Tender For Additional/Alternator To Officers Mess At Af Station Ambala Under Ge Af Ambala, ambala-Haryana

Military Engineer Services-MES has published Tender For Additional/Alternator To Officers Mess At Af Station Ambala Under Ge Af Ambala. Submission Date for this Tender is 03-04-2024. Building Work Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42742927
Corrigendum : Tender For Additional/Alternator To Officers Mess At Af Station Ambala Under Ge Af Ambala
Open Tender
Indian
Haryana
ambala
03-04-2024

Tender Details

Tender For Additional/Alternator To Officers Mess At Af Station Ambala Under Ge Af Ambala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 87320.0 /-
Tender Value
INR 43.66 Lakhs /-

BOQ Items

Name of Work: ADDN/ ALTN TO OFFICER"S MESS AT AF STN AMBALA UNDER GE (AF) AMBALA
Sl. No. Item Description
1Surface excavation not exceeding 30 cm deep and averaging 15 cm deep in soft/loose soil & getting out including clearing all grass vegetation, saplings, shrubs, brush woods under growth roots and trees not exceeding 30 cm girthincluding complete removal of surplus soil complete all as specified and as directed.
2Excavation over areas for foundation in soft/loose, soil not exceeding 1.5m deep and getting out complete all as specified and as directed..
3Returning filling in, including, spreading, leveling watering and well ramming in layers not exceeding 25 cm thick each,complete all as specified and as directed.
4Removing excavated soil (excavated material) not exceeding 50 mtr and depositing where directed at a level notexceeding 1.5 mtr above the starting point, complete all as specified and as directed.
5M&L for formwork to sides of rough finished surfaces of concrete foundation, footings, bases of columns, raft and raft beams and soffits (if any) of foundationand similar work, vertical or to batter, to achieve rough finished surface of concrete flat complete all as specified and as directed.
6M&L for formwork to sides of flat rough finished to sides of columns complete all as specified and directed.
7M&L for formwork to sides and soffits of roof beam/lintel beam sides and soffits flat rough finished complete all as specified and directed.
8M&L for formwork for slab and chajja complete all as specified and as directed.
9M&L for brick work with sub class "B" fly ash bricks, straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
10M&L for reinforced cement concrete of grade M-25 (design mix) as in foundation bases for columns and mass concrete etc all as specified and directed.
11M&L for reinforced cement concrete of grade M-25 (design mix) as in as in columns, posts & struts etc etc complete all as specified and as directed.
12M&L for reinforced cement concrete of grade M-25 (design mix) as in beam etc complete all as specified and as directed.
13M&L for reinforced cement concrete of grade M-25 (design mix) as in Slab etc complete all as specified and as directed.
14M&L for steel deformed bars (TMT bars) 10mm dia and over in reinforcement for concrete, cut to length, bent to required shape including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to Fe 500 or Fe 500D complete all as specified and directed.
15M&L for steel deformed bars (TMT bars) 8 mm dia, cut to length, bent to required shape including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to Fe 500 or Fe 500D complete specified and directed.
16All as per BOQ Srl item No. 15.00 here-in-above but 8mm dia and over upto and including 10mm dia in striupps as in stirrups, spacers, binders, ties etc complete all as specified and as directed.
17M&L for plain cement concrete 1:3:6, type C-2, (using 40mm graded mechanically crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and and as directed.
18M&L for 100 mm thick plain cement concrete 1:4:8 type D-2, (using 40mm graded mechanically crushed stone aggregate) as in sub base complete all as specified and and as directed.
19M&L for External Plaster, 15mm thick in cement mortar 1:4 on brick or concrete surfaces surfaces finished fair & even without using extra cement complete all as specified and as directed by Engr-in-charge
20M&L for Internal Plaster, 15mm thick in cement mortar 1:6 on brick or concrete surfaces surfaces finished fair & even without using extra cement complete all as specified and as directed by Engr-in-charge
21M&L for 5mm thick in cement mortar 1:3 as in soffits and ceilings complete all as specified and as directed by Engr-in-charge
22M&L for Machine cut kota stone slab flooring (550 mmx 550 mm) 20-22 mm thick laid over & including 20 mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish ) complete all as specifed and directed by Engr-in-charge
23M&L for Machine cut Kota stone slab flooring 18-20 mm thickskirting, dado and pillar, laid over & including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge.
24M&L for prepration ofnewlyplastered surface of any description and applying two coats of oil based distemper over a coat of 1mm thick wall care putty complete all as specified and directed by Engr-in-charge.
25M&L for preparation of plastered surfaces of wall & applying two coat of white washcomplete all as specified and directed.
26M&L for preparing newly plastered surface of walls and applying two coats of exterior acrylic paint (water based) over a coat of primer of any shade and pattern complete all as specified and directed.
27M&L for Green Plaster, 15mm thick in cement mortar 1:4 on newly casted slab complete all as specified and as directed by Engr-in-charge
28M&L for Cleaning of dust Removal from all loose existing bituminious material manually and with heat torch gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with Highly elastic Bituminous cold applied putty of Tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or equivalent make as approved by GE cold applied, Bituminous Mortar & Cold Emulsion cum waterproofing Liquid ofShalikote-T-10 or equivalent make of approved by GE, Created SSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ration of 1 :1 and apply @400gm per Sqm (As per Surface Conditions). Apply first coat of Tarfelt LM or equivalent make of approved by GE having elongation 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days 0.50 mm conforming to ASTM-C-412 with no diluation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm. Lay Geotex of 45 GSM/ Fibre mesh simultaneously and paste it properly with overlap of 50mm. Allow the first coat to dry for 10 to 12 Hrs. Apply 2nd coats on cured first coat with consumption @ 700gm per Sqm in opposite direction of first coat by Brush or Roller. Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm per Sqm.
29Ensure final curing time of 36 hrs before allowing/ carrying out any further work. Conduct ponding test after min 7 day applying two coats of U V Resistant Elastomeric Exterior Acrylic Weather resistant water proof coatingof Shalicryl-215 or equivalent make of approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D- 6083-- for U V Protection of Bituminous Elastomeric Acrylic Emulsified Liquid Membranc of Tarfelt LM or equivalent make of approved by GE to give long life and prevent its deterioration from sunlight. Note:-(i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) 10% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years.However contractor may deposite the FDR of same amount in favour of GE.If contractor fail to rectify the defect pointed out during this period in writting,the defect shall be got rectified at contractor"risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee.Contractor"s quoted rate for this item shall deemed to be inclusive of this aspect.
30S&F Toughened glass 12 mm thick as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, complete all as specified and as directed.
31S&F Toughened glass as in windows, partitions and similar work including cutting to shape, drilling holes required, complete all as specified and as directed.
32S&F Powder Coated(min thickness of coating shall be 50micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
33M&L for 75 mm thick plain cement concrete type C-2, 1:3:6 ( using 20 mm graded mechanically crushed stone aggregate) as in path/pavings/plinth protectionetclaid in bays including finishing the concrete surface even and smooth without using extra cement complete all as specified and directed.
34M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
35M&L for machine pressed precast concrete with grey cement and pigment interlocking paver block any shape and size comforming to IS 15658-2006 of 60 mm thickness M-35 grade complete all as specified and directed by Engr -in - Charge.
36Supply and fixing in repair 20mm dia mild steelpowder coated curtain rods with wall thickness 1mm including mild steel powder coated, bracket, holding and funnel on ends as fixed in repairs complete all as specified and directed.
37Concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathedcable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly complete all as specified and directed
38One light/fan point controlled by one switch 6 amp one way, complete all as specified and directed
39One 3 pinsocket5 amp on the independent board, complete all as specified and directed
40One 3 pinsocketon same board with other switches, complete all as specified and directed
41All as per BOQ srl item No. 36.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed
42Supply and fix switch piano modular type 5 amp single pole flush type one way complete all as specified and directed.
43Supply and fix switch piano modular type 15 amp single pole flush type one way complete all as specified and directed.
44Supply and fix socket outlet modular type 3 pin 5 amp multi pin flush type complete all as specified and directed.
45Supply and fixsocket outlet modular type 6 pin 15 amp multi pin flush type complete all as specified and directed.
46S&F ceiling rose 65x17mm of three terminals complete all as specified and directed
47Supply and fix modular cover plate with frame for 1 module complete all as specified and directed
48Supply and fix modular cover plate with frame for 3 module complete all as specified and directed
49Supply and fix modular cover plate with frame for 8 module complete all as specified and directed
50Supply and fix modular metal flush box 1/2 module complete all as specified and directed
51Supply and fix modular metal flush box 3 module complete all as specified and directed
52Supply and fix modular metal flush box 8 module complete all as specified and directed
53S&F 1X18 watt wall mounted, new generationLED T-8 Retro fit for multopupose application with LED Rod , made from extruded aluminium housing,polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
54S&F ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1200mm sweep , Min air delivery 210CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as directed. Note:- Rate for writingMES NO on C/Fan is deemed to be included in quoted rate.
55Supply & fix exhaust fans AC single phase 230/ 240 V of size 250 mm sweepMade of sturdy engineering plastic with louver,shutter complete incluing making of hole/niche of suitable size along with all fixing accessories, complete all as specified and directed Note: Rate for writing MES No. on exhaust fan is deemed to be included in the quoted rate.
56Supply and fixing metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall complete all as specified and directed
57M&L submain wiringwith 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper complete all as specified and directed Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length.
58M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper complete all as specified and directed Note : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length.
59S&F MCB DB SPN 8 Way factory made IP 43 protection class metal double doorwith 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed
60S&F sheet metal enclosures for 4 way MCCB incomer + 12 module outgoings , vertical TPN load line distribution board with provn of mounting including MCCB 100amp incomer double door IP 56 protection As per IS 8623-III, 160 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed.
61S&F MCBs240/415 Volts 10 KA finger proof terminal, C curve bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB . Note: DB will be measured and paid separately under respective items of sch A-
62MCB SPN 40 Amps.
63MCB SP 5 to 32 Amps
64M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note:-Rate are deemed to be included in quoted rate for Laying of protection pipe in PCC Floors & wall and making good damages, complete all as specified and directed. Note: (i) cost of earth strip and GI pipe for protection of earth strip deemed to be included in unit rate up to 7.5 meter. (ii) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor till desired earth resistance is not obtained without accruing any extra cost to the Department.
65Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n.exc 1.5 m depth for laying of cable all specified and directed by Engr-in-charge
66M&L for fine dry river sand cusioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then puning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed. Note: Only punned down thickness of 18cm sand shall be considered for payment purpose.
67M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed
68Supplying, laying, jointing and testing underground cableXLPE insulated screenedGI Strip armoured and PVC bedded LT 1100 volts grade (heavy duty) with aluminium conductor 50 sqmm 3.5 Core,laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
69M&L for making bore below the road for crossing the GI pipe light grade 40 mm dia for cable protection and fill the putty on bothsides of the GI pipe after crossing the armoured cable to avoid the water insidecomplete all as specified and directed
70S&Ftubing light grade galvanised with all fitting laid in road/ with pole /trenches size 40 mm complete all as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail