Tender For Renovation Works For Cisf Barrack Buildings, Construction Of New Quarter Guard Building And Allied Works, talcher-Odisha

Projects And Development India Limited-PDIL has published Tender For Renovation Works For Cisf Barrack Buildings, Construction Of New Quarter Guard Building And Allied Works. Submission Date for this Tender is 15-04-2024. Building Work Tenders in talcher Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

42831547
Corrigendum : Tender For Renovation Works For Cisf Barrack Buildings, Construction Of New Quarter Guard Building And Allied Works
Open Tender
Indian
Odisha
talcher
15-04-2024

Tender Details

Renovation Works For Cisf Barrack Buildings, Construction Of New Quarter Guard Building And Allied Works On Percentage Rate Basis

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Mar-2024 Amendment-I Date 15-04-2024

Key Value

Document Fees
Refer document
EMD
INR 1500000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: TENDER FOR RENOVATION WORKS FOR CISF BARRACK BUILDINGS, CONSTRUCTION OF NEW QUARTER GUARD BUILDING AND ALLIED WORKS” ON PERCENTAGE RATE BASIS AT TALCHER FERTILIZERS LIMITED, TALCHER, ODISHA
Sl. No. Item Description
1CIVIL & STRUCTURAL WORKS (PART- I)
2Archictect Planner
3Engagement of the services of Archictect Planner forplanning of the renovation works of thebuildings as per scope of works.
4Dismantaling & Demolishing
5Demolishing plain cement concrete under floor including disposal of material outside Building premises as directed by Engineer-in-charge.
61:3:6 or richer mix.
7Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish as directed by Engineer-in-charge.
8Dismantling of existing tiles in floor and wall laid in cement mortar as directed.
9Dismantling of existing G.I. water supply pipes with all fittings / fixtures / clamps as per instruction of Engineer- in charge.
10Dismantling of C.I. pipes (waste water & soil water) with fittings/fixtures and clamps including traps as per instruction of Engineer- in charge.
11Dismantling C.I. or asbestos rain water pipe with fittings and clamps including disposal within 200 metres lead:
12Taking out cinders and other filling materials, drying it and backfilling it in position in sunken floor of toilet.
13Dismantling doors, windows and clerretory windows & ventilator (steel or wood) shutter including chowkhats, architravs, holdfasts etc. complete
14a) Of area 3 Sq.m. and below
15b) Of area beyond 3 Sq.m.
16Demolishing brick work manually/ by mechanical means including disposal of unserviceable materialwithin 200 metres lead as per direction of Engineer-in-charge.
17In cement mortar
18Dismantling manually/ by mechanical means including disposal of unserviceable materialwithin 200 metres lead as per direction of Engineer-in-charge :
19Bituminous road
20Demolishing water proofing in terracing Upto sound concrete and disposal of materialwithin 200 metres leadas per direction of Engineer-in-charge.
21Dismantling steel work manually/ by mechanical means in built up sections without dismembering within 200 metres leadas per direction of Engineer-in-charge.
22Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material with in 200 meters lead as directed by Engineer-in-charge.
23Demolishing R.C.C. work manually/ by mechanical means including disposal of unserviceable materialwithin 200 metres lead as per direction of Engineer - in- charge.
24Dismantling precast concrete or stone slabs in walls, partition walls etc.within 200 metres lead :Thickness up to 40 mm
25Earth work
26Excavating trenches of required width for pipes, cables, etc including excavation for sockets and dressing of sides, ramming of bottoms depth up to 1.5 m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layerby ramming, watering, or dewatering etc. and disposing of surplus excavated soil as directed, within TFL Premises:
27Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
28Earthworkinexcavationin foundations of buildings, footings,columns,plinthbeams,walls,machine/ equipment foundations,isolatedpits, pavements, trenchesforpipelines /cables, pipe sleepers, drains, etc., to the required levelsand gradesinboth dry and wet conditions,includingdressingof sides and ramming of bottoms, getting out excavated earthwith liftupto1.5M and disposal ofsurplusexcavatedmaterials within a lead of 50 M including stacking, levelling anddressing etc., complete as per direction of Engineer-in-Charge(E.I.C.)in allkindsof soils as defined in IS: 1200includingproviding temporarysupportsto all service lines suchasoverheadand undergroundwater,sewageand drainpipes,cablesetc.and shoring and strutting wherever necessary, complete in all respects as per direction of Engineer-in-Charge. .
29a) All kinds of soil
30b) Same as above item but Lift from 1.5 M to 3.0 M.
31c) Same as above item but Lift from 3.0 M to 4.5 M.
32Backfilling with available excavated goodearth(excluding rocks / boulders), as approved and directed byEngineer-in-Charge, intrenches, plinth, under floors, sides of foundation etc.,at all depths in layers not exceeding 20 cms. in thickness including consolidatingand dressing each deposited layer byrammingand wateringwith lead upto 200 m, completeinallrespects.
33Supplying and filling withavailable good earthbrought from Inside TFL premises /as approved by the Engineer -in-Charge intrenches, plinth, under floors, sides of foundation etc.,at all depths in layers not exceeding 20 cms. in thickness including consolidatingand dressing each deposited layer byrammingand watering(Rateshall includeall transportation, loading and unloading, etc., and nothing extra will be paid on this account, including compaction under floor with mechanical vibrater / road roller including dewatering).
34Plain Cement Concrete & RCC
35Providing and laying plain cementconcrete,machine mixedandmechanically vibrated in foundations,plinth,under floors,etc.,includingall necessarycostofcentringand shuttering :
36a) 1:5:10 (1 cement: 5 coarse sand:10 graded stone aggregate20 mm nominal size).
37b) 1:4:8 (1 cement: 4 coarse sand:8 graded stone aggregate20 mm nominal size).
38c) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
39Providing and laying cementconcrete in retaining walls, return walls, walls (any thickness), slab including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, including the cost of centering, shuttering and finishing: - 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
40Providing and laying in position specified grade ofreinforcedcementconcrete, machine mixed, mechanically vibrated and finished to a fairface but includingthe cost of centring and shuttering excluding reinforcement insuperstructureat all heights for columns,pillars,posts, attachedpilasters, portals, struts, inclined posts,pedestals ,Beam, lintel, walls, Roof, Slabs,staircase, equipmnt pedastal etc (all type of super-structure works),completein all respects as per direction of Engineer-in-Charge.
41Design mix M25 grade concrete
42Design mix M30 grade concrete
43Providing and laying in positionreinforced cement concrete in foundations, walls, plinth beams etc. including the cost of centring, shuttering, finishing all completebut excluding reinforcement - All work up to plinth level
44a) Design mix M20 grade concrete
45b) Design mix M25 grade concrete
46c) Design mix M30 grade concrete
47Repairing & Renewing existing RCC/Cement concrete works in patches including chipping / dismantling the damaged portion to required depth/thickness and re-doing the same with rich cement concrete/cement mortar and making good the same as the existing shape. Including scaffolding, centering, shuttering and disposal of unserviceable material within 200 metres lead etc. Complete in all respects as per direction of Engineer-in- Charge.
48Supplying, cutting, cleaning, straightening, bending, hoisting and placing in position and binding with 18 SWG annealed wire, reinforcement bar of high yield strength Corrosion Resistance Steel with Fe500D properties conforming to IS:1786 with minimum yield strength of 500 N/sq,mm forall R.C.C. works including all necessary handling at all heightsand depths complete in all respects and as per direction of Engineer-in-Charge.
49Grading roof for water proofing treatment with - Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size),with using waterproof powder/chemical.
50Neat cement punning.
51Supplying,fabricating and fixinginpositionM.S. holdingdown bolts assemblyconsistingof bolts, heads,nuts, washersetc.,andthelike includingembeddingincement concrete/R.C.C. worksasper approved drawings complete inall respectsincludingone coat of approvedqualityanti-corrosive paintovera coat of approved qualityprimer.(All materials supply are in contractor’s scope.
52Brick Work
53Providing and constructing Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength inincementmortar 1 : 6 ( 1cement:6 coarse sand )inwalls, etc. at all depths, places and positions including raking out joints, curing, scaffolding etc. complete excluding plastering and painting.
54Half brick masonry withnon modular fly ash bricks of class designation 7.5 in foundations and plinth in :
55Cement mortar 1:4 (1 cement : 4 coarse sand)
56Half brick masonry with non modular fly ash bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
57Cement mortar 1:4 (1 cement : 4 coarse sand)
58Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.
59a)    With cement mortar 1:4 (1 cement : 4 fine sand)
60Finishing
6112 mm thick cement plaster 1:6 (1 cement: 6 fine sand) after properly cleaning etc. as per instruction of Engineer - In-charge.
6215 mm thick cement plaster 1:6 (1 cement: 6 fine sand) after properly cleaning etc. as per instruction of Engineer - In-charge.
636mm thick cement plaster to ceiling of mix 1:3 (1 cement: 3 fine sand).
64Wall painting with Plastic Emulsion Paint / acrylic emulsion paint with one coat of primer of approved brand and manufacture to give an even shade :
65a) One or more coat on old work.(Including scrapping and sand rubbing & preparing the smooth surface)
66b) New work (two or more coats) over and including water thinnable priming coat with cement primer
67Finishing walls with 100% Premium acrylic emulsion paint with one coat of primer having VOC less than 50 gm/litre and UV Resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives withapproved manufacture (Asian/ Nerolac/ Berger or equivalent), quality and shades over exterior walls including labour, materials, equipment, handling, transportation, finishing, scaffoldingand preparing the surface Including Filling of cracks with water proof materials etc. Cleaning stain from floors, walls, glass panes etc. all completeinstructions of the Engineer at all elevations. Roller to be used in the paint application.
68a)  On new work
69b)On old work
70Distempering with 1st quality acrylic distemper (ready mixed) with one coat of primer having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.(Two or more coats over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre.
71Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
72Melamine polishing on wood work on old and new work (one or more coat), matt/glossy as directed by EIC.
73Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :
74a) 200x10 mm
75b) 150x10 mm
76c) 100x10 mm
77Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
78Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.
79a) 40 mm
80b) 50 mm
81Providing and fixing bright finished brass handles with screws etc.complete:
82a) 125 mm
83b) 100 mm
84Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge
85Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.
8625mm Diameter
87Flooring
88Providing and laying Vitrified finish ceramic floor tiles 600mm x 600mm (thickness to be specified by manufacturer) of first quality conforming to IS: 15622 of reputed make as per approved Vendor list in all colours, shade and design as approved by E.I.C. laid on 20mm thick cement mortar (1 cement: 4 coarse sand) including pointing the joints with white cement and matching pigment of matching shade to match the level of existing floor complete in all respect at any level.
89Providing and laying Vitrified finish ceramic floor tiles on skirting made from tiles 600mm x 600mm (thickness to be specified by manufacturer) of height As per directed by EIC. of first quality tiles conforming to IS:15622 of reputed make as per approved Vendor list in all colours, shade and design as approved by E.I.C. laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including pointing the joints with white cement and matching pigment of matching shade complete in all respect at any level.
90Providing and laying 1st quality ceramic glazed tiles 300mm x 300mm conforming to IS: 15622 of minimum thickness 5mm of approved make like reputed make as per approved Vendor list on walls, skirting, risers of steps and dados,in all colours, shade and design as approved by E.I.C.over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per Sq.m. including pointing in white cement mixed with pigment of matching shade complete.
91Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing Mechanically as per directed by EIC. complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
9225 mm thick
93Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing Mechanically as per directed by EIC.complete.
94Sanitary Installations
95Providing and fixing Chlorinated Polyvinyl Chloride (UPVC/CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
96a) 15 mm nominal outer dia pipes
97b) 20 mm nominal outer dia pipes
98c) 25 mm nominal outer dia pipes
99d) 32 mm nominal outer dia pipes
100Providing and fixing soil/ waste PVC pipes as required connecting properly with old and new existing pipe and filling all joints as required at any level (including tees, bends, plain junction, stays & clamps and other fixtures as required complete in all respect
101a) 75 mm dia.
102b)100 mm dia.
103Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid with necessary opening (area less than 0.5 sqm) over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm"
104a) Granite of any colour and shade, area of slab upto 0.5 Sq.m.
105b) Granite of any colour and shade, area of slab over 0.5 Sq.m.
106Providing and fixing vitreous china wash basin of Parryware or approved make and colour with C.I. brackets 15mm C.P. brass Pillar taps Jaquar, no.011, 32mm C.P. brass waste of standard pattern , including painting of fittings and C.I. brackets, cutting and making good the walls wherever required.
107a) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
108b) White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked .
109Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) of Cera make or equivalent with seat and lid, 10 litre low level white PVC flushing cistern with manually controlled device conforming to IS: 7231 with all fittings and fixtures With jet spray all complete including cutting and making good the walls and floors wherever required, including providing and fixing jet to W.C. Pan(European).
110W.C. pan with ISI marked white solid plastic seat and lid self closing type.
111Providing and fixing C.P. brass bib cock of Jaquar / Cera / Hindware / Parryware or equivalent make, chrome finish of approved quality and 15 mm nominal bore.
112a) Long body bib cock
113b)Short body bib cock
114Providing and fixing C.P. brass angle valve, 15 mm nominal bore of Jaquar make no.053 chrome finish or equivalent for Wash basins, urinals etc. of approved quality conforming to IS:8931
115Providing and fixing toilet paper holder C.P. brass of approved make Jaquar / Cera / Hindware / Parryware or equivalent chrome finish
116Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same material with snap fitting of approved colour and make, complete in all respect.
117Providing and fixing PVC waste pipe 32mm or 40mm rigid with elbow, tee, reducer etc. as required to complete in all respect to wash basin etc.
118Providing and fixing CP Jalli of approved make for traps/gully traps etc.
119Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :
12020 mm nominal bore
121Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
122Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required :
123Single half stall urinals with 5 litre P.V.C. automatic flushing cistern
124Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
125Kitchen sink with drain board (510x1040 mm bowl depth 225 mm)
126Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
127White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
128Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
129Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
130Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
131Providing Gola 75mm x 75mm in cement concrete 1:2:4 (1cement: 2 coarse sand: 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design.
132Providing and fixing trap of any type (self cleansing design with or without vent arm complete including cost of cutting and making good the walls and floors.
133a) PVC make, 100 mm inlet & 100 mm outlet.
134Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
135110 mm diameter
136Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
137Providing and fixing Chlorinated Polyvinyl Chloride (UPVC/CPVC) pipes, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge
138a) 40 mm nominal outer dia Pipes
139b) 50 mm nominal outer dia Pipes
140Providing and fixing Ball valve with C.I. wheel of approved quality (screwed end)
141a) 25 mm nominal bore
142b) 40 mm nominal bore
143c) 50 mm nominal bore each
144Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
145a) 150 mm dia. R.C.C. pipe.
146b) 250 mm dia. R.C.C. pipe
147c) 300 mm dia. R.C.C. pipe
148Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
14925mm nominal bore, weighing not less than 62 gms.
150Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
151Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble
152a) Area of slab upto 0.50 sqm
153b) Area of slab over 0.50 sqm
154PTMT Ball Cock 25mm complete with Epoxy Coated Aluminium Rod & H.D. Ball.
155PTMT Ball Cock 40mm complete with Epoxy Coated Aluminium Rod & H.D. Ball.
156CP Brass Single lever telephonic wall mixer of approved make
157Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
158100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 .
159Doors, Windows & Ventilators
160Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
161Kiln seasoned and chemically treated hollock wood or equivalent grade wood
162Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
163Kiln seasoned and chemically treated hollock wood or equivalent grade wood (30 mm thick shutters)
164Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
165a) Kiln seasoned and chemically treated hollock wood or equivalent grade wood
166b) Ply wood 5 ply, 9 mm thick Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1)conforming to IS 1328 BWR Type
167c) Particle Board 12 mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS :3087 marked
168Providing and fixing ISI marked flush door shutters conforming to IS: 2202, core of block construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
16930 mm thick non-decorative type including ISI marked stainless steel butt hinges with necessary screws.
170Providing and fixing glazed shutter for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked butt hinges bright finished of required size with necessary screws.
17130 mm thick Kiln seasoned and chemically treated hollock wood or equivalent garde wood
172Providing and fixing 25 mm thick shutters for cup board etc. :
173Panelled or panelled & glazed shutters : Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws.
174Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters.
175With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock woodor equivalent garde wood.
176Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. direction of Engineer-in-charge.
177Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
178Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
179Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener.
180Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, of HINDALCO,JINDAL, or Equivalent fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
181For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
182Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
183With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm), along with SS jali sutter.
184With float glass panes of 5.0 mm thickness (weight not less than 10 kg/ sqm), along with SS jali sutter.
185Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge; With stainless steel cover plate minimum 1.25 mm thickness.
186Water Proofing Treatment
187Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Armourcrete of M/s The Structural water proofing Company Pvt. Ltd. or Tapecrete of M/s CICO Engineering Service consisting of applying: a)  First layer of slurry of cement @ 0.488 Kg/Sq.m mixed with Armourcrete or Tapecrete @ 0.253 Kg/Sq.m. This layer will be allowed to air cure for 4 hours. b)   Second layer of slurry of cement @ 0.242 Kg/Sq.m mixed with Armourcrete or Tapecrete @ 0.126 Kg/Sq.m. This layer will be allowed to air cure for 4 hours follwed with water curing for 48 hours. (The rate includes preparation of surface , treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry.
188Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : - 3 mm thick
189Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCCslab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
190With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
191Paver Block & Fencing
192Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
193Made of G.I. wire of dia 4 mm
194Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
195Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer"s specifications & direction of Engineerin-Charge.
19680mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.
197Handrailing & Gate
198Providingand fixingM.S pipehandrailing (medium grade) conforming to IS-1239 consisting of top and middle horizontalrailsof40mmdia.and32 mmdia. nominalbore respectively, 1050 mm high upright membersof 40 mm dia. nominalboreat1500 mm maximumdistancecentretocentreofeach memberincluding all joints, bends , elbows, andspecialsas required and upright members welded or bolted to structural steel work/toeplatesor welded toM.S. insertplates with M.S. lugs embedded in R.C.C. works, complete in all respects and as per direction of Engineer-in-Charge .
199Twocoatsof chlorinated rubber based paintatdryfilm thicknessof40 microns per coat over two coats ofhighbuilt zincphosphateprimer compatible tochlorinatedrubberbased paint at dry film thickness of 25 microns per coat.
200Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
201In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
202In stringers, tread, landing of staircase including use of chequered plate whereever required
203Structural steel work in single section or bolted, riveted,welded built up section,fixed with or without connecting plate, including cutting, hoisting, fixing in position and painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - new work with two coats inculding a coat of approved steel primer and a coat of mordant solution with 38 gms of copper acetate in a litre of soft water.
204Providing, fabricating and fixing in position double leaf gates of any height with one wicket door within the main gate, all made out of structural steel sections such as M.S.Angles,Tees,Channels,Plates,Flats,etc.,forall horizontal,verticaland diagonal members, M.S.Gusset plates including providing and fixing in position at all heights harddrawn steel wire fabric mesh of size 75 mm x 25 mm and weight not less than 7.75 kg/sq.m. welded with frames, includingprovidingand fixing necessary lock plate, handles, locking arrangement and other fittings, drilling of holes wherever required, welding etc. includingprovidingnecessaryhinge platesweldedtoinsert platesembeddedin RCC columns, bolts and nutsforhingeetc. includingprovidingandapplyingpainting,completeinall respects anddirectionofEngineer-in-Charge :
205Withprovidingand applying two coats ofhighbuildzinc phosphate primer of approved brand and manufacture compatibleto chlorinated rubber paint at a dry film thickness of 50 micron per coatonstructuralsteel work afterpreparationofsurfaces including providing and applying two coats of chlorinatedrubber basedpaint of approved colour, brand and manufacture atadry filmthicknessof 50 microns per coat
206Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
207Fixed to openings /wooden frames with rawl plugs screws etc.
208Providing and fixing rolling shutters of approved make made of 80 mm wide MS laths and interlocked together through their entire length and jointed together at the ends by end locks, mounted on specially designed pipe shaft with bracket plates, guide channels and arrangement for inside and outside locking with push-pull operation complete including cost of wire spring and hood cover for the shutters andpainting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - new work with two coats inculding a coat of approved steel primer and a coat of mordant solution with 38 gms of copper acetate in a litre of soft water.
209Extra for providing mechanical device chain and crank operation for operating rolling shutters. - Exceeding 16.80 sqm in the area
210Hotriculture & Landscape
211Supplying sludge/manure at site including royalty and carriage upto 5km complete (sludge measured in stacks will be reduced by 8% for payment).
212Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 60 days or more till the grass forms a thick lawn (korean lawn) free from weeds and fit for mowing and disposal of rubbish as directed, including supplying good earth if needed but including the cost of sludge or manure (The manure/sludge shallbe paid for separately).
213Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
214a) Trees Plant
215b) Shrubs Plant
216c) Hedge Plant
217Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level, surface dressing of the ground including removing in-equalities not exceeding 15 cm deep and removal of rubbish lead up to a distance of 50 m (lift up to 1.5 m),outside the periphery of the area cleared.
218Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
219a) Beyond 30 cm girth upto and including 60 cm girth
220b) Beyond 60 cm girth upto and including 120 cm girth
221c) Beyond 120 cm girth upto and including 240 cm girth
222d) Above 240 cm girth
223Pruning, trimming, shaping of trees /shrubs (ht 15 feet and above) i/c removal of cut materials upto 50mt. Lead, as per direction of officer in charge. T&P shall be arranged by the contractor.
224Miscellaneous
225Disposal of excavated earth / building rubbish / malba /coal ash and similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to municipal approved dumping ground or as approved by Engineer-in-charge, for lead distance upto 2 km including all lifts involved.
226Same as item no. 1 but for lead distance from 2- 5 km
227Same as item no. 1 but for lead distance from 5- 10 km
228Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
22912.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
230Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1cement : 2 coarse sand) to the full depth of the hole :
231With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
232Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
233With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
234Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:
235With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
236Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
237Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush andhoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
238a) Bars upto 12 mm diameter
239b) Bars above 12 mm diameter
240Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
241a) 75mm average thickness
242b) 50mm average thickness
243Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.
244Upto and including 12mm dia.
245Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
246a) SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
247b) Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
248Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
24912 mm average thickness.
250Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness. Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer (But shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering,strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)
251a) 50mm thick in Grade M 25 with cement content not less than 330 kg per cum
252b) 75mm thick in Grade M 25 with cement content not less than 330 kg per cum
253Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member. Note: Rates shall be for finished surface area of concrete and shall include the cost of making holes in existing RCC slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved Super-Plasticiser for rendering concrete as flowable self compacting and SBR polymer (but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering,strutting, propping etc) (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)
254a) 50mm thick in Grade M 25 with cement content not less than 330 kg per cum
255b) 75mm thick in Grade M 25 with cement content not less than 330 kg per cum
256L shaped 100mm long, 10mm dia mild steel shear key
257Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge.
258Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
2591.00 mm thick with zinc coating not less than 275 gm/m²
2600.8 mm thick with zinc coating not less than 275 gm/m²
261Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps, Suspended floors, roofs, landings, balconies and access platform.etc.
262Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer"s specification as per direction of Engineer-in-Charge all complete.
263With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles
264Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete :
26525 mm thick
266Providing & Laying of Pebbles (20mm to 50mm) round in shape of good quality, free form organic material sulphates or any deleterious material.
267Providing and fixing 16 mm M.S. Fan clamps of standard shape andsize in existing R.C.C. slab, including cutting chase, anchoring clampto reinforcement bar, including cleaning, refilling, making good thechase with matching concrete, plastering and painting the exposedportion of the clamps complete.
268Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
269Supplying chemical emulsion in sealed containers including delivery as specified. - Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
270Supplying,fabricatingandfixing in position S.S. anchorplates (SS 304), hooks, insert plates, S.S. flats,S.S. angleinsertsand thelikeincluding welding M.S. lugs, etc.,andembeddingin cementconcrete /R.C.C. works as per approved drawingscomplete in all respects and as per direction of Engineer-in-Charge.
271Supplying,fabricatingandfixingin position M.S. anchorplates, hooks, insert plates, M.S. flats,M.S. angleinsertsand thelikeincluding welding M.S. lugs, etc.,andembeddingin cementconcrete /R.C.C. works as per approved drawingscomplete in all respects and as per direction of Engineer-in-Charge
272Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
273Geo-technical Investigation
274To conduct Geo-technical Investigation for design of foundation and to submit report for information to Owner/PMC, covering all relevant data such as soil profile up to 15-20 m, minimum 3 no."s 150mm bore hole, SPT, PLT, ERT, soil properties, rock properties and interpretaion of results, net safe bearing capacities at various depth and sizes etc, including all tools & tackles, mobilization, complete in all respects.
275Rain Water Harvesting
276(EXCAVATION, PCC, RCC, SHUTTERING, REINFORCEMENT & BRICK WORK SHALL BE PAID SEPERATELY AS PER ITEM SPECIFIED ABOVE)
277Providing, hoisting and fixing precast reinforced cement concrete work including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
278Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
279Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
280Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
281Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
282Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, for all depth below ground level.
283Upto 300 mm dia bore hole for all types of soil.
284Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
285Upto 200 mm nominal size dia
286ELECTRICAL WORKS(PART- II)
287LIGHTING
288Supply, Installation, Testing and Commissioning of prewired wall/ceiling/false ceiling mounted type following LED lighting fixtures including providing & fixing LED lighting fixtures, electronic drivers,condensers,internal & external reflectors, louvers, etc. Including handling, transportation from owners store to erection site, unpacking, inspection; checking of internal wiring; Erection in position on false ceiling / floor etc ,cable glanding, crimping of lugs and connections at fixtures; supply of all erection materials Including necessary GI hardware, GI clamps, GI brackets, civil masonry materials; all work, labour and materials complete as per drawings, specifications, codes and standards and directions of Engineer in charge.High quality LED tube batten complete with2X20W tube (T5) eco friendly, having = 2000 lumen output, CCT-6500K, IP-20, luminous efficacy = 100 lm/watt, CRI>80, life = 40000 burning hours, PF>0.95 and THD<10%, no UV radiation etc. suitable for ceiling/ wall mounted
289Supply, Installation, Testing and Commissioning of prewired wall/ceiling/false ceiling mounted type following LED lighting fixtures including providing & fixing LED lighting fixtures, electronic drivers,condensers,internal & external reflectors, louvers, etc. Including handling, transportation from owners store to erection site, unpacking, inspection; checking of internal wiring; Erection in position on false ceiling / floor etc ,cable glanding, crimping of lugs and connections at fixtures; supply of all erection materials Including necessary GI hardware, GI clamps, GI brackets, civil masonry materials; all work, labour and materials complete as per drawings, specifications, codes and standards and directions of Engineer in charge.High quality LED tube batten complete with 1X20W tube (T5) eco friendly, having = 2000 lumen output, CCT-6500K, IP-20, luminous efficacy = 100 lm/watt, CRI>80, life = 40000 burning hours, PF>0.95 and THD<10%, no UV radiation etc. suitable for ceiling/wall mounted
290Supply, Installation, Testing and Commissioning of prewired wall/ceiling/false ceiling mounted type following LED lighting fixtures including providing & fixing LED lighting fixtures, electronic drivers,condensers,internal & external reflectors, louvers, etc. Including handling, transportation from owners store to erection site, unpacking, inspection; checking of internal wiring; Erection in position on false ceiling / floor etc ,cable glanding, crimping of lugs and connections at fixtures; supply of all erection materials Including necessary GI hardware, GI clamps, GI brackets, civil masonry materials; all work, labour and materials complete as per drawings, specifications, codes and standards and directions of Engineer in charge. Wall mounted high quality LED tube batten complete with single 9W tube (T5) eco friendly, having = 900 lumen output, CCT-6500K, IP-20, luminous efficacy = 100 lm/watt, CRI>80, life = 40000 burning hours, PF>0.95 and THD<10%, no UV radiation etc.
291Supply, Installation, Testing and Commissioning of prewired wall/ceiling/false ceiling mounted type following LED lighting fixtures including providing & fixing LED lighting fixtures, electronic drivers,condensers,internal & external reflectors, louvers, etc. Including handling, transportation from owners store to erection site, unpacking, inspection; checking of internal wiring; Erection in position on false ceiling / floor etc ,cable glanding, crimping of lugs and connections at fixtures; supply of all erection materials Including necessary GI hardware, GI clamps, GI brackets, civil masonry materials; all work, labour and materials complete as per drawings, specifications, codes and standards and directions of Engineer in charge.Wall/Bracket mounted bulk head lighting fixtures complete with bracket, 9W LED bulb eco friendly, having = 900 lumen output, CCT-6500K, luminous efficacy = 100 lm/watt, CRI>80, life = 40000 burning hours, PF>0.95 and THD<10%, no UV radiation etc. suitable for outdoor installation.
292Supply, Installation, Testing and Commissioning of prewired wall/ceiling/false ceiling mounted type following LED lighting fixtures including providing & fixing LED lighting fixtures, electronic drivers,condensers,internal & external reflectors, louvers, etc. Including handling, transportation from owners store to erection site, unpacking, inspection; checking of internal wiring; Erection in position on false ceiling / floor etc ,cable glanding, crimping of lugs and connections at fixtures; supply of all erection materials Including necessary GI hardware, GI clamps, GI brackets, civil masonry materials; all work, labour and materials complete as per drawings, specifications, codes and standards and directions of Engineer in charge.Round surface mounted 6W LED Down Lighter .
293Wiring
294Point Wiring : One Light / Fan /Exhaust Fan Point shall controlled by one switch .Supply and Providing Point Wiring system for primary light point/ceiling fan point/exhaust fan point/ call bell point/light plug point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size. Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V gradewith 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch, sockets, fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/ Wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate, board, switch, socket etc shall be as per approved Make .(Actual nos. shall be decided at site).
295Point Wiring : TWO Light / Fan / Exhaust FanPoint shall controlled by one switch. Supply and Providing Point Wiring system for primary light point/ceiling fan point/exhaust fan point/ call bell point/light plug point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size. Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V gradewith 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch,sockets,fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate,board switch, socket etc shall be as per approved Make. (Actual nos. shall be decided at site).
296Point Wiring : THREE Light / Fan /Exhaust Fan Point shall controlled by one switch. Supply and Providing Point Wiring system for primary light point/ceiling fan point/exhaust fan point/ call bell point/light plug point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size. Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V gradewith 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch,sockets,fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate,board switch, socket etc shall be as per approved Make. (Actual nos. shall be decided at site).
297Point Wiring : TWIN controlled Light Point.Supply and Providing Point Wiring system for twin controlled lighting point controlled by 1-6 Ampere modular type switch inclusive of the cost for providing circuit wiring from Distribution board to switch boards with 2x2.5 sq.mm.,1.1 KV grade PVC multi stranded fire resistant insulated copper conductor wire for light in required size of rigid PVC conduit with conduit accessories and 14swg bare copper earth wire continuity conductor including providing/fixing of PVC conduit of required size.Item shall also include wiring from switch board to point/fitting with 2x1.5 sq.mm copper conductor PVC insulated wire of 1100V gradewith 14 SWG copper wire as earth continuity conductor for light in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends,JB,sockets etc.required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate for housing modular switch, sockets, fan regulators (Electronic heavy duty step up type) bell push on modular plate etc,The rates shall include cutting and refilling of chases/wall etc. including internal connections as required. All switch sockets shall be modular type fixed on modular plate. Make of modular plate, board switch, socket etc shall be as per approved Make. (Actual nos. shall be decided at site).
298Point Wiring : Plug PointSupply and Providing Point Wiring system for 6A Plug points with single core multi stranded PVC insulated unsheathed copper conductor fire retardant wires of 1100V grade in recessed PVC conduit including providing and fixing PVC conduits of required size complete with accessories such as bends,JB, Pull Boxes etc with plate, switches,sockets,screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable sizes, embedded in wall, concealed and flush with walls including cutting and refilling the chases/ Wall etc and inclusive of 14 SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All Modular type switch & socket shall be of approved make.6 Amp 6 pin socket outlet with 6A switch mounted side by side with 2x2.5 sq.mm PVC copper wire with 14 SWG bare copper earth wire.(Actual nos. shall be decided at site).
299Point Wiring : Secondary Plug Pointfrom Primary Plug Point Supply and Providing Point Wiring system for 6A Plug points with single core multi stranded PVC insulated unsheathed copper conductor fire retardant wires of 1100V grade in recessed PVC conduit including providing and fixing PVC conduits of required size complete with accessories such as bends,JB, Pull Boxes etc with plate, switches,sockets,screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable sizes, embedded in wall, concealed and flush with walls including cutting and refilling the chases/ Wall etc and inclusive of 14 SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All Modular type switch & socket shall be of approved make.6 Amp 6 pin socket outlet with 6A switch mounted side by side with 2x2.5 sq.mm PVC copper wire with 14 SWG bare copper earth wire.(Actual nos. shall be decided at site).
300Point Wiring :Power Plug Point Supply and Providing Point Wiring system for 16A /6A power plug point with following sizes PVC insulated unsheathed single core multi stranded copper conductor, fire retardant wires of 1100V grade in recessed PVC conduits of required size complete with accessories such as bends,JB,Pull boxes etc with plate switches,sockets,screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable size, embedded in wall concealed and flush with walls including cutting and refilling the chases/Wall etc, and inclusive of 14SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All modular type switch & socket shall be of approved make.16A, 6 Pin socket outlet with 16A switch mounted side by side with 2x4 sq.mm PVC copper wire with 14 SWG bare copper earth wire as an independent circuit from DB. (Actual nos. shall be decided at site).
301Point Wiring : Secondary Power Plug Point from Primary Power Plug Point Supply and Providing Point Wiring system for 16A /6A power plug point with following sizes PVC insulated unsheathed single core multi stranded copper conductor, fire retardant wires of 1100V grade in recessed PVC conduits of required size complete with accessories such as bends, JB, Pull boxes etc with plate switches, sockets, screws and covers, Zinc Passivated MS modular boxes (16 gauge sheet construction) of suitable size, embedded in wall concealed and flush with walls including cutting and refilling the chases/Wall etc, and inclusive of 14SWG bare copper earth conductor for socket outlets as per specifications & direction of Engineer in charge. All modular type switch & socket shall be of approved make.16A, 6 Pin socket outlet with 16A switch mounted side by side with 2x4 sq.mm PVC copper wire with 14 SWG bare copper earth wire as an independent circuit from DB. Two nos.power plug point shall be looped from one primary plug point.
302Point Wiring : A.C. Point Supply and Providing Point Wiring system for 32A Industrial socket point (A.C. Point) with 2x4 sq.mm PVC insulated copper conductor FRLS cable in recessed PVC conduit along with 1x4 sq.mm. PVC insulated FRLS cable for earthing I/C, Providing & fixing 25A plug & socket unit complete with 32A DP MCB and 32A plug top including GI Box to be mounted on modular plate complete with connections, testing & commissioning etc (separate circuit for each point):32A DP MCB with Sockets for 1.5T AC
303TV Point
304Supply, providing & drawing point wiring system for co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the surface / recessed in appropriate size of PVC conduit including providing & fixing PVC conduit with accessories such as bends, JB etc. along with TV socket as required. The rate shall include supply and fixing of TV antenna socket outlet (modular type) complete with required size of MS zinc passivated modular box with white inner plate and glossy white outer module plate, modular base, cover plate etc. The rate shall also include cutting and refilling of chases/wall etc, including internal connections as required. All sockets shall be modular type fixed on the modular plate. Make of modular plate, board, switch, socket etc shall be of approved make.
305Supply, hanging, fixing, connectingof f following single phase exhaust fan with guards/ louvers, along with necessary brackets, all required civil works, making good the walls after fixing the fans etc. 300 mm sweep heavy duty exhaust fan with self opening louvers.
306Supply, hanging, fixing, connectingof f following single phase exhaust fan with guards/ louvers, along with necessary brackets, all required civil works, making good the walls after fixing the fans etc.: 450 mm sweep heavy duty Industrial type exhaust fan with self opening louvers.
307Supply, Innstallation, Testing & Commissioning of Call Bell/Buzzer for single phase , 230 V complete as required
308Supply, hanging, fixing, connecting,decorative type, 3-blade ceiling fan including provision of cable/wire from ceiling rose or connector to fan including supply and fixing hexagonal fan hook with 12 mm dia. MS rod bend to shapeas required. 1400 mm sweep
309Supply, hanging, fixing, connecting,decorative type, 3-blade ceiling fan including provision of cable/wire from ceiling rose or connector to fan including supply and fixing hexagonal fan hook with 12 mm dia. MS rod bend to shapeas required. 1200 mm sweep
310Supply, hanging, fixing, connecting,decorative type, 3-blade ceiling fan including provision of cable/wire from ceiling rose or connector to fan including supply and fixing hexagonal fan hook with 12 mm dia. MS rod bend to shapeas required. 600 mm sweep
311Supply, hanging, fixing, connectingof following single phase wall fan , along with necessary brackets, all required civil works, making good the walls after fixing the fans etc. 400 mm sweep heavy duty wall fan with string controlled regulator & rotation.
312Supply, installation, testing and commissioning of interlocked type switch sockets with matching plugs complete with cable glands, lugs, terminal blocks etc. of following ratings: 63A, 5 pin, 415V (Weather Proof)
313Supply, installation, testing and commissioning of interlocked type switch sockets with matching plugs complete with cable glands, lugs, terminal blocks etc. of following ratings:25A, 3 pin, 240V
314LAN & EPABX WORKS (PART - III)
315For All Building"s
3161/2" PVC CONDUIT PIPE
3171" CONDUIT PIPE(6KG/CM2 WORKING PRESSURE )
3182" CONDUIT PIPE(6KG/CM2 WORKING PRESSURE )
3194 x 4" PVC BOX