Health And Family Welfare Department has published Tender For Construction Of 50 Bedded Critical Care Block Hospital At District Hospital Senapati District, Manipur, Under Pm - Abhim.. Submission Date for this Tender is 21-03-2024. Building Work Tenders in Imphal West Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

42728356
Corrigendum : Tender For Construction Of 50 Bedded Critical Care Block Hospital At District Hospital Senapati District, Manipur, Under Pm - Abhim.
Open Tender
Indian
Manipur
Imphal West
21-03-2024

Tender Details

Construction Of 50 Bedded Critical Care Block Hospital At District Hospital Senapati District, Manipur, Under Pm - Abhim.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Mar-2024 Time Extension for Construction of 50 Bedded Critical Care Block Hospital at District Hospital Senapati District, Manipur, under PM - ABHIM. Date 21-03-2024

Key Value

Document Fees
INR 25000 /-
EMD
INR 1325105.0 /-
Tender Value
INR 15.13 Crore /-

BOQ Items

Name of Work: Construction of50 Bedded Critical Care Block Hospital at District Hospital Senapati District, Manipur, under PM - ABHIM.
Sl. No. Item Description
1EARTHWORK:
2Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5M including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50M(a) All kinds of soil.
3Filling available excavated earth ( excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering lead upto 50 m and lift upto 1.5 m
4Filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete.
5STONE WORKS:
6Boulder with minimum size of 300mm for pitching at Site
7CEMENT CONCRETE WORKS:
8Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1:3:6(1 cement : 3 coarse sand : 6graded stone aggregate 40 mm nominal size )
9Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering (a) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size )
10RE-INFORCED CEMENT CONCRETE WORKS:
11Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:
12(a) 1:1:2 ( 1 cement :1 coarse sand :2 graded stone aggregate 20 mm nominal size)
13Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral staircases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with
14(a) 1:1:2 ( 1 cement :1 coarse sand :2 graded stone aggregate 20 mm nominal size)
15Reinforced cement concrete work in walls (any thickness) i/c attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement:
16(a) 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size).
17STEEL REINFORCEMENT:
18Steel reinforcement for RCC work i/c straightening, cutting, bending, placing in position and binding all complete.
19(a) Thermo-Mechanically Treated bars
20FORM WORKS:
21Providing form work i/c centering & shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete and plain concrete work in:
22Foundation, footing, bases of column etc and mass concrete.
23Column, pillar, posts and struts (square rectangle or polygon in plain).
24Lintels, beams , plinth beams,girders,bresummer and cantilever withwater proof ply12 mm thick
25suspended floor,roofslandingbalconies ans access platform withwater proof ply12 mm thick
26BRICKWORKS:
27Brick work with 1ST class burnt clay F.P.S(non modular) bricks in foundation & plinth in cement mortar 1 : 4 (1cement :4 coarse sand).
28Half brick masonrywith 1ST class burnt clay F.P.S(non modular) bricks in foundation & plinth in cement mortar 1 : 3 (1cement :3coarse sand).
29ALUMINIUM WORK:
30Providing and fixing Aluminiumdoors,windows and ventilatorsshutters and pastition etc. with EPDM rubber or neoprene gasket etc completeas per architecturaldrawings and directions of the engineer in charge(Cost of aluminium snap beadig shall be paid in basic item) with floating glass panes of 4 mm thickness
31FLOORING:
32Providing and laying vetrifiedfloor iles in different sizes (thickness to be specified by the manufacturer) with water absorption less than .08 % and conforming to IS:15622 of approved make
33Granite stone slab flooring over 20 mm ( average) thick base of cement mortar 1 : 6 ( 1 cement: 6 coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete with
34STEEL WORKS:
35Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffering, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-Charge, (for payment purpose only weight of the stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
36ROOFING & CEILING:
37Providing and fixing false ceiling at all height including providing and fixing of frames work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm ( both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having cleats of 10.5 mm at 450 mm centre to centre, shall befixed in a direction perpendicular to G.I intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I wire at every junction , including fixing perimeter channels 0.5mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre , with 25 mm long drive - all screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers cocering up to 150 mm on both sides of joint and two coats of primer suitable for both , all as per manufacture"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeters channels suitably fixed, all complete as per drawings and specification an ddirection of the Engineer in charge but excluding the cost of paintingwith :
38FINISHING:
3915mm cement plaster 1:3 (1 cement : 3 coarse sand)
4012mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement .
41Providing and applying plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
42Distempering with dry distemper ofapproved brand and manufactured two or more coats and of required shade on new work, over and including priming coat of whiting to give and even shade
43Finishing walls with water proofing cement paint of approved quality on new work (three or more coats) to give an even shade.
44Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.
45Making plinth protection 50 mmcement concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggrt. of 20 mm nominal size)over75 mm bed of dry brick ballast 40 mm niminal size well rammed ans consolidated and grouted with fine sand including finishingthe top smooth.
468 Passenger elevator
47SH:- WS & SI
48Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 metres in width as well as 10 sqm on plan i/c disposal of excavated earth lead upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed in
49Filling available excavated earth in trences,plinth, sides of foundations, etc in layers noy exceedinfg 20cm in depth,consolidating each de[posited layer by rammring and watering, lead upto 50m and lift upto 1.5m
50Providing and laying in position cement concrete of specified grade excluding the cost centering and shuttering- All work upto plinth level.
511:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
52Half brick masonry 2nd class (local 1st class) in cement mortar 1:3 (1 cement: 3 coarse sand) in superstructure.
53Providing and laying in position specified grade of reinforced cement concreteexcluding the cost centeringshuttering- All work upto plinth level.Reinforced cement concrete work in foundation footings, bases of columns etc. and mass concrete, excluding cost of centering, shuttering and reinforcement,
541:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
55Reinforced cement concrete work in beams,suspended floors, roofs having slope upto 15 degree landings, shelves & their supports balconies,chajjas, lintels, bands, plain window sill, stair cases and spiral stair cases upto floor 5 level excluding the cost of centering , shuttering finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse:3 graded stone aggregate 20mm nominal size).
56Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in
57Foundation, footings, bases of columns etc. and mass concrete.
58Flat surface……..
59i) Edges of slab and breaks in floor walls
60under 20 cm wide
61Reinforcementfor R.C.C work including straightening ,cutting, bending,placing in position and binding all complete.
62Thermo-Mechanically Treated bars.
6320 mm cement plaster 1:3 (1cement :3 coarse sand) finished with afloating coat of neat cement
64Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level.
651000 litres net capacity storage tanks
66White glazed tiles 10 mm thick in skirting risers of steps & dado on 10 mm thick cement plaster 1:3 (1 cement:3 coarse sand) & jointed with white cement slurry.
67Granite stone slab flooring over 20 mm ( average) thick base of cement mortar 1 : 6 ( 1 cement: 6 coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete with
68Providingand fixing water closet squatting pan (Indian type W.C. pan ) with 100 mmsand cast Iron P or S trap, 10 litre low levelwhiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
69Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests
70P/F urinal basin of white glazed earthen ware (Indian make) with 5 litres C.I. Automatic flushing cistern with fitting R.S. or C.I. Brackets,standard size, flush pipe spreader with brass union G.I. Clamp complete, including painting of cistern and fitting cutting and making good the wall and floors.
71a)Flat back Urinal
72464 x 355 x 265 mm
73Providing and Fixing wash basin of white glazed earthen ware (Indian make) with R.S. or C.I. brackets painted white 1 central 12.5 mm C.P. brass pillar tapes, 32 mm rubber plugs and C.P. brass chain 32 mm C.P. brass waist-of standard pattern 32 mm diameter M.I. or C.P. brass traps and unions complete i/c cutting and making good the walls (Indian fittings).
74a) 630 x 450 mm
75P/F kitchen sink white glazed vitreous china (Indian make) with R.S. or C.I. Brackets painted white, a pair of 12.5 mm C.P. brass pillar taps, 323 rubber plugs and C.P. brass chain 32 mm C.P. brass waste of standard pattern, 32 mm dia M.I. Or C.P. brass traps and unions complete i/c cutting and making good the walls indian fittings.
76Providing and fixing 600 x 20 mm SONAC.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P.brass screws (Hook type SONA)
77Providing and fixing 600 x 450 mm bevelled edge mirror of Indian make superior glass (of approved quality) quality complete with asbestos sheet ground, fixed to wooden cleat with C.P. brass screws and washers.
78Providing and fixing in position 2.5 mm diameter mosquito proof coupling of approved Municipal design.
79Centre Hole Mixer H.N. Deluxe.
80Providing and fixing M.I. union fisher
81a) 32 mm
82Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms.
83Providing and fixing a pair of white glazed earthen foot rest of standard pattern for Indian type W.C. pan.
84Providing and fixing soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
85ProvidingandfixingP.V.C.wastepipeforsinkorwashbasin including P.V.C. waste fittings complete.
86White Vitreous China Angle back wash basin size 600 x 480 mm with single 15 mm C.P. brass pillar tap
87Providing and fixing lead caulked joints to 100 mm HCI pipes
88Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
89100 mm nominal outer dia Pipes
90P/F 50 mm dia normal guage polythene pipes of approved quality complete with special flange compression type fittings (of approved make) including trenching and refilling etc (external works).
91P/F brass stop cock of superior quality
92Providing and fixing Polythene-Aluminium- Propylene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V. with carbon black havingthermal stability for hot & cold water supply,capable to with stand temperature up to 80 degree centrigate, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 m spacing. This includesthe costs of cutting chases and including testing of joints complete as per direction of Engineer in charge.Concealed work, i/c cutting chases and making good the wall etc.)
93(a)1216 (16 mm OD) pipe
94(b)1620 (20 mm OD) pipe
95(c)2025 (25 mm OD) pipe
96(d)2532 (32 mm OD) pipe
97Providing and fixing Chlorinated Polyviny Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threadedfittings. This includes jointing of pipes & fitting with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge ( External works etc.)
9850mm
99Making connection of GI distribution branch with GI main 25 mm to 40 mm diameter by providing & fixing Tees i/c cutting and threading the pipe etc complete.
100Providing and fixing C.P. bib cock of superior quality.
101(a) 20 mm diameter
102Providing and fixing brass stop cock of superior quality.
103(a)15 mm diameter (Delux Sona)
104Providing and fixing non-return value of superior quality. (32mm diameter)
105SH:- LD
106Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 cm and lift upto 1.5 metres
107Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m
108All kinds of soil
109Providingandlayinginpositioncementconcreteofspecified grade excluding the cost of centering and shuttering - All work upto plinth level
1101:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size)
111Providing and laying cement concrete in retaining wall,return walls(any thickness) including attached pilasters,columns,piers,abutments,pillars,posts,struts,buttresses,string or lacing courses.parapet,coping bed blocks,anchor blocks,plain windows sills,fillets etc upto five level,excluding the cost of centering,shuttering and finishing
1121:1.5:3 ( 1 Cement: 1.5coarse sand : 3 graded stone aggregate 20 mm nominal size)
113Banking excavated earth in layer not exceeding 20cm in depth breaking clods watering, rolling each layer with 1/2 tonne roller or wooden or steel rammer and rolling every third and topmost layer with power roller of min. 8 tonne and dressing up in embankments for roads marginal banks , flood banks & guide bank lead upto 50 m. and lift upto 1.5 m.
114SH:- IEI
115Wiring for light/Fan point/Exhaust Fan point/Call bell point with 1.5mm²FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate,suitable G.I.box and earthing the point with 1.5mm²FRPVC insulated copper conductor single core cable etc.as required.
1161) Gr. A
1172) Gr. B
1183) Gr. C
119Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required
120s/f suitable size G.I box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modular switch connection painting etc as reqd.
121(1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as reqd.
1221)2x1.5mm²+1x1.5mm² Earthwire
1232)2x2.5mm²+1x2.5mm² Earthwire
1243)2x4mm²+1x4mm² Earthwire
1255)2x10mm²+1x10mm²Earthwire
1266)2x16mm²+1x16mm²Earthwire
127(1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, phosphatised and power painted including earthing etc. as required (but without MCB/RCCB/isolator)
128(1) 2 + 4way
129(2) Single pole and neutral
130(2) Single pole and neutral
131(1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required.
132(1) 40 Amp
133(2)63 Amp
134(1.84) P/F (following capacity TP&N) dis-connector fuse switch unit inside the exiting cubicle panel board with I.S.I mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd.
135(2) 400 Amp TP&N
136(2) 200 Amp TP & N
137P/F 400Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required.
138S/F Busbar chamber with 4 strips copper busbar of length 600mm suitable for 2oo amps capacity complete with all accessories i/c connection earthing the body as required.
139(8.01) S/F 48” sweep (1200mm)a.c ceiling fan complete with down rod, canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star)
140305mm sweep exhaust fan complete with all accessories connection etc as required
1411.62) S/F stepped type electronic fan regulator on the modular plate switch box i/c connection but excluding modular plate as reqd.
142(1.71) S/F brass batten holder i/c connection etc. as reqd.
143LED white lamp 18w
144S/F 1,5 ton capacity split type air conditioner(Voltas/Hitachi, 3star)
145S/F 25 amp Air conditioner power plug point i/c 4modules metal box on surface or in recess 4 module cover plate and cover in front 25 amp moduler starter 25 amp moduler socket outlet and 25 amp plug i/c connection etc as reqd.
146S/F recess mounting LED down lighter .
147p/f lighting conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. Complete as reqd
148p/f copper tape in horizontal run p/f copper tape 2ommx3mm thick on parapet or surface of wall for lightning conductor as reqd(for horizontal run)
149p/f copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd(for vertical run)
150(3.05) Earthing with copper earth plate 600 mmx 600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as reqd.
151(3.06) Extra for using Salt & Charcoal for copper plate with electrode as reqd.
152Earth connection from earth electrod with 4mm dia in 15mm GI pipe as required
153Fabrication of controlled panel board by 16 guage steels sheet along with componets mounting making strip wiring auxillary components wiring all over the panel i/c fixing charge painting etc as reqd.
154SH:- FIRE FIGHTING
155Fire Hydrant Systems
156External and internal fire hydrant Mild Steel pipe as per IS 1239 Medium & BClasswith all fittings,such asbends,elbows,flanges,tees,unions, coupling,expander/redducers,gaskets,nutboltswashersetc.Make: NEZONE.
157100 MM dia
15880 MM dia
15950 MM dia
16040 MM dia
16135 MM dia
162Providing of Cast iron Butter valve of PN 1.6 rating complete with volt, nuts, compansion flanges. Make: Kartar
163100 MM dia
16480 MM dia
16550 MM dia
166Providing of C.I. Non Return Valves PN 1.6 including washer, nut bolt, 1.5 mm thick compressed asbestos gasket companion flanges Make: LP/Kartar
167100 MM dia
168Supply of MS Structrual Support .
169Supply of Air Release Valve with socket
170Supply of 63 mm dia ISI marked Hydrant valve for Internal/ External landing. MAKE : KDFIRE/ATASEE
171Supply of Double door Glass fronted hose cabinet suitable for Two hoses and one branch pipe nozzle, with lockingarrangement painted red outside and white inside
172Supply of 63 MM dia 15 mtr. long RRL hose pipe with Male & Female Coupling. MAKE : KDFIRE/ATASEE
173Supply of First Aid Swiming hose reel drum with 20MM Thermo plast water hose and nozzle. Make : KDFIRE/ATASEE
174Supplyof63MMShortbranchpipefittedwith25MMNozzle.Make: KDFIRE/ATASEE
175Supply of 25 MM dia Ball valve.
176Supply of sprinkle pendant type
177Supply of Flexible Pipe (1000 m)
178Supply of 2 Way Fire Brigade Inlet
179Supply of Fire Pump Starter
180Supply of Fire Pump : Make Lubi
181Installation Charge.
182Delivery Charge
183FIRE ALARM
184Supply of 12 zone conventional Fire panel. Make : Agni
185Supply of conventional smoke Detector. Make : Agni
186Supply of Manual Call Point. Make : Agni
187Supply of Hooter Sounder. Make : Agni
188Supply of Battery 12 V.
189Supply of 2x1.5 Sq. MM FRLS wire with accessories fittings
190Installation Charges
191FIRE EXTINGUISHER
192Supply of ABC (S/P) Type Fire Extinguisher 4 Kg Capacity, Make : Atasee
193Supply of CO2 Type Fire Extinguisher 2 kg Capacity, Make : Atasee
Disclaimer :