Tender For Lan Cctv And Fire Alarm System Work In Construction Of Phase-2 Of Medical College And Upgradation Of Hospital At Alwar Rajasthan, Jaipur-Rajasthan

Rajasthan State Road Development And Construction Corporation Limited has published Tender For Lan Cctv And Fire Alarm System Work In Construction Of Phase-2 Of Medical College And Upgradation Of Hospital At Alwar Rajasthan. Submission Date for this Tender is 12-03-2024. Alarm Systems Tenders in Jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42426912
Tender For Lan Cctv And Fire Alarm System Work In Construction Of Phase-2 Of Medical College And Upgradation Of Hospital At Alwar Rajasthan
Open Tender
Indian
Rajasthan
Jaipur
12-03-2024

Tender Details

Tender For Lan Cctv And Fire Alarm System Work In Construction Of Phase-2 Of Medical College And Upgradation Of Hospital At Alwar Rajasthan

Key Value

Document Fees
INR 2360 /-
EMD
INR 684000.0 /-
Tender Value
INR 3.42 Crore /-

BOQ Items

Name of Work : - LAN CCTV and Fire Alarm System work in Construction of Phase-II of Medical college & Upgradation of Hospital at Alwar, Rajasthan
Sl. No. Item Description
1PWD Electrical BSR 2022
2S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
320 mm
425 mm
532 mm
6Providing & Fixing of ISO certified company made virgin material PVC trunking systemas per PWD specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall haveadaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM shall have submitNABL accrediated /CPET lab test reportsbefore execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
732mm X 20mm
8100/105mm x 50mm
9Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
10Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
11Cat 6, Un-sheilded Information Outlet
12Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
13Single Aperture
14Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
151-2 Module
16Supply, Installation, Testing and Comissioning of Rack mounted 19" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
17Modular Patch Panel Loaded with Cat -6 I/O
18Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
191 Mtr
202 Mtr
21Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoorinstallations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
226 fiber
23Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords"s performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
24Single Mode Patch Cord 3 Mtr.
25Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
2612 Ports
2724 Ports
28Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. withIEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
29Supply , Installation, Testing and Comissioning ofHot pluggable Small Form Factor Pluggable (SFP Module), 1000BASE-LX, 1G Fiber Channel, LC Type Duplex Connector, 1310 nm laser transmitter, Should support distance upto 10 km on 9/125 um of data rate upto 1.25 Gb/s on bi-directional data links. Should also support industrial temperature, should have metal enclosure for lower EMI. The transceiver should be ROHS Compliant. (For Each SM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
30Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
31Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with "U"Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
3215 U Rack with Width 600 mm & Depth 400 mm + 100 mm
33Supply & Installation of IP-20 & IK-08 , UL Listed Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,Vertical Mounting Rail 1.6 MM with "U"Marking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, Set of 75 mm height 4 castors, 2 of which have brakes, Accessories like: 5 Nos of 19" 1U Horizontal Cable manager, 2 Nos of vertical cable managers, 1 no. Keyboard Tray,4 Nos of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 2 No of 19" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
3442 U Rack with Width 800 mm &Depth 1000 mm with 3 no. Heavy DutySliduing Drawer
35S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along withISI marked (IS:14768 P-II 2003) accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required includingcutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
3620 mm
37SITC of UL 10th edition / EN54 / VDS certifiedAutomatic Floating Sensitivity type Analog addressable Multi criteria (two optical/Smoke sensor to reduce false alarm) detector with mounting base & LED etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
38SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
39SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
40SITC of UL 10th edition / EN54 / VDS certified Addressable control (input/output) modules/ Relay Module for shutting down lifts, Hooters, AHU"s, Acknoledgement of Sprinkler system with potential free contact monitoring Etc. as Required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
41SITC of UL 10th edition / EN54 / VDS certified Microprocessor based inteligent, Analogue addressable,modular, expandable networkableloop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 125 detectors & devices with Loop length up to 1 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module,LCD/LED unit to indicate Fire / Fault Signal of individual unit,inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
422 - Loop Panel
43Add Extra for per Loop expansion beyond Two Loop
44SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
45Add Extra for Workstation latest Intel® i5 processor, Intel Chipset motherboard, 08 GB RAM, 1 TB SATA HDD at 7200 rpm, with 2 x 4GB GPU type higher end Graphic card for H.265 compression technique with dual display ports/DVI/ HDMI port, Giga LAN Card, wireless Keyboard, wireless optical Mouse. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
46Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
472 x 1.5 sq.mm
48Non BSR Items
49Supply, Installation, Testing & Commissioning of Managed Layer-3 Intelligent Ethernet Switch providing 24 x 10/100/1000 Fast Ethernet ports with 8 dual purpose uplink ports (provision for Fiber Giga connectivity) with provision of retundent power supply with Network Advantage Software,all switches & related Fiber modules should be of same make & category for seamless integration with each other of Approved Makes: Cisco Catalyst Series or Equivalent inAvaya, Juniper )
50Supply, Installation, Testing & Commissioning of Managed Layer-2 Intelligent Ethernet POE Switches providing 08 x 10/100/1000 Fast Ethernet POE ports- 67W or better  and 2 dual purpose uplink ports (provision for Copper / Fiber Giga connectivity) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Approved Makes: Cisco Catalyst Series or Equivalent in Avaya, Juniper )
51Supply Installation Testing & Commissioning of VMS & Storage device, The device shall beRAID-6 protected, Recording, viewing and management solution for network surveillance system with 128 channels pre-licenced including mobile viewing license. It shall be designed for high speed, high capacity digital video storage and high performance play back applications. The storage array shall be a full featured RAID 6 configuration.The digital video storage array shall have inbuilt 128 TB HDD Storage, 7200 rpm, SATA, HDD, withtwo (2) redundant power supplies. The system shall have minimum 8 GB DDR3 RAM, and per channel min 3 - 4 M bits per seconds band width. The storage array shall provide an audible alarm to notify the user in the event of a failure. The system should be such that the video recording from camera should be done directly on storage array without the use of Network manager so if network manager server fails than also recording should not be effected as required in the tender and directions of Engineer-in-charge. ONVIF Profiles S & G, CE, UL Certified. The camera, software, storage should be of the same make for seamless integration with each other MAF: Tender Specific OEM authorisation is mandatory for bid consideration of Approved Makes: Bosch / Axis/ Avigilon
52Supply, Installation, Testing & Commissioning of ONVIF S/G Profile Compliance based Indoor 2MP PoE True IP IR Dome Camera with latest H.264 or H.265 Compression with 1/2.8" CMOS Sensor with built in IR Illuminator 30 Mtrs having automatic varifocal lens from 3.5 to 10 mm lens with autofocus for both day/Night operation with Camera Built In Video Analytics like as Line Crossing, Enter/Leave Field, Follow Route, Loitering, Idle/Removed,object,. Camera should having intelligent stream management and Bandwidth reduction facility for storage management and better bit rate optimization facility. Camera Should have TCP/IP recording (dual acknowledgement). Camera should have Edge based recording facility for approx 3-5 minutes without attaching any additional SD memory card in case of network failure, Camera Should support ISCSI protocol for direct communication with client station in case of management / recording server failure, Camera should have minimum Color Illumination of 0.07 lux, Mono 0.03 lux and IR on @ 0 Lux. Camera should have True WDR facility 120db or more. The on-board Trusted Platform Module (TPM) and Public Key Infrastructure (PKI) support, guarantee superior protection from malicious attacks. The 802.1x network authentication with EAP/TLS, supports TLS 1.2 with updated cipher suites including AES 256 encryption. Camera should have UL, CE, FCC certification with IP 66 and IK10 impact protection. The camera, software, storage should be of the same make for seamless integration with each other of Approved Makes: Bosch / Axis/ Avigilon
53Supply, Installation, Testing & Commissioning of ONVIF S/G Profile 2MP PoE True IP 30 mtr IR Motorised Varifocal lens Bullet Camera: Outdoor 2MP PoE True IP IR Bullet Camera with latest H.265 Compression with 1/2.8" CMOS Sensor with built in IR Illuminator 30 Mtrs having automatic varifocal lens from 3.2 to 10 mm lens with autofocus for both day/Night operation with Camera Built In Video Analytics like as Auto Tracking, Line Crossing, Enter/Leave Field, Follow Route, Loitering, Idle/Removed object, People counting, crowd density and 3D tracking. Camera should having intelligent stream management and Bandwidth reduction facility for storage management and better bit rate optimization facility. Camera should have Edge based recording facility up to 2TB. Camera should have minimum Color Illumination of 0.37 lux, Mono 0.04 lux and IR on @ 0 Lux. Camera should have True WDR facility 120db. Camera should have iDNR facility for reducing bandwidth and increasing storage. Camera should supports 4 Type of streams for viewing and recording. Camera should have onboard data security by using TPM (Trusted Platform Module) and PKI support for guaranteed and superior protection from hacking and malicious attacks. Camera should have UL, CE, FCC certification with IP 66 and IK10 impact protection. The camera, software, storage should be of the same make for seamless integration with each other(Approved Makes: Axis, Bosch, Avigilon)
54Supply ,Installation of 32 mm PN 6 grade HDPE pipe as per IS:4984 with nylon rope for fiber / LAN cable / telephone / power cable laying inclusive of digging with the help of bogi & sand finishing, making the surface in good condition as approved by engineer in charge etc
55SITC of 17"" Screen for viewing for Storage of approved Makes: Lenovo, HP, Dell.
56SITC of 55"" Flat Smart Screen HD Profesional LED with remote control and wall mount unit / floor stand complete with making connections etc of approved Makes: LG, Samsung, Panasonic.
57Supply, Installation, Testing & Commissioning of IP Phones along with Dual switched auto-sensing 10/100/1000 Mbps Ethernet ports with integrated BUILT-IN PoE+ to power the device and give it a network connection, 2 line keys with dual colour LED and 2 SIP accounts, LCD graphical display, 3 XML programmable context-sensitive soft keys,13 dedicated function keys for: MUTE, CONFERENCE, PHONEBOOK, MESSAGE, RECORD, HOME, TRANSFER, HOLD, HEADSET, MUTE, SEND/REDIAL, SPEAKERPHONE, VOL+, VOL;. Supports HD audio both on handset and full-duplex handsfree speakerphone and 3-way conference.UL & FCC/CE compliance of Approved Makes: Cisco, Alcatel, Grandstream
58Supply, Installation, Testing & Commissioning of IP Main console desk (Reception Phone) with Dual switched auto-sensing 10/100/1000 Mbps Ethernet ports with integrated PoE, 4.3 inch (480x272) TFT color LCD, 10 line keys with up to 5 SIP accounts, 5 XML programmable context sensitive softkeys, 5 navigation/menu keys, 9 dedicated function keys for:MESSAGE(with LED indicator), phonebook, transfer, conference, hold, headset, mute, send/redial, speakerphone, vol+, vol-; Call Hold, transfer, forward, call waiting, 3-way conference, call park, call pickup,off-hook auto dial, auto answer, click-to-dial, flexible dial plan, hot desking, personalized music ringtones and music on hold, integrated dual-band WiFi 802.11 a/b/g/n/ac (2.4Ghz & 5Ghz),handset and full-duplex handsfree speakerphone with wideband audio, User and administrator level passwords, MD5 & MD5-sess based authentication, AES based secure configuration file, SRTP, TLS, 802.1x media access control, UL & FCC/CE compliance of Approved Makes: Cisco, Alcatel, Grandstream
59Supply, Installation, Testing & Commissioning of extension module with 4.3 inch (272x480) TFT color LCD 20 per page (each module contains 2 pages, for up to 40 lines per module Combine up 4 daisy-chained modules for 160 contacts/extensions BLF, call park /pick-up, speed-dial, presence, intercom, voice conferencing transfer/forward and more UL & FCC/CE compliance of Approved Makes: Cisco, Alcatel, Grandstream
60Supply, Installation, Testing & Commissioning of IP PBXs appliance BOX with 500 Users Call Capacity along with 75 concurrent calls, upto 75 parties voice conference, inbuit 32GB Storage (for call recording), Network Interfaces : Three self-adaptive Gigabit ports (switched, routed or dual card mode) with PoE+, supports router mode and switch mode, Up to 5 layers of IVR (Interactive Voice Response). Call Features: Call park, call forward, call transfer, call waiting, caller ID, call record, call history, ringtone, IVR, music on hold, call routes, DID, DOD, DND, DISA, ring group, ring simultaneously, time schedule, PIN groups, call queue, pickup group, paging/intercom, voicemail, call wakeup, SCA, BLF, voicemail to email, fax to email, speed dial, call back, dial by name, emergency call, call follow me, blacklist/whitelist, voice conference, video conference, eventlist, feature codes, busy camp-on/ call completion, voice control. UL & FCC/CE compliance of Approved Makes: Cisco, Alcatel, Grandstream
61Supply, Installation, Testing & Commissioning of E1/T1 Digital VOIP Gateway BOX for digital PSTN & ISDN trunks to be integrated with IP PBXs with VoIP network with 30 concurrent calls with Dual Gigabit autosensing RJ45 network ports, TLs and SRTP security encrption technology to protect calls and accounts, supports a wide range of voice codecs including G.722, G.729 iLBC, USB and SD card interface peripheral ports. UL & FCC/CE complianceof Approved Makes: Cisco, Alcatel, Grandstream
62Supplying, Installing, Testing and Commissioning of 6-8 Watts ceiling mounted speakers for PA system (Approved Makes:- Bosch -EV/ Bose /D&B)
63Supply, laying and commissioning of PVC insulated and PVC sheathed , 2 core shieldedflexible copper wire of size 1.5mm, in existing Surface /recessed conduits ,Cable race ways, in existing already layied Pipes etc (for PA System) Approved Makes: Finolex, RR Cables, Deepcab
64Supply , installation testing and commisioning of 6 ZONE Voice Command Center withFACP, it shall contain all equipment required for all audio control, signaling and supervisory functions. This shall include speaker zone indication and control, voice units, microphone etc. The Voice Command Center shall have voice call station suitable for 6 zone, voice controller & router suitable for 6 zone, 1 nos 240 watt & 2 no 480 watt amplifier& amplifier capable for 1200 watt load etcApproved Makes :- Bosch, Honeywell, Edwards
65SITC of 5 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with 26Ahx x 16 nos SMF Batteries for min 30 min back up, with MS Rack for Barreries and required cabling for incoming & outgoing connection of approved Makes: Numeric, Eaton, Emerson, APC.
66Supply,Installation,Testing&CommissioningofDigitalChairmanUnitwithPriorityButtonandDiscussion Device that shall enable participants to take part in a discussion by speaking into a microphone and listening toproceedingsonaloudspeaker.ThedeviceshallhavePlug-and-playfunctionality,Compact,attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone with flexible stem withLoudspeakerintegratedintofront ofdevicehavingfacilityofheadphoneaswellwithAutomaticlevel reduction when microphone is activated (configurable via web browser application of Control Unit): prevents acoustic feedback from headphone to microphone.GSM immunity with having Frequency response 200Hz-12.5kHz,Loudspeakernominaloutput72dBSPL.etc (Aproved Makes: Bosch / Toa / Brahler)
67Supply,Installation,Testing&CommissioningofDigitalDelegateUnitwithSpeakButtonandDiscussion Device that shall enable participants to take part in a discussion by speaking into a microphone and listening toproceedingsonaloudspeaker.ThedeviceshallhavePlug-and-playfunctionality,Compact,attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone with flexible stem withLoudspeakerintegratedintofront ofdevicehavingfacilityofheadphoneaswellwithAutomaticlevel reduction when microphone is activated (configurable via web browser application of Control Unit): prevents acoustic feedback from headphone to microphone.GSM immunity with having Frequency response 200Hz-12.5kHz,Loudspeakernominaloutput72dBSPL. etc(Aproved Makes: Bosch / Toa / Brahler)
68Supply,Installation,Testing&CommissioningofControlUnitwithIntuitivetouch- buttons on the front panel for easy configuration and operation purposes. IntuitiveLED indicatorsfor clear andimmediatefeedbackonthesystemsettings.Webbrowsercontrol–itshallbepossibletouseaweb browser application to view and manage system settings.System control for up to 80 Discussion Devices.Hot swapofDiscussionDevices,withouthavingto powerdown thesystem. Plus/minusbuttons andgreen LED indicatorsforsettingthevolumerangeofallconnectedDiscussionDevices.Microphone-modeselection buttonandgreenLEDindicatorsforselectingoneofthefollowingmicrophoneoperatingmodes:‘open mode’, ‘override mode’, ‘voice activation mode’, and ‘push to talk (PTT) mode’. Number of Open Microphones (NOM) button and green LED indicators for selecting the number of microphones that can be activatedatthesametime.Itshallbepossibletoselect uptofouropenmicrophonesattheControlUnit. Built-in Digital Acoustic Feedback Suppression (DAFS). USB connector on front of unit for connecting a USB memorystick.Gainreductionduetonumberofopenmicrophones(NOM)1/SQRT(NOM)Sample rate 44.1kHz Nominal input (85 db SPL)<0.5% Max. input (110 db SPL) <0.5%. etc (Aproved Makes: Bosch / Toa / Brahler)
69Supply, Installation, Testing & Commissioning of Extension cables and connectors for contribution units (Default Come with 10 Mtrs)(Aproved Makes: Bosch / Toa / Brahler)
70Supply, Installation, Testing & Commissioning of Connectors & Cable Clamps of OEM Make Only (Aproved Makes: Bosch / Toa / Brahler)
71Supply & Installation of 120 Watt Mixer Amplifier Unit- for providing a crisp call or clear music with 4 microphone / line inputs, plus music source input, announcement only output, 3 wire volume override, with Mains power supply 230 VAC ±10%, 50 Hz (reduced power at lower mains),Inrush current 20 A , Power consumption 120W, Frequency response (Line) 80 Hz to 18 kHz (+1/-3 dB @-10 dB ref. rated output) Frequency response (Mic.) 80 Hz to 18 kHz (+1/-3 dB @-10 dB ref. rated output) Distortion <1%@ rated output power, 1 kHz Bass Control Max. ± 8 dB Treble Control Max. ± 8 dB, including making connection etc complete in all respect (Approved Makes:- Bosch-EV/ Bose /D&B)
72Supply, Installation, Testing & Commissioning of Handheld Wireless Mic with Cardiod polar pattern for transmitter,Dynamic microphone with Neodymium magnet , Receiver frequency response 80Hz-18kHz,Receiver RF sensitivity < 1.0 µV,Receiver Image rejection>55dB,Receiver Dyanmic range >95dB and receiverhaving 32 channels possible,Receiver S/N ratio >100dB A,distortion <1 %, Transmitter sensitivity - 3.2 mV/Pa,modulation:+/-40kHz(Approved Makes:- Bosch-EV/ Bose /D&B)
73Supply, Installation, Testing & Commissioning of High-performance 19.5 meter HDMI male to HDMI male cable that supports signals up to 4K@60Hz (4:4:4), Deep color Should have Gold Plated pins Should have lockable connectors Should be of same make of Switcher,Scaler,Wall plate for the interoperability in all respect complete in all respect (Approved make: Kramer/Extron/Manhatten)
74Supply & Laying of of 2 Core X 1.5 Sqmm Speaker Cable for connecting speakers to controller Approved Makes: Finolex, RR Cables, Deepcab
75Supply, Installation, Testing & Commissioning of Motorized Screen: Wall mountable Motorized Screen with minimum 119” Diagonal Size or higher, Aspect Ratio: 16:9, Fabric: HD-MW, Motor: Tubular Motor, Remote: RF Remote of Approved Makes: Suvira /Talon/ draper / liberty / Grandview
76Supply testing and commissioning of LCD projector, Brightness 4100 Lumens, Screen Size: 0.76–7.62 m (30–300 inches) diagonally, 4:3 aspect ratio, Resolution: 1,024 × 768 pixels, (Input signals that exceed this resolution will be converted to 1,024 × 768 pixels.), Lamp: Power consumption: 300 W (6 W when Standby mode set to Normal, 0.5 W when Standby mode set to Eco*1), Panel size: 16 mm (0.63 inches) diagonal (4:3 aspect ratio, Pixels: 786,432 (1,024 × 768) pixels, HDMI, VGA, VIDEO AUDIO LAN, USB, , Dimensions (W × H × D) 335 mm × 96 mm (when legs at shortest position) × 252 mm including making connection etc complete in all respect of aproved makes : Sony/ Panasonic/BenQ/ EPSON
77Supply & testing and commissioning of Ceiling Mount Kit 2FT Ceiling-mount capability • Extremely flexible design allow to fit almost all popular projectors • Quick release universal mount for Projector • 360 degrees Rotate for Projector • +/- 20 degrees Tilt and Roll for Projector • Adjustable-height from 11.42” to 32” (290mm-810mm) • Cable-routing channel for a clean look • Cable management including fixing with fastner etc as required complete in all respect
78Queue management system
79SITC of 55"" Flat Smart Screen HD Profesional LED with remote control and wall mount unit / floor stand complete with making connections etc (Approved makes: LG / Panasonic / Samsung or Equivalent as approved by Engiineer Incharge)
80Supply, Installation, Testing & Commissioning of 15.6 inch Token display etc. all complete. (Approved Makes - Aaztec/ Sharp / Tenwave Infotech or Equivalent as approved by Engiineer Incharge)
81Supply, Installation, Testing & Commissioning of 22" Kiosk for Token generation touch screen , 22 inch Touch display / LASER Printer /CPU  /API/ Barcode Reader/ Token Generation media player, thermal printer (Approved Makes - Aaztec/ Sharp / Tenwave Infotech or Equivalent as approved by Engiineer Incharge)
82Note :- For Queue management system IHMS system software shall be provided by GOR. The system supplied by the vendor should run on that software.