noida metro rail corporation limited has published Supply, Installation, Testing And Commissioning Of Fire Alarm Systems And Servicing, Repairs & Replacement Of Spare Parts Of Installed Fire Alarm System, Fire Fightingand Other Domestic Water Pumps Inculding Dg Sets Installedat Nmrc Head Office, . Submission Date for this Tender is 13-03-2024. Alarm Systems Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Firefightingand other domestic water pumps installedat NMRC head office ( Diesel Pump, Main Hydrant pump, jockey pump and other pumps are present) |
2 | Main Hydrant Pump |
3 | Servicing, Repairs & replacement of spare parts in Vertical Centrifugal Pumps of Kirloskar Brothers Ltd., make pump capacity 137 M3/Hr at the head of 70 Meters, 1450 RPMcomplete with 45 KW 3 Phase Induction, 1480 RPM Motor suitable for operation on 415 Volt 50 Hz. AC complete etc as required for following items of work without panel: |
4 | Dismentalling the pump from foundation after disconnection from WPP, suction and discharge plumbing work, shifting to workshop, re-assembling after servicing / repair in workshop and re-installation on foundation, re-connection of suction & discharge plumbing work, Electrical Connections with WPP, testing & commissioning at site complete etc as required. |
5 | Rewinding of Motor with copper winding wire with F class insulation after removing burnt copper wires complete etc as required (Rates considering the salwage value of old dismantalled copper wire which shall be retained by the contractor, rates will be consider after all scrap less) |
6 | Overhauling of Pump with replacement of all standard spare like as ball bearings complete, SS Impeller, Diffuser, Shaft, TC bush,Mechanical Seal etc as required |
7 | Diesel Engine driven Pumps |
8 | Servicing, Repairs & replacement of spare parts in g of Diesel Engine driven Pump Dewatering non-clog Sump Pumps of Kirloskar Brothers Ltd. make capacity appx. 137 M3/Hr at the head of 178 Meters complete withKW/HP61/83 3 Phase complete etc as required for following items of work without Panel: |
9 | Dismentalling the pump from foundation after disconnection from WPP, suction and discharge plumbing work, shifting to workshop, re-assembling after servicing / repair in workshop and re-installation on foundation, re-connection of suction & discharge plumbing work, testing & commissioning at site complete etc as required. |
10 | Servicing /B check of Diesel engine of standby fire pump as per scope of work (Once in 06 months) |
11 | Supply and fitting of Battery 12 V, suitablefor Diesel Engine driven fire pump (Make Kirloskar,BHP-133,RPM-1800) of standby fire pump. |
12 | Jockey Pump |
13 | Servicing, Repairs & replacement of spare parts in Vertical Centrifugal Dewatering non-clog Sump Pumps of Kirloskar Brothers Ltd. make capacity appx. 10 M3/Hr at the head of 80 Meters complete with 5.5 HP / 4 KW 3 Phase, Submersible Induction Motor suitable for operation on 415 Volt 50 Hz. AC complete etc as required for following items of work without Panel: |
14 | Dismentalling the pump from foundation after disconnection from WPP, suction and discharge plumbing work, shifting to workshop, re-assembling after servicing / repair in workshop and re-installation on foundation, re-connection of suction & discharge plumbing work, testing & commissioning at site complete etc as required. |
15 | Rewinding of Motor with copper winding wire along with F class insulation after removing burnt copper wires complete etc as required (Rates considering the salwage value of old dismantalled copper wire which shall be retained by the contractor after less old scrap) |
16 | Overhauling of Pump with replacement of standard spare like ball bearings complete Mechanical Seal, O ring kit + Oil, Shaft, impeller etc as per required. |
17 | fault visit, Servicing, Repairs & replacement of spare parts inof Booster Pump 1.0HP with 24Ltr Tank except winding |
18 | Rewinding of1.0HP with 24Ltr Motor with copper winding wire after removing burnt copper wires complete etc. as required (Rates considering the salwage value of old dismantalled copper wire which shall be retained by the contractor after old scrap less) |
19 | Servicing, Repairs & replacement of spare parts inof 5 HP, 3 Phase Submersible pump, complete in all respect |
20 | Rewinding of5 HP, 3 Phase Submersible pump with copper winding wire after removing burnt copper wires complete etc. as required (Rates considering the salwage value of old dismantalled copper wire which shall be retained by the contractor after old scrap less) |
21 | Supply, installation, testing and commissioning of 1 HP Sump Pum, complete in all respect |
22 | Painting of external Hydrants &Hydrant post, Valves, MS Fire Water Line, External and internal fire hydrant system, FHC ddor, two coats of red oxide primer uniformly applied and two coats of oil paint applied thereafter. All pipes supports shall be painted black as specified for support & clamps.. |
23 | Check performance of Air vessel including Air Release Valve (Each) of Hydrant System. |
24 | Checking and Maintenance of Isolation Valve of size 2” to 4” (Gate type, Butterfly type, Ball type)/NRV’s. |
25 | Checking and Maintenance of Isolation Valve of size 6” to 8” (Gate type or Butterfly type)/NRV’S |
26 | Supply and installation of Butter fly handle suitable to existing valve |
27 | Hydro-testing of fire extinguisher (as and when required) 4 kg/5kg/6 Kg cap. |
28 | Refilling of ABC Stored pressure type Fire Extinguishers 4.5 Kg capacity |
29 | Hydro-testing of CO2 type Fire Extinguishers upto 6 kg capacity. |
30 | Supply and fitting of Glass for Door of Cabinet (Big) for Hydrant System including supply of rubber bidding. It shall be safe proof. It shall have size approx. 440mm x 1240mm. It shall be similar to existing one |
31 | Supply and replace the body sticker of Fire Extinguisher containing information about type of extinguisher, suitable on class of fire, picture method of operation of extinguisher, safety precautions. |
32 | Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MSplate with Air releasevalve with stop cock, flanged inlet connection anddrain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968. (The cushion tank should be suitable for rated working pressure.(Make: SafeFire, Radiant, East West) |
33 | Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required. |
34 | SUBHEAD: II: Hydrants, Sprinkler,Piping & Accessories |
35 | Supplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all victaulic fittings e.g. elbows,reducers, clamps, hangers, flanges, gaskets, nuts, bolts andwashers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick orRCC walls/slabs and making good the same etc. complete in all respect as required. (Make: Tata , Radiant , Jindal) |
36 | 100 mm dia |
37 | 80 mm dia |
38 | 32 mm dia |
39 | 25 mm dia |
40 | Providing and fixing forged brassball valve with forged brass ball (suitable for test pressure ofnot less than 15 kg / sq.cm of thefollowingsize :(Make: Zoloto, AIP, Sant) (Cost shall be inclusive of providing necessary union / flange connection). 25 mm dia |
41 | Providing & fixing of butterfly valve (suitable for test pressure of 15 kg / sqm) with flanges, nut bolts, gaskets and necessary pad locking arrangementcomplete required. (Make: Zoloto, AIP, Sant) |
42 | 80 mm dia |
43 | 100 mm dia |
44 | Providing & fixing swinging type First Aid hose reel in red colour drum with 30 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia globevalve stop cock, terminating with G.M.coupling&nozzleof 6mm outlet with shut off valve confirming to IS 8090 - 1976complete withMS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nutsconformingtoIS:884-1969 completeas required.(Make: Radiant, East West,Padmani, Zoloto) |
45 | Providing & fixing non-percolating rubber reinforced lined fire hose pipe (as per IS : 636) of 63 mm dia and length as described below. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked S.S male & femalecoupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire (Location : Internal fire hydrant) 15 m length (Make: Radiant, East West,Padmani,) |
46 | Providingand Fixing63 mm dia instantaneouspattern branchshort Stainless Steelpipe,20 mmdia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.(Make: Radiant,Padmani,kartar,) |
47 | Providingandfixing standard fire man"s axe with heavy rubber handle.(Make: Radiant, East West,Padmani) |
48 | Providing and fixing 5 mm thick glass door (with M.S. frame) of size 2.1 m x 1.2 m with center opening for fire hose cabinet. Suitably marked on the outside with the letters "FIRE HOSE" including locking arrangement. All M.S. work to be in Red P.O. colour over appropriate primer.The above item is only for masonary fire station.(Make: Radiant, East West,Padmani) |
49 | Providing and fixing flexible connectors consisting of flexible core 1.5 mtr. in lenghth of corrugated stainless steel tubing under the braid, (Braiding to be SS-304, tubing to be SS-304) for minimum working pressure rating of 200 PSI to be installed at connections from branch pipes to pendant sprinklers blow false ceiling as per specification of the manufacturers. (Make: Radiant, East West,Padmani) |
50 | Providing and Fixing 15 mm dia gunmetal / brass quartzoid type Sprinkler Head with quartz bulb and set to operate at specified temperature.(Make:East West,Padmani) Pendant Type,68° C, Chrome plated |
51 | SUBHEAD: III: Portable Chemical Fire Extinguishers |
52 | Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). ISI marked (IS:940) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in allrespectsincluding initial fill and wall suspension brackets(Make: East West,Padmani) |
53 | Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner).ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg.Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a fillingrateofnot more than 0.667 andwall suspension bracket.(Make: East West,Padmani) |
54 | Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). ISI marked (IS:2171) Portable Dry Chemical Power Type Fire Extinguisher with Gun Metal cap and nozzle and complete in all respects including initial fill and wall suspension bracket(Make: East West,Padmani) |
55 | Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white insideand red outsideandblackon the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.(Make: East West,Padmani) |
56 | Fire Alarm Work |
57 | PHOTOTHERMAL (MULTITECH) DETECTOR Supply, Installation, Testing & Commissioning, Installation of UL listed Intelligent Addressable MultiCriteria smoke cum Heat detector, optical type with blinking LED and standard base, being capable of being addressed electronically. Manual Addressing not acceptable. complete with base etc. as required. Approved Make:-Notifier/Ansul/Edwards |
58 | MANUAL CALL POINTSupply, Installation, Testing & Commissioning of UL Listed Intelligent Addressable Double action manual pull station, capable of being addressed electronically complete etc.as required.Approved Make:-Notifier/Edwards/Ansul |
59 | FAULT ISOLATOR Supply, Installation, Testing & Commissioning of UL Listed Addressable Fault Isolator module complete which detects short circuit and seperates the segment, complete etc. as required.and as per specifications.Approved Make:-Notifier/Ansul/Edwards |
60 | CONTROL MODULESSupply Installation, Testing & Commissioningof UL Listed Addressable control module (MCP) complete as required for switching ON of smoke extraction fans / PressurisationFans etc. andswitching off AHU" s, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, complete as required.and as per specifications. Sprinkler flow switches. Approved Make:-Notifier/Ansul/Edwards |
61 | Supply, Installation, Testing & Commissioning of MONITOR MODULES UL Listed Addressable Monitor module complete as required for monitoring flow switches/ interface with any third party equipment capable of being addressed electronically etc. completeas required and as per specifications Hooters Circuit.Approved Make:-Notifier/Ansul/Edwards |
62 | Suppluing abd Installation , of exit signs: photo luminescent safety signage made up of photo luminescent material of rare earth aluminates, non radioactive working. |
63 | Supply, Installation, Testing & Commissioning of PVC Insulated 2 x 1.5 sq mm FRLS copper conductorArmoured cable with termination on each end with ferrules .Approved Make:-Polycab/Customized/Parashield |
64 | Response Indicator.Approved Make:-Notifier/Edwards/Ansul |
65 | Supply, installing, testing and commissioning of UL Listed Addressable Rate of Rise Heat Detector rated at 9.4 deg C/min. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Approved Make:-Notifier/Edwards/Ansul |
66 | Supply, Installation, Testing and Commissioning of UL Listed Fire Alarm Hooter (sound output of minimum 90 dB upto a distance of 30 meters) cum Strobe (Selectable 15, 30, 75, or 110 cd), made Addressable with the help of Intelligent Addressable Signal Module (cost of the Module to be included), capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable, with seperate power supply arrangement complete as required. Approved Make:-Notifier/Ansul/Edwards |
67 | Supply, installing, testing and commissioning ofUL Listed 2W/6W Ceiling Mounted speaker with capacity to have 1/4,1/2,1 and 2 watt tapping, working at 83dB compatible with amplifier complete as required. Approved Make:-Honeywell/Bosch/Ateis |
68 | Comprehensive Annual maintenance of one PA and paging system complete circuit wiringand other associated components complete etc as required excluding speakers . ) installed at NMRC head office, sector-29, Noida. |
69 | Repair and Annual maintenance contract (AMC) for 125 KVA, 160 KVA, and 180 KVADiesel engines installed at NMRC head office, sector-29, Noida. |
70 | 125 KVA kirloskarDG SET (6R1080TA) |
71 | Supply and installation of 125 KVA kirloskarDG Fuel filter 1.1 Ltr. |
72 | Supply and installation of 125 KVA kirloskar DG AIR FILTER |
73 | Supply and installation of 125 KVA kirloskar DG fuel tank hose pipe with clamp, liko pipe, copper washer (13 No.)-14 qty. |
74 | Supply and fixing of 8 mm dia fuel PVC pipe with two side clip |
75 | Supply of Coolant and fill the coolatnt tank of 125 KVA kirloskar DG as per recommended |
76 | Supply and installation of Kirloshker Engine Oil |
77 | Supply and installation of EMS panel suitable for 125 KVA kirloskar DG with display, supporting, covering,etc. complete as per direction of E/I |
78 | Supply and fixing of long size fuel pipe of 125 KVA kirloskar DG on filter with copper washer |
79 | Supply and fixing of fuel sensor |
80 | Supply and fixing of releif valve of 125 KVA kirloskar DG as per E/I |
81 | Supply and installation of radiator Cap. |
82 | Dismelting, cleaning and resinstallation of 125 KVA kirloskar DG radiator . |
83 | Supply and fixing of Coolant sensor, switch |
84 | Supply and fixing of suitable size of alaternator output cover |
85 | Supply and fixing of Emergency switch |
86 | Supply and fixing of canopy lamp |
87 | Supply and fixing of suitable size of fuel tank cap having lock arrangement |
88 | Supply and fixing of suitable air filter service indicator |
89 | Supply and fixing of exhaust pipe silencer suitable for installed 125 KVA kirloskar DG |
90 | Supply and fixing of Oil supply hose with copper washer (size-14 no.)- qty-4 |
91 | Spray paint of canopy, base etc. as per direction of E/I |
92 | D-check Complete DG set should be dismental. |
93 | Turbo charger service |
94 | Injector Pin service |
95 | Cylinder Head service |
96 | PT Pump sevice |
97 | Change Piston Bearing, |
98 | Change nozels, |
99 | Piston Cylinderchange |
100 | Change Canopy filter |
101 | 180 KVA CUMMINS DG SET (QSB5.9-G2) |
102 | Supply of Engine oil |
103 | Supply and installation of Fuel filter suitable for 180 KVA CUMMINS DG set |
104 | Supply and installation of Oil filter suitable for 180 KVA CUMMINS DG set |
105 | Dismelting, cleaning and resinstallation of 180 KVA CUMMINS DG radiator |
106 | Supply of Coolant |
107 | Supply and installation of priamary air filter |
108 | Supply and installation of air safety filter |
109 | Supply and installation of 12 mm fuel pipe with hose clamp |
110 | Supply and installation of 4 mm PVC pipe for Diesel tank with clip |
111 | Supply and installation of steel/rubber fuel level indiciator for external Diesel tank of 990 Ltr. |
112 | 160 KVA KOEL DG Set (6K1080TAG2) |
113 | Supply and fixing of oil filter suitable for 160 KVA KOEL DG Set |
114 | Supply and fixing of bypass filter suitable for 160 KVA KOEL DG Set |
115 | Supply and fixing of diesel primary filter suitable for 160 KVA KOEL DG Set |
116 | Supply and fixing of diesel secondary filter suitable for 160 KVA KOEL DG Set |
117 | Supply and fixing of water seperator suitable for 160 KVA KOEL DG Set |
118 | Supply of Kirloshker primium oil |
119 | Dismetling, cleaning and reinstallation of radiator 160 KVA KOEL DG Set |
120 | Supply of Koel coolant |
121 | Supply and installation of air filter |
122 | Claeaning and use Spary paint to base of 160 KVA KOEL DG Set |
123 | Supply of 0.75 HP liquid ring pump for diesel fuel from tank to DG tank with inlet armoured pipe connection ended with proper termination |
124 | Supply and fixing of pump Fuel Transfer Pipe for Diesel Oiland water with pump |
125 | Annual maintenance contarct of 125 KVA Kirloskar DG set with04 Visit Plan With B Check Kit for 1st year |
126 | Annual maintenance contarct with 180 KVACUMMINS DG set Carried out two B Check and unlimited visit in fault condition for 1st year |
127 | Annual maintenance contarct with 160 KVA KOELDG SET Carried out two B Check and unlimited visit in fault condition for 1st year |
128 | Supply, installing, testing and commissioning of Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 300 analog addressable devices. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be complete with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits with adequate zone control and accessories. The system shall be equipped with necessary Digital Audio Amplifier capable of processing one of 8 audio channels and amplifiers as per the speakers requirement at 70.7 VRMS output along with necessary enclosures. The DAA shall be fully monitored for fault and alarm reporting. The proposed Digital Amplifiers shall not be rail mounted / dependant on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation.The Digital Amplifier Loop shall have N+1 Redundancy concept to avoid chances of failure. The Fire Fighters Telephone System shall be capable of having minimum 35 Telephones on conference with inbuild High Speed Network Card, also having printing option of data |
129 | Any DSR item not mentioned in this BOQ, DSR- 2019 and later on related to fire alarm and fire hydrant work on measurement basis, Rate will be considered as per latest CPWD publication |