}

Tender For Construction Of Library Room In Village Bhatta And Parsol Yea.Wc-06, Gautam Buddha Nagar-Uttar Pradesh

Yamuna Expressway Industrial Development Authority has published Tender For Construction Of Library Room In Village Bhatta And Parsol Yea.Wc-06. Submission Date for this Tender is 21-03-2024. Building Work Tenders in Gautam Buddha Nagar Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42843920
Tender For Construction Of Library Room In Village Bhatta And Parsol Yea.Wc-06
Open Tender
Indian
Uttar Pradesh
Gautam Buddha Nagar
21-03-2024

Tender Details

Construction Of Library Room In Village Bhatta And Parsol Yea.Wc-06

Key Value

Document Fees
INR 590 /-
EMD
INR 88000.0 /-
Tender Value
INR 42.79 Lakhs /-

BOQ Items

Name of Work: Construction of Library Room inVillage- Bhatta & Parsol, yea
Sl. No. Item Description
1Earth work in excavation in ordinary soil in all of foundation trenches including dressing of the side and ramming of bottom.Lifts up to 1.50 m including getting out theexcavated soil and disposal of surplus excavated soil as directed with in a lead of 50m. (MOST/A.R./YEIDA)
2Cement concrete with 4cmgauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all material, Labour, Tools&plants etc required for proper completion of the work.
3B/W with bricks of class 150 in foundation & plinth in CM 1:4 (Based on UP PWD SOR 2020) Cement mortar 1:4 ( 1cement :4Coarse sand)
4B/W with bricks of class 150 in Super structure in CM 1:4 (Based on UP PWD SOR 2020) Cement mortar 1:4 ( 1cement :4Coarse sand)
5M-150 brick work in 1:4 one cement and four course sand 2.20 F.M. mortar superstructure but for walls of half brick thick including supply of all material, labour, T&P etc. required for proper completion of the work. (UPPWD/SOR-2020/305(a)+310A
6Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
7Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level
8Centringand shutteringincluding strutting, propping etc. andremoval of form for : foundation footings, base of column
9Centringand shutteringincluding strutting, propping etc. andremoval of form for : lintels, beams, plinth beam, grinder
10Centringand shutteringincluding strutting, propping etc. andremoval of form for : column, pillers, piers
11Centringand shutteringincluding strutting, propping etc. andremoval of form for : suspended floors, roofs, landings
12Earth work in rough excavation, banking, earth in layers not exceeding 20cm in depth clods watering rolling each layers with 1/2 tonnes roller or wooden or steel rammer and rolling every 3rd and top most layers with power roller of minimum 8 tonnes and dressing up in embankment for roads flood bank marginal bank and guide bank or filling up ground depression as per MORTH. All kinds of soils (only for where mechanical can"t be reach/ move) (based on SOR)
13Thermo-Mechanically Treated bars of grade Fe-500D or more./Cold twisted bars. (DAR/5.22.6/Based on UPPWD/SOR-2020))
1412mm cement plaster of mix: 1:4 (1 cement : 4 coarse sand)BASED on UP PWD SOR 2020
156mm cement plaster of mix: 1:3 (1 cement : 4 coarse sand)BASED on UP PWD SOR 2020
1615mm cement plaster of mix: 1:6 (1 cement : 4 coarse sand)BASED on UP PWD SOR 2020
17Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
18Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade
19Painting with synthetic enemel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
20Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 90mm dia
21Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mmnominal size aggregate
22Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
23Providing and fixing water closet squatting pan (Indian type W.C. pan with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
24Providing and fixing wash basin with C.l. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
25Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia .Pipes.
26Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs C) After two days of proper curing applying a second coat of cement slurry using 2.75kg! sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre doth of approved quality in top layer of plaster and finally finishing the surface with trowe’ with neat cement suvr an making pattern ot 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge:
27Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suttable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
28Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth
29Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600mm (DAR/11.41.2/Based on UPPWD/SOR-2020))
30Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DAR/8.31/Based on UPPWD/SOR-2020))
31Providing and fixing brass bib cock of approved quality: 15 mm nominal bore (DAR/18.15.1/Based on UPPWD/SOR-2020))
32Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore (DAR/18.17.1/Based on UPPWD/SOR-2020)
33Providing and fixing nahani trap 75x100mmincluding all complete.
3420 mm cement plaster of mix 1:4 (1cement : 4 coarse sand)
35Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame and diagonal braces of 40x40x6mm angle iron, 3mm M.S. gusset plates at the junction and corners 25mm dia pulley, 40x40x6mm angle and T-iron guide at the top and bottom respectively including applying a priming coat of approved steel primer.
36Renewing panes of glass in door, window & ventilators or fixing in the new work with 3mm thick glass panes fixed with brads & putty includung supply of all material , labour , tools & plants required for proper completion of work
37Prroviding and fixing ISI Mark 3 layer prelaminated particle board conforming to grade 2 type-III of IS-12823/20B laminated with 0.6-0.8 mm thick laminate conforming to IS-2046/1995 and balancing lamination of 0.5 mm thick on the back side (size 700*750*430) including all complete
38supply of work SB collection office/visitor chain with sheat DXWXH 400*400*450 mm padded with polyurithane foam complete
39supply wook at site SB collection executive table of 3 layer Prelaminated particle board (wood product) of grade 2 type 2 of IS-12823/latest 1830 mm 950 mm 750mm including all complete
40Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
41providing and fixing glass strip in joint of terazo/ cement concrete floors 40mm wide and 4mm thick (DAR/11.13.1 Based on UPPWD SOR 2020)
42Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
43Wiring point for light in 1.5 sq. mm. PVCinsulated singlecorecopperconductor cable (inPVCconduit with 1.5sq.mm. FRLSH PVC insulated multistrand copperconductor cable as earth wire drawn inside conduit.)and5 Amp.flush typeswitch& ceiling rose/angle/batten holderfixedwith3mmthickphenolic laminate backalitesheet withbrass machinescrews andcup washers mounted overexisting M.S.switch boardbox/junction boxwith supplyofallmaterial, labour& T&P etc. requiredforproper completion of the work complete in all respect, as directed by Engineer in charge PWD-2018 PS No-174C
44Supply and Wiring of submains with 2 nos. of 2.5 sq. mm. FRLSH PVC insulated1100 Vgrade multistrand singlecore copper conductorcable in 25mm dia heavy duty (2mm thick) PVC conduitwith2 nos 2.5 sq.mm.FRLSH PVC insulated multistrand copperconductor cable asearth continuity wire drawn in conduit complete in all respect, as directed by Engineer in charge PWD-2018 PS No-261C
45Supply and fixing of power plug with 20 Amp./250 voltflush type modularswitchand 5 pin 20 A/250 voltflush typeuniversal modular socket switch on concealed M.Sboxincluding supply of allmaterial, labourT&Petc. complete in all respect, as directed by Engineer in charge .PWD-2018 PS No-1139A
46S&F surface/flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. PWD-2018 PS -1024A
47S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve complete in all respect, as directed by Engineer in charge.PWD-2018PS -1002CAT-A
48S&F of 40Amp. DP MCB (10 KA) C Curve complete in all respect, as directed by Engineer in charge. PWD-2018 PS No-1010 Cat-A
49Installing, testing and comissioning of ceiling fan including wiring the door roads of standard length (upto 30m) width 1.5 FRCS PVC insulated, copper conductor, single core cable, including providing & fixing phenolic laminated sheet cover on the fan box etc is required
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail