Tender For Annual Work Contract For Third Party Monitoring Work Of Air Water Noise Pollution And Collection Testing Of Used Oil Lubricating Oil Transformer Oil Fire Resistance Fluid Frf For 4X210 Mw 1X500 Mw At Sgtps Mppgcl Birsinghpur, birsinghpur-Madhya Pradesh

Madhya Pradesh Power Generating Company Limited-MPPGCL has published Tender For Annual Work Contract For Third Party Monitoring Work Of Air Water Noise Pollution And Collection Testing Of Used Oil Lubricating Oil Transformer Oil Fire Resistance Fluid Frf For 4X210 Mw 1X500 Mw At Sgtps Mppgcl Birsinghpur. Submission Date for this Tender is 29-04-2024. Lubricating Oils Tenders in birsinghpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42813520
Corrigendum : Tender For Annual Work Contract For Third Party Monitoring Work Of Air Water Noise Pollution And Collection Testing Of Used Oil Lubricating Oil Transformer Oil Fire Resistance Fluid Frf For 4X210 Mw 1X500 Mw At Sgtps Mppgcl Birsinghpur
Open Tender
Indian
Madhya Pradesh
birsinghpur
29-04-2024

Tender Details

tender for Annual Work Contract For Third Party Monitoring Work Of Air Water Noise Pollution And Collection Testing Of Used Oil Lubricating Oil Transformer Oil Fire Resistance Fluid Frf For 4X210 Mw 1X500 Mw At Sgtps Mppgcl Birsinghpur As Per Tender Schedule

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Mar-2024 1st Tender Extention Notice Date 03-04-2024
2 04-Apr-2024 2nd E-Tender Extension Notice Date 12-04-2024
3 13-Apr-2024 Third extension of due dates Date 22-04-2024
4 24-Apr-2024 4th due date extension Date 29-04-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 40040.0 /-
Tender Value
INR 20.02 Lakhs /-

BOQ Items

Name of Work:Annual work contract for “Third party monitoring work of Air, Water, Noise pollution and collection & testing of used oil (Lubricating Oil, Transformer oil & Fire resistance fluid (FRF)) for 4x210 MW & 1x500 MW”, at SGTPS MPPGCL Birsinghpur. As per tender schedule.
Sl. No. Item Description
1AIR POLLUTION
2Determination of Mercury in the Stack emission of 1x500 MW,SGTPS,MPPGCL,Birsinghpur.
3Determination of parameters of Ambient Air Quality at wind-ward direction (S.W.)(near CAAQMS-1) inside power house premises for following:-
4Lead (Pb) in µg/M3
5Ammonia (NH3)in µg/M3
6Benzene (C6H6)in µg/M3
7Benzo (a) Pyrene (BaP) (particulate phase only)in ng/M3
8Arsenic (As) in ng/M3
9Nickel (Ni)in ng/M3
10Mercury (Hg)in ng/M3
11Determination of parameters of Ambient Air Quality at Lee-ward direction (N.E.)(near CAAQMS-2 room) inside power house premises for following:-
12Perticulate matter (size less than 10 µm) or PM10 in µg /M3
13SO2 inµg/M3
14NO2 inµg/M3
15CO in mg/m3
16Perticulate matter (size less than 2.5 µm) or PM2.5 in µg /M3
17Ozone (O3) in µg/M3
18Lead µg/M3
19Ammonia (NH3)in µg/M3
20Benzene (C6H6)in µg/M3
21Benzo (a) Pyrene (Bap) (-particulate phase only)in ng/M3
22Arsenic (As) in ng/M3
23Nickel (Ni) in ng/M3
24Mercury (Hg) in ng/M3
25Determination of parameters of Ambient Air Quality in Colony/residantial area :-
26CO in Mg/M3
27Ozone (O3) in µg/M3
28Lead (Pb) in µg/M3
29Ammonia (NH3)in µg/M3
30Benzene (C6H6)in µg/M3
31Benzo (a) Pyrene (BaP) (particulate phase only) in ng/M3
32Arsenic (As) in ng/M3
33Nickel (Ni)in ng/M3
34Mercury (Hg)in ng/M3
35Determination of parameters of Ambient air quality in two directions :- 01. At wind-ward (SW) direction - (Changera village) 02. At Lee-ward (NE) direction -(Mundaria village) outside power house premises for following:-
36Perticulate matter (size less than 10 µm) or PM10 in µg /M3
37SO2 inµg/M3
38NO2 inµg/M3
39CO in mg/m3
40Perticulate matter (size less than 2.5 µm) or PM2.5 in µg /M3
41Ozone (O3) in µg/M3
42Lead µg/M3
43Ammonia (NH3)in µg/M3
44Benzene (C6H6)in µg/M3
45Benzo (a) Pyrene (Bap) (-particulate phase only)in ng/M3
46Arsenic (As) in ng/M3
47Nickel (Ni) in ng/M3
48Mercury (Hg) in ng/M3
49WATER POLLUTION
50Collection and Testing ofAsh Bund Effluent from Ash Dyke for following, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified :-
51Oil & Grease (mg/l)
52Colour (Hazen unit)
53Total dissolved solid (mg/l)
54COD (mg/l)
55Toxicity (Toxicity Factor-TF)
56Odour
57Arsenic (As) (mg/l)
58Mercury(Hg) (mg/l)
59Chromium (mg/l)
60Lead (mg/l)
61Collection & Analysis of following water samples as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified :--
62Reservoir Water Sample before confluence point of plant discharge (01 no. sample)
63Reservoir Water Sample at 100 mtr from confluence point of Once through condansor cooling system (01 no. sample)
64Ground Water Samples at distance of 10 km from power house in four directions (04 nos. Sample) Total 06 Nos. Samples for following:-
65pH/Temp.(0C)
66Total suspended solids (mg/l)
67Oil & Grease (mg/l)
68TDS (mg/l)
69BOD & COD (mg/l)
70Turbidity (NTU)
71Total Hardness (mg/l)
72Copper (mg/L)
73Iron (mg/l)
74Chromium (mg/l)
75Cyanide (mg/l)
76Fluoride (mg/l)
77Cadmium(mg/l)
78Lead (mg/l)
79Arsenic(mg/l)
80Mercury (mg/l)
81Titanium (mg/l)
82Zinc (mg/l)
83Dissolved Oxygen (mg/l)
84Carbonates (mg/l)
85Bicarbonates (mg/l)
86Sulphates (mg/l)
87Chlorides (mg/l)
88Alkalinity (mg/l)
89Sodium (mg/l)
90Potassium (mg/l)
91Collection & Analysis of treated Effluent of Effluent Treatment Plant (ETP), as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, for following :-
92Oil & Grease (mg/l)
93TDS (mg/l)
94BOD3 days 27oC & COD (mg/l)
95Dissolved Oxygen (mg/l)
96Chlorides (mg/l)
97Collection & Testing of 03 Nos. Peizometer well point Samples, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, for following :-
98pH/Temp. (0C)
99Total suspended solids (mg/l)
100Oil & Grease (mg/l)
101TDS (mg/l)
102BOD & COD (mg/l)
103Turbidity (mg/l)
104Total Hardness (mg/l)
105Copper (mg/l)
106Iron (mg/l)
107Chromium (mg/l)
108Cyanide (mg/l)
109Fluoride (mg/l)
110Cadmium (mg/l)
111Lead (mg/l)
112Arsenic (mg/l)
113Mercury (mg/l)
114Titanium (mg/l)
115Zinc (mg/l)
116Dissolved Oxygen (mg/l)
117Carbonates (mg/l)
118Bicarbonates (mg/l)
119Sulphates (mg/l)
120Chlorides (mg/l)
121Alkalinity (mg/l)
122Sodium (mg/l)
123Potassium (mg/l)
124Collection & Analysis ofD.M. Plant Effluent, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, for following :-
125Temp.(0C)
126Total suspended solids (mg/l)
127Oil & Grease (mg/l)
128TDS (mg/l)
129Alkalinity (mg/l)
130Copper (mg/l)
131Iron (mg/l)
132Collection & Analysis ofIndustrial Drain Samples - 05 Nos. Boiler Blow Down & 05 Nos. Condenser Cooling Discharge, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified, Total 10 nos. samples for following:-
133pH/Temp.(0C)
134Total suspended solids (mg/l)
135Oil & Grease (mg/l)
136TDS (mg/l)
137Alkalinity (mg/l)
138Copper (mg/l)
139Iron (mg/l)
140Collection & Testing ofDomestic Water Sample before & after treatment including bactereological testing for E. Coli & Total coliform bacteria, as per latest edition of the Indian Standards (IS) Specifications or as per latest edition of APHA, New York U.S.A. if IS method is not specified. Total 02 Nos. samples.
141NOISE POLLUTION
142Noise Pollution Monitoring Inside & Outside the Power House at following locations as below:-
143Near Turbine
144Near Boiler
145WT Plant
146PF Mill Area
147Crusher House
148Coal Handling Plant
149Ground floor near condenser
150Office area in power house
151Colony area
152Hospital area
153All four directions at 10 km redius around the power house
154Collection and analysis of used oil (Lubricating oil, Transformer oil & fire resistance fluid (FRF) oil, as per schedule -V of Hazardous & other waste (Management & Trans-boundary Movement) Rule-2016 for the following parameters:-
155Polychlorinated Biphenyl (PCBs)
156Lead (PPM)
157Arsenic (PPM)
158Cadmium+chromium+Nickel (PPM)
159Polyaromatic Hydrocarbons (PAH) %
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail