Tender For Special Repair To Bldg No P-42 S&T Area Mes And Pcc Path From Main Road To P-97, P-101 Or Md Accommodation Of 19 Kumaon Ranikhet Under Ge Ranikhet, ranikhet-Uttarakhand

Military Engineer Services-MES has published Tender For Special Repair To Bldg No P-42 S&T Area Mes And Pcc Path From Main Road To P-97, P-101 Or Md Accommodation Of 19 Kumaon Ranikhet Under Ge Ranikhet. Submission Date for this Tender is 02-04-2024. Building Work Tenders in ranikhet Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

42679440
Corrigendum : Tender For Special Repair To Bldg No P-42 S&T Area Mes And Pcc Path From Main Road To P-97, P-101 Or Md Accommodation Of 19 Kumaon Ranikhet Under Ge Ranikhet
Open Tender
Indian
Uttarakhand
ranikhet
02-04-2024

Tender Details

Special Repair To Bldg No P-42 S&T Area Mes And Pcc Path From Main Road To P-97, P-101 Or Md Accommodation Of 19 Kumaon Ranikhet Under Ge Ranikhet

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Mar-2024 CORRIGENDUM NO-01 BOQ 26-03-2024
2 26-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 57100.0 /-
Tender Value
INR 28.54 Lakhs /-

BOQ Items

Name of Work:Special repair to bldg No P-42 S&T area MES and PCC path from main road to P-97, P-101 OR Md accn of19 Kumaon Ranikhet under GE Ranikhet
Sl. No. Item Description
1BOQ (Sch "A") B/R items Demolition of cement concrete unreinforced in ground floors and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed
2M&L for Cement concrete work in pavement/hard-standing of flexural strength 40kg/per square Centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less laid in bays including necessary form work complete all as specified and directed
3M&L for Forming 12 mm thick expansion joints filled with pre-formedbituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ for 100mm thick concrete complete all as specified and directed
4M&L for forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound of Grade-A complete all as specified and directed
5Demolition of Brickwork or stone/boulder or precast PCC block masonary, built-in cement/lime mortar including quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete arches complete all as specified and directed
6Material andlabour for 100mm thick cement concrete (1:4:8) typeD-2 (using 40mm gradedstone aggregates) as in sub base/mass concrete complete all as specified and directed.
7M&L for pre-cast cement concrete block masonry with solid blocks type C1 1:3:6 (using 20mm graded stone aggregate) exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
8Taking down cement or cement limeplaster of any description on brick or PCC block or stone walls or concrete surface, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
9M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
10M&L for preparing new platered or old platered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over a coat of primer complete all as specified and directed.
11Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
12M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes complete all as specified and directed.
13M&L for 10 mm thick rendering in CM 1:4 to vertical surface complete all as specified and directed.
14M & L for non skid ceramic coloured /printedtiles 7 to 8 mm thick (square / rectangular)area of each tiles exceeding 0.06 sqm but not exc 0.11 sqm in floorsetc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles complete all as specified and directed.
15M&L for non - skid coloured /printed ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
16All as per item No 15 above but coloured /printed ceramic tiles 7 to 8 mm thick as in dado /skirting/on vertical surfaces complete all as specified and directed.
17M & L for glazed ceramic coloured / printed tiles 300mm x 450mm x 7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles, complete all as specified and as directed.
18M & L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
19All as per item No 18 but ceramic tiles 7 to 8 mm thick as in dado /skirting /on vertical surfaces complete all as specified and directed.
20M & L for Black Granite (of any type)tiles 20 mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing types in cooking platforms and likecomplete all as specified and directed.
21Demolition of Reinforced cement concreteof any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition complete all as specified and directed .
22M & L for 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in Slabssupportedonwalls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
23M&L for formwork to rough finished surface of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
24M & L for TMT bars 6mm to 8mm dia as in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
25M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement laid in bays including necessary formwork complete all as specified and directed.
26M&L for rendering 15 mm thick on fare faces of brick work or stone masonry or concrete surfaces in cement mortar 1:4 and finished fair and even without using extra cement includigmixing of water proofing compound of approved makecomplete all as specified.(Water Proofing compond shall be measured and paid Separately)
27M & L for 15mm thick rendering in cement mortar 1:6, surface finishedeven & smooth without using extra cement witha dubbing out average 10mm thick on irregular face of walls, complete all as specified and directed.
28M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished smooth and even in ceiling without using extra cement complete all as specified and directed.
29Supply only integral water proofing compound (WPC) complete all as specified and directed.
30M&L for preparing newly plastered wall surfaces andapplying two coat of distemper oil emulsion over a coat of primer(Priming the plastered and other surfacepreparatory to distempering) complete all as specified and directed.
31M&L for complete removal of existingtreatment for preparing old painted surfacess and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed.
32M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
33M&L for Precast1:3:6 type C1 (using 20mm graded stone aggregate) cement concretehollow block masonry exc. 10 cm in width and setting In 1:4 cement mortar complete all as specified and directed.
34M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete all as specified and directed.
35M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
36Taking down chowkats or frames with shutters (without taking off shutters from the frame) areanot exc 1.5 sqm eachcomplete all as specifed & directed.
37All as per item No 36above but area exc. 1.5 sqm and n. exc.4sqm each complete all as specified and directed.
38Taking down and refixing in the same opening chowkats or frames with shutters (without taking off shutters from the frame) area n.exc 1.5 sqm each complete all as specifed & directed.
39Taking down shutters ( per leaf ) of any description exceeding 1.00 sqm each but not exceeding 2 Sqm each complete all as specified and directed.
40M&L for Plain, solid, straight 2nd class hardwood chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, puttogetherwithgluepinned at joints, suppliedandfixed complete all as specified and directed.
41S&F factory made shutters 2nd class HW rail and style 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treat complete all as specified and directed.
42S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., rs, edges of framing plain, chamfered complete all as specified and directed.
43S & F 30 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., edges of framing plain, chamfered complete all as specified and directed.
44S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, in opening as per specification & drawing complete all as specified and directed.
45S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles, & rails with suitable PVC sheet beading, & joined together with solvent cement, in the frame at site as per specification & drawing complete all as specified and directed.
46Supply and fix Continuous (piano) hinges width 30 mmmild steel , bright finish or eletrogalvanised complete all as specified and directed.
47M&L for Pre laminated exterior grade both side laminated board , 19/20 mm thick, grade 1 quality, exterior grade,Commercial type, fixed with screw to timber frame work in cup board shutters/shelves complete all as specified and directed.
48M&L for PCC1:3:6 Type C1 (using 20mm graded stone aggregate) as in hold fasts in masonry walls etc including necessary formwork complete all as specified and directed.
49S & F FI as in clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and directed.
50S & F 100 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
51S & F 200 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
52S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 75mm complete all as specified and directed.
53S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 100mm complete all as specified and directed.
54S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
55S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
56Supply and fix300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
57M & L for Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
58M & L for preparation of newly paintedsteel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
59S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steelwire staplescomplete all as specified and directed.
60S & F inrepairs Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steelwire staplescomplete all as specified and directed.
61Hacking out old broken glass ( any thickness ) size or description from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beadscomplete all as specified and directed.
62S & F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
63M & L forpreparation ofnew wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and directed.
64M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
65Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed.
66S & F MS framed work such as grills, gratings, etc., with end of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
67Cutting chases, forwater tubing or concealed , etc, and making good to facings where required and plastering in cement mortar (1:4)cutting not exceeding 10cm girth in brick walls complete all as specified and directed.
68Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed..
69Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
70S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -I) including all GIfittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
71Refixingof old retrieved 15 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.) complete all as specified and directed.
72S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -I) including all GI fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
73Refixingof old retrieved 20 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc complete all as specified and directed.
74S&F in repairsstop valves/angle valve, cast copper alloy, fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified and directed.
75S&F in repairsstop valves/angle valve concealed type, cast copper alloy, fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified and directed..
76S&F in repairs, 550x400mm vitreous China, wash hand basin white , flat backwith pedestal excluding trap and waste chain and plug and porcelain stopper including sutaible size brackets waste pipe and waste coupling complete all as specified and directed.
77Taking down and refixing Wash basins, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
78S & F in repairs 15 mm bore Fancy type chromium plated Wall Mixer with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges, screwed down high pressure with or without lettered hot and cold screwed for iron pipe complete all as specified and directed. Make i ( Jaquar cat Part No:- FUS- 29281 ii ( Marccat Part No :-MDM - 2350 or Cera Equalant.
79Supply and fixing in repairs15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed..
80Supply & fixing in repairs 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed..
81S & F in repairs bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and directed
82S&F in repairsvitreous china squatting pan, "Orissa" pattern, size 580mm x 440mm, white, with integral foot rests with "P; or "S" trap, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. in reapairs including Provn of lime concrete bedding and making good to floor complete all as specified and directed.
83S&F in repair cast iron Traps 100 mmP or Swith long arm all as specified and directed
84S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of lowor high density of PVC, 32mm diaincluding brackets and connections to pipe complete all as specified and as directed.
85S&F in repairs Prayag hanging system and clamps support and holes with screws and back support rectangular mirror cabinet 400 X 500 (Cat No. 554) and fixed toplug with screws and cup washers complete all as apecified & directed
86S & F in repairs Stainless steel wall mounted plate rack of size 780mm x760mm x 240mm, thickness of sheet not less than 1.0 mm and weight not less than 7.50 kg of approved design/pattern (as approved by Engr-in-charge) with provision for keeping plate and other crockery, fixed with screw and rawl plugs etc on wall complete all as specified and directed.
87M & L for 32mm bore high density polyethylene pipes (HDPE) complete all as specified and directed.
88M&L for 75mm dia PVC floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified and directed.
89S & F in repair 110mm bore PVC (SWR), waste & vent pipe single socketed in any length withrubber ring joints & fixed to wall or in floor complete all as specified and directed.
90S & F 100mm bore PVC (SWR) bends of any radius complete all as specified and directed.
91S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D; type, 60 cm long between flanges complete all as specified and directed.
92S&Fin repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mmcomplete all as specified and directed.
93Taking down and Fixing only sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mmcomplete all as specified and directed.
94S & F 20mm Dia Aluminium alloy anodised curtain rod decorative fency type with brackets complete all as specified and directed.
95S & F PVC connections 15mmdia , 600mm long, , withPTMT nuts& washers at both ends complete all as specified and directed.
96S and F Ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
97S and F in repair Ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
98DismatlingPVC Water tank Exc 250 & n exc 500 ltrand removing from site as specified and directed
99M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
100S & F Rotational moulded PVC water storage tanks 500 Ltrs capcity three layer (cylindrical vertical with closed top) hoissted and fixed in position complete all as specified and directed.
101M&L for preparation of untreated CGI/PGI sheet roof surface of any description not otherwise described over 10 cm width or girth by cleaning , removing dust and incl washing and cleaning etc to receive painting and making good with red lead whereever required and applying two coats of roof paints ( coptic of Jenson & Nicholsan or Antisol of Berger)complete all as spd and directed The contractor shall make necessary arrangement of scaffolding and ensure safety of Labours
102Dismantling plain or corrugated steel sheeting any guage, thickness, including Nainital pattern or similar pattern roof covering complete all as specified and directed.
103S&F 0.63mm thick galvanised corrugated MS sheeting (CGI sheet roofing) with two corrugation side laps,with 120gm Zinc (Spelter) coating per Sqm both sides inclusive fixed with L-type or J-type or cranked hook bolts in lieu of screwscomplete all as specified and directed.
104S&F 0.63mm thick plain galvanised MS sheeting using grade-O sheets with 120gm Zinc (Spelter) coating Per Sqm both sides inclusives, as in roof, ridges, hips, valley gutters, drip and straight flashing complete all as specified and directed.
105Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
106S&F in repair for anodised aluminium snap grid size of grid 605x605mm frame work for false ceilingincluding hangers 2mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed
107Fixing only old retrieved serviceable anodised aluminium snap grid size of grid 605x605mm frame work for false ceilingincluding hangers 2mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
108M & L for4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screwscomplete all as specified and directed.
109M & L for in repair except material for4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screwscomplete all as specified and directed.
110S&Fin repair PVC (SWR) vent cowl 75mm bore complete all as specified and directed.
111S&F in repair gun metal, globe or gate valves, with iron wheel head, screwedboth ends bore dia of pipe 20mm for iron pipe and fixed forcomplete all as specified and directed.
112S&F in repair gun metal, globe or gate valves, with iron wheel head, screwedboth ends bore dia of pipe 15 mm for iron pipe and fixed forcomplete all as specified and directed.
113M&L for sunken floor treatment as described as under(i) to (vi) :- (i) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in anytype of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (ii) M&L to fill the sunken floor with PCC( 1:5:10) type E-2 using bk aggregate over the treated surface completeall as specified and directed. (iii) M& L for 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate mixed with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Vertical sides shall be plastered in CM (1:3) 15 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC& plaster be carried out at the same time completeall as specified and directed. (iv) After laying sewage/ plumbing pipes with fixtures in position2 coats of OMIPLAS EP-101 epoxy compound shall be applied completeall as specified and directed. (v) Spouts of25mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed. (vi) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defects completeall as specified and directed.The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.
114Supplying and laying APP based modified water proofing polymeric membrane, reinforcemed with nonwoven polyester fabric matt (weight not less than 150 gms/sqm) ofminimum 3 mm thick and minimum weighing not less than 3 kg/sqm,laid over bituminous primer on 15mm thick plastered sufaces layer in CM 1:4 with water proofing compound (WPC )@3% by weight on concrete surface roof / parapet, over lap of minimum 75 mm on longitudinal direction and 100 mm on the transverse direction by thermo-fused torchflame application method and top surfaces to be treated with non reflective bituminous aluminium paint @0.15 Kg/Sqm all as per manufacturers instructions as complete all as specified and directed .
115Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
116Removing excavated material (soil) to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed.
117M&L for broken store hardcore of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
118M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling, mass concrete, sub-base & apron etc complete all as specified and directed.
119M&L for chequered cement concrete tiles with grey cement and pigments 300mm x300mm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed.
120Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed.
121Demolition and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortarcomplete all as specified and directed.
122M & L for 150 mm dia Salt Glazed stone ware drain pipes grade A laid in trenches and jointed as specified complete all as specified and directed.
123M & L for PCC 1:3:6 type C2 (using 40 mm gradedstone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed.
124Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soils complete all as specified and directed.
125Removing Excavated soil to a distance exceeding 250 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
126S & F M.S. TMT bars 10mmdia and over as in reinforcment including cut to length,bent in shape required, including cranking bending hooks ends and binding with M.S.wire(annealed) not less then 0.9mm dia complete all specified & directed.
127M&L for Cement concrete 1:2:4 type B-1 (Using 20mm graded stone aggregate) as in haunching and benching for manholes complete all as specified and directed
128M&L for 1:3:6 Type C2 (using 40 mm graded stone aggregate) as in surface channel or drain complete all as specified and directed.
129M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed.
130BOQ (Sch "A") E/M items Taking down carefullyAluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed.
131S & F point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery wall for fixing conduit and plastering the external surfaces and matching the same with existing suface)and sunk cast ironor pressed steel terminal boxes for mounting fittinglike switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size (FRLS)copper conductor cable as in earth wire and connected to common earth dolly complete all as specified and directed.
132All as per item No 131 above but One light point controlled by two Nos of two way switch.
133All as per item No 131 above but One socket outlet 5 pin 5 Amp controlled by one, one way switch on same board.
134All as per item No 131 above but One socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board.
135All as per item No 131 above butwiring with using cable 2.50 sqmm size copper wire (FRLS) and earth wire of PVC insulated (Green colour) 2.50 Sqmm sizecopperwire (FRLS) for one 6 pin socket outlet, 16 Amperes on independent board.
136S&F switch piano flush type single pole, one way 5 Amp complete all as specified and directed.
137S&F switch piano flush type single pole, Two way 6 Amp complete all as specified and directed.
138S&F socket out letmulti 5 pin, 5 Amps, flush type complete all as specified and directed.
139S&F switch piano flush type single pole, one way 15 Amp complete all asspecified and directed.
140S&F socket out let 2 in1,3 pin, 5 and 15 Amp, flush type complete all as specified and directed.
141S&F ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed.
142S & F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed.
143Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed. Note:- The contractor shall submit 5 years warranty of LED tube/bulb alongwith purchase voucher of material.
144Taking down unservicable MCB and S&FMCB SP,240 volts,AC C curve, 10 KA 6 to 32 Amps complete all as specified and directed..
145Taking down unservicable MCB and S&FMCB SPN , 240 volts,AC B curve, 10 KA 40 Amps complete all as specified and directed..
146Taking down unservicable MCB and S&FMCB DP , 240 volts,AC C curve, 10 KA 40 Amps complete all as specified and directed..
147Taking down unserviceable MCB S & FMCB TPN , 415 volts, AC C curve, 10 KA 100Amps complete all as specified and directed..
148Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed . Note:- The contractor shall submit 5 years warranty of LED tube/bulb alongwith purchase voucher of material.
149Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type)single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed .
150S&F sheet metal enclusure for DBs(double door type)Triplepole and neutral 4way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed .
151S & FLED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed. Note:- The contractor shall submit 5 years warranty of LED tube/bulb alongwith purchase voucher of material.
152Taking out old unserviceable Sub main wiring for replacement includingS&F sub main wiring withtwo single core FRLSPVC insulated and sheathed 1100 Volts grade,6 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mmdia with all accessories and one continuous run of4.0 Sqmm copper conductor PVC complete all as specified and directed Note :-Two single core cables along with earth wire and conduit shall be measured as one unit length.
153M&L for earthing complete with galvanised steel,earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
154S & F call bell ding dong AC, 230V single pole fixed over with and including sunk spressed steel box of size 175mmx100mm with 3mm thick plastic laminated backalite shut cover fixed with brass screw complete all as specified and directed,
155S&F bell pushpiano flush type single pole, one way 5 Amp complete all as specified and directed.
156S& F LED Bulb of 9 watt as specified Note:- The contractor shall submit 5 years warranty of LED tube/bulb alongwith purchase voucher of material.
157Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed Note:- The contractor shall submit 5 years warranty of LED tube/bulb alongwith purchase voucher of material.
158Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
159S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps complete all as specified and directed.
160S & F Exhaust fan plastic body heavy duty ISI mark, 250 mm size with louvers including all connecting accessories and cutting opening on wall and making good as per existing surface complete all as specified and directed
161S&F Exhaustfan metallic bady ISI mark, 300 mm size with louvers including cutting openings, through brick/ stone wall , making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accesssories complete all as specified and directed.
162Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
163M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified Note:- The punned thickness of sand shall be measured and paid
164M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the lengrth of brick complete all as specified .
165M & L galvanised steel water tubing "light grade"40 mm bore with all fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed .