Tender For Construction Work Of Multipurpose Hall And Drinking Water Facility At Govt. High School Agwanpur District Meerut, meerut-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Tender For Construction Work Of Multipurpose Hall And Drinking Water Facility At Govt. High School Agwanpur District Meerut. Submission Date for this Tender is 14-03-2024. Building Work Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42798737
Corrigendum : Tender For Construction Work Of Multipurpose Hall And Drinking Water Facility At Govt. High School Agwanpur District Meerut
Open Tender
Indian
Uttar Pradesh
meerut
14-03-2024

Tender Details

Construction Work Of Multipurpose Hall And Drinking Water Facility At Govt. High School Agwanpur District Meerut

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Mar-2024 Extend of Date Date 13-03-2024
2 13-Mar-2024 Date of Extend Date 14-03-2024

Key Value

Document Fees
INR 11800 /-
EMD
INR 94000.0 /-
Tender Value
INR 46.70 Lakhs /-

BOQ Items

Name of Work:Construction work of Multipurpose Hall and Drinking Water Facility at Govt. High School Agwanpur District Meerut
Sl. No. Item Description
1MULTIPURPOSE HALL Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches.
2Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.
3Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
4Providing and injecting chemical emulsion for preconstructional antitermite treatment
5P/laying of R.C.C. with cement, sand & stone grit 10&20 mm, M-20 grade in Footing including necessary centering and shuttering, supply of all materials, labour, tools & plants etc required for proper completion of work.
6P/laying of R.C.C. with cement, sand & stone grit 10&20 mm, M-20 grade in Plinth /Slab Beam including necessary centering and shuttering, supply of all materials, labour, tools & plants etc required for proper completion of work.
7P/laying of R.C.C. with cement, sand & stone grit 10&20 mm, M-20 grade in Column including necessary centering and shuttering, supply of all materials, labour, tools & plants etc required for proper completion of work.
8P/laying of R.C.C. with cement, sand & stone grit 10&20 mm, M-20 grade in Lintel Beam including necessary centering and shuttering, supply of all materials, labour, tools & plants etc required for proper completion of work.
9P/laying of R.C.C. with cement, sand & stone grit 10&20 mm, M-20 grade in Slab including necessary centering and shuttering, supply of all materials, labour, tools & plants etc required for proper completion of work.
10Ist Class brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
11Painting on D.P.C with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 Kg/Sq. M. approx including cost of fuel if any.
12Ist Class Brick work in super-structure above plinth level up to floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:4 cement & coarse sand)
13Ist Class Brick work in super-structure above plinth in1:4 cement and coarse sand mortar in superstructure for wall thickness 11.5 cms & below brick work.
14Providing & laying "brick Coba" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound .
15P/F Mild steel TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.
16Providing and fixing of Powder coated Aluminium Section Door using section 83.5x44.45 mm and 104x44.45 mm including all material, labour, T&P complete.
17Providing and fixing of Powder coated Aluminium Section 82.5x38.00 mm and 47.62x44.45 mm Windows as per Drawing including all material, labour, T&P complete.
18Providing and fixing M.S. Tubular frames for Grill with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1915 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand)
2012mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand.
2112 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
2225 mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20 mm nominal size laid in one layer neat cement.
23Providing and laying Virtified Tiles in flooring & Skirting complete in all respect
24Supply and fixing of Kota stone in flooring 25 mm thick and joint filled with 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12 mm basecoat (bedding) of 1:2 cement & coarse sand mortar and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all material, labour, tools & plants etc. required for proper completion of the work.
25Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
26Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
27Providing & fixing glass strips of 4.00 mm thickness 2.2 cm depth in joints of floors & skirtings at the time of laying floors, flash with floor level, including labour and T&P etc. complete.
28Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.
29Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
30Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling)
31Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
32Supply and Fixing Galvanized corrugated iron roofing 24 B.W.G. in position including supply of all materials, labour, tools & plants etc. required for proper completion of the work and including wastage.
33Steek work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washer etc. complete (Hot finishes welded type tubes.)
34Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
35Gutter (600 mm over all girth)
36Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware /Seabird/ Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
37Providing and fixing whiteviterous china pedestal type water closet (europen type) withseat andlid, 10 litre low level flusing cistemwith fittings &C.I/M.S Brakets ,40mm fluse bend ,overflow arrangmentwith special of standard make and mosqiito proof coupling of approvedmuncipal designcomplete including painting of fitting and brackets , cutting and making good the wallsand floorswhere everrequired .Confirming to IS : 7231, Parryware, /Hindware/ Seabird/Orient(Coral) W.C. pan with ISI markedwhite solidplastic seat
38Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
39Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : one urinal basins withwhite P.V.C. automatic flushing cistern
40Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32/40 mm dia
41Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
42Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length, 15 mm nominal bore
43Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931,a) 15 mm nominal bore
44Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.a) 15 mm nominal bore
45Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931,a) 15 mm nominal bore
46P/Placing on terrace (at all floor levels) PVC water storage tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and base supports for tank complete as per direction of Engineer-in-charge.
47Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes
48Same as above but 25mm dia nominal outer dia pipes
49Providing and fixingCPVCpipes complete with CPVC fittingsand clamps, including cuttingand making good walls etc. (internal work). 20mm dianominal bore
50Same as abovt but 25mm dia nominal bore
51Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore
52Providing and fixing on wall face unplasticised-Rigid PVCpipes. 100 mm dia P.V.C. pipe
53Same as abovt but75mm dia P.V.C. pipe
54Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm
55Same as abovt but 10x110x110 mm
56Single tee without door 75x75x75 mm
57Same as abvoe but 10x110x110 mm
58Bend 87.5° 75 mm diameter
59Same as above butv 110 mm diameter
60Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm
61Same as abovt but 110 mm
62Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
63Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil, Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm.
64Providing, laying and jointing PVC pipes including testing of joints etc. complete. 100mm diameter
65Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia SW pipe
66Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design, 150 x 100 mm size P type
67Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
68Extra for depth for manholes: Size 90x80cm with FPS bricks(class I) M-150
69Construction of Septic Tank of Size 2x1x1.20 M complete with all material, labour , T&P required as per Drawing & design
70Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mmdiameter, 1.8 m long complete as standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
71Wiring points for light with 1.50 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.
72Same as item above but for fanandlight duty exhaust fan.
73Same as item above but for5 Amp plug point
74Supply and wiring of submain 2 number 2.5 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
75Supply and wiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
76Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work .( for Telephone/Televisionpoints)
77Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
78Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
79S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.
80Supplyfixingofelectronic fan regulator(modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
81Supplyanf fixing of recess / Surface /Pendent mounting round 24 to 32 Watt LED Down Lighter having Powder Coated die cast aluminiumhousing with heat sink diffuser / Reflector and driver set complete in all respect.CAT -AA
82Supply and fixing of single light wall bracket on matching M.D.F.E.G. Board base etc. complete in all respects. Category AA
83S/F of LED tube light with batten suitable for up to 1X22 watt LED tube light fitting including tube on suraface complete in all respect.CAT-AAA a) 1x22 Watt.
84Supply & fixing of Call Bell Of Approved Make on matching polished MDFEG/TEAK PLY board including making connectionetc. as required.
85Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work. 600x480x200 mm. size
86Supply and fixing of flush/surface mounting distribution boardswithout MCB with additional metal doorcomplete in all respects.(CAT: B) 6 Way TPN
87Supply and fixing of 240 volts "L" series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. (CAT: B)6 - 32 amps.
88Supply fixing of 40 Amp. 4 pole mcb(10KA). (CAT: B)
89Supply and fixing of power plug with 20 A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket.
90Supply and fixing Single Pole MCBS Blanking Plate complete in all respects.
91Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
92Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
93Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.
94Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep
95Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300 mm sweep.
96Supply andlayingofaluminiumconductor PVC. insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.Make- Havels / Pasaka 16 sqmm4core
97Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete with all respects. The instrument chamber shall be separate and shall comprise of plug type ammetre, voltmetre, selector switches for ammetre and voltmetre instrument, fuses current transformer etc. the board shall have suitable capacity electrolytic Aluminium busbars as per IS : 8623 insulated with heat shrink sleevings and mounted on non hygroscopic supports such as CMC/DMC supports with detachable side cover and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entry boxes in case of pedestal type, cable sockets compression glands and indicating lamp for incoming etc. The job include the grounting of the board as per direction of Engineer in charge. All outgoing switches of 100 Amp and above will be provided with Amp Metre, current transformers and selector switches etc. and instrument fuses. The switch board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm /2mm cubicle type switch board shall be of cat. A. B. & B -II and pdestal type for cat. C only a) Incoming: 100 Amp. TPN -1 No.,Outgoing:32 Amp. TPN -3 Nos.
98Supply and fixing of fire extinguiser ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work
99Supply and fixing of fire extinguiser ,CO2 Type 4.5 kg capacity (ISI Marked IS : 2878 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work.
100Providing and laying GSB Layer under CC interlocking tiles for base complete
101Supply & Laying of Inter locking Tiles - Rubber moulded reflactive Zig- Zag 80 mm(M-30)inter locking concret block pavements
102DRINKING WATER FACILITY Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
103Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors.
104Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
105Providing and injecting chemical emulsion for preconstructional antitermite treatment
106Reinforced cement concrete work for Slab. (Using 1:1.5:3 Mix concrete)
107As in item above for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)
108Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, including cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) UPTO P.L
109Providing and laying in position specified grade of reinforced cement concrete, including the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) in foundation
110First class brick work in 1:4 cement and coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc reqiored for proper completion of the work.
111Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
112Same as in item abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms.
113Same as in item abovebut in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
114Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
115P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for completion ofwork and including supply of steel its wastage bend hooks & authorised over lapping shall be measured upto floor two level.
11615 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
11712mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand
11815 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
119Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
120Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
121Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
122Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth.
123Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth including cost of material, labour, T & P etc. complete.
124Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 150mm dia
125Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (I) 150 mm nominal size dia
126Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (I) 150 mm nominal size dia.
127Supplying, filling, spreading & leveling p gravel of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
128Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
129Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :150 mm dia
130Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp.
131Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia.
132PUMPING SET KSB, V-GUARD, CROMPTON make submersible pump set suitable for installation in bore well of min 150 mm inner dia preferably more and having under noted With Electrical control panel, supporting wire, clips etc specifications.[2.0 H.P.}
133Supply and fixing of finolex of copper cable ISI marked submersible cable of size 3 core 2.5 sq mm
134Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore
135Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
136Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter
137Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
138Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm
139Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
140Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.internal work -Exposed on wall20mm dia nominal outer dia pipes
14125mm dia nominal outer dia pipes
142Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes
14325mm dia nominal outer dia pipes
144Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore
145Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore
146Providing and fixing of usha water cooler 150 ltr/hours (usha SRA 150150 G S S 304)
147Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 893115mm nominal bore
148Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore
149Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
150Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR Civil-21
151Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885
152Wiring points for light with 1.5 sqmm.FRLSH PVC insulated single core Copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.
153Same as item above but for5amp plug point with piano type switch and socket etc.
154Addition for light / fan points with modular type switchin place of piono type switch.
155Addition for plugpointswith modular type switchin place of piono type switch.
156Supply & wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.
157Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
158Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
159Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( forTelephone)
160Supply & fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)
161S&F surface/flush mounting 4 ways SPN distribution board without MCB complete in all respect,as directed at site by Engineer in charge. 4 Way SPN
162Supply and fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A)
163Supply fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A) 40 Amp. FP MCB
164Supply and fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
165Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. (CAT: A)