Supply Of Various Type Of Test Kits And Consumables For Microbiology Dept. , Dengue Rapid Test For Detecting Ns1 Antigen & Igg & Igm Antibody. • Should Be Capable Of Detecting Dengue Infection From Day-1 & Should Be Preferably Capable Of Detecting All 04 Serotypes Of Dengue Virus. • Should Have High Sensitivity And Specificity And Positive Control. , Ra ( Latex Agglutination Test ) - • Should Be Preferably Ce Marked / Certified. • Reagent Should Be Calibrated Against Who International Standard. • Latex Particles Coated With Purified Human Gamma Globulin. • Should Have With Positive Control , Crp ( Latex Agglutination Test ) • Should Be Preferably Ce Marked / Certified. • Latex Particles Coated With Anti-Human Crp. • Should Have With Positive Control. , Aso ( Latex Agglutination Test ) • Should Be Preferably Ce Marked / Certified. • Latex Particles Coated With Purified Streptolysin O. , Hbsag Rapid Test • Should Be Capable Of Detecting Preferably All Subtypes Of Hbsag. • Lateral Flow Through Technology. • Antigen Sensitivity Should Be Around 0.5Ng / Ml. • Should Have With Positive Control. • Note:- Sensitivity & Specificityshould Preferably Be >99% , Anti Hcv Rapid Test- • Lateral Flow Through Technology. • Should Be Capable Of Detecting Preferably All Subtypes Of Hcv. • Note:- Sensitivity & Specificityshould Preferably Be >99% , Rapid Malaria Antigen Card Test • Based On Pldh For Pv & Hrp-2 Detection For Pf I.E. • Should Be Pv & Pf Specific. • Should Preferably Be Developed According To Who Guidelines & Hence Approved. , Widal Slide Test • Stabilized Reagent For Long Shelf Life ( 18 Months Or More At 2 To 8 Oc. ) • Available In 5Ml Vials Separately Salmonella O, Salmonella H, Salmonella A ( H ) & Salmonella B ( H ) . • Should Be Preferably Ce Marked / Certified. , Upt Card Test , Rpr Slide Test • Should Be Preferably Ce Marked / Certified. • Ready To Use Reagent. • Positive Control Provided With Kit. • Stabilized Reagent For Long Shelf Life ( 18 Months Or More ) • Specimen Can Be Plasma / Serum Can Be Used Without Heat Inactivation. • Preferably Calibrated To Who Reference Serum For Serodiagnostic Test For Treponemal Infection. , Brucella ( Rose Bengal Test ) • Should Be Preferable Ce Marked / Certified. • Positive Control Should Preferably Be Supplied Along With Kit. • More Than 12 Months Reagent Shelf Life At 2 To 8 Degree C. , Scrub Typhus Rapid Card Test • Long Shelf Life ( More Than 18 Months At 2-30 Oc ) • Lateral Flow Through Technology. • Sensitivity & Specificityshould Preferably Be >99% , Dengue Ns1 Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Dengue Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Dengue Igg Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Scrub Typhus Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Scrub Typhus Igg Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hav Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hev Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Brucella Iggelisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Brucella Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Chikungunya Rapid Card Test. • Based In Sandwich Immunoassay Principle. • High Sensitive & Specific. • More Than 12 Months Shelf Life. , Chikungunya Igm Elisa Test. • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hbsagelisa Test. • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hcvelisa Test. • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hiv ( Rapid Tests Of Two Different Types Based On Different Principles ) • 4Th Generation Test For Differential Detection Of P24 Antigen & Hiv-I & Ii Antibody. Flow Through Technology & Interpretation Time Around 5 To 10 Minutes, Approved & Evaluated By Niv / Nari And Who ( Naco ) . • Test For Detecting Both Antigen & Antibody Of Hiv By Examination Of Whole Blood / Plasma / Serum. Should Be Who / Naco Approved. • Note:- Sensitivity & Specificity Should Preferably Be >99% , Syphilis Rapid Strip / Card Test , Leptospirosis Igg Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Leptospirosis Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Leptospirosis Rapid Card Test , Fungal Marker 1-3 Beta-D-Glucan Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Fungal Marker Galactomannan Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Anti Echinococcal Igg Antibody Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Toxoplasma Igg Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Toxoplasma Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Rubella Igg Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Rubella Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Cmv Igg Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Cmv Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hsv Igg Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hsv Igm Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Salmonella Typhi Rapid Card Test For Detecting Both Igg & Igm Antibody. • Long Shelf Life ( 18 Months Or More At 2 To 30 Oc. ) • Should Have High Sensitivity And Specificity And Positive Control. , Sars Cov-2 Antibody Rapid Card Test , Sars Cov-2 Antibody Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Anti – Hbsantibody Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Anti Hbc Igm Antibody Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Hbe Antigen Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Anti Hbe Antibody Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Ebv Igm Antibody Elisa Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Panfungal Dna Qualitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Fungal Qualitative Pcr For Mucormycosis • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Hiv Quantitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Ebv Quantitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Hsv Quantitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Hpv Quantitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Cmv Quantitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Cmv ( Dna ) Qualitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Hsv 1 / 2 ( Dna ) Qualitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Chlamydia Trachomatis Qualitative Pcr Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. • The Kit Should Be Compatible With Multiple Extraction And Pcr Systems Especially Cfx96™ Real-Time Pcr Detection System ( Bio-Rad ) , Cfx96™ Deep Well Real-Time Pcr Detection System ( Bio-Rad ) , Quantstudio™ 5 Real-Time Pcr ( Applied Biosystem ) Etc And Should Have Documented Proof For The Same. , Hbsag Rapid Test • Should Be Capable Of Detecting Preferably All 14 Mutants Of Hbsag. • Lateral Flow Through Technology. • Analyticalsensitivity Should Be Around 0.1 Iu / Ml. • Should Have With Positive Control. • Should Be Who Pre-Qualified And Nib Evaluated. • Should Be Preferably Ce Marked / Certified. • Note:- Sensitivity & Specificityshould Preferably Be >99% , Glass Slide ( 75 X 25Mm ) Thickness 1.45 Mm , Cover Slip 22 X 22 Mm Thickness 0.13 -0.16 , Cover Slip 22 X 60 Mm No.0 English Glass , Glass Petridishautoclavable 150Mm X 20Mm , Plasticpetridishautoclavable 100 Mm X 17Mm , Plasticpetridishdisposable Sterile100 Mm X 17Mm , Glass Petridishautoclavable 100Mm X 17Mm , Glass Tubes ( With Rim ) 6 X1 Inches 20Ml Capacity , Glass Tubes ( With Rim ) 5 X1 Inches 10Ml Capacity , Glass Tubes ( With Rim ) 4 X 0.5 Inches 5Ml Capacity , Yellow Tips ( 20-200 Ul ) , Blue Tips Upto 1000 Ul , Test Tube Stand Of Hard Plastic / Steel- • 96 Vials, 12Mm X 75 Mm / 100 Mm Test Tubes • 12 Places For 25 Mm Diameter Test Tubes • Stand For Centrifuse Tubes 1.5 Ml, 2.2 Ml & 2.7Ml Capacity • Stand For Vials 5 Ml Vial With 24 Vial Holding Capacity, Hole Size 14Mm • 2 Shelves Folding Stand, 18 Tubes Holding Capacity, Hole Size 18 Mm. • 3 Shelves Folding Stand, 18 Tubes Holding Capacity, Hole Size 16 Mm , Universal Sterile Container Screw Cap 30Ml Capacity ( Plastic ) , Micropipette Fixed 20Ul • The Lightest Manual Pipette • Fully Autoclavable At 121 °C • Rugged / Robust Construction & Durability • Universal Tip Compatibility With All Brands. • Soft Touch Tip Ejector. • Easy To Mentle – Dis-Mentle Pipette. , Micropipette Fixed 50Ul • The Lightest Manual Pipette • Fully Autoclavable At 121 °C • Rugged / Robust Construction & Durability • Universal Tip Compatibility With All Brands. • Soft Touch Tip Ejector. • Easy To Mentle – Dis-Mentle Pipette. , Micropipette Fixed 100Ul • The Lightest Manual Pipette • Fully Autoclavable At 121 °C • Rugged / Robust Construction & Durability • Universal Tip Compatibility With All Brands. • Soft Touch Tip Ejector. • Easy To Mentle – Dis-Mentle Pipette. , Micropipette Variable 5-50Ul • The Lightest Manual Pipette • Fully Autoclavable At 121 °C • Rugged / Robust Construction & Durability • Universal Tip Compatibility With All Brands. • Advance Volume Gearing ( Avg ) System To Avoid Sudden Change In Gearing. • 3-4 Digit Display In Pipetting • Soft Touch Tip Ejector. • Easy To Mentle – Dis-Mentle Pipette. • Large Ergonomics Display , Micropipette Variable 10-100Ul • The Lightest Manual Pipette • Fully Autoclavable At 121 °C • Rugged / Robust Construction & Durability • Universal Tip Compatibility With All Brands. • Advance Volume Gearing ( Avg ) System To Avoid Sudden Change In Gearing. • 3-4 Digit Display In Pipetting • Soft Touch Tip Ejector. • Easy To Mentle – Dis-Mentle Pipette. • Large Ergonomics Display , Micropipette Variable 100-1000Ul • The Lightest Manual Pipette • Fully Autoclavable At 121 °C • Rugged / Robust Construction & Durability • Universal Tip Compatibility With All Brands. • Advance Volume Gearing ( Avg ) System To Avoid Sudden Change In Gearing. • 3-4 Digit Display In Pipetting • Soft Touch Tip Ejector. • Easy To Mentle – Dis-Mentle Pipette. • Large Ergonomics Display , Antiseptic Hand Wash , Tissue Paper Rollpremium Extra Large With425 Sheets ( 2 Ply ) Size 95 X 110 Mm. , Drayers Tubes , Felix Tubes , Marker Fine Tipblack / Red / Blue , Glass Marking Pencilwhite / Black , Whatman Filter Paper Grade 1 , Postmartum Gloves ( 7.5 Inches ) , Glass Bottle With Aluminum Cap For L.J. Medium ( 80Mm X 20 Mm ) , Cryptococcal Antigen Lateral Flow Assay • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit. , Histoplasma Capsulatum Antigen Detection Test • Should Be Preferable Ce Marked / Certified. • Qc Certificate To Be Enclosed With Each Kit.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Mar-2024 CORRIGENDUM OF DATE Date 20-05-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 240000.0 /-
Tender Value
INR 1.20 Crore /-

Attachment

FileName File Description File Size
60875797-9e24-44bb-8bce-d4a241ffd80c.html Tender Notice 0 KB
BOQ_690651.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB
Tendernotice_2.pdf Tender Document 0 KB

BOQ Items

Name of Work: Supply of various type of test kits and consumables for Microbiology Department
Sl. No. Item Description
1Dengue Rapid test for detecting NS1 antigen & IgG & IgM antibody. • Should be capable of detecting dengue infection from day-1 & should be preferably capable of detecting all 04 serotypes of Dengue virus. • Should have High sensitivity and specificity and positive Control.
2RA(Latex Agglutination test)- • Should be preferably CE marked/certified. • Reagent should be calibrated against WHO international standard. • Latex particles coated with purified human gamma globulin. • Should have with positive Control
3CRP (Latex Agglutination test) • Should be preferably CE marked/certified. • Latex particles coated with anti-human CRP. • Should have with positive Control.
4ASO(Latex Agglutination test) • Should be preferably CE marked/certified. • Latex particles coated with purified streptolysin O.
5HBsAg Rapid test • Should be capable of detecting preferably all subtypes of HBsAg. • Lateral Flow through technology. • Antigen sensitivity should be around 0.5ng/ml. • Should have with Positive Control. • Note:- Sensitivity & Specificityshould preferably be >99%
6Anti HCV Rapid test- • Lateral Flow through technology. • Should be capable of detecting preferably all subtypes of HCV. • Note:- Sensitivity & Specificityshould preferably be >99%
7Rapid Malaria antigen card test • Based on pLDH for Pv & HRP-2 detection for Pf i.e. • Should be Pv & Pf specific. • Should preferably be developed according to WHO guidelines & Hence approved.
8Widal slide test • Stabilized reagent for long shelf life (18 months or more at 2 to 8 oC.) • Available in 5ml vials separately Salmonella O, Salmonella H, Salmonella A (H) & Salmonella B(H). • Should be preferably CE marked/certified.
9UPT Card test
10RPR Slide test • Should be preferably CE marked/certified. • Ready to use reagent. • Positive control provided with kit. • Stabilized reagent for long shelf life (18 months or more) • Specimen can be plasma/Serum can be used without heat inactivation. • Preferably calibrated to WHO reference serum for serodiagnostic test for treponemal infection.
11Brucella (Rose Bengal Test) • Should be preferable CE marked/ certified. • Positive control should preferably be supplied along with kit. • More than 12 months reagent shelf life at 2 to 8 degree c.
12Scrub Typhus Rapid card Test • Long Shelf Life (more than 18 months at 2-30 oC) • Lateral Flow through technology. • Sensitivity & Specificityshould preferably be >99%
13Dengue NS1 ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
14Dengue IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
15Dengue IgG ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
16Scrub typhus IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
17Scrub typhus IgG ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
18HAV IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
19HEV IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
20Brucella IgGELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
21Brucella IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
22Chikungunya Rapid card test. • Based in sandwich immunoassay principle. • High sensitive & Specific. • More than 12 months shelf life.
23Chikungunya IgM ELISA Test. • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
24HBsAgELISA Test. • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
25HCVELISA Test. • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
26HIV (Rapid tests of two different types based on different principles) • 4th generation test for differential detection of P24 antigen & HIV-I & II antibody. Flow through technology & Interpretation time around 5 to 10 minutes, approved & evaluated by NIV/NARI and WHO (NACO). • Test for detecting both antigen & antibody of HIV by examination of whole blood/ Plasma/Serum. Should be WHO/NACO approved. • Note:- Sensitivity & Specificity should preferably be >99%
27Syphilis Rapid Strip/ Card test
28LEPTOSPIROSIS IgG ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
29LEPTOSPIROSIS IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
30LEPTOSPIROSIS RAPID CARD TEST
31FUNGAL MARKER 1-3 BETA-D-GLUCAN ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
32FUNGAL MARKER GALACTOMANNAN ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
33ANTI ECHINOCOCCAL IgG ANTIBODY ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
34TOXOPLASMA IgG ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
35TOXOPLASMA IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
36RUBELLA IgG ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
37RUBELLA IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
38CMV IgG ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
39CMV IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
40HSV IgG ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
41HSV IgM ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
42Salmonella typhi Rapid Card Test for detecting both IgG & IgM antibody. • Long shelf life (18 months or more at 2 to 30 oC.) • Should have High sensitivity and specificity and positive Control.
43SARS CoV-2 Antibody Rapid Card Test
44SARS CoV-2 Antibody ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
45Anti – HBsAntibody ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
46Anti HBc IgM Antibody ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
47HBe Antigen ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
48Anti HBe Antibody ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
49EBV IgM Antibody ELISA Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
50Panfungal DNA Qualitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
51Fungal Qualitative PCR for Mucormycosis • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
52HIV Quantitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
53EBV Quantitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
54HSV Quantitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
55HPV Quantitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
56CMV Quantitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
57CMV (DNA) Qualitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
58HSV 1/2 (DNA) Qualitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
59Chlamydia Trachomatis Qualitative PCR Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit. • The kit should be compatible with multiple extraction and PCR systems especially CFX96™ Real-Time PCR Detection System (Bio-Rad), CFX96™ Deep Well Real-Time PCR Detection System (Bio-Rad), QuantStudio™ 5 Real-Time PCR (Applied Biosystem) etc and should have documented proof for the same.
60HBsAg Rapid test • Should be capable of detecting preferably all 14 mutants of HBsAg. • Lateral Flow through technology. • Analyticalsensitivity should be around 0.1 IU/ml. • Should have with Positive Control. • Should be WHO pre-qualified and NIB Evaluated. • Should be preferably CE marked/certified. • Note:- Sensitivity & Specificityshould preferably be >99%
61GLASS SLIDE (75 X 25mm) thickness 1.45 mm
62COVER SLIP 22 x 22 mm thickness 0.13 -0.16
63COVER SLIP 22 x 60 mm NO.0 English Glass
64GLASS PETRIDISHAutoclavable 150mm X 20mm
65PLASTICPETRIDISHAutoclavable 100 mm X 17mm
66PLASTICPETRIDISHdisposable sterile100 mm X 17mm
67GLASS PETRIDISHAutoclavable 100mm X 17mm
68GLASS TUBES( with rim) 6 x1 inches 20ml Capacity
69GLASS TUBES( with rim) 5 x1 inches 10ml Capacity
70GLASS TUBES( with rim) 4 x 0.5 inches 5ml Capacity
71YELLOW TIPS (20-200 ul)
72BLUE TIPS upto 1000 ul
73TEST TUBE STAND OF HARD PLASTIC/ STEEL- • 96 vials, 12mm x 75 mm / 100 mm test tubes • 12 places for 25 mm diameter test tubes • Stand for centrifuse tubes 1.5 ml, 2.2 ml & 2.7ml capacity • Stand for vials 5 ml vial with 24 vial holding capacity, hole size 14mm • 2 shelves folding stand, 18 tubes holding capacity, hole size 18 mm. • 3 shelves folding stand, 18 tubes holding capacity, hole size 16 mm
74UNIVERSAL STERILE CONTAINER SCREW CAP 30ml capacity (Plastic)
75MICROPIPETTE FIXED 20ul • The Lightest Manual Pipette • Fully Autoclavable at 121 °C • Rugged/Robust Construction & Durability • Universal Tip Compatibility with all brands. • Soft touch tip ejector. • Easy to mentle – dis-mentle pipette.
76MICROPIPETTE FIXED 50ul • The Lightest Manual Pipette • Fully Autoclavable at 121 °C • Rugged/Robust Construction & Durability • Universal Tip Compatibility with all brands. • Soft touch tip ejector. • Easy to mentle – dis-mentle pipette.
77MICROPIPETTE FIXED 100ul • The Lightest Manual Pipette • Fully Autoclavable at 121 °C • Rugged/Robust Construction & Durability • Universal Tip Compatibility with all brands. • Soft touch tip ejector. • Easy to mentle – dis-mentle pipette.
78MICROPIPETTE VARIABLE 5-50ul • The Lightest Manual Pipette • Fully Autoclavable at 121 °C • Rugged/Robust Construction & Durability • Universal Tip Compatibility with all brands. • Advance Volume Gearing (AVG) System to avoid sudden change in gearing. • 3-4 digit display in pipetting • Soft touch tip ejector. • Easy to mentle – dis-mentle pipette. • Large ergonomics display
79MICROPIPETTE VARIABLE 10-100ul • The Lightest Manual Pipette • Fully Autoclavable at 121 °C • Rugged/Robust Construction & Durability • Universal Tip Compatibility with all brands. • Advance Volume Gearing (AVG) System to avoid sudden change in gearing. • 3-4 digit display in pipetting • Soft touch tip ejector. • Easy to mentle – dis-mentle pipette. • Large ergonomics display
80MICROPIPETTE VARIABLE 100-1000ul • The Lightest Manual Pipette • Fully Autoclavable at 121 °C • Rugged/Robust Construction & Durability • Universal Tip Compatibility with all brands. • Advance Volume Gearing (AVG) System to avoid sudden change in gearing. • 3-4 digit display in pipetting • Soft touch tip ejector. • Easy to mentle – dis-mentle pipette. • Large ergonomics display
81ANTISEPTIC HAND WASH
82TISSUE PAPER ROLLPremium Extra Large with425 sheets (2 Ply ) size 95 x 110 mm.
83DRAYERS TUBES
84FELIX TUBES
85MARKER Fine TipBLACK/RED/BLUE
86GLASS MARKING PENCILWHITE/BLACK
87WHATMAN FILTER PAPER grade 1
88POSTMARTUM GLOVES (7.5 Inches)
89GLASS BOTTLE WITH ALUMINUM CAP FOR L.J. MEDIUM (80mm x 20 mm)
90Cryptococcal Antigen Lateral Flow Assay • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.
91Histoplasma Capsulatum Antigen Detection Test • Should be preferable CE marked/ certified. • QC certificate to be enclosed with each kit.