Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Transit Hostel with Mess, Kitchen & Conference Hall (12 Person Capacity) For Facilities of Higher Officer coming for training from difference State at Dr. Sampurnanand Karagar Prashishan Sanstham (J.T.S.) District-Lucknow |
| 2 | CIVIL WORKS |
| 3 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 4 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 5 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 6 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 7 | Providingandlayinginpositionreadymixedorsitebatcheddesignmix cementconcreteforreinforcedcementconcretework;usingcoarse aggregateandfineaggregatederivedfromnaturalsources,Portland Pozzolana/OrdinaryPortland/PortlandSlagcement,admixturesin recommendedproportionsasperIS:9103toaccelerate/retardsetting ofconcrete,toimprovedurabilityandworkabilitywithoutimpairing strength;includingpumpingofconcretetositeoflaying,curing,carriage forallleads;butexcludingthecostof centering,shuttering,finishingand reinforcementasperdirectionofthe engineer-in-charge,forthefollowing gradesofconcrete. ConcreteofM25gradewithminimumcement contentof330kg/cum |
| 8 | Up to plinth level |
| 9 | PLINTH BAND |
| 10 | R.C.C. WORK IN COLUMN |
| 11 | R.C.C. WORK IN FOOTING |
| 12 | PLINTH BEAM |
| 13 | Providingandlayinginpositionreadymixedorsitebatcheddesignmix cementconcreteforreinforcedcementconcretework;usingcoarse aggregateandfineaggregatederivedfromnaturalsources,Portland Pozzolana/OrdinaryPortland/PortlandSlagcement,admixturesin recommendedproportionsasperIS:9103toaccelerate/retardsetting ofconcrete,toimprovedurabilityandworkabilitywithoutimpairing strength;includingpumpingofconcretetositeoflaying,curing,carriage forallleads;butexcludingthecostof centering,shuttering,finishingand reinforcementasperdirectionofthe engineer-in-charge,forthefollowing gradesofconcrete. ConcreteofM25gradewithminimumcement contentof330kg/cum |
| 14 | Above plinth level |
| 15 | R.C.C. work in Lintel Band |
| 16 | R.C.C. work in slab |
| 17 | R.C.C. work in beams |
| 18 | R.C.C. work in Column |
| 19 | M-150 brick work in one cement & six coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. |
| 20 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 21 | M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:4 cement & coarse sand) |
| 22 | Same as in item above but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 23 | Providing & laying \"brick Coba\" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 25 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 26 | (b) Add extra for Double leaf shutter |
| 27 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) |
| 28 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 29 | Hold fast for chaukhats of doors/windows. |
| 30 | Door / windows & Staircase grill. |
| 31 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 32 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. |
| 33 | Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 34 | Threetrackthreepanelsslidingwindowwithtwoglazed &onewiremeshpanelswithAluminiumchannelforroller track,woolpile,nylonrollerswithSS304body. UsingR3serieswithframe(98mm&above)x (40mm&above)&bothglazedandflyscreen sash(30mm&above)x(55mm&above) withzincalloy(Zamak)powdercoatedhandle oneveryglazedpanelalongwithmulti-point lockingsystem.(Heightupto1.8m). |
| 35 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood. 30 mm thick |
| 36 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 37 | Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading |
| 38 | TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 39 | Fixing of Door, windows/ventilators chaukhats in position. |
| 40 | (a) Door |
| 41 | (b) Windows |
| 42 | (c) Ventilator chaukhats |
| 43 | 15 mm plinth plaster (1 cement :4 coarse sand) including cost of all material, labour T&P etc complete as per direction of engineer-in-charge. |
| 44 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1) 1 cement : 6 coarse sand. |
| 45 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 46 | Addforplasterdripcourse/grooveinplasteredsurfaceormouldingto R.C.C.projections. |
| 47 | 40 mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. |
| 48 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 49 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the approved make & colours) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 50 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 51 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab over 0.50 sqm) |
| 52 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab upto 0.50 sqm) |
| 53 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 54 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 55 | French spirit polishing two or more coats on new works including a coat of wood filler. |
| 56 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 57 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) |
| 58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
| 59 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 60 | Providingandfixingaluminiumslidingdoorbolts,ISImarkedanodised (anodiccoatingnotlessthangradeAC10asperIS:1868),transparent ordyedtorequiredcolourorshade,withnutsandscrewsetc.complete:(a) 250mm x 16mm . |
| 61 | Providingandfixingaluminiumtowerbolts,ISImarked,anodised(anodic coatingnotlessthangradeAC10asperIS:1868)transparentordyed torequiredcolourorshade,withnecessaryscrewsetc.Complete: |
| 62 | (a) 250 mm x 10mm |
| 63 | (a) 200 mm x 10mm |
| 64 | Providingandfixingaluminiumhandles,ISImarked,anodised(anodic coatingnotlessthangradeAC10asperIS:1868)transparentordyed torequiredcolourorshade,with necessaryscrewsetc.complete:(a) 125 mm |
| 65 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 66 | Providingandfixingtiledfalseceilingofspecifiedmaterialsofsize 595x595mmintruehorizontallevel,suspendedoninterlockingmetalgrid ofhotdippedgalvanizedsteelsections(galvanized@120grams/sqm, bothsideinclusive)consistingofmain“T”runnerwithsuitablyspaced jointstogetrequiredlengthandofsize24x38mm madefrom0.30mm thick(minimum)sheet,spacedat1200mmcentertocenterandcross “T”ofsize24x25mmmadeof0.30mmthick(minimum)sheet,1200 mmlongspacedbetweenmain“T”at600mmcentertocentertoform agridof1200x600mmandsecondarycross“T”oflength600mmand size24x25mmmadeof0.30mmthick(minimum)sheettobeinterlocked atmiddleofthe1200x600mmpaneltoformgridsof600x600mmand wallangleofsize24x24x0.3mmand layingfalseceilingtilesofapproved textureinthegridincluding,requiredcutting/making, openingforservices likediffusers,grills,lightfittings,fixtures,smokedetectorsetc. |
| 67 | Main“T” runnerstobesuspendedfromceilingusingGIslottedcleatsofsize27x 37x25x1.6mmfixedtoceilingwith12.5mmdiaand50mmlongdash fasteners,4mmGIadjustablerodswithgalvanisedbutterflylevelclipsof size85x30x0.8mmspacedat1200mmcentertocenteralongmainT, bottomexposedwidthof24mmofallT-sectionsshallbepre-paintedwith polyesterpaint,allcompleteforallheightsasperspecifications,drawings andasdirectedbyEngineer-in-charge. |
| 68 | 12.5mmthicksquareedgePVCLaminatedGypsum Tileofsize595x595mm,madeofGypsumplasterboard, manufacturedfromnaturalgypsumasperIS2095part|and laminatedwithwhite0.16mmthickfireretardantPVCfilm onthefacesideand12micronmetalizedpolyesteronthe backsidewithalledgessealedwiththefacesidePVCfilm whichgoesaroundandwrapstheedgesandisbondedto theedgesandthebacksidemetalizedpolyesterfilmsoasto makethetileacompletelysealedunit. |
| 69 | Providingandfixing wall paneling with WPC wood, DECO Wood Veneer with Melamine Polish as per direcred by the E/c. |
| 70 | Making of drain along with apron (Size 150*150mm) |
| 71 | Supply & filling of cinder in sunken portion of building including braking in to required sizes including supply of all material, T&P required size including of supply of all material , labour, T&P required for proper completion of work. |
| 72 | Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 73 | P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. |
| 74 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 75 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 76 | (b) Suspended floors, roofs, landings, balconies and access platform |
| 77 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 78 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 79 | INTERNAL W/S & SEWERAGE WORK |
| 80 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 81 | Providingandfixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting andmaking good the walls where required : |
| 82 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 83 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge |
| 84 | Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade |
| 85 | Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 86 | Kitchen sink without drain board 510x1040 mm bowl depth 250 mm |
| 87 | Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting Complete Flexible Pipe |
| 88 | 32mm Dia |
| 89 | 40mm Dia |
| 90 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. |
| 91 | Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 92 | Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.(sink & urinal) |
| 93 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 94 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 95 | Providing and fixing toilet paper holder : C.P. brass |
| 96 | Providing and fixing soil, waste, vent pipes Centrifugally cast (spun) iron S&S pipe 100mm dia cast (spun) iron S&S pipe |
| 97 | Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe |
| 98 | Providing and fixing heel rest sanitary bend, in Centrifugally cast (spun) iron pipe S&S 100mm |
| 99 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100X100X100mm |
| 100 | Sand cast iron S&S as per IS : 3989 |
| 101 | Providing and fixingPLAIN JUNCTIONof required degree. 100X100X100mm Sand cast iron S&S as per IS : 3989 |
| 102 | Providing and fixing terminal guard: 100mm Sand cast iron S&S as per IS - 3989 |
| 103 | Providing and fixing collar. 100mm Sand cast iron S&S as per IS - 3989 |
| 104 | Providing and lead caulked joint 100 Dia |
| 105 | Providing and fixingcast iron trap of self cleansing design withcast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989 |
| 106 | Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work. 100mm dia |
| 107 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 108 | Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 109 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall |
| 110 | 15 mm nominal outer dia pipes |
| 111 | 20 mm nominal outer dia pipes |
| 112 | 25 mm nominal outer dia pipes |
| 113 | 32 mm nominal outer dia pipes |
| 114 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall |
| 115 | 15 mm nominal outer dia pipes |
| 116 | 20 mm nominal outer dia pipes |
