Tender For Water Supply Project Of 233 Villages (Gangatalai-97 & Anandpuri-136) Of District-Banswara From Jher Anicut Near Terminal Point Of Mahi & Anas River (Kadana Block Water) Under Jal Jeevan Mission - - Intake Well, Wtp & Transmission System Upto Oh, banswara-Rajasthan

Public Health Engineering Department-PHED has published Tender For Water Supply Project Of 233 Villages (Gangatalai-97 & Anandpuri-136) Of District-Banswara From Jher Anicut Near Terminal Point Of Mahi & Anas River (Kadana Block Water) Under Jal Jeevan Mission - - Intake Well, Wtp & Transmission System Upto Oh. Submission Date for this Tender is 16-05-2024. Dam Work Tenders in banswara Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42824702
Corrigendum : Tender For Water Supply Project Of 233 Villages (Gangatalai-97 & Anandpuri-136) Of District-Banswara From Jher Anicut Near Terminal Point Of Mahi & Anas River (Kadana Block Water) Under Jal Jeevan Mission - - Intake Well, Wtp & Transmission System Upto Oh
Open Tender
Indian
Rajasthan
banswara
16-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Water Supply Project Of 233 Villages ( Gangatalai-97 & Anandpuri-136 ) Of District-Banswara From Jher Anicut Near Terminal Point Of Mahi & Anas River ( Kadana Block Water ) Under Jal Jeevan Mission - - Intake Well, Wtp & Transmission System Upto Ohsrs Package-1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Apr-2024 Corrigendum No 1 Date 08-05-2024
2 30-Apr-2024 corrigendum no. 3 Date 16-05-2024
3 30-Apr-2024 corrigendum no. 2 and pri bid clarifications Technical Bid 16-05-2024

Key Value

Document Fees
INR 50000 /-
EMD
INR 45026000.0 /-
Tender Value
INR 225.13 Crore /-

Attachment

FileName File Description File Size
8fb6e939-3567-424a-87bd-6a154ac07de3.html Tender Notice 0 KB
14Drawings.pdf Tender Document 0 KB
14Eproc.pdf Tender Document 0 KB
BOQ_691540.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Water Supply Project of 233 Villages (Gangatalai-97 & Anandpuri-136) of District-Banswara from Jher Anicut near terminal point of Mahi & Anas River (Kadana Block Water) under Jal Jeevan Mission - - Intake Well, WTP & Transmission System upto OHSRs Package-1
Sl. No. Item Description
1Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification.
2300 mm Dia 8 mm thick casing pipe with protective coating.
3Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge.excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately
4100 mm dia
5150 mm dia
6200 mm dia
7300 mm dia
8350 mm dia
9400 mm dia
10600 mm dia
11Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in- charge.(excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
12100 mm dia
13150 mm dia
14200 mm dia
15250 mm dia
16300 mm dia
17350 mm dia
18400 mm dia
19Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
20Note: The rates for DI double flanged pipes shall be reduced 5%, if used other than OHSR pipes.
21100 mm dia
22200 mm dia
23250 mm dia
24300 mm dia
25350 mm dia
26400 mm dia
27450 mm dia
28600 mm dia
29800 mm dia
30Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
31100 mm dia
32150 mm dia
33200 mm dia
34250 mm dia
35Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. For Pump Piping
36100 mm dia 4.0 mm thick
37150 mm dia 4.0 mm thick
38200 mm dia 4.0 mm thick
39250 mm dia 4.0 mm thick
40100 mm dia 6.0 mm thick
41150 mm dia 6.0 mm thick
42200 mm dia 6.0 mm thick
43250 mm dia 6.0 mm thick
44300 mm dia 6.0 mm thick
45450 mm dia 6.0 mm thick
46300 mm dia 8.0 mm thick
47350 mm dia 8.0 mm thick
48450 mm dia 8.0 mm thick
49800 mm dia 8.0 mm thick
50Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.
51In all types of Soils
52upto 1.5 m
53Above 1.5 mtr and up to 3.0 mtr.
54In Soft Rock
55upto 1.5 m
56Above 1.5 mtr and up to 3.0 mtr.
57In Hard Rock (Blasting Required)
58upto 1.5 m
59Above 1.5 mtr and up to 3.0 mtr.
60In Hard Rock (Blasting Probihited)
61upto 1.5 m
62Above 1.5 mtr and up to 3.0 mtr.
63Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, FloatLP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work
64Class PN 1.6
6550 mm dia
6680 mm dia
67100 mm dia
68Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer.
69Air valve pillarfor airvalves sizeupto 80mmdia
70Air valve pillarfor airvalves size of above 80 upto 150mmdia
71Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
7280 mm dia
73100 mm dia
74150 mm dia
75200 mm dia
76250 mm dia
77300 mm dia
78350 mm dia
79400 mm dia
80450 mm dia
81600 mm dia
82800 mm dia
83Providing, lowering, aligning, fixing in position in pipe line at work site, DID/FResilientseated(softseated)SluiceValves(GateValves), Vacuumtight(bubbletight),straightandpocketlessbodypassageof approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of gradeGGG40/GGG50 asper DIN1693 orGR SG- 400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxypowder(EP-P)/ Fusion bond epoxy( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside,DrilledasperIS1538.Nut-Boltconfirmingto IS:1363andIS: 1367 (Galvanisedsteel)InsersionrubberofblackEPDM6mmthick. Suitablesupport structure as per directions of EIC, Sluice valves includingalljointing&jointingmaterial,labour,testingand commissioning along with pipe line as per Technical Specifications and as perdirectionofEngineer-in-charge.Note:Ratesareexclusiveoftail piece/ dismantling joints and earth work. Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 On Individual Delivery Pipe
84100 mm dia
85150 mm dia
86200 mm dia
87250 mm dia
88300 mm dia
89Dismantling Joint
90Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0
9180 mm dia
92100 mm dia
93150 mm dia
94200 mm dia
95250 mm dia
96300 mm dia
97350 mm dia
98400 mm dia
99450 mm dia
100600 mm dia
101Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel)as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer.
102100 mm dia
103200 mm dia
104250 mm dia
105300 mm dia
106350 mm dia
107400 mm dia
108450 mm dia
109600 mm dia
110800 mm dia
111Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
112350 mm dia
113400 mm dia
114450 mm dia
115Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvenised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. At Individual Delivery pipe Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6, Motorised Operated
116800 mm dia
117Construction of Sectionalizing Valve Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge
1181200 mm x 900 mm x 1450 mm (upto 150 mm dia)
1191500 mm x 1200 mm x 1550 mm (upto 350 mm dia)
1202000mm x 2000 mm x 1760 mm (upto 400-500mm dia)
1212500 mm x 2500 mm x 2000 mm (upto 500-800 mm dia)
122Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
123Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ("Original producers" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)
124Shuttering
125Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
126Bituminous courses
127Granular courses
128Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
129Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.
130Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
131M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
132Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
133Providing, installation, testing, trial run and commissioning of the following, as per specifications Supply erection testing and commissioning of pumps and motors of approved duty conditions as per scope of work and specification given in tender document
134INTAKE - CPS-1/WTP route151 LPS / 100 m head/232 KW (2W+2S)
135INTAKE (JHERI) - GAMANA MALA WTP-2 route62 LPS / 105 m head/125 KW (1W+1S)
136CPS-1/WTP - ACL-23 Chhapra - ACL-06 Bhaler Chamna - CPS-5/TPS-03 of 99 LPS/110m head/(1 W +1 S)/200 KW
137CPS-1/WTP - CPS-3 /TPS-01 of 83 LPS/100m head/(1 W +1 S)/160 KW
138CPS-03 /TPS-01 - ACL-04 - ACL-54 - ACL-46 of 16 LPS/75m head/(1 W +1 S)/30 KW
139CPS-5/TPS-03 - MBR-1 KHOONTA NAGARAT of 49 LPS/115m head/(1 W +1 S)/110 KW
140Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
1415.5 KW (7.5 HP)
1429.3 KW (12.5 HP)
14311.0 KW (15 HP)
14418.5 KW (25.0 HP)
145Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.
146Discharge 20 to 30 LPS and head 41 to 50 M
147Discharge 20 to 30 LPS and head 81 to 90 M
148Discharge 31 t0 40 LPS and head 31 to 40 M
149Discharge 31 to 40 LPS and head 81 to 90 M
150Discharge 41 t0 50 LPS and head 61 to 70 M
151Discharge 61 to 70 LPS and head 51 to 60 M
152Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.
153100 mm dia
154200 mm dia
155300 mm dia
156Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR "O "ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel)Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
157200 mm dia
158300 mm dia
159SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
160100 mm dia
161150 mm dia
162200 mm dia
163250 mm dia
164300 mm dia
165400 mm dia
166450 mm dia
167600 mm dia
168Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O "ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
169100 mm dia
170150 mm dia
171200 mm dia
172250 mm dia
173Construction of Flow Meter Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge
174Upto 150 Mm
175Above 150 mm upto 350 mm
176Above 350 mm upto 700 mm
177Design, construction,execution, testing and commissoining of Rapid Gravity Filter treatment plant including all relevant civil, electrical, mechanical, instrumentation automisation and SCADA allied works and stores along with ancillary civil works as defined in scope of works.
178Design & Construction of Rectangular clear water Reservoirs of required capacity at following places, including its piping, fittings, etc complete in all respect as per the scope of work & specifications given in tender document
179Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -
180a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. . b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
181h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k)Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
182Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.
183350 KL capacity
184500 KL capacity
185700 KL capacity
186Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: -
187a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall. e) Successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.
188j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm p) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
189Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M
19050 KL, staging Height 15 m (3-Nos.)
191Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -
192a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e)Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).
193k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
194Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II18 M Staging
195100 KL, staging Height 18 m
196150 KL, staging Height 18m
197200 KL, staging Height 18 m
198250 KL, staging Height 18 m
199300 KL, staging Height 18 m
200Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II20 M Staging
201100 KL, staging Height 20 m
202150 KL, staging Height 20 m
203200 KL, staging Height 20 m
204250 KL, staging Height 20 m
205300 KL, staging Height 20 m
206350 KL, staging Height 20 m
207Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II22 M Staging
208100 KL, staging Height 22 m
209150 KL, staging Height 22 m
210200 KL, staging Height 22 m
211400 KL, staging Height 22 m /MBR-1
212100 KL, staging Height 24 m
213200 KL, staging Height 24 m
214400 KL, staging Height 24 m /MBR-2
215Supply, installation, testing and commissioning of CI Float Valve (Auxiliary type) at Inlet of OHSR/GLSR including all necessary specials required
216100 mm dia
217150 mm dia
218200 mm dia
219250 mm dia
220Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
221Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
222Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.
223Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.
2240 to 1.5 m
2251.5 to 3 m
2263 to 4.5 m
2274.5 to 6 m
228Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available :
229Ordinary rock
2306 to 7.5 m
2317.5 to 9 m
2329 to 10.5 m
233Hard rock (requiring blasting) useful material 30%
23410.5 to 11 m
235Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcementfor :-
236Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.
237M25 grade Design Mix
238Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for :
239Walls (any thickness) including attached pilasters,buttressesplinthandstring course.
240Add extra for shuttering in circular work in plan up to dia 10m over item Nos. 4.7.1 to 4.7.2
241Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.
242Thermo-mechanically Treated bars (Conforming of relevent IS code)
243Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
244M15 grade Nominal Mix (with graded stone aggregate 20mm nominal size).
245Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand
246Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
247M10 grade Nominal Mix (with graded stone aggregate 20mm nominal size).
248Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcementfor :-
249Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases
250Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcementfor :-
251Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.
252Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases
253M20 grade Nominal Mix
254Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for :
255Columns, pillars, posts and struts etc.
256Suspended floors, roofs landings staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam etc.
257Add extra for shuttering in circular work in plan up to dia 10m over item Nos. 4.7.1 to 4.7.2
258Brick masonry in foundation and plinth with bricks of class designation 75 in :
259Add extra over item No.5.1 for brick work in super structure upto third storey.
260Providingandfixingflushdoorshutters non decorative type (hello core construction)withinternelframeofIst grade wood having styles and top rails of 100mm wodth & bottom and lockrails of 150mm width with 3 nos cross battens of 50mm thick width and 12nos 50mm vertial moddle member throughtlength using 4mm thick commercial ply on both faces
261ofshutters&6mmthickbeadingof respective wood using withapproved steel fitting as per annexure A 30mm thick (P No B-8/83 Item No 8.20.1)
262Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
263Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :
26420mm thick .
265Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. All kinds of soil.
266In all types of soils such as moorum, sand, sandy silt, clay, black cotton soil, kankar etc
267Depth of excavation up to 1.5 m
268Depth of excavation above 1.5 m and up to 3.0 m
269Providing and laying in position cement concrete including curing compaction etc . Complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate M15 grade Nominal Mix ( with graded stone aggregate 20mm nominal size)
270Providing and laying in position specified grade of reinforcement cement concrete all RCC structural elements upto plinth level including curing compaction finishing with rendering in cement sand mortar 1:3 ( 1cement : 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement M20 grade (1cement : 1.5coarse sand : 3stone aggregate 20 mm size)
271For Footing
272Providing and laying in position specified grade of reinforcement cement concrete all RCC structural elements upto floor three level including curing compaction finishing with rendering in cement sand mortar 1:3 ( 1cement : 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement M25 grade (1cement: 1 coarse sand : 2stone aggregate)pears abutments posts struts etc.
273Centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formworks for foundation in basement rafts, footings, straps beams, bases of columns etc. up to plinth level.
274Suspended floors, roofs, landings staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blockes sills, chhajjas, lintel, beams etc.
275Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete above plinth level upto 4.5 mtr height. Electric resistance or induction butt welded tubes.
276Supply & fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc for staircase or verandah as per design complete in all respect (Wooden or pVC hand railing to be paid wxtra) with primimng coat of red oxide.
277Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 m, including taking out the excavated soil and depositing and refiling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil.
278Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 m, including taking out the excavated soiland depositing and refiling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50 m.Incuding stacking of useful materia if available. Ordinary rock
279Earth work in excavation over areas ( exceeding 30 cm in depth, 1.5 mtr in width as well as 10 sqm on plan ) incuding disposal of excavated earth lead up to 50 m and lift up to 1.5 mdisposed earth to be levelled and neatly dressed. All kinds of soil
280Earth work in excavation over areas ( exceeding 30 cm in depth, 1.5 mtr in width as well as 10 sqm on plan ) incuding disposal of excavated earth lead up to 50 m and lift up to 1.5 mdisposed earth to be levelled and neatly dressed. Incuding stacking of useful materia if available.
281Ordinary rock
282Hard Rock ( Requiring Blasting ) useful material 30 %
283Hard Rock ( Blasting prohibited ) useful material 30 %
284Providing and Laying in position cement concrete including curing compaction etc complete using stone aggregate 20 mm nominal size in foundation & plinth excluding the cost of centering and shuttering - using M-10 grade mix 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone 20 mm nominal size )
285Providing and Laying in position cement concrete including curing compaction etc complete in specified grade incuding the cost of centering and shuttering - All work up to plinth level. Using crusher broken aggregate 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominall size )
286Random rubble stone masonry for foundation and plinth in cement sand mortar 1:6 for above 30 cm thick wall
287Providing and laying damp proof course with cement concrete grade M-150 ( 1:2:4 ) mortar prepared with 1% solution of water proof compound complete as per specifications without glass strip & hot blown bitumen. 75 mm thick
288Brick work in superstructure up to third storey with selected bricks of class designation 75 in exposed brick work including making horizontal and vertical grooves 10 mm. wide 12 mm deep complete in cement mortar 1:6
289Centering and shuttering with ply wood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of form works for up to floor three level for: Suspended floors, roofs, landing, staircases, balconies, girders, cantievers, bands, copings, bed plates, anchor blocks, sills, chajjas, lintels, beams etc,
290Providing and fabricating steel reinforcement for RCC work including straightening, cutting bending, placing in position and binding ( including cost of binding wire ) all complete up to floor three level.Hot rolled deformed bars (IS:1139)
291Providing and Laying in position specified grade of cement concrete for all RCC structural elements up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand ) and making good the joints excluding the cost of centering, shuttering and reinforcement Beams, suspended floors, roofs, girders having slopes up to 15 0, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases M 20 grade Nominal Mix ( With graded stone aggregate 20 mm nominal size )
292Providing brick kharanja in lime sand mortar 1:2 in square pattern over roof of ground floor. 55 mm to 60 mm thick average
293Add for if cement mortar 1:4 is used instead of lime sand mortar 1:2
294Finishing with 25 mm thick cement plaster on roofs in cement sand mortar 1:4 mix including water proofing compound @ 2 % of cement used, with neat cement, finishing curing etc. complete in all respect including making of 300 mm * 300 mm square.
295P&F 18 SWG MS recessed fan box, hexagonal / round of size 130 mm dia, depth 75 mm, 12 mm dia rod fan hook with 100 mm length extended on each side
296Supplying and fixing in walls machine cut and polished stone shelves, tands and sills in CM 1:3 with machine cut edges:
297Sand or other approved stone 35 mm thick
298Kota stone 25 to 30 mm thick
299Extra over item 6.16.1 to 6.16.6 for machine cut both side polished stone is used.
300Brick work in partition in superstructure 7 cm thick ( brick on edge ) of class designation 75 in cement mortar 1:4
301Half brick masonry in superstructure in cement sand mortar 1:4
302Plaster on new surface of walls in cement sand mortar 1:4including raking of joints etc complete fine finish. 20 mm thick
303Add extra for plaster done over ceiling
304Random Rubble dry stone kharanja under floor
30520 to 25 mm thick polished stone flooring over 20 mm thick base of CM 1:4 ( 1 cement : 4 coarse sand ) and jointed with grey cement slurry including rubbing complete in all respect: Nimbahera Stone
30620 mm thick polished stone for steps risers, skirting, dados, walls & pillars laid on 12 mm thick base of CM 1:3 & jointed with grey cement inclluding rubbing & polishing : Nimbahera Stone
307Providing and fixing Ist quality standard white / Ivory /grey, fuma, red brown, light green, light blue, and other light shade glazed tiles of ( confirmimg to IS : 13753 & IS 13622 ) of size 300 mm * 200 mm in walls, floors, steps, pillars, etc laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete ( excluding the cost of cement plaster on walls & pillars )
308Providing and fixing angle iron frame 25*25*3 mm for ventilators with fixed wire gauge 16 mesh 24 gauge including 100 mm square bars at interval of 100 mm welded screwed to frame with metal beading 20*3 complete in all respect as per design.
309Supplying and fixing fixed wire gauge of 14 mesh * 24 gauge to the metal frame of rolled section by metal beading 20*3 with suitable screw at not exceeding 150 mm distance.
310Providing and fixing square bars or other flat welded to window, ventilators etc.
311Providing and fixing T - iron frames for doors, Windows and ventilators of mild steel Tees sections, joints mitred and welded with 15*3 mm lugs 10 cm long embedded in cement concrete block 15*10*10 cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded aggregate 20 mm nominal size ) or wooden plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a proming coat of approved steel primer.
312Providing and fixing MS sheet double leaf door shutter in angle iron frame 35*35*5 mm suitabilly diagonally braced with 25*3 mm flat iron above and below lock rail of size 50*5 mm beading extra including all fittings, as per direction of Engineer In Charge but excluding cost of chaukhats, including two coats of anti- corrastie red oxide primer paint.MS sheet 18 SWG
313Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade incuding all scaffolding:New work ( two or more coats ) over and including scrapping and priming coat with cement primer.
314finishing wall with water proofing paint of approved brand and manufacture and / or required shade to give an even shade including all scaffolding New work ( three or more coats )
315Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade: New steel work ( two or more coats )
316Part B - Water Supply & Sanitary Fittings
317Construction of Septic Tank in all type of soil with 40 cm thick masonry in CM 1:6, 15 cm thick CC bed of 1:5:10, M-15 grade CC flooring & over stone slab covering 80 mm thick slab jointing in CM 1:3 ranthal, kharanja, 50 mm thick stone partition walls, 20 mmm thick plaster in CM 1:6 finished with neat floating cement, 4 nos. CI foot rests of approved design two no. 450 mm dia 25 kg each CI cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr, Size 200 * 100 * 130 cm ( for 10 users )
318Construction of open surface drain with 112 mm thick brick masonry in CM 1:4,110 mm thick base concrete 1:5:10, 37 mm thick M-15 grade CC flooring 12 mm, 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earth within a lead of 50 mtr complete as per approved design / drawings: 112 mm drain 225 mm Av. Depth
319P&FIndian type white glazed vitreous china Ist quality WC Orissa Pan (IS:2556 mark) with 100 mm vitreous china P or S trap including cutting and making good the wall & floor. Size 530*410 mm
320P&F PVC storage tank ( IS:12701 ) marked indicating the BIS license no. of approved make with cover 25 mm dia 1 M long GI over flow pipe & 25 cm long wash out pipe with plug and socket including making connections etc. complete of approved design. 500 lit
321P&F WVC wash basin ( Ist quality, IS:2556 mark ) of approved make with CI brackets duly painted, 1 no. 15 mm CP pillar cock ( IS:8934 mark ) & 32 mm CP brass waste coupling of approved make, 25 mm dia GI waste pipe complete including cutting & making good the wall: Size 510 mm * 400 mm
322P&F Kitchen & Lab sink of approved make with CI brackets duly painted, 40 mm CP waste coupling, CP brass chain with rubber plug, 40 mm GI waste pipe up to floor level complete including cutting and making good the wall & floor: 1.0 mm thick salem stainless steel AISI - 304 kitchen sink of approved make ( Nirali, Neel-Kanth, Jaina, Faber, Crystal ) with large waste coupling Overall sizes ( Inches ) 24 * 18 * 8 Bowl sizes ( Inches ) 20*16*8
323P&F rigid PVC pipe ( IS: 4985 mark ) class II / ( 4 kg / cm2 ) approved quality / make including jointing the pipe solvent cement rubber ring and lubricant. 110 mm dia
324P&F PVC pipe fittings ( IS : 4985 mark ) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant:
325Coupler ( Socket )
326Bend 450
327Vent Cowl
328Pipe Clip
329P&F grating of approved quality / make Stainless steel heavy quality of approved make 125 mm dia
330P&F Flush Cock / Flush Valve ( IS:9758 mark ) for WC of approved quality / make.exposed 25 mm nominal bore
331P&F Bib cock ( IS:8931 mark ) superior quality of approved make CP Brass bib cock, 15 mm nominal bore
332P&F B Class GI pipes ( Internal work ) with GI fittings ( IS:1239 mark ) & MS clamps including cutting and making good the wall and floors:Exposed on wall
33315 mm nominal dia "A" Class
33425 mm nominal dia "A" Class
335P&F B Class GI pipes ( External work ) with GI fittings ( IS:1239 mark ) including trenching & refilling earth etc. 15 mm nominal dia "A" Class
336P&F Beveled edge mirror of special glass of approved make ( Atul / equivalent ) complete with 6 mm thick asbestos cement sheet ground fixed to wooden screw & washers.Size 600 * 450 mm * 4 mm thick
337P&F towel rail or ring of approved quality / make. CP brass towel rail with brackets 600 * 20 mm
338P&F Tooth paste & brush holder of approved quality / make: stainless steel
339P&F soap dish or tray of approved quality / make. CP Brass ( heavy & superior quality )
340Providing and fixing Anodised Aluminium Curtain rod with Aluminium brackets. 20 mm
341Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade ( IS:694 ) of approved make in surface / recessed ISI marked MMS ( IS:9537 P-III ) PVC conduit & its accessories, round tiles, 18 SWG MS box with earth terminal , Screwless cage connectors for neutral looping in swith board & false ceiling point, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, Zinc plated / brass screws, cup washers, making connections, testing etc as required.
342Short point ( Up to 3.0 mtr )
343Medium point ( Up to 6.0 mtr )
344Long point ( Up to 10.0 mtr )
345Wiring of 3 pin 5 amp light plug point with 1.5 sq mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade ( IS:694 ) of approved make in surface / recessed ISI marked MMS ( IS:9537 P-III ) PVC conduit & its accessories, 18 SWG 175 mm x 100 mm x 60 mm MS box with earth terminal , Screwless cage connectors for neutral looping in swith board , 6 A switch, 6 A Socket, 3.0 mm thick ISI marked phenolic laminated sheet, Zinc plated / brass screws, cup washers, making connections, testing etc as required.
346On Board
347Medium point ( Up to 6.0 mtr )
348Long Point ( Up to 10.0 mtr )
349S&F of power plug ponit accessories on 18 SWG metal box of size 175 * 100 * 60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket out let making connection, testing etc as required.
350P & F 240 / 415 V MCB of breaking capacity not less than 10 KA ( B / C / D tripping characteristic ) ISI marked IS 8828 ( 1996 ) confirming to IEC 60898 in existing board / sheets including making connections with lugs, testing etc as required. Single pole MCB 6 A to 32 A rating
351P & F 240 / 415 V isolator confirming to IS:1497 - III / IEC 60947 - 3 on existing board / sheet including making connections with lugs, testing etc as required. 30 A / 40 A rating
352P&F Recessed / surface mounting heavy duty vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCB / RCCB and SP / TP MCB as out going phophatised / powder painted complete with insulated suitable rating copper bus bar, neutral link earth link,and din bar, masking sheet confirming to IS:13032 & IS:8623 including making internal DB terminations with copper lugs, testing etc. as required. Single door ( Single phase ) 4 way
353Plate earthing as per IS:3043 with GI Earth plate of size 600 mm * 600 mm * 6.0 mm by embodying 3 to 4 mtr below ground level with 20 mm dia GI B class watering pipe including all accessories like nut, bolt, reducer, nipple, wire meshed funnel and CC finished chamber covered with hinged type with locking arrangement CI Cover, CI frame of size 300 mm * 300 mm complete with alternate layers of salt and coke / charcoal, testing of earth resistance as required
354P / Laying XLPE / PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:7098-I / 1554 P-I of group 1 of approved make in ground as per IS:1255 including excavation of 30 cm * 75 cm size trench, 25 cm thick under layer of sand, II class brick covering, refilling earth, compaction of earth, making necessary connection, testing etc as required of size 4.0 sq.mm 3 core
355P&F double ball bearing capacitor start aluminium body & blade Ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required ( Group 1 ) 1200 mm sweep
356P&F of heavy duty capacitor start, double ball bearing 900 /1400 RPM single phase ISI marked Ehaust fan IS:2312 marked in existing opening including making connections testing etc as required.( Group 1 ) 300 mm sweep ( 900 /1400 RPM )
357P&F IP - 43 protected street light luminaire on existing bracket suitable for FTL/T5 lamps,housing made out from stove enamel painted alluminium alloy, stove enamel painted CRCA sheet canopy reflector cum contorl gear tray , UV stabilized clear ribbed acrylic diffuser held with synthetic gasket, min. 6 nos. of toggles for securing acrylic cover with housing with all necessary accessories. ( low loss copper choke, starter, starter seat ) / electronic choke with terminal block duly prewired with copper conductor including making connection, testing etc as required ( without tube ). 1x36 watts
358S&F of street light bracket made out from following size of "B" class GI pipe with heavy duty pole clamp, saddles suitable fastnrs etc as required. 32 mm dia.
359P&F strip type fluorscent tube fitting fabricated from CRCA sheet and finished with powder coating / stove enamelled paint/ extruded non corrosive UV resist EP channel complete with accessories ( low loss copper choke, starter, starter seat ) / electronic choke with terminal block duly prewired with copper conductor including making connection, testing etc as required ( without tube ). 1x36 watts with OCCB
360SITC of Air Cooled split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foampipe section) upto 10 Mtr (IDU to ODU), copper power cable upto 10 Mtr (IDU to ODU), R-22 Refrigerant suitable for 400/230V +10% of 50 Hz 1/3AC supply capable of performing COOLING, DEHUMIDIFICATION, AIR CIRCULATION, FILTERATION & VENTILATION of following capacity with resprocating/ rotary/ scroll compressor as specified. Wall/Ceiling Mounted 1.5 ton
361P&F fluorescent tube rod in existing fixtures as required minimum 3 star rating 36 / 40 watts
362Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion)
363Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
364Centering & Shuttering with plywood or steel sheets including strutting, propping, bracing bothways and removal of formwork for foundations in basements rafts, footings, strap beams bases of columns, etc. upto plinth level.
365Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks
366Cement mortar 1 : 6 (1 cement : 6 coarse sand)
367Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :
368Cement mortar 1 : 6 (1 cement : 6 coarse sand)
369Half brick masonry in foundation & plinth using bricks of designation 75
370Cement mortar 1 : 4 (1 cement : 4 coarse sand)
371Brick work in partition in super structure upto five storey 7cm. thick (brick on edges) using bricks of class designation 75 in :
372Cement mortar 1 : 4 (1 cement : 4 coarse sand)
373Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design. (Clear openable area to be measured for payment).
374Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
375Windows side hung /Ventilators top or centre hung (openable)
376Partly fixed and partly openable [ fixed area not to exceed 33%]
377Brick on edge flooring with bricks of class designation 75 including cement slurry& pointing in CM (1 : 3) etc. complete laid on20 mm thick bed of : Cement Sand Mortar 1 : 6
37860 mm thick cement concrete flooring with Metallic concrete hardener topping, under layer of 42 mm thick cement concrete 1 : 2 : 4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size) and top layer of 18 mm thick metallic concrete hardener consisting of mix 1 : 2 (1 cement : 2 stone aggregate, 6 mm nominal size) by volume & mixed with metallic hardening compound of approved quality @ 3 Kg./Sqm including cement slurry, rounding off edges etc. but excluding the cost of nosing of step etc. complete.
379Cement plaster in skirting and / dado with cement mortar 1 : 3 (1 cement : 3 course sand) finished with a floating coat of neat cement including rounding of junctions with floor :
380Colour washing of all shades to give an even shade including all scaffolding :
381New work (two or more coats) with a base coat of white washing with lime.
382Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
383Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished seamless type tubes.
384P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm
385Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :
386Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect.
387Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure "A" :30mm tick- commercial Veneer Both side
388Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry : Size 100 x 75mm.
389Providing and fixing factory made P.V.C. door frame manufactured by M/s Rajshri of the size 50x47mm with a wall thickness of5mm, made out of extruded 5mm PVC foam sheet mitred at two corners and jointed with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame shall be fixed to the wall using 65/100 mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4 nos of screw to be provided for each vertical member and minimum 2 nos for horizontal member etc. complete as per manufactures specification and direction of Engineer in Charge.
39030mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mmtop & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter).
391Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade ( IS:694 ) of approved make in surface / recessed ISI marked MMS ( IS:9537 P-III ) PVC conduit & its accessories, round tiles, 18 SWG MS box with earth terminal , Screwless cage connectors for neutral looping in swith board & false ceiling point, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, Zinc plated / brass screws, cup washers, making connections, testing etc as required.
392Short point ( Up to 3.0 mtr )
393Medium point ( Up to 6.0 mtr )
394Long point ( Up to 10.0 mtr )
395Wiring of 3 pin 5 amp light plug point with 1.5 sq mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade ( IS:694 ) of approved make in surface / recessed ISI marked MMS ( IS:9537 P-III ) PVC conduit & its accessories, 18 SWG 175 mm x 100 mm x 60 mm MS box with earth terminal , Screwless cage connectors for neutral looping in swith board , 6 A switch, 6 A Socket, 3.0 mm thick ISI marked phenolic laminated sheet, Zinc plated / brass screws, cup washers, making connections, testing etc as required.
396On Board
397Medium point ( Up to 6.0 mtr )
398Long Point ( Up to 10.0 mtr )
399S&F of power plug ponit accessories on 18 SWG metal box of size 175 * 100 * 60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket out let making connection, testing etc as required.
400P & F 240 / 415 V MCB of breaking capacity not less than 10 KA ( B / C / D tripping characteristic ) ISI marked IS 8828 ( 1996 ) confirming to IEC 60898 in existing board / sheets including making connections with lugs, testing etc as required. Single pole MCB 6 A to 32 A rating
401P & F 240 / 415 V isolator confirming to IS:1497 - III / IEC 60947 - 3 on existing board / sheet including making connections with lugs, testing etc as required. 30 A / 40 A rating
402P&F Recessed / surface mounting heavy duty vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCB / RCCB and SP / TP MCB as out going phophatised / powder painted complete with insulated suitable rating copper bus bar, neutral link earth link,and din bar, masking sheet confirming to IS:13032 & IS:8623 including making internal DB terminations with copper lugs, testing etc. as required. Single door ( Single phase ) 4 way
403Plate earthing as per IS:3043 with GI Earth plate of size 600 mm * 600 mm * 6.0 mm by embodying 3 to 4 mtr below ground level with 20 mm dia GI B class watering pipe including all accessories like nut, bolt, reducer, nipple, wire meshed funnel and CC finished chamber covered with hinged type with locking arrangement CI Cover, CI frame of size 300 mm * 300 mm complete with alternate layers of salt and coke / charcoal, testing of earth resistance as required
404P / Laying XLPE / PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:7098-I / 1554 P-I of group 1 of approved make in ground as per IS:1255 including excavation of 30 cm * 75 cm size trench, 25 cm thick under layer of sand, II class brick covering, refilling earth, compaction of earth, making necessary connection, testing etc as required of size 4.0 sq.mm 3 core
405P&F double ball bearing capacitor start aluminium body & blade Ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required ( Group 1 ) 1200 mm sweep
406P&F of heavy duty capacitor start, double ball bearing 900 /1400 RPM single phase ISI marked Ehaust fan IS:2312 marked in existing opening including making connections testing etc as required.( Group 1 ) 300 mm sweep ( 900 /1400 RPM )
407P&F IP - 43 protected street light luminaire on existing bracket suitable for FTL/T5 lamps,housing made out from stove enamel painted alluminium alloy, stove enamel painted CRCA sheet canopy reflector cum contorl gear tray , UV stabilized clear ribbed acrylic diffuser held with synthetic gasket, min. 6 nos. of toggles for securing acrylic cover with housing with all necessary accessories. ( low loss copper choke, starter, starter seat ) / electronic choke with terminal block duly prewired with copper conductor including making connection, testing etc as required ( without tube ). 1x36 watts
408S&F of street light bracket made out from following size of "B" class GI pipe with heavy duty pole clamp, saddles suitable fastnrs etc as required. 32 mm dia.
409P&F strip type fluorscent tube fitting fabricated from CRCA sheet and finished with powder coating / stove enamelled paint/ extruded non corrosive UV resist EP channel complete with accessories ( low loss copper choke, starter, starter seat ) / electronic choke with terminal block duly prewired with copper conductor including making connection, testing etc as required ( without tube ). 1x36 watts with OCCB
410P&F fluorescent tube rod in existing fixtures as required minimum 3 star rating 36 / 40 watts
411Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade ( IS:694 ) of approved make in surface / recessed ISI marked MMS ( IS:9537 P-III ) PVC conduit & its accessories, round tiles, 18 SWG MS box with earth terminal , Screwless cage connectors for neutral looping in swith board & false ceiling point, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, Zinc plated / brass screws, cup washers, making connections, testing etc as required.
412Short point ( Up to 3.0 mtr )
413Medium point ( Up to 6.0 mtr )
414Long point ( Up to 10.0 mtr )
415Wiring of 3 pin 5 amp light plug point with 1.5 sq mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade ( IS:694 ) of approved make in surface / recessed ISI marked MMS ( IS:9537 P-III ) PVC conduit & its accessories, 18 SWG 175 mm x 100 mm x 60 mm MS box with earth terminal , Screwless cage connectors for neutral looping in swith board , 6 A switch, 6 A Socket, 3.0 mm thick ISI marked phenolic laminated sheet, Zinc plated / brass screws, cup washers, making connections, testing etc as required.
416On Board
417Medium point ( Up to 6.0 mtr )
418Long Point ( Up to 10.0 mtr )
419S&F of power plug ponit accessories on 18 SWG metal box of size 175 * 100 * 60 mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket out let making connection, testing etc as required.
420P & F 240 / 415 V MCB of breaking capacity not less than 10 KA ( B / C / D tripping characteristic ) ISI marked IS 8828 ( 1996 ) confirming to IEC 60898 in existing board / sheets including making connections with lugs, testing etc as required. Single pole MCB 6 A to 32 A rating
421P & F 240 / 415 V isolator confirming to IS:1497 - III / IEC 60947 - 3 on existing board / sheet including making connections with lugs, testing etc as required. 30 A / 40 A rating
422P&F Recessed / surface mounting heavy duty vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCB / RCCB and SP / TP MCB as out going phophatised / powder painted complete with insulated suitable rating copper bus bar, neutral link earth link,and din bar, masking sheet confirming to IS:13032 & IS:8623 including making internal DB terminations with copper lugs, testing etc. as required. Single door ( Single phase ) 4 way
423Plate earthing as per IS:3043 with GI Earth plate of size 600 mm * 600 mm * 6.0 mm by embodying 3 to 4 mtr below ground level with 20 mm dia GI B class watering pipe including all accessories like nut, bolt, reducer, nipple, wire meshed funnel and CC finished chamber covered with hinged type with locking arrangement CI Cover, CI frame of size 300 mm * 300 mm complete with alternate layers of salt and coke / charcoal, testing of earth resistance as required
424P / Laying XLPE / PVC insulated & PVC sheathed cable of 1.1 kV grade with aluminium conductor of IS:7098-I / 1554 P-I of group 1 of approved make in ground as per IS:1255 including excavation of 30 cm * 75 cm size trench, 25 cm thick under layer of sand, II class brick covering, refilling earth, compaction of earth, making necessary connection, testing etc as required of size 4.0 sq.mm 3 core
425P&F double ball bearing capacitor start aluminium body & blade Ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required ( Group 1 ) 1200 mm sweep
426P&F of heavy duty capacitor start, double ball bearing 900 /1400 RPM single phase ISI marked Ehaust fan IS:2312 marked in existing opening including making connections testing etc as required.( Group 1 ) 300 mm sweep ( 900 /1400 RPM )
427P&F IP - 43 protected street light luminaire on existing bracket suitable for FTL/T5 lamps,housing made out from stove enamel painted alluminium alloy, stove enamel painted CRCA sheet canopy reflector cum contorl gear tray , UV stabilized clear ribbed acrylic diffuser held with synthetic gasket, min. 6 nos. of toggles for securing acrylic cover with housing with all necessary accessories. ( low loss copper choke, starter, starter seat ) / electronic choke with terminal block duly prewired with copper conductor including making connection, testing etc as required ( without tube ). 1x36 watts
428S&F of street light bracket made out from following size of "B" class GI pipe with heavy duty pole clamp, saddles suitable fastnrs etc as required. 32 mm dia.
429P&F strip type fluorscent tube fitting fabricated from CRCA sheet and finished with powder coating / stove enamelled paint/ extruded non corrosive UV resist EP channel complete with accessories ( low loss copper choke, starter, starter seat ) / electronic choke with terminal block duly prewired with copper conductor including making connection, testing etc as required ( without tube ). 1x36 watts with OCCB
430P&F fluorescent tube rod in existing fixtures as required minimum 3 star rating 36 / 40 watts
431Construction of Septic Tank in all type of soil with 40 cm thick masonry in CM 1:6, 15 cm thick CC bed of 1:5:10, M-15 grade CC flooring & over stone slab covering 80 mm thick slab jointing in CM 1:3 ranthal, kharanja, 50 mm thick stone partition walls, 20 mmm thick plaster in CM 1:6 finished with neat floating cement, 4 nos. CI foot rests of approved design two no. 450 mm dia 25 kg each CI cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr, Size 200 * 100 * 130 cm ( for 10 users )
432Construction of open surface drain with 112 mm thick brick masonry in CM 1:4,110 mm thick base concrete 1:5:10, 37 mm thick M-15 grade CC flooring 12 mm, 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earth within a lead of 50 mtr complete as per approved design / drawings: 112 mm drain 225 mm Av. Depth
433P&FIndian type white glazed vitreous china Ist quality WC Orissa Pan (IS:2556 mark) with 100 mm vitreous china P or S trap including cutting and making good the wall & floor. Size 530*410 mm
434P&FEuropean type white glazed vitreous china Ist quality double syphonic WC Pan ( IS:2556 mark ) with P or S trap including cutting and making good the wall & floor.
435P & F Low level Flushing Cistern of 10 litres capacity ( IS:2556 mark ) of approved make with complete fittings CI brackets duly painted, brass ball cock with ball, ( IS:1703 mark ) complete including cutting and making good the wall: PVC with CP brass long bend.
436P&F PVC storage tank ( IS:12701 ) marked indicating the BIS license no. of approved make with cover 25 mm dia 1 M long GI over flow pipe & 25 cm long wash out pipe with plug and socket including making connections etc. complete of approved design. 500 lit
437P&F WVC wash basin ( Ist quality, IS:2556 mark ) of approved make with CI brackets duly painted, 1 no. 15 mm CP pillar cock ( IS:8934 mark ) & 32 mm CP brass waste coupling of approved make, 25 mm dia GI waste pipe complete including cutting & making good the wall: Size 510 mm * 400 mm
438P&F rigid PVC pipe ( IS: 4985 mark ) class II / ( 4 kg / cm2 ) approved quality / make including jointing the pipe solvent cement rubber ring and lubricant. 110 mm dia
439P&F PVC pipe fittings ( IS : 4985 mark ) of approved quality / make including jointing the pipe with solvent cement rubber ring and lubricant:
440Coupler ( Socket )
441Bend 450
442Vent Cowl
443Pipe Clip
444P&F grating of approved quality / make Stainless steel heavy quality of approved make 125 mm dia
445P&F Bib cock ( IS:8931 mark ) superior quality of approved make CP Brass bib cock, 15 mm nominal bore
446P&F B Class GI pipes ( Internal work ) with GI fittings ( IS:1239 mark ) & MS clamps including cutting and making good the wall and floors:Exposed on wall
44715 mm nominal dia
44825 mm nominal dia
449P&F B Class GI pipes ( External work ) with GI fittings ( IS:1239 mark ) including trenching & refilling earth etc. 15 mm nominal dia
450P&F Beveled edge mirror of special glass of approved make ( Atul / equivalent ) complete with 6 mm thick asbestos cement sheet ground fixed to wooden screw & washers.Size 600 * 450 mm * 4 mm thick
451P&F towel rail or ring of approved quality / make. CP brass towel rail with brackets 600 * 20 mm
452P&F Tooth paste & brush holder of approved quality / make: stainless steel
453P&F soap dish or tray of approved quality / make. CP Brass ( heavy & superior quality )
454P&F Jet spray for water closet with CP copper tube flange of approved make
455Providing and fixing Anodised Aluminium Curtain rod with Aluminium brackets. 20 mm
456Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers androlling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil
457upto 1.5 mtrs
458Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like with pumping set of following H.P. including P.O.L./Power consumption etc. complete.
4595 - 9 HP
460Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. M25
461Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
462Supply, Installation, Testing and commissioning of copper wound ISI markedTransformer11/0.433KV,ThreePhase,50Hz,DYN11, ONANtype,Standardaccessorieslike,conservator,Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Liftinglugs,Bi-directionalPlain/FlangedRollers,Earthing terminal,Air relaese plug.Off load tap changer (+5% to -10% in stepsof2.5%),winding/Topoiltemperatureriseof45°C/40°C,ISImarked drain valves, Dial type temperature gauge, first fill oil, Epoxy basedpaintetchavingmax.totallossesasperenergyefficiency level-2atbasicInsulationlevelconformingtoIS2026(Part-Ito Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level -IasperGovt.ofIndia,MinistryofpowernotificationDated16th Dec.,2016.Transformersdescribedasaboveandasperthe following continuous rating
463160KVA
464200KVA
465250KVA
466315KVA
467750KVA
4681000KVA
469ProvidingandlayingXLPE/PVCinsulated&PVC sheathed armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction
4703C x 2.5 sq.mm
4718C x 2.5 sq.mm
472Supply , Installation, Testing and Comissioning of Outdoor / Inddor Fix TypeICOG 11 KV, 630A, 20 KA / 1 Sec. HT VCB Panel with AL. Bus bar. comprising of 11KV FIXED TYPE VCB,630A, 20 KA with associated Protection duly fabricated with 2/1.6 mm CRCA Sheet, powder coated, Colour RAL 7032/35/AR complete with hardware and instruments duly wired & tested with stand structure.Protection Class: IP5X. Incoming cum Outgoing facility (ICOG). Suitable for Indoor & Outdoor Application (IP 54).Panel with approvedmake Fix Type VCB 630A, suitable for 30000 Operation. This Panel having Voltage Presence Indications. Panel having Protection O/C, S/C & E/F Relay with RS 485 Communication Port. Panel having Protection for WTI, OTI & BZ. Panel having Annunciation Window for visual & Hooter.Panel having Lifting Facility (4 Lifting Hooks). Panel having Stand Structure (500 mm) in Bottom for easy Installation & Cable Termination. For Control Supply One Power Pack with battery backup provided for continuous control supply. Required Protection (MCB,s) & Indication are provided. PLC & SCADA compitible.
473SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries , MS / Teakwood battery stand , interconnect wiring etc as required complete in all respect of rating:
474110VDC
475SITCofFCBC ( Floatcumboostcharger)suitable for415V +/-10%, 50 Hz , 1-? / 3 -? Input &24/ 48/110 VDC OutputNatural Cooled, freestandinginSheetSteelenclosure,SCRcontrolled,regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,BuiltinDCDistributionBoard(6NoMCB),indication,controlas required of following rating:
47625 A + 25 A
477Earthing Schedule Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 40 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
478Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mmx6.0mmbyembodying 3 to 4mtr.below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andC.C.finished chamber covered with hinged type with locking arrangement C.I.Cover,C.I.Frameofsize300mmx300mmcompletewith alternate layers of salt and coke/charcoal, testing of earth resistance as required.
479S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
48050mm x 6mm copper strip
48150mm x 6mm G.I. Strip
48232mm x6mm G.I. Strip
48325mm x 3mm G.I. ( Hot Dipped) Strip
484Providing&LayingXLPEinsulatedIS:7098/II/85of approvedmakeH.T.cableforworkingvoltage11 K.V.Un-EarthedwithStrandedCompactedCircular AluminiumConductor,ConductorScreenedwith ExtrudedSemi-conductingcompound,XLPEInsulated, InsulationScreenedwithextrudedsemi-conductingcompoundincombinationwithCopperTape,coreslaid up,innersheathofThermoplastictape,galvanisedflat steel strip armoured and overall Extruded PVC Type ST-2OuterSheathedcabledirectingroundincluding excavationof30cmx100cmsizetrench,25cmlayerof riversand, second Class bricks covering, refilling earth, compactionofearth,makingnecessaryconnection testing etc.as required of size.
4853 core 120.0 Sq.mm
486Providing&makingheatshrinkabletypeindoor/outdoor/straight throughterminations/jointkitofapprovedmakesuitableforXLPEinsulated11KVcable,withrequiredcomponents,preprationof cable ends,testing etc. as required of following sizes .
487Indoor
4883 core 120/150/185 Sq.mm
489Outdoor
4903 core 120/150/185/225 Sq.mm
491Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection,Complete as per technical specifications and as directed by Engineer in charge.
492120 SQMM, 3.5 CORE
493300 SQMM, 3.5 CORE
494400 SQMM, 3.5 CORE
4954.0 SQMM, 3.5 CORE
49610.0 SQMM,3 CORE
49725.0 SQMM, 3 CORE
49835.0SQMM, 3 CORE
49970.0 SQMM, 3 CORE
50095.0 SQMM, 3 CORE
501150.0SQMM, 3 CORE
502185.0SQMM, 3 CORE
503240.0SQMM, 3 CORE
504Supply,Fabricating&installingfollowingsizesofladdertypecable trays with rungs at span of 250 mm including horizontal and vertical bends,reducerstees,crossmembersandotheraccessoriesas requiredand dulysuspended from the ceiling/wall withsuspenders and including painting as required.
505Hot Dipped Galvanized
506450mm x 50mm x 2.0mm
507600mm x 50mm x 2.0mm
508Supply,Fabricating&installingfollowingsizesofperforatedcable traysincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended from the ceiling withsuspenders and including painting as required.
509Hot Dipped Galvanized
510100mm x 50mm x 1.6mm
511150mm x 50mm x 1.6mm
512300mm x 50mm x 1.6mm
513450mm x 50mm x 2.0mm
514Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the matwith synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR . 11 KV, 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage45 KV
515415 V LT PanelSITCoffloormountedPMCC(Indoor,DustproffIP-4Xfront operatedwith2mmthicksheetmetalompartmentalised)withall accessibleparts,headshrinkablesleeves,SMC/DMCbusbar supports, padlocking facility on outgoing feeders etc.
516Incommerfeederfor(drowouttype)transformer1600A,50KA, ACB3pole,AlBusBars,DigitalMultifunctionmetercompatableto SCADA,metering,ProtectionCT"s,IDMT3-O/C&1-E/F,indicating lamps,controlfuse,wiringetc.completeinallrespectofthesize appxo 900(D)X.2400(H)X1000(D)
517BusCouplerFeeder(drowouttype),1600AACB,50KA,3Pole withoutreleasewithAlBusBars,IndicatingLamps,ControlFuses andwiringetc.completeinallrespect.Size:900(W)x2400(H)x 1000 (D)
518400 A MCCB Incomer (Fixed type )with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS, IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D)
519250 A MCCB Incomer (Fixed type ) with metering CTs, multi fuction meter compatible to scada, Ampermeter with SS, Voltmeter with SS,IndicatingLamps,ControlFuse,wiringetc.completeinallrespect. Size:900(W)X600(H)X1000(D)
520MCCB up to 100A(Fixed type ) as outgoing CT"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D)
521MCCB up to 100A(Fixed type ) as outgoing CT"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D)
522MCCB up to 100A(Fixed type ) as outgoing CT"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D)
523MCCB up to 100A(Fixed type ) as outgoing CT"s, Ampermeter with SS,VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)300(H)X1000(D)
524250AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D)
525630AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)X900(H)X1000(D)
526630AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)X900(H)X1000(D)
527250AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 900(W)600(H)X1000(D)
528160AMCCB(Fixedtype)asoutgoingCT"s,AmpermeterwithSS, VoltmeterwithSS,IndicatingLamps,ControlFuse,wiringetc. complete in all respect.Size: 600(W)600(H)X1000(D)
529SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus.
53075KW
531110KW
532160KW
533250KW
534S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ControlMCBwithpanelwithallaccessorieswithfollowing rating
5357.5 KW to 9.3KW
53611KW
53718.5KW
53822 KW
53930KW
54055KW
541433V APFC Panel in cubicle made of CRCA sheet steel of minimum 2.5/2.0/1.6 mm thickness, comply with latestIEC 61439-1-2020, totally enclosed Operational on 3 Phase 415 voltages, 50Hz, neutrally grounded, IP 55, The cubicle panel shall be vermin proof and dust-tight and shall be of compartmentalized type construction, nine tank pre-treatment process before powder coating, Paint Shade – Grey RAL 7032, gasket material- neoprene, AC/DC/CT wiring – 1.5/2.5sqmm PVC insulated multi strand Copper flexible wire, Heat shrinkable Colour coded PVC bus bar sleeves, cable entry Incoming – bottom and outgoing – Bottom as per requirement. The switchgears and control gears complete with all necessary supporting framework, nuts and bolts, Aluminum Bus Bar. The Indoor APFC Panel switchesgear (Air circuit breakers, MCCB, CTs, etc) and control gear (Microprocessor based APFC 8/12 Stage relays, APFC Duty Contactors, auxiliary contacts, Space heater and lighting, Digital A & V meters with Selector Switch, Phase Indications, Hooter, plug socket etc.) shall be mounted on the same panel Complete as per technical specifications and as directed by Engineer in charge.
542SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.
543Local Push Button Station
544SupplyanderectionofOctagonalpoleoffollowing lengthand dimensionas per table-3 withbaseplateon thecementconcretefoundationofM-15/M-20grade (1:1.5:3)withthehelpofanchorboltsofgrade6.8(IS 1367PIII).ThepoleshallbemadeofS-355JOgrade steelsheet,foldedlengthwisetoobtainedOctagonal shape,havingsinglelongitudinalseamweldandhot dippedgalvanisedinternally&externallyinaccordance withIS2629.Thepoleshallhaveaweatherproofflush doorandlockingarrangements.Thecompletework shallbesupervisedandcertifiedbythemanufacturers forsatisfactorysupply,erection,testingand commissioning.
5457 Mtr.
546Supply,ErectionandFixingofhotdippedgalvanised Overhang (60 X 3.25 mm) with cap (250 x 137.9 x 4.05 mm) over the poles
547Single arm overhang
548P/FIP-65/IP-66protectedstreetlightluminarieson bracket / Arm.Fixturemadefrompowdercoated singlepiecepressurediecastaluminumhousingwith heat dissipation fins on housing with high power LEDs . Diffuser/glasscoverforensuringIP-65protectionfor lampandcontrolgearcompartment,systemlumen outputof100lum/watthighpowerLED.Integrated drivershallbehighefficiencyhavingefficiencymore than 85 % and in compliance to IEC standards. System lifeof50000burninghourswith70%ofinitiallumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries
549LED street light fixture 80-90 watt
550P&FIP-65protectedintegralfloodlightluminaire suitableforHPSV/Metalhalidelampcomprisingof powdercoateddiecastaluminiumhousing, electrochemicallybrightenedandanodizedstippled aluminium reflector, covered with suitably gasketed heat resistant and toughened glass, porcelain holder, integral controlgearboxhavingcopperballast,capacitor, electronicignitorprewiredwithpvcinsulatedcopper conductoruptoterminalblockincludingmaking connection testing etc.
5511 X 250 Watt
552P&FHighpressuresodiumvapour/Highpressure mercuryvapour/Metalhalide/Halogenlampas required. HPSV tubular lamp normal output.
553250 Watt
554Providing and fixing in position lightening arrester set complete with 600mm x 600mm x 6mm thick G.I. earthing plate embedded below ground in earthling pit at 3.5 metre depth, G.I. strip of size 25mmx5mm thick from earthing plate to top of Over head tank, G.I. Finial made of GI bar 25mm dia and 2m long fixed on top of Building and connected to GI strip. The earthling set shall comply of IS:3043 complete in all respect as per specification and the direction of the Engineer.
555From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W)x400 (H) x 600 (D)
556Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements.
557Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Electrical Taps, HT Tap, Danger Plates, First Aid box complete with all standard medical , 4.5 Kg. CO2 type portable fire extinguisher , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per requirements.
558Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI –92 num DO – 92 num AI –16 num AO – 8 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 30 num Selector Switch - 15 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 30 num Wiring + TB etc – 1 lot Hardware – 1 lot
559Design,manufacture,supply,installation,testingand commissioning of indoor type PLC panel of size approx. 1100 mm X 700 mm X 2100mm (LBH) , fabricated out of min.2mmthickCRCAsheetcompletewithlatest configurationPC,necessaryprogrammingforSCADAsoftware and comprising of all accessories not limited to the following: DI – 60 num DO – 60 num AI – 8 num AO – 4 num MCB 10A DP – 1 num MCB4ADP – 2 num MCBSP2A – 8 num MCB 1A DP – 15 num 24 VDC Power Supply 10A – 1 num Push Buttons – 20 num Selector Switch – 10 num Control Relays – 200 num Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with Electronic Hooter – 1 num Control Transformer- 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num Panel Light with Door Switch – 1 num Control Indication Lamp – 20 num Wiring + TB etc – 1 lot Hardware – 1 lot
560HMI Display, Colour, 15" having Ethernet Port, USB Port ect.
561Operator StationPC SET includes,Corei5processor,8GB DDR-3RAM,1TBSSD,DVDRWDrive,RS-232/485Ports,1ParallelPort,4nos.USBPort,2x EthernetCards,Keyboard,opticalmouse,32""LED monitor, Latest Original window, MS Office, Anti Virus ect.
562Quad-bandGSM/GPRSmodemwithEthernetbridge/ router/ serial server (RS232/485) interface.
563Providing,installation,testingandcommissioningof UPS, 3Phase 415 V, 50 Hzwith 60 min back up Ni+Cd battery bank.
5642KVA
5653KVA
5661.5 Tons Split Type Air Conditioners with auto switch over circuit
567ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup togetheroverallpolyestertapedAl(innersheetedGI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steelArmouredoverallPVCsheathed(ST-1) overallscreenedCoreArmouredinstrumentation Cables generally confirming to PAS 5308- Part-2-2009.
5681 SQMM, 12 Core
5691 SQMM, 24 Core
570ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair Armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
5711 SQMM, 1 Pair
572ProvidingandlayingXLPE/PVCinsulated&PVC sheathed Armoured control cables of 1.1KV gradewith copper conductor as per IS 1255 including excavation of 30CmX75Cmsizetrench25Cmthickunderlayerof sandandsecondclassbrickscovering,backfilling& compaction.
5734C x 2.5 sq.mm
5744C x 1.5 sq.mm
575Providing, Installation, Testing and Commissioning of ULTRASONIC LEVELTRANSMITTER for WaterApplication : Principle :Timeof Flight/ Sensor MOC PP / Process Connection1 1/2 inchBSP or 2 inchBSPThreadedtype/PowerSupply:24VDC/Output:4- 20mA/Display:IntegraldisplayforprogrammingandDisplay Reading/ IP 66
5760-5M
5770-8M
578Providing,Installation,TestingandCommissioningofPRESSURE TRANSMITTERforWaterApplication:Range:0-10Bar/Power Supply:24VDC/Output:4-20mAwithHART/Diaphragm: SS316L/ProcessConnection:1/2"NPT(M)/Accuracy:0.15%Protection: IP67
5791/2" M (NPT)
580Providing,installation,testingandcommissioningofDiaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass,Overrangeprotection:125%ofmaximumpressure,Material ofsensorandotherwettedparts:SStype316,Housingmaterial: Die cast aluminum
581Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC
582Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes:(i)Rigidforlengthsofupto3 meters(ii)Flexibleforlengthsabove3meters(Rigidprobes preferred), Probe insulation: Teflon, Probe head protection class: IP 65ofIS13947PartI,Probeheadhousingmaterial:Aluminum
583Providing,installation,testingandcommissioningofCapacitance LevelTransmitterfortank/sumplevelAccuracy:±1.5%ofspan, Probetype:Rod,Probematerial:SStype316,WeatherProtection Class:IP65ofIS13947PartI,Output:4-20mADC(Isolated), Materialofwettedparts:SS316,Probeinsulationmaterial:Teflon, Stilling pipe: SS type 316 with perforations
584Providing,Installation,TestingandCommissioningofCHLORINE ANALYSER for WaterApplication: Transmitter : Range:0.05to 20 ppm,Power Supply230VAC, Input:2 Digital Sensors - onefor chlorineandsecondforpH,Output:4-20mAHART,IP66/67 Protection / Tx protection coverrequired / Sensor Range 0-14pH , ableto transmit digital signalto transmitter, calibration datacan be transferredtoTransmitter,processtemp:65degcen/Sensor range:0.05 to 20 mg/l
5850.05 -20 mg/l
586Providing,Installation,TestingandCommissioningofTURBIDITY ANALYSER for WaterApplication : Turbidity Measuring range: 0 to 100NTU;Accuracy:+/-2%ofreadingor+/-0.02NTU;Compliance toUSEPA180.1,Withinbuilttransmitterwith4-20mAoutput, Relay contacts & Modbus communication
5870 - 100 NTU
588Providing,Installation,TestingandCommissioningofpH ANALYSER for WaterApplication :Transmitter : Range:0-14pH, PowerSupply230VAC,Input:OneDigitalSensor,Output:4-20mAHART,IP66Protection/Txprotectioncoverrequired/ SensorRange0-14pH,abletotransmitdigitalsignalto transmitter,calibrationdatacanbetransferredtoTransmitter, process temp: 65 deg cen/ flow through teeMOC SS
5890-14 pH
590Supply of GSM /GPRSbased data transmitter/ Data Logger for Bulk Flowmeter installed at VTC Inlet side (woltman Pulse Output only ), Battery Powered -7.4V,battery life 3-5 Years,(1 no Data transmit in aday),4-20mA From Pressure RS485 Display-16*2 LCD,Encloser-165*120*65 mm,ABS Protection-IP65,Operating tempreature -55 Deg. C
591Modular RTU for ESR complete with DI, DO, AI and modbus communication ports and power supply 24 VDC or for variable power supply using batteries, rechargeable batteries, solar or 10.8 V DC to 28.8 V DC with VPN modem (3G/4G/5G) ; connection to control center via Tele Control Basic,DNP3,IEC60870-5-104andCommunicationprotocols,on-board I/Os min. (8 DI, 4 DQ, 2 AI), configuration and diagnostics per webinterface,RJ45port,mobilecommunicationsantenna (GSM/UMTS),MiniSIMcard,withadapterMicroSIMcardalso, GPRS (Multi-slot Class 10), 35 mm DIN rail mounting, TCP/IP, DNP 3, Open VPN-Client. Panel Enclosure for RTU Location, wall/floormountedalongwithwiringandrelatedaccessoriesand arrangement of mounting of RTU, Modem having IP-55 outdoor Protection with canopy. Power supply arrangement shall be Solar Based along with Solar Batteries & Solar Invertors suiatble for applicable. RTU application software (multiusers) shall be provided for pump houses, MCC, and Jal Dhara Commond centre at Jaipur Jal Bhawan.
592Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document.
593Cost for basic service charges, Administration and Management, running of office, staff quarters, comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, IEC activities as per scope of work, cost of material required for maintenance & repairs, cost of lubricants, saltf for producing chorine, consumables spare parts (if the spare parts supplied to PHED are used in emergency) as per scope of work & items & conditions of contract no, amt will be paid for O&M in DLP
594For the 1st year of O&M after DLP
595For the 2nd year of O&M after DLP
596For the 3rd year of O&M after DLP
597For the 4th year of O&M after DLP
598For the 5th year of O&M after DLP
599For the 6th year of O&M after DLP
600For the 7th year of O&M after DLP
601For the 8th year of O&M after DLP
602For the 9th year of O&M after DLP
603For the 10thyear of O&M after DLP
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail