Quotations Through E-Tender Are Invited For Rates Of Items / Materials Annexed As Annexure-1 For Framing Estimate Of Supply, Installation And Commissioning Of Pump Set And Electro Mechanical Works From Reputed Manufacturers / Authorized Dealers, hazaribag-Jharkhand

Drinking Water And Sanitation Department has published Quotations Through E-Tender Are Invited For Rates Of Items / Materials Annexed As Annexure-1 For Framing Estimate Of Supply, Installation And Commissioning Of Pump Set And Electro Mechanical Works From Reputed Manufacturers / Authorized Dealers. Submission Date for this Tender is 09-03-2024. Miscellaneous Fasteners Tenders in hazaribag Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

42641937
Quotations Through E-Tender Are Invited For Rates Of Items / Materials Annexed As Annexure-1 For Framing Estimate Of Supply, Installation And Commissioning Of Pump Set And Electro Mechanical Works From Reputed Manufacturers / Authorized Dealers
Open Tender
Indian
Jharkhand
hazaribag
09-03-2024

Tender Details

Quotations Through E-Tender Are Invited For Rates Of Items / Materials Annexed As Annexure-1 For Framing Estimate Of Supply, Installation And Commissioning Of Pump Set And Electro Mechanical Works From Reputed Manufacturers / Authorized Dealers- Cost Towards Supply, Installation And Commissioning Ofhorizontal Split Case Centrifugal Pump Set Of Make Mather And Platt / Kirlosker / Wpil / Jyotiwithbronze / Ss Impeller , Coupled With Suitable Tefc Squirrel Cage Induction Motor Make Kirloskar / Jyoti / Crompton / Abbmakeand Mounted On A Common Ms Base Plate, Operated On 415 Volt ± 10%, 3 Phase 50 Hz. A.C Supply Having Suitable 1480 Rpm, Along With Suitable Nr Valve - 1 No , Sluice Valve-2 No., Foot Valve- 1 No., Pressure Gauge Etc. All Complete. 2 Capable Of Discharging90000 Gphat A Head Of 45Mtrs 3 Capable Of Discharging27200 Gphat A Head Of 50Mtrs 4 Capable Of Discharging21500 Gphat A Head Of 50 Mtrs 5 Capable Of Discharging14300 Gphat A Head Of 40Mtrs 6 Capable Of Discharging18000 Gphat A Head Of 61Mtrs 7 Capable Of Discharging180 M? / Hrat A Head Of 45 Mtrs 8 Capable Of Discharging38 M? / Hrat A Head Of 32Mtrs 9 Cost Towards Supplying, Installation, Testing And Commissioningof Water Lubricatedvertical Turbine Pump Sets Make Mather & Plate / Kirloskar / Jyoti / Wpil With Heavy Duty M.S Column Assemblycoupled With Vertical Hollow Shaft Sq. Cage Induction Motor Make Kirloskar / Jyoti / Crompton / Abboperated On 415±10% Volts, 50 Hz 1480 Rpm With Sole Plate, Discharge Head, S.S. Socket, Spider Bearing, Sluice Valve-1 No. Nr Valve – 1 No., Pressure Gauge – 1 No. Etc All Complete. 10 Capable Of Discharging 28000 Gph At A Head Of 34Mtrs 11 Capable Of Discharging 90 M? / Hr At A Head Of 81 Mtrs 12 Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt + / -1%, 3 Ph, 50 Hz, With Copper Wound Transformer ( Air / Oil Cooled ) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And UserS Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto / Manual Selector Switch, Raise / Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cables, Earthing With Change Over Switch Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated.1.Over Voltage / Under Voltage, 2.Single Phasing, 3.Cut Off Contactor With Electronic Output Sensing Unit. Servo Controlled Automatic Voltage Stabiliser ( Output 415 + / -1% ) Input 240 To 460 Volt 13 200 Kva Oil Cooled 14 300 Kva Oil Cooled 15 Supplying, Installation, Testing & Commissioning Of Outdoor Type11 / 0.433 Kva Copper Wound Distribution Transformer With Offload Tap Changer 12.5% To 2.5% In Step Of 2.05%, Continuously Rated For Three Phase, 50 Hz, Full Load And Temperature Rise Not Exceeding 45ºc By Thermometer In Oil And 50 ºc By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Of Dy11, Ht Side Connect In Delta & Lt Side Connect In Star With Neutral Brought Out Connected. The Transformer Should Have Power Terminal Bushing Arrangement On Ht Side & Cable Box In Lt Side With Standard Fitting For Mounting Of Transformer With First Filling Of Transformer Oil Including All Accessories Etc. Transformer Shall Be Latest Manufacturing Standerds As Per Amended Is Specification And The Load & No Losses Shall Be Limited To The Values Given Or As Per Is Or Norms Issued By Jseb.All Complete With All Materials. 16 400 Kva Oil Cooled

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Quotations through e-tender are invited for rates of items / materials annexed as Annexure-1 for framing estimate of Supply, Installation and commissioning of Pump set and Electro Mechanical Works from Reputed Manufacturers / authorized dealers
Sl. No. Item Description
1Cost towards Supply, installation and commissioning ofHorizontal split case centrifugal pump set of make Mather and Platt/ Kirlosker/ WPIL/ JyotiwithBronze/ SS Impeller , coupled with suitable TEFC squirrel cage induction motor Make KIRLOSKAR / JYOTI /CROMPTON/ABBmakeand mounted on a common MS base plate, operated on 415 volt ± 10%, 3 phase 50 Hz. A.C supply having suitable 1480 RPM,along with suitable NR Valve - 1 no , sluice Valve-2 no., Foot Valve- 1 no., Pressure Gauge etc. all complete.
2Capable of Discharging90000 GPHat a head of 45Mtrs
3Capable of Discharging27200 GPHat a head of 50Mtrs
4Capable of Discharging21500 GPHat a head of 50 Mtrs
5Capable of Discharging14300 GPHat a head of 40Mtrs
6Capable of Discharging18000 GPHat a head of 61Mtrs
7Capable of Discharging180 m?/hrat a head of 45 Mtrs
8Capable of Discharging38 m?/hrat a head of 32Mtrs
9Cost towards Supplying, Installation, testing and commissioningof water lubricatedvertical turbine pump sets Make Mather & plate/ Kirloskar/ Jyoti/ WPIL with heavy duty M.S column assemblycoupled with vertical hollow shaft sq. cage induction motor make KIRLOSKAR / JYOTI /CROMPTON/ABBoperated on 415±10% volts, 50 Hz 1480 RPM with sole plate, discharge head, S.S. socket, spider bearing, sluice valve-1 no. NR valve – 1 no., pressure gauge – 1 no. etc all complete.
10Capable of Discharging 28000 GPH at a head of 34Mtrs
11Capable of Discharging 90 m?/hr at a head of 81 Mtrs
12Providing, erecting Servo Controlled Automatic Voltage stabiliser suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user"s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cables, earthing with change over switch should be provided. All three phases shall be independently monitored and corrected. Following protections and indications shall be incorporated.1.Over Voltage / Under Voltage,2.Single Phasing,3.Cut off contactor with electronic output sensing unit. Servo Controlled Automatic Voltage Stabiliser (Output 415 +/-1%) Input 240 to 460 Volt
13200 KVA oil cooled
14300 KVA oil cooled
15Supplying, Installation, Testing & commissioning of outdoor type11/0.433 KVA Copper wound Distribution transformer with offload tap changer 12.5% to 2.5% in step of 2.05%, continuously rated for three phase, 50 Hz, full load and temperature rise not exceeding 45ºC by thermometer in oil and 50 ºC by the resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group of DY11, HT side connect in delta & LT side connect in star with neutral brought out connected. The transformer should have power terminal bushing arrangement on HT side & cable box in LT side with standard fitting for mounting of transformer with first filling of transformer oil including all accessories etc. Transformer shall be latest manufacturing standerds as per amended IS specification and the load & NO losses shall be limited to the values given or as per IS or Norms issued by JSEB.all complete with all materials.
16400 KVA oil cooled