Tender For Repairing Up-Gradation Of Signal Barrack For Establishing Office Kote Signal Center And Installation Of Security Lights At Transit Camp Jammu Under Ftr Hq Bsf Kmr, Budgam-Jammu And Kashmir

Border Security Force-BSF has published Tender For Repairing Up-Gradation Of Signal Barrack For Establishing Office Kote Signal Center And Installation Of Security Lights At Transit Camp Jammu Under Ftr Hq Bsf Kmr. Submission Date for this Tender is 09-03-2024. Barrack Tenders in Budgam Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42500661
Tender For Repairing Up-Gradation Of Signal Barrack For Establishing Office Kote Signal Center And Installation Of Security Lights At Transit Camp Jammu Under Ftr Hq Bsf Kmr
Open Tender
Indian
Jammu And Kashmir
Budgam
09-03-2024

Tender Details

Repairing / Up-Gradation Of Signal Barrack For Establishing Office, Kote, Signal Center And Installation Of Security Lights At Transit Camp Jammu Under Ftr Hq Bsf Kmr.

Key Value

Document Fees
Refer document
EMD
INR 7966.0 /-
Tender Value
INR 3.98 Lakhs /-

BOQ Items

Name of Work : REPAIRING/UP-GRADATION OF SIGNAL BARRACK FOR ESTABLISHING OFFICE,KOTE, SIGNAL CENTER AND INSTALLATION OF SECURITY LIGHTS AT TRANSIT CAMP JAMMU UNDER FTR HQ BSF KMR.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B.
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group B.
3Supplying and drawing 3 x 1.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
4Supplying and drawing 3 x 4.0 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
5Supplying and drawing 3 x6.0 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (i)2 X1.5 sq. mm + 1 X 1.5sq. mm earth wire
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (i)2 X4 sq. mm + 1 X 4sq. mm earth wire
8Supplying and fixing of 20 mmmedium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
9Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i) 5/6 A 1 wayswitch
10ii) 3 pin 5/6 A socket outlet
11iii) 15/16 A switch
12iv) 6 pin 15/16 A socket outlet.
13Supplying and fixing two module stepped type electronic fan egulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
14Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C"curve including connections, painting etc. as required.
15Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
16Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
17Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
18Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.i) 63 A
19Supplying and fixing 100 Amps rating, TPN, 440 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
20Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVCsheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3½ X 35 sq. mm (32mm) .
21Providing and fixing 100 A,30KA,FPMCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
22Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
23Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
24Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
25Painting of street light pole (1.5 meter above the ground) with black anti-corrossive bitumastic paint of approved brand and manufacture to give an even shade (one or more coats on old work) Make-Asian/Nerolac/Berger/Dulux-1x0.754=0.754
26Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finish paint etc. as required.
27Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
28Providingand Laying of one Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. ( Make Havells /Polycab/ Finolex)i)3½ X 35 sq sqmm Aluminium conductorarmouredcable. (Havells).
29SITC of 22 W LED LUMILINE 6500 K LED surface and wall mounted LED batten with polycarbonate housing & intregrated electronic driver etc as required ISI marked. Equivalent to model LHEXACP7PN1W022(Havells).
30SITC of 70 watt LED street lights on the existing pole new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07.Make-Havells Model-ENDURASUNDOWNSL70W LED765PASYBOTG Make- Havells/Phillips/Bajaj/Crompton.
31SITC of 100 watt LED Flood lights on the existing shead new generation energy saving and environmental friendly long life LED flood light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07.Make-Havells Model-ETAALBA Flood light 100W Make- Havells/Phillips/ Bajaj/ Crompton.
32SITCof steeltubular pole (swaged type 09 Mtr long 410 SP 28 weight 113KG approx as per IS:2713 (Part I to III)alongwith topcap and 2 meter bracket (32mm) G.I. arm fitted with top end cap) of following specification:-planting depth-1500mm,height above the ground-7500mm, length of section-Bottom:5000mm, Middle:2000mm, Top:2000mm, Out side diameter and thickness of sections:- Bottom:139.7x4.50mm, Middle: 114.3x3.65mm, Top: 88.9x3.25mm) duly welded with steelbase plate size 300 mm x 300 mm x 60mm thick) strut in cement concrete 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded stone aggregate M20 mm grade nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nut, etc as required.
33Painting of 6.5 mtr. height MS pole (Exposed portion) i/c 2 Mtr brackets, loop box etc in erected position with one or more coats of Aluminium paintof approved brandto give an even shade i/c cleaning, scraping, etc complete as reqd.Make-Asian/Nerolac/Berger/Dulu.
34Supplying and fixing of External Loop/Junction box bottom to top openable of size (280 x 170 x 130)mm of FRP material for street light looping, IP65 protection alongwith suitable terminal blocks, Loop-in & Loop-out arrangements for 3x 25sqmm Al Cable, 6-32A SP MCB "B" curve 6kA breaking capacity of 01 Nos, 1 phase bakkelite connector, suitable to fitting with the street light pole with GI clamp, nut, bolts, etc including i/c internal wiring ofloop boxetc as required.
35SITC of AC ceiling fan energy saving of size 1200 mm sweep,Super speed ES 240v,50 Hz complete, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.Make(Bajaj /Orient/Crompton/ Havells)equivalent to model Havells
36S/F of FlameproofLED fixture down light 40 watt are designed to ensure that internal ignition within a flammable atmosphere will not transmit outside the protective enclosure ceilingfittings etc as required equivalent to model FWL1318-40-CDL-M make Crompton / Havell/ Bajaj.etc as required.
37Supplying and fixing 10W LED bulb in the existing holder/wall bracket including connections but excluding modular plate etc. as required. (Havells).