’s and voltage transducers to be brought on to separate set of terminals. All outgoing shall be provided with Stop/Manual/ Auto selector switch to facilitate operation through BAS. All starters shall be provided with potential free Contact for Connections to Building Automation System. Motor Control Centre- Section 01 (415 V) bus section consisting of : 2 No. Incoming each consisting of the following : 630A 4 Pole MCCB, 50kA with in -built Microprocessor Based O/L, S/C & E/F Release with Under Voltage Release , Shunt Release (Cable Connection) 0 - 500 volts 96 x 96 sq mm digital voltmeter with selector switch. -1Set 0 - 800 amps 96 x 96 sq mm digital ammeter with 3 No. 800/ 5 amps CT’s and selector switch.-1Set Phase indicating lamps. TPN bus bars shall be of Aluminium and shall be sleeved. Phase bus bars shall be rated at 800 amps and neutral bus bar shall be of 50% capacity. Bus Coupler # 1 Set consist of the following : 630A FP Motorized MCCB with in -built Microprocessor Based O/L, S/C & E/F Release with Under Voltage Release , Shunt Release (Cable Connection) Auxillary contacts with on/off/trip indicating lights # 1 Set Control MCB # 1No. Section-1- Outgoing-1 2 No. Suitable rating MCCB with Variable Frequency Drive (VFD) panel for 350 TR Scew chiller. Each of these compartment shall contain CT operated digital ammeter of 0-250 amps range with selector switch and indicating lamp with MCB for ‘ON / OFF’ status of chiller. 3 No. Suitable rating MCCB Star Delta starter for 15 HP motor over load relay with built in single phasing protection and outgoing feeder to Primary Chilled water pump motor. The compartment shall contain an indicating lamp with MCB for ‘ON’ status of fan motor. 3 No. Suitable rating MCCB with outgoing feeders to Adjustable Frequency Drive (AFD) panel of 25 HP outgoing feeders to Variable Flow Secondary Chilled Water pump motor. Each of these compartment shall contain CT operated digital ammeter of 0-100 amps range with selector switch and indicating lamp with MCB for ‘ON / OFF’ status of pump motors. 3 No. Suitable rating MCCB with outgoing feeders 30 HP VFD operated Condenser Water pump motor. Each of these compartment shall contain CT operated digital ammeter of 0-100 amps range with selector switch and indicating lamp with MCB for ‘ON / OFF’ status of pump motors. 4 No. Suitable rating MCCB Star Delta starter for 7.5 HP motor over load relay with built in single phasing protection and outgoing feeder to Cooling Tower Fan motor. The compartment shall contain an indicating lamp with MCB for ‘ON’ status of fan motor. Section-1- Outgoing-2 1 No. Suitable rating MCCB with Variable Frequency Drive (VFD) panel for 350 TR Scew chiller. Each of these compartment shall contain CT operated digital ammeter of 0-250 amps range with selector switch and indicating lamp with MCB for ‘ON / OFF’ status of chiller. 1 No. Suitable rating MCCB Star Delta starter for 15 HP motor over load relay with built in single phasing protection and outgoing feeder to Primary Chilled water pump motor. The compartment shall contain an indicating lamp with MCB for ‘ON’ status of fan motor.1 No. Suitable rating MCCB with outgoing feeders to Adjustable Frequency Drive (AFD) panel of 25 HP outgoing feeders to Variable Flow Secondary Chilled Water pump motor. Each of these compartment shall contain CT operated digital ammeter of 0-100 amps range with selector switch and indicating lamp with MCB for ‘ON / OFF’ status of pump motors. 1 No. Suitable rating MCCB with outgoing feeders 30 HP VFD operated Condenser Water pump motor. Each of these compartment shall contain CT operated digital ammeter of 0-100 amps range with selector switch and indicating lamp with MCB for ‘ON / OFF’ status of pump motors. 2 No. Suitable rating MCCB with outgoing feeders to Adjustable Frequency Drive (AFD) panel of 7.5 HP outgoing feeders to Cooling Tower Fan (suitable for 350 TR chilling machine) motor. Each of these compartment shall contain CT operated digital ammeter of 0-63 amps range with selector switch and indicating lamp with MCB for ‘ON / OFF’ status of pump motors.Necessary cable alleys, space for spare switches, internal wiring, control wiring / cabling and copper earthing of all equipment shall be included. All switches and other components shall be motor duty rating. Spare feeder space for following: (Only space provision) 2 No. 30 HP Spare Feeder Space and 1 No. Spare feeder for 350 TR W/C Chiller Internal switchgear for spare feedres will be installed as per future requirement. Blank space shall be provided.
1240Elevator Works SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/1088Kg· Floors :-B+G+M+11 floor (14 Stops/14 Landings)· Travel :- 56.2 mtrs.· Location of Lift Machine:- MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 900 mm wide x 2100 mm high· Clear Car size of 1600 mm wide x 2100 mm deep x 2200mm high· Lift shaft available having clear size of 9000 mm wide x 2900 mm deep, 1400mm Pit depth, 4200mm Overhead. ( 2200+2000)-------- Such 2 lifts shafts are there· Doors type :- COPO Doors with Full Glass with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.· ARD complete with necessary SMF VRLA batteries.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.· Other mechanical parts such as "T" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.· Minor civil work such as alteration work if any necessary for erection of landing door frames and it"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector (Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
1241Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1242Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
1243Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
1244Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
1245Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
1246Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
1247Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
1248Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
1249Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected.
1250Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
1251Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
1252Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
1253Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.