Tender For Special Repairs To Bldg No. P-237/1-6 ( Or Md Accn) And Bldg No.T-22 (Or Otm) At Kalimpong Under Ge 867 Ews, kalimpong-West Bengal

Military Engineer Services-MES has published Tender For Special Repairs To Bldg No. P-237/1-6 ( Or Md Accn) And Bldg No.T-22 (Or Otm) At Kalimpong Under Ge 867 Ews. Submission Date for this Tender is 09-04-2024. Building Work Tenders in kalimpong West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42679079
Corrigendum : Tender For Special Repairs To Bldg No. P-237/1-6 ( Or Md Accn) And Bldg No.T-22 (Or Otm) At Kalimpong Under Ge 867 Ews
Open Tender
Indian
West Bengal
kalimpong
09-04-2024

Tender Details

Tender For Special Repairs To Bldg No. P-237 / 1-6 ( Or Md Accn ) And Bldg No.T-22 ( Or Otm ) At Kalimpong Under Ge 867 Ews; 1 Dismantling Of Plain Or Corrugated Steel Sheeting, Any Gauge And Thickness Including Nainital Or Similar Pattern Roof Coverings Complete All As Specified And Directed. 2 S&F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Steel Sheet Of Approved Profile Of Corrugation, 0.50 Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws All As Specified And Directed By Engr-In-Charge. 3 S&F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering, Eaves Board, Ridges, Hips, Valley Gutters, Drip And Straight Flashing Cladding To Wall Etc, Fixed With Self Tapping Screws All As Specified And Directed By Engr-In-Charge. 4 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Complete All As Specified And Directed. 5 S&F Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed. 6 Dismantling Wall And Ceiling Boards ( Fiber, Pulp, Insulation Etc ) Or Insulation Boards / Slabs / Blankets, Any Thickness Including Cover Fillet Complete All As Specified And Directed. 7 Dismantling Timber Fillets, Rails, Posts, Rafters, Purlins, Etc. Under 40 Sq. Cm In Section Complete All As Specified And Directed. 8 S&F False Ceiling With Powder Coated Exposed Gi Grid Suspension System ( E-Grid T-2430 Or Equvalent Load Carrying Capacity With Mid Span Deflection Not Exc. 1 / 360 Span With Hanger Spacing Of 1200Mm C / C ) Consisting Of Main Runner 3600Mm Long, Cross Tee 1200Mm / 600Mm Long And Wall Angle. The Main Runners To Be Placed @ 1200Mm, The Cross Tee 1200Mm Will Be Inserted In The Pre Cut Slots Of Main Runner At A Regular Interval Of 600Mm To Form A Modular Grid Of 1200Mmx600mm. Additional Cross Tees Of 600Mm Shall Be Placed Perpendicular To The Cross Tee 1200Mm Long To Finally Form A Grid Of 600Mmx600mm. Suspensorsystem ( Grid ) Madeout Of Gi Sheet Main Tee Of Size 23.5Mmx38.50Mmx0.36Mm And Cross Tee Of Size 23.5Mmx23.5Mmx0.36Mm And Angle Size 19Mmx19mmx0.36 Mm. Grid Of Modular Size 600Mmx600mm Shall Be Supported By 4 Mm Dia G.I. Wire From Purlins / Soffit With And Including 4Mm Thick High Pressure Steam Cured Non Asbestos Fiber Cement Designer Ceiling Board ( Density>1200Kg / Cum ) Of Size 595Mmx595mm, Confirming Is 14862 & Type B Category Iii Of Iso 8336, Tested As Per As 1530 Part 3 & Bs-476 Part 4, 5, 6, 7 & 8 Complete All As Per ManufacturerS Instruction. ( Make : Everest Or Equvalent As Approved By Ge ) 9 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And Directed. 10 M&L For Machine Cut Kota Stone Slab Flooring 20-25Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Mirror Polishing Complete Including 20 Mm Thick Screed Bed In Cement Mortar ( 1:6 ) Complete All As Specified And Directed. 11 M&L For Machine Cut Kota Stone Slab 20-25Mm Thick In Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete Including 15 Mm Thick Screed Bed In Cement Mortar ( 1:3 ) Complete All As Specified And Directed. 12 M&L For Non Skid Ceramic Coloured Tiles 7 To 8 Mm Thick Premium Quality Conforming To Relevant Is ( Square / Rectangular ) Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqmin Floors Etc Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Surfaces Of Tile Over And Including 20 Mm Thick Screed Bed In Cement Mortar ( 1:6 ) Complete All As Specified And Directed. 13 M&L For Glazed Ceramic Coloured Tiles In Vertical Surface 350X 250X 7 Mm / 450X 350X 7Mm Thick Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Surfaces Of Tile Over And Including 15 Mm Thick Screed Bed In Cement Mortar ( 1:3 ) Complete All As Specified And Directed. 14 Taking Down Cementplaster On Brickor Stone Masonrysurfaces Of Walls Etc Includingrakingout Joints, Hackingfor Key, Scrubbingdown With Wateretc Complete All As Specified And Directed. 15 M&L For 15 Mm Thick Rendering In Cement Mortar ( 1:6 ) On Stone Masonry Surfaces Or Surfaces Other Than Fair Faces Of Brick Work, Rendering Finished Even And Smooth ( Without Using Extra Cement ) Complete Complete All As Specified And Directed. 16 M&L 15 Mm Thick Rendering ( In Two Coats 10Mm+5Mm ) On Fair Faces Of Brick Work Or Concrete Surface In Cement Mortar ( 1:4 ) On External Wall Finished Even And Fair Mixed With Integral Water Proofing Compound @ 3% By Weight Of Cement In 2Nd Coat Or In The Manner Specified By The Manufacturer And In The Proportions Indicated All As Specified And As Directed. Note:-Wpc Will Be Measured And Paid Separately As Supply Only. 17 Supplyonly Integral Water Proofing Compond All As Specified And As Directed. 18 M&Lrendering 5Mm Thick On Fair Faces Of Brick Work Or Concrete Surfacescement Mortar ( 1:3 ) Onconcrete Surface As In Ceiling / Chajja And Rccsurfaces , To Be Finished Even And Smooth ( Without Using Extra Lime Or Cement ) Complete All As Specified. 19 M&L For Preparation Of Existing Surfaces And Applying Two Coat Of Cement Base Paint Complete All As Specfied And Directed. 20 M&L For Preparation Of Newly Plastered Surfaces And Applying Three Coat Of Cement Base Paint Complete All As Specfied And Directed. 21 M&Lpreparation Of Newly Plastered Surfaces Of Wall And Applying Two Coats Of Oil Bound Distemper Over 3Mm Thick Wall Care Putty ( Birla White Or Equivalent ) Complete All As Specified And Directed. 22 M&Lpreparation Of Old Surfaces Of Wall And Applying Two Coats Of Oil Bound Distemper Over 3Mm Thick Wall Care Putty ( Birla White Or Equivalent ) Complete All As Specified And Directed. 23 M&L Preparation Of Old Plastered Surfaces Of Ceiling And Applying Two Coats Of White Wash On Walls Complete All As Specified And Directed. 24 Demolition Of Brick Work Or Stone / Boulder Masonary Buit In Cement Mortar Including All Quions , Arches , Pillars Etc But Excluding Ashler Facing Dressed Stone Work And Precast Concrete And Directed. 25 M&L For Brickwork With Fly Ash Bricks Straight Or Curved On Plan Exc 5 Mtr Mean Radius Built In Cement Mortar ( 1:4 ) Complete All As Specified And Directed. 26 M&L For Brickwork With Fly Ash Bricks Straight Or Curved On Plan Exc 5 Mtr Mean Radius Built In Cement Mortar ( 1:6 ) Complete All As Specified And Directed. 27 M&L For Pcc ( 1:3:6 ) Type C-1 ( Using20 Mm Graded Crushed Stone Aggregate ) As In Bedblocks For Grouting Hold Fasts , Coping, Filling In Pressed Steel Chowkat Or Similarwork Including Necessary Form Work As Required Complete All As Specified And Directed. 28 Demolition Of Reinforced Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided For Including Cutting Of Reinforcement As Required To Facilliate Demolition Complete All As Specified And Directed. 29 M&L For Reinforced Cement Concrete Type B1 ( 1:2:4 ) As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And Directed. 30 Use & Waste Of Formworkto Sides And Soffits Of Shelves Including Sup- Ports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc Complete All As Specified And Directed. 31 S&F Of Tmtbars 10 Mm Dia And Over, Cut To Length , Bent To Shape Required , Including Cranking, Bending Spirally For Hooping For Columns, Hookingends And Binding With Mild Steelwire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips, Complete All As Specified And Directed. 32 S&F Of Tmtbars 6 Mm To 8 Mm Dia, Cut To Length , Bent To Shape Required , Including Cranking, Bending Spirally For Hooping For Columns, Hookingends And Binding With Mild Steelwire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips, Complete All As Specified And Directed. 33 Demolition And Breaking Up Old Broken , Pvc ( Swr ) , Cast Iron, Ac, Swg Soil Waste And Vent Pipe Of 75 / 110 Mm Bore Including Accessories Set In Cement Mortar And Removing Rubbish From Site As Directed By Engineer-In-Charge Complete All As Specified And Directed. 34 S&F Of 110 Mm Pvc ( Swr ) Drain Pipe Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls Complete All As Specified And Directed. 35 S&F Of 75 Mm Pvc ( Swr ) Drain Pipe Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls Complete All As Specified And Directed. 36 S&F Of 110 Mm Bore Pvc ( Swr ) Bend Any Radius With Access Door Complete All As Specified And Directed. 37 S&F Of 75 Mm Bore Pvc ( Swr ) Bend Any Radius With Access Door Complete All As Specified And Directed. 38 S&F Of 110 Mm Bore Pvc ( Swr ) Junction Single ( Single T ) Equal Or Unequal With Access Door Jointing With Solvent Cement Complete All As Specified And Directed. 39 S&F Of 75 Mm Bore Pvc ( Swr ) Junction Single ( Single T ) Equal Or Unequal With Access Door Jointing With Solvent Cement Complete All As Specified And Directed. 40 S&F Of 110 X 75 Mm Bore Pvc ( Swr ) Reducer Including Jointing With Solvent Cement Complete All As Specified And Directed. 41 S&F In Repairs Bevelled Edge Mirror Of Selected Quality Glass, Of Any Size Mounting On 6 Mm Thick Ac Building Board Or Commercial Ply Wood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers, With And Including Aluminium Edging Around Of Mirror Complete All As Specified And Directed 42 S&F In Repairs Brass Chromium Plated Shower Rose With Or Without Swivel Joints 125 Mm Size Including Fixing To Steel Pipe Or Union Complete All As Specified And Directed. 43 S&F In Repair 15 Mm Bore Pvc Connection 450 Mm Long With Two Brass Chromium Plated Brass Nuts And Pvc Washers Complete All As Specified And Directed. 44 S&F In Repairs Angle Stop Valve 15 Mm Bore, Chromium Plated, Fancy Type, With Wall Flange, Screwed Down, High Pressure With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed Complete All As Specified And Directed. 45 S&F In Repairs Sinks Made Of Stainless Steel 1Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar On To Dwarf Wall Or Includingfixing Cantilever Brackets And Connecting Union To Pipe, Overall Size 495Mm X 420Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. 46 S& F Stainless Steel Sink Mixure, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For 15Mm Bore Iron Pipe And Fixed Complete All As Specified And Directed. Make : Jaquar Or Equivalent As Approved By Ge. Make : Jaquar Or Equivalent As Approved By Ge. 47 S&F In Repairs Kitchen Plate Rack Made Out Of Stainless Steel 0.50 Mm Thick Sheet With Partitions And Size Of Rack 800 X 250 X900 Mm With Shape And Pattern As Per Sample Kept In Sample Room Of Ge Officecomplete All As Specified And Directed. 48 S&F In Repair 15 Mm Bore Chromium Plated Bib Tap Fancy Type With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specified And Directed. 49 S& F Brass Cp Basin Mixure, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For 15Mm Bore Iron Pipe And Fixed Complete All As Specified And Directed. Make : Jaquar Or Equivalent As Approved By Ge. 50 S&F Wall Mixer 2 In 1 System-Flr With Provision For Overhead Shower With 115 Mm Long Bend Pipeof Makejaquar Or Equivalent Complete All As Specified And Directed. Make : Jaquar Or Equivalent As Approved By Ge. 51 S&F In Repairsbrass Chromium Plated Tubular Towel Rail Of 20Mm Dia D Type 60Cm Long Between Flanges Complete All As Specified And Directed. 52 S&F In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And Directed. 53 S&F In Repairs Soap Dish, Cp, Fixed To Plugs With Chromium Plated Brass Screws Complete All As Specified And Directed 54 S&F In Repairs Grating Doom 100Mm Dia Complete All As Specified And Directed 55 S&F In Repairs Pvclow Level Flushing Cistern 10 Ltr Capacity, Valveless Syphonic Action Type Complete With Inlet, Ball Valve, Float Valve, Bends Brackets, Rawl Plug, Brass Screws Handle Etc Complete Having Bis Description Mark With Is-2731 With And Including Suitable Size Of Ms Brackets, Plug, Screw All As Required Incl Taking Down Existing High Level / Low Level Flushing Cistern Any Type Disconnecting Pipes And Jointing With New One Etc, And Making Good The Floors / Walls As Per Existing Floor Finish / Wall Finish Including 32 Mm Bore Pvc Flush Pipe And Jointing With Water Closet Of Any Type All As Specified And Directed. 56 S&F In Repairs Water Closet ( Squatt Pattern ) Of Vitreous China Squatting Pan Of Pattern Orrisa Pattern Size 580 X 440 Mm White With Integral Foot Rests ( Excluding Flushing Cistern And Flush Pipe ) Including Connection To Trap And Flushing Pipe Anti Syphonic Pipe Etc Complete Including Trap Set In And Including Necessary Lean Cement Concrete Complete All As Specified And Directed. 57 S&F Vitreous China Wash Basin, Flat Back, Size 450X300mm White, Excluding Taps, Waste, Chain And Plug And Rcelain Stopper But Including Brackets Complete All As Specified And Directed. 58 Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc. And Making Good, Cutting Exceeding 20Cm Girth Complete All As Specified And Directed. 59 Taking Up Or Down 15 Mm Bore Old Steel Tubing And Connections, Including Disconnection Of Fittings From Tubing Including Cleaning For Re-Fixing Or Removal From Site Complete All As Specified And Directed. 60 Taking Up Or Down 20 Mm Bore Old Steel Tubing And Connections, Including Disconnection Of Fittings From Tubing Including Cleaning For Re-Fixing Or Removal From Site Complete All As Specified And Directed. 61 S&F 20Mm Outer Dia Cpvc Pipes Sdr 11 & Plain Cpvc Sdr 11 Fittings On Walls / Ceiling Or Laying In Floors Complete All As Specified. 62 S&F In Repairs 75 Mm Size Pvc ( Swr ) Floor Trap Plain With Grating Including Jointing With Solvent Cement Complete All As Specified And Directed. 63 Taking Down Shutters Of Any Description Exc 1 Sqm And N Exc 2 Sqm Each And Refixing In Same Opening After Resecuring Or Easing & Adjusting Complete All As Specified. 64 Taking Down Chowkhatsor Frame Not Exc 1.50 Sqm Each With Shutter ( Without Taking Off Shutters From The Frame ) Complete All As Specified And Directed. 65 Taking Down Chowkhatsor Frame Exc 1.50 Andnot Exc 4 Sqm Each With Shutter ( Without Taking Off Shutters From The Frame ) Complete All As Specified And Directed. 66 S&F30 Mm Thick ( Batten Thickness ) Second Class Hard Wood, Glazed And Skelton Shutters, Open Rebated And Prepared To Receive Glass, Gauge, Etc , Divided Into Squares, With Plain Chamfered Or Rounded, Mitred And Withoutsash Bars, Edges Of Framing Plain, Chamfered Or Rounded With Cut Mitred Beds For Securing Glass Etc, Supplied And Fitted To Chowkhats Completeall As Specified And Directed. ( Note :- The Dimension Of The Various Components Or Parts Of Shutters Shall Be As Specified In Clause 8.24 ( A ) Of Mes Ssr 2009 Part I ) Complete All As Specified And Directed. 67 S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles A Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Both Side Prelam Pvc Sheet Used Instead Of Plaincolour Pvc Sheet. Stile And Rails Feathered At Edgesbeading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed. 68 S&F Pressed Steel Frames 105 X 60Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete, As Specified, Supplied And Fixed. 69 S&F Pressed Steel Frames 125 X 60Mm For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete, As Specified, Supplied And Fixed. 70 S&Fsteel Window With Side Hung Shutter, Including Box Type Hinges With Steel Handle, And Steel Peg Stay, Complete With Glazing Bars, Dovetailed Or Welded Complete All As Specified. 71 S&Fsteel Window With Side Hung Shutter, Including Box Type Hinges With Steel Handle, And Steel Peg Stay, Complete Without Glazing Bars, Dovetailed Or Welded Complete All As Specified. 72 S&F Steel Ventilator With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete Completeall As Specified And Directed. 73 S&F Steel Window Or Ventilator Fixed Type With Glazing Bar Complete Completeall As Specified And Directed. 74 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And Directed. 75 M&L For 18 / 19Mm Thick Block Boards, Grade 2 Quality, Interior Grade, Commercial Type, Fixed With Screws To Timber Frame-Work Complete All As Specified And Directed. 76 S&F Ist Class Hard Wood External Teak Wood Lipping, 6 Mm Thick On Exposed Surface Of Prelaminated Particle Board Fixed With Nails Complete All As Specified And Directed. 77 M&L For Second Class Hardwood Plain Fillets.Square, Rectangular Or Triangular In Section, Clean Sawn, Secured With Nails Or Screws, Sectional Area Exc 3 Cm And N Exc 6 Sqm Complete All As Specified And Directed. 78 S&F Mild Steel Pressed Handles, 100Mm Oval Type, Stove Enamelled Black Complete All As Specified And Directed. 79 S&F Mild Steel Barrel Tower Bolts 100Mm, Stove Enamelled Black, With Bright Bolt And Fixed Complete All As Specified And Directed. 80 S&F Butt Hinges, Heavy Weight, Cold Rolled Mild Steel, And Fixed Complete All As Specified And Directed. 81 S&F Hasp And Staple, Mild Steel, Wire Type, Stove Enamelled Black, Including Bolt To Hinge Plate And Fixed With Screws Complete All As Specified And Directed. 82 S&F Mild Steel Sliding Door Bolts, Plate Type, Stove Enamelled Black, With Bright Bolt Not Less Than 12Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, Four On Bolt Plate And Two On Staple Plate And Fixed Complete All As Specified And Directed. 83 S&F Butt Hinges, Extruded Aluminium Alloy With Galvanised Mild Steel Hinge Pin, Anodised And Fixed, Type B-21 Complete All As Specified And Directed. 84 S&F Of Continuous ( Piano ) Hinges Mild Steel Bright Finish Or Electro Galvanised 30 Mm Width Of Flaps Complete All As Specified And Directed. 85 S&F Of 150 Mm Long Aluminium, Anodised, Barrel Tower Bolt, Of Extruded Section And Fixed All As Specified And Directed. 86 S&F 150 Mm Size Aluminium Handles, Cast Type, Anodisedand Fixed All As Specified And Directed. 87 S&F Stainless Steel Wire Cloth 0.36Mm Nominal Dia If Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples Complete All As Specified And Directed. 88 S&F In Repair Stainless Steel Wire Cloth 0.36Mm Nominal Dia If Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Wire Staples Complete All As Specified And Directed. 89 Hacking Out Old Broken Glass ( Any Thickness, Size, Qualityor Description ) From Metal Frame Including Punching Or Drilling Out Old Glazing Pins / Spring Clips And Providing And Fixing New Ones Complete All As Specified And Directed. 90 S&F 3 Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Puttyin Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. 91 S&F 4 Mm Thick Figured Glass, Pin Head Type And Glazing With Oil Puttyin Square Not Exc 0.50 Sqm In Each Pane Complete All As Specified And Directed. 92 S&F Mild Steel Framed Work Such As Grills, Grating Etc With End Of Bars Shouldered And / Or Riveted Or Forged Into Spikes, Framed Guard Bars, Barred Iron Doors, Ladders, Framed Balusters, Walk Ways, Railings And Similar Work Confirming To Fe-410-0 Or Fe 310-0 Complete All As Specified And Directed. 93 S&F In Repairs 25Mm Dia Curtain Rod ( Curtain Rails ) , Alumunium Alloy, Powder Coated With And Including Decorative Knobs Etc Complete All As Specified And Directed. 94 M&L Preparation Of New Steel Surfaces Of Any Description Over 10 Cm Width Or Girth Not Otherwise Described And Applying Two Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Complete All As Specified And Directed. 95 M&L Preparation Of Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth Not Otherwise Described And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 96 M&L Preparation Of New Wood Or Wood Based Surfaces Of Any Description Over 10 Cm Width Or Girth Not Otherwise Described And Applying Two Coat Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Specified And Directed. 97 M&L Preparation Of Old Wood Or Wood Based Surfaces Of Any Description Over 10 Cm Width Or Girth Not Otherwise Described And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. 98 Demolition Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc. Laid Bedded And Pointed In Any Mortar Complete All As Specified And Directed. 99 M & L Granite ( Of Any Type ) Work 20Mm Thick ( Table Rubbed And Polished ) In Steps, Jambs, Pillars, Window-Cills, Cooking Platforms And Like In Cement Mortar ( 1:4 ) Including Pointing In White Cement ( 1:2 ) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite Complete All As Specified And Directed By Engr - In - Charge. 100 M & L For Cement Concrete 75Mm In Sub Basetype D-2, ( 1:4:8 ) ( 40Mm Graded Aggregate ) Complete All As Specified And Directed. 101 M&L For 75 Mm Thick Pcc ( 1:3:6 ) Type C-2 Using 40Mm Graded Crushedstone Aggas Inplinth Protection / Path Laid Slope Of 1 In 12 And Finshing Cement Concretesurface Even And Smooth Without Using Extracementwith And Including All Necessary Form Work To Divide The Area In Panels, Finishing Exposed Edges Fair Or Rounding Or Chamfering Of Exposed Edges Or As Directed Byengr -In-Charge. 102 M&L For Dismantling Of Existing Water Closet After Disconnectiing The Flush Pipe, Demolition Of Entire Floor Upto Bottom Of Sunken Portion, Removing Debries Cleaning The Top Of The Rcc Slab In Sunken Portion Incl Peripheral Surfaces And Plastered With 10Mm Thick Cement & Sand Mortar ( 1:3 ) Using Wpc Finished Even And Smooth Without Using Extra Cement Cured Properly And Allowed To Dry And Applying Two Or More Coats Of Epoxy Resin / Polymer Modified Cementatious Coating Like Brush Bond Of Fosroc Or Equivalent Both On Floor And Wall Surfaces Applied As Per Manufacturers Instructions And Plastering The Treated Surfaces ( After Testing ) For Water Tightness ) 15Mm Thick With Cm ( 1:3 ) With Wpc Incl Providing 20Mm Dia Gi Spout With 300 Mm Projection Beyound Outer Face Of Wall Complete All As Specified And Directed. 103 Taking Down Carefully Unserviceable Copper / Aluminium Point Wiring Of Any Description Including All Fittings ( Switch , Socket, Switch Socket Combination, Lamp Holder, Ceiling Rose, Regulator Etc. ) And Making Good Disturbed Surfaces Of Wall, Floor Etc. To Match With Existing Finishes Complete All As Specified And As Directed. 104 Dismantling And Taking Down Unserviceable Main Switches, Dbs Including Sub Main Wiring Etc. Any Type / Size And Making Good Disturbed Surfaces To Match With The Existing Finishes Complete All As Specified And As Directed. 105 Material And Labour For Point Wiring With Two Runs Of Stranded Copper Conductor Pvc Insulatedunsheathed 1.5 Sqmm Frls Cable In And Includingpvc Casing Caping Of Suitable Sizewith Pvc Boards Of Appropriate Sizes And All Requisite Accessories Complete With Pvc Terminals Box For Mounting Switches, Sockets, Fan Regulators Etc With One Single Core Continuous 1.5 Sqmm, Frls Copper Cable For Earth Wire Complete All As Specified And As Directed Forone Light Point Controlled By One Switch. 106 All As Per Item No.105Butone Fan / Exhaust Fan Point Controlled By One Switch Complete All As Specified And As Directed. 107 All As Per Item No.105But One Bell Point Controlled By One Switch Complete All As Specified And As Directed. 108 All As Per Item No.105But One 3 Pin Socket Outlet 5 Amps On The Same Board Complete All As Specified And As Directed. 109 All As Per Item No.105But One 3 Pin Socket Outlet. 5 Amps On The Independent. Board Complete All As Specified And As Directed. 110 All As Per Item No.106But One 15 A Socket Outlet Independent With 2.5 Sq Mm Pvc Cable And 1.5 Sqmm Cable As Earth Continuity Wire Complete All As Specified And As Directed. 111 Point Wiring With 2.5 Sq Mm Pvc Cable And 1.5 Sqmm Cable As Earth Continuity Wire In And Including One Single Pole And Neutral Enclosure Wih Two Pin And Earth Plug And Socket With One Mcb Sp 20 Amps For Geyser. 112 S&F In Repairs Ceiling Rose, 3 Terminal, Pvc / Polycarbonate Insulated Body Complete All As Specified And As Directed. 113 S & F In Repairs Lampangle / Batten Holder Bakelitepin / Retrofittype, In And Including With 10 Watt Led Lamp ( B22 ) Complete All As Specified And As Directed. 114 S&F In Repairs Switch Piano Flush Type Single Pole One Way 5 Amps Complete All As Specifed . 115 S&F In Repairs Bell Push Button5 Amp, Flush Type Complete All As Specified . 116 Supply And Fix Bell, Ding Dong Electric Ac 230 Volts Single Pole Complete All As Specified And As Directed. 117 M & L In Repairs For Switch Socket Combination 3 Pin 5 Amps Flush Type ( Multi Purpose ) Complete All As Specified And As Directed. 118 M & L In Repairs For Switch Socketcombination 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Universal Complete All As Specified And As Directed. 119 S&F In Repairs Led Light Fitting 1X9w Bulkhead Luminaires Including Led Light Driver Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And As Directed. 120 S&F In Repairs Ledtube Lights Fitting, 4 Feet Long 1X 18W, 220V, Ac Decorative Box Type With Holder Including Removable Poly Cabonate Led Tube Light With Inbuilt Driver Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And As Directed. 121 S&F In Repairs Building Led Security Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Including Suitable Size Of Gi Bracke And Clamps For Wall Fixing Complete All As Specified And As Directed. 122 S&F Powerline Vertical Tpn Db With Suitable For 160A Mccb Incomer, Double Door ( Ip-54 ) , 4 Ways, Built- In 250 Amps Copper Busbar For Each Phase, 2 Neutral And 2 Earth Barcomplete Suitable For 415 Volts, Ac, 50 Hz Complete All As Specified And As Directed. Make : Legrand ( Cat No: 507750 ) 123 S&F Sheet Metal Enclosure For Spn Dbs, 8 Ways, Double Door, Built In 200 Amps Bus Bar Complete Suitable For 240 Volts, Ac, 50 Hz Complete All As Specified And As Directed.Make: L&T / Legrand / C&S / Havells 124 Supply And Fix Mccb, 4 Pole, 125 Amps, 415 Volts, 50 Hz, 16Ka Complete All As Specified And Directed By Engr-In-Charge.Make- Legrand, Siemens, Schinder, Havells. 125 S&F In Repairs Mcb, Sp, 240 Volts, Breaking Capacity 10 Ka, Rating 40 To 63 Amps, Complete All As Specified And As Directed.Make: L&T / Legrand / C&S / Havells 126 S&F In Repairs Mcbs, Spn, 240 Volts, Breaking Capacity 10 Ka, Rating 40-63 Amps, Complete All As Specified And As Directed.Make: L&T / Legrand / C&S / Havells 127 S&F In Repairs Mcb, Sp, 240 Volts, Breaking Capacity 10 Ka, Rating 6 To 32 Amps, Complete All As Specified And As Directed.Make: L&T / Legrand / C&S / Havells 128 M&Lsubmain Wiring With Two Single Core Pvc Insulated, Unsheathed, Stranded Copper Conductor Cable ( Frls ) , 1100 Volts Gradeof Size 06 Sqmm ( Nominal Area ) Each And One Single Core 06.0 Sqmm ( Nominal Area ) As Earth Continuity Conductor Drawn Into Pvc Casing Cappingincluding Taking Down Existing Sub Main Wiring Complete All As Specified And Directed.Note: ( I ) Rates For Pvc Casing Capping With Accessories Are Deemed To Be Included In The Unit Rate. 129 Dismantling And Taking Down Of Exhaust Fan From Existing Position And Keep In Safe Cusody, Repainting The Same With Grey Colour Enamal Paint And Refixing The Same After Completion Of All B / R Work. 130 Taking Down Electric Kwh Meterand Keep In Safe Custody And Refixing The Sameas Including Necessary Electric Connection From Main To Kwh Meter And Kwh Meter To Out Going Distribution Board. 131 Taking Down Carefully Electric Storage Type Water Heater ( Geysers ) Of Any Make And Any Capacity From Its Mounting Place Opening For Servicing, Inspection Compete Including Back Plate, Heating Element, Inner Copper Tank Etc, De-Scaling Back Plate And Heating Element By Cleaning With Sulfuric Acid / De-Scaling Compoundpainting Outer Body And Re-Assembling Of Geysers After Repairs Carrying Out And Re-Fixing In Same Position Including Replacement Of Old Nuts, Bolts And Rubber Gasket Etc, Complete All As Specified And As Directed By The Engineer-In Charge.Note :- Any Type Of Rubber Gasket , Rubber Washer, Screws , Insulating Tape Required Shall Be Deemed To Be Included In The Quoted Rate.Store, Complete All As Specified And Directed. Connection Pipe Etc All As Specified. 132 Earthing Complete With Galvanized Mild Steel Earth Plate Electrode Size 600X600x6mm Thick Buried Directly In Ground ( Preferably In Vertical Position ) Earth Pit Not Less Than 2.25 Meter Below Normal Ground Level With Top Edge Of The Earth Plate Not Less 1.5 Meter ( Bgl ) Connected To Galvanized Iron Earth Lead Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nut And Washer Of Galvanized Iron Including Pcc Pit In Rcc 1:2:4 Type B-1, Precast Rcc Cover With Suitable Handle, Excavation And Earth Work In Any Type Of Soil, 20Mm Bore “Medium Grade” Galvanized Iron Water Tubing Fixed With Cast Iron Funnel And Wire Mesh And 15Mm Bore “Light Grade” Galvanized Iron Protection Pipe For Earth Lead Wire Upto 5M Length, Charcoal, Common Salt, Complete All As Shown In Ep No 3 Of Ssr 2009 Part-I, Connected To Test Point Complete, All As Specified And Testing On Completion. 133 Excavation In Trenches / Foundation In Soft / Loose Soil Not Exc. 1.5 Metre Wide And NExc. 1.50M Deep For Lt Under Ground Cable / Pole Foundationand Getting Out Including Forming Bottom Surface To Required Level Or Slope, Complete All As Specified And Directed By Engineer-In- Charge. 134 Returning, Filling In, Including Spreading , Leveling , Watering And Well Ramming In Layer Not Exceeding 25Cm Each Layer Complete All As Specified. 135 Removing Excavated Material Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Pointcomplete All As Specified. 136 Material And Labour For Cable Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armored, Electric Power Cables ( Heavy Duty 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sqmm 3.5 Core, Including Glands, Lugs, Nut, Bolts, Washers As Required At Site, Testing Complete All As Specified And Directed. 137 Material And Labour For Cable Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armored, Electric Power Cables ( Heavy Duty 1100 Volts Grade With Stranded Aluminium Conductor Of Size 16 Sqmm 2 Core, Including Glands, Lugs, Nut, Bolts, Washers As Required At Site, Testing Complete All As Specified And Directed. 138 Sand Cushioning To Underground Cables Provided With A Layer Of Sand 8Cm Thick Before Laying The Cable In Trenches And 15Cm Thick After Laying The Cable In Trenches Complete All As Specified. 139 M&L Sub Class ‘B’Bricks For Covering To Cable Laid Dry Flat , With Width Equal To The Length Of Brick Complete All As Specified And Directed. 140 S & F Steel Pipe Glavanized Lightgrade Of 40 Mm Dia Laid In Trenches Or Under Ground / Floor Or Road Of Fixed With Pole For Protection Of Cable / Earth Sstrip Including Clams With Bolts Nuts And Wasers Complete All As Specifed. 141 Cutting Through Existing Bituminous Road / Pcc / Floor / Approx Size Width 50Cm X 60Cmdepth Along Cross Section Of The Road For Laying Of Gi Tubing / Rcc Pipe For Encasing Of Cable And Repairing The Road To Match With The Original Finish, M&L Complete All As Specified. 142 Note: In Case Doubling / Duplicancy Of Boq Items , The Lowest Quoted Rate Shall Be Applicable For Payment. 143 Schedule Of Credit

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Mar-2024 BOQ CORRIGENDUM BOQ 25-03-2024
2 25-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-04-2024
3 01-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-04-2024
4 06-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 84240.0 /-
Tender Value
INR 42.12 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIRS TO BLDG NO. P-237/1-6 ( OR MD ACCN) AND BLDG NO.T-22 (OR OTM) AT KALIMPONG UNDER GE 867 EWS
Sl. No. Item Description
1Dismantling of plain or corrugated steel sheeting, any gauge and thickness including Nainital or similar pattern roof coverings complete all as specified and directed.
2S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet of approved profile of corrugation, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge.
3S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws all as specified and directed by Engr-in-Charge.
4Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
5S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
6Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
7Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
8S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensorsystem (Grid) madeout of GI sheet main Tee of size 23.5mmx38.50mmX0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8 complete all as per manufacturer"s instruction.(Make : Everest or equvalent as approved by GE)
9Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
10M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
11M&L for Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15 mm thick screed bed in cement mortar (1:3) complete all as specified and directed.
12M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqmin floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
13M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar (1:3) complete all as specified and directed.
14Taking down cementplaster on brickor stone masonrysurfaces of walls etc includingrakingout joints, hackingfor key, scrubbingdown with wateretc complete all as specified and directed.
15M&L for 15 mm thick rendering in cement mortar (1:6) on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement) complete complete all as specified and directed.
16M&L 15 mm thick rendering ( in two coats 10mm+5mm) on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.
17Supplyonly integral water proofing compond all as specified and as directed.
18M&LRendering 5mm thick on fair faces of brick work or concrete surfacescement mortar (1:3)onconcrete surface as in ceiling/chajja and RCCsurfaces , to be finished even and smooth (without using extra lime or cement)complete all as specified.
19M&L for preparation of existing surfaces and applying two coat of cement base paint complete all as specfied and directed.
20M&L for preparation of newly plastered surfaces and applying three coat of cement base paint complete all as specfied and directed.
21M&Lpreparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent) complete all as specified and directed.
22M&Lpreparation of old surfaces of wall and applying two coats of oil bound distemper over 3mm thick wall care putty (Birla white or equivalent) complete all as specified and directed.
23M&L preparation of old plastered surfaces of Ceiling and applying two coats of white wash on walls complete all as specified and directed.
24Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions ,arches ,pillars etc but excluding ashler facing dressed stone work and precast concrete and directed.
25M&L for brickwork with fly ash bricks straight or curved on plan exc 5 mtr mean radius built in cement mortar (1:4) complete all as specified and directed.
26M&L for brickwork with fly ash bricks straight or curved on plan exc 5 mtr mean radius built in cement mortar (1:6) complete all as specified and directed.
27M&L for PCC (1:3:6) type C-1 (using20 mm graded crushed stone aggregate) as in bedblocks for grouting hold fasts , coping, filling in pressed steel chowkat or similarwork including necessary form work as required complete all as specified and directed.
28Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition complete all as specified and directed.
29M&L for reinforced cement concrete type B1 (1:2:4) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
30Use & Waste of formworkto sides and soffits of shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
31S&F of TMTbars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hookingends and binding with mild steelwire (annealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed.
32S&F of TMTbars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hookingends and binding with mild steelwire (annealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed.
33Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site as directed by Engineer-in-Charge complete all as specified and directed.
34S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
35S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
36S&F of 110 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
37S&F of 75 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
38S&F of 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed.
39S&F of 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed.
40S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement complete all as specified and directed.
41S&F in repairs bevelled edge mirror of selected quality glass, of any size mounting on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers, with and including aluminium edging around of mirror complete all as specified and directed
42S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to steel pipe or union complete all as specified and directed.
43S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers complete all as specified and directed.
44S&F in repairs angle stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
45S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
46S& F Stainless Steel Sink mixure,screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaquar or equivalent as approved by GE. Make : Jaquar or equivalent as approved by GE.
47S&F in repairs kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions and size of rack 800 x 250 x900 mm with shape and pattern as per sample kept in Sample room of GE Officecomplete all as specified and directed.
48S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
49S& F Brass CP Basin mixure,screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaquar or equivalent as approved by GE.
50S&F wall mixer 2 in 1 System-FLR with Provision for Overhead shower with 115 mm Long Bend pipeof makeJaquar or equivalent complete all as specified and directed. Make : Jaquar or equivalent as approved by GE.
51S&F in repairsbrass chromium plated tubular towel rail of 20mm dia D" type 60cm long between flanges complete all as specified and directed.
52S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
53S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws complete all as specified and directed
54S&F in repairs Grating doom 100mm dia complete all as specified and directed
55S&F in repairs PVClow level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type all as specified and directed.
56S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete complete all as specified and directed.
57S&F Vitreous China wash basin, flat back, size 450x300mm white, excluding taps, waste, chain and plug and rcelain stopper but including brackets complete all as specified and directed.
58Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
59Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.
60Taking up or down 20 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.
61S&F 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
62S&F in repairs 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
63Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after Resecuring or easing & adjusting complete all as specified.
64Taking down chowkhatsor frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.
65Taking down chowkhatsor frame exc 1.50 andnot exc 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.
66S&F30 mm thick (batten thickness) second class hard wood,glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and withoutsash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats completeall as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I) complete all as specified and directed.
67S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edgesbeading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
68S&F Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
69S&F Pressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
70S&Fsteel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified.
71S&Fsteel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified.
72S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete completeall as specified and directed.
73S&F steel window or ventilator fixed type with glazing bar complete completeall as specified and directed.
74Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
75M&L for 18/19mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and directed.
76S&F Ist Class hard wood external teak wood lipping, 6 mm thick on exposed surface of prelaminated particle board fixed with nails complete all as specified and directed.
77M&L for second class hardwood plain fillets.square,rectangular or triangular in section, clean sawn, secured with nails or screws, sectional area exc 3 cm and n exc 6 sqm complete all as specified and directed.
78S&F Mild steel pressed handles, 100mm oval type, stove enamelled black complete all as specified and directed.
79S&F Mild steel barrel tower bolts 100mm, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
80S&F Butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and directed.
81S&F Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
82S&F Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
83S&F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
84S&F of continuous (piano) hinges mild steel bright finish or electro galvanised 30 mm width of flaps complete all as specified and directed.
85S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed all as specified and directed.
86S&F 150 mm size Aluminium handles, cast type, anodisedand fixed all as specified and directed.
87S&F stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
88S&F in repair stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
89Hacking out old broken glass (any thickness, size, qualityor description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
90S&F 3 mm thick sheet glass ordinary quality and glazing with oil puttyin square not exc 0.50 sqm in each pane complete all as specified and directed.
91S&F 4 mm thick figured glass, pin head type and glazing with oil puttyin square not exc 0.50 sqm in each pane complete all as specified and directed.
92S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-410-0 or Fe 310-0 complete all as specified and directed.
93S&F in repairs 25mm dia curtain rod (curtain rails), alumunium alloy, powder coated with and including decorative knobs etc complete all as specified and directed.
94M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
95M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
96M&L preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
97M&L preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
98Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed.
99M & L Granite (of any type) work 20MM thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr - in - Charge.
100M & L for Cement concrete 75mm in sub basetype D-2, (1:4:8) (40mm graded aggregate) complete all as specified and directed.
101M&L for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded crushedstone aggas inplinth protection/ path laid slope of 1 in 12 and finshing cement concretesurface even and smooth without using extracementwith and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges or as directed byengr -in-charge.
102M&L for dismantling of existing water closet after disconnectiing the flush pipe, demolition of entire floor upto bottom of sunken portion, removing debries cleaning the top of the RCC slab in sunken portion incl peripheral surfaces and plastered with 10mm thick cement & sand mortar (1:3) using WPC finished even and smooth without using extra cement cured properly and allowed to dry and applying two or more coats of epoxy resin/polymer modified cementatious coating like brush bond of Fosroc or equivalent both on floor and wall surfaces applied as per manufacturers instructions and plastering the treated surfaces (after testing)for water tightness) 15mm thick with CM (1:3) with WPC incl providing 20mm dia GI spout with 300 mm projection beyound outer face of wall complete all as specified and directed.
103Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.
104Dismantling and taking down unserviceable main switches, DBs including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.
105Material and labour for point wiring with two runs of stranded copper conductor PVC insulatedunsheathed 1.5 Sqmm FRLS cable in and includingPVC casing caping of suitable sizewith PVC boards of appropriate sizes and all requisite accessories complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed forOne light point controlled by one switch.
106All as per Item No.105butOne fan/ Exhaust fan point controlled by one switch complete all as specified and as directed.
107All as per Item No.105but one bell point controlled by one switch complete all as specified and as directed.
108All as per Item No.105but One 3 pin socket outlet 5 Amps on the same board complete all as specified and as directed.
109All as per Item No.105but One 3 pin socket outlet. 5 Amps on the independent. Board complete all as specified and as directed.
110All as per Item No.106but One 15 A socket outlet independent with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire complete all as specified and as directed.
111Point wiring with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire in and including One single pole and neutral enclosure wih two pin and earth plug and socket with one MCB SP 20 amps for Geyser.
112S&F in repairs ceiling rose, 3 terminal, PVC / Polycarbonate insulated body complete all as specified and as directed.
113S & F in repairs lampangle/batten holder BakelitePin/Retrofittype, in and including with 10 watt LED Lamp (B22) complete all as specified and as directed.
114S&F in repairs switch piano flush type single pole one way 5 Amps complete all as specifed .
115S&F in repairs Bell push button5 Amp, flush type complete all as specified .
116Supply and fix Bell, Ding Dong electric AC 230 Volts single pole complete all as specified and as directed.
117M & L in repairs for switch socket combination 3 pin 5 Amps flush type (multi purpose ) complete all as specified and as directed.
118M & L in repairs for switch socketcombination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and as directed.
119S&F in repairs LED Light fitting 1x9W Bulkhead luminaires including LED light driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
120S&F in repairs LEDtube lights fitting, 4 feet long 1x 18W, 220V, AC decorative box type with holder including Removable poly cabonate LED tube light with inbuilt driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
121S&F in repairs building LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including suitable size of GI bracke and clamps for wall fixing complete all as specified and as directed.
122S&F Powerline Vertical TPN DB with suitable for 160A MCCB incomer, double door (IP-54), 4 Ways, built- in 250 Amps copper busbar for each phase, 2 neutral and 2 earth barcomplete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed. Make : Legrand (Cat No: 507750)
123S&F Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door, built in 200 Amps bus bar complete suitable for 240 Volts, AC, 50 Hz complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
124Supply and fix MCCB,4 pole, 125 Amps, 415 volts, 50 Hz, 16kA complete all as specified and directed by Engr-in-Charge.Make- Legrand, Siemens, Schinder, Havells.
125S&F in repairs MCB, SP,240 volts, breaking capacity 10 KA, rating 40 to 63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
126S&F in repairs MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps,complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
127S&F in repairs MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
128M&Lsubmain wiring with two single core PVC insulated,unsheathed,stranded copper conductor cable (FRLS), 1100 volts gradeof size 06 Sqmm (nominal area) each and one single core 06.0 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing cappingincluding taking down existing sub main wiring complete all as specified and directed. NOTE: (i)Rates for PVC casing capping with accessories are deemed to be included in the unit rate.
129Dismantling and taking down of Exhaust fan from existing position and keep in safe cusody, repainting the same with grey colour enamal paint and refixing the same after completion of all B/R work.
130Taking down Electric KWH meterand keep in safe custody and refixing the sameas including necessary electric connection from main to KWH meter and KWH meter to out going distribution board.
131Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for servicing, inspection compete including back plate, heating element, inner copper tank etc, de-scaling back plate and heating element by cleaning with Sulfuric acid/de-scaling compoundpainting outer body and re-assembling of Geysers after repairs carrying out and re-fixing in same position including replacement of old nuts, bolts and rubber gasket etc, complete all as specified and as directed by the Engineer-in Charge. Note :- Any type of rubber gasket , rubber washer, screws , insulating tape required shall be deemed to be included in the quoted rate.store, complete all as specified and directed. connection pipe etc all as specified.
132Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion.
133Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n"exc. 1.50m deep for LT under ground cable/pole foundationand getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge.
134Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer complete all as specified.
135Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting pointcomplete all as specified.
136Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed.
137Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed.
138Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified.
139M&L Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick complete all as specified and directed.
140S & F Steel pipe glavanized lightgrade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers complete all as specifed.
141Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cmdepth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, M&L complete all as specified.
142Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
143SCHEDULE OF CREDIT
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail