Tender For Annual Repair Of Division Office Pwd B And R Barnala, barnala-Punjab

Public Works Department-PWD has published Tender For Annual Repair Of Division Office Pwd B And R Barnala. Submission Date for this Tender is 18-03-2024. Building Work Tenders in barnala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42823258
Tender For Annual Repair Of Division Office Pwd B And R Barnala
Open Tender
Indian
Punjab
barnala
18-03-2024

Tender Details

Annual Repair Of Division Office Pwd B And R Barnala

Key Value

Document Fees
INR 2000 /-
EMD
INR 15000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Annual Repair of Division Office PWD B and R Barnala.
Sl. No. Item Description
1CIVIL WORKS
2Dismantling glazed tiles (to be carefully removed).
3Dismantling cementconglomerate floors 25mm to 50mm thick without Concrete base
4Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by theanufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ).
5Anti-skid floor tiles 10mm thick in flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with white cement slurry in joints including corners angles and beading.
6Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 100 x 200 mm, 200x200 mm & 200x300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
7Renewing glass panes with putty and nails wherever necessary Glass panes weighing 10.75 Kg/sqm
8Wrought iron and mild steel grating grills etc.
9P/F hydraulic door closer
10PH Works
11Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C Manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket type A.
12110mm o/d single socket SWR UPVC pipe line laid complete
1375mm o/d single socket SWR UPVC pipe line laid complete
14Providing and Fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as IS- 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
15For 110mm i/d pipes
16Elbow 90 Degree (All side socketed)
17Coupler
18Single Tee With Door
19For 75mm i/d pipes
20Coupler
21Floor Trap 110mm x 75mm
22With 75mm i/d outlet deep seal at Ground Floor
23Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm X 150mm, cover and frame clear opening 300 mm X 300 mm and out of side size 330 mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50 mm.
24100mm internal Diametre S.W.Gully trap with H.C.I grating and cost iron cover weighing approximately 7.26 kg and frame clear opening 300mm x 300mm and out of side 330mm x 330mm
25Construction of brick masonry inspection chambers size as given below upto 0.50 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 (150 mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with floating coat of 1 mm thick of neat cement, R.C.C 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm X 610mm inside R.C.C inspection chamber cover and frame (Weight as per I.S.I specifications) Painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
26450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal.
27Providing and laying, jointing, fixing and testing ISI Marked UPVC pipe Lines as per ISI 4985-2000 including specials such as tees, bend, sockets, elbow etc cutting testing (including cost of specials) in the ground complete in all respects.
28uPVC Pipe 6 Kgf/cm2 50mm i/d
29CONCEALED IN WALL: providing and fixing chlorinated polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
30CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
31CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
32CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
33Cutting chase in brick walls in cement or in floor for embedding G.I or C.I pipes line and making good the same to its original Condition. Size 75mm x 75mm
34Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
35Providing, Fixing and Jointing G.I Union Couplings ( of approved make with the approval EIC) as per IS 1879 in G.I Pipe lines complete in all respects.
3615mm i/d G.I. Union
3720mm i/d G.I. Union
3825mm i/d G.I. Union
39Painting G.I Pipes and Specials with synthetic enamel Paint in all shades as per I.S.I specification on existing or new work, two coats paints including cleaning rubbing surface etc.
4015mm & 20mm i/d G.I. Pipe
4125mm & 32mm i/d G.I. Pipe
42Providing and fixing in position Chinaware European type water closet P trap or S Trap of approved make (to the approval of the Engineer-in-charge) Consisting of 10 ltr PVC cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Detail attached as per Table-3
43Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Detail attached as per Table-3
44Providing and fixing jet spray with 2"-6" long PVC pipe. With PTMT nut
45Providing & Fixing in position C.P Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge) Complete in all respect.
46Providing and Fixing in position vitreous chinaware white Iindian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-Charge) Consisting of C.P brass Urinal waste coupling dome type 32 mm outer length 75 mm, C.P brass Urinal Spreader Ocular-Regular and C.P Brass tube connection 300 mm long complete.
47Providing and Fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
48Providing & fixing in position of PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) Complete in all respect. PVC tube connection of Size 15mm x 375mm with PTMT nut
49Providing and Fixing P.V.C Waste Pipe Collapsible 32mm complete in all respect.
50Providing and Fixing in position towel rails/ring of approved make (to the approval of Engineer-in-Charge) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
51Providing and Fixing in position C.P brass soap dish of approved make (to the Approval of Engineer-in-Charge) fixed into wall with rawl plugs and C.P brass screws complete in all respects
52Providing and Fixing in position of 15mm i/d bib cock of approved make (to the approval of Engineer-in-Charge) complete in all respect.
53Providing and Fixing in position stop cock / Angle valve of approved make (to the approval of Engineer-in-Charge) Complete in all respect.
54C.P.brass 15mm Concealed stop cock with flange For Jet Spray Connection + Over Head Shower
55Providing and Fixing in position C.P Brass flange Dome of approved make (to the approval of Engineer-in-Charge) under various fixtures complete in all respects.
56Providing and Fixing in position C.P Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-Charge) with various fixtures complete in all respect. C.P Brass extension piece, 25mm long to 50mm long
57Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of
58Providing and fixing in position premium range C.P. Brass Fittings and accessoriesof approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
59Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. Aluminium khunti with 3 pegs
60Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks
61Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod andPlastic Ball
62Brass Ball Cock with rod andPlastic Ball 32mm i/d
63Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
64G.I. tank nipple 25mmi/d
65Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-
66Automatic Voltage Stablizer 4 KVA
67Providing & Installing & Erection split type wall mounted air conditioner capacity 2tonne 3 Star with MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of 3mtr Copper pipes within building and installing charges complete in all respects
68Copper Wire for AC
69Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
70110 mm o/d pipes
71For Sewer Line GT to IC 6mtr each
72160 mm o/d pipes
73IC to IC
74Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards,fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works,upto one chain (15m) complete in all respects.
75For depthexceeding 3.0 m but not exceeding 3.0 m B.G.L. For all classes of soil except rocky
76For Sewer Line 100 mm dia as per Detail attached
77For Sewer Line 150 mm dia as per Detail attached
78Sand Filling
79For covering Sewer Line Type II
80For Sewer Line 100 mm i/d (Type-I) as per Detail attached
81For Sewer Line 150 mm i/d (Type-I) as per Detail attached
82Extra for making connections of all sizes newly laid sewers within benching of fully charged sewers including pluging of sewer, dewatering & desilting of manholes etc. complete in all respects.
83with existing sewer of 300 mm id and below
84Electrical Works
85Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
86Wiring 6Amp. Plug control comprising wall socket point
87Wiring 16/20Amp. power plug control point
88Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) andmodular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
89Wiring AC supply terminal point having1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
90Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
91Wiring Computer terminal point having 2 Nos. 6Amp. 2/3 universalsocket (shuttered), 1No. 16/20Amp. universal Socket (shuttered) and 2Nos. 16/20Amp. switch with indicator (Modular accessories).
92Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
93Overall size 1.5sq.mm (Un-sheathed)
94Overall size 2.5sq.mm (Un-sheathed)
95Overall size 4sq.mm (Un-sheathed)
96Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materialsetc., as per PWD General Specifications:-
97Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
98Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specificationsincluding connections with suitable size of thimbles/lugs:-
99MCB Single Pole 6-32amp. (10kA, Curve-C)
100MCB Double Pole 40amp. (10kA, Curve-C)
101Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mountingminiature circuit breakers/ RCBO"s/ RCCB"s in the distribution board (For SP&Ndistribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&Nhorizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
102SP&N Double Door Distribution Board 4 way each
103Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
104Overall size 10sq.mm (2Core) Un-armoured (Loose)
105Supply and erection of LED batten 40 Watt LED (including constant LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary.