| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" PART-I (B/R WORKS)M&L Rendering (Internal) 12mm thick, in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, Plastered Surfaces finished Even and Smooth without using Extra Cement including taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc and removal of debris outside AF land complete all as specified and as directed. |
| 2 | M&L for preparing New Plastered Surfaces of Walls by applying a Coat of Wall Care Putty, 1.5 mm thick including rubbing down with Sand Paper to obtain a smooth finish surface and applying with rollers Two Coats of Acrylic Distemper (as approved) over a Coat of Primer, complete all as specified and as directed. |
| 3 | M&L for dismantling floor tiles alongwith screed bed, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water and providing Vtirified Ceramic Tiles, 9-10mm thick (Square/ Rectangular), coloured, Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Tiles, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 4 | -ditto- but for vitrified tiles in skirting, fixed over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 5 | -ditto- but for Non-skid/matt finish Ceramic tiles, coloured, 7 to 8 mm thick (Square/rectangular), area of each tile exceedig 0.11 Sqm but not exceeding 0.18 Sqmin Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the tiles, laid over and including Screed Bed 15mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 6 | -ditto- but for Coloured/Printed Glazed Ceramic Tiles, 450x300x7mm thick in Vertical Surfaces i.e. Dado, Skirting, etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, fixed over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:3, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 7 | Taking down PVC Chowkat or Frame of any description (without taking off Shutter from the Frame) not exc. 1.50 Square Metre Each, complete all as specified and as directed. |
| 8 | S&F Solid PVC Door Frame of size 50x47 mm made out of 5.0mm having Wood Grain Printed PVC Sheet reinforced with Mild Steel Square Tube and fixing in opening, complete all as specified and as directed. |
| 9 | M&L Factory Made Solid Panel PVC Door Shutter 30mm thick (Style) Plain colour (Ivory shade) consisting of Frame made out of Mild Steel Tubes for Top and Bottom Rails, Mild Steel Frame shall be covered with heatmoulded wood grain PVC ‘C’ Channel having a PVC Sheet Strip of 20mm width stuck inside with Solvent Cement for Stiles and Wood Grain PVC Sheets for Top Rail, Lock Rail & Bottom Rail on either Side and as gap insert for Top Rail & Bottom Rail, Panelling of Wood grain PVC Sheet to be fitted in the Mild Steel Frame welded/sealed to the Stiles and Rails with suitable 5mm thick x 15mm wide PVC Sheet Beading used inside Stiles and Rails and decorative PVC Beading of 10mm x 10mm (90°) and jointed together with Solvent Cement and fixing in the Frame and hanging/fixing with and including Stainless Steel Hinges, complete all as specified and as directed.NOTE : Stainless Steel Hinges will be Measured and Paid under appropriate Item. |
| 10 | S&F Aluminium Barrel Tower Bolt 150mm long (weight not less than 160 Gram), Extruded Section, complete all as specified and as directed. |
| 11 | S&F Stainless Steel Butt Hinge 75mm long (weight not less than 60 Gram) and fixed, complete all as specified and as directed. |
| 12 | S&F Aluminium Handle 125mm long (weight not less than 90 Gram), Cast type, anodised, complete all as specified and as directed. |
| 13 | Taking down Pressed Steel Frame of any description (without taking off Shutter from the Frame) exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed. |
| 14 | S&F Pressed Steel Frame of size 125x60mm using 1.25mm thick Mild Steel Sheets for Doors with One or More Rebates including necessary Fixing Lugs, Hinges, Lock Strike Plate, etc., complete all as specified and as directed. |
| 15 | M&L Cement Concrete 1:3:6, Type C1 (using 20mm graded stone aggregate) as in Filling Back side of Pressed Steel Frame, complete all as specified and as directed. |
| 16 | M&L for 2nd class hardwood factory made, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces of thickness 35 mm complete all as specified and directed. |
| 17 | M&L for Glazed and Skeleton Shutter, factory made, 35mm thick of Second Class Hardwood prepared to receive Gauge/Glass (without Sash Bars) fixed with mitred beeds supplied and fitted to Chowkat and securing Glass, Gauge, etc. sizes of Members of Shutter as specified in SSR Part-I, Section-8, Clause 8.24(a), complete all as specified and as directed. |
| 18 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed |
| 19 | S&F Aluminium Barrel Tower Bolt 200mm long (weight not less than 210 Gram), Extruded Section, complete all as specified and as directed. |
| 20 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, with length of bolt 250 mm complete all as specified and directed. |
| 21 | S&F Aluminium Handle 150mm long (weight not less than 120 Gram), Cast type, anodised, complete all as specified and as directed. |
| 22 | S&F Floor Door Stopper 150mm in size, Aluminum alloy Body and Tongue with Hard Drawn Steel Spring (weight not less than 90 Gram), complete all as specified and as directed. |
| 23 | S&F Mild Steel 300mm, Ordinary Rat Tail Rod pattern Springs including Roller and Roller Plate and fixed, complete all as specified and as directed. |
| 24 | M&L preparing New Wood and Wood Based Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Coat of Pink Primer, complete all as specified and as directed. |
| 25 | Taking down Steel Window, Ventilator Frame (without taking off Shutter from the Frame) of any description including Guard Bars/ Grill, not exc. 1.00 Square Metre Each, complete all as specified and as directed. |
| 26 | Taking down Steel Window Frame (without taking off Shutter from the Frame) of any description including Guard Bars/ Grill, exc. 1.00 Square Metre but not exc. 2.00 Square Metre Each, complete all as specified and as directed. |
| 27 | S&F Steel windows or ventilators, fixed type, with glazing barscomplete all as specified and as directed.(NOTE: Cost of cutting holes in brick walls and making good to to dismantled portion with cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregates) and finishing with 10 mm thick cement mortar 1:4 shall be demed to be included in the quoted rates. |
| 28 | M&L preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and as directed. |
| 29 | S&F Sheet Glass 4.0mm thick, frosted quality and glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane of Steel Windows, complete all as specified and as directed. |
| 30 | S&F Pressed Mild Steel Shutter 0.75mm thick for Built-in Steel Cup Board, Godrej Pattern, made to Shape and Size as required/ordered at Site, necessary Welding etc. and fixing to Pressed Steel Frame, Locking Device with cover & Mild Steel Handle, Hanging Rod made out from Conduit Pipe 19mm dia, 1.6mm Wall thickness for Built-in Steel Cup Board, Godrej Pattern, including Set of Mild Steel Socket Chromium plated to hold Conduit Pipe Hanging Rod 19mm dia for Built-in Steel Cup Board, Godrej Pattern, inclduding set of Mild Steel Peg Set (Set of 3) for Built-in Steel Cup Board, Godrej pattern,including Spary Painting with Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide Zinc Chrome Primer,complete all as specified and as directed.Note: For measurement purpose, only exposed portion from front to be considered. |
| 31 | S&F Stainless Steel Curtain Rod 25mm dia/bore(as approved) includingfixing stainless steel Bracket (shaped as approved) not less than 80mm longto wall with Screws/ securedwith stainless steel side doom (as approved) fitted/tightened on Curtain Rod at both ends with screw, complete all as specified and as directed. |
| 32 | M&L for Reinforced Cement Concrete 1:2:4 (20mm gradded stone aggre-gate), as in Shelves and the like, complete all as specified and as directed.NOTE : Reinforcement will be Measured and Paid for separately under appropriate Item. |
| 33 | M&L Formwork to Formwork to soffits of suspended slabs such as roof slabs,landings and similar work; not exc 200mm thick (Horizontal or sloping), complete all as specified and as directed. |
| 34 | M&L TMT Bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed. |
| 35 | M&L Aluminium anodised Frame forWindows, Ventilators,etc. having Powder Coating (minimum thickness of Powder coating 50 micron) with one or more rebates including Joining Cleat and beading for fixing, etc., complete all as specified and directed. |
| 36 | M&L for Powder coated (minimum thickness of Powder coating 50 micron) three track aluminium sliding windowwith shutter stiles of size 40mm x20 mm and sheet thickness 1.5mm, having Two shutters of glass and one shutter of wire mesh consisiting ofStainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall be with 100mmx44mmx1.5mm thick section with or without rebate, glazing with 5.5 mm thick tinted/black glass fixed with aluminium beads & neoprene gaskets including providing locking arrangement with each shutter complete all as specified and directed by the Engineer-in-Charge.(NOTE : Size of window shall be as per site requirement. Cost of glass, wire mesh and all fittings & accessories shall be deemed to be included in the quoted rate) |
| 37 | S&F for aluminium anodised decorative grills of size 75mm x 75mm having section width 6mm and 3mm thickness for aluminium windows including all necessary jointing cleats, fixing clips, side channels etc complete all as specified and as directed. |
| 38 | S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:-a) Ceiling Tiles:- Mineral fibre acoustic tile of 16mm thickness having sand textured finish with acoustical punchers, bevelled tegular edge and 8mm drop in module size of 600 x 600mm. Tiles shall have humidity reistance (RH) of 99%, NRC 0.50 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance =85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84.b) Metal Grid:- The grid system shall be 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and |
| 39 | cross tee to cross tee connection shall have a pull out strength of morethan 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long. (MAKE OF CEILING GRID : ARMSTRONG, Model: SUPRAFINE 38 or equivalent in GYPROC / USG BORAL / UNISTEELMAKE OF CEILING TILES: ARMSTRONG, Model: DUNE or equivalent item in GYPROC / USG BORAL / U TONE) |
| 40 | M&L for complete removal of existing treatment on walls, applying 1.5 mm thick Wall Care Putty, Rubbing down with Sand Paper to obtain a Smooth Finish Surface including filling the existing Nails/ Screw Holes, etc. and applying Two Coats of Acrylic Distemper (as approved) over a coat of pimer, with rollers complete all as specified and as directed. |
| 41 | M&L for preparation of old painted concrete or bricksurfaces ofany description over 10 CM girth/width not otherwise described and applying one coat of weather proof exterior emulsion painton external wall surfaces incl cornices, fins, fascia etc complete all as specified & directed. |
| 42 | M&L for preparing Old Treated/Painted Steel and Iron Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 43 | M&L for partition consisting of aluminium anodized sections of 14 gauge thickness with bottom rail of size 114.30mm x 38.10mm and top, centre and vertical rails of size 63.5mm x 38.10 mm including fixing glass panel or PVC board with Rubber Gasket (as approved) and Aluminium Beading 20x3mm size in position complete all as specified and directed. (NOTE: Sheet glass and PVC boarding shall be measured and paid seperately here-in-after. Contractor shall ascertain the required/planned dimensions of partion before quoting his tender. No claim shall be entertained during currency of work) |
| 44 | Supply only 5 mm thick tinted/black glass, cut to size required complete all as specified and directed. |
| 45 | Supply only PVC board, 12 mm thick, cut to size required compete all as specified and directed. |
| 46 | Supply & laying Steel Water Tubing 15mm bore (dia),Galvanised, ‘medium grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other situation, including taking down existing old pipes complete as all specified and as directed. |
| 47 | S&F in repairs Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, Short Body , screwed down, screwed for Iron Pipe or for Brass Ferrule, complete all as specified and as directed. |
| 48 | S&F in repairs Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, Long Body , screwed down, screwed for Iron Pipe or for Brass Ferrule, complete all as specified and as directed. |
| 49 | S&F in repairs Pillar Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type screwed down high pressure,with long screwed Shanks and Fly-nuts, screwed for Iron Pipe, complete all as specified and as directed. |
| 50 | S&F in repairs Angle Valve 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, screwed down, high pressure, screwed both Ends for Iron Pipe , complete all as specified and as directed. |
| 51 | S&F in repairs Angle Valve 15mm bore (dia), Two way, Cast Copper alloy, Chromium Plated, Fancy type, screwed down, high pressure, screwed both Ends for Iron Pipe , complete all as specified and as directed. |
| 52 | S&F in repairs Gun Metal Globe/Gate Valve 20mm bore (dia) with Iron Wheel Head, screwed both Ends for Iron Pipe, complete all as specified and as directed. |
| 53 | S&F in repair Rotational Moulded Polyethene Water Storage Tank, 500 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, conforming to IS, hoisted and fixed in Position complete all as specified and as directed. |
| 54 | S&F in repairs Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe, complete all as specified and as directed. |
| 55 | S&F in repair PVC Connection Pipe 15mm size and 60 Cm in length with Adopter Nuts of PVC, complete all as specified and as directed. |
| 56 | S&F in repairs Vitreous China White Squatting Pan of size 580x440mm, Orissa Pattern with Integral Foot Rests, ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) incluiding provision Concrete Bedding and Making Good to distrubed surfaces complete all as specified and directed. |
| 57 | M&L in repairs PVC Flushing Cistern 10 Litre capacity White, Low Level, Valve less, Syphonic action type with Inlet, Ball Valve, Float and Handle, PVC flush Pipe 32mm bore (dia) of suitable Length, a pair of Cast Iron Bracket/ Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in CM 1:3, complete all as specified and as directed. |
| 58 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, with \"P\" or \"S\" trap front or back inlet, fixing bolts (except flushing cistern and flush pipe) including plastic water closet seat cover (white) and mild steel chromium plated or aluminium hinging device complete all as specified and directed. |
| 59 | S&F in repairs Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back type) with Waste Fitting Brass Chromium plated 32mm dia, PVC Waste Pipe 32mm bore (dia) of suitable Length, a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good disturbed surfaces in Cement Mortar 1:3 complete all as specified and as directed. |
| 60 | S&F in repair Chromium plated brassWall mixer, concealed type, with concealed body, with overhead shower arrangement fixed with 15 mm bore Iron pipe complete all as specified and directed. |
| 61 | S&F in repair chromium plated brass over head shower rose with arm, with 3 flow, fixed to 15mm bore of iron pipe complete all as specified and directed. |
| 62 | S&F in repairs, Tubular towel rail, 20mm dia,600 mm long between flanges including brass chromium plated, complete all as specified and directed. |
| 63 | S&F in repair chromium plated Hand shower (health faucet), ABS body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed. |
| 64 | S&F in repair Looking Mirror 5.0mm thick of size 450x600mm, fixed with Chromium Plated Brass Spacers 25mm to 30mm in size (One Each Corner) including rounding the edges of the Mirror, complete all as specified and as directed. |
| 65 | S&F in repair Glass Shelf (Bath Tray) with bracket, 45 cm long complete all as specified and as directed. |
| 66 | S&F in repair Corner Glass Shelfsingle Decker (Triangular shape) of size 30 Cm with bracket, complete all as specified and as directed. |
| 67 | S&F in repair CP Grating Round 100mm dia jointing with Solvent Cement complete all as specified and as directed. |
| 68 | S&F in repair PVC Floor Trap 75mm bore (dia) with Grating including jointing to Waste Pipe fixed in Cement Concrete 1:2:4 (20mm graded stone aggregate), complete all as specified and as directed. |
| 69 | S&F in repair PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors, complete all as specified and as directed. |
| 70 | S&F in repair PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors, complete all as specified and as directed. |
| 71 | S&F in repair PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls with PVC pipe clips complete all as specified and as directed. |
| 72 | S&F in repair PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls with PVC pipe clips complete all as specified and as directed. |
| 73 | S&F in repair PVC (SWR) Bend 75mm bore (dia), any radius with Access Door, etc. jointing with Solvent Cement , complete all as specified and as directed. |
| 74 | S&F in repair PVC(SWR) Bend 110mm bore (dia), any radius with Access Door, etc. jointing with Solvent Cement, complete all as specified and as directed. |
| 75 | M&L for preparing Old Decorated/Treated Surfaces of Ceiling of any description and applying One Coat of White Wash, complete all as specified and as directed. |
| 76 | M&L Dismantling Stone Slabs and/or Tiles of any description or thickness in Floors, Aprons, etc. laid, bedded and pointed in Cement Mortar, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water and providingGranite (of any type) Tiles, 18-20mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement and admixture of pigment to match the shade of granite stone including grinding and polishing, laid over and including 20mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 77 | -ditto- but for Granite (of any type) Tiles, 18-20mm thick machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement and admixture of pigment to match the shade of granite stone including grinding and polishing, fixed over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:3, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 78 | M&L Dismantling Stone Slabs and/or Tiles of any description or thickness in Floors, Aprons, etc. laid, bedded and pointed in Cement Mortar, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water and providingMachine cut Kota Stone Slab 20-25mm thick in Flooring, laid over 20mm thick Screed base in Cement Mortar 1:4 laid and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 79 | -ditto- but for Machine cut Kota Stone Slab 20-25mm thick in Riser of Steps, Skirting, Dado and Pillar, laid over 10mm thick backing coat of Cement Mortar 1:4 and joined with grey Cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 80 | Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed. |
| 81 | Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed. |
| 82 | Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 83 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 84 | M&L for Brick Work with Fly-AshBricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 85 | M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound(as per manufacturer\"s instructions) onbrick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfacescomplete all as specified and directed.Note : Water Proofing compound shall be measured and paid seperately as \"Supply only\". |
| 86 | Supply only Integral Water Proofing Compound, conforming to IS and/or as approved, complete all as specified. |
| 87 | M&L for preparing New Plastered Surfaces of Walls by applying a Coat of Chalk Whiting (as Preparatory Treatment) and applying Two Coats of Weather Proof Exterior Emulsion Paint over a coat of cement primer with approved Tint as per manufacturer\"s instructions, complete all as specified and as directed. |
| 88 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) as in Coping, Bed Plates, Holdfast, Bed Block, Kerb Stonesincluding necessary Formwork and weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 89 | M&L for Rolled mild steel framed work, Fe-410W (Gde-E-250) quality-B as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering), running rails and guides) and hanging; also fastening and fixing completeall as specified and directed. |
| 90 | M&L for Mild steel plain black sheet in wall cladding steel gates and similar work, cut to size, holes punched including round headed screws etc of sheet thickness 1.00 mm complete all as specified and directed. |
| 91 | M&L for Surface dressing n exc 15 cm deep, in soft.loose soil complete all as specified and directed. |
| 92 | M&L for hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken bricks complete all as specified and directed. |
| 93 | M&L for Cement Concrete 1:3:6 Type C2 (40mm Graded Stone Aggregate) 75 mm thick in Sub-base fo floor etc complete all as specified and as directed. |
| 94 | M&L for providing outdoor ceramic Floor (Paver) Tiles, 300 x 300 x 9.0 to 10mm thick, highly abrasive, Anti-skid, Impact Resistant, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete including providing 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.(NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate. |
| 95 | S&F in position, at or near ground level, factory made precast cement concrete kerb stone blocks, in M-25 grade cement concrete, fixed to the required line, level and curvature, jointed in cement mortar 1:3, including making joints with or without grooves (thickness of joints, except at sharp curves shall not be more than 5 mm) including making drainage opening wherever required complete all as specified and directed. |
| 96 | SCHEDULE \"A\" PART-II (E/M WORKS)Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings (except light fittings) such as switches, ceiling roses, pendants, regulators, sockets, etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditionsseparately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 97 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size (as required) duly painted with Red Oxide Metal Primer and cover plate and frame for mounting MODULAR TYPE Switches, Sockets, Fan Regulators, etc. and Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP incl finishing good disturbed surfaces complete all as specified and as directed. |
| 98 | NOTES :- (1) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same.(2) Quoted rate shall be deemed to be inclusive of the cost of sheet metal terminal box and Modular cover plate with frame as per required size/no. of modules. Quoted rate of point wiring shall be deemed to include for the cost of pressed steel terminal box, modular cover plate and frame.(3) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage.(4) On completion of the wiring work, the contractor shall fill and finish the chases with cement mortar 1:6, apply 2 mm thick wall putty for smooth finish and finish with two coats of acrylic distemper as per existing shade over the conduit layout. Rate quoted by the contractor shall be deemed to include for the above aspect and no claim shall be entertained at a later stage. |
| 99 | All as per item No 96 here-in-beforebut for one 5 pin 5/6 amp socket out let point in the same switch board of light points, fixed to walls/ceiling,for mounting MODULAR TYPE switches |
| 100 | All as per item No 96 here-in-beforebut for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring), fixed to walls/ceiling,for mounting MODULAR TYPE switches |
| 101 | All as per item No 96 here-in-beforebut with 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with cover plate and frame (as per Site requirement) for mounting MODULAR TYPE Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD,incl finishing good disturbed surfaces complete all as specified and as directed. |
| 102 | S&F Modular Switch 1 way 6 A, 1 module complete all as specified and as directed. |
| 103 | S&F Modular Switch 1 way 16 A, 1 module complete all as specified and as directed. |
| 104 | S&F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and as directed. |
| 105 | S&F Modular Socket 6 A/16 A, 2/3 pin combined 2 module complete all as specified and as directed. |
| 106 | S&F Modular Bell push 6A, 2 module complete all as specified and directed |
| 107 | S&F Modular Fan regulator, 5 Step type, 120 watt, 2 module, single pole 230 Volts complete all as specified and as directed. |
| 108 | S&F Modular LED Skirting Light, 230 V, 3 module complete all as specified and directed. |
| 109 | S&F new Ceiling rose, surface type, three terminals complete all as specified and directed |
| 110 | S&F lamp holder with back plate suitable for batten fittings or to be mounted on walls complete all as specified and directed |
| 111 | S&F Call bell, musical type, AC 230/240 Volts, Single Pole complete all as specified and directed. |
| 112 | S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, 110 lumen/watt, operating voltage 180-270 V, with acrylic/polycarbonate diffuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. |
| 113 | -ditto- as per Item No. 110 but of 1 X 09/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt |
| 114 | -ditto- as per Item No. 110 but of 1 X 05 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt |
| 115 | S&F inverter type rechargable LED batten, 10 watt, 2 feet long with battery backup upto 4 hours including connecting up with three core flexible copper wire of suitable size from ceiling rose complete all as specified and directed and complying with the following specifications:- (a) Operating Voltage - 150-300V AC(b) Colour Temperature - 6500 K(c) Type & capacity of battery - Lithium, 2600 mAh(d) Cycle lifetime of battery - 500 times (complete charge & discharge)(e) having in built over voltage and surge protection |
| 116 | S&F LED Bulkhead fitting 09/10 watt, with IP65 degree of protection and with impact resistance of IK-08, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size complete all as specified and directed. |
| 117 | S&F wall light/fixture, stainless Steelbrushed nickel finish fixture with opal Glass diffuser suitable for 9 watt LED lamp B22 Basecomplete incl LED lamp all as specified and directed. (MAKE- HAVELLS (Florentine WL 1LS B22SS) Cat Part No-LHFOAJE1TZ1I060 or equivalent model in other makes specified in tender) |
| 118 | S&F Decorative, wall mounting, antique brass finish fixture with opal glass diffuser suitable for 7.5 W A60 LED filament lamp e27 base complete incl LED lamp all as specified and directed. (MAKE- HAVELLS (Florentine WL 1LS E27 ABR) Cat Part No - LHFOAJD1TZ1T060 or equivalent model in other makes specified in tender) |
| 119 | S&F recess mounted LED luminaire, of size 600 mm x 600 mm, 110 lumen/watt, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V,with constant current electronic drivercomplete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed. |
| 120 | Taking down existing/serviceable fans, sealing cable end, dismantling blades and removing fan and blades and painting of ceiling fans complete, in situ with one coat of synthetic enamel paint by spraying including filing cavities with filler after proper cleaning of all dust, oil, grease etc and re-fixing the ceiling fan by hanging and necessary electrical connections from ceiling rose including testing and commissioning complete all as specified and directed.NOTE: Quoted rate shall be deemed to be inclusive of minor spares such as nuts & bolts, rubber reel, spilt pin, wires etc if required for proper installation and operation of the fans. |
| 121 | Taking down existing unserviceable fans, sealing cable end, dismantling blades and removing fan and blades to MES Store,collect serviceable fans from MES store and fixing the ceiling fans at required locations by hanging and necessary electrical connections from ceiling rose including testing and commissioning complete all as specified and directed.NOTE: Quoted rate shall be deemed to be inclusive of minor spares such as nuts & bolts, rubber reel, spilt pin, wires etc if required for proper installation and operation of the fans. |
| 122 | Supply onlyAnti-suicidal Fan Rod, of size 600 mm, as applicable with Load bearing Capacity 15 to 25Kg comprising / inclusive of the following Specifications :-(a)A pair of Supply Wire(b)Holes for Shackle fitting on Ceiling(c)Hole for Supply Wire bringing out after Inserting Caps(d)Wire to connect to fan motor(e)Hole for Safety screw fittings(f) Holes for Fan Motor Shaft.(MAKE: GOLD LIFE or any other reputed make as approved by GE) |
| 123 | M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC conduit (medium grade) of suitable size, including taking down of old Submain wiring any type including batten/ conduit/casing at any indicated situation complete all as specified and directed.(NOTE : (1) Three runs of single core 10.0 sqmm cable & one run of PVC conduit shall be measured as one unit.(2) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage.(3) On completion of the wiring work, the contractor shall fill and finish the chases with cement mortar 1:6, apply 2 mm thick wall putty for smooth finish and finish with two coats of acrylic distemper as per existing shade over the conduit layout. Rate quoted by the contractor shall be deemed to include for the above aspect and no claim shall be entertained at a later stage. |
| 124 | Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCCBs, MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed. |
| 125 | S&F DB, VTPN, 4 way, vertical type, IP 43 protection, double door (normal range), 415 volts with provision for MCCB (up to 250 Amps) as incomer and MCB as outgoing and electrically connecting up complete all as specified and directed.(NOTE: Incomer MCCB and outgoing MCBs shall be measured and paid separately) |
| 126 | S&F MCCB, 4 pole, 100 Amps, 25 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed. |
| 127 | S&F Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.NOTE: MCB shall be measured and paid separately. |
| 128 | S&F Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.NOTE: MCB shall be measured and paid separately. |
| 129 | S&F MCB, \"C\" series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed. |
| 130 | S&F MCB, \"C\" series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. |
| 131 | S&F exhaust fan 380 mm sweep, 900 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, with louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as spcified and directed.(MAKE : HAVELLS, Model: Turbo Force / CROMPTON, Model: EXHD380-6-1 / USHA, Model: Turbo Heavy Duty or equivalent model in BAJAJ / ALMONARD / ORIENT)NOTE :- Old unsv fan, if existing shall be taken down and deposited by contractor in MES store. Quoted rate shall be deemed to be inclusive of the aspect. |
| 132 | Supply, installation, testing and commissioning of heater water storage type electric geyser (vertical cylindrical type) 25 litres capacity with BEE 5 star rating (min) and ABS body, glass lined/titanium enamel coated inner tank incl fixing arrangement, clamps, nuts & bolts etc along with providing suitable capacity flexible cable 3 core with 3 pin plug of 16 amps and stainless steel connection pipes of adequate length complete all as specified and directed.(MAKE: RACOLD, Model - CDR DLX / AO SMITH, Model - ELEGANCE PRIME / HAVELLS, Model: FABIA / BAJAJ, Model: CALDIA)NOTE: Cost of cable, plug top and SS connection pipes shall be deemed to be included in the quoted rate. |
| 133 | S&F Desert Cooler, floor mounted with castors, with 5 blades,plastic/PVC body honeycomb type cooling media, 95 Litre water tank capacity, 3 speed, minimum 3600 cubic metre/hour air delivery, aluminiumwounded motor 230 V, 50 HZ with all standard accessories viz motor/ pump /fan blades etc complete all as specified and directed.(MAKE - HAVELLS, Model : KACE 95 / SYMPHONY, Model: Windblast 95 EX Desert Air Cooler / USHA, Model : DESERT AIR COOLER RACER 95 L 95RD1 / BAJAJ, Model : DMH 95 Air Cooler) |
| 134 | Supplying, assembling and fixing modular AC power unit comprising of 01 No 16 Amps socket and 01 No 32 Amps SP MCB, 3 modules along with GI metallic flush box, cover plate and frame duly concealed in wall complete all as specified and directed.NOTE: Quoted rate shall be deemed to include for the cost of MCB, socket, GI flush box, cover plate & frame. Concealed conduit wiring shall be measured seperately. |
| 135 | S&F 32 Amps modular motor starter with cover plate & frame, 2 modules along with GI metallic flush box duly concealed in wall complete all as specified and directed.NOTE: Quoted rate shall be deemed to include for the cost of cover plate & frame and GI flush box alongwith starter. Concealed conduit wiring shall be measured seperately. |
| 136 | Disconnecting and Taking down carefully indoor /outdoor unit of Split Type Air Conditioner, any tonnagewith all connected accessories, cleaning/servicing and refixing the same at a new location in the same building (as directed) including making suitable hole in wall incl testing and commissioning complete all as specified and directed.(NOTE: Cost for complete servicing with gas topping as required/repairing/copper tube upto 10 mtr length/cutting chasing/ fasterners/nut bolt/fixing platesand making good to exisitng surfaces are deemed to be included in the quoted rates. |
| 137 | Supply, installation, testing and commissioning ofLT Panel,Outdoor Typeconfirming to IS 8623 Part I (one), fabricated in a CPRI approved factory,totally enclosed vermin proof suitably ventilated for 3 phase, 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3mm thick CRCA sheet & MS angle sectionof suitable sizefor frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coatingand powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size, the required no of holes to be fixed with chromium plated brass cable glands of suitable size for entry and exit. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided . EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support requiredwith four legs 60 cm long using angle iron 40x40x6mm, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, legs grouted in PCC 1:2:4 and making good disturbed |
| 138 | surface complete and comprising of the following :-A. (i) TPN Copperelectrolyticgrade busbar of capacity 300 Amps for phases & 250 Amps for neutral.and auxillary busbar to support main busbar. duly supported on SMC/DMC, busbar supports and insulatedwith colour coded heat shrinkable sleeve.(ii)Digital multifunction meter (V,A,KW,KWH),415V AC alongwith C.T’s of suitable ratio (set of three), class 1.0, complete. (iii) Indication lamps LED type (RYB)= 01 Set of three. CTs 500/5A class 1.0,15VA (Cast Resin) for metering-03 nos.(iv)Internal wiring with suitable size FRLS copper conductor cable.B. INCOMER:-(i) MCCB 160 Amp 4 pole, 16 KA , Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase seperator - 01 nos C. OUTGOING : (i) MCCB63A amp 4 pole, 16 KA, Ics=100% Icu ,with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperator- 02 nos |
| 139 | NOTES: (i) Contractor shall submit the followingTest report i.e. IP Test Report and verification of short circuitwithstand test report issued by CPRIin respect of LT Panel.(ii) Contractor shall submit drawing for approval prior to placing order. |
| 140 | Supply, Laying and testingXLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing complete of the following sizes and cross sectional area :- (Note :-Necessary earth work to be measured and paid separately. |
| 141 | 95 Sqmm, 3.5 core |
| 142 | 35 Sqmm, 3.5 core |
| 143 | 10 Sqmm, 2 core |
| 144 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) up to 180mm thickness, complete all as specified and as directed.NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. |
| 145 | Supply and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat,size 230mm x 115mmx 75mm, complete all as specified anddirected. |
| 146 | Supply & Laying HDPE pipes, conforming to IS-4984, 25 mm OD, PN 10 with all fittings, laid in trenches for protection of cable complete all as specified and as directed |
| 147 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia(up to 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed. |
| 148 | S&F in repairs LED Street Light fitting, 35/36 watt capacity, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-.(a) minimum system efficacy 120 lumen/watt(b) CRI not less than 70, (c) THD < 10%(d) Power Factor not less than 0.90(e) having in built short circuit and surge protection upto 4 kV(f) having 10 KV external surge protection (for 45 watt & above)(g) colour temperature not less than 5700 degree K(h) life not less than 50000 hours of operationNOTE: Wire for connection of luminaire shall be measured and paid seperately. |
| 149 | S&F in repair Bracket/Arm suitable for street light fittings, made out of 25 mm bore (light grade) GI pipe length not exceeding 1.20 metre long, fixed with 02 sets of flat iron clamp of size 40mm x 6 mm, with bolts, nuts and washers of suitable size including applying two coats of synthetic enamel paint on MS sections over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed. |
| 150 | S&F in repair LED post top luminiare, 15 watt, with die cast amuninium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver complete all as specified an directed.(Make : HAVELLS, Model: RUBY or equivalent model in other makes specified in tender) NOTE: Wire for conection of luminaire shall be measured and paid seperately. |
| 151 | S&F in repairs LED pathway luminare, 9/10 watt, in powder coated ERW MS tubular/square sections, with cylindrical diffuser on top complete, IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work (1:2:4 Type B1) complete all as specified and directed. (Make : BAJAJ, Cat No: BGBOL 605 9W LED WW / CROMPTON, Cat No: LBLA1-10-CDL / HALONIX, Cat No: HLOB-02-10-CW / SURYA, Cat No: SLE BL 9W-GLZ600/EVEREADY, Model: IRIS / ORIENT, cat No: OBL-QUINN9W760 or equivalent model in other makes specified in particular specifications)NOTE: Wire for connection of luminaire shall be measured and paid seperately. Cost of PCC base is deemed to be included in the quoted rates. |
| 152 | S&F in repairs PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1.50 sqmm, 3 core,1100 Volt, conforming to IS 694all as specified and directed |
| 153 | S&F polycarbonate junction box with metric knockouts, of size 130 mm x 180 mm x 77 mm with bakelite terminals, suitable for 10 Sqmm cable complete with dust / water proof and with IP 65 protection complete all as specified and directed. (MAKE : HENSEL, Cat No. KF 1010G or equivalent model in SPELSBERG / SCHNEIDER / RITTAL) |