Replacement And Enhancement Of Existing Ductable Ac System To Sri Parthasarathi Swamy Temple And Sri Andal Ammavari Temple In Sri Gt, Tirupati , Supply Installation Of 11Tr Air Cooled Condensing Unit Consisting Of Scroll Compressor, Copper Condenser Coil Of Copper Tubes And Blue Hydrophilic Coated Aluminium Fins, Condenser Fans, Etc. Suitable For Operating An Eco-Friendly Refrigerant R-407C Including Necessary Accessories Civil Pedestals Bricks, Like Rubber Pads. Make: Voltas / Blue Star / Carrier, Supply Installation Of 8.75Tr Air Cooled Condensing Unit Consisting Of Scroll Compressor, Copper Condenser Coil Of Copper Tubes And Blue Hydrophilic Coated Aluminium Fins, Condenser Fans, Etc. Suitable For Operating An Eco-Friendly Refrigerant R-407C Including Necessary Accessories Like Rubber Pads And Civil Pedestals Bricks. Make: Voltas / Blue Star / Carrier, Supply, Installation Of Double Skin Vertical Floor Mounted Dx Ahu With 10Mcron-50Mm Thick Pre Filter, Coil And Fan Section, 25Mm Thick Puff Insulation, Panel Inner 0.6Mm Gi Plain And Outer 0.6Mm Thick Pre Coated, Aluminium Extruded Frame With Nylon Corners With Hollow Profile, Didw Forward Curved Fan, 3 Phase, Ie2 Motor 3 / 8 Inch Dia, 6 Row Dx Cooling Coil With Aluminium Finned Copper Tube Along With Ss Drain Pan. Capacity: 4400 Cfm, 50Mm Sp And Necessary Civil Pedestals Bricks, Rubber Pads And Including Buy Back Of Old Ahu And Condensing Units Along With Cables And Copper Pipe. Fan Makes:Nicotra / Kruger Motor Makes:Cg / Abb Ahu Unit Makes : System Air / Sagar Air / Edgetech, Supply And Installation Of Double Skin Vertical Floor Mounted Dx Ahu With 10Mcron-50Mm Thick Pre Filter, Coil And Fan Section, 25Mm Thick Puff Insulation, Panel Inner 0.6Mm Gi Plain And Outer 0.6Mm Thick Pre Coated, Aluminium Extruded Frame With Nylon Corners With Hollow Profile, Didw Forward Curved Fan 3 Phase, Ie2 Motor 3 / 8 Inch Dia, 6 Row Dx Cooling Coil With Aluminium Finned Copper Tube Along With Ss Drain Pan. Capacity: 3200 Cfm, 50Mm Sp And Necessary Civil Pedestals Bricks, Rubber Pads And Including Buy Back Of Existing Ahus, Condenser Units Along With Copper Piping. Fan Makes:Nicotra / Kruger Motor Makes:Cg / Abb Ahu Unit Makes: System Air / Sagar Air / Edgetech, Supply And Installation Of Microprocessor Based Electrical Panel With Suitable Rating Incoming Mccb With Digital Kwh Meter And Outgoing Feeders With Suitable Rating Mcbs To The 1 No 11 Tr Condensing Units And 1 No. Ahu Make:Softhard / Bluevolt / Chaya Switch Gear, Supply And Installation Of Microprocessor Based Electrical Panel With Suitable Rating Incoming Mccb With Digital Kwh Meter And Outgoing Feeders With Suitable Rating Mcbs To The 1 No 8.75 Tr Condensing Units And 1 No. Ahu Make:Softhard / Bluevolt / Chaya Switch Gear, Supply, Installation Of 18G Hard Drawn Copper Refrigerant Piping, Duly Insulated With Closed Cell Elastomeric Nitrile Rubber Insulation, Class-O Covered With Complete With Necessary Fittings 5 / 8 Inch ( 15.8Mm ) Liquid Line, Supply, Installation Of 18G, Hard Drawn Copper Refrigerant Piping, Duly Insulated With Closed Cell Elastomeric Nitrile Rubber Insulation, Class-O, Covered With Complete With Necessary Fittings.11 / 8 Inch ( 28.5Mm ) Suction Line, Supply And Installation Of Suitable New Thermostatic Expansion Valve And Catch All Filter Driers Along With Necessary Fittings, Supply And Charging Of Additional Refrigerant R407c, Pressure Testing, Vaccumising And Commissioning Of The Units, Integration And Uploading Software In Existing Microprocessor By The Oem Engineer For 11Tr System, Pressure Testing, Vaccumising And Commissioning Of The Units, Integration And Uploading Software In Existing Microprocessor By The Oem Engineer For 8.5Tr System., Supply , Installation Of Power And Control Cable Of 3C 1.5 Sqm Cu Armoured Cable. Make : Poly Cab / Finolex., Supply , Installation Of Power And Control Cable Of 4C 6Sqmm Cu Armored Cable Make : Poly Cab / Finolex., Supply , Installation Of Power And Control Cable Of 5C 1.5 Sqm Cu Armored Cable Make : Poly Cab / Finolex., Supply And Installation Of 8-Swg Gi Earthing, Supply, Fabrication, Installation Of Necessary Ducting And Canvas Connection To Ahu For 11Tr System., Supply, Fabrication, Installation Of Necessary Ducting And Canvas Connection To Ahu For 8.5 Tr System, Dismantling, Shifting Of Air Handling Unit And Condensing Units, Copper Pipe And Cables ( Ahu-1No, Odu-1No ) Of 7.5 Tr Unit, Dismantling, Shifting Of Air Handling Unit And Condensing Units Along With Copper Piping ( Ahu-1No, Odu-1No ) Of 5.5 Tr Unit