Construction Of District Sports Complex At Palghar,Providing Internal Electrification, External Electrification, Networking, Lifts & Fire Fighting Works For The District Sports Complex At Palghar For District Sports Complex Committee Palghar, palghar-Maharashtra

Department Of Sports And Youth Affairs has published Construction Of District Sports Complex At Palghar,Providing Internal Electrification, External Electrification, Networking, Lifts & Fire Fighting Works For The District Sports Complex At Palghar For District Sports Complex Committee Palghar. Submission Date for this Tender is 14-03-2024. Building Work Tenders in palghar Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42538841
Construction Of District Sports Complex At Palghar,Providing Internal Electrification, External Electrification, Networking, Lifts & Fire Fighting Works For The District Sports Complex At Palghar For District Sports Complex Committee Palghar
Open Tender
Indian
Maharashtra
palghar
14-03-2024

Tender Details

Construction Of District Sports Complex At Palghar, Providing Internal Electrification, External Electrification, Networking, Lifts & Fire Fighting Works For The District Sports Complex At Palghar For District Sports Complex Committee Palghar

Key Value

Document Fees
INR 1359000 /-
EMD
INR 3540.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of District Sports Complex at Palghar,Providing Internal Electrification, External Electrification, Networking, Lifts & Fire Fighting Works for the District Sports Complex at Palghar for District Sports Complex Committee Palghar
Sl. No. Item Description
1S C H E D U L E -" B " CIVIL( PART - A)
2Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 millimetre, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 millimetre in thickness.
3Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 Percent of standard proctor density etc. complete (Material obtained from Other sources)
4Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 metre)
5Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5metre to 3.0metre) By Mechanical Means
6Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
7Providing and laying Cast in situ / Ready Mix cement concrete in Mix 15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)
8Providing and laying in situ M-15 cement concrete of trap / granite / quartzite / gneiss metal with 15% plum of trap stones for foundation and bedding of retaining walls and jetty etc. including necessary formwork, compacting, curing, bailing out water manually in tidal range etc. complete.
9Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.
10Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)
11Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
12Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
13Providing and laying in situ cement concrete M -30 with tremix treatment for 200 millimetre thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregateVertical Shaft Impactor grade finely washed crushed sand) etc. complete
14Providing and laying in situ / Ready Mix cement concreteM-30of trap / granite /quartzite/ gneissmetal for Reinforced Cement Concrete workin foundations like raft, strip foundations, grillage andfootings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
15Providing and laying Cast in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
16(A) Ground Floor
17(B) First Floor
18(C) Second Floor
19Providing and casting in situ cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detaileddesigns and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
20(A) Ground Floor
21(B) First Floor
22(C) Second Floor
23Providing and laying Cast in situ/ Ready Mix cement concrete M-40 post tensioning in PT slabs & PT Beams for the loading as mentioned in relevant drawing as per the technical specifications including decoiling the strands,cutting to the required lenghts, supplying & laying of HT strands(Tata Make),sheating (GI ducts), jointing with couplers & inserting the strands,profiling, fixing live end anchorages including the supply of stressing anchorages, grout vents,making dead end anchorages including flowering the strands,fixing tendon support bars,supervising the fixing of anti-bursting reinforcement, stressing the cable end trimming, grouting the cables with cement slurry mixed with approved admixtures with required tools ,plants,machineries & consumables etc. including demarcationon soffit of the slab with 100 wide red paint indicating cable profiles,including obtaing approval from client/consultant for the work doneof trap/ granite/ quartzite/ gneiss metal for R.C.C. Slabs and Landingsas per detailed designs and drawings includingcentering , formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled Reversible Drum Type mixer/ concrete Batch Mixplant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Including
24(B) First Floor
25Providing and laying Cast in situ / Ready Mix cement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
26(A) Ground Floor
27(B) First Floor
28(C) Second Floor
29Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landingsas per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
30(A) Ground Floor
31(B) First Floor
32(C) Second Floor
33Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
34(A) Ground Floor
35(B) First Floor
36(C) Second Floor
37Providing and laying Cast in situ / Ready Mix cement concrete inM-30 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
38(A) Ground Floor
39(B) First Floor
40(C) Second Floor
41Providing and fixing during laying in Reinforced Cement concrete Slabrectangular 2 millimetre thickMild Steel sheet fan hook box ofsize 180 X 100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface
42(A) Ground Floor
43(B) First Floor
44(C) Second Floor
45Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
46(A) Ground Floor
47(B) First Floor
48(C) Second Floor
49Providing and laying Cast in situ / Ready Mix cement concrete in M20 of trap metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
50Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
51(A) Ground Floor
52(B) First Floor
53(C) Second Floor
54Providing, Supplying & fixing on site GLASS FIBRE REINFORCED POLYMER (GFRP) REBARS in lieu of Thermo Mechanically Treated 500 of various 6 millimetre diameters and of approved make conforming to IRC:137:2022 & IS 18256:2023 as per detailed designs, drawings & schedules and mounted on plastic clips / knotting wire including all material, labour, necessary tools & plants, transportation, stocking / stacking, all leads & lifts, taxes except GST, loading & unloading, cleaning, etc. complete (item to be used only in concrete roads, storm water drains, gutters, plinth level pcc with nominal reinforcement only)
55Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
56(A) Ground Floor
57(B) First Floor
58(C) Second Floor
59Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25milimetre to 450milimetresection as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
60Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricksin Cement Mortor 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
61Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
62(A) Ground Floor
63(B) First Floor
64(C) Second Floor
65Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
66(A) Ground Floor
67(B) First Floor
68(C) Second Floor
69Providing Second class fly ash brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimetre diameter / two hoop iron strips 25 millimetre x 1.60 millimetre at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete.
70Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
71Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
72(A) Ground Floor
73(B) First Floor
74(C) Second Floor
75Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
76(A) Ground Floor
77(B) First Floor
78(C) Second Floor
79Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
80(A) Ground Floor
81(B) First Floor
82(C) Second Floor
83Providing waterproof plaster in Water Closet and bath 20 millimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kilogram per bag of cement of approved make and manufacturer and curing(and filling joints of Nahani trap andany outlet by properly) etc. complete.
84(A) Ground Floor
85(B) First Floor
86(C) Second Floor
87Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
88(A) Ground Floor
89(B) First Floor
90(C) Second Floor
91Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete
92(A) Ground Floor
93(B) First Floor
94(C) Second Floor
95Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
96(A) Ground Floor
97(C) Second Floor
98Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
99(A) Ground Floor
100(B) First Floor
101(C) Second Floor
102Providingandapplying Texture plaster withfinishingwith Purlina / Rustic texture material ( with texture material of Asian / Renava / Nitco / Temtex or equivalent company make ) in 3 to 4 millimeter thickness on previously finished plastered surface including Plaster Groove 6 millimeter thickness or Tape Grooves 35 to 45 millimeter thickness or as required,in all position including preparing the surface scaffolding etc.complete.
103(A) Ground Floor
104(B) First Floor
105(C) Second Floor
106Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortor1:3 line and level including neat finishing scaffolding curing etc. complete.
107(A) Ground Floor
108(C) Second Floor
109Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete.
110Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete.
111(A) Ground Floor
112(C) Second Floor
113Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneatcementfloat,fillingjoints,curingandclearing etc. complete.
114Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete.
115(A) Ground Floor
116(B) First Floor
117(C) Second Floor
118Providing and laying vitrified matt fininsh tileshaving size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring
119(A) Ground Floor
120(B) First Floor
121(C) Second Floor
122Providing and laying in position flooring/Skirting/Dado of Italian Marble of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
123(B) First Floor
124Providing and laying chequered tiles of approved qualityof size 30 centimetre x 30 centimetre for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
125Providing and laying Polished Tandur Stone flooring 25 millimetre to 30 millimetre thick required width in plain/ diamond pattern on a bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
126(A) Ground Floor
127(B) First Floor
128Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 centimetre x 30 centimetre and confirming to Indian Standard 15622-2006 (Group-B HA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
129(A) Ground Floor
130(B) First Floor
131(C) Second Floor
132Providing and laying vitrified matt finish tileshaving size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting
133(A) Ground Floor
134(B) First Floor
135(C) Second Floor
136Providing and laying vitrified mirror / glossy finish tiles having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete.
137(C) Second Floor
138Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 millimetre thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kilogram per square.centimetre reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / millimetre 2, water absorption less than 10 % abrasion / wear resistance less than 2 millimetre ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring.
139(A) Ground Floor
140Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre confirming to corresponding India Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
141(A) Ground Floor
142(B) First Floor
143(C) Second Floor
144Wrestling Matt-Supplying & Fixing Surface that is Approved by World Taekwondo Federation (WTF). Material: XPE, Leather with pattern Technology improvement: Low ratio XPE and dedicated leather with pattern, Absorbing energy, great performance of buffering, excellent breathability, soft surface; compounded by fire, connected by toothed edge, more stable.etc comple and as directed by engineer in charge (Tile size of 1Metre X 1Metre X 50 millimetre, colour options-Red, blue, yellow, green)
145(B) First Floor
146Judo Matt- Supplying & Fixing Surface that is Approved by World Taekwondo Federation (WTF). Material: XPE, Leather with pattern Technology improvement: Low ratio XPE and dedicated leather with pattern compounding to this new Model mat. 8m octagonal competition area is blue, safety area is red. Absorbing energy, great performance of buffering, excellent breathability, soft surface; compounded by fire, connected by toothed edge, more stable. (Tile size of 1Metre X 1Metre X 50 millimetre, colour options-Red, blue, yellow, green)
147(B) First Floor
148Supply and Installation ofhaving thickness of 6 millimetre comprising of 4 millimetre Prefabricated SBR Mat followed by 2 millimetre PU Coatings. Seamless, non-porous and smooth surface for Very good resiliency for comfort, injury prevention, Sustainability through high content of recycled and renewable raw materials in combination with lasting performance through very good mechanical strength, wear resistance and easy maintenance, repair & resurface procedures. System consist ofSBR Matt being laid using two component PU Adhesive followed by Sealer to fill in all the pores of SBR mat,2 coats of PU Resin Layer followed by Top PU Coat and game line marking etc complete and as directed by engineer in charge.
149(B) First Floor
150Providing sills of required material 20 millimetre to 25 millimetre thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete, b) Granite
151(A) Ground Floor
152(B) First Floor
153(C) Second Floor
154Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
155(A) Ground Floor
156(B) First Floor
157(C) Second Floor
158Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
159(A) Ground Floor
160(B) First Floor
161(C) Second Floor
162Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
163(A) Ground Floor
164(B) First Floor
165(C) Second Floor
166Providing and applyingplastic emulsionpaint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface, (excluding the primer coat)etc. complete.
167(A) Ground Floor
168(B) First Floor
169(C) Second Floor
170Providing and applying two coats ofexterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete.
171(A) Ground Floor
172(B) First Floor
173(C) Second Floor
174Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete.
175(A) Ground Floor
176(B) First Floor
177(C) Second Floor
178Providing and applying melamine polish of required finish to the woodwork by spray machine includingknottingand preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete.Note:The work to be executed on prior approval of Superintending Engineer will be necessary.
179(A) Ground Floor
180(B) First Floor
181(C) Second Floor
182Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre X 40 millimetre X 5 millimetre with oil painting, etc. complete
183(A) Ground Floor
184(B) First Floor
185(C) Second Floor
186Providing & Fixing Door Frame out of 12 millimetre & 18 millimetre BWP With Approved Mica Laminates etc. Complete Item
187(A) Ground Floor
188(B) First Floor
189(C) Second Floor
190Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to Indian Standard 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetrelongincludingprimer and oilpainting etc, complete) frame size 60 millimetre x 100 millimetre.
191(A) Ground Floor
192(C) Second Floor
193Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 millimetre thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 millimetre thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete.
194(A) Ground Floor
195(B) First Floor
196(C) Second Floor
197Providing and fixing solid core flush door shutter in double leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
198(A) Ground Floor
199(B) First Floor
200(C) Second Floor
201Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
202(A) Ground Floor
203(B) First Floor
204(C) Second Floor
205Providing and fixing fiber glass reinforced polyster door shutter 35 millimetre thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete.
206(A) Ground Floor
207(B) First Floor
208(C) Second Floor
209Providing and fixing Indian Standard Institute marked double swing flush door shutters conforming to Indian Standard :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimetre thick including Indian Standard Institute marked Stainless Steel L- hinges with necessary screws Fittings and Fixturesper leaf Stainless steel kick plates on both sides of the door of 300 millimetre height Heavy Duty satin finish butt Stainless Steel Hinges (100 millimetre x 75 millimetre x 3 millimetre in size)- 4 numbers Stailess Steel finishedlever handle with mortise lock- 1 no. Floor spring- 1 Number 100 millimetre x 100 millimetre safety glass at the specified location
210(A) Ground Floor
211Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 millimetre with lock plate of 3.15 millimetre thickness reinforced with 35 x 35 x 5 millimetre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 millimetre and 3.15 millimetre respectively with hold fast arrangements, Mild Steel Bracket plate 300 x 300 x 3.15 millimetre minimum size and shape with square bar, suspension shaft of minimum 32 millimetre diameter, hood cover of Mild Steel sheet not less than 0.9 millimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
212Providing and fixing mild Steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc.
213(A) Ground Floor
214(B) First Floor
215(C) Second Floor
216Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 kilogram to 20 kilogram per Squaremetre) Spec.No.: As directed by Engineer- in-charge.
217(A) Ground Floor
218Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 X 38.10 X 0.90 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 X 31.75 X 1.30 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 X 31.75 X 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 X 18 X 1.10 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box
219(A) Ground Floor
220(B) First Floor
221(C) Second Floor
222Providing and fixing in position anodised (as per IS 1868/1982) Aluminium fixed staggered ( Z Type )Ventilator with aluminium rectangular pipe 63 milimetre x 38.10 milimetre x 1.22 milimetre at weight 0.650 Kilogram/Running metre, Aluminium angle of size 15 milimetre x 15 milimetre x 1 milimetre,aluminium channel of 9 milimetre sizes, S.S.mosquito net of 304 Grade,4 milimetre thick float glass per detailed drawing and as directed by Engineer in charge etc.complete.
223(A) Ground Floor
224(B) First Floor
225(C) Second Floor
226Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete.
227(A) Ground Floor
228(B) First Floor
229(C) Second Floor
230Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 millimetre thick clear float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 kilogram per Squaremetre is considered.
231(A) Ground Floor
232Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogram per squaremetre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
233(A) Ground Floor
234(B) First Floor
235(C) Second Floor
236Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards,screwed / fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
237(A) Ground Floor
238(B) First Floor
239(C) Second Floor
240Providng and fixing in position 12 millimetre Plywood Partitions having frame made out of extruded tubular section of size 40 millimetre x 60 millimetre with 12 millimetre thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides,Novateakor equivalent and 5 millimetre thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 millimetre x 12 millimetre and rubber cushioning beading to glass partitions as per approved drawing etc. complete
241(B) First Floor
242METAL FALSE CEILING WITHOUT SUSPENSIONSUPPORT FROM TRUE CEILING: Providing & fixing horizontal level suspended metal ceilings comprising of Metal works F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7 millimetre thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300 millimetre, length ranging from 1500 millimetre to 2660 millimetre. General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7 millimetre as per in IS:513 (1994). Dimensions: The panel Length varies between 1500 millimetre to 2660 millimetre, panel Width shall be 300 millimetre. The dimensional tolerances for length shall be ±1.0 metre up to 1000 millimetre L; ±1.5 millimetre between 1001 to 2000 millimetre L; ±2.0 millimetre between 2001 to 3000 millimetre L. The dimensional tolerances for width shall be ±0.5 metre up to 300 millimetre Width Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3 millimetre (W) x 8 millimetre (H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30 millimetre (H) and shall be bent appropriately bent as per the manufacturer‘s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15 millimetre for rigidity and vertical upturns of 40 millimetre (for length ranging from 1251-2660 millimetre). Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (?e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60° as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µ thickness, having appropriate surface adhesion (or tackiness) corresponding to surface gloss level. Light reflectance: The panel shall have a Light Reflectance of = 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400mm. The difference between the two diagonal dimensions of the panel to be less than 1 millimetre The sag to be measured at the center in accordance with TAIM standards. Access and Plenum space: The panels to be Fully Accessible, with system height of 98 millimetre, and would require a plenum height of a minimum 450 millimetre clear space from bare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15 millimetre, width of around 4? and gap between two planks around 3?. Crates to have layer separators of 1? x 2? dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. Installation Specifications: Primary and secondary runners Installation: U-Profiles, spaced at 1200 millimetre, to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The J- Bars (directional) shall intersect the U-profile at 90° at every module dictated by the panel length. The J-Bar is connected to the U-
243(A) Ground Floor
244(B) First Floor
245(C) Second Floor
246Providing and Fixing ofMineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15 millimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20 millimetre, suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel onXL2 Clip havinga web height of 32 millimetre with 15 millimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7.7 Kgs/M2 and minimum pull out strength of 100 Kgs.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete.
247(C) Second Floor
248Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 millimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 millimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 millimetre s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
249(B) First Floor
250(C) Second Floor
251Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete.
252(B) First Floor
253(C) Second Floor
254Providing and fixing black kadappa stone shelves 25 millimetre thick machine polished, extending the polish upto 20 centimeter width on lowerside, rounding comers, laying in position jointing with bedding cement mortar 1:4 proportion curing etc complete.
255(B) First Floor
256(C) Second Floor
257Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 millimetre diametre and vertical pipe of 38 millimetre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use)
258(A) Ground Floor
259(B) First Floor
260(C) Second Floor
261Providing and fixing 900 millimetre high Stainless Steel 304 Grade Stainless steel railing with 40 millimetre diameter and 1.5 millimetre thick at top,40 millimetre diameter and 1.5 millimetre thick vertical supports spaced at 1.5 metre center to center and 8 millimetre thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
262(C) Second Floor
263ProvidingandFixingProcessedStoneCladdingonwallsurface/plywoodsurface.Reinforce Cement Concrete pardi/WallandalltypeofInterior,Exterior CompoundwallandGateetc.ofcladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures,Colourpigments,Fiberupto thickof230millimetre/25 millimetreincluding scaffolding, fixing of screw, etc. (As directed by Engineer in Charge)
264(A) Ground Floor
265(B) First Floor
266(C) Second Floor
267Providing and applying a Silicon Base Water Repellent Stone Sealers, on Brick / Stone masonry / Concrete surfaces in Two coats by spraying. Including cleaning / sand blasting forremoving dirt / cement mortar patches etc. by force water jet, wire brushing etc. complete.
268(A) Ground Floor
269(B) First Floor
270(C) Second Floor
271Providing and applying Cement Sheet 8 millimetre Thick with all Necessary Fitting & Fasteningetc. complete. (As Directed By Engineer in Charge)
272(C) Second Floor
273Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
274Providing antitermite treatment around the periphery of the existingbuilding as per Indian Standard6313(Part-Hi)by excavating trenches of 20 centimeter width and exposing the sides of columns and plinth beams upto a depth of 300 millimetre and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per Rmt and refilling the trenches etc. complete covering 2 years guarantee on bond paper.
275Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO )
276Providing and fixing valley gutter of 22 Birmingham Wire Gauge (0.8 millimetre) plain galvanised iron sheets 90 centimetre wide with teak wood planking 20 millimetre thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank).
277Providing and fixing Galvanised Iron Pre coated trapezoidal Metallic coloured sheets of 0.50 millimetre thickness (26 Birmingham Wire Gauge) of approved make for roofing without wind ties including fastening with galvanised iron screws and bolts and lead and bitumen washers as per drawing complete. Spec. – As directed by Engineer-in-charge.
278(A) Ground Floor
279(B) First Floor
280(C) Second Floor
281Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded Ultra Voilet protected multicell panels incorporated into a complete system. Co-extruded Ultra Voilet protected polycarbonate panel system of minimum 12 millimetre thick of 900 millimetre (mininum) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on Mild Steel structure (will be paid Separately) with 3 One Numbers self-drilling screws and trapezoid Stainless Steel fasteners holding the base of the standing seam offering best stability having a pull-out load of minimum 7000 Newton (7 Kilo Newton) tested as per ISO 6892:1998 and Indian Standard 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per Indian Standard 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to Ultra Voilet for a minimum of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to Ultra Voilet for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 Watt per metre 2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over Mild Steel structural steel/Mild Steel purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12 millimetre thick panels shall be used for a roofing height of upto 15 metres.
282(C) Second Floor
283Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre X 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rupees 500/- including ponding test etc. complete.
284(A) Ground Floor
285(B) First Floor
286(C) Second Floor
287Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogram per bag of cement laying brick bat coba ofrequired thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years" guarantee on requisite stamp paper including curing etc. complete.
288(B) First Floor
289(C) Second Floor
290Providing and laying in trenches 40millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
291Providing and laying in trenches 50millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
292Providing and fixing on walls/ceiling/floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
293(A) Ground Floor
294(B) First Floor
295Providing and fixing on walls/ceiling/floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
296(A) Ground Floor
297(B) First Floor
298(C) Second Floor
299Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
300(A) Ground Floor
301Providing and fixing on walls/ceiling/floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
302(A) Ground Floor
303(B) First Floor
304(C) Second Floor
305Providing and fixing on walls/ceiling/floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
306(A) Ground Floor
307Providing and fixing on walls/ceiling/floor 50 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
308(A) Ground Floor
309Providing and laying in trenches 15 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
310(A) Ground Floor
311Providing and laying in trenches 20 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
312(A) Ground Floor
313Providing and laying in trenches 25 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
314(A) Ground Floor
315(B) First Floor
316(C) Second Floor
317(D) Terrace Floor
318Providing and laying in trenches 32 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
319(A) Ground Floor
320(B) First Floor
321(C) Second Floor
322(D) Terrace Floor
323Providing and laying in trenches 40 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
324(A) Ground Floor
325(B) First Floor
326(C) Second Floor
327(D) Terrace Floor
328Providing and laying in trenches 50 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
329(A) Ground Floor
330Providing, laying and fixing Poly Vinyl Chloride pipe of 40 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
331(A) Ground Floor
332(B) First Floor
333(C) Second Floor
334Providing, laying and fixing Poly Vinyl Chloride pipe of 50 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
335(A) Ground Floor
336(B) First Floor
337(C) Second Floor
338(D) Terrace Floor
339Providing and fixing 75 millimetre diametre stabiliser pipe/ Poly Vinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
340(A) Ground Floor
341(B) First Floor
342(C) Second Floor
343(D) Terrace Floor
344Providing and fixing 100 millimetre diametre stabiliser pipe/ Poly Vinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
345(A) Ground Floor
346(B) First Floor
347(C) Second Floor
348(D) Terrace Floor
349Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on CEment Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment)
350(A) Ground Floor
351Providing and fixing push cock (Self closing tap) symet type of 15 millimetre diameterincluding necessary socket, testing etc. complete.
352(A) Ground Floor
353(B) First Floor
354(C) Second Floor
355Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55 X 40 centimetre size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including Unplactised Poly Vinyl Chloride waste pipe and trap upto the outside face of the wall, making good the damaged surface,testingetc. complete. (BRAND - HINDWARE/ JOHNSON/ PARRYWARE/ VIENA/ AMERICAN STANDARD)
356(A) Ground Floor
357(B) First Floor
358(C) Second Floor
359Providing and fixing Chromium PlatedTwo way BIB cock of approved make continentalincluding necessary sockets/union nut etc. complete.
360(A) Ground Floor
361(B) First Floor
362(C) Second Floor
363Providing and fixing Chromium Plated wall mixer with provision for overhead shower with 115 millimetre long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete.
364(A) Ground Floor
365(B) First Floor
366(C) Second Floor
367Providing and fixing 10 centimetre Poly Venyl Chloride nahani trap with grating etc. complete.
368(A) Ground Floor
369(B) First Floor
370(C) Second Floor
371Providing and fixing stainless steel sink of size 600 x 510 x 200 millimetre incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
372(A) Ground Floor
373(B) First Floor
374(C) Second Floor
375Providing and fixing Chromium Plated sink cock with raised J" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete."
376(A) Ground Floor
377(B) First Floor
378(C) Second Floor
379Providing and fixing 40 millimetre dia Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
380(A) Ground Floor
381(B) First Floor
382(C) Second Floor
383Providing and fixing European type wall-hung white water closet of Paryware / Hindware with push valve concealed type with cover plate 32 millimetre size of JAQUAR MAKE SERIES FLV-1095 including soilpipe ,vent pipe up to outside face of wall, 100 millimetre diametre Galvanised Iron plug bend inlet pipe all fittings, cutting & making good walls, floors etc. complete.
384(A) Ground Floor
385(B) First Floor
386(C) Second Floor
387Providing and fixing coloured glazed earthenware full stall type Urinal with Poly Vinyl Chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap brackets for fixing the cistern 32 millimetre diametre Poly Vinyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection up to the outside face of the wall.
388(A) Ground Floor
389(B) First Floor
390(C) Second Floor
391Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with Poly Vinyl Chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimetre diametre Poly Vinyl Chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall
392(A) Ground Floor
393(B) First Floor
394(C) Second Floor
395Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one no Stainless Steel 304 hinged rail 76 centimetre and three no Stainless Steel 304 of (Grab Bar) 60 centimetre all including cutting and making good the walls and floors wherever required ,seat cover, cistern and wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge.
396(A) Ground Floor
397Providing and fixing Chromium Plated pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete.
398(A) Ground Floor
399(B) First Floor
400(C) Second Floor
401Providing and fixing Chromium Plated Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
402(A) Ground Floor
403(B) First Floor
404(C) Second Floor
405Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete.
406(A) Ground Floor
407(B) First Floor
408(C) Second Floor
409Providing and fixing 450 millimetre X 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etc. complete.
410(A) Ground Floor
411(B) First Floor
412(C) Second Floor
413Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
414Providing and constructing Brick Masonry Inspection Chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with Reinforced Cement Concrete Cover.
415Providing and fixing 100 millimetre diameter chromium plated brass showers rose to 15millimetre diameter supply pipe including necessary bend and socket complete.
416(A) Ground Floor
417(B) First Floor
418(C) Second Floor
419Providing and fixing H.D.P container Sintex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 200 to 1,000 litres
420(D) Terrace Floor
421Providing and fixing 15 millimetre dia Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
422(A) Ground Floor
423(B) First Floor
424(C) Second Floor
425Providing and fixing Chromium Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.
426(A) Ground Floor
427(B) First Floor
428(C) Second Floor
429Providing and fixing Glass self 125 millimetre wide and 600 millimetre long with necessary chromium plated brackets providing Teak Wood gutties etc. complete
430(A) Ground Floor
431(B) First Floor
432(C) Second Floor
433Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram per Squaremetre of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaning etc. complete, (using 100% crushed sand)
434Providing and laying concrete pipes of Indian standard NP. class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
435Providing and fixing 90 centimetre X 60 centimetre Granite plate engraving 10cm. height letter, figures including painting the lefters / figures with approved colour and shade complete.
436Providing and fixing 45 centimetre wide mild steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diamtre mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder complete. (Anti Corossive Paint)
437Providing and fixing in position Unplasticized Poly Vinol Chloride ultra violet stabilized 110 millimetre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etc. complete
438(D) Terrace Floor
439Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter dia. 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) weldedor clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
440Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthing pits is not considered in this item
441Providing and fixing board displaying information, such as "Name of work, Tender cost, Name of Contractor, Work completion and liability period etc", having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 metre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on Mild Steel angle of size 35 x 35 x 3 millimetre frame with properly cross braced Mild Steel angles of size 35 millimetre x 35 millimetre x 3 millimetre duly painted including Two Mild Steel angle iron posts of size 65 millimetre x 65 millimetre x 6 millimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 centimetre x 60 centimetre x 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge
442Providing and laying in trenches 65 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings.
443Providing and laying in trenches 80 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings.
444Providing and laying in trenches 100 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings.
445Providing and laying in trenches 150 millimetre diametre Ultra Poly Vinyl Chloride pipe including necessary excavation, fittings.
446Providing and constructing Brick Masonry Inspection Chamber 60 centimetre X 45 centimetre With Reinforcement Cement Concrete raft in Black Cotton soil area including cost of reinforcement, 1:2:4 cement concrete channels half round Glazed Stoneware pipes, Brick Masonry, plastering from inside and airtight 75 millimetre thick Reinforcement Cement Concrete cover medium duty 100 kilogram etc. complete.
447Providing and constructing Brick Masonry Inspection Chamber 90 centimetre X 45 centimetre With Reinforcement Cement Concrete raft in Black Cotton soil area including cost of reinforcement, 1:2:4 cement concrete channels half round Glazed Stoneware pipes, Brick Masonry, plastering from inside and airtight 75 millimetre thick Reinforcement Cement Concrete cover medium duty 140 kilogram etc. complete.
448Providing and constructing Ductile Iron circular manhole 45 centimetre diametre at top 90 centimete at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 centimetre thick burnt brick mansonry with 1:1 cement mortar plaster 25 millimetre thick inside and outside 20 millimetre (1:3) ductile iron heavy type cover with ring 125 kilogram in weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer.
449Providing, laying and fixing, jointing Supreme Eco - drain 160 millimetre SN 4 Nu - Drain Unplascticised Poly Vinyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard 15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
450Providing, laying and fixing, jointing Supreme Eco - drain 200 millimetre SN 4 Nu - Drain Unplascticised Poly Vinyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard 15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
451Providing, laying and fixing, jointing Supreme Eco - drain 250 millimetre SN 4 Nu - Drain Unplascticised Poly Vinyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard 15328 & 16098 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
452Providing, laying and fixing, jointing Supreme Eco - drain 315 millimetre SN 4 Nu - Drain Unplascticised Poly Vinyl Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard 15328 & 16098 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.
453Providing and fixing 100millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangements and lock. [Without chamber].
454Recharge Pit : Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre dia of pre-cast reinforce cement concrete rings with 6.5" dia x 25 metre deep borewell at the floor of recharge pit including installation of combination of solid/perforated poly Vinyl Chloride casing pipe wrapped around with netlon mesh including 300millimetre thick sidefilling around outside of Reinforce cement concrete rings (annular space) with 40millimetre size boulders including filling of recharge pit up to 0.5metre depth with 25-75millimetre clean washed gravels from bottom up followed by 0.5metre depth of 10-25millimetre of clean washed stones followed by 0.5metre of washed river fine aggregate (natural sand/crushed sand Vertical Shaft Impactor grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical Shaft Impactor grade finely washed etc.) media layer including covering with Reinforce Cement Concrete slab, manhole frame & cover, poly Vinyl Chloride rungs,poly Vinyl Chloride end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
455Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick-bats.
456Conveying materials obtained from road excavation including all lifts and lead of over 5Kilometre from the site of excavation to the site of deposition as directed.
457Making 150 millimetre diametre Bore in all types of Strata with head core including survey for fixing location of bore transporting of machinery and platform, providing laying fixing casing of 150 millimetre diametre Unplacticised Poly Vinyl Chloride Pipe (CS as per IS:12815) having outer diametre 165 and minimum thickness of 5.70 to 6.50 millimetre diametre along with grouting, checking capacity by flushing test etc. complete.
458Survey for Fixing Location
459Making Bore in all types of Strata
460Providing and Laying and fixing casing of 150 millimetre diametre Ultra Poly Vinyl Chloride pipe to withstand continous internal hydraulic pressure of 6 kilogram per square centimetre (Cross Section as per IS:12818-1992) having outer diametre 165.40 millimetre and minimum thickness 5.70 to 6.50 millimetre along with grouting.
461Checking Capacity by Flushing test
462Supplying and erecting submersible pumpset of required Horse Power with 415 Volt, 50 c/s Alternating Current supply suitable for 150 mm dia. borewell, 3 Horse Power (2 Stage) suitable for 200 to 500 Litre Per Minute discharge at 21 to 11 metre head and (max efficiency at 19 metre head and 300 Iitre per minute) discharge and delievery pipeline 80 millimetre diametre a necessary H. type clamp. As per specification No. WP-SMP
463Supplying and erecting flat flexible 3 core 2.5 square millimetre Poly Vinyl Chloride sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
464Supplying and erecting D.O.L. Starter 400 Volt. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 Horse Power (Similar to L and T make MK-1 DOL Model)
465Providing and laying in situ / Ready Mix cement concreteM-20of trap / granite /quartzite/ gneissmetal for Reinforced Cement Concrete workin foundations like raft, strip foundations, grillage andfootings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
466Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
467Construction of dry lean cement concrete Sub- base over aprepared sub-gradewith coarse and fine aggregate ( natural sand/ Vertical Shaft Impactor grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 millimetre , cement content not to be less than 150 kilogram per Cubic Metre, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved byEngineer-in-charge , compacting withvibratory roller, finishing,curing andincluding preparation of sub-grade surface if required etc. complete.
468Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
469Providing and laying in-situ M30 Grade unreinforced plain cement concretepavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ Vertical Shaft Impactor grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradationas per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcheras per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and gradesas directed by Engineer-in-charge and curingby curing compound /by providing cement vata in cement Mortar 1:8 @0.6metre X 0.6metre centre to centre, admeasuring 80 millimetre at bottom and 40 millimetre at top withdepth of 75millimetre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.
470Providing cast in situ / ready mix M20 grade cement concrete for head walls of Cross Drainage work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer)with Supervisory Control and Data Acquisition
471Providing and fixing in position Thermo Mechanical Treated FE 500,32 millimetre dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 centimetre. Long and at 30.00 centimetre. Centre to Centre and wherever directedincluding handling, straightening, necessary cutting supported by Thermo Mechanical Treated FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.
472Providing, Supplying and fixing on site GLASS FIBRE REINFORCED POLYMER (GFRP) REBARS in lieu of Thermo Mechanically Treated 500 of 16 millimetre diameters and of approved make conforming to Indian Road congress : 137:2022 as per detailed designs, drawings and schedules and mounted on plastic clips / knotting wire including all material, labour, necessary tools and plants, transportation, stocking / stacking, all leads and lifts, taxes except Goods and Service Tax, loading and unloading, cleaning, etc. complete (item to be used only in concrete roads for Dowel Bars)
473Cutting transverse contraction joints 3 to 4 millimetre wide and depth 60 millimetre in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 millimetre wide at top having depth of 15 millimetre as directed by Engineer incharge.
474Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 millimetre to 4 millimetre joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 millimetre deep x 8 millimetre wide)
475Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
476Spreading hard murum/ soft murum/ gravel or kankar for side width complete
477Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.
478Providing expansion joints with 25 millimeter thick bituminous pad as per detailed drawings etc. complete.
479Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450 millimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
480Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECOwith prior approval of concerned Superitending Engineer.
481Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
482Wet Mix Macadam -- Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at Optimum Moisture Content in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver.
483Prime coat - Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including cleaning ofroad surface and spraying, primer at the rate of 0.60 killogram per square metre using mechanical means.
484BITUMINOUS MACADAM :- Providing and laying bituminous macadam using crushed aggregate of Grading 1, premixed with bituminous binder, transported at site with Vessel Traffic Services, laid over a previously prepared surface , finished to the required grade, level, alignment, and rolling to achieve the desired density for 80/100 millimetre compacted thickness with drum mix type hot mix plant with Supervisory Control and Data Acquisition having complying essential features of Hot mix plant as per IRC-27 2009 specified conditions and attachments such as electronic load sensor based belt conveyers,automatic synchronization of bitumen and aggregate fedder,built in dust controller system and Programmable Logic Controller for Drum Mix plant, Sensor paver, and Vibratory roller excluding prime / Tack coat etc. complete --Bitumen Viscosity Grade-30 grade 3.30%
485Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 killogram per 10 square metre Viscosity Grade - 30 bulk bitumen
486BITUMINOUS CONCRETE:- Providing and laying bituminous concrete using crushed aggregates of grading 1, premixed with bituminous binder @ 5.20 per cent by weight of total mix and filler, transported to site with Vessel Traffic Services , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compactionfor 50 millimetre compacted thickness with specified grade of Bitumen,Excluding prime / tack coat. For Bitumen of specified grade -- USING Batch mix type hot mix plant with Supervisory Control and Data Acquisition, Sensor Paver, Vibratory roller with Stone Dust filler. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
487Supply & Installation of IAAF European Track Sandwich system which should have been officially recommended and certified by World Athletics (earlier known as IAAF) Federation to use in all International Athletics Competition. A seamless, water impermeable running track system having base layer with SBR (cast in-situ) that is being entirely adhered to the asphalt base by means of a specially developed polyurethane adhesive and SBR Granules.Consumption rate over dense asphalt are 7.0 killogram per square metre for SBR and 1.45 killogram per square metre of Polyurethane Binder. Priming over asphlat should be at 0.20 killogram per square metre, Polyurethane material for wear layer to be used 2.3 killogram per square metre of polyurethane. Product should be tested and certified as per IAAF & EN-14877 Norms. Track should have a overall thickness of 14.5 millimetre (+/- 4 % max tolerance) with the 11 mm of the Base layer and 3 millimetre of wear layer. Manufacturer should be from Europe (No Asian / Turkey) and his products should have been used for European Championships. Surface average technical standards should include 0.86 Mega Pascal per millimetre Tensile Strength, 77 % Elongation at Break, 41 % Force Reduction at 39.60C, 1.8 millimetre Vertical Deformation at 39.60C, should be Spike resistance, Average friction value of system should be 65. Wear coat to be applied “wet-in-wet” and homogeneous. EPDM granules are to be broadcasted into wet polyurethane wear coat. Supply rate should be 3.6 killogram per square metre. Excess EPDM is to be removed after polyurethane wear coat is cured (this excess quantity is returnable to supplier). EPDM content in wearing surface after removal of excess granules should be 2.8 killogram per square metre net. Physical properties of applied system in compliance with test report. Normal Stress Areas with a minimum thickness of 14.5 millimetre of finished track surface.
488Providing and installing IAAF Approved Field Equipment"s
489DISCUS THROWING CIRCLE -ALUMINIUM (Aluminium Discus Circle made of heavy duty aluminium. This can be folded in 2 parts for easy transportation. IAAF Certified)
490DISCUS THROWING CAGE (Pole vault inlay and cover (Made of heavy duty 92 millimetre Square Steel Tube, HOT GALVANIZED for long life. Poles can be detached from centre for easy transportation and hinged for easy lifting during installation. All poles are bound together with the help of tie bars for sturdiness of the cage. Machine knitted 5 millimetre thick net with square mesh of size 40 millimetre. Net is Ultra Voilet stabilized for long life. Steel tube is used on the top of the net to avoid sagging.Cage with Netting,IAAF Certified)
491HAMMER THROWING CIRCLE - ALUMINIUM (Made of thick Aluminium alloy in angle type construction. Constructed in two halves. Best quality nickel plated hardware used for assembling the unit. Easy to assemble and can be folded very easily for convenient transportation and storage. IAAF Certified )
492DISCUS AND HAMMER THROWING CAGE (Made of heavy duty 100 millimetre Square Steel Tube, HOT GALVANIZED for long life. Poles can be detached from centre for easy transportation and hinged for easy lifting during installation. easy to bind the poles together with the help of tie bars for sturdiness of the cage. Gates are attached to the poles using four hinges and both gates include wheels for easy movement. NET is5 millimetre thick( Machine Knitted )with 40 millimetresquare mesh. Net is Ultra Voilet stabilized for long life. Steel tube is used on the top of the net to avoid sagging. IAAF Certified Cage with Netting)
493SHOT PUT THROWING CIRCLE - ALUMINIUM (Made of thick Aluminium alloy in angle type construction. Constructed in two halves. Best quality nickel plated hardware used for assembling the unit. Easy to assemble and can be folded very easily for convenient transportation & storage.IAAF Certified)
494Take-off Board System (Latest design take-off board system, made of solid wood. Welded aluminium tray protects take-off area and facilitates easy replacements of take-off board and plasticine board. Comes with heavy construction aluminium blanking lid for durability.IAAF Certified )
495Triple Jump Take-off Board System (Stop board made of fibre designed for depressed pad.IAAF Certified)
496Fibre Stop Board - Competition (Stop board made of fibre designed for depressed pad.IAAF Certified)
497Water Barriers (Heavy duty foldable beam made square Pipe inside & covered with thick Water proof solid plywood. Base legs and base made of steel square pipe with spring loaded snap lock system for easy adjustment of three different required heights. 762 millimetre, 838 millimetre, 914 millimetre Legs are fitted into sockets grouted in to the ground. Painted with premium quality Poly urethane paint for longer life and durability. Easy to install & foldable to transport.IAAF Certified)
498Pole Vault Box - Competition (Welded stainless steel construction. Comes with blanking board made of aluminium. Sockets at bottom for drainage of water.IAAF Certified)
499TRACK KERBING (Heavy gauge aluminium features a box profile top. Held in place by 10 millimetre tall ribbed feet. Raised 10 millimetre off the track surface for rapid drainage. Each section of kerbing is milled to allow easy drop in or removal of corresponding sections. Available in Raw or anodized finish. IAAF Certified)
500Providing and erecting chain link fencing 4.57 Metre height with Galvanised Iron chain link of size 50 x 50 millimetre 8 guage thick and fixed 75 millimetre above Ground level on vertical Mild Steel Angle of 40 x 40 x 6 millimetre size including excavating pits for foundation and embedded in Cement concrete block of 1:4:8 mix of size 450 x 450 x 670 millimetre at 1.75 Metre Centre to Centre with iron bar 16 millimetre diametre as hold fast including welding link with angle frame at 30 centimetre centre to centre with nuts and bolts and horizontal Mild Steel Angles at top and bottom of 25 x 25 x 5 millimetre size and vertical Mild Steel flat 35 x 5 millimetre and 25 x 5 millimetre horizontal including cross support of 40 x 40 x 6 millimetre Angles both sides at every comer or bends embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 millimetre including 3 coats of oil painting etc. complete.
501Providing and fixing mild steel grill gate with angle iron frame 65 millimetre x 65 millimetre x 10 millimetre with iron bars at 150 millimetre Center to Centre and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram per Squaremetre.
502Construction of various play courts (i.e. Volley ball, Kho-kho, Kabbade, etc.) as per detailed drawing and direction of Engineer in Charge consisting of various layers i.e. 150 millimetre thick compacted 80millimetre Hand Broken Layer, 75 millimetre thick Hard Murum Layer, 100 millimetre Thick. Singlr Layer of Brick on Edge including filling gaps in sinders of Brick Bats, 50 millimetre thick. compacted mother soil (Including 30 % Black Soil, 40 % Sand, 30 % Garden Soil, including screening in 6 millimetre jali and laying in layer by layer with rolling by light roller), including compacting and curing and even and well levelled surface to be given with wet lime marking and all other relevent details as per above said norms etc. complete
503Providing and fixing Ductile iron manhole cover of light/medium/heavy duty with frame of any size over inspection chamber etc. complete (Prior permission of Superintendent Engineeer is to be obtained before inclusion of this item in the estimate)
504Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipesembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, M.S.Grill gate of 2 Mtrs height with locking arrangement, B.B. masonryhambers for all valves, ventilating shafts, providing and applying three coats of cement paint to the structure
505Providing and supplying ISI standard CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores, unloading etc. complete as directed by Engineer-in-charge. 150 millimetre Diametre CIDF Pipe
506Providing & Supplying ISI mark CIDF Specials for CIDF Pipe
507Providing and Supplying Indian Standard Institute mark CIDFProviding and Supplying Indian Standard Institute mark CIDF sluice valves and butterfly valves of following diameterncluding all central and local taxes,octroi, inspectiion charges railway freight unloading from railway wagons, loading into trucks and transportation to departmental store stacking etc. complete (Sluice valve as per IS 780 & 2906 -1994 & Butter fly valves as per IS 13095 -1991)150 millimetre diametre Sluice valve Providing and Supplying Indian Standard Institute mark CIDF sluice valves and butterfly valves of following diameter including all central and local taxes, octroi, inspectiion charges railway freight unloading from railway wagons, loading into trucks and transportation to fepartmental store stacking etc. complete (Sluice valve as per Indian Standard 780 & 2906 -1994 & Butter fly valves as per IS 13095 -1991), 150 millimetre diametre Sluice valve.
508Making cross connection to existing distribution main of any type including excavation, breaking and removing exiting pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line (the number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will beupplied free of cost at stores). For 150 millimetre Diametre Pipe.
509S C H E D U L E -" B "(PART - B)
510Laboratory Testing Charges
511Cement
512St. Consistancy, Fineness. Sp. Gravity, Setting Time, Comp. Strength, Soundness
513Natural Sand
514Moisture Content
515Fineness Modulus
516Silt Factor
517Steel
518Tensile Strength, % Elongation, Yeild Stress, Wt. per Rmt, Bend/Rebend Test, Proof Stress
519Cr. Metal/Washed Sand
520Sieve Analysis
521Specific Gravity, Water Absorption, Crushing Value, Impact Value
522Abrasion Value
523Flakiness Value & Elongation Index
524Bricks
525Water Absorption, Comp. Strength, Efflorescence
526Murum
527Sieve Analysis
528Gradation
529Plasticity Index
530Rubble
531Crushing Value, Comp. Strength, Water Absorption, Specific Gravity
532M20 Cement Concrete
533Comp. St. of Cube
534Conc. Mix. Design
535Ceramic Tiles
536Water Absorption,Modulus of Rupture
537Vetrified Tiles
538Water Absorption,Modulus of Rupture
539Flooring of Natural Stones (Kota, Granite, Tandur, Rough Shahabad)
540Water Absorption,Specific Gravity
541AlluminiumSection
542Thickness, Mass per Rmt
543Asphalt
544Penetration, Specific Gravity, Softening Point, Flash & Fire Point
545Ductility
546Viscosity
547Extraction Test for OGC
548Royalty Charges
549FOR NATURAL SAND
550FOR OTHER MATERIALS
551S C H E D U L E -" B " ELECTRICAL( PART - A)
552HT SUBSTATION Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz.,100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40? by thermometer in oil and 45? by the resistance method in winding at full load rating, using type A winding insulation (Kraft paper) , with standard accessories complete with test certificate with losses below 475 Watts at 50%load, 1650 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
553Supplying & erecting inline D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200Amps as incomer & 6 Nos. 100 Amps KitKat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set &L.A. Set. 2 Nos. of Top channel of size 100 mmx 50 mm for erection of A.B.Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Beltetc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. Vcross arm, top clip, insulators etc. complete with caution board & barbed wire,D.P. Structure shall be erected in c.c. foundation complete
554Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 200 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.
555Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
556Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
557Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle ofthefencing frame and the otherside inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
558Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
559CAPTIVE POWER Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 0.25 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
560Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
561Supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply,a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 17.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
562Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 82.5 kVA up to 100 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
563Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
564Making cement concrete foundationin 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
565LT PANELS Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
566Supplying, erecting, testing & commisioning bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm ( width) X 5 mm (thickness), with 99.9 % aluminium purity as per E91E grade & currentdensity 0.8 A per sq mm compliance to IS 5082 and enclosure fabricated with 16SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating and two nos of separateearthing terminals complete as per specification no. CP-BB
567Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
568Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V, aux.supply 90-300 V AC/DC, flush mounted (96 x 96 mm) meter constant Whviewing in LCD multifunction meters in auto scroll mode with voltage, current, frequency, power factor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
569Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
570Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
571Supplying & erecting LED type indicating pilot lamp with LED colour blue,230 / 250 V on provided box / panel with necessary material, wiring &connections etc.
572Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for three phase and neutral with compliance to IEC 61643-11 asper specification no. CP-SPD
573Supplying and erecting 30 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
574Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.
575Supplying and erecting triple pole mini feeder pillar with 500V, 300A FP MCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet boxwith supporting angles, self locks, gasket having IP54,IK10 protection and slantingtop to be erected on provided foundation as per specification no. SW-SWR/MFP
576Supplying and erecting triple pole mini feeder pillar with 500V, 200A FP MCCBas incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box withsupporting angles, self locks, gasket having IP54,IK10 protection and slanting topto be erected on provided foundation complete as per specification no. SWSWR/MFP
577DISTRIBUTION BOARDS Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thicknesssurface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbartype) as per specification no. SW-SWR/MCBDB
578Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) asper specification no. SW-SWR/MCBDB
579Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, withdoor, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GIframe as per specification no. SW-SWR/MCBDB
580Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
581Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
582Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
583Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
584Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
585Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
586Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 4 way outgoing or 400A incoming and 2 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
587Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
588Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as perspecification no. SW-RCCB/RCCB
589Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
590ENERGY METERS Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring anddisplay kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history ofEnergy & MD in kW & kVA) with transparent hinge type box complete erectedon polished teak wood board duly wired with required size of weather proofPVC wires duly tested by electric supply company.
591Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company.
592POINT WIRING Point wiring for light/bell concealed type in min 20 mm FRLS grade HMSPVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
593Secondary point wiring for additional light/ bell point, concealed type inmin 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH gradecopper wires with required accessories as per specification No: WG-PW/CW
594Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMSPVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
595Point wiring for independent plug, concealed type in min 20 mm FRLSgrade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copperwires, modular type switch, earthing and required accessories as per specification No WG-PW/SW
596Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW
597Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
598Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
599Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
600Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
601Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
602Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.
603Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete.
604Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.
605Supplying and erecting modular type Two way switch 6A / 10A (2 Module),duly erected on provided plate and box with wiring connections complete.
606Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
607Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
608Supplying and erectingmodular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
609Supplying and erecting unbreakable concealed typemodular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
610Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
611Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
612Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
613Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
614Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
615Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
616Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
617SUB-MAINS WIRING Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
618Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
619Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
620Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/Bus bars or any other placesas per specification No: WG-MA/BW
621Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
622Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.
623Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
624Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010
625Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
626Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
627Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
628LT CABLES & ITS TERMINATION Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core150sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
629Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
630Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
631Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
632Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
633Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
634Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
635Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
636Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
637Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core6sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
638Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
639Supplying and erecting PVC insulated PVC round sheathed 1 sq.mm (32 no. x 0.20mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV
640Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
641Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
642ELV CABLING Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
643Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
644Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with highdensity polyethylene insulation, polyester taped, Nylon Rip Cord & grey coloursheathed with FR PVC, conforming to ITD specification S/WS 113C laid inprovided PVC casing capping/conduit as per specification No. WG-TW
645Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW
646Supplying and erecting LSZH armoured multimode optical fibre cable with 6fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as perspecification no. WG-COC/OFC LSZH
647Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with4-connector channel, performance test report as per ANSI/TIA-568.2-D inposition as per specification No. WG-COC/PC
648Supplying and fixing 2 m UTP patch cord of cat 6 type in position as perspecification No. WG-COC/PC
649FIXTURES & FITTINGS Supplying and erecting LED square / circular Max. 25 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT up to 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
650Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surfaceupto 20W.
651Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 Whaving CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80,CCT up to 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f.>0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
652Supplying and erecting CRCA powder coated corridor / passage light LED fitting (4 feet) Max. 33W with high transitivity diffuser with system lumens output of Min. 4000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT up to 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
653Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCTupto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs.at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
654Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped800mm 8W IP65 & IK10 class having extrusion aluminium housing withpolycarbonate diffuser, having system lumens output of Min. 800 Lumens, min.efficacy of 100 lumen/W, CRI>80, CCT up to 6500K, THD<10%, p.f. >0.90,operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as perspecification No FG-ODF/FLS2.
655Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT up to 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
656Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110lumen/W, CRI>80, CCT up to 6500K, Beam Angle of 120 deg., THD<10%, p.f.>0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVCBlock / wooden board with 3 years warranty.
657Providing & erecting 7 m high (clear height) galvanised octagonal pole withfoundation bolts having bottom of 130 mm A/F, top 70 mm A/F on providedfoundation as per specification no. OH-PL/OPL
658Providing and erecting galvanised 1000mm single arm sword type bracket withFRP dome and ball as per specification no. OH-PL/PBKT
659Providing and erecting galvanised 1000mm double arm sword type bracketwith FRP dome and ball as per specification no. OH-PL/PBKT
660Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including drivercomplete with 3 Years warranty as per specification No FG-ODF/FLS2.
661Making M- 20 grade reinforced cement concrete foundation by consideringthe safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supplyof steel, concrete, excavation and fixing provided nut bolts with the help oftemplate, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole).
662Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/ HM (excluding luminaries)
663Supplying and erecting outdoor stand mounted feeder pillar for high-mast ofthe same manufacturer with 32A TPN MCB incomer, 24hr astronomical timeswitch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TPcontactor for automatic switching of luminaires, 2 no. 9A contactors andraise/lower push button, and provision for termination of adequate size ofincoming and outgoing cables complete erected in min. 14 SWG CRCA sheet boxwith supporting angles, self lock, gasket and slanting top erected on CC foundationcomplete.
664Making M- 20 cement concrete foundation by considering the safe soilbearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixingprovided nut bolts with the help of template, duly plastered as per designcomplete (for 12.5 m raising lowering high mast).
665Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200mm complete erected in position as per specification no. FG-FN/CF
666Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
667Providing recess in brick wall suitable for erection of exhaust fan up to 450mm.sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.
668Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC
669EARTHING Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond with required joints. As per specification no. EA-EP.
670Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
671Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
672Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete.
673Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.
674Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
675Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete withall materials, testing & recording the results as per specification no. EA-EP
676Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no.EA-EP
677Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP
678Providing and back filling ground enhancing compound 25 kg bag complete.
679PA SYSTEM Supplying, erecting, testing and commissioning 120 W amplifier suitable tooperate on 230 Volts A.C. / 12 Volts D.C. supply complete as perspecification no. FF-PA/AFR
680Supplying, erecting, testing and commissioning 15 to 30 Watts soundcolumn or ceiling mounted complete as per specification no. FF-PA/SOC
681Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wirecomplete.
682Supplying, erecting, testing and commissioning stand mounted/handheldtype wired microphone having 2 mV/Pa sensitivity, impedance level limit 300ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min.7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jackcomplete as per specification no. FF-PA/MIC
683Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mmheight and sturdy mechanism ensuring trouble free movement complete.
684LIGHTENING PROTECTION Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
685COMPUTER NETWORK Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS
686Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
687Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK
688EPABX SYSTEM Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 3 x 8 extensions complete.
689Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete
690Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.
691Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
692SOLAR ROOFTOP Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PVSystem / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, signboard, two distinct earthing, lightning arrester, liaising charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
693EV CHARGING STATION Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW ACElectric Vehicle charger (suitable for 2/3/4 wheeler) having minimumIK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3nos. output as per IEC 60309 industrial sockets having capacity of outputcurrent of 16A 240V AC at each socket with 3.5"TFT touch screen for humaninterface & LED Light for status indication and metering for measurement ofconsumed energy having metering accuracy +/-1%, one hour battery backup forcommunication, emergency push stop button and having short circuit, over &under voltage, overload, over temperature, earth leakage protection and enclosuremade of minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frameon provided cement concrete foundation complete with one year on site warranty,confirming to IS 17017 Series as per specification.
694LIFT SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg · Floors :- G+2 floor (3 Stops/3 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0 mps VS Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of 1900mm wide x 1900mm deep, 1900mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe
695Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port.
696The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing.
697· CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. Other mechanical parts such as "T" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.
698· Minor civil work such as alteration work if any necessary for erection of landing door frames and it"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
699REMOVAL OF HT POLES Dismantling the existing pole above 6 m height with brackets, clamps,insulators, stay from the c.c. foundation and making the site clear by refilling thepits with excavated materials and bringing it to the ground level.
700Dismantling the existing overhead line including G.I. wires of all sizes withoutdamaging & making the coils in suitable sizes.
701MISCELLANEOUS ITEMS Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
702Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV
703Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
704Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
705Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
706Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
707Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982
708CABLE TRENCH Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
709Supplying and laying (including excavation of suitable width & depth up to 90cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, to required depth complete.
710Supplying and laying (including excavation of suitable width & depth up to 90cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, to required depth complete.
711Supplying and laying (including excavation of suitable width & depth up to 90 cm)160 mm outside dia, double wall corrugated pipes (DWC) of HDPE forenclosing cable below ground/road surface, to required depth complete.
712Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR
713Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR
714Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram).
715PUMPING SYSTEM Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 3.75 KW/5 HPwith discharge 715/200 Litres per Minute (LPM) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP
716Supplying and erecting minimum Three & above star rated submersible pump set of 5.625 KW/7.5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 100 to 400 LPM discharge at 132 to 27 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP
717Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with novolt coil and overload element with necessary materials and connected to supply up to 7.5 H.P.
718FIRE FIGHTING ARRANGEMENT Supplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m headdriven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 37kW or ofsuitable kW capacity for manual/automatic operation and consisting of following:(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body &bronze impeller with stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation with IP 55 protection for enclosure, horizontal foot mounted typewith Class-"F" insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundationbolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EPEach 207756
719Supplying, installation, testing and commissioning of main fire pump(MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 mhead driven by 76 HP or suitable HP capacity diesel engine at requiredworking speed suitable for manual/automatic operation and consisting offollowing :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body &bronze impeller with stainless steel shaft(SS410 grade), mechanical sealconforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standardcomplete with auto starting mechanism, 12/24 volts DC electric startingequipment with battery of required AH capacity with necessary charger suitable towork on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with firstfilling of diesel up to 100% level with necessary piping with valves up to engine ,exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mmthick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for autostop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith engine assembly and accessories duly painted with two coats of syntheticenamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932of 2003) complete, as per specification no. FF-MFP/SSC/DPEach 599189
720Supplying, installation, testing and commissioning of jockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven byelectric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitablekW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body& bronze impeller with stainless steel shaft (SS410 grade), mechanical sealconforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation with IP 55 protection for enclosure, horizontal foot mounted typewith Class-"F" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation boltsetc. as required.(d) Erected on provided suitable size cement concrete foundation duly plasteredwith anti vibration pads with perfect aligning, proper levelling complete pump setwith accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, asper specification no. FF-MFP/JP
721Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mountedtype with Class-"F" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no.
722Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
723Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
724Supplying and erecting 150 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
725Supplying and erecting 75/80 mm dia cast iron double flange NRV completewith PN16 pressure rating, as per specification no. FF-VL/NRV
726Supplying and installing wall mounting swinging hose reel drum fitted with 19mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
727Supplying and erecting 20/25mm dia gun metal air release cock, withnecessary G.I. coupling to be fitted on top of air vessel or on wet riser completeas per specification no. FF-FFA/ARV
728Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
729Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
730Supplying and erecting M.S./CRCA cabinet for housing single hydrant valveof size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mmmade from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
731Supplying and erecting 63mm dia, controlled percolation (C.P.) hose pipe,15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH
732Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/
733Supplying and erecting fire brigade header ( Siamese connection )of 150 mmdia, for supplying water in fire tank complete as per specification no. FFFA/FMC
734Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I.pipe, elbow etc. complete as per specification no. FF-FFA/PG
735Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
736Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
737Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
738Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
739Supplying, erecting & terminating FR XLPE insulated, galvanised stee formed wire armoured (strip) cable 1100 V, 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
740Supplying, installing, testing and commissioning FR, XLPE armoured cable 2core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
741Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD
742Supplying, erecting testing and commissioning manual call point (Pill box) with break glass, push button (resettable type) in metal enclosure complete as per specification no. FF-FAAS/MCP
743Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR
744Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
745Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP
746Supplying, erecting, testing & commissioning of fire pump control panel (FCP)of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in allrespect, suitable for satisfactory operation of main fire pump and jockey(pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings,suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working ) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitablerating.
747Supplying and erecting 150 mm dia Cast Iron end line strainer of T-Pot typeflanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged,for positive suction complete as per specification no. FF-VL/ELS
748Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
749Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessaryfittings complete as per specification no. FF-PP
750Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessaryfittings complete as per specification no. FF-PP
751Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessaryfittings complete as per specification no. FF-PP
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail