}

Tender For Mcw To Fsd Chalakudy For The Year 2023-24. Sh: Replacement Of Existing A.C.Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing Formg 1 And 2 Godown At Fsd Chalakudy, chalakudy-Kerala

Food Corporation Of India-FCI has published Tender For Mcw To Fsd Chalakudy For The Year 2023-24. Sh: Replacement Of Existing A.C.Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing Formg 1 And 2 Godown At Fsd Chalakudy. Submission Date for this Tender is 21-03-2024. Shed Construction Tenders in chalakudy Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

42589782
Tender For Mcw To Fsd Chalakudy For The Year 2023-24. Sh: Replacement Of Existing A.C.Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing Formg 1 And 2 Godown At Fsd Chalakudy
Open Tender
Indian
Kerala
chalakudy
21-03-2024

Tender Details

Mcw To Fsd Chalakudy For The Year 2023-24. Sh: Replacement Of Existing A.C.Sheet Roofing With Pre-Coated Galvanised Iron Profile Sheet Roofing Formg 1 And 2 Godown At Fsd Chalakudy

Key Value

Document Fees
Refer document
EMD
INR 171610.0 /-
Tender Value
INR 85.80 Lakhs /-

BOQ Items

Name of Work:MCW to FSD Chalakudy for the year 2023-24. SH: Replacement of existing A.C.sheet roofing with pre-coated galvanised iron profile sheet roofing for MG 1 and 2 godown at FSD Chalakudy
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
3Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos sheet
4Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchorblocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the costofcentering,shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)(Zone III) Derived from Natural sources : 4 graded stone aggregate 20 mm nominal size Derived from Natural sources
5Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
6Providing and fixing Green colour pre-coated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
7Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
8Providing and fixing radial exhaust turbo ventillators/extractor capacity of minimum 100cuft per minute air circulated fan of 22" throat dia weight of 5.5kg having throat dia wind ventillator with FRP base plate, including cost of fixing turbo/wind ventillator on new 0.50mm thick pre-coated GI profile sheet roofing on godown roof lincluding the cost of transportation of all materials tools and plants, fixtures & fastenings. Labour, insurance, safety measures etc and as directed by the Engineer in charge including guarantee of turbo ventillators of minimum 03 years and performance warranty etc complete.
9Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
10Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
11Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down guage),finishing with cement mortar 1:3 (1 cement : 3 fine sand as per standard design: In 75X75 mm deep chase
12Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
1318 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mmthick cement plaster 1:6 (1 cement : 6 fine sand).
14Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied1.67 ltr/10 sqm over and including priming coat of exterior primer applied2.20 kg/10 sqm)
15Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated "J" or "L" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified
16Providing and fixing precoated galvanised iron plain profile sheets 0.50 mm (+ 0.05 %), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
17Reparing/Servicing rolling shutters such as removal of top covers tightening/ loosening the springs adjusting the dislocation of parts if any and applying grease to the springs side guides ( 0.40 kg greese/ shutter) after cleaning and refixing the cover in position etc as directed by engineer in charge.
18Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete .
19White washing with lime to give an even shade : Old work (two or more coats)
20Providing 250mm PVC rain water eave gutter with working pressure 4kg/sq cm as per standard design and manufacture with bolts, nut washers etc. including providing necessary spouts/ shoes etc. (Cost of iron clamps, brackets and other fittings will be paid separately)
21Providing flatiron brackets 50x6mm size with necessary bolts, nuts ,washers and welding etc.for fixing PVC eave gutter with purlines
22Providing 250 mm PVC drop having 160mm outletor nearest size as per manufacturers specification to suit the eave gutter etc.complete,
23Providing 160 mm PVC Elbowas per manufacturers specification to suit the drop over theeave gutter etc.complete
24Deduct cost of salvagable materials received from the work of dismantling work on as is where is condition includingremoving from the site - AC sheet
25Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stacking.
26Deduct for Salvage value of dismantled materials of GI J bolts & MS Flats of wind ties as is whereis basis.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail