Tender For Certain Special Repair To Pipe Lines, Fire Hydrant System, Voltage Stabilizer And Additional/Alternator To P-105 And Block 24 To 27 Of Tejas At Afssr Area Under Ge Af Gurgaon, gurgaon-Haryana

Military Engineer Services-MES has published Tender For Certain Special Repair To Pipe Lines, Fire Hydrant System, Voltage Stabilizer And Additional/Alternator To P-105 And Block 24 To 27 Of Tejas At Afssr Area Under Ge Af Gurgaon. Submission Date for this Tender is 04-04-2024. Fire Suppression System Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42771364
Corrigendum : Tender For Certain Special Repair To Pipe Lines, Fire Hydrant System, Voltage Stabilizer And Additional/Alternator To P-105 And Block 24 To 27 Of Tejas At Afssr Area Under Ge Af Gurgaon
Open Tender
Indian
Haryana
gurgaon
04-04-2024

Tender Details

Certain Special Repair To Pipe Lines, Fire Hydrant System, Voltage Stabilizer And Additional / Alternator To P-105 And Block 24 To 27 Of Tejas At Afssr Area Under Ge Af Gurgaon

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Mar-2024 Revised BOQ BOQ 28-03-2024
2 28-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work : CERTAIN SPECIAL REPAIR TO PIPE LINES, FIRE HYDRANT SYSTEM, VOLTAGE STABILIZER AND ADDN/ALTN TO P-105 AND BLOCK 24 TO 27 OF TEJAS AT AFSSR AREA UNDER GE AF GURGAON
Sl. No. Item Description
1Taking down 110 mm bore PVC (SWR) pipesof any description with fitting and making good to disterbed surfaces complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
2Taking down 75mm bore PVC (SWR) pipesof any description with fitting and making good to disterbed surfaces complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
3S&F 110mm bore PVC(SWR) pipes single socketed in any lengthpressure rating @6Kg/Sq cmmedium Grade fixed to walls using MS clamp at every 2mtr length including)includingall fittings complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
4S&F 110mm bore PVC(SWR) pipes single socketed in any lengthpressure rating @6Kg/Sq cmmedium Grade laid in floors includingall fittings complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
5S&F 75mm bore PVC(SWR) pipes single socketed Pressure rating @6Kg/Sq cm medium grade in any length with rubber ring joint, fixed to walls (using MS clamp at every 2mtr) length including taking down eaves, gutters rain water pipes (any size or pattern) including all fittings complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
6S&F 75mm bore PVC(SWR) pipes single socketed in any lengthpressure rating @6Kg/Sq cmmedium Grade laid in floors includingall fittings complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
7S&F110mm bore PVC (SWR) bends any radius With access door complete all as specified and as directed.
8S&F110mm PVC (SWR) junction single, (Single T) equal or unequal.with access door complete all as specified and as directed.
9S&F75mm bore PVC (SWR) bends any radius With access door complete all as specified and as directed.
10S&F 75mm PVC(SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
11S&F 75mm bore( SWR) vent cowl complete all as specified and as directed.
12S&FPVC (SWR) reducers 110mmcomplete all as specified and as directed.
13M&L for demolition of cement Concrete (unreinforced) of any description and in anypositionnot otherwise specifically provided for complete all as specified and as directed.
14Excavation in trenches n.exc 1.50 m wide and n.exc 1.50 m in depth for foundation or shafts, wells, cesspits, manholes, pier holes,cable laying, sewage/water lines etc complete and getting outin soft/loose soil complete all as specified and as directed.
15Demolition and breaking of drain pipes of 150 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all as specified and as directed.
16M&L for reinforced cement concrete drain pipes of 150 mm dia bore class NP-2, laid and jointed complete with collars etc complete all as specified and as directed.
17M&L for concrete bed of thickness 100mm to drain pipes 150 mm bore including packing under and hunching against the sides of pipe, after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregagte) etc complete all as specified and as directed.
18Returning filling in including spreading leveling watering and well ramming in layer not exc 25cm thick complete all as specified and as directed.
19Removal of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and as directed.
20M&L for Cement concrete in filling and mass concrete Type B0 1:2:4(12.5 mm graded aggregate) complete all as specified and as directed.
21M&L for Cutting into existing manholes for connecting new/existing drains, making good to pipe and rendering , cutting out existing benching for and forming branch channel in cement conc 1:2:4 type B-1 smooth finished and making good benching for 150 mm bore SGSW sewage pipe complete all as specified and as directed.
22Dismantling of brickwork or stone boulder masonry, built in cement mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
23M&L for Brick work with sub class ‘B’ bricks(old size brick), straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:4) and external face of brick work pointed flush in the same mortar as the work proceeds, complete all as specified and as directed.
24M&L for Rendering 15 mm thick on brickor concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and as directed.
25M&L for preparing newly Plastered surfaces of Walls by applying 1 mm Wall Putty, cutting/rubbing to obtained a Smooth Surface and applying Two Coats of Acrylic Weather Coat Exterior Paintwith approved Tint over a coat of Primer (as per Manufacturer"s instructions), complete all as specified and as directed.
26S&F polycarbonate roofing of thickness 10mm with sides lap fixed with coach screws and washers in roof, walls, MS structure including wind ties wherever required and including taking down existing sheeting complete all as specified and as directed.
27M&L for preparing old treated steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and as directed.
28Taking up or down steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches complete all as specified and as directed of sizes :-
29(a) 15mm bore.
30(b) 20mm bore .
31(c) 25mm bore .
32(d) 40mm bore .
33(e) 50 mm bore .
34(f) 80 mm bore .
35(g) 100 mm bore .
36S & F in repair steel tubing and connectionsincluding all fittings such asbends, belows tee, unions, sockets etc laid complete in trenches complete all as specified and as directed of sizes :-
37(a) 15mm bore.
38(b) 20mm bore .
39(c) 25mm bore .
40(d) 40mm bore .
41(e) 50 mm bore .
42(f) 80 mm bore .
43(g) 100 mm bore .
44S & F in replacement Gun metal Gate valvewith iron wheel headscrewed both ends complete all as specified and as directedof sizes :-
45(a)50 mm dia.
46(b)40 mm dia.
47(c)20 mm dia.
48(d)15 mm dia.
49Taking down CI pipe 150 mm bore including connections and all fittings, U/S Lead complete all as specified and as directed.
50Supply, Laying and Testing 150mm DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints Class K9in any length laid in trenches complete all as specified and as directed.
51M&L for CIBends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction,double branch cross (all sockets or scocket and spigot) collars, Tail piece, caps and plugs upto 150 mm bore CI pipe complete all as specified and as directed.
52M&L for boring/auguring (upto 6mtr span) suitable hole and insertion of 50 to 150mm dia pipe not less than 600mm below existing PCC/Road/hard standing complete all as specified and as directed. Note: Pipe will be paid in saperate item.
53M&L for PCC 1:3:6 type C2 using (40 mm graded stone aggregate ) for making good distrubed road surfaces and pole foundation including necessary use and waste of form work complete all as specified and as directed.
54S&F cast iron flanged drilled heavy duty sluice valve of size 100 mm bore with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion, nuts and bolts with washers etc includingtaking downold unserviceable sluice valve of size 80 from existingposition after removing out nuts/bolts etc complete all as specified and as directed. Note.Nuts and bolts,gasket is included in the unit.
55S&F cast iron flanged drilled heavy duty sluice valve of size 150 mm bore with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion, nuts and bolts with washers etc includingtaking downold unserviceable sluice valve of size 80 from existingposition after removing out nuts/bolts etc complete all as specified and as directed. Note.Nuts and bolts,gasket is included in the unit.
56Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified for the 900mm x 750mm x 900mm size.
57Repairs/Maint & Servicing ofAutomaticoperation servo controlled, oil cooled, 3 phase Volage Stabilizer15 KVA capacity complete all as specified and as directed comprising with the following Works:- (a)Taking proper shut down in writing/disconnecting up the Incoming and outgoingcable connections and earthing connections from volatge stabilizer and LT panels. (b)Removing theVolage stabilizer from platform and shifting to suitable place/ building /shed with the help of crane/hydra/Chain pully etc as requiredat site(Required plant/machiery of any capacity shall be in the scope of contractor). (c)Drain out transformer oil and storing in suitable container and keep at safe place for refilling. (Container required for serviceable/unserviceable oil received from draing out from voltage stabilizer will be in scope of otractor) (d) To carry outinspection internally byopening top cover by removing nuts, bolts and washers and all mounting accessories. (e)Cleaning the tank internally with suitable clothes before refilling the transformer oil. (f) Refilling the new/serviceable oilafter complete repair. (g) Replacement of worn out parts such as Dimmer coil, transformer, etc includingliftting out /lowering downthe core(Burnt out/unsv parts paid under respective item of schedule. (h) Reassembling the same and shifting back to the plateform and connecting all incoming/outgooing cable/earthing connections etc andincluding testing on load on completion of job complete all as specified and as directed. Note : Any T & P required to faclitate the repair will be in the scope of contractor.
58Supply only Volmeter 0-300 V, 72/96 mm complete all as specified and as directed.
59Supply only Amp meter 0-1000 A with set of 1000/5A CTs complete all as specified and as directed.
60Supply only carbon complete all as specified and as directed.
61Supply onlyServo circuit PCB complete all as specified and as directed.
62Supply onlyServo control Panel complete all as specified and as directed.
63Supply only Electronic control panel with servo card.(Servo control Box) complete all as specified and as directed.
64Supply only Dimmerstate unit 15 amp complete all as specified and as directed.
65Supply only servo motor 3 Kg with RC complete all as specified and as directed.
66Supply only Main Transformer complete all as specified and as directed.
67Dehydration and filteration ofvoltage stabilizer oilwith filtration machine and heating system to get di-electric strength of oil 60 kV minimum complete all as specified and as directed.
68Supply only new transformer oil of dielectric strength not be less than 60kV and conforming to IS-335 of 1993 for filling / topping up oil of transformer up to disired level complete all as specified and as directed.