| 117 | Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work |
| 118 | 25 mm dia, nominal bore |
| 119 | 40 mm dia, nominal bore |
| 120 | 50 mm dia, nominal bore |
| 121 | 65 mm dia, nominal bore |
| 122 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) |
| 123 | 25mm dia, nominal bore |
| 124 | 32 mm dia, nominal bore |
| 125 | 40 mm dia, nominal bore |
| 126 | 50 mm dia, nominal bore |
| 127 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length |
| 128 | 15 mm nominal bore |
| 129 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 130 | 15mm nominal bore |
| 131 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. |
| 132 | 15 mm nominal bore |
| 133 | Providing and fixing PTMT grating of approved quality and colour Circular type |
| 134 | 100 mm nominal dia |
| 135 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 136 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. |
| 137 | Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter |
| 138 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe |
| 139 | Providing and fixing square-mouth S.W. gully trap grade \"A\"’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 100x100 mm size P type With F.P.S. Bricks class designation 75 |
| 140 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 grade Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With F.P.S. bricks with class designation 150 |
| 141 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM |
| 142 | ELECTRIFICATION WORK |
| 143 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 144 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 145 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 146 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 147 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 148 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 149 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 150 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 151 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 152 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 153 | Wiring for group controlled ( looped ) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 154 | Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. |
| 155 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 156 | 20 mm |
| 157 | 25 mm |
| 158 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 159 | 5/6 A switch |
| 160 | 3 pin 5/6 A socket outlet |
| 161 | TV antenna socket outlet |
| 162 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 163 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 164 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 165 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 166 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 167 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 168 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 169 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. (for A.C. Point/MCB Point) |
| 170 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 171 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 172 | 4 way (4 + 12), Double door |
| 173 | 6 way (4 + 18), Double door |
| 174 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 175 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 176 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 177 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB |
| 178 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 179 | Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A |
| 180 | Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 181 | Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A |
| 182 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 183 | 40 A |
| 184 | 63 A |
| 185 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 186 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 187 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 188 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 189 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 190 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 191 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 192 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia |
| 193 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 194 | Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA |
| 195 | Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . |
| 196 | Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. |
| 197 | Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter complete in all respect. |
| 198 | Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light) |
| 199 | Supply and fixing of 55 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA |
| 200 | Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA |
| 201 | Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size |
| 202 | size 25 sq mm x 3-1/2core |
| 203 | size 35 sq mm x 3-1/2core |
| 204 | size 185 sq mm x 3-1/2core |
| 205 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable |
| 206 | size 25 sq mm x 3-1/2core |
| 207 | size 35 sq mm x 3-1/2core |
| 208 | size 185 sq mm x 3-1/2core |
| 209 | Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable |
| 210 | size 16 sq mm |
| 211 | size 25 sq mm |
| 212 | size 35 sq mm |
| 213 | size 95 sq mm |
| 214 | size 185 sq mm |
| 215 | L.T. Switch Panel Board : |
| 216 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. |
| 217 | The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. |
| 218 | The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type |
| 219 | Incoming - |
| 220 | 200 Amp MCCB-1 No. |
| 221 | Outgoing - |
| 222 | 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DB\"s) |
| 223 | 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DB\"s) |
| 224 | 63 Amp 4P MCCB - 1 Nos. (for Terrace pump)) |
| 225 | 40 Amp DP MCB - 2 Nos. (Spare) |
| 226 | (or As per requirment directed by Project Manager.) |
| 227 | Outdoor Fidder Pillar Panel : |
| 228 | Incoming - |
| 229 | 400 Amp MCCB-1 No. |
| 230 | Outgoing - |
| 231 | 200 Amp 4P MCCB - 2 Nos. |
| 232 | 100 Amp 4P MCCB - 1 Nos. |
| 233 | 63 Amp 4P MCCB - 1 Nos. (Spare) |
| 234 | 40 Amp DP MCB - 2 Nos. (Spare) |
| 235 | (or As per requirment directed by Project Manager.) |
| 236 | Miscellaneous Items : |
| 237 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. |
| 238 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 239 | Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. |
| 240 | Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. |
| 241 | Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. |
| 242 | Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. |
| 243 | Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . |
| 244 | FIRE FIGHTING WORK |
| 245 | Supplying, installation, testing & commissioning of manual call box of MS Construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 246 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 247 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in MS box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 248 | Fire Alarm Panel with Talk Back Syetm Arrangements : |
| 249 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. |
| 250 | 10 Zone panel for fire alarm system. |
| 251 | 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) |
| 252 | Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos. talk back unit -1 Set. |
| 253 | Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 Set. |
| 254 | Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No. |
| 255 | Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 Set. |
| 256 | Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH Each sealed maintenance free batteries -1 Set. |
| 257 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 258 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 259 | Fire Pump Set : |
| 260 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump |
| 261 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 262 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. |
| 263 | M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 264 | Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 265 | 450 lpm at 35 m Head |
| 266 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 267 | 80 mm dia |
| 268 | 100 mm dia |
| 269 | Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel |
| 270 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 271 | 80 mm dia |
| 272 | 100 mm dia |
| 273 | Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 274 | 80 mm dia |
| 275 | 100 mm dia |
| 276 | Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 277 | 100 mm dia |
| 278 | Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) |
| 279 | Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m |
| 280 | Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) |
| 281 | Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe |
| 282 | Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 283 | Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. |
| 284 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 285 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 286 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 287 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 288 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 289 | Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. |
| 290 | Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. |
| 291 | Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. |
| 292 | Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :- 100 mm dia |
| 293 | Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. |
| 294 | Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor). 1500x900 mm (Indoor Cabinet) Only Frame |
| 295 | Control Panels (for Terrace Pump) : |
| 296 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -2 Sets |
| 297 | SEPTIC TANK & SOAK PIT |
| 298 | Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. |
| 299 | In all kind of soil upto 1.5m depth |
| 300 | In all kind of soil upto 1.5m to 3.0m. depth |
| 301 | In all kind of soil upto 3.0m to 4.5m. depth |
| 302 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size) |
| 303 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 304 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) including centering and shuttering and reinforcement. |
| 305 | TMT Fe-500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 306 | 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) |
| 307 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 308 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 309 | Providing & fixing 75mm dia vent pipes. |
| 310 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 311 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 312 | M.D. -10- Circular shape 500mm internal diameter |
| 313 | M.D. -2.5- Circular shape 450mm internal diameter |
| 314 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 315 | Centering and shuttering including strutting, propping etc. and removal. |
| 316 | SUBMERSILE PUMP |
| 317 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.(300mm dia) |
| 318 | Upto 90 metre depth below ground level. |
| 319 | Beyond 90 metre & upto 150 metre depth below ground level. |
| 320 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 321 | Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 322 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge. |
| 323 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge. |
| 324 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts if required size complete. 200 mm nominal size dia |
| 325 | Providing and fixing Bail plug /Bottam plug of required dia to the bottam of pipe assembly of tubewell as per IS:2800 (PART-1) 150 mm nominal size dia |
| 326 | Providing and fixing C.I. sluice valve.100 mm nominal bore. Class I |
| 327 | Providing and fixing G.I. pipes complete with G.I. fittings including trenchingand refilling etc.Submerssible to OHT. 80 mm dia nominal bore |
| 328 | Water supply tanker of 5000 litre capacity |
| 329 | Supplyof Submersibule pump with control panel, support wire etc. complete 3.0 H.P. (KSB / EQ.) |
| 330 | Supply and fixing of nylon jali around the slotted pipescomplete as required.Up to 10 meter |
| 331 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sq. mm 3-1/2 core |
| 332 | INTERLOCKING TILES |
| 333 | Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) |
| 334 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. (DSR 4.1.8) |
| 335 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 336 | Providing and laying of 80mm thick interlocking cement concrete tiles (30 Mpa) including levelling and dressing of suface to required level and slope, filling joints with local sand including the cost of labour, Material and T & P etc. required for proper complition of work as directed by Engineer-in-charge. |
| 337 | STORM WATER DRAIN ALONG APRON |
| 338 | Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) |
| 339 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. (DSR 4.1.8) |
| 340 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 341 | 12 mm thick plaster (1:3) coarse sand including cost of all material, labour T&P etc complete as per direction of engineer-in-charge. |
| 342 | 40 mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. |
| 343 | RAIN WATER HARVESTING WORK |
| 344 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 345 | In all kind of soil upto 1.5m depth |
| 346 | In all kind of soil upto 1.5m to 3.0m. depth |
| 347 | In all kind of soil upto 3.0m to 4.5m. depth |
| 348 | In all kind of soil upto 3.0m to 4.5m. depth |
| 349 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 350 | M-150 brick work in 1:4 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 351 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Slab and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 352 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 353 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 Coarse sand |
| 354 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
| 355 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. H.D. -20- Circular shape 560mm internal diameter |
| 356 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole. |
| 357 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 358 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 359 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 360 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 361 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 362 | Constructing brick masonry INSPECTION chamber 60x60x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks 60x60x60 cm inside |
| 363 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 364 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150mm diameter |
| 365 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameterS.W. Pipe |
| 366 | AIR CONDITIONING SYSTEM |
| 367 | Scope of Supply of Air Cooled Type OUTDOOR |
| 368 | The Outdoor / Condensing unit comprising of Variable Speed type Twin Rotrary / Scroll, Single / Multi compressor\"s having minimum of 50% inverter compressor , condenser coil, Variable multi Speed Condenser fan (Propeller / Axial), High / Low pressure switches, Inter connected Refrigerant Pipings etc. |
| 369 | Heating-Cooling VRV System |
| 370 | Actual Capacity - 38 HP (20+18HP) |
| 371 | Scope of Supply of INDOOR UNITS suitable for VRV OUTDOOR Units |
| 372 | DECORATIVE FOUR WAY CASSETTE TYPE ACCESSORIES : |
| 373 | 1.0 Actual Capacity -4.6 TR (Model - FXFSQ140) |
| 374 | 2 Actual Capacity -3.2 TR (Model - FXFSQ100) |
| 375 | 3 Actual Capacity -2.65 TR (Model - FXFSQ80) |
| 376 | DECORATIVE Hi Wall TYPE SPLIT AIR CONDITIONER |
| 377 | Actual Capacity -1.6 TR (Model - FXAQ50ARV16) |
| 378 | Mid SDuctable TYPE with ACCESSORIES : |
| 379 | 1 Actual Capacity -1.65 TR (Model - FXMQ50) |
| 380 | 2 For Low Side |
| 381 | SOLAR BACKUP |
| 382 | Solar Power Plant of Capacity 25 Kw including With Solar Panel, On-Grid Inverter, Module Mounting Structure, Distribution Box, Lighting Arrestor, Earthing, Wires & Connectors Installation & Commissioning (Inc. Civil Work) |
| 383 | GST Extra as applicable |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy