Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited-UPRVUNL has published Tender For Construction Of Multistorey Residential Buildings For Township At 2X660mw Jawaharpur Thermal Power Project, Malawan, Distt- Etah. Submission Date for this Tender is 09-05-2024. Building Work Tenders in etah Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42818204
Corrigendum : Tender For Construction Of Multistorey Residential Buildings For Township At 2X660mw Jawaharpur Thermal Power Project, Malawan, Distt- Etah
Open Tender
Indian
Uttar Pradesh
etah
09-05-2024

Tender Details

Construction Of Multistorey Residential Buildings For Township At 2X660mw Jawaharpur Thermal Power Project, Malawan, Distt- Etah

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Mar-2024 Clarification on Financial Bid Financial Bid 10-04-2024
2 10-Apr-2024 Extension of Date and Time Date 22-04-2024
3 22-Apr-2024 Date Corrigendum Date 02-05-2024
4 29-Apr-2024 Correction in BOQ Unit Financial Bid 02-05-2024
5 02-May-2024 Date Extension Corrigendum Date 09-05-2024

Key Value

Document Fees
INR 17700 /-
EMD
INR 10500000.0 /-
Tender Value
INR 104.93 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF MULTISTOREY RESIDENTIAL BUILDINGS FOR TOWNSHIP AT 2X660MW JAWAHARPUR THERMAL POWER PROJECT, MALAWAN, DISTT- ETAH
Sl. No. Item Description
1CIVIL WORK
2Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
3DEPTH -0.00 TO 1.50 MTR.
4DEPTH -1.50 TO 3.00 MTR.
5DEPTH -3.0 TO 4.5 MTR.
6Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
7DEPTH -0.00 TO 1.50 MTR.
8DEPTH -1.50 TO 3.00 MTR.
9Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
10Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
13Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
14All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
15All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
16R.C.C. WORK IN COLUMN
17STILT FLOOR
18FIRST FLOOR
19SECOND FLOOR
20THIRD FLOOR
21FOURTH FLOOR
22FIFTH FLOOR
23SIXTH FLOOR
24SEVENTH FLOOR
25EIGHTH FLOOR
26NINTH FLOOR
27TENTH FLOOR
28ELEVENTH FLOOR
29TWELTH& THIRTEEN FLOOR
30TERRACE
31R.C.C. WORK IN SLAB
32STILT FLOOR
33FIRST FLOOR
34SECOND FLOOR
35THIRD FLOOR
36FOURTH FLOOR
37FIFTH FLOOR
38SIXTH FLOOR
39SEVENTH FLOOR
40EIGHTH FLOOR
41NINTH FLOOR
42TENTH FLOOR
43ELEVENTH FLOOR
44TWELTH& THIRTEEN FLOOR
45TERRACE
46R.C.C. WORK IN LINTEL
47STILT FLOOR
48FIRST FLOOR
49SECOND FLOOR
50THIRD FLOOR
51FOURTH FLOOR
52FIFTH FLOOR
53SIXTH FLOOR
54SEVENTH FLOOR
55EIGHTH FLOOR
56NINTH FLOOR
57TENTH FLOOR
58ELEVENTH FLOOR
59TWELTH& THIRTEEN FLOOR
60TERRACE
61R.C.C. WORK IN BEAM
62STILT FLOOR
63FIRST FLOOR
64SECOND FLOOR
65THIRD FLOOR
66FOURTH FLOOR
67FIFTH FLOOR
68SIXTH FLOOR
69SEVENTH FLOOR
70EIGHTH FLOOR
71NINTH FLOOR
72TENTH FLOOR
73ELEVENTH FLOOR
74TWELTH& THIRTEEN FLOOR
75TERRACE
76Extra for RCC /BMC/RMC work above floor (vi-ix) level
77Extra for RCC /BMC/RMC work above floor (x-xii)level for each four floors or part thereof
78Centering and shuttering including strutting, propping etc. and removal of form for :
79Foundations, footings, bases of columns, etc. for mass concrete
80Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
81Suspended floors, roofs, landings, balconies and access platform
82Lintels, beams, plinth beams, girders, bressumers and cantilevers
83Columns, Pillars, Piers, Abutments, Posts and Struts
84Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
85Shelves (Cast in situ)
86Stairs, (excluding landings) except spiral-staircases
87Weather shade, Chajjas, corbels etc., including edges
88Under 20 cm wide
89Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
90Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
91STILT FLOOR
92FIRST FLOOR
93SECOND FLOOR
94THIRD FLOOR
95FOURTH FLOOR
96Add Extra for Brick work/AAC Block masonary/Tile brick masonary in super structure above floor Vth level, for each fourfour floors or part thereof.by mechanical means.
97FIFTH FLOOR
98SIXTH FLOOR
99SEVENTH FLOOR
100EIGHTH FLOOR
101Add Extra for Brick work/AAC Block masonary/Tile brick masonary in super structure above floor Vth level, for each fourfour floors or part thereof.by mechanical means.
102NINTH FLOOR
103TENTH FLOOR
104ELEVENTH FLOOR
105TWELTH& THIRTEEN FLOOR
106TERRACE
107Add extra for brick /AAC block masonary /tile brick masonary in super structure above floor vth level for each floors or part thereof by mechanical means
108for floor x to terrace
109Proving & injecting chamical emulsion for preconstructional anti-termite treatment and creating a chemical barrier under& alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall & floor along the external perimeterofbuilding expansion joints surrounding of pipes & coduits etc.complete plinth area of the building at ground floor only shall be measured as per I.S.63/3( part II 1981 )Aldrine emlsifiable concentrate or any other approvedmaterial suchas Htrachlore or Chlordance will beused . Therateof application ofchemicalemulsionshallbeasfollows:
110(VI) Treatment of soilunder Apron along external perimeter 5litres/sqm
111Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.(Angle iron 35X35X5MM)
112Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. including ISI marked Stainless Steel butt hinges with necessary screws,Steel Handles, Sliding bolt, Door stopper and tower bolt Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On both side only
11335 mm thick
114Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
115Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
116French Spirit polishing. Two or more coats including a coat of wood filler .
117Providing and fixing factory made uPVC white colour casement/casemen cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc.
118Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, allcomplete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
119Three track three panels sliding door made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension.
120Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
121Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
122Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of atching shade complete.
123Supply and fixing Mosquitos proof jail having 5 mesh each cm. Made of 24 B.WG wire heavy quality and including cost of 25x5 mm flat iron around the jali, welding etc comlete.
124Providing & Fixing of window made of pre painted steel ( base Steel as per IS -513of 0.58 mm thick " D" quality galvanizedas per IS 277 with Zink of 120 GSM ) primer coated with epoxy primer of 5-7 microns thick , finish painted with a polyester paint of 12 -16 microns thick and back coatedwith 5-7 microns thick alkyd backer .section of outerframe should be of72 x 55 mm , centre mullion should be of72 x 50 mm , section for fixed glass beadingshould be of12 x 12 mm and sectionfor shutter should be of47 x 20 mm , outer frame and mullion section to have rebate forglazed shutters , flymesh shutters and 20 mm provision for gaurd bars / grill fly mesh shutters section should be of 20 x 40 mm. The section are to be cut to length mitre jointed with corner bracket , centre mullion to be fixed with mullion cap .Elixir or equivalent stay, handles 2nos of heavy dutystain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm squareguard bars with 6” (152.4mm) pitch, complete forfinish item of work
125Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.,complete.
126with lean concrete600x600 mm size tiles
127Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
128Size of Tile 600x600 mm
129Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. FLOORING
130Providing edge moulding to 18 mm thick granite stone ,including machine polishing to edge to give high glossy finish etc .complete as per design approved by engineer -in-charge
131Kota stone slab flooring over 20 mm (average)thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab ,including rubbing and polishing complete with base of cement mortor 1:4 (1 cement :4 coarse sand )-25 mm thick
132kota stone slab 20mm thick in risers of steps skirting ,dado and pillars laid on 12 mm thcik average cement mortor 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete
133Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen sinkin kitchen platfometre, vanity counters and similar location in marble / granite/stone work including necessary holes for pillar taps etc. including rubbing and polisheg of cut edges etc. complete.
134Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
13515 mm cement plaster on rough side of single of single or half brick wall with cement mortor of mix upto 10 mtr height from ground level )
13612 mm cement plaster on brick work with cement mortor of mix (upto 10 mtr height from ground level)
13712 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
138STILT FLOOR
139FIRST FLOOR
140SECOND FLOOR
141THIRD FLOOR
142FOURTH FLOOR
143FIFTH FLOOR
144SIXTH FLOOR
145SEVENTH FLOOR
146EIGHTH FLOOR
147NINTH FLOOR
148TENTH FLOOR
149ELEVENTH FLOOR
150TWELTH& THIRTEEN FLOOR
151TERRACE
15215 mm cement plaster on brick work with cement mortor of mix (upto 10 mtr height from ground level)
15315 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
154STILT FLOOR
155FIRST FLOOR
156SECOND FLOOR
157THIRD FLOOR
158FOURTH FLOOR
159FIFTH FLOOR
160SIXTH FLOOR
161SEVENTH FLOOR
162EIGHTH FLOOR
163NINTH FLOOR
164TENTH FLOOR
165ELEVENTH FLOOR
166TWELTH& THIRTEEN FLOOR
167TERRACE
1686mm cement plaster on ceiling including chipping of CC /RCC surface before plastering in cement mortor of mix 1:3 (1 cement :3 fine sand )(not less than in 1.25 FM)
169STILT FLOOR
170FIRST FLOOR
171SECOND FLOOR
172THIRD FLOOR
173FOURTH FLOOR
174FIFTH FLOOR
175SIXTH FLOOR
176SEVENTH FLOOR
177EIGHTH FLOOR
178NINTH FLOOR
179TENTH FLOOR
180ELEVENTH FLOOR
181TWELTH& THIRTEEN FLOOR
182TERRACE
183Extra for plastering exterior walls of height more than 10 m from ground level for evey additional height of 3 m or part there of.
184Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete including cost of all material ,labourT&P etc complete required for proper completion of the work
185Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
186Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
187Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
188Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :
189Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
190IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
191IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
192IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
193Making drip course in sun shades or facia as per direction of Engineer incharges supply of all materials , labour T&P etc. for proper completion of the work.
194Making Plinth protection 50mm thick of cement concrete 1:3:6(1 cement:3 coarse sand : 6 graded stone aggregate 20mm nominal size)over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
195Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
196Laying of I shaped precast interlocking tiles of thickness 60-100 mm compressive strength not less than 30 mpa and weight 4.5 kg including 25 mm thick local sand base leveling and dressing of surface to required level and slope .and filling joint with local sand all complete work .
19760 mm ordinary Grey
198Supply and filling of cinder in sunkan portion of toilet kitchen etcas per engineer in charge
199Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
200Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm
201Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm
202Providing and fixing aluminium handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete
203Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
204Providing and fixing aluminium hanging floor door stopper, ISI marked , anodised transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper
205Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
206Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
207With float glass panes of 8 mm thickness (weight not less than 20 kg/ sqm)
208Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge.
209Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 12 mm thick
210Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws.
211Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.
212Triple strip vertical type
213Providing and fixing chromium plated brass handles with necessary screws etc. complete:
214100 mm
21575 mm
216Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.
217Size 40 mm
218Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
219Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.
22010 x 120 mm
221Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
222Steel work welded in built up sections/ framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
223Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer
224Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
225Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
226Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
227Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
22862 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardeningcompound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
229S/F Chequerred precast cement concrete tiles 22 mm thick in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed cement mortar 1:4 including preparation of 50 mm thick base with concrete 1:4:8 as per E/I
230Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement
231Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
232Providing and fixing ball bearing for rolling shutters
233SUBHEAD-I (A): SANITARY INSTALLATIONS
234Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required
235White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
236Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required
237W.C. pan with ISI marked white solid plastic seat and lid
238Providing and fixing C.P. brass health faucet with 8mm dia 1m long PVC tube and wall hook complete in all respects.all complete as directed by Engineer-in-chargAs per Griha Requirment
239Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, includingpainting of fittings and brackets, cutting and making good the wallswherever required
240White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
241Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete
242Flexible Pipe
24340 mm dia
244Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
245Rectangular shape 453x357 mm
246Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
247510x1040 mm bowl depth 200 mm
248Providing and fixing PTMT Bottle Trap for Wash basin and sink.
249Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
250Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
251Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms
252Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931
253Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
25415mm nominal bore
255Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.
25615 mm nominal bore
257Providing and fixing toilet paper holder :
258C.P. brass
259Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and
260Granite Stone of approved shade
261Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
262150 mm diameter
263SUBHEAD-II(A): INTERNAL DRAINAGE INSTALLATIONS
264Providing and fixingcast iron trap of self cleansing design withcast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
265100 mm inlet and 100 mm outlet
266Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
267Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
268Providing, jointing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 - Type B) and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints. Pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with 75 mm thick cement concrete (1:2:4) all around. The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications.
269100 MM
270Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) exposed on wall.
27132 mm nominal outer dia pipes
27240 mm nominal outer dia pipes
27350 mm nominal outer dia pipes
274Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality
27532 mm nominal outer dia pipes
27640 mm nominal outer dia pipes
27750 mm nominal outer dia pipes
278Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
279110 mm diameter
280Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
281Coupler
282110mm
283Bend 87.5°
284110 mm diameter
285Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
286110 mm
287SUBHEAD-III(A): WATER SUPPLY INSTALLATIONS
288Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work -Exposed on Wall
28915 mm nominal outer dia pipes
29020 mm nominal outer dia pipes
29125 mm nominal outer dia pipes
292Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc.Roof Work
29325 mm dia, nominal bore
29432 mm dia, nominal bore
295Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality
29625 mm dia, nominal bore
29732 mm dia, nominal bore
298Providing and fixing brass stop cock of approved quality (20mm)
299Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)
30015mm nominal bore
30120mm nominal bore
302Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
30320 mm nominal bore
304Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
305Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mm copper earth continuity wire& modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash.
306Wiring point for two way light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wireand two no two way modular type switchws & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash
307Wiring point for fan/fresh air fan (light duty exhaust/ Ceiling fan) with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable inthick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wire & modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash.
308Wiring point for plug with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wire& modular typeswitch & socket etc complete in all respects including matching color wash.
309Wiring point for call bell with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in thick PVC conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 1.5 Sq.mmcopper earth continuity wire& modular type bell push or 2 pin socket etc complete in all respects including matching color wash
310Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
311Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work.
312Supply and fixingof 6 Amp to 32 Amp. SPMCB (10 KA) C Curve (CAT-A)
313Supply & wiringofsubmainwithFRLSH P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugethick PVC coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects.
3142 x 1.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit.
3152 x 2.5 sq. mm. with 1.5 sq.mm earth wire In 20 mm dia conduit.
3162 x 4 sq. mm. with 2.5 sq. mmearth wire In 25mm dia conduit.
3172 x 6 sq. mm.with 4 sq. mmearth wire In 32mm dia conduit.
3182 x 10 sq. mm. with 6 sq. mmearth wire In 32mm dia conduit.
3192 x 16 sq. mm.with 10 sq. mmearth wire In32mm dia conduit.
3204 x 6 sq. mm. with 2 x 4 sq. mmearth wire In 32mm dia conduit.
3214 x 10 sq. mm.with 2 x 6 sq. mmearth wire In 32mm dia conduit.
3224 x 16 sq. mm. with 2 x 10 sq. mmearth wire In 32mm dia conduit.
323Supply fixing and concealing 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS no 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid, plastering with cement sand mortar finised to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of work. (for Telephone / Television / circuits)
32420 mm dia. conduit (16 SWG) thick
32525 mm dia. conduit(16 SWG)thick
32632 mm dia. conduit(16 SWG)thick
327S/F of surface/flush mounting SPN distribution board with additional metal door without MCBcompletein all respect as directed at site by Engineer-in-charge..
3288 WAYS ( CAT A )
32912 WAYS ( CAT A )
330S/F of surface/flush mounting TPN distribution board with additional metal door without MCBcompletein all respect as directed at site by Engineer-in-charge..
3318 WAYS ( CAT A )
33212 WAYS ( CAT A )
333S/F of 40 Amp DP MCB (10 KA) ( CAT A )
334S/F of 63 Amp TP MCB (10 KA) )( CAT A )
335S/F of surface/flush mounting 6 ways V TPN distribution board with additional metal door without DPX3 160 mccbcompletein all respect as directed at site by Engineer-in-charge. (Cat A)
336S/F of surface/flush mounting 8 ways V TPN distribution board with additional metal door without DPX3 160 mccbcompletein all respect as directed at site by Engineer-in-charge. (Cat A)
337S&F of 100 Amp 4 pole MCCB (25 KA) Thermal Magnetic release
338S&F of 125 Amp 4 pole MCCB (25 KA) Thermal Magnetic release
339Eraction and testing of ceiling fan and regulator for room height upto 3.5 meters including including supply of 3mm thick GI pipe 19mm dia, Duly painted, completed in all respect.
340Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects.
341S/F of hexagonal fan box with hexagonal/ round GP Fan box of approved make made up of 1.0 mm thick ISI marled GP sheet spot welded four to eight holes of 25.4 mm for pip[e entry of the box. Holes should be semi shuttered tyupe with 0.5 mm GP sheet made upper & lower cover duly screwed fitted with 300mm round zink coated MS bar X 12mm & brand name should be embossed.Fixing withwiringconduit laid in the R.C.C.roofbeforeconcreting along with supply of all materials,labour, T&P etc. for proper completion of work.
342Supply & fixing ofelectronic Fanregulator,dimmer, 120-280 VISI marked, ontheexisting switch board includingmaking connections, required material,labourT/Petc.for proper completion ofwork to the satisfaction of Engineer of work.
343S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I rules.
344Supply and laying of aluminium conductor PVC insulated amoured served sheathed cables 1100 Volts grade at depth of 750mm below ground level over a cushion of 75mm. Thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable respect. The armouring of the cable shall be properly connected with the earth conductor by clamps. etc.
34550 sq.mm 3.5 core
346Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.
34750 sq.mm 3.5 core
348Supply and erection of 400 Amp. TPN Rising Mains complete with top end cover plate etc. On angle iron wall brackets complete in all respect.
349Supply and erection of 600 Amp. TPN Rising Mains complete with top end cover plate etc. On angle iron wall brackets complete in all respect.
350Supply and erection of incoming adopter box for mounting 400 Amp. TPN CFS unit including connectors of required capacity on to the rising Mains complete in all respect.
351Supply and erection of incoming adaptor box formounting 630 Amp. TPN CFS unit including connectors of required capacity on to the risingmains complete in all respect.
352Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length upto 2000mm, outer pipe 50mm, inner pipe 25, terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization upto 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducting the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I. strip with be extra) Make: As approved in U.P.P.W.D., & C.P.R.I Certified.
353Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete in all respects as approved by Engineer-in-charge.
354Supply and fixing of vertical air termination final rod comperising of 300mm long x 25 mm dia. Coper rod with one one pointed prong and 100mm dia x 3 mm thick base plate etc complete in all respect.
355As in item 713(A) but for three or four storyed buildings
356As in item 713(A) but for five and above storyed buildings
357Supplying & Layingof 25mm x 3mm. G.I. strip for earthing purpose as required complete in all respects.
358Supply and fixing of one number 8 SWG G.I. wire in 15mm dia G.I. pipe for earthing, laid in ground or in wall duty concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.
359Supply and fixing of recess/surface/ Pendent mounting round 6 Watt to 8 Watt LED Down Lighter having Powder coated die cast aluminiumhousing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. ( CAT - AAA )
360Supply and fixing of recess/surface/ Pendent mounting round 10 Watt to 15 Watt LED Down Lighter having Powder coated die cast aluminiumhousing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. ( CAT - AAA )
361Supply and fixing of LED tube light with batten suitable for uo to 1 x 22 watt LED tube light fitting including tube on surface completein all respect. (CAT - AAA)
362Supply and fixing of single LED light wall bracket 3 to 6 watt on matching M.D.F.E.G Board base etc. completed in all respects. ( CAT - AAA )
363Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP65 as above Protection . complete in all respect.( CAT AAA )
364Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc. as required
3651 or 2 Module (75mmX75mm)
366Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required
367Telephone Socket outlet
368TV Antenna socket outlet
369Supply and drawing followingpair, 0.5 sq.mm. FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required
3701 Pair
371Supply and drawing co-axial TV cable RG-6 grade, 0.7 mm. Solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel/ PVC conduit as required.
372Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes.
373Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required..
374250 mm dia
375Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc as required.
376Providing, fixing, connecting & testingof Telephone Tag Block krone type in asuitable size 1.6 mm thick dust and vermin proof Sheet steel enclosure duly painted by synthetic enamel over anti corrosive primer, lockable and hinged cover with provision for cable through glands complete in all respects.
37710 pair Tag Block
37820 pair Tag Block
37950 pair Tag Block
380100 pair Tag Block
381Supplying, laying, testing and commissioning of following size anealed tinned copper conductor PVC insulated and sheathed armoured copper telephone cables 0.5mmwith suitable clamps, saddles and including making terminal joints complete as required
38210 pair
38320 pair
38450 pair
385100 pair
386Supply of AC230/250 volts, 50 HZceiling fanwith standarddownrod, blades, 2 nos. caps & regulator etc. ISI marked complete as required.
3871200 mm sweep, 50W, 350 RPM
388Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame and other accessories etc.complete
389250 mm sweep 1250 rpm
390Supply of AC230/250 volts, 50 HZ Wall fanincluding providingnuts, bolts, mounting frame and other accessories etc.complete
391400 mm sweep 1350 rpm
3922 Nos.40A 10kA,TPN MCB
393Incoming (Item description similar to Floor Meter board) 1 no. 100A-125A, 415V, Ics=25 kA, 4P MCCB’s with variable overcurrent andvariable short circuit releases & each complete LSIG.3 nos. cast resin current transformers of 125/5 ratio with 15 VA Burden & Class 1.0 for metering.1 Set of (0-500 volts) digital voltmeter with 2 Amps MCB and Digital Ammeter with Built in selector switch.1- set Red/Green ON/OFF indicating lamps1- set of three phase (red, yellow, blue) indicating lamps Amber healthy trip indicating lamps 1 nos MFMBus BarsElectrolytic high conductivity Aluminium three phase and neutral busbars rated at 160 A having a maximum current density of 1.0 A per sq mm suitable to with stand symmetrical fault level of 25kA at 415 V.Outgoings1 Nos. 63/40A 10kA,TPN MCB with 3-phase meter as per EB.2 Nos.40A 10kA,TPN MCBThe switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required (1 Nos 3-phase meter in Panel)
394Incoming (Item description similar to Floor Meter board)1 no. 100A-125A, 415V, Ics=25 kA, 4P MCCB’s with variable overcurrent andvariable short circuit releases & each complete LSIG.3 nos. cast resin current transformers of 125/5 ratio with 15 VA Burden & Class 1.0 for metering.1 Set of (0-500 volts) digital voltmeter with 2 Amps MCB and Digital Ammeter with Built in selector switch.1- set Red/Green ON/OFF indicating lamps 1- set of three phase (red, yellow, blue) indicating lamps Amber healthy trip indicating lamps 1 nos MFMBus BarsElectrolytic high conductivity Aluminium three phase and neutral busbars rated at 160 A having a maximum current density of 1.0 A per sq mm suitable to with stand symmetrical fault level of 25kA at 415 V.Outgoings6 Nos. 63/40A 10kA,SPN MCB with 1-phase meter as per EB.2 Nos.40A 10kA,TPN MCBThe switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required (6 Nos 1-phase meter in Panel)
395Incoming (Item description similar to Floor Meter board)1 no. 100A-125A, 415V, Ics=25 kA, 4P MCCB’s with variable overcurrent andvariable short circuit releases & each complete LSIG.3 nos. cast resin current transformers of 125/5 ratio with 15 VA Burden & Class 1.0 for metering.1 Set of (0-500 volts) digital voltmeter with 2 Amps MCB and Digital Ammeter with Built in selector switch.1- set of three phase (red, yellow, blue) indicating lamps Amber healthy trip indicating lamps 1 nos MFMBus BarsElectrolytic high conductivity Aluminium three phase and neutral busbars rated at 160 A having a maximum current density of 1.0 A per sq mm suitable to with stand symmetrical fault level of 25kA at 415 V.Outgoings8 Nos. 63/40A 10kA,TPN MCB with 3-phase meter as per EB.2 Nos.40A 10kA,TPN MCBThe switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required (8 Nos 3-phase meter in Panel)
396Supply & laying (Including hume pipe/HDPE pipe 50mm dia PN-4, PE-63, Directly in ground, wall) of 12 Cores single mode outdoor 9 micron outoor Fiber cable in existing pipeand cable shall comply with EIA/TIA 5688.2-1/5688.3, ISO/ IEC 11801:2002, ICEA-696, EN50173 Standards as Guided by Engineer-In charge.
397Supplying, installation, testing and commissioning of Varifocal Dome: 4 MP Dome Camera with 1/2.7” CMOS Lens. Minimum Illumination of 0.04 lux @ F2.2, AGC ON 0 lux with IR ON with S/N Ratio >50dB & Electronics Shutter Sensor speed 1/25 s ~ 1/ 100,000 s. Camera should support an IR range upto 30 Meters and a lens size of 2.8-12mm Motorized Focus Zoom type with inbuilt Microphone & SD Card Slot ( Including 256 GB SD Card) . For Recording Purpose camera should support H.265 and below compressions with 3 streams. Camera should be On-Vif type with Profile support S & G. Cameras should be weather proof type with IP67 & Metal Housing & Operating temperatureworking capacity from -30 to +60 degree. Certification – CE, FCC, RoHS.
398Supply and installation of Cat 6 UTP patch cord, 1 mtr
399Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
400Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
401Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S.sounder with facility to make announcement, mounted in A.B.S.box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
402Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
403Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections,interconnections as required.
4046 Zone
40510 Zone
406Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 Zone panel for fire alarm system 100 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communicationsuitable for 20 Nos.talk back unit -1 set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 set. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc.complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch- 1 No.Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos.12 volt, 30 AH each sealed maintenance free batteries -1 set.
407Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupleretc. as required.
408Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
4092 x 1.5 sq. mm
410Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
41120mm
412Supply, installation, testing & commissioning of lift of following capacities and type suitable for operation on 415 V, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency type, with / withoutmachine room, Suitable speed, electromagnetic brake system, simple operations, operating control panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to EPABX, infrared ray sensing door protection for full height,reverse phase relayon controller, fireman’s switch at ground floor, ARD system, operation and maintanance contract of same OEM for 1 year.
413Digital car positions indicator in car and at all positions indicator in car and at all floors with Up/DOWN direction, all signal fixtures in stainless stell faceplates, light fixtures, ventilation fan, etc complete with all accessories includingautomatic rescue device in the event of power failure etc., Complete with necessary scaffolding, electrical panel, logic control panel and shaft lighting etc required for the erection of the elevators as required.
414Machine Room Type (MR) Type with the traction motor placed in Lift Topp (suitable as per cpwd specification, simplex full collective operation with/without attendant. Car/Hoistway Entrance, protected by stainless steel hairline doors and clear center /side opening min as per site. 13 Pasanger Lift, suitable car size Inside dimensions and entrance at front side on all the serving floors, provided with matt finish stainless steelpanel on all four sideand ceiling, stretcher protection on three sides complete as per requirment.
4157 stops & 7 openings ,Total travel height is approximately 22-30M, Speed 1.5 MPS
41613 stops & 13 openings ,Total travel height is approximately 40-45M, Speed 1.5 MPS
41714 stops & 14 openings ,Total travel height is approximately 45-50M, Speed 1.5 MPS
4189 stops & 9 openings ,Total travel height is approximately 29-35M, Speed 1.5 MPS
419Machine Room Type (MR) Type with the traction motor placed in Lift Topp (suitable as per cpwd specification, simplex full collective operation with/without attendant. Car/Hoistway Entrance, protected by stainless steel hairline doors and clear center /side opening min as per site. 15 Pasanger Lift, suitable car size Inside dimensions and entrance at front side on all the serving floors, provided with matt finish stainless steelpanel on all four sideand ceiling, stretcher protection on three sides complete as per requirment.
4207 stops & 7 openings ,Total travel height is approximately 22-30M, Speed 1.5 MPS
42113 stops & 13 openings ,Total travel height is approximately 40-45M, Speed 1.5 MPS
42214 stops & 14 openings ,Total travel height is approximately 45-50M, Speed 1.5 MPS
4239 stops & 9 openings ,Total travel height is approximately 29-35M, Speed 1.5 MPS
424FIRE FIGHTING
425Fire Extinguisher, ABC Type Capacity 4 kg, ISI Marked IS: 15683 (Stored Pressure)
426Fire Extinguisher, CO2 Type Capacity 4.5 kg, ISI Marked IS: 15683 (Make- Exflame)
427Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
42825 mm dia
429100 mm dia
430Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
431Single headed Stainless steel
432Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts,washers, gaskets conforming to IS 13095 of following sizes as required :
433100 mm dia
434150 mm dia
435Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
436150 mm dia
437Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
438Stainless Steel (Grade 304)
439Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.
44020 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
44140 m
442Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable fornstantaneous connection to interconnect hose pipe coupling as required :
443Stainless Steel (Grade 304)
444Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
445Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.
446100mm dia
447Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
448150 mm width x 50mm depth x 1.6 mm thickness.
449Providing and fixing MS partly glazed single/double hung lockable shutter fabricated from MS section as required with5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man"s axe, fire extiguishers 2 nos, including suitably mounted on a raisedmasonry platform as required. (Approx.size 0.90 m x 2.1m )
450Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
451Fire Extinguisher, ABC Type Capacity 4 kg, ISI Marked IS: 15683 (Stored Pressure)
452Capacity 4.5 Kg.
453Fire Extinguisher, CO2 Type Capacity 4.5 kg, ISI Marked IS: 15683 (Make- Exflame)
454Capacity 4.0 Kg.
455Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
456Suitable cement concrete foundation duly plastered and with anti vibration pads.
457900 lpm at 35 m Head
458450 lpm at 35 m Head
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail