Tender For Provision Of Fire Sensors, Alarms And Modular Fire Extinguishers At Ins Karna, Visakhapatnam, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Provision Of Fire Sensors, Alarms And Modular Fire Extinguishers At Ins Karna, Visakhapatnam. Submission Date for this Tender is 08-04-2024. Fire Extinguishers Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42834484
Corrigendum : Tender For Provision Of Fire Sensors, Alarms And Modular Fire Extinguishers At Ins Karna, Visakhapatnam
Open Tender
Indian
Andhra Pradesh
visakhapatnam
08-04-2024

Tender Details

Provision Of Fire Sensors, Alarms And Modular Fire Extinguishers At Ins Karna, Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
INR 24 Lakhs /-

BOQ Items

Name of the Work: Provision of Fire Sensors, Alarms and Modular Fire Extinguishers at INS Karna, Visakhapatnam
Sl. No. Item Description
1Supplying, Fixing, Testing & Commissioning of Modular Clean Agent type Fire Extinguisher of 10 KG Capacity fixed / hanged on Wall/Ceiling with suitable Clamps and Necessary Supports complete all as specified and as directed.
2Supplying, Fixing, Testing & Commissioning of Modular Clean Agent type Fire Extinguisher of 5 KG Capacity fixed / hanged on Wall/Ceiling with suitable Clamps and Necessary Supports complete all as specified and as directed.
3Supplying, Fixing, Testing & Commissioning of ABC type Fire Extinguisher of 10 KG Capacity fixed / hanged on Wall/Ceiling with suitable Clamps and Necessary Supports complete all as specified and as directed.
4Supplying, Fixing, Testing & Commissioning of Microprocessor Based Conventional Fire Alarm, with 2 Zones for Manual Call Point, Detectors and normally Open Dry Contact Devices and complying with UL-864 and NFPA-72 and consisting of 16 X 2 Dot Matrix LCD Display and RS485 Communication Port to establish connection with the Long Range Network and shall be capable of making necessary Output Arrangement for Integration of Master Panel at Long Range Communication by intranet or any other network mode including Standby [Battery] Backup of 24 Volts DC Power Supply with Built-in Charger complete all as specified and as directed.
5Supplying, Fixing, Testing & Commissioning of Microprocessor Based Conventional Fire Alarm, with 4 Zones for Manual Call Point, Detectors and normally Open Dry Contact Devices and complying with UL-864 and NFPA-72 and consisting of 16 X 2 Dot Matrix LCD Display and RS485 Communication Port to establish connection with the Long Range Network and shall be capable of making necessary Output Arrangement for Integration of Master Panel at Long Range Communication by intranet or any other network mode including Standby [Battery] Backup of 24 Volts DC Power Supply with Built-in Charger complete all as specified and as directed.
6Supplying, Fixing, Testing & Commissioning of UL Listed Conventional Smoke Detector with Dual LED Indication for 360 Degree Visibility and shall be Polarity Insensitive, Insect Filter Chamber, easy to install, Advanced Detection and Communication Protocol, suitable for Operating Voltage Range of 9 – 33 Volts DC complete all as specified and as directed.
7Supplying, Fixing, Testing & Commissioning of Sounder equipped with indication in case of Fire and Emergency and the Horn output Db level shall be between 80 to 100 Db when measured at a distance of one meter and complying to NFPA 72 Standards, suitable for Operating Voltage Range of 18 – 30 Volts DC [24 V Nominal DC] with current less than 100 mA built with FR ABS Plastic, IP 40 Rated complete all as specified and as directed.
8Supplying, Fixing, Testing & Commissioning of Analogue Addressable type Fire Alarm Control Panel along with Network Interface Card and Lead Acid Battery Backup for 08 Hours Normal Operation and 15 Minutes Alarm Operation, the Control Panel, Battery Charger etc. shall be LPCB approved and complying with BS EN 54-2 and EN 54-4, Four Loop Panel each Loop consists Minimum with 198 Devices maximum up to 254 Devices and Modules per Each Loop and suitable for Operating Voltage of 230 Volts, 50-60Hz, AC, Max PSU rating 4A/24 DC Sounder Kit 1 or 2 Amps, Auxiliary Output 24 Volts DC 1250 mA, Ingress Protection IP 30 and Panel consists Networking up to 16 Loops and suitable for configuration by Keypad and PC, RS 485 Port for Peripheral Connections, 2 Programmable Output Sounder Circuit Fire and Fault Auxiliary Relays and supported Graphics Software complete all as specified and as directed.
9Supplying, Fixing, Testing & Commissioning of Addressable Monitor Module UL listed for Third Party Device Integration to enable Addressing or Remote Devices or any other Fire Alarm Control Panels complete all as specified and as directed.
10Supplying, Fixing, Testing & Commissioning of 12 Volts, 7AH Lead Acid Batteries for Secondary Power Supply Backup for Fire Alarm Control Panel complete all as specified and as directed.
11Supplying, Fixing, Testing & Commissioning of Loop Card Supporting Addressable Panel suitable for Analogue Addressable type Fire Alarm Control Panel as specified Serial Item No. 8 above and suitable to enable 254 Devices per Card complete all as specified and as directed.
12Supplying, Fixing, Testing & Commissioning of Addressable Manual Call Point is made up of a High Quality PVC Housing with Breakable Glass and Resettable Switch inbuilt and suitable for operating with 24 Volts, DC Power Supply and 30 mA Operating Current suitable for Conventional Fire Alarm Control Panel complete all as specified and as directed.
13Supplying, Fixing / Laying, Testing & Commissioning of PVC Insulated, Sheathed Multistranded Flexible Copper Conductor Cable of size 2 Core, 2.5 Sq.mm, FRLS, 1100 Volts Grade including Saddling and Glanding, Termination and also including necessary Earthwork Excavation in any type of Soil, Return Filling and Removal of Surplus Soil for laying of cable complete all as specified and as directed. Note: Rate quoted is deemed to be including the cost of suitable size Double Compression Copper Stainless Steel Cable Gland, Crimping Type Cable Lugs, Sockets etc., Earthwork Excavation in any type of Soil / Hardstanding, Return Filling and Removal of Surplus Soil. Nothing shall be paid extra on this account.
14Supplying, Fixing / Laying, Testing & Commissioning of Heavy duty PVC Conduit, 25 mm dia laid on floors or laid in trenches etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Flexible Copper Cable complete all as specified and as directed.
15Supplying and laying GI Tubing of 50 mm Bore, Medium Grade conforming to IS – 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc. as in Cable Protection and laid on floors or laid in trenches including testing complete all as specified and as directed.
Disclaimer :