Zilla Parishad-ZP has published Construction Of Community Hall At Trihana Tg Block Naxalbari Gp-Upper Bagdogra Mouza-Trihana Tg. Submission Date for this Tender is 14-03-2024. Building Work Tenders in bagdogra West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earthwork in excavation in foundation trenches or drain in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading & stacking the spoil within a lead of 75m … |
2 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
3 | Ordinary cement concrete (mix 4:2:1)with graded stone chips (20mm size) excluding shuttering and reinforcement. If any,(PWD Sch.Item No.22,Page No.35/35,3rd corr.) |
4 | A) Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. a) with earth obtainedfrom excavation of foundation. |
5 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
6 | Brick work with 1st class bricks in cement mortar (1:6) (a) In Superstructure |
7 | 125mm thick work with 1st class bricks in cement morter (1:4) in ground floor. |
8 | Nominal cement concrete (mix 3:1.5:1)with graded stone chips (20mm size) excluding shuttering and reinforcement. If any,i) 1:1.5:3 proportion. |
9 | Reinforcement for R.C.C. works in sll sorts of structures including distridution bars, stirrups, binders etc.including supply of rods, straightening and removal of loose rust, cuttigng to requisite….. |
10 | Hire charges for shuttring with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks……. 25mm to 30mm thick wooden shuttering as per decision and direction of Engineer-In-Charge.. |
11 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shutteringwith staging as per decision & direction of Engineer-In-Charge. which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessar hardwares as per direction of Engineer-in-Charge. In ground floor. |
12 | Plaster to wall, floor etc with sand and cement morter (1:4) including rounding off or amphering corners as directed and racking ….15 mm thick. |
13 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
14 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. (In Ground Floor) |
15 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer"s specification)including cleaning and smoothning of surface.Two Coats.(ii) Internal surface (Ground floor) |
16 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. |
17 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In 1st floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made. (iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak |
18 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
19 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.In G. floor: |
20 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
21 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : With super gloss (hi-gloss) -(i) Two coats (with any shade except white) |
22 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b)On steel or other metal surface :With super gloss (hi-gloss) -i) Two coats (with any shade except white |
23 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm. (a) 40mm X 6mm, 250mm Length |
24 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vii) 75mm. X 40mm. X 1.70mm. |
25 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long. |
26 | Iron socket bolt of approved quality fitted and fixed comp(c)150mm long x 10mm dia bolt. |
27 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete.(iv) 125 mm grip x 10 mm dia rod. |
28 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (asnecessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.(ii) 25 mm. thick |
29 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L.and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size)including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C.manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL) |
30 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).(i) 450 mm X 350 mm |
31 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). Payment for painting will ....be made seperately) (a) For Exposed Work PVC Pipes (a) 15 mm dia. |
32 | (B) 20 mm dia. |
33 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
34 | B) Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint(iii) 630 mm X 450 mm size |
35 | Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
36 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length.(PWD,S&P,P-68,I-23Ab) (ii) 110 mm. Dia. |
37 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.(b) With "S" trap |
38 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
39 | (C ) Supplying, fitting and fixing towel rail with two brackets (a) C.P. over brass (ii) 25 mm dia. and 600 mm long |
40 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline..(A) Above ground |
41 | (B) Under ground |
42 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i)Coloured decorative |
43 | With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.mi) Coloured decorative |
44 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 1000 litre capacity |
45 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1)with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1)to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary,ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm.Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part-I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (i) For 10 users B) With Bazree (N.B Varity) (Other than SAIL/TATA/RINL) |
46 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire(Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl.necy. connections and making earthing attachment and mending good damages to building works. [PVC casingcapping and Switch board both on surface]i) Average run 10 mtr |
47 | i) Average run 9 mtr |
48 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm)single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC.. i) On Board |
49 | ii)Average run 3 mtr |
50 | vi)Step Type Electronics Fan regulator |
51 | iii)Multitune Call Bell (Anchor) |
52 | iv)5 A, piano key type Switch |
53 | v)5 A, 3 pin Piano flush type Socket |
54 | vi)15A flushed type 3 pin Plug Socket |
55 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
56 | Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp… |
57 | Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 30/32 AHavells |
58 | (A) Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl.painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.. |
59 | Supply fittingFixingceiling fanof good quality ISI make…Market Rate (d) 300 mm |
60 | Supply fittingFixingexhaust fanproviding necy for exhaust of following diameter- Havlels make(d) 300 mm |
61 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter (d) 300 mm |
62 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) (d) 300 mm for AL |
63 | Supply of fluorescent light fitting /Tube fittinf Hvals make at the site/work place …. |
64 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener |
65 | Fixing only pendent light fitting complete with lamp, shade and 24/0.2 mm (1.5 sqmm) flexible copper wire incl. S&F pendent holder |
66 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.Havells 40 A |
67 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Havells 2+4 way Enclosure |
68 | Supply & Fixing EI danger board on wall 15 cm x 10 cm (6"x4") |
69 | Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set. |
70 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting |
71 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe |
72 | Supplying & fitting fixing centrigugal motor of 1HP good quality,with all assoceries like starter main switch etc complete |
73 | Deep Tubewell by ODEX-115 method of drilling |
74 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required |
75 | SGST @ 9% |
76 | CGST @9% |
77 | CESS @ 1% |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy