Military Engineer Services-MES has published Tender For Repairs / Maintenance Of Fire Fighting Services, Fire Alarm System And Connected Misc Works At Cad Pulgaon. Submission Date for this Tender is 28-03-2024. Alarm Systems Tenders in pulgaon Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Mar-2024 | Corrigendum_01 | BOQ | 28-03-2024 |
Sl. No. | Item Description |
1 | Upkeep offollowing equipment /machinery installed at pump house in/near building No. P-6 comprising offoam sprinkler and water sprinkler system for cooling and washing of floor, stainless steel piping with large No of opening to maintain the required discharge of water, regular flow of foam for detecting defective items and periodical minor repairs such as oiling, greasing, rubber gaskets and providing glands and all as necessary minor repairs required for proper functining of equipments complete all as specified and as directed including all the items listed in below:- |
2 | Automatic foam sprinkler system including stainless steel tank complete and filling of foam as per direction. |
3 | Centrifugal pumping set electric driven -01 set |
4 | Standby diesel engine operated centrifugal pumping set auto/manual start- 01 set |
5 | Jockey centrifugal pump electric drivenauto/manual start- 01 set |
6 | Sluice valves, NRVs off sizes alongwith pipe line |
7 | LT Panel Board with all accessories and power cables. |
8 | Note:- (i) Testing will be carried outon Monthly basis and contractor submit the test report duly signed by users rep every month and all as specified and directed by Engr-in-charge .Testing shall be measured and paid separately. (ii)The rates of Oil, grease, rubber gaskets, and gland are deemed to be incl in above quoted rates. (iii) Anywelding work , cutting of exisitng pipes inserting MS/GI / CIfittings , replacing steel pipe , sprinkler is deemed to be incl in above quoted rates. (iv) Documents as specified are maintined and put to EIC monthly. (v) Contractor shall arrange transportation of foam drum from AGE E/M store to Pump houseand filling of foam in stainless steel tank insatalled at above bldgs deemed to included in above quoted rates. (vi) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in supply and fix in repairs. Note:- The Rate mentioned in Item No 1 For1 Year Duration. Panel recovery of Rs 2000 Per Month shall be recovered if contractor fails to testing on monthly basis at due time. |
9 | All as per item No 1 ……………. but for buildings No P-14 complete all as specified and directed. |
10 | Upkeep offollowing equipment /machinery installed at pump house in/nearbuilding No P-1 water sprinkler system for cooling & washing of floor of bldg No P-1,P-10 comprising of stainless steel piping with large No of opening to maintain the required discharge of waterfor detecting defective items and periodical minor repairs such as oiling, greasing, rubber gaskets and providing glands and all as necessary minor repairs required for proper functioning of equipments complete all as specified and as directedincluding all the items listed in below:- |
11 | Cetnrifugal pumping set electric driven -02 set |
12 | Sluice valves, NRVs off sizes alongwith pipe line |
13 | LT Panel Board with all accessories and power cables. |
14 | Note:- (i) Testing will be carried out on monthly basis and contractor submit the test report duly signed by users rep every month and all as specified and directed by Engr-in-Charge. Testing shall be measured and paid separately under respective items. (ii) The rates of Oil, grease, rubber gaskets, and gland are deemed to be included in above quoted rates. (iii) Anywelding work , cutting of exisitng pipes inserting MS/GI / CIfittings , replacing steel pipe , sprinkler is deemed to be incl in above quoted rates. (iv) Documents as specified are maintined and put to Engr-in-Charge monthly. (v) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in supply and fix in repairs. (v) The quoted rate shall cover for entire period of 365 days(including Sunday and Holiday). Note:- The Rate mentioned in Item No 3 For1 Year Duration. Panel recovery of Rs 2000 Per Month shall be recovered if contractor fails to testing on monthly basis at due time. |
15 | Testing of Foam Sprinkler system installed at P-6 and P-14 sheds complete all as specified and as directed. Note: One testing in one building will be one Job |
16 | Testing of water sprinkler system installed at P-1, P-6 P-10 and P-14sheds complete all as specified and directed. Note: One testing in one building will be one Job |
17 | Supply andfix in repairs foam spray nozzle made of stainless steel (SS304) construction with 1/2 " male BSP threaded inlet. The nozzle shall have K Factor of 30/45 and shall have aeratingarrangement to give foam of expansion 1:3 to 1:6 and suitable pattern for covarage of risk area |
18 | Supply & fix in repair Conventional 24 V DC ElectronicHooter cum Flasher.Make : spencer / Honeywell / Fire Light / NotiFier/ Ravel |
19 | Supply & fix in repair15 mm (½") dia. NBCM Body chrome finishedside wall type sprinkler / Spray nozzle Medium Velocity having rating with deflector disc of conventional construction with all accessories require to install. Make: Kartar / Shah Bhogilal / HD / Newage |
20 | Maintenance repair& testing of fire hydrant system installed at bldg shed No P-1to P-17"F" sub Depot including maintenance of followingParts complete all as specified and as directed. |
21 | Fire hydrant valves from outside and inside |
22 | Fire boxes from outside and insde |
23 | Female coupling lugs and repair to spring nut |
24 | Hose reel leakage and make good the same |
25 | Gland, all rubber parts |
26 | Note:- (i) Testing will be carried out quaterly basis and contractor submit the test report duly signed by users rep every quarter and all as specified and directed. Testing charges shall deemed to be included in unit rate quoted. (ii) Oil, grease, rubber guskets, and gland are deemed to be included in above quoted rates. (iii) Any lathe work, welding work , cutting of exisitng pipes inserting MS/GI / CIfittings , replacing steel pipe , sprinkler is deemed to be incl in above quoted rates. (iv) Documents as specified are maintined and put to Engr-in-Charge monthly. (v) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately as supply and fix as and when required. (vi) M & R shall be quarterly and considered one job for one bldg. (vii) Panel recovery of Rs 3000 Per Qtr shall be recovered if contractor fails to testing on quarterly basis at due time. |
27 | Supply and fix in repairWeather proof hose cabinet of size 750 x 600 x 250 mm fabricated from M.S. angle iron sections and 18 GMS sheet with full glass door and locking arrangement suitable to accommodate - 2Nos 15 M long hoses and 1 No branch pipe and nozzle including stand of exisitng height .The cabinet shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and shall be suitably mounted. |
28 | Supply and fix in repairs SS 304 Short Branch Pipe 63 mm with necessary accessories conforming to IS : 903 ISI marked. (Make : Newage / Swati / Shah Bhogilal /. Arihant) |
29 | Supply and fix in repair of Hydrant Valve Oblique Type 63 mm complete made out of SS 304 fitted with PVC main blank cap and GI Chain IS 5290 with ISI mark complete all as specified and as directed (Make : Newage/Kartar/Shah Bhogilal / Arihant) |
30 | Supply and fix in repair Hydrant valve wheel cast iron type suitable for 63mm dia hydrant valve complete all as specified and as directed |
31 | Supply and fix in replace RRL hose pipe 63 mm dia & 15 meter long with male and female coupling with ISI mark completeall as specified and as directed. |
32 | Supply and fix in repair Hydrant cap with chain for 63mm dia hydrant valve. |
33 | M & L for painting of fire hydrantboxes with stand, Hydrant Valves and MS pipe over the ground level after preparation of old painted surface withtwo coat of exisiting colour synthetic enamelled paint complete all as specified and as directed. |
34 | Maintenance & repairs to smoke / heat detector as well as repeater automatic fire alarm system complete with fixed temperature,heat detector,main control panel cabling 24 volt SC with FRLScable with rectifier,24 volts battery with charger unit complete installed at P-1, P-6 P-10 and P-14 sheds of "F" sub depotand 104 AC shed in "B" sub depot complete all as spcified and as directed. |
35 | Supply & fix in repair ionization smoke detector from shed with base plate complete all as specified and directed. Make: System sensor / Honeywell/Fire light/ Notifier |
36 | Supply & fix in repairs heat detector in shed with base plate complete with base plate complete all as specified and directed. Make: System sensor / Honeywell/Fire light/ Notifier |
37 | Supply & fix in repairs Beam detector with Reflectors range 15 mtr x 15 mtr x 60 mtr Operating voltage 24 V DC with adjustable convex mirror(all required Accessories.) complete all as specified and as directed Make : System Sensor / Honeywell / Fire Light / Notifier |
38 | Supply & fix in repair Conventional Manual call point.complete all as specified and as directed. Make : spencer / Honeywell / Fire Light / Notifier |
39 | Supply and layin replacement of copper conductor armoured cable FRLSH of size2 corex 1.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed . Make : POLYCAB/ PLAZA/ HAVELLS. |
40 | Supply and layin replacement of copper conductor armoured cable FRLSH of size4 corex 2.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed. Make : POLYCAB/ PLAZA/ HAVELLS. |
41 | Supply and fix in replacement of 12 Volts 7 Amps maintenance free dry cell battery, complete all as specified and as directed. Make : EXIDE / AMCO / TATA GREEN. |
42 | Supply and lay in replacement of copper conductor PVC cable FRLSH of size2 corex 2.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed. Make : POLYCAB/ PLAZA/ HAVELLS. |
43 | Taking down existing pipe of any type &supply and laying MS Pipe "C" Classby of following bore all as specified and directed by Engr-in-Charge.Make:-Prakash Surya,Jindal |
44 | 200 mm bore |
45 | 150 mm bore |
46 | 100 mm bore |
47 | 80 mm bore |
48 | 50 mm bore |
49 | Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for above bore pipe deemend to including in above quoted rates |
50 | Taking down existing union and supply and inserting GI union of 50mm bore complete all as specified and directed. Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemed to in included above quoted rates |
51 | Taking down existing union and supply and inserting GI union of 25mm bore complete all as specified and directed. Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemed to in included above quoted rates |
52 | Taking down existing gate valve and supply and fix gun metal gate valve of 50mm bore all as specified and directed. Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemed to be included in above quoted rates. |
53 | Taking down existing NRVand supply and fix new Stainless steel NRV of following bore complete all as specified and directed. Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemed to be included in above quoted rates. |
54 | 50 mm bore |
55 | 100 mm bore |
56 | Taking down existing sluice valve and supply and fix new sluice valve PN 1.6 of following bore complete all as specified and directed. |
57 | 200 mm bore |
58 | 150mm bore |
59 | 100mm bore |
60 | 80mm bore |
61 | 65mm bore |
62 | Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemed to be includedin above quoted rates. |
63 | Taking down existing foot valve and supply and fix CI foot valve of latest modelof following bore complete all as specified and as directed . Make:- Normex or as equivalent. |
64 | 200 mm bore |
65 | 150mm bore |
66 | 100mm bore |
67 | Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemend to be included in above quoted rates. |
68 | Taking out the burnt electric motor of capacity 5.0 HP to 7.5 HP from existing position, transporting to civil work shop, separating the stator and rotor housing, cutting and removing the existing winding of stator completely, cleaning the slots and rewinding with existing gauge of super enamelled copper winding wire with suitable insulation, applying insulation varnish and heating in heating chamber till completely dried and reassembling the motor including supply and replacement of DE(01 No.) &NDE(01 No) bearings (make: NBC/SKF/TATA), transporting back to site and re-installing in its original position including proper alignment for smooth running and testing on completion complete all as specified and directed . |
69 | All as per item no 32.00 but for 12.5 HP to 15 HP motor |
70 | All as per item no 32.00 but for 40 HP to 15 HP motor |
71 | All as per item no 32.00 but for75 HP to 80 HP motor |
72 | M&L for taking out the defective pump set of capacity upto 5 HP to 15 HP ofAC plant fromexisting position by carefully disconnecting all water pipe lines and electrical cablesand carrying out overhauling by dismantling the pump casing, cleaning of the impeller and supply and replacement of Gunmetal bush(01 No), gland plate (01 No.) alongwith studs, nuts, gland packing rope, greasing and re-assembling and re-installing in its original position and testing on completion complete all as specified.Note:-spare parts other than mentioned above under this itemwill be measured and paid separately as supply only. |
73 | All as per item No 36.00but forpump capacity 40 HP to 80 HP |
74 | supply only end ball / roller bearing set with good quality grease suitable for pump setsupto 5 HP to 15 HPMake:NBC/SKF/Tata |
75 | supply only end ball / roller bearing set with good quality grease suitable for pump sets 40 HP to 80 HP Make:NBC/SKF/Tata |
76 | Supply only star coupling key any size as per sample complete all as specified and as directed. |
77 | supply only pump shaft suitable for pump sets 5 HP to 15 HP capacity complete all as specified and as directed. |
78 | supply only pump shaft suitable for pump sets40 HP to 80 HP capacitycomplete all as specified and as directed. |
79 | Supply only pump impeller brass suitable for pump sets5 HP to 15 HP capacity complete all as specified and as directed. |
80 | Supply only pump impeller brass suitable for pump sets40 HP to 80 HP capacity complete all as specified and as directed. |
81 | Supply only gun metal bush bearingset complete set of two as per sample for 5 HP to 15 HP Pump complete all as specified and as directed. |
82 | Supply only gun metal bush bearingset complete set of two as per sample for 40 HP to 80 HP Pump complete all as specified and as directed. |
83 | Material and labour for CI special/fittings suitable for CI flanged/socket ends pipe upto 200mm bore such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch "Y" junctin, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint etc complete including taking out old fittings complete all as specified and as directed. |
84 | Repair and Maintenance of Electric operated siren of range 3 to 5KM directly coupled with 3 HP 415 V 3 phase electric motor complete all as specified and directed . (Note Items such as PVC copper wire, lugs, thimbles, nuts, bolts, washer, PVC termination ,lathe work if any are deemend to be included in above quoted rates). Note: rewinding shall be measured and paid separately |
85 | M&L for Re-winding of motor of Electric operated siren 3 HP with exisitng sizes/ guage copper wire , testing complete |
86 | Servicing of Diesel Engine installed at P-4, P-6 and P-14 and taking out the defective/unserviceable parts and re-assembling the same after repair/replaced and testing complete all as specified and directed.(Note : U/S spare parts shall be measured and paid separately as supply only here in after). |
87 | Diesel filter exisitng size |
88 | Oil filter exisitng size |
89 | Air filter exisitng size |
90 | Fan belt exisitng size |
91 | Supply and pouring of coolant suitable for radiator as per the requirement of time to time as directed by Engr-in-charge for various capacities of DG Set complete all as specified and as directed. |
92 | Supply and filling lubrication oil SAE-40 ( 20 W- 40 grade) ofMake SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE. |
93 | Supply and fix BatteryTerminals (Positive and Negative - one set) copper 12V suitable for 100 / 120/ 180 AH as per existing complete all as specified and directed . |
94 | Supply and fix Batteryled (Positive and Negative - one set) copper not less than 1 meter with suitable for 180 AH as per existing complete all as specified and directed. |
95 | Supply and filling distilled water for exisitng power backup system complete all as specified and as directed. |
96 | M & L for paintingcomplete equipments/ machinery / pipes / valves / Elect Panels etc installed at pump house for P-1, P-6 and P-14 after prepation of old painted surface with two coat of exisiting colour synthetic enamelled paint complete all as specified and directed. |
97 | M & L for paintingcomplete equipments/ machinery / pipes / valves / Elect Panels etc installed at foam pump house ofP-6 and P-14 after prepation of old painted surface with two coat of exisiting colour synthetic enamelled paint complete all as specified and directed . |
98 | Supply, Installation in repairsTesting & Commissioning of 8 Zone Microprocessor based conventional type Fire Alarm Panel incl following items |
99 | Panel indicator LCD. |
100 | Fault Indicator |
101 | Short Indicator |
102 | Zone Isolate Indicator |
103 | System Ok Indicator |
104 | Fire Indicator |
105 | Supply Fault Indicator |
106 | Panel fabricated of 16SWG CRCA Sheet Make : spencer / Honeywell / Fire Light / Notifier |
107 | Supply and fix in replace of MCCB 3 Pole 100Amp 16kA 415VAC, 50 Hzoffixed type magnetic releaseto the existing panel board complete all as speciifed and directed.Make L&T/Havels/CG |
108 | Supply and fix in replace of MCCB 3 Pole 160 Amp 36kA 415VAC, 50 Hz offixed type magnetic releaseto the existing panel board into the existing panel board complete all as speciifed and as directed .Make L&T/Havels/CG |
109 | Supply and fix in replace of MCCB 3 Pole 200Amp 36kA 415VAC, 50 Hz offixed type magnetic releaseto the existing panel board to the existing panel board complete all as speciifed and directed .Make L&T/Havels/CG |
110 | Supply and fix in repairs MNX power contactor 3 Pole, 415 V, Current rating 70 A, 2NO + 2NC having coil voltage 240 Volts complete all as specifiedand as directed. |
111 | Supply & fix in replace MNX power contactor3 Pole, 415 V, Current rating 110 Amps, 2NO + 2NC having coil voltage 240 Voltscomplete all as specifiedand as directed.Make : L&T/Havells/CG. |
112 | Supply & fix in replace spare parts kit for 3 pole MNX power contractor 50Amps, 415 volts, with coil rating 230/415 volts,type ML-3 complete all as specifiedand as directed. Make L&T/Havells/CG. |
113 | Supply and fix in replaceBimetalicOverload relays suitable for MNX Power Contactor 50Amps, 415 volts, with coil rating 230/415 volts complete all as specifiedand as directed. of make L&T/Havells/CGtype ML-3. |
114 | Supply and fix in replaceBimetalicOverload relays suitable for MNX Power Contactor 70Amps, 415 volts, with coil rating 230/415 volts complete all as specifiedand as directed. Make L&T/Havells/CG . |
115 | Supply and fix in replace from the exisitng panel single phase preventor complete all as specifiedand as directed. |
116 | Supply and fixingof Cast Iron strainer of flange type of latest design of size 200/150 mmcomplete all as specifiedand as directed. |
117 | Supply and fixingstainless steel rope wire of size 4 mm for existing water level indicatorfor Overhead tank, Under ground sump of any height/depth complete all as specifiedand as directed. |
118 | Supply and fixingstainless steel float of free size for existing water level indicatorfor Overhead tank, Under ground sump of any height/depth complete all as specifiedand as directed. |
119 | M & L for paintingto existing water level indicator with two coatalongwith proper level markingfor overhead tank, Under ground sump of any height/depth complete all as specifiedand as directed |
120 | Supply and fixing float valve of size 25 mm for primingoverhead tank complete all as specifiedand as directed. |
121 | M&L for MS Fabrication work,made out of structural steel sections as in frame work for cable & piping ducts/MS door panels etc at sewage installation ,MS angle /flats/plain sheet of appropriate gauge ,cut to size and made to the existing shape suitable for fixing MS chequred duct cover /door panel including nut and bolts and washers ,welding bracing work bending cold or hot drilling holes for bolts in any shapes or sizes as reqired including one coat of primer and two coat of synthetic enamel paint to the entire steel surface all as specified and directed. |
122 | Material and labour for PCC 1:3:6 type C 1 (using 20 mm graded stone aggregate) for making pump , motor,hydrant foundation orany size as specified including necessary form work if any for fixing GI pipe/air termination rod complete all as specified and asdirected. |
123 | Labour includingtool & plant with any pestiside for cuttinggrass and bushes on monthly basis for general cleaning ofPump house,AC Plant , Sub Station, Lt Panel, Fire Hydrant including hose reel box, UG Sump, Overhead tank, Valve Pit Chamberand approach and path way for following locations :-. 5 meter sorrounding of building/ pump house and other connected area :- (a) Pump House & AC Plant BuildingsBuildings- 7 Nos (b) Substation Building - 6 Nos (c) UG Sump- 05 Nos (d) Over Head Tank- 02 Nos (e) LT Panel - 10 Nos (f) Fire Hydrant and hose reel boxes including path way-62 Nos (g) Valve pit chamber- 20 Nos Note:- The rate of above JOB for duration of 12 month. However the above cleaning will be done on quarterly basis. |
124 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 metre depth for foundation, laying of cables/pipes/poles etc., and getting out in soft/loose soil complete all as specified and directed. |
125 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed. |
126 | Removing excavated material/soil to a distance not exceeding 50mand depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy