}

Supply Of Essential Surgical Items, Kamrup Metro-Assam

Health And Family Welfare Department has published Supply Of Essential Surgical Items. Submission Date for this Tender is 10-04-2024. Injection and Aspiration Needles and Accessories Tenders in Kamrup Metro Assam. Bidders can get complete Tender details and download the document.




Tender Notice

42766274
Corrigendum : Supply Of Essential Surgical Items
Open Tender
Indian
Assam
Kamrup Metro
10-04-2024

Tender Details

Supply Of Essential Surgical Items. , Absorbablegelatin Sponge Ip, Size:-80 Mm X 50Mm X 10Mm , Blood Administration Set / Blood Transfusion Set • Sharp And Easy Piercing Spike Suitable For Blood Bags And Standard Blood Containers. • Transparent Cylindrical Drip Chamber With Filter. Filter Size Should Be 200+20 Micrometer. • 150 Cm Long Smooth Kink Resistant Tubing • Efficient Roller Clamp To Control And Adjust The Transfusion Rate. , Suction Catheter, Sterile. Size: ( For Usein Respiratory Tract ) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm ( Min. ) • Size- Fg 8. , Suction Catheter, Sterile. Size: ( For Usein Respiratory Tract ) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm ( Min. ) • Size- Fg 10 , Suction Catheter, Sterile. Size: ( For Usein Respiratory Tract ) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm ( Min. ) • Size- Fg 12 , Suction Catheter, Sterile. Size: ( For Usein Respiratory Tract ) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm ( Min. ) • Size- Fg 14 , Suction Catheter, Sterile. Size: ( For Usein Respiratory Tract ) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm ( Min. ) • Size- Fg 16 , Sterilecatheter, Singleuse, For Urinary Drainage ( Foley Balloon Catheter ) , 2 Way, Size 6 Fr • Made Of Siliconeelastomer Bonded With Latex • Should Havehard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned. Specification For B, C, D, E, F, G Should Bementioned. , Sterile Catheter, Single Use, For Urinary Drainage ( Foley Balloon Catheter ) , 2 Way, Size 8 Fr • Made Of Siliconeelastomer Bonded With Latex • Should Havehard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned. Specification For B, C, D, E, F, G Should Bementioned. , Sterile Catheter, Single Use, For Urinary Drainage ( Foley Balloon Catheter ) , 2 Way, Size 10 Fr • Made Of Siliconeelastomer Bonded With Latex • Should Havehard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned. Specification For B, C, D, E, F, G Should Bementioned. , Sterile Catheter, Single Use, For Urinary Drainage ( Foley Balloon Catheter ) , 2 Way, Size 12 Fr • Made Of Siliconeelastomer Bonded With Latex • Should Havehard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned. Specification For B, C, D, E, F, G Should Bementioned. , Sterilecatheter, Singleuse, For Urinary Drainage ( Foley Balloon Catheter ) , 2 Way, Size 14 Fr • Made Of Siliconeelastomer Bonded With Latex • Should Havehard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned. Specification For B, C, D, E, F, G Should Bementioned. , Sterile Catheter, Single Use, For Urinary Drainage ( Foley Balloon Catheter ) , 2 Way, Size 16 Fr • Made Of Siliconeelastomer Bonded With Latex • Should Havehard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned. Specification For B, C, D, E, F, G Should Bementioned. , Sterile Catheter, Single Use, For Urinary Drainage ( Foley Balloon Catheter ) , 2 Way, Size 18 Fr • Made Of Siliconeelastomer Bonded With Latex • Should Havehard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned. Specification For B, C, D, E, F, G Should Bementioned. , Sterilecatheter, Singleuse, For Urinary Drainagewith Balloon, 3 Way, Size 20 F. , Sterilecatheter, Singleuse, For Urinary Drainage With Balloon, 2 Way, Size 20 F. , Sterilecatheter, Singleuse, For Urinary Drainage With Balloon, 3 Way, Size22 F , Sterilecatheter, Singleuse, For Urinary Drainage With Balloon, 2 Way, Size22 F , Infant Feeding Tube Size: 4Fg Length 50 Cm ( Min. ) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexiblemount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:5 Fg Length 50 Cm ( Min. ) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexiblemount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:6 Fg Length 50 Cm ( Min. ) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexiblemount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:8Fg Length 50 Cm ( Min. ) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexiblemount With In-Built Closure • Radio Opaque Line • Sterile , Infant Feeding Tube Size:10Fg Length 50 Cm ( Min. ) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexiblemount With In-Built Closure • Radio Opaque Line • Sterile , Sterile Disposableperfusion Set With Airway And Needle ( Adult Use ) • For Gravity Feed Only • Sharp And Easy Piercing Spike With Air Vent • Transparent And Flexible Drip Chamber • 150 Cm Long Smooth Kink Resistant Tubing • Self Sealing Latex Bulb Which Will Also Act As An Port For Extra Medication • Efficient Roller Clamp To Control And Adjust The Fluid Rate • 21 G Needle. , Sterile Disposableperfusion Set ( Infusion Set ) With Airway And Needle ( Pediatrics Use ) • Burette Type Measured Volume Chamber Of 100 Ml • Drop Size Of Approx 60 Drops Per Ml • Injection Port, Latex Free, For Intermittent Medication. • Floating Auto Shut Off Valve ( Latex Free ) In Burette. • Soft And Kink Resistant Pvc Tubing. • Roller Controller For Flow Control • Tubelength 150 Cm • 23G Needle , Steriledisposable Infusion Set With Micro Drip ( I.V. ) • Micro Drip Infusion Set With Drop Sizereduced To Approx 60 Drops Per Ml • Sharp And Easy Piercing Spike • Transparent And Flexible Drip Chamber • 150 Cm Long Smooth Kink Resistant Tubing Efficient Roller Clamp To Control And Adjust Thefluid Rate , Insulin Syringe ( Graduation Up To 40 Units ) With Fixed 30G Needle. , Steriledisposable ( Singleuse ) Ptfe 2 Way Iv Cannula, 16 G, Standard Blister Pack. , Steriledisposable ( Singleuse ) Ptfe 2 Way Iv Cannula , 18 G, Standard Blister Pack. , Steriledisposable ( Singleuse ) Ptfe 2 Way Iv Cannula, 20 G, Standard Blister Pack. , Steriledisposable ( Singleuse ) Ptfe 2 Way Iv Cannula, 22 G, Standard Blister Pack. , Steriledisposable ( Singleuse ) Ptfe 2 Way Iv Cannula, 24 G, Standard Blister Pack. , Oxygen Mask ( Adult ) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On Themouth And Nasal Area • Friendly Soft Medical Pvc Material Fitting Better And More Comfortable. • Aluminum Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. , Oxygen Mask ( Paediatric ) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On Themouth And Nasal Area • Friendly Soft Medical Pvc Material Fitting Better And More Comfortable. • Aluminum Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. • Mask Connector 4M , Plaster Of Paris Bandages Bp 15Cm X 2.7 Mts , Plaster Of Paris Bandages Bp 10Cm X 2.7 Mts , Ryles Tube / Nasogastric Tube ( Pvc ) With Radio Opaque Lining Size:- 8 Fg , Ryles Tube / Nasogastric Tube ( Pvc ) With Radio Opaque Lining Size:- 10 Fg , Ryles Tube / Nasogastric Tube ( Pvc ) With Radio Opaque Lining Size:- 12 Fg , Ryles Tube / Nasogastric Tube ( Pvc ) With Radio Opaque Lining Size:- 14 Fg , Ryles Tube / Nasogastric Tube ( Pvc ) With Radio Opaque Lining Size:- 16 Fg , Ryles Tube / Nasogastric Tube ( Pvc ) With Radio Opaque Lining Size:-18 Fg , Auto Disablesyringe 1 Ml With 23G-28 G Needleof 1 Inch, Ribbon Pack , Sterile Hypodermic Syringe With Needleattached, 25G - 28G, Singleuse- 1 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimize Friction During Movement & Prevent Leakage And Back Flow • Sharp Needleensuring Minimum Trauma During Penetration • Packing: Needleshould Be Attached With Thesyringe And Packed In Unit Ribbon / Blister Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container , Sterile Hypodermic Syringe With Needle Attached, 24G, Single Use - 2 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimize Friction During Movement & Prevent Leakage And Back Flow • Sharp Needleensuring Minimum Trauma During Penetration • Packing: Needleshould Be Attached With Thesyringe And Packed In Unit Ribbon / Blister Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container , Sterilehypodermic Syringe With Needle Attached, 24G, Single Use - 5 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimize Friction During Movement & Prevent Leakage And Back Flow • Sharp Needleensuring Minimum Trauma During Penetration • Packing: Needleshould Be Attached With Thesyringe And Packed In Unit Ribbon / Blister Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterilehypodermic Syringe With Needle Attached, 22G, Single Use - 10 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimize Friction During Movement & Prevent Leakage And Back Flow • Sharp Needleensuring Minimum Trauma During Penetration • Packing: Needleshould Be Attached With Thesyringe And Packed In Unit Ribbon / Blister Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe With Needleattached, Single Use - 20 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimize Friction During Movement & Prevent Leakage And Back Flow • Sharp Needleensuring Minimum Trauma During Penetration • Packing: Needleshould Be Attached With Thesyringe And Packed In Unit Ribbon / Blister Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe Single Use 50 Ml For Fitting In Infusion Pump. • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimize Friction During Movement & Prevent Leakage And Back Flow • Packing: Packed In Unit Ribbon / Blister Pack. • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Surgical Bladesterile, Size10 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Beno Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. • The Surfaces Of Thebladeshall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. , Surgical Blade Sterile, Size 11 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Beno Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. • The Surfaces Of Thebladeshall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. , Surgical Bladesterile, Size15 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Beno Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. • The Surfaces Of Thebladeshall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. , Surgical Blade Sterile, Size 20 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Beno Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. • The Surfaces Of Thebladeshall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. , Surgical Blade Sterile, Size 22 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Beno Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. • The Surfaces Of Thebladeshall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. , Surgical Blade Sterile, Size 23 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Beno Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. • The Surfaces Of Thebladeshall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. , Surgical Bladesterile, Size24 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Beno Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. • The Surfaces Of Thebladeshall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. , Steriledisposable Spinal Needle For Singleuse 20 G , Steriledisposable Spinal Needle For Singleuse 21 G , Steriledisposable Spinal Needle For Singleuse 22 G , Steriledisposable Spinal Needle For Singleuse 23 G , Steriledisposable Spinal Needle For Singleuse 25 G , Urinecollection Bag, Disposable, 2000 Ml With Comfortable& Quality Straps. , Urinecollection Bag, Disposable, 2000 Ml With Flow Meter , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 2.5 , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 3.0 , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 3.5 , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 4.0 , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 4.5 , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 5.0 , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 5.5 , Endotracheal Tube Plain With Radio Opaque Line , Sterile, Single Use, Size 6.0 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 4 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 4.5 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 5.0 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 5.5 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 6.0 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 6.5 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 7.0 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 7.5 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 8.0 , Endotracheal Tube Cuff With Radio Opaque Line, Sterile, Single Use, Size 8.5 , Tracheostomy Tube ( Pvc ) Plain, Sterile, Single Use, Size:- 2.5 , Tracheostomy Tube ( Pvc ) Plain, Sterile, Single Use, Size:- 3 . , Tracheostomy Tube ( Pvc ) Plain, Sterile, Single Use, Size:- 3.5 , Tracheostomy Tube ( Pvc ) Plain, Sterile, Single Use, Size:- 6.5. , Tracheostomy Tube ( Pvc ) Plain, Sterile, Single Use, Size:- 7. , Tracheostomy Tube ( Pvc ) Plain, Sterile, Single Use, Size:- 7.5. , Tracheostomy Tube ( Pvc ) Cuff, Sterile, Single Use, Size:- 6.5. , Tracheostomy Tube ( Pvc ) Cuff, Sterile, Single Use, Size:- 7. , Tracheostomy Tube ( Pvc ) Cuff, Sterile, Single Use, Size:- 7.5. , Abdominal Drain Kit , Sterile, Having Drainage Catheter And Collecting Bag 2000 Ml, Size 24. , Abdominal Drain Kit , Sterile, Having Drainage Catheter And Collecting Bag 2000 Ml, Size 28. , Abdominal Drain Kit , Sterile, Having Drainage Catheter And Collecting Bag 2000 Ml, Size 32. , Closed Wound Drainagedevice Under Negativepressure ( Closed Wound Suction Unit ) Size Of Minimum Of 200Ml Capacity, Catheter, Size-10. , Closed Wound Drainagedevice Under Negativepressure ( Closed Wound Suction Unit ) Size Of Minimum Of 200Ml Capacity, Catheter, Size-12. , Closed Wound Drainagedevice Under Negativepressure ( Closed Wound Suction Unit ) Size Of Minimum Of 200Ml Capacity, Catheter, Size-14. , Adhesive Plaster 7.5 Cm X 10 Meters , Bone Marrow Biopsy Needle ( Disposable ) 11 G , Paper Adhesive Plaster 1” X 9 Meter , Paper Adhesive Plaster 2” X 9 Meter , Paper Adhesive Plaster 3” X 9 Meter , Paraffin Gauge Dressing Bp, Size: - 10Cm X10cm X 1’S Dressing. ( 1 Single Pouch Of 1Dressing ) . , Chest Tube Size12f , Chest Tube Size16f , Chest Tube Size20f , Chest Tube Size24f , Chest Tube Size28f , Chest Tube Size32f , Elastic Adhesive Bandage 10 Cm X 1 Meter Bp, Flesh Colored. , Sterileauto Disabled Disposable Blood Lancet With Plastic Handle30g, Penetration Depth To Suit Capillary Blood Requirement, ( Per Box Should Contain 100 Picee ) , Nasal Oxygen Cannula ( Set ) , Twin Bore ( Accessory For Compressed Air Breathing ) All Sizes ( Adult ) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volumeof Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source Tube Length 200 Cm , Nasal Oxygen Cannula ( Set ) , Twin Bore ( Accessory For Compressed Air Breathing ) All Sizes ( Pediatrics ) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volumeof Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source Tube Length 200 Cm , Central Venous Catheter Double Lumen, Size :- 7 Fr. X 16 / 13-20 C.M. , Central Venous Catheter Triplelumen, Size: - 7 Fr. X 16 / 13- 20 C.M. , Central Line Two Way , Central Line Three Way , Universal Re-Usable Patient Return Pad For Diathermy 36L X 20W X1 / 8 Thickness Used For All Patients Weight >350Gms Capacity , Disposablediathermic Open Pencils With Ptfe Coated Pencil 16.5Cm / 10.2Cm , Disposablediathermic Open Pencils With Ptfe Coated Button Switch Pencil With Blade& Holster , Disposablediathermic Open Pencils With Ptfe Coated , 5.1Cm 45 Degree , Laparoscopic Electrodes With Ptfe Coated, 33Cm Spatula / Curved / L-Hook / J-Hook , Laparoscopic Electrodes With Ptfe Coated, 45Cm Curved / L- Hook / J-Hook , Disposablediathermic Open Pencils With Ptfe Coated Pencil 6.35Cm , Multi Clip Applier Preloaded 24Cm With 20 ( Small Size ) Titanium Clips With 30 Degreejaw Angle , Multi Clip Applier Preloaded 29Cm With 30 ( Medium Size ) Titanium Clips With 30 Degreejaw Angle. , Multi Clip Applier Preloaded 34Cm With 20 ( Largesize ) Titanium Clips With 30 Degreejaw Angle , Umbilical Cord Clamp, Plastic, Sterilized With Permanent Locking , K -90 Catheter , Iv Cannula Fixator ( Adhesive ) Madeof High Strength And Extra Breathableelastic Fabric, Uniformly Coated With Hypoallegic, Anti Fungal, Non Irritant Adhesive. Sterilepacked In Peelable Pouch Pack , Nebulization Mask ( Adult ) , Nebulization Mask ( Pediatric ) , Sterilescalp Vein Set ( Disposable ) , Size 18G. , Sterilescalp Vein Set ( Disposable ) , Size 20G. , Sterilescalp Vein Set ( Disposable ) , Size 22G. , Sterilescalp Vein Set ( Disposable ) , Size 24G. , Corrugated Drainage Sheet , Sterile , Multichannel With Radio Opaque Line, Singleuse, All Sizes , Bonemarrow Biopsy Needle ( Disposable ) 13 G , Bonemarrow Aspiration Needle ( Disposable ) 14G , Bonemarrow Aspiration Needle ( Disposable ) 16 G , Bonemarrow Aspiration Needle ( Disposable ) 18G , Ambu Bag Neonate 250 Ml , Ambu Bag Pediatric 500Ml , Ambu Bag Adult 1000 Ml , Sterile Disposable Airway Size 1 , Sterile Disposable Airway Size 2 , Steriledisposable Airway Size 3 , Pressure Monitoring Line / High Pressure Extension Line ( Pmo Line ) Length 150 Cm , Pressure Monitoring Line / High Pressure Extension Line ( Pmo Line ) Length 200 Cm , Bain’S Circuit , Jackson & Rees Modification Of Ayer’S T Piece , Water Seal Drainagebag , Collagen Sheet , Anti Microbial Incise Drapes ( 35 C.M X35 C.M ) , Sterilepacking. , Anti Microbial Incise Drapes ( 60 C.M X45 C.M ) , Sterilepacking. , Elastic Crepe Bandage, Size: - 4 Inches X 4 Meters ( Stretchable Length, Supplied With Two Clips And Non-Fraying Edges ) , Individual Pack. , Elastic Crepe Bandage, Size: - 6 Inches X 4 Meters ( Stretchable Length, Supplied With Two Clips And Non-Fraying Edges ) , Individual Pack. , Soft Roll Bandage For Plaster Padding Non Allergic Size 10 Cm X 3 Meter , Soft Roll Bandage For Plaster Padding Non Allergic Size 15Cmx 3Meter

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Mar-2024 Date Extesnion Date 03-04-2024
2 02-Apr-2024 Date Extension Date 10-04-2024
3 02-Apr-2024 Technical Corrigendum Technical Bid 10-04-2024

Key Value

Document Fees
INR 2000 /-
EMD
INR 500000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail