Tender For Additional/Alternator To Sewage Line At Certain Units And Spl Repair To Bldg No P-716 Under Age B/R- V And Age E/M -V Of Ge (N) Bathinda At Bathinda Mil Stn, bathinda-Punjab

Military Engineer Services-MES has published Tender For Additional/Alternator To Sewage Line At Certain Units And Spl Repair To Bldg No P-716 Under Age B/R- V And Age E/M -V Of Ge (N) Bathinda At Bathinda Mil Stn. Submission Date for this Tender is 28-05-2024. Building Work Tenders in bathinda Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42771388
Corrigendum : Tender For Additional/Alternator To Sewage Line At Certain Units And Spl Repair To Bldg No P-716 Under Age B/R- V And Age E/M -V Of Ge (N) Bathinda At Bathinda Mil Stn
Open Tender
Indian
Punjab
bathinda
28-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For additional/alternator To Sewage Line At Certain Units And Spl Repair To Bldg No P-716 Under Age B/R- V And Age E/M -V Of Ge (N) Bathinda At Bathinda Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Mar-2024 Corrigendum No 1 Date 11-04-2024
2 05-Apr-2024 Corrigendum No 2 Date 25-04-2024
3 25-Apr-2024 Corrigendum No 3 Date 06-05-2024
4 04-May-2024 Corrigendum No 4 Date 28-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 99400.0 /-
Tender Value
INR 49.70 Lakhs /-

Attachment

FileName File Description File Size
724d627d-7d55-4110-b6bc-b61a9df3575a.html Tender Notice 0 KB
BOQ_722716.xls Tender Document 0 KB
tender81.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:ADDN/ALTERATION TO SEWAGE LINE AT CERTAIN UNITS AND SPL REPAIR TO BLDG NO P-716 UNDER AGE B/R- V AND AGE E/M -V OF GE (N) BATHINDA AT BATHINDA MIL STN
Sl. No. Item Description
1SCHEDULE "A" B/R Works
2Excavation in trenches in soft / loose soil not exceeding 1.5 meter wide & not exceeding 1.5 meter in depth for foundations of manholes, sewerage pipe lines etc including getting out complete all as specified and as directed byEngineer-in-Charge .
3Description all as per serial item No 1.00 here-in-before but exceeding 1.5 meter and not exceeding 3.00 meter in depth. complete all as specified and as directed byEngineer-in-Charge .
4Demolition and breaking up drain pipes SGSW,AC or reinforced concrete pipe up to and incl 150 mm bore pipes all as specified and directed by Engineer-in-Charge.
5Demolition and breaking up drain pipes SGSW,AC or reinforced concrete pipe up to and incl 300 mm bore pipes all as specified and directed by Engineer-in-Charge.
6Material & labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate to drain pipe incl packing under & hunching against the sides of pipe 150 mm dia ( internal) after they are laid and tested in trenches complete all as specified..
7Material & labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate to drain pipe incl packing under & hunching against the sides of pipe 300 mm dia ( internal) after they are laid and tested in trenches complete all as specified..
8M&L 150mm Reinforced concrete pipes, class NP2, laid and jointed complete with collarscomplete all as specified and as directed by as Engr-in-charge
9M&L 300mm Reinforced concrete pipes, class NP2, laid and jointed complete with collarscomplete all as specified and as directed by as Engr-in-charge
10Demolition of brick work built in cement mortar including all quoins, pillars etc., but excluding pre-castcement concrete articles complete all as specified and as directed byEngineer-in-Charge .
11Material & labour for cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate for foundations, fillings & mass concrete complete all as specified and as directed byEngineer-in-charge.
12M&L Brick work with sub class ‘B’bricks old size straight or curved on plan exceeding 6 meter mean radius built in CM 1:4 complete all as specified and as directed byEngineer-in-Charge .
13Material & labour for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for manhole benching and coping , around interlocking paver blockcomplete all as specified and as directed byEngineer-in-charge.
14Material & labour for 15 mm thick cement plaster in CM 1: 4 on fair/ unfair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed byEngineer-in-charge.
15S&F in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation (size of cover 0.70 x 0.70 or as directed by EIC) conferming to IS 12592, fixed in cement cocrete 1:2:4. complete all as specified.
16Returning/filling in including spreading, leveling , watering & well ramming in layers not exceeding 25 cm thick each all as specified and as directed byEngineer-in-Charge.
17Removal of excavated material to distance not exceeding 1.5 meter above the starting point complete all as specified and as directed byEngineer-in-Charge .
18Supply only integral water proofing powder ISI make complete all as specified and directed by Engineer-in-Charge.
19Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
20Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
21Material and Labour for Roughening surfaces of existing concrete surfaces of roofby picking , sweeping , clean and washing down with water to remove dust etc and brushing with neat cement slurry @ 3.0 Kg of cement per Sqm complete all as specified and directed by Engineer-in-charge. Note: The rate of neat cement slurry @ 3.0 Kg of cement per Sqm is included in this item and nothing shall be paid extra on this account.
22Material and laboufor cement concrete (1:2:4) type B-0, using 12.50 mm graded stone aggregates as in roof padding including mixing with Water Proof Compound as per manufacturer"s instructions and finished even and fair complete all as specified and as directed by Engineeer-in-charge. Note :- Water Proof Compoundshall be measured and paid for separately under respective item of Schedule"A" BoQ..
23Material and Labour for 15 mm thick screed bed or bedding layer in cement mortar (1:4) on roof surfaces,parapet or vertical beam surface (horizontal or vertical) finishing the surfaces even and fair complete all as specified and as directed by Engineer-in- charge.
24Material and labour for tack coatlayer of blown grade bitumen of any penetration applied hot @ 1.70 Kg per Sqm andpriming the surface @ 1.70 Kg per Sqm and with and including material and labour for laying 3mm thick APP based polymer membrane of weighing not less than 3.5 Kg per Sqm reinforced with polyster non woven fabric (weight not less than 150 Gm per Sqm) laid on primed surface at by torch application with side overlap 75mm and end overlap 100mm and tucked into the chasesas a treatment for moderate condition complete all as specified and as directed by the Engineer-in-Charge. Note: The rate of3mm thick APP based polymer membrane is included in this item and nothing shall be paid extra on this account.
25Material and labour for cement concrete (1:2:4) type B-0, using 12.50 mm graded stone aggregates as in bands, bedding, benching of manholes, coping, surface channel, roof kerbs or mud stops, rounded or chamfered on edges etc including necessary form workcomplete all as specified and as directed by Engineer-in-charge.
26Taking down cement plaster of any description on brick or concrete surfaces, etc. including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in- charge.
27M & L 10 mm thick rendering in cement mortar 1:3 on ceiling finished the surface even and smooth without using extra cement and applying one coat of white wash including preparation of new plastered surfaces.
28M&L15 mm thick cement plaster on fair faces of bricks or concrete wallsin CM 1:6 finished even and smooth with out using extra cement on brick work or concrete surfaces including taking down cement lime plaster including applying two coats ofAcrylic distemper using painting roller including 2 to 3mm thck wall care putty complete all as specified.
29M & L 15 mm thick rendering in cement mortar 1:4 with water proofing compound as per manufacturer"s instructions( externally )and finishing the surface even and smooth without using extra cement andprimingplastered and other surfaces with alkali-resistant priming paint and applying two coat ofexterior emulsion paint (Apex) including preparation of new plastered surfaces on wall. complete all as specified and directed
30Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and as directed by Engineer-in- charge.
31Material and labour for Non Skid ceramic coloured tiles7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry@ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile includingnecessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
32Material and labour for Glazed ceramic coloured tiles of size 300mmx 200mm / 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry@ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thickrenderingin cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
33Material and labour for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.and Brushing neat cement slurry with 3.0kg of cement per square metre complete all as specified and as directed by Engineer-in-Charge.
34M&L 25 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) leveling course as in floor complete all as specified and directed
35Material and Labour for 20-25 mmthick Kota stone slab as approved by GEflooring, mirror polished laid over 15 mm thick screed bed in CM 1:4 laid and jointed with grey cement slurry @ 3 Kg/ Sqm mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed by Engineer-in- charge.
36Material and Labour for machine cut kota stone slab as approved by GE as in vertical surfaces, 20-25 mm thick laid overand including 10 mm thick rendering inCM 1:4 laid and jointed with grey cement slurry @ 3 Kg/ Sqm mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed by Engineer-in- charge.
37Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
38Material and labour for 75mm thickcement concrete ( 1:4:8),type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge.
39Material and Labour for machine pressed precast interlocking paver block 60 mm thick with grey cement and no pigment, factory made, any shape and size, conforming to IS 15658-2006, made out of M-35 grade concrete laid over and including 25 mm thick layer of sand cushioningcomplete all as specified and as directed by Engineer-in- charge. Note: The rate of 25mm thick layer of sand cushioning is included in this item and nothing shall be paid extra on this account. .
40Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden /PVC door s/steel ventilator) areanot exceeding 1.50 sqm each complete all as specified and asdirected by Engineer-in- charge.
41Taking down chowkhats or frames with shutters (without taking off shutters from the frames) areaexceeding 1.50 sqm but not exceeding 4 Sqm eachcomplete all as specified and asdirected by Engineer-in- charge. .
42Supply and fixingSolid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, fixed in opening using MS screw 75mm long with PVC fastener including making good disturbed wall surfaces (brick, plastering, tiles and painting work as per existing) complete all as specified and as directed by Engineer-in-Charge.
43Supply and fixing Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and as directed by Engineer-in-Charge.
44Supply and fixingfactory made 105mm x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including one shop coat of zinc chromate primer paint including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos. as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : -(i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
45Material and Labour for PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate as in back filling of pressed steel chowkhats single or double rebated or for fixing hold fasts etc complete all as specified and as directed by Engineer-in-charge.
46Supply and Fixing 35mm thick, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), using 2nd class hard wood (Bonsum/ Hollock) edges of frming plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc , sizes of members of shutters as specified in SSR Part-I, Section8, Clause 8.24 (a), supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-Charge.Note:- Wire gauze/ glass to be measured and paid separately.
47Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard woodwith lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhatcomplete all as specified and as directed by Engineer-in- charge.
48S&F for steel window box type double shutter( glazed with wire gauge)with side hung shutters includinghinges with steel handle and steel peg stay complete with glazing bar dovetailed or welded and including window guard bar, tower bolt,flat iron for fixing wire nettingincluding one shop coat of zink chromate primer paintand making good to distrubed portion match with existing surfaces completeall as specified.
49S&F factory made steel ventilators with top hung shutter incl hinges steel pegs & stays complete with one shop coat of red oxide primer including taking down old rusted ventilator and make good distrubed surface completeall as specified
50Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micorn) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., minimum thickness of powder coating 50 microndrawing and size as approved by GE complete all as specified and directed by Engineer-in-charge .
51Supply and Fixing factory made anodised aluminium door shutters, aluminium sections weighing not less than 0.55 kg/metre including necessary joining cleats, glazing clips, rubber neoprene packing, handle 2 Nos in each door, hinges, anodised aluminium snap beading, screws etcdrawing and size as approved by GE complete all as specified and as directed by Engineer-in- charge.
52Supply and Fixing sheet glass, 4.8 mm thick ordinary qualityin square not exceeding 0.50 Sqm in each pane fixed withaluminium and rubberbeads including Provn of glazing pins/spring clips wherever necessary complete all as specified and directedby Engineer-in- charge. .
53Supply and Fixing Stainless steelwire cloth, 0.56 mm nominal dia of wire & average width of aperture 1.18mm and fixed with tinned tacked or galvanized steel wire staples complete all as specified and as directed by Engineer-in- charge.
54Supply and Fixing 300mm long, aluminium anodised sliding door bolt with hasp, staple (bolt type), and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed by Engineer-in- charge.
55Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
56Supply only 100 mm long Butt hinges, heavy weight, cold rolled mild steel, and fixedcomplete all as specified and as directed by Engineer-in- charge.
57Supply & fixing 125mm long, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in- charge.
58Supply and Fixing 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in- charge.
59Supply and Fixing 150 mm long aluminium anodized barrel tower bolts, extruded section complete all as specified and as directed by Engineer-in- charge.
60Material and labour for preparation ofnew steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer primer complete all as specified & directed by Engineer-in- charge.
61M&L one coats of synthetic enameled paint overold steel surfaces of any description, over 10 cm in width or girth, not otherwise described including preparation of surfaces
62Material and labour for preparation ofnew wooden or wood based surfacesof any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
63Material and labour for preparation ofoldwooden or wood based surfacesof any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified & directed by Engineer-in- charge.
64Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittingslike elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe including taking down old existing galvanised steel water tubing omplete all as specified and as directed by Engineer-in- charge.
65Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittingslike elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipeincluding taking down old existing galvanised steel water tubing complete all as specified and as directed by Engineer-in- charge.
66Supply & fixing rotational mouldedpolyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing 20mm ball valve and gate valve including dismantling /taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge.
67Supply and fixing in replacement stainless steel chromium plated pipe 25mm dia, wall thickness of pipe not less than 20 guage, as curtain rod fixing with and including fancy type brackets and decorated end knobs (finials), stop roller etc, fixed on wall for doors and windows curtains, cuttings as required length and fixing at site including fixing arrangements, rawl plug, screws etc. including taking out old any type rod or pelmet boxes with curtain rod completeall as specified & directed by Engineer-in- charge.
68Supply and Fixing in repairs vitreous china wash down water closet pan (EWC) (pedestal pattern) white and trap including connection to drain (or outgoing pipe) and to flushing pipe of polyethylene of low or high density, antisyphonage pipe including white coloured closed pattern plastic seat cover and fixing bolt and flush pipe of polyethlene of low or high density 32mm dia (excluding flushing cistern ) anti syphonage pipe etc and connection to drain for outgoing pipe and to flushing pipe anti-syphonage pipe etc complete all as specified and as directed by Engineer-in- charge.
69Supply and Fixing in repairs vitreous china wash basin, white, with pedestal, size 550mm x 400mm excluding taps, waste, chain and plug and porcelain stopper including brackets (flat back or angle backe type) any size, including cutting for and pinning in ends of brackets or errecting stand, 32 mm dia waste pipe coupling & PVC waste pipe of 32mm dia etccomplete all as specifiedand as directed by Engineer-in- charge.
70Supply and Fixing in repairs PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets including 32 mm dia flush pipe of polyethylene of low or high density of PVCcomplete all as specifiedand as directed by Engineer-in- charge.
71Supply and Fixing in repairs vitreous china whiteHalf stall urinal,of size 420mm x 395mm x 635mm (minimum), exclusive flushing cistern, flushing pipe, but including white waste pipe, grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 , securing urinal to plugs with and including 60mm long brass screws or brackets, pointing around urinal backe in cement etc complete all as specifiedand as directed by Engineer-in- charge.
72Supply and fixing in replacement 600mm x 450mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame / beading alround made of aluminium channel, complete all as specified and directed by Engineer-in-Charge.
73Supply & fixing in repair 600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
74Supply and fixing Brass Chromium plated long body Bib Tap , screwed down, screwed for iron pipe or for brass ferrule for 15mm boreof pipe complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relivent IS.
75SSupply and fixing in replacement stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
76Supply and fixed in repair pillar tap cast copper alloy with capstan head, chromium plated,fancy type, high pressure with or without letter"Hot" or "Cold" with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :-The minimum weight of tap shall be as given in SSR or in relevant IS
77Supply and Fixing in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long betweenflanges complete all as specified and as directed by Engineer-in- charge.
78Supply and fixed in replacement aluminium( extruded section body) Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed
79Taking downAC eaves gutters and rain water pipe (any size or pattern ), including all fittings, heads, shoes, bends, swan necks, etc, complete all as specified and as directed by Engineer-in- charge.
80Supply and Fixing PVC SWR Pipe (ISI Marked) 110mm bore dia, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed by Engineer-in- charge
81Supply and Fixing PVC SWR Bend(ISI Marked) 110mm bore dia complete all as specified and as directed by Engineer-in- charge.
82Supply and Fixing PVC SWR Pipe (ISI Marked) 75mm bore dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
83Supply and Fixing PVC SWR Pipe Bend(ISI Marked) 75mm bore dia complete all as specified and as directed by Engineer-in- charge.
84Supply and fixing 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cementcomplete all as specified and as directed by Engineer-in-charge
85Supply and fixing Red colour Pre- painted galvatumesheet of CRIMP Profile (Curved Section) aluminium zinc coating GI based corrugatedsteel sheet 0.45mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws includig taking down existing sheet of any type and pattern complete all as specified and as directed by Engineer-in-charge.
86Material and Labour for mild steel work in tubular trusses, tubular/rectangular MS pipe such as vertical post, trusses, rafter, purlins etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed by Engineer-in-charge.
87EM SCHUDLE "A"
88Taking down old unsv copper/aluminium point wiring concealed / batten (light,fan, socket or power) complete, including fixture and fittings suchasswitches,sockets,ceiling roses,bell push,bell electric,lamp holder,bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron,round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
89Taking down old and unserviceable, distribution boardany type including , MCBs etc after removing all connection and make good the disturbed surface all as directed by Engr-in-charge.
90M&L in replacementfor Sub main wiring with proper colour coding , insulated , unsheathed , multistranded ,copper conductor FRLS, cable of 2 run 6 Sqrmm for phase and neutral and one run of 6.0 Sqrmm for earth wire unsheathed , miltistranded , copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length. Note : Wiring shall be done in proper colour coding.
91M&L for point wiring for one light/fan point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductormultistrand FRLS,PVC insulated (unsheathed) drawn into an including new concealed PVC rigid conduit 1.8mm wall thicknessISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
92All as per item No 90.00 above but for multi 5 pin 5 amp socket outlet on same board
93All as per item No 90.00 above but for multi 5 pin 5 amp socket outlet on Independent board
94All as per item No 90.00 above but for multi 6 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 sqmm copper conductor multistrand cable pvc insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia and unsteathed copper conductor multistrand cable 1.5 sqmm as earth wire FRLS pvc insulated in green color all as directed by engr-in-charge.complete with new CI/pressed steel sunken black with hylum top sheet cover 3mm thick
95S & F in replacement Socket outlet 5 Pin, 5A, flush type complete all as directed
96S&F in replacement forswitch piano, flush type single pole one way 5Amp, 240 volts all as specified .
97M&L switch piano flush button single pole one way 15 Amp all as specified
98M&L socket outlet 6 pin 15 Amp 240 volt multi purpose flush typeall as specified
99S&F ceiling rose, 3Phase/PVC/polycarbonate isolated body
100M&L for replacement distribution boardsheet steel phosphatised powder coatedfor MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as directed by Engr-in-Charge.
101S&F in repair MCB single pole and Neutral 32/40 Amp suitable for 240 volt.
102S&F in repair MCB single pole 5-32 Amp suitable for 240 volt.
103S&F in replacementnew generation energy saving ,wall mounted LED Tube lightbatten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED power factor > 0.95, 100 lumen/watt duly fitted on pvc square block 5700K (4" ft long ) with LED rod 20 watt, 230 Volts 50 Hz.
104Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete power factor > 0.95, 100 lumen/watt, CCT min 5700K
105M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
106Supply and fixing in replacement of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and old rusted and outdated ceiling fans deposited to MES store
107Making holes for 300 mm dia exhaust fan of suitable shape & size into or through brick walls at groung/First/Scond floor including plastering for making good to the original surfaces of any description disturbed including painting /distemper matching with the existing colour. Note : Rates are deems to be including charges of any type of T&P, Insurance of staff deployed at site.
108Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louverscomplete with louver shutter including fixing rawl plug/nut & bolts.
109S&L and testing cable XLPE Insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 25 Sqmm, 3.5 core in and incl taking out old one all as specified and directed.
110S&L GI tubing light graded 40 mm incl all accessories for encasing cables for mechanical protection, laid under plinth/floors/path culverts with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed of sizes (MS work will be measured under separate item in schedule)