| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-07-2024 | Notice for Technical Bid Opening on 11th July, 2024 | Technical Bid | 11-07-2024 |
| 2 | 11-06-2024 | Extension of bid submission date to July 11th, 2024 | Date | 11-07-2024 |
| 3 | 07-06-2024 | Notice for Technical Bid Opening for DRIP-II (Package-VI) | Technical Bid | 11-06-2024 |
| 4 | 10-05-2024 | Extension of bid submission date to 11th June 2024 | Date | 11-06-2024 |
| 5 | 06-05-2024 | Notice for Technical Bid Opening | Technical Bid | 10-05-2024 |
| 6 | 10-04-2024 | Extension of bid submission date | Date | 10-05-2024 |
| 7 | 04-04-2024 | Notice for Technical bid opening | Technical Bid | 10-04-2024 |
| 8 | 07-03-2024 | Pre-bid meeting notice for the work Rehabilitation and Improvement of Basic Facilities of Myntdu Leshka Stage-I Dam in West Jaintia Hills District of Meghalaya under DRIP-II (Package-VI) | Other | 10-04-2024 |
| Sl. No. | Item Description |
| 1 | Construction of RCC Building for Security Personnel at Myntdu Leshka Dam Site. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In all kind of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up consolidating each deposited layer by ramming and watering, lead up 1to 50m and lift upto 1.5m. |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: Mix 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal nsize. |
| 6 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: Mild steel and Medium Tensile steel bars. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of works for: |
| 11 | (a) Foundation, footing, base of column, Pile cap, raft and mass concrete works etc. |
| 12 | (b)Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 13 | (c)Column, pillars, piers, abutments, posts & struts. |
| 14 | (d)Suspended floors, roofs, landings, balconies and access platform. |
| 15 | (e)Stairs, (excluding landings) except spiral-staircases. |
| 16 | (f)Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 17 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Mix 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 18 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 20 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand: With modular brick. |
| 21 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately):Second class teak wood. |
| 22 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment): Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 23 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: G I Pipe (48.3mm dia). |
| 24 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 25 | Cement plaster of mix 1:4 (1 cement : 4 fine sand): 20 mm thick. |
| 26 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement: 20 mm cement plaster. |
| 27 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement: 18 mm thick. |
| 28 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 29 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size). |
| 30 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 32 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement @ 3.3 kg/sqm including pointing the joints with cement and matching pigments etc., complete. |
| 33 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over the 0.50Sqm |
| 34 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) :Second class teak wood - 35mm thick shutter. |
| 35 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : Size-125x64x2.50 mm. |
| 36 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:Size- 250x10mm. |
| 37 | Providing and fixing bright finished brass handles with screws etc. complete:Size- 125mm. |
| 38 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : Size-250x10x5mm. |
| 39 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes. |
| 40 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 41 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 42 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. |
| 43 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 44 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge: 15 mm nominal dia. |
| 45 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: Medium. |
| 46 | Providing and fixing Toilet paper Holder: Medium. |
| 47 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour: 600mm Towel rail. |
| 48 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board Size 510x1040 mm bowl depth 250 mm |
| 49 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete: Flexible pipe - 40 mm dia. |
| 50 | Providing and fixing soil, waste and vent pipes:(a ) 100mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 51 | Providing and fixing soil, waste and vent pipes:(b)75mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 52 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: |
| 53 | (a)100 mm dia. |
| 54 | (b)75 mm dia. |
| 55 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100x100x100mm. Sand cast iron S&S as per IS - 1729 |
| 56 | Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100x100x75 mm. Sand cast iron S&S as per IS - 1729 |
| 57 | Providing and fixing terminal guard: |
| 58 | (a) 100 mm - Sand cast iron S&S as per IS – 1729. |
| 59 | (b) 75 mmdia. PVC cowl of ISI make. |
| 60 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet. Sand cast iron S&S as per IS: 3989 |
| 61 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms |
| 62 | Providing and fixing PTMT Bottle Trap for Wash basin and sink:Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. |
| 63 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer. |
| 64 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm. |
| 65 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 66 | Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 67 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat). |
| 68 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 69 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank: 1000 litre capacity. |
| 70 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold-water supply including all CPVC plain and brass threaded fitting. This includes jointing of pipes and fitting, with one step CPVC solvent cement, trnching, refilling & testing of joints complete as per direction of Engineer in charge. |
| 72 | Supplying and fixing gun metal gate valvwith CI wheel approved quality (screw end):25 mm nominal bore |
| 73 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931:15mm nominal bore |
| 74 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15mm nominal bore |
| 75 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15mm nominal bore |
| 76 | Septic Tank 40. |
| 77 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 78 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:Mix 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal nsize. |
| 79 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With modular bricks. |
| 80 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 81 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Mild teel and Medium Tensile steel bars. |
| 82 | Centering and shuttering including strutting, propping etc. and removal ofworks for: |
| 83 | (a)Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 84 | (b)Suspended floors, roofs, landings, balconies and access platform:Thickness of floors/slab upto 200 mm. |
| 85 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with Mix1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 86 | Cement plaster of mix 1:4 (1 cement : 4 fine sand):20mm thick |
| 87 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:Mix 1:2:4 (1 cement:2 coarse sand (Zone III) : 4 graded stone aggregate 20mm nominal nsize. |
| 88 | Providing and fixing soil, waste and vent pipes:100mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 89 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete:100 mm dia - Sand cast iron S&S as per IS - 1729 |
| 90 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 91 | Internal Electrification Wiring of RCC Building for Security Personnel at Myntdu Leshka Dam Site |
| 92 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 93 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 94 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 95 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 96 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 97 | (a) 5/6 A switch |
| 98 | (b) 15/16 A switch |
| 99 | (c) 3 pin 5/6 A socket outlet |
| 100 | (d) 6 pin 15/16 A socket outlet |
| 101 | (e) Bell push |
| 102 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 103 | (a) 3module (100mmx75mm) |
| 104 | (b) 6 module (100mmx75mm) |
| 105 | Supplying and fixing brass batten/ angle holder including connection etc as required. |
| 106 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 107 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 108 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 109 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required: 63A TP&N |
| 110 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, but without MCB/RCCB/Isolator:8 way (4 + 24), Double door |
| 111 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:Double pole |
| 112 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required:63Amp |
| 113 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 114 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 115 | Construction of RCC Building for Site Personnel at Myntdu Leshka Dam Site. |
| 116 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In all kind of soil. |
| 117 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up consolidating each deposited layer by ramming and watering, lead up 1to 50m and lift upto 1.5m. |
| 118 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 119 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: Mix 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal nsize. |
| 120 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 121 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more.In foundation upto Plinth |
| 122 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more.Above plinth |
| 123 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: Mild steel and Medium Tensile steel bars.Ground Floor & 1st floor |
| 124 | Centering and shuttering including strutting, propping etc. and removal ofworks for: |
| 125 | (a) Foundation, footing, base of column, Pile cap, raft and mass concrete works etc. |
| 126 | (b)Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 127 | (c)Column, pillars, piers, abutments, posts & struts. |
| 128 | (d)Suspended floors, roofs, landings, balconies and access platform. |
| 129 | (e)Stairs, (excluding landings) except spiral-staircases. |
| 130 | (f)Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 131 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a) 1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 132 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :(a) 1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 133 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 134 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): (a) With modular brick. |
| 135 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Second class teak wood. |
| 136 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectioFixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).nal weight of only steel members shall be measured for payment). |
| 137 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.(a)G I Pipe |
| 138 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 139 | Cement plaster of mix 1:4 (1 cement : 4 fine sand):20 mm thick. |
| 140 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement:20 mm cement plaster:20 mm cement plaster: |
| 141 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement:18 mm thick |
| 142 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 143 | Providing and laying damp-proof course 40mm thick with cement concrete mix1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size). |
| 144 | Making plinth protection 50mm thick of cement concrete mix 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 145 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 146 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement @ 3.3 kg/sqm including pointing the joints with cement and matching pigments etc., complete. |
| 147 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels:Granite of any colour and shade:Area of slab over tha 0.50 Sqm. |
| 148 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood - 35mm thick shutter. |
| 149 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : Size- 125x64x2.50 mm |
| 150 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :Size- 250x10mm |
| 151 | Providing and fixing bright finished brass handles with screws etc. complete.Size- 125mm |
| 152 | Providing and fixing bright finished brass door latch with necessary screws etc. complete :Size- 250x10x5mm |
| 153 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes |
| 154 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 155 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 156 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 157 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 158 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge:15 mm nominal dia |
| 159 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Medium |
| 160 | Providing and fixing Toilet paper Holder:Medium |
| 161 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour:600mm Towel rail |
| 162 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board- Size 510x1040 mm bowl depth 250 mm. |
| 163 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete:Flexible pipe - 40 mm dia |
| 164 | Providing and fixing soil, waste and vent pipes:(a)100mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 165 | Providing and fixing soil, waste and vent pipes:(b)75mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 166 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete:(a)100 mm dia |
| 167 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete:(b)75 mm dia. |
| 168 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100mm Sand cast iron S&S as per IS - 1729 |
| 169 | Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x75 mm Sand cast iron S&S as per IS - 1729 |
| 170 | Providing and fixing terminal guard :(a) 100 mm - Sand cast iron S&S as per IS - 1729 |
| 171 | Providing and fixing terminal guard :(b) 75 mmdia. PVC cowl of ISI make |
| 172 | Providing and fixing trap of self-cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989 |
| 173 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77mm.breadth, weighing not less than 60 gms |
| 174 | Providing and fixing PTMT Bottle Trap for Wash basin and sink:Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. |
| 175 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer. |
| 176 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm. |
| 177 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 178 | Applying priming coat.With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 179 | Applying priming coat.With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat). |
| 180 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 181 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank: 1000 litre capacity. |
| 182 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 183 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold-water supply including all CPVC plain and brass threaded fitting. This includes jointing of pipes and fitting, with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. |
| 184 | Supplying and fixing gun metal gate valve with CI wheel approved quality (screw end):25 mm nominal bore |
| 185 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931:15mm nominal bore |
| 186 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms:15mm nominal bore |
| 187 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15mm nominal bore |
| 188 | Septic Tank 40 User. |
| 189 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil. |
| 190 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:Mix 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal nsize. |
| 191 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With modular bricks. |
| 192 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 193 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Mild teel and Medium Tensile steel bars. |
| 194 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(a)Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 195 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(b)Suspended floors, roofs, landings, balconies and access platform- Thickness of floors/slab upto 200 mm |
| 196 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 197 | Cement plaster of mix 1:4 (1 cement : 4 fine sand) - 20mm thick. |
| 198 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:Mix 1:2:4 (1 cement:2 coarse sand (Zone III) : 4 graded stone aggregate 20mm nominal nsize. |
| 199 | Providing and fixing soil, waste and vent pipes :100mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 200 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete:100 mm dia - Sand cast iron S&S as per IS - 1729 |
| 201 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 202 | Internal Electrification Wiring. |
| 203 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 204 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 205 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 206 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 207 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 208 | (a) 5/6 A switch |
| 209 | (b) 15/16 A switch |
| 210 | (c) 3 pin 5/6 A socket outlet |
| 211 | (d) 6 pin 15/16 A socket outlet |
| 212 | (e) Bell push |
| 213 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.(a) 3 module (100mmx75mm) |
| 214 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.(b) 6 module (100mmx75mm) |
| 215 | Supplying and fixing brass batten/ angle holder including connection etc as required. |
| 216 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 217 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 218 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 219 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63A TP&N |
| 220 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ISO)8 way (4 + 24), Double door |
| 221 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 222 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63Amp |
| 223 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 224 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 225 | RENOVATION OF THE SITE OFFICE OF THE ASSISTANT EXECUTIVE ENGINEER MLCSD-III NOHKUM |
| 226 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In all kind of soil. |
| 227 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up consolidating each deposited layer by ramming and watering, lead up 1to 50m and lift upto 1.5m. |
| 228 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 229 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In Mix proportion 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal size. |
| 230 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: In Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 231 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: With Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 232 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(a) Foundation, footing, base of column, Pile cap, raft and mass concrete works etc. |
| 233 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(b) Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 234 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(c) Column, pillars, piers, abutments, posts & struts. |
| 235 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(d) Suspended floors, roofs, landings, balconies and access platform. |
| 236 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : In Mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 237 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : In Mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 238 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With modular bricks. |
| 239 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately): With Second class teak wood. |
| 240 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment): With Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 241 | Cement plaster of 20 mm thick of mix 1:4 (1 cement : 4 fine sand) |
| 242 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 243 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth: 50mm thick in proportion 1:4:8 |
| 244 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 245 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement @ 3.3 kg/sqm including pointing the joints with cement and matching pigments etc., complete. |
| 246 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately): Second class teak wood - 35 mm thick shutter. |
| 247 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : Size - 125x64x2.50 mm |
| 248 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : Size - 250x10mm |
| 249 | Providing and fixing bright finished brass handles with screws etc. Complete: Size - 125mm. |
| 250 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : Size - 250x10x5mm. |
| 251 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 252 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: With White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 253 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: With White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. |
| 254 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 255 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge: With 15 mm nominal dia |
| 256 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: Medium size. |
| 257 | Providing and fixing Toilet paper Holder: Medium size. |
| 258 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour: 600mm Towel rail. |
| 259 | Providing and fixing P. V .C. waste pipe for sink or wash basin including P. V. C. waste fittings complete with Flexible pipe - 40 mm diameter. |
| 260 | Providing and fixing soil, waste and vent pipes:(a) 100mm dia- Sand cast iron S&S pipe as per IS: 1729 |
| 261 | Providing and fixing soil, waste and vent pipes:(b) 75mm dia- Sand cast iron S&S pipe as per IS: 1729 |
| 262 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete(a) 100 mm dia- Sand cast iron S&S as per IS - 1729 |
| 263 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete(b) 75 mm dia- Sand cast iron S&S as per IS - 1729 |
| 264 | Providing and fixing single equal plain junction of required degreewith access door, insertion rubber washer 3 mm thick, bolts and nuts complete: With 100x100x100mm - Sand cast iron S&S as per IS - 1729. |
| 265 | Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : With 100x100x75mm- Sand cast iron S&S as per IS - 1729 |
| 266 | Providing and fixing terminal guard : With 100mm Sand cast iron S&S as per IS - 1729. |
| 267 | Providing and fixing terminal guard : With 75mm - Sand cast iron S&S as per IS - 1729 PVC cowl of ISI make. |
| 268 | Providing and fixing trap of self-cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: With 100 mm inlet and 100 mm outlet- Sand cast iron S&S as per IS: 3989. |
| 269 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: With Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms. |
| 270 | Providing and fixing PTMT Bottle Trap for Wash basin and sink: |
| 271 | Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. |
| 272 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : With Water thinnable cement primer. |
| 273 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm. |
| 274 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : With Two or more coats on new work. |
| 275 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 276 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat). |
| 277 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : With Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture. |
| 278 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank: With 1000 litre capacity. |
| 279 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge: Internal works - exposed on wall with 20mm nominal outer dia Pipes. |
| 280 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fitting. This includes jointing of pipes and fitting, with one step CPVC solvent cement , trenching, refilling & testing of joints complete as per direction of Engineer in charge. |
| 281 | Providing and fixing gun metal gate valve with C.I wheel approved quality (screwed end): With 25 mm nominal bore. |
| 282 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931: With 15mm nominal bore. |
| 283 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms: With 15mm nominal bore. |
| 284 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: With 15mm nominal bore. |
| 285 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 286 | Dismantling roofing including ridges, hipes valleys and gutters etc. And stacking the materials within 50meters lead of: In G.S. Sheet. |
| 287 | Demolishing wood work in frames, trusses, purlins, and rafters upto 10 meters span and 5 meters height including stacking the materials within 50 metres lead: Of sectional area 40 square centimeter and above. |
| 288 | Dismantling Door, Windows, Celestory windows (steel or wood) shutter including chawkat architrave, holdfast etc. complete and stacking within 50 metre lead: area 3 Sq, metres and below. |
| 289 | Demolishing cement concrete manually/ by mechanical means including disposal of materials within 50 metres lead as per direction of Engineer-in-charge : In Nominal concrete 1:3:6 or richermiox (i/c equivalent design mix). |
| 290 | Demolishing dry brick pitching in floor, drain, etc. including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead. |
| 291 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :In cement mortar. |
| 292 | Septic Tank. |
| 293 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In All kinds of soil. |
| 294 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level: In Mix proportion 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal nsize. |
| 295 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): With modular bricks. |
| 296 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: With Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 297 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: With Mild Steel and Medium Tensile steel bars. |
| 298 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(a) In Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 299 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(b) In Suspended floors, roofs, landings, balconies and access platform. Thickness of floors/slab up to 200 mm. |
| 300 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement: In mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 301 | 20mm cement plaster of mix 1:4 (1 cement : 4 fine sand) |
| 302 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In Mix proportion 1:2:4 (1 cement:2 coarse sand (Zone III) : 4 graded stone aggregate 20mm nominal size. |
| 303 | Providing and fixing soil, waste and vent pipes: With 100mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 304 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: With 100 mm dia - Sand cast iron S&S as per IS - 1729 |
| 305 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 306 | Internal Electrification. |
| 307 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required: Group C- Long wiring up to 10.00m. |
| 308 | Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 309 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 310 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: With 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 311 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: |
| 312 | (a)5/6 A switch |
| 313 | (b)15/16 A switch |
| 314 | (c)3 pin 5/6 A socket outlet |
| 315 | (d)6 pin 15/16 A socket outlet |
| 316 | (e)Bell push |
| 317 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(a)3 module (100mmx75mm) |
| 318 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(b)6 module (100mmx75mm) |
| 319 | Supplying and fixing brass batten/ angle holder including connection etc as required. |
| 320 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 321 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 322 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 323 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required: With 63A TP&N. |
| 324 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required: With 8 way (4 + 24), Double door. |
| 325 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: With Double pole. |
| 326 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required: With 63Amp. |
| 327 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 328 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 329 | Boundary Fencing at the Office of the Assistant Executive Engineer MLCSD-III & IV MLCD Nohkum |
| 330 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift up to 1.5 m, as directed by Engineer-in-charge: In All kinds of soil. |
| 331 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In Mix proportion 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 332 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level: With Thermo Mechanically treated bar of grade FE-500D or more. |
| 333 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level: With Mild steel and Medium Tensile steel bars. |
| 334 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: In Mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 335 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In Mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 336 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: In Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 337 | Centering and shuttering including strutting, propping etc. and removal of form work for: In Columns, piers, abutments, pillars, posts and struts. |
| 338 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: In Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 339 | Providing 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand). |
| 340 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : With Two or more coats on new work. |
| 341 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 342 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : With Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 343 | RENOVATION OF THE SITE OFFICE OF THE ASSISTANT EXECUTIVE ENGINEER MLCSD-IV NOHKUM |
| 344 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 345 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up consolidating each deposited layer by ramming and watering, lead up 1to 50m and lift upto 1.5m. |
| 346 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 347 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In mix proportion 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal size. |
| 348 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 349 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: With Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 350 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(a) Foundation, footing, base of column, Pile cap, raft and mass concrete works etc. |
| 351 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(b) Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 352 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(c) Column, pillars, piers, abutments, posts & struts. |
| 353 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(d) Suspended floors, roofs, landings, balconies and access platform. |
| 354 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : In mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 355 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 356 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With modular bricks. |
| 357 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately): With Second class teak wood. |
| 358 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment): With Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 359 | Cement plaster of 20 mm thick of mix 1:4 (1 cement : 4 fine sand) |
| 360 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 361 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth: 50mm thick in proportion 1:4:8. |
| 362 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 363 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement @ 3.3 kg/sqm including pointing the joints with cement and matching pigments etc., complete. |
| 364 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately): Second class teak wood - 35 mm thick shutter. |
| 365 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : Size - 125x64x2.50 mm. |
| 366 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : Size - 250x10mm. |
| 367 | Providing and fixing bright finished brass handles with screws etc. Complete: Size - 125mm. |
| 368 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : Size - 9.75.2250x10x5mm. |
| 369 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 370 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: With White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 371 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: With White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. |
| 372 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 373 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge: With 15 mm nominal dia. |
| 374 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Medium size. |
| 375 | Providing and fixing Toilet paper Holder: Medium size. |
| 376 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour: 600mm Towel rail. |
| 377 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete with Flexible pipe - 40mm dia. |
| 378 | Providing and fixing soil, waste and vent pipes:(a) 100mm dia- Sand cast iron S&S pipe as per IS: 1729 |
| 379 | Providing and fixing soil, waste and vent pipes:(b) 75mm dia- Sand cast iron S&S pipe as per IS: 1729 |
| 380 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete(a) 100 mm dia- Sand cast iron S&S as per IS - 1729 |
| 381 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete(b) 75 mm dia- Sand cast iron S&S as per IS - 1729 |
| 382 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts andnuts complete: With 100x100x100mm - Sand cast iron S&S as per IS - 1729. |
| 383 | Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : With 100x100x75mm- Sand cast iron S&S as per IS - 1729. |
| 384 | Providing and fixing terminal guard : With 100mm Sand cast iron S&S as per IS - 1729. |
| 385 | Providing and fixing terminal guard : With 75mm - Sand cast iron S&S as per IS - 1729 PVC cowl of ISI make. |
| 386 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: With 100 mm inlet and 100 mm outlet- Sand cast iron S&S as per IS: 3989 |
| 387 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: With Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms. |
| 388 | Providing and fixing PTMT Bottle Trap for Wash basin and sink: Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. |
| 389 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : With Water thinnable cement primer. |
| 390 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm. |
| 391 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : With Two or more coats on new work |
| 392 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 393 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat). |
| 394 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : With Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture. |
| 395 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank: With 1000 litre capacity. |
| 396 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold-water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge: Internal works - exposed on wall with 20mm nominal outer dia Pipes. |
| 397 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold-water supply including all CPVC plain and brass threaded fitting. This includes jointing of pipes and fitting, with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. |
| 398 | Providing and fixing gun metal gate valve with CI wheel approved quality (screwed end): With 25 mm nominal bore. |
| 399 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931: With 15mm nominal bore. |
| 400 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms: With 15mm nominal bore. |
| 401 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: With 15mm nominal bore. |
| 402 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 403 | Dismantling roofing including ridges, hipes valleys and gutters etc. And stacking the materials within 50meters lead of: G.S. Sheet. |
| 404 | Demolishing wood work in frames, trusses, purlins, and rafters upto 10 meters span and 5 meters height including stacking the materials within 50 metres lead: Of sectional area 40 square centimeter and above. |
| 405 | Dismantling Door, Windows, Celestory windows (steel or wood) shutter including chawkat architrave, holdfast etc. complete and stacking within 50 metre lead: In an area 3 Square metres and below. |
| 406 | Demolishing cement concrete manually/ by mechanical means including disposal of materials within 50 metres lead as per direction of Engineer-in-charge : Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 407 | Demolishing dry brick pitching in floor, drain etc. including stacking of serviceable materials and disposal of unserviceable materials within 50: |
| 408 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. |
| 409 | Septic Tank for the Site Office Ofthe Assistant Executive Engineer MLCSD-IV (40 User) |
| 410 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In All kinds of soil. |
| 411 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In Mix proportion 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal size. |
| 412 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): With modular bricks. |
| 413 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: With Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 414 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: With Mild Steel and Medium Tensile steel bars. |
| 415 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(a) In Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 416 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(b) In Suspended floors, roofs, landings, balconies and access platform. Thickness of floors/slab upto 200 mm. |
| 417 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement: In Mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 418 | 20mm cement plaster of mix proportion 1:4 (1 cement : 4 fine sand) |
| 419 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In Mix proportion 1:2:4 (1 cement:2 coarse sand (Zone III) : 4 graded stone aggregate 20mm nominal size. |
| 420 | Providing and fixing soil, waste and vent pipes: With 100mm dia - Sand cast iron S&S pipe as per IS: 1729 |
| 421 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: With 100 mm dia - Sand cast iron S&S as per IS - 1729 |
| 422 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. |
| 423 | Internal Electrification for The Site Office Of The Assistant Executive Engineer MLCSD-IV Nohkum. |
| 424 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required, (Group C - Long point wiring up to 10.00m). |
| 425 | Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 426 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 427 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: With 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. |
| 428 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required: |
| 429 | (a)5/6 A switch |
| 430 | (b)15/16 A switch |
| 431 | (c)3 pin 5/6 A socket outlet |
| 432 | (d)6 pin 15/16 A socket outlet |
| 433 | (e)Bell push |
| 434 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(a)3 module (100mmx75mm) |
| 435 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(b)6 module (100mmx75mm) |
| 436 | Supplying and fixing brass batten/ angle holder including connection etc as required. |
| 437 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 438 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 439 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 440 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required: With 63A TP&N. |
| 441 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required: With 8 way (4 + 24), Double door. |
| 442 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: With Double pole. |
| 443 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required: With 63Amp. |
| 444 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 445 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 446 | Construction of Side Drain, Protection Wall and Cement Concrete Floor at The Site Office of The Assistant Executive Engineer MLCSD-III & IV, Nohkum and at the Site Office of the Executive Engineer MLCD Nohkum. |
| 447 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In All kind of soil. |
| 448 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 449 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: With Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 450 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(a) Foundation, footing, base of column, Pile cap, raft and mass concrete works etc. |
| 451 | Centering and shuttering including strutting, propping etc. and removal ofworks for:(b) Column, pillars, piers, abutments, posts & struts. |
| 452 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: In Mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 453 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : In Mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 454 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In Mix proportion 1:2:4 (1 cement:2 coarse sand (Zone III) : 4 graded stone aggregate 20mm nominal size. |
| 455 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With modular bricks. |
| 456 | 20mm cement plaster of mix proportion 1:4 (1 cement : 4 fine sand). |
| 457 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: With G.I. Pipes. |
| 458 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : With Water thinnable cement primer. |
| 459 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.(a) On steel work |
| 460 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.(a) On concrete work |
| 461 | Repairing of Cable Tray from Dam Control Room to all Power Pack House. |
| 462 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 463 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 464 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \"Reducer\" (galvanisation not less than 50 microns) with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. |
| 465 | 300 mm width X 50 mm depth X 1.6 mm thickness Plain cover (300mm) 600 mm width X 50 mm depth X 2.0 mm thickness |
| 466 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.1 feet (300mm) cable tray including fastener etc: 600 mm width X 50 mm depth X 2.0 mm thickness |
| 467 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required: 600 mm width X 50 mm depth X 2.0 mm thickness |
| 468 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness |
| 469 | CONSTRUCTION OF SECURITY SHED AT LEFT BANK OF MYNTDU LESHKA DAMSITE. |
| 470 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 471 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 472 | Steel reinforcement for R.C.C. work including straightening, cutting, bending placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 473 | Centering and shuttering including strutting, propping etc. and removal of form for.(a) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 474 | Centering and shuttering including strutting, propping etc. and removal of form for.(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 475 | Centering and shuttering including strutting, propping etc. and removal of form for.(c) Suspended floors, roofs, landings, balconies and access platform |
| 476 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 477 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 478 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 479 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 480 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 481 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 482 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 483 | EXTENSION OF D G SET CONTROL ROOM AT MYNTDU LESHKA DAM. |
| 484 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. In all kind of soil and ordinary rock. |
| 485 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: Mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 486 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 487 | Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundations, footings, bases of columns, etc. for mass concrete |
| 488 | Centering and shuttering including strutting, propping etc. and removal of form for:(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 489 | Centering and shuttering including strutting, propping etc. and removal of form for:(c) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 490 | Centering and shuttering including strutting, propping etc. and removal of form for:(d) Suspended floors, roofs, landings, balconies and access platform |
| 491 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Mix 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 492 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 493 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 494 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand :12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 495 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 496 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 497 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 498 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 499 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 500 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 501 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 502 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (medium point wiring up to 10m). |
| 503 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 504 | RENOVATION OF THE SITE OFFICE OF THE EXECUTIVE ENGINEER, MLCD-II NOHKUM. |
| 505 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In all kinds of soil. |
| 506 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up consolidating each deposited layer by ramming and watering, lead up 1to 50m and lift upto 1.5m. |
| 507 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 508 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:Mix 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal nsize. |
| 509 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 510 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 511 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 512 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild teel and Medium Tensile steel bars. |
| 513 | Centering and shuttering including strutting, propping etc. and removal ofworks for: Foundation, footing, base of column, Pile cap, raft and mass concrete works etc. |
| 514 | Centering and shuttering including strutting, propping etc. and removal ofworks for: Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 515 | Centering and shuttering including strutting, propping etc. and removal ofworks for: Column, pillars, piers, abutments, posts & struts. |
| 516 | Centering and shuttering including strutting, propping etc. and removal ofworks for: Suspended floors, roofs, landings, balconies and access platform. |
| 517 | Centering and shuttering including strutting, propping etc. and removal ofworks for: Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 518 | Centering and shuttering including strutting, propping etc. and removal ofworks for: Stairs, (excluding landings) except spiral-staircases. |
| 519 | Centering and shuttering including strutting, propping etc. and removal ofworks for: Weather shade, Chajjas, corbels etc., including edges. |
| 520 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :Mix 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 521 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 522 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 523 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size). |
| 524 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 525 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 526 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately): Second class teak wood. |
| 527 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 528 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 529 | 20mm cement plaster of mix.1:4 (1 cement : 4 fine sand) |
| 530 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 531 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement @ 3.3 kg/sqm including pointing the joints with cement and matching pigments etc., complete. |
| 532 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Makrana white second quality. |
| 533 | Extra for pre finished nosing to treads of steps of marble stone. |
| 534 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement: 18 mm thick. |
| 535 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 536 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately): Second class teak wood, 35 mm thick shutter. |
| 537 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete: Size- 125x64x2.50 mm |
| 538 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : Size- 250x10mm. |
| 539 | Providing and fixing bright finished brass handles with screws etc. complete: Size- 150mm. |
| 540 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : Size- 250x10x5mm. |
| 541 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 542 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 543 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Staircase - (SS pipe 65mm OD and 2.11 wall thickness @ 3.75kg/m) |
| 544 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. |
| 545 | Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm. |
| 546 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 547 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 548 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat). |
| 549 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 550 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 551 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20mm nominal outer dia Pipes. |
| 552 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fitting. This includes jointing of pipes and fitting, with one step CPVC solvent cement, trnching, refilling & testing of joints complete as per direction of Engineer in charge: 25mm nominal outer dia. |
| 553 | Supplying and fixing gun metal gate valvwith CI wheel approved quality (screw end): 5 mm nominal bore. |
| 554 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15mm nominal bore. |
| 555 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore. |
| 556 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 557 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design make and mosquito proof coupling of approved municipal design making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. |
| 558 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 559 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 560 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. |
| 561 | Providing and fixing Toilet paper Holder |
| 562 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 563 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 564 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 565 | Septic Tank for 40 User |
| 566 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil. |
| 567 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:Mix 1:3:6 (1 cement:3 coarse sand (Zone III) : 6 graded stone aggregate 20mm nominal nsize. |
| 568 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) :With modular bricks. |
| 569 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 570 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Mild teel and Medium Tensile steel bars. |
| 571 | Centering and shuttering including strutting, propping etc. and removal of works for: Lintels, beams, plinth beams, girders, bressumers and cantilever. |
| 572 | Centering and shuttering including strutting, propping etc. and removal ofworks for:Suspended floors, roofs, landings, balconies and access platform. |
| 573 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with mix1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 574 | 20mm cement plaster of mix. 1:4 (1 cement : 4 fine sand) |
| 575 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:Mix 1:2:4 (1 cement:2 coarse sand (Zone III) : 4 graded stone aggregate 20mm nominal nsize. |
| 576 | Providing and fixing soil, waste and vent pipes : 100 mm dia- Sand cast iron S&S pipe as per IS: 1729. |
| 577 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 mm dia- Sand cast iron S&S as per IS – 1729. |
| 578 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 579 | Internal Electrification Wiring for Renovation of The Site Office of The Executive Engineer, MLCD Nohkum |
| 580 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (long point wiring). |
| 581 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 582 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 583 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 584 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 585 | (a) 5/6 A switch |
| 586 | (b) 15/16 A switch |
| 587 | (c) 3 pin 5/6 A socket outlet |
| 588 | (d) 6 pin 15/16 A socket outlet |
| 589 | (e) Bell push |
| 590 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(a) 3 module (100mmx75mm) |
| 591 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.(b) 6 module (100mmx75mm) |
| 592 | Supplying and fixing brass batten/ angle holder including connection etc as required. |
| 593 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 594 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 595 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required: 510mm sweep |
| 596 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required:63A TP&N |
| 597 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required:8 way (4 + 24), Double door |
| 598 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:Double pole |
| 599 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required:63Amp |
| 600 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 601 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 602 | Boundary Fencing at the Office Of the Executive Engineer MLCD Nohkum |
| 603 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge:All kinds of soil. |
| 604 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: Mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 605 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo Mechanically treated bar of grade FE-500D or more. |
| 606 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete: Mild steel and Medium Tensile steel bars. |
| 607 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Mix 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 608 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 609 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 610 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, piers, abutments, pillars, posts and struts. |
| 611 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor five level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 612 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 613 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 614 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete: On steel work. |
| 615 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 616 | Watch Tower on the Left Bankof Myntdu Leshka Dam Site |
| 617 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 618 | Providing brick soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete stone soling of thickness 100mm |
| 619 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 620 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete(a) Thermo-Mechanically Treated (TMT) bar of FE-500D or more. |
| 621 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete(b) Mild steel and Medium Tensile steel bars. |
| 622 | Centering and shuttering including strutting, propping etc. and removal of form for :(a) Foundations, footings, bases of columns, etc. for mass concrete |
| 623 | Centering and shuttering including strutting, propping etc. and removal of form for(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 624 | Centering and shuttering including strutting, propping etc. and removal of form for(c) Columns, Pillars, Posts & Strut |
| 625 | Centering and shuttering including strutting, propping etc. and removal of form for(d) Suspended floors, roofs, landings, balconies and access platform |
| 626 | Centering and shuttering including strutting, propping etc. and removal of form for (e) Stairs, (excluding landings) except spiral-staircases |
| 627 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 628 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Mix 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources). |
| 629 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size) |
| 630 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 631 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.G.I. pipes |
| 632 | 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 633 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 634 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 635 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 636 | Watch Tower on the Right Bankof Myntdu Leshka Dam Site |
| 637 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 638 | Providing brick/stone soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: With stone soling of thickness 100mm. |
| 639 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel : Mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 640 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (a) Thermo Mechanically Treated bar of FE- 500D or more. |
| 641 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.(b) Mild steel and Medium Tensile steel bars. |
| 642 | Centering and shuttering including strutting, propping etc. and removal of form for :(a) Foundations, footings, bases of columns, etc. for mass concrete |
| 643 | Centering and shuttering including strutting, propping etc. and removal of form for :(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 644 | Centering and shuttering including strutting, propping etc. and removal of form for :(c) Columns, Pillars, Posts & Strut. |
| 645 | Centering and shuttering including strutting, propping etc. and removal of form for :(d) Suspended floors, roofs, landings, balconies and access platform |
| 646 | Centering and shuttering including strutting, propping etc. and removal of form for :(e) Stairs, (excluding landings) except spiral-staircases |
| 647 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 648 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Mix 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 649 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 650 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor five level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 651 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: G.I. pipes (48.3mm dia). |
| 652 | 20 mm cement plaster of mix 1:4 (1 cement: 4 fine sand). |
| 653 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 654 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. |
| 655 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 656 | CONSTRUCTION OF ROOF COVERING FOR250KVA D.G SET WITH PROTECTION RAILING. |
| 657 | Demolishing plain cement concrete including stacking of steel bars and disposal of unserviceable material as directed for all levels. |
| 658 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 659 | Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m. All kinds of soil |
| 660 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Mix 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 661 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Mix 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 662 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 663 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 664 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts. (i) Square, Rectangular, Polygonal in plan or any shape like tee/L etc. having plane vertical face |
| 665 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 666 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 667 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil. |
| 668 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 669 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 670 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 671 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required: 1.00 mm thick with zinc coating not less than 275 gm/m². |
| 672 | CONSTRUCTION OF FOUNDATION AND INSTALLATION OF HIGH MAST LIGHTING TOWER 15 M HEIGHT ON BOTH SIDES AT MYNTDU LESHKA CONCRETE DAM |
| 673 | Supply with Transportation to site of 15-metre-High Mast with its accessories Mast shaft shall be in three section, made from HT steel grade BSEN 10025, S335JO hot dip Galvanised and suitable for wind speed as per IS 875, with raising lowering. It should also include accessories for High Mast inc. head frame steel wire rope (Grade AISI 316, tailing cable, double drum winch galvanised lantern carriage arrangement suitable for 12 Luminaries symmetrically and its control gear box, motor, manual operating handle, motor mounting plate, L stapler, Lightening arrester, Junction Box, Lightening finia, Luminaries wiring material, MCB in base compartment completely etc. Specification: Height :- 15 metre in 3 sections: PCD = 460 mm (approx):Bottom diameter = 300mm(approx),Top Diameter = 150mm (Approx):Bottom Thickness = 4mm, Top Thickness = 3mm:Base Plate Diameter = 560mm, Thickness = 25mm:Door Size Opening Bottom = (1200 X 300 ) mm:Foundation hole diameter,bolt sizes(Diameter and Length):Wire rope = 6mm (7/9 construction):Method of Operation = Manual and Motorised( RIGHT AND LEFT BANK) |
| 674 | Supply of suitable galvanised foundation bolts manufactured from special steel along with nuts, washers, anchor & Templates Specifications:Foundation Bolt Diameter= 25 mm ,Foundation Bolt Length= 1200 mm, Nos of Foundation Bolt= 12 Nos |
| 675 | Supply of complete LED Flood Light of ( 200 W each set) with 5 years warranty period (Crompton/Bajaj/Havels) |
| 676 | Supply of twin dome aviation obstruction lights of type (Crompton/Bajaj/Havels). |
| 677 | Supply of control panel housing having suitable control circuit for automatic, timely ON/OFF operation of the mast. It shall also consist of suitable control for the power tool motor completely. |
| 678 | Supplying, Erection, Testing and Commissioning of Earthing station with 50 mm dia. GI pipes 3.65 mm thick, 3M long and 1no. 4 SWG G.I wire 4 M long, 13mm dia, 80 mm long G.I bolt double washers, nuts, S&F 15 mm dia G.I pipe protection, to be field with bitumen, partly underground and partly above above ground level driven to an avarage depth 3.65 m below the ground level including excavation of soil. |
| 679 | Supplying and fixing double door MS feeder piller box with near the high mast with 63A, 450 TPN Main Switch on iron frame on wall and making connection ( standard make) |
| 680 | S&F 63A Kit Kat Fuse on wooden board |
| 681 | Supply and fixing of 900 X 600 X 300 mm Meter Box of minimum 1.6 mm G.I sheet with weather and dust proof, outdoor type having top canopy, sides having Louvers for ventilation, double door,locking arrangement, four legs of the meter box (G.I. flat50x6x150mm) with 63 Amp, 220 volt, SP MCB-3nos. for isolation purpose & necessary assembling. |
| 682 | Erection, Testing and Commissioning of 15 Mtr High Mast System inc. all accessories completely. |
| 683 | Supplying and Drawing 4 core 35 sqm pvc insulated and scheated alluminium conductor armoured cable through underground |
| 684 | Foundation: |
| 685 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge. All kinds of soil. |
| 686 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level:Thermo Mechanically Treated bar of FE-500D or more. |
| 687 | Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns, etc. for mass concrete. |
| 688 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 689 | Left Bank |
| 690 | Supply of suitable galvanised foundation bolts manufactured from special steel along with nuts, washers, anchor & Templates Specifications: Foundation Bolt Diameter= 25 mm , Foundation Bolt Length = 1200 mm,Nos of Foundation Bolt = 12 Nos |
| 691 | Supply of complete LED Flood Light of ( 200 W each set) with 5 years waranty period (Crompton/Bajaj/Havels). |
| 692 | Supply of twin dome aviation obstruction lights of type (Crompton/Bajaj/Havels). |
| 693 | Supply of control panel housing having suitable control circuit for automatic, timely ON/OFF operation of the mast. It shall also consist of suitable control for the power tool motor completely. |
| 694 | Supplying, Erection, Testing and Commissioning of Earthing station with 50 mm dia. GI pipes 3.65 mm thick, 3M long and 1no. 4 SWG G.I wire 4 M long, 13mm dia, 80 mm long G.I bolt double washers, nuts, S&F 15 mm dia G.I pipe protection , to be field with bitumen, partly underground and partly above above ground level driven to an average depth 3.65 m below the ground level including excavation of soil. |
| 695 | Supplying and fixing double door MS feeder piller box with near the high mast with 63A, 450 TPN Main Switch on iron frame on wall and making connection (standard make). |
| 696 | S&F 63A Kit Kat Fuse on wooden board. |
| 697 | Supply and fixing of 900 X 600 X 300 mm Meter Box of minimum 1.6 mm G.I sheet with weather and dust proof, outdoor type having top canopy, sides having Louvers for ventilation, double door,locking arrangement, four legs of the meter box (G.I. flat50x6x150locking arrangement, four legs of the meter box (G.I. flat 50x6x150mm) with 63 Amp, 220 volt, SP MCB-3nos. for isolation purpose & necessary assembling. |
| 698 | Erection, Testing and Commissioning of 15 Mtr High Mast System inc. all accessories completely. |
| 699 | Supplying and Drawing 4 core 35 sqm pvc insulated and scheated alluminium conductor armoured cable through underground. |
| 700 | Foundation: |
| 701 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil. |
| 702 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bar of FE-500D or more |
| 703 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. |
| 704 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 705 | EXTENSION THE HEIGHT OF CABLE TRENCH FROM D.G SET TO DAM CONTROL ROOM UPTO POWER INTAKE. |
| 706 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
| 707 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: Mix 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size). |
| 708 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge: Upto and including 12mm dia. |
| 709 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Mix 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 710 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 711 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 712 | Centering and shuttering including strutting, propping etc. and removal of form: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 713 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Mix 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 714 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With Modular bricks. |
| 715 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand). |
| 716 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. |
| 717 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 718 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 719 | PROVIDING RCC PEDESTAL FOR DG SET 320KVA DG SET. |
| 720 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 721 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts:Square, Rectangular, Polygonal in plan or any shape like tee/L etc. having plane vertical face |
| 722 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Mix 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 723 | PAINTING OF ROOF COVERING OF DG SET 320 KVA AND PROTECTION RAILING |
| 724 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m². |
| 725 | Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter for chimney stacks, sky light etc.:1.00 mm thick |
| 726 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.:0.80 mm thick with zinc coating not less than 275 gm/m² |
| 727 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete: On steel work |
| 728 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete: On concrete work. |
| 729 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete: On steel work |
| 730 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete: On concrete work. |
| 731 | METALLING INCLUDING BLACK TOPPING OF A ROAD ALONG THE PDENGSHAKAP DAMSITE OF MLHEP CH: 0.00 -11.00 KM |
| 732 | Scarifying metalled (water-bound) road surface including disposal of rubbish, lead upto 50 m and consolidation of the aggregate received from scarifying with power road roller of 8 to 10 tonne capacity. |
| 733 | Supplyimg and stacking at site: (including transportation from quarry up to worksite):53 mm to 22.4 mm size stone aggregate. |
| 734 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 735 | Supplying and stacking at site: (including transportation from quarry up to worksite):Stone screening 13.2 mm nominal size (Type A) |
| 736 | Supplying and stacking at site: (including transportation from quarry up to worksite):Red bajri |
| 737 | Supplying and stacking at site: (including transportation from quarry up to worksite):Moorum |
| 738 | Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications: On W.B.M. @ 0.75 Kg / sqm. |
| 739 | 2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. |
| 740 | Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180-micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. |
| 741 | Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS:164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete:New work (Two or more coats) (3 lines-125mm wide). |
| 742 | METALLING INCLUDING BLACK TOPPING AT INSPECTION BUNGALOW OF MLHEP CH: 0.00-150.00 M |
| 743 | Scarifying metalled (water-bound) road surface including disposal of rubbish, lead upto 50 m and consolidation of the aggregate received from scarifying with power road roller of 8 to 10 tonne capacity. |
| 744 | Supplying and stacking at site: (including transportation from quarry up to worksite):53 mm to 22.4 mm size stone aggregate |
| 745 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 746 | Supplying and stacking at site: (including transportation from quarry up to worksite):Stone screening 13.2 mm nominal size (Type A). |
| 747 | Supplying and stacking at site: (including transportation from quarry up to worksite):Red bajri. |
| 748 | Supplying and stacking at site: (including transportation from quarry up to worksite):Moorum. |
| 749 | Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications: On W.B.M. @ 0.75 Kg / sqm |
| 750 | 2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately).With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. |
| 751 | Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180-micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt. |
| 752 | Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS:164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete:New work (Two or more coats) (3 lines-125mm wide). |
| 753 | CONSTRUCTION OF STEPPED BREAST WALL TO PREVENT THE EROSION AT CH: 9.45 KM - CH: 9.95 KM OF ROAD FROM PDENGSHAKAP TO DAMSITE OF MLHEP |
| 754 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge: In all kinds of soil. |
| 755 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and: In mix proportion 1:3:6 (1 Cement: 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 756 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: In Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 757 | Pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand): With Flush/ Ruled pointing. |
| 758 | 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand) |
| 759 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 760 | CONSTRUCTION OF STEPPED RETAINING WALL TO PREVENT SOIL EROSION AT CH: 10.40 KM - CH: 10.70 KM OF ROAD FROM PDENGSHAKAP TO DAMSITE OF MLHEP |
| 761 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge: In all kinds of soil. |
| 762 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering: In Mix proportion 1:3:6 (1 Cement: 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 763 | Coursed rubble masonry (first sort) with hard stone in foundation and plinth with: In Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 764 | Pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand): With Flush/ Ruled pointing. |
| 765 | 12 mm cement plaster of mix: 13.1.1 1:4 (1 cement: 4 fine sand) |
| 766 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 767 | CONSTRUCTION OF CATCH WATER DRAIN AT CH: 9.50 KM - 9.90 KM OF ROAD FROM PDENGSHAKAP TO DAMSITE OF MLHEP. |
| 768 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 120 m and lift upto 1.5 m, as directed by Engineer-in- Charge:In all kinds of soil. |
| 769 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering: In mix proportion 1:3:6 (1 Cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size). |
| 770 | Centering and shuttering including strutting, propping etc. and removal of form work for: In Foundations, footings, bases for columns. |
| 771 | 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand) |
| 772 | CONSTRUCTION OF P.C.C SIDE DRAIN ALONG THE PDENGSHAKAP DAMSITE ROAD OF MYNTDU LESHKA H.E. PROJECT IN WEST JAINTIA HILLS DISTRICT |
| 773 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil |
| 774 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In mix 1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 775 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns. |
| 776 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand). |
| 777 | 1. All amounts shall be in Rupees.2. Use separate columns for each type of taxes. Other taxes means entry tax, octroi, exit tax or any other taxes as applicable. |