Airports Authority Of India has published Tender For Repair, Maintenance And Operation Of Conventional/Addressable Fire Alarm System With Auto Dialer Facility And Fire Fighting System At Sgrdji Airport, Amritsar (For 2024-2026).. Submission Date for this Tender is 18-03-2024. Alarm Systems Tenders in amritsar Punjab. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Operation and Maintenance Contract ofFire Alarm & Detection System at New Terminal Building, ATC-cum- Tech. Block, New Power House, Cargo Complex, AAI/BCAS Offie Complex, ASR/MSSR & SMR Building, DVOR, Localizer, Glide Path, NDB comprising of control panels, repeater panels, Manual Call Points, Detectors, Hootes, Mimic Panel, PA System, GSM/Landline based Autodialer, Batteries complete circuit & loop wiring etc. i/c all other associated accessories for satisfactory operation & making the system serviceable, periodically cleaning & testing all the associated accessories confirming to OEM specification and Special Terms and conditions attending the breakdown/ faults, preventive maintenance, ensuring serviceablility / satisfactory working condition of the system, maintenance of records / documentation etc. as per the detailed specifications, terms and conditions covered under this contract on all days including Sundays and holidays complete as required. |
2 | Operation and maintenance of Fire hydrant and sprinkler System on around the clock basis with the help ofmanpower as specifiedfor New Terminal Building ,ATC cum Technical Block, AAI/BCAS Office Complex, Air Cargo Complex ; comprising of different capacity of Electric pump motor sets, Diesel Engine Pumpsets, De-watering pumps, Butterfly/sluice Valves,pipe line, Fire Hydrants, Sprinklers etc. as per good engineering practice complete in all respect as requiredand as per specification. |
3 | Replacement of B CheckKit for the following capacity Diesel Enginei/c replacement of multi grade oil as required. |
4 | 118 Kw, Model - 6SL9088T (Kirloskar make) |
5 | Capacity 44.1 KW/ 60 HP , Model - 4R1040 NA (Kirloskar Make) |
6 | 68 kw, Model - 6R1080 (Kirloskar Make) |
7 | Repairing, servicingsluice/ butterfly valves/ NRV etc. of different sizes provided in the fire system at various locations of fire hydrant and sprinkler system as required .(Item will be executed only if required) |
8 | Repairing & servicing of following capacity pump sets after dismantaling and providing all necessary defective/wornout parts such as nut-bolts, rubber gasket, gland dori, rubber coupling, suitable bearings etc. and re- assembling the pump, making the pump set in perfect working condition as per good engineering practice complete in all respect as required at site.(Item will be executed only if required) |
9 | Jockey Pump Set |
10 | Sprinkler Pump Set |
11 | Hydrant pump |
12 | Painting of Fire Hydtant/ Sprinklar pipeline of different sizes installed inside/ outside of terminalbuilding / Cargo Terminal with two or more coats of painting with synthetic enamel paintto give an even shade, including cleaning of surface with detergent etc of approved brand or as approved by engineer-in-charge as required. |
13 | 40 mm Dia |
14 | 80 mm Dia |
15 | 100 mm Dia |
16 | 150 mm Dia. |
17 | 200 mm Dia. |
18 | Supply and fixing offire hydrant/ Sprinkler MS pipe line to bypass leaking underground inaccessible pipe line of following sizes inside/outside of terminal building on surface including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers including MS Fabricated support of suitable size for MS Pipe hanging on wallwith MS Angle, clamps, hangers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. |
19 | 100 mm Dia Class "C" |
20 | 150 mm Dia Class "C" |
21 | 200mm Dia Class "C" |
22 | Supply and laying offire hydrant/ Sprinkler MS pipe line to bypass leaking undergroundin accessible pipe line of following sizes inside/outside of terminal building on ground including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers includingsupport of brick work upto a height of 600 mm from ground surface including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade etc. complete in all respect as required. |
23 | 100 mm Dia Class "C" |
24 | 200mm Dia Class "C" |
25 | Replacement of existing damaged outdoor type hose cabinet by providing and fixing the newhose cabinet ( 1.0 m x 0.55m x 0.85m) made of not less than 3 mm aluminium sheet having central opening glazed door including necessary locking arrangement and painting work including also providing M.S. anglesmounting frame suitable for accommodating external hydrant valve as per site requirement. |
26 | Replacement of the damage door locks of Internal / External Fire Hydrant box. |
27 | Replacement of the damage door glass and aluminium frame of existing External Fire Hydrant box. |
28 | Replacement of Pressure Gauges with new 150/100 mm dial Pressure Gauges including required modification and fixing of New 15 mm control valve and accessories as required at site. |
29 | Replacement of Pressure Switches including required modification, electrical connections, fixing of new 15 mm control valve if required and accessories etc., as per site requirement. |
30 | Constructing masonry chamber 90x90x100 cm inside with 7.5 class designation brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for butterfly/sluice valve with C.I. surface box 100 mm top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix(1cement:2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement : 3 coarse sand), 12 mm thick, finished with a floating coat of neat cement complete as per standard design with FPS bricks. |
31 | Providingand fixingofcast iron butterfly valves of following size on the existing M S Pipes, by cutting, and making exact gap on pipeand fixingincluding flanges, gaskets ,bolt ,nut & washers etc. as required:- |
32 | 200mm dia |
33 | 150mm dia |
34 | 100mm dia |
35 | 80mm dia |
36 | Providing and fixingofNon-Return valve (dual type wafer plate NRV) of following sizeincludingbolt ,nut, washers and rubber gasket as required:- |
37 | 200mm dia |
38 | 150mm dia |
39 | 100mm dia |
40 | 80mm dia |
41 | Providing and fixingofLanding valveof following sizeincludingbolt ,nut, washers and rubber gasket as required:- |
42 | Double Landing valves of 63mm dia |
43 | Providing and fixing of 150 mm dia “C” class MS pipe with 4mm wrapping coating as per IS 1022 : 2008 as required complete in all respect. |
44 | Providing and laying ”C” class M.S. pipeof following size including all forged fittings and accessories complete including welding, jointing and painting with one coat of primer & two coats of post office red enamel paint fixed, including chasing of walls/ columns/ceiling etc. and making good the same complete as required. |
45 | 150mm dia |
46 | 100mm dia |
47 | Providing and Fixing of 150 mm dia Dummy Plate. |
48 | Supply of addressable optical smoke detector. |
49 | Supply of conventional optical smoke detector. |
50 | Supply of addressable multi detector. |
51 | Supply of addressable heat detector. |
52 | Supply of addressable manual call point. |
53 | Supply of loop driver card compatible with existing panel. |
54 | Supply of 12 V, 130 AH sealed maintenance free Battery (Battery Make-as per AAI Approved Make list)) |
55 | Supply of 12 V, 150 AH sealed maintenance free Battery(Battery Make-as per AAI Approved Make list) |
56 | Supply of 12 volt, 26 AH sealed maintenance free battery for fire alarm panels of Terminal buildings/MSSR. |
57 | Supply of 12 volt, 7 AH sealed maintenance free battery for fire alarm panels at NAV AIDS |
58 | Supply of response indicator. |
59 | Supply of Control/ Monitor module. |
60 | Supply of Hose reel Drum for fixing 20 mm dia 30 mtr. Hose reel pipe. |
61 | Supply of 20 mm dia 30 mtr. Hose reel drum pipe. |
62 | Supply of 15 mtr. Hose pipe for hydrant point with male female stainless steel adaptors. |
63 | Supply 63 mm dia Stainless steel (Grade 304) short branch pipe. |
64 | Supply of hydrant cap 63mm Dia |
65 | Supply of Nozzle ring (SS) 63mm Dia |
66 | Supply of hydrant coupling (SS) 63mm Dia |
67 | Supply of Nozzle of hose reel 20mm Dia |
68 | Supply of gland dori (heavy) for main / Jockey pump motor |
69 | Supply of hydrant wheel 63mm Dia |
70 | Supply of coupling lock (small and big) |
71 | Supply of Electonic Hooter Cum Speaker |
72 | Supply of conventional 02 Zone Fire Alarm Panel for NAV AIDS |
73 | Supply of auto dialer for Addressable and Conventional Fire alarm system |
74 | Complete item of chapter 17 & 18 of CPWD schedule rates electrical 2022 (Rates shall be quoted it multiples eg. 0.99 or 1.01% below/above. (Including Labour Cess, operation area charges & excluding GST @ 12%). |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy