| 1 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, madewith 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 2 | Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete. |
| 3 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. |
| 4 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 5 | Removingtheexistingcementplasterofanythicknesswithoutcausingdustnuisanceand stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. |
| 6 | Chipping /removing loose concrete upto reinforcement bars, without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc complete. |
| 7 | Providing and fixing 6 mm thick commercial plywood with jungle wood frame work of 50 x 35 mm size at 60 cm on both ways for closing the window portion/openings for protection from falling debris, dust etc. including cutting, fixing with nails and removing after the same after completion of the work. (To be used after approval of SuperintendingEngineer) |
| 8 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 9 | Transportation of excavated earth including loading and unloading per truck trip of 5.00 cubic meter capacity per trip. (15KM) |
| 10 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 11 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 12 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 13 | Demolishing R.C.C. slab, R.C.C. wall of any thickness, R.C.C.beams, joists, R.C.C. columns, piles, pile caps etc., in any thickness and size manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 14 | Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metres lead. A)For thickness of tiles 10 mm to 25 mm |
| 15 | B) For thickness of tiles above 25 mm and up to 40 mm |
| 16 | Removing and refixing existing door or window with frames andshutters, making good the damaged brick work and applying 3coats of Syn. Ena. Paint |
| 17 | Removing existing R.C.C. jallies of any design & deposit to ward store complete. |
| 18 | Providing precast cement concrete Jali of Nominal Mix 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. A) 50 mm thickcomplete excluding plastering of the jambs, sills and soffits. |
| 19 | 40 mm thick |
| 20 | 25 mm thick |
| 21 | Providing and applying two coat of anticorrosive polymer\"Rust-remover\"of approvedquality coating to the steel surface by exposing the reinforcement, removingdust, only residue and existing paint if any thorughly and washing the surface withwater etc.complete asdirected. |
| 22 | Bars upto 12 mm diameter |
| 23 | Bars above 12 mm diameter |
| 24 | Carry out application of \"Bi-polar migratory corrosion inhibitor\" on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100mm, through pores of concrete,inhibiting the corrosion etc complete. |
| 25 | Providing filling of Micro-concrete and 10 mm aggreagate ( 1:1) including scarificial leakproof MS shuttering includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc., complete |
| 26 | Providing protection of unexposed old reinforcement on non spalled concrete by insertion of sustained release corrosion inhibitor caplets like POWRTHROW sustained release Corrosion inhibiting caplets of to protect both anodic & cathodic sites and shall reduce to reduce corrosion potential Ecorr by minimum 80 mV in conductive medium, by drilling 20 mm holes into the concrete at a depth of 25 mm and inserts to be filles by EPCO-PC-Putty. Caplets shall inhibit corrosion inhibition efficiency of 98% (when added 0.03% by weight) against control sample evaluated by Tafel polarization method. Depth of penetration for effective corrosion protection shall be 120 mm and film formation of 20 Microns as evaluated by CSIR-CECRI Karaikudi. |
| 27 | Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another innovate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, formaldehyde based polymer with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate. (If scaffolding is required, same shall be provided and will be paid under relevant item)(15- 30 mm thickness at a time). |
| 28 | Providing and applying “high strength, non shrink free flow grout material” i. e. micro concrete (like shrink comp or equivalent) having compressive strength as 400 Kilogram/sq.cm. including finishing the surface and curing for 07 days. Etc complete. The usage of this non shrink concrete with zero slump is to allow to occupy every free space leaving no voids, thereby producing dense concrete with proper bonding with concrete (The quoted rates to be inclusive of all materials, labours, tools & tackles, transportation, taxes etc complete) to be applied for foundation and strengthening of pier etc and as per the direction of Site-In-Charge. (The product like Ultratech/Rendroc (RGL) of FOSROC or its equivalent) |
| 29 | Providing leak proof treatment by Injection grouting method to old floor without removing tiles of W.C., bath, with cement sand proportion of 1:1.5 and waterproofing compound at 2 Kilogram/bag of cement mixed in 35 liters of water including drilling holes in required position grouting with above mixed solution and ceiling etc. complete. |
| 30 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. |
| 31 | Providing and fixing in position HCRM / CRS (CorrosionResistant Steel) bar reinforcement ofvariousdiametersforR.C.C.pilecaps,footings,foundations,slabs,beamscolumns, canopies,staircase,newels,chajjas,lintelspardis,copings,fins,archesetc.asperdetailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 32 | Shear Connectors: Make 10/12 mm dia holes using heavy duty electrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig-zag fashion, clean the holes using air jet and fix pre-fabricated 100 x 50 mm L-shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend. The shear connectors are used to tie the additional reinforcement bars |
| 33 | Supplying, Drilling/ Cleaning hole and injecting chemical .Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines.The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drillbit sor hollow drill bits to the required depth by rotaryhammerdrill, cleaning with brush and jet of clean air,filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDEA22 battery dispenser along with piston plug.The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedmen to frebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/design engineer for approval.Scanning before drilling to be done to avoid hitting existing rebars. HY200 -16 mm dia 320mm depth |
| 34 | Supplying, Drilling/Cleaning hole and injecting Hilti make ETAA pproved RE 500 V 3 chemical. Application to be designed separately for Rebars as Simply Supported, Momentor Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines. Thechemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air,filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDEA 22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer‘s recommendations.The adequate diameter and embedment of rebars to be decided as per PROFIS RebarSoftware&thereporttobesubmittedtotheproject manager / design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depth |
| 35 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the settinginstructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -12 mm dia 240mm depth |
| 36 | Supplying, Drilling/Cleaning hole and injecting Hilti make ETAA pproved RE 500 V 3 chemical. Application to be designed separately for Rebars as Simply Supported, Momentor Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines. Thechemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air,filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDEA 22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer‘s recommendations.The adequate diameter and embedment of rebars to be decided as per PROFIS RebarSoftware&thereporttobesubmittedtotheproject manager / design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -8mm dia 160mm depth |
| 37 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means |
| 38 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramming ,watering including shoring andstrutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means |
| 39 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete. |
| 40 | Providing and grouting the holes by Poly Ceramic Cementitious i.e NicGrout G 06 + 53 grade cement material of as per requirement to reduce the porosity of concrete / Masonry structure and to increase the strength of structure using grouting pipes , grouting m/c, mixer etc and all relevant safety with all leads and lifts, material, machinery, labour, etc. Complete as per specification and as directed by Engineer-in-Charge. |
| 41 | Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for plain or molded sills, cornice, jambs, block in course, or architraves of required size and shapes including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer etc. complete, With fine aggregate (Crushed sand VSI Grade) |
| 42 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 43 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 44 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 45 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 46 | Providing andlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 47 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite /quartzite/gneissmetalforR.C.C.columnsasperdetaileddesignsanddrawingsoras directedincludingsteelcentering,formwork,coverblocks,laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smoothand even surface or roughening if special finish is to be providedand curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 48 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 49 | Providing and fixing chicken mesh of 22 gauge,with about 30cm. Width at the junction of R.C.C members and brickwork,of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. |
| 50 | Injecting approved low viscous epoxy grout into concrete slab, stone masonry cracks, columns etc. by suitable gun/ pump (using Araldite GY-257 & Aradur -21 in 1:0.21 prop.) at required pressures by providing necessary scaffolding, drilling and inserting 12mm dia.Brass grouting multiperforated nipples upto 30mm to 40mm depth, using M Seal,Quartz sand around the nipple, cutting of nipples after curing, cleaning etc. complete. (This item shall be paid on actual onsumption of epoxy used in Kgs.) |
| 51 | Strengtheningstructural elements byproviding & fixing CARBON FIBER (Make Sika or BASF or FOSROC) Surface preparation: Grinding concrete substrate, cleaning it with wire brush removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc. complete.Profiling: providing & Applying compatible Mbrace primer on prepared substrate, Filling the holes and uneven surface withhigh strength epoxy putty etc. complete IF Required. Wrapping: Providing & Applying first coat of Saturant, cutting the carbon fiber sheet to size, wrapping the fiber sheet to structural element at desired orientation using tamping roller to avoid any air voids etc. complete.Sand pasting: Providing & Applying second coat ofSaturant after min. 12 hrs, rectify air voids if any paste the rive sand on it to make surface rough to take any further finishes(Mode of measurement: Per sq.mt of Mbrace CF 400 sheet applied and not surface area of Concrete application & Quantity will be measured including wastage) The rate includes all type of material,application,equipment & scaffolding etc complete. Rate is applicable for all height & level. |
| 52 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 53 | Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved qualityand shade complete. |
| 54 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. |
| 55 | Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) |
| 56 | Injecting approved low viscous epoxy grout into concrete slab, stone masonry cracks, columns etc. by suitable gun/ pump (using Araldite GY-257 & Aradur -21 in 1:0.21 prop.) at required pressures by providing necessary scaffolding, drilling and inserting 12mm dia.Brass grouting multiperforated nipples upto 30mm to 40mm depth, using M Seal,Quartz sand around the nipple, cutting of nipples after curing, cleaning etc. complete. (This item shall be paid on actual onsumption of epoxy used in Kgs.) |
| 57 | Jacketting the existing column of size as shown in the drawing by removing the concrete cover to reinforcement, by chipping or other suitable means to expose the reinforcement of existing column in order to make available the same for binding the extra reinforcement as shown in the drawing and also removal of rust, scales of the reinforcement in order to provide and apply approved make of epoxy resin to get proper bond with newly laid M25 grade concrete. The aforesaid concrete shall be laid by the sides of the existing column with uniform thickness of 115 mm or as specified, for jacketing purposes thereby increasing the sectional dimensions by 150 mm or as specified (excluding finishing) at any height with requisite shuttering, centring, scaffolding, proping, repairing the existing surface as specified and also removal of debris, curing etc. complete as per design and drawing etc. directed. (NOTE :- Reinforcement will be paid separately under respective item of schedule ). |
| 58 | Jacketting the existing beam or beam connections as shown in the drawing by removing the concrete cover to reinforcement, by chipping or other suitable means to expose the reinforcement of existing beam or beam connections in order to make available the same for binding the extra reinforcement as shown in the drawing and also removal of rust, scales of the reinforcement in order to provide and apply approved make of epoxy resin to get proper bond with newly laid M25 grade concrete. The aforesaid concrete shall be laid by the sides of the existing beam with uniform thickness of 75 mm or as specified, for jacketing purposes thereby increasing the sectional dimensions by 100 mm or as specified (excluding finishing) at any height with requisite shuttering, centring, scaffolding, proping, repairing the existing surface as specified and also removal of debris, curing etc. complete as per design and drawing etc. directed. (NOTE :- Reinforcement will be paid separately under respective item of schedule ). |
| 59 | Providing expansion joints in R.C.C. framed structure (at floor level) with plain premoulded filler 25 mm thick with 75 mm wide and 1 mm thick stainless steel platand finishing etc. complete. |
| 60 | Providing expansion joints in R.C.C. framed structure (exterior column) with plain premoulded filler 25 mm thick with 75 mm wide and 1 mm thick stainless steel plate and finishing etc. complete. |
| 61 | Providing expansion joints in reinforced cement concrete framed structure (interior columns) with plain premoulded filler with confirming to IS 1838,1961, 25 mm thick with 75 mm wide and 1 mm thick stainless steel plate finishing etc. complete as directed |
| 62 | Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). |
| 63 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 64 | Providing internal cement plaster 12mm thick insingle coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. |
| 65 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 66 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 67 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. |
| 68 | Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. |
| 69 | Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application of TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/ One Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/ One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/ One Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. |
| 70 | Providing and laying C.C. floor of mix M-25 with ready mixed concrete from RMC. The ready mixed concrete shall be laid and vibrated with a poker vibrator and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as perspecifications and directions of Engineer-in-charge. The channel shuttering spaced 4m apart shall be included in this item.) |
| 71 | Clean the existing surface / terrace thoroughly to remove dirt, loose particles, laitance etc. For emergency waterproofing of existing terrace. Use a vacuum cleaner or high pressure jet or wire brushing as per requirement. Examine the surface closely for any cracks. Fill it with acrylic polymeric non-shrink crack filler putty as approved by Engineer in charge a pure aliphatic, acrylic, polymer modified ready to use paste. After filling, allow the surface to dry for atleast 24 hrs. If the depth of the crack is more than 2-3 mm apply in layers at intervals. Moisten the surface with a water jet one day prior to the application of waterproofing coating. Mix 1 part of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) membrane as approved by Engineer in charge and 1 part of grey cement by weight using a low speed mechanical stirrer to form slurry lump free consistency. Apply this as a primer coat of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) membrane as approved by Engineer in charge. Apply the same slurry by roller at 24 hrs interval between the applications of each coat. Extend the coating to parapet walls. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of pure enoate based polymer titanium dioxide based 2-(methoxycarbonyl)-1-propene-butyl-2 propenoate (TMPBP) and 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) of waterproof coating as approved by Engineer in charge on surface. Ensure that no pinholes are let untouched. Allow the membrane to cure for 24-48 hours. Single Component, UV Resistant, Elastomeric, High Build Waterproof Coating (Confirming to DIN 1048) should have following minimum properties: 1) Elongation % (ASTM D 638): @ 400% 2) Tensile Strength (ASTM D 412): 150 psi 3) Water Permeability (DIN 1048): Zero 4) Solids: > 65% 5) pH: 8.5 - 10.5 |
| 72 | Providing and applying a base coatcomprisingof1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. |
| 73 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. |
| 74 | Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. |
| 75 | Providing and applying two coats of lead/zinc base oil paint/ bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc. complete. (excluding primer coat). |
| 76 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 77 | Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. |
| 78 | Dismantling aluminium/ glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 79 | Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre.The shutter should be of bearing bottom 40 x 18 x 1.25 mmat weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass andaluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box |
| 80 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, madewith 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 81 | Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete. |
| 82 | Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. |
| 83 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 84 | Removingtheexistingcementplasterofanythicknesswithoutcausingdustnuisanceand stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc. complete. |
| 85 | Chipping /removing loose concrete upto reinforcement bars, without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc complete. |
| 86 | Providing and fixing 6 mm thick commercial plywood with jungle wood frame work of 50 x 35 mm size at 60 cm on both ways for closing the window portion/openings for protection from falling debris, dust etc. including cutting, fixing with nails and removing after the same after completion of the work. (To be used after approval of SuperintendingEngineer) |
| 87 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 88 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. |
| 89 | Transportation of excavated earth including loading and unloading per truck trip of 6.00 cubic meter capacity per trip. (10KM) |
| 90 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 91 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 92 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) |
| 93 | Providing and applying two coat of anticorrosive polymer\"Rust-remover\"of approvedquality coating to the steel surface by exposing the reinforcement, removingdust, only residue and existing paint if any thorughly and washing the surface withwater etc.complete asdirected. Bars upto 12 mm diameter |
| 94 | Bars above 12 mm diameter |
| 95 | Carry out application of \"Bi-polar migratory corrosion inhibitor\" on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100mm, through pores of concrete,inhibiting the corrosion etc complete. |
| 96 | Removal of plants / ficus grown by pulling out root system embedded in masnory, cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide \"Glycel\" (iso proplamine salt of glyphosate) or other chemical as specified by the Engineer incharge etc. complete. |
| 97 | Providing filling of Micro-concrete and 10 mm aggreagate ( 1:1) including scarificial leakproof MS shuttering includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc., complete |
| 98 | Providing protection of unexposed old reinforcement on non spalled concrete by insertion of sustained release corrosion inhibitor caplets like POWRTHROW sustained release Corrosion inhibiting caplets of to protect both anodic & cathodic sites and shall reduce to reduce corrosion potential Ecorr by minimum 80 mV in conductive medium, by drilling 20 mm holes into the concrete at a depth of 25 mm and inserts to be filles by EPCO-PC-Putty. Caplets shall inhibit corrosion inhibition efficiency of 98% (when added 0.03% by weight) against control sample evaluated by Tafel polarization method. Depth of penetration for effective corrosion protection shall be 120 mm and film formation of 20 Microns as evaluated by CSIR-CECRI Karaikudi. |
| 99 | Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another innovate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, formaldehyde based polymer with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate. (If scaffolding is required, same shall be provided and will be paid under relevant item)(15- 30 mm thickness at a time). |
| 100 | Providing and applying “high strength, non shrink free flow grout material” i. e. micro concrete (like shrink comp or equivalent) having compressive strength as 400 Kilogram/sq.cm. including finishing the surface and curing for 07 days. Etc complete. The usage of this non shrink concrete with zero slump is to allow to occupy every free space leaving no voids, thereby producing dense concrete with proper bonding with concrete (The quoted rates to be inclusive of all materials, labours, tools & tackles, transportation, taxes etc complete) to be applied for foundation and strengthening of pier etc and as per the direction of Site-In-Charge. (The product like Ultratech/Rendroc (RGL) of FOSROC or its equivalent) |
| 101 | Providing leak proof treatment by Injection grouting method to old floor without removing tiles of W.C., bath, with cement sand proportion of 1:1.5 and waterproofing compound at 2 Kilogram/bag of cement mixed in 35 liters of water including drilling holes in required position grouting with above mixed solution and ceiling etc.complete. |
| 102 | Providing and fixing 16 mm thick all weather proof Bison board over frame of M.S. angles and channels (to be paid seperately) including T.W. battens mm and beading scaffolding if necessary, all etc. complete. |
| 103 | Providing and fixing in position HCRM / CRS (CorrosionResistant Steel) bar reinforcement ofvariousdiametersforR.C.C.pilecaps,footings,foundations,slabs,beamscolumns, canopies,staircase,newels,chajjas,lintelspardis,copings,fins,archesetc.asperdetailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 104 | Shear Connectors: Make 10/12 mm dia holes using heavy duty electrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig-zag fashion, clean the holes using air jet and fix pre-fabricated 100 x 50 mm L-shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend. The shear connectors are used to tie the additional reinforcement bars |
| 105 | Supplying, Drilling/ Cleaning hole and injecting chemical .Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines.The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drillbit sor hollow drill bits to the required depth by rotaryhammerdrill, cleaning with brush and jet of clean air,filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDEA22 battery dispenser along with piston plug.The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedmen to frebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/design engineer for approval.Scanning before drilling to be done to avoid hitting existing rebars. HY200 -16 mm dia 320mm depth |
| 106 | Supplying, Drilling/Cleaning hole and injecting Hilti make ETAA pproved RE 500 V 3 chemical. Application to be designed separately for Rebars as Simply Supported, Momentor Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines. Thechemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air,filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDEA 22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer‘s recommendations.The adequate diameter and embedment of rebars to be decided as per PROFIS RebarSoftware&thereporttobesubmittedtotheproject manager / design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depth |
| 107 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the settinginstructions should be strictly followed as per the manufacturer’s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -12 mm dia 240mm depth |
| 108 | Supplying, Drilling/Cleaning hole and injecting Hilti make ETAA pproved RE 500 V 3 chemical. Application to be designed separately for Rebars as Simply Supported, Momentor Splice Connection as per EC2/TR023 or relevant tested and accepted rebar guidelines. Thechemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air,filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDEA 22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer‘s recommendations.The adequate diameter and embedment of rebars to be decided as per PROFIS RebarSoftware&thereporttobesubmittedtotheproject manager / design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -8mm dia 160mm depth |
| 109 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means |
| 110 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling withavailable earth/murum, ramming ,watering including shoring andstrutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means |
| 111 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete. |
| 112 | Jacketting the existing beam or beam connections as shown in the drawing by removing the concrete cover to reinforcement, by chipping or other suitable means to expose the reinforcement of existing beam or beam connections in order to make available the same for binding the extra reinforcement as shown in the drawing and also removal of rust, scales of the reinforcement in order to provide and apply approved make of epoxy resin to get proper bond with newly laid M25 grade concrete. The aforesaid concrete shall be laid by the sides of the existing beam with uniform thickness of 75 mm or as specified, for jacketing purposes thereby increasing the sectional dimensions by 100 mm or as specified (excluding finishing) at any height with requisite shuttering, centring, scaffolding, proping, repairing the existing surface as specified and also removal of debris, curing etc. complete as per design and drawing etc. directed. (NOTE :- Reinforcement will be paid separately under respective item of schedule ). |
| 113 | Providing and grouting the holes by Poly Ceramic Cementitious i.e NicGrout G 06 + 53 grade cement material of as per requirement to reduce the porosity of concrete / Masonry structure and to increase the strength of structure using grouting pipes , grouting m/c, mixer etc and all relevant safety with all leads and lifts, material, machinery, labour, etc. Complete as per specification and as directed by Engineer-in-Charge. |
| 114 | Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for plain or molded sills, cornice, jambs, block in course, or architraves of required size and shapes including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer etc. complete, With fine aggregate (Crushed sand VSI Grade) |
| 115 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 116 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 117 | Providing andlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 118 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite /quartzite/gneissmetalforR.C.C.columnsasperdetaileddesignsanddrawingsoras directedincludingsteelcentering,formwork,coverblocks,laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smoothand even surface or roughening if special finish is to be providedand curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 119 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 120 | Providing and fixing chicken mesh of 22 gauge,with about 30cm. Width at the junction of R.C.C members and brickwork,of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. |
| 121 | Injecting approved low viscous epoxy grout into concrete slab, stone masonry cracks, columns etc. by suitable gun/ pump (using Araldite GY-257 & Aradur -21 in 1:0.21 prop.) at required pressures by providing necessary scaffolding, drilling and inserting 12mm dia.Brass grouting multiperforated nipples upto 30mm to 40mm depth, using M Seal,Quartz sand around the nipple, cutting of nipples after curing, cleaning etc. complete. (This item shall be paid on actual onsumption of epoxy used in Kgs.) |
| 122 | Strengtheningstructural elements byproviding & fixing CARBON FIBER (Make Sika or BASF or FOSROC) Surface preparation: Grinding concrete substrate, cleaning it with wire brush removing oil, laitance if present, rounding sharp edges to min 25 mm radius etc. complete.Profiling: providing & Applying compatible Mbrace primer on prepared substrate, Filling the holes and uneven surface withhigh strength epoxy putty etc. complete IF Required. Wrapping: Providing & Applying first coat of Saturant, cutting the carbon fiber sheet to size, wrapping the fiber sheet to structural element at desired orientation using tamping roller to avoid any air voids etc. complete.Sand pasting: Providing & Applying second coat ofSaturant after min. 12 hrs, rectify air voids if any paste the rive sand on it to make surface rough to take any further finishes(Mode of measurement: Per sq.mt of Mbrace CF 400 sheet applied and not surface area of Concrete application & Quantity will be measured including wastage) The rate includes all type of material,application,equipment & scaffolding etc complete. Rate is applicable for all height & level. |
| 123 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 124 | Providing internal cement plaster 12mm thick insingle coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. |
| 125 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 126 | Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. |
| 127 | Providing Water proofing treatment to old terraces by removing existing treatment, sealing of cracks by non shrink crack fill compound applying first coat of polymer modified semi- viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion (1 litre polymer : 2 Kg Cement ) to a neatly cleaned and dust free concrete surface and upto 300 mm over parapet wall prepared by removing loose and deposited material with brush and water, followed by a coat of flexible cementious coating eg. MYK- Aqufine U.M., EL Monobond or equivalent as per manufacturer specification after laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover of 20 mm water proof plaster after sufficient curing 40 to 75 mm IPS 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound and polypropylene fibres @ 125 gm per bag of cement within it conforming to IS in pannels making groove 3 to 4 mm wide & 10 mm deep & 3m/4m or as per site condition & filling the joints with polt sulphide sealant after curing, including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry including curing as directed and ponding the surface as directed etc. complete; covering 10 years guarantee against leakproofness on Court Fee Stamp Paper of Rs. 100/- |
| 128 | Waterproofing Treatment to new terrace by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties: (1) Elongation % (ASTM D412-2016): @ 100% (2) Tensile Strength N/mm2 (ASTM D412-2016): 3.3 (3) Specific Gravity: 1.02 ±0.02(4) Total Solids (ASTM D1644-2012): 43.98 (5) Hardness Shore A (ASTMD2240-2015): 82 |
| 129 | Providing and applying a base coatcomprisingof1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. |
| 130 | Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. |
| 131 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 132 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete |
| 133 | Removing ventilators and smallwindows with frames and stacking the materials as directed with all leads, lifts etc. complete. |
| 134 | Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete. |
| 135 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 136 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 137 | Providing internal cement plaster 25 mm thick in single coat using Ready to use wall plaster in cement mortar 1:4 to concrete, brick, stone surfaces in all positions including scaffolding and curing. Providing groove at joint of B.B. Masonry and concrete members complete. With Prior Approval of Concerned |
| 138 | Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 139 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete |
| 140 | Providing and laying vitrified gloss finish tiles having size 600mm By 600mm of 8 to 10mm thickness and confirming IS.15622 2006 (GroupBla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete. |
| 141 | Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for Flooring/dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete (FOR TOILETS) |
| 142 | Providing and laying vitrified tiles having size 1200mm By 600mm of 8 to 10mm thickness and confirming IS.15622 2006 (GroupBla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete. |
| 143 | Providing & Fixing in position,Anti Static Vinyl Flooring of approved make and shade in roll form over prepared existing surface and joined to make it seamless, at all levels, as per manufacturers specifications including coving rounded junction between floor and wall. The rate shall include all cutting and wastage, cost of all materials, adhesives etc. complete. Before laying, the existing flooring should be made free from dust and undulations. The finished flooring should be free from air bubbles and thoroughly cleaned without undulations, complete and as directed.Rate to be inclusive of 150mm high coving at skirting lvl. |
| 144 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30cm x 30cm and confirming to IS15622-2006 (Group - BIIA) for antiskid flooringin required position laid on a bed of 1:4 cement mortarin cluding cement float, filling joint with cement slurry cleaning curing etc. complete. (FOR DADO) |
| 145 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (FOR STAIRCASE) |
| 146 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (FOR RAMP) |
| 147 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. |
| 148 | Providing and fixing Modular false ceiling with tegular edge and 15 mm thickness, visible surface of each tile is 7 mm below the grid, visible surface is a batch painted glass tissue in white, back of the tile covered with glass tissue. Environmental Footprint - Environmental Product declaration (EPD) acc to international ISO 14025 & EN 15804 series of standards.• Circularity - Minimum post-consumer recycled content 47%, Fully recyclable• Humidity Resistance -Class C, relative humidity 95% and 30°C, according to EN 13964:2014 • Light Reflectance - 83% light reflectance.Cleanability- Weekly dusting and vacuum cleaning. • Accessibility - The tiles are easily demountable CE Marking -ceiling systems with CE marked according to the European harmonized standard EN13964:2014. CE marked construction products are covered by a Declaration of Performance (DOP) which enables customers and users to easily compare performance of products available on the European market. • Size 600x600x15mm, 1200x600x15mm• Manufacturing- Manufactured in Sweden, production unit is ISO 14001 certified. • Acoustics-Sound absorption (Alpha W) - 1 at 200 mm o.d.s as per EN ISO 354 • Acoustics-Sound absorption Class - Class A at 200 mm o.d.s as per EN ISO 11654• NRC - 0.8 NRC as per ASTM C 423• Fire Safety - Tested and classified as non-combustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501-1 – European Standard.• Flexural tensile strength - Class C/3N• Indoor Air quality - Complying with the French regulation on VOC emissions, A level. Certified by the Finnish Building Information Group (RTS) with the M1 label. Certified by Eurofins Indoor Air comfort® . • Product Certified under GRIHA council of India for Green Ratings, IGBC Green Pro certified, Comply with the REACH regulation of the European chemical Agency, certified by the EUCEB which confirms that mineral wool is produced in conformity with the Note Q of EC No 1272/2008 and therefore classification as a carcinogen does not apply. |
| 149 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete |
| 150 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate proportion of water of allow to dry for period of 4 to 5 days For Gypsum ceilings |
| 151 | For walls |
| 152 | W10- PERFORATED ACOUSTIC WALL PANELING (Provisoinal Quantity) Providing and Fixing Channelled perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, InteriorWhite, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm or 21mm of visible pane (G-13/ G-21). The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. for G-21 and 0.6 for G-13. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge. This include Black colour sound abrsortion Fabric as backing . |
| 153 | Providing & Fixing in position, 12mm wp Plywood & 1.5 mm laminate panels above the fabricated frame on one side, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete |
| 154 | Providing & fixing 6mm thk Back painted glass of approved shade with recommended adhesive of approved make,paneling to be made with 18mm thk ply and 50x50mm thk wooden framing 600c/c Ply paneling rate is added 15% |
| 155 | Providing and fixing Country cut teak wood single leaf door shutter with teak wood style and rail of 25 mm thick including fixing 50 mm x 25 mm size welded mesh of 10 gauge as per detailed drawing or as directed with stainless steel fixture and fastening finishing with oil painting 3 coats complete |
| 156 | Providing and fixing Country cut teak wood double leaf door shutter with teak wood style and rail of 25 mm thick including fixing 50 mm x 25 mm size welded mesh of 10 gauge as per detailed drawing or as directed with stainless steel fixture and fastening finishing with oil painting 3 coats complete |
| 157 | Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on onestyle and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelimcolours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. |
| 158 | GANNAWood Door Frame (0.06x0.1x2.4x2)+ (0.06x0.1x1.2x1) = 0.036x35.314=1.27CFT |
| 159 | Providing and fixing pre-polished Twin Granite Door Frames 150mm - 250mm wide, in cement mortar 1:3 (1 cement : 3 fine sand), inclusive of all mitred joinery inclusive of all necessary joinery in Araldite and cement paste etc. All exposed surfaces and edges to be full round bull nosed / chamfered and mirror polished with 6mm wide groove to be made in wall at the junction of stone and finished surface of wall complete as directed. |
| 160 | Providing and applying three coats of synthetic enamel paint of approved color to new and old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface including primer coat ( make: Asian, dulux ) |
| 161 | Providing and fixing green marble of 18 to 20 mm thick for door frame/ dado/window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. |
| 162 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. |
| 163 | Providing and applying duco paint of approved quality, colour and shade to old and new surfaces in single coat including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. |
| 164 | Single Bed @ 2025LX 1000DX 650H Providing and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow. Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. Theoverall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. |
| 165 | Bed Side Table @ 400LX 400DX 415H Providing and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding |
| 166 | Providing and fixing ply partition of height 1500 mm with 12mm ply and 1.5mm thick laminate finish |
| 167 | Providing and fixing Aluminum Mosquito Net |
| 168 | Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. |
| 169 | 5mm thk mirror fixed on 12 mm thk marine ply on wooden beading patti on all 4 sides. |
| 170 | Trash bins / Dust BinsProviding and supplying trash bins ( max 450 in height )made up of moulded plastic with lid mechanism as per selection. |
| 171 | Providing & arranging Indoor plants |
| 172 | Providing & arrangingPaintings & Artwork |
| 173 | Providing & fixing notice board |
| 174 | DIRECTIONAL SIGNAGESDesign, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6\" x 9\"designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as permanufacturers specifications on the wallattheapprovedlocationandataheightof1200mmfromFFLandasperthe directions by the engineer in charge. |
| 175 | B) Room Tags signages |
| 176 | Supply and installation of cubicles of width and depth as per Athena Lite- SS Series Cubicles- Std Sizes (W x D x H): 900 mm x 1550 mm x 2105 mm, (Height is including 100 mm gap from bottom, Door Width- 600 mm specifications/ site drawings). Cubicle height to be 2105 mm. Made from solid grade compact high pressure laminate as perIS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature >120°C, All doors will be of single colour and made of 12 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminium grade 6063 T5-50 micron epoxy powder coated for surface protection, Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U Channel Wall joinery section,Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.etc complete. |
| 177 | Modular OT - Contructed in Corian Wall finishes, Ceiling & Vinyl Flooring |
| 178 | Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) |
| 179 | Providing andsupplying Ironing Board |
| 180 | Providing andsupplying Clothing racks |
| 181 | Supply & installation of precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.60 mm +/- 5% total coated thickness (TCT) thick Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(basic rate 300rs per sqmt to 500 rs per Sqmt) |
| 182 | Providing and fixing 75mm thick Everest Rapicon Wall partition till 4.5 m height, comprising GI Floor track of size 78mm having unequal flanges of 25mm and 15mm and 0.9mm thick and Ceiling track of size 78mm, having two equal flanges of 32mm and thickness 0.9mm fixed to floor and RCC soffit/ steel structure frame, in plumb to each other with metal anchor fasteners of size 45 x 8mm/ hex head screw of size N6 x 45mm (for anchoring the ceiling track profiles to the structural steel members). Everest Rapicon Wall panel (factory beveled or beveled at site)(having apparent density minimum 700-800 Kg/cum, Thermal Conductivity K Value as 0.12K.cal/h.m°C, Fire Rating of 134min Tested as per BS 476 Part 20-22, Sound Transmission Class of panels must be 40dB Tested as per IS 9901 Part-3; 1981) of width 600mm and height 2400mm/ 2700mm/ 3000mm will be inserted into floor and ceiling track profiles, in vertical position. The height above 3.0 m shall be achieved by staggering the joints along the longitudinal side of the panel to a minimum overlap of 1.5 m. The tongue and groove joints of every single panel, which includes the horizontal joints shall be sealed with a mixture of Sodium Silicate and Fly Ash in 15:1 ratio (by volume) for permanent joint rigidity. Finally, the joints at the surface shall be jointed and finished with Everest jointing compound and joint fibre mesh tape.For Fire Rated Walls – Groove at peripheral wall joints shall be filled with Fire cum acoustic sealant backed with backer rod.For Exterior Walls – For wall height upto 3m, Rapicon joints on the exterior face is sealed with exterior grade paintable sealant. For bigger Span Wall - SHS columns shall be provided as stiffeners at every 4.2 m of wall span |
| 183 | Providing and supplying of Tandem chairs |
| 184 | Providing and fixing M.S.grill door 24 Kilogram /One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc |
| 185 | Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) |
| 186 | Providing and fixing wall hung white wash basin of size 550 x 400 x 195 mm with pillar cock having flow rate up to 6.0 Litr/Minute,C.P.Angular stop cock long thread of Jaquar/Cera/Hindware /Perryware or equivalent make, including SS bottal trap of approved make etc complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) |
| 187 | Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer\"s Green product and shall got approved from the Engineer In Charge.) |
| 188 | Providing and fixing white glazed urinal with Pressmatic auto closing valve having flow rate up to 4.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make with P.V.C. waste pipe with fitting arrangement etc.complete as directed by Engineer in charge.( Make shall conform to manufacturer\"s Green product and shall got approved fromthe Engineer In Charge.) |
| 189 | Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidngcoupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. |
| 190 | Unloading, Storing, Safe keeping, shifting, installing, testing & commissioning of Clinical Stainless Steel Scrub Station or sink consisting of single bowl with single/ double drain board with necessary supporting brackets including providing C.P.brass elbow action tap for cold water / hot water, C.P.brass waste bottle trap, PVC waste pipe complete. |
| 191 | Domestic Water HeaterUnloading, Storing, Safe keeping, shifting, installing, testing & commissioning of in position Coloured vertical pressure type Water Heaters (Geysers) wall mounting type of following capacities with necessary supporting brackets including providing all inlet,outlet, overflow vent connections with necessary valves /cocks complete. |
| 192 | Providing and fixing C.P. BIB cock with wall flange of approved makeincluding necessary sockets/ union nut etc. complete. |
| 193 | Providing and fixing C.P.Handshower (health faucet) 1m.PVC tube with wall hook jaquar make with flexible tube having wall hook withapprovedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 194 | Providing and fixingC.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental ( for geyser including necessary sockets/union nut etc. complete. |
| 195 | Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc.complete |
| 196 | Providing and fixing C.P. sink cock with raised J\" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete.\" |
| 197 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 198 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVCpipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 199 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVCpipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 200 | Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVCpipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 201 | Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 202 | Providing and fixing Brass/Bronze/S.S. Ball valve with pressure rating of approved make with material and labour etc all complete as per drawings, specifications and directions of the engineer-in-charge. |
| 203 | 25 mm |
| 204 | 32 mm |
| 205 | 40 mm |
| 206 | 50 mm |
| 207 | UPVC PipeuPVC (Unplasticized Poly Vinyl Chloride) water supply pipes with Schedule 40 Pipe and schedule 40 fittings. Pipes shall be joined using solvent welded uPVC sch-40 fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, bushings etc. including transition fittings (connection between uPVC & metal pipe/GI) i.e. Brass Adapters (both Male & Female threaded) conforming to ASTM D-2467. with only uPVC solvent cement conforming to ASTM D-2564.All termination points for installation of faucets shall have brass termination fittings.Installation shall be to as per Technical Manual of manufacturer of pipes & fittings.Cost shall be inclusive of (a) wall cutting, chasing & making good as same as before, Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc, as per specification. Exposed pipes to be painted of legends with direction arrow. (Vertical Shaft D/Takes & internal piping) 65 mm dia |
| 208 | Providing and laying in walls/ceilings/floors 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 12.43 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 209 | Providing & fixing heat insulation by wrapping the pipes with glass wool/asbestos fibre rope or tape/videoflex 15 mm as directed by Engineer in charge. |
| 210 | Providing, laying and fixing P.V.C. pipe of 32mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or asdirected etc. complete |
| 211 | Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc.ncluding necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 212 | Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees, reducers, clamps, etc.including necessary excavation, trench filling etc. complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 213 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete |
| 214 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc complete. |
| 215 | Providing, fixing, jointing, tetsing & commissioning of Floor PVC cleanout plug with suitable inlet keys for opening, male threaded joint with Socket caulked to soil or waste pipe as required 75 mm dia |
| 216 | 110 mm dia |
| 217 | Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece ofUPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) |
| 218 | Providing and fixing Multi floor trap of 110x110mm with jali50 mm minimum seal suitable for kitchen all complete. |
| 219 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 220 | Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 221 | Constructing water tight brick masonry Inspection chamber with first class bricksin cement mortar 1:6 (1cement :6 coarse sand), R.C.C. top slab with 1:2:4 mix (1cement :2coarse sand :4 graded stone aggregate 20mm nominal size). Foundation concrete 150mm thick 1:4:8 (1cement :4 coarse sand :8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement plaster 1:3 (1cement :3 coarse sand) finished with a floating coat of neat cement and making channel in cement concrete 1:3:6 mix,M.S. foot rests including fixing in 20 x 20 x 10cm cement conc. blocksneatly finished, complete as per standard design and approved drawings.(Price shall include the cost of excavation, back filling, disposal of suplus earth dewatering & water proofing of manholes as directed at site & other associated civil works). Inside size 900mm x 800mm from 0.6 to 0.9m deep for sewer chamber. Chamber cover of FRP Capable of taking 2 wheeler / light vehical load (5MT). |
| 222 | Inside size 900mm Dia from 0.9 to 1.65m deep for sewer chamber. Chamber cover ofFRP Capable of taking fire engine movement load (40MT) |
| 223 | Inside size 1200mm Dia from 1.65 to 2.3 m deep for sewer chamber. Chamber cover of FRP Capable of taking fire engine movement load (40MT) |
| 224 | Supply, Unloading, Storing, Safe keeping, shifting, installing, testing & commissioning of Anti Rodent Double Walled Corrugated Pipe (PE/PP) for storm water drain pipe installation confirming to IS: 16098, Stiffnes SN4, cut to required lengths including coupler, Tee, Bend to correct levels below ground in trenches upto required depth including excavation in all kind of soil including (hard Rock) dewatering, refilling,watering, ramming and removing the surplus excavated material and making good the same complete as required for sewage drain. Making proper connection with coupler joint of required depth as per manufacturer. Cutting, chases / holes in walls / slab to the satisfaction of the project manager / consultants and making good the same after pipes have been duly laid and testing complete 160mm dia |
| 225 | 200mm dia |
| 226 | 250mm dia |
| 227 | Supply, Unloading, Storing, Safe keeping, shifting, installing, testing & commissioning of socketed and spigotted RCC pipes (HUME pipe) (NP2 Class) confirming IS: 458 jointed with rubber rings & laid to correct levels below ground in trenches upto required depth including excavation in all kind of soil including (hard Rock) dewatering, refilling,watering, ramming and removing the surplus excavated material and making good the same complete as required for rain water dispossal. 160mm dia |
| 228 | 200mm dia |
| 229 | 250 mm dia |
| 230 | Constructing water tight brick masonry catchbasin with first class bricks in cement mortar 1:6 (1cement :6 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement :2coarse sand :4 graded stone aggregate 20mm nominal size). Foundation concrete 150mm thick 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement plaster 1:3 (1cement :3 coarse sand) finished with a floating coat of neat cement and making channel in cement concrete 1:3:6 mix neatly finished, complete as per standard design and approved drawings including manhole cover as specified below. (Price shall include the cost of excavation, back filling, disposal of suplus earth dewatering & water proofing of manholes as directed at site & other associated civil works).Internal size 600 x 600 mm upto 0.9 m deep with perforated grating of SFRCto take weight of 4 wheeler. |
| 231 | Internal size 800 x 800 mm upto 1.5 m deep with SFRC grating ofto take weight of fire engine. |
| 232 | Internal size 1000 x 1000 mm upto 2.0 m deep with SFRC grating ofto take weight of fire engine. |
| 233 | Providing & Constructing surface drain in basement/open ground with 9\" burnt brick masonry plastered on both sides with 3/4\" thick in cement morter 1:3 including 18\" dia glazed stoneware channel at bottom fixed in cement concrete 1:4:8 bedding given required slope, curing, necessary excavation, refilling the sides etc. complete including 50mm thick grating as per design etc. 450mm wide |
| 234 | 600mm wide |
| 235 | 900 mm wide |
| 236 | Supply, Unloading, Storing, Safe keeping, shifting, installing, testing & commissioning off in position 100mm dia gully trap in brick masonry chamber of 300mm x 300mm including embedding the gully trap in cement concrete 1:2:4, (1:6) plastering, curing, effecting necessary connections and providing bitumastic painted special Chamber cover of THERMODRAIN FRP Capable of taking 2 wheeler / light vehical load (5MT). |
| 237 | SITC of Pressure SandFilter with necessary accessories complete with frontal piping,valves,suitable supports for mounting pressure gauges,orifice plates. The filter shall be made of MSEP vessel with necessary accessories. The cost of filter shall also include initial charge of under bed with pebbles & Coarse Sand media to suit the requirement etc.complete as per standards. |
| 238 | Installation |
| 239 | SITC of Activated Carbon Filter with necessary accessories complete with frontal piping,valves,suitable supports for mounting pressure gauges,orifice plates. The filter shall be made of MSEP vessel with necessary accessories. The cost of filter shall also include initial charge of under bed with pebbles & Activated carbon filter media to suit the requirement etc.complete as per standards. |
| 240 | Installation |
| 241 | SITC of piping sytem with UPVC SCH-40 pipes fittings,required valves and instruments for processing in treatment plant. The scope includes cutting the pipes to required lengths, jointing the pipes using solvent joint type.And necessary chasing the walls / floors, making holes, clamping to walls and restoring the same to original conditions etc., complete all as specified and directed and as per manufacturer\"s specification. |
| 242 | Installation |
| 243 | SITC of delivery, testing, commissioning of Vertical Multi stageCentrifugal Pump with suitable capacity 415V, 3-phase,50Hz motor and coupling with base frame having discharge capacity of 15.0 Cum/Hr against total head of 25m from all causes, with common starter pannel, each starter consists of suitable MPCB, Contactor, Overload relay, Single Phase Preventor, Push buttons, LED on indicators, all in comings in Weather Proof box (IP55) and necessary suitable copper cables from starter panel to pump (Appx.20Mtrs/each pump) etc. Pumps shall be IE-3 Class rated. complete with necessary accessories.(Pump for water treatment plant) . The scope includes auto on/off water level controller for pump. |
| 244 | Installation |
| 245 | Supply, installation, Testing & commissioningof Reverse Osmosis Plant(RO) , the features of the plant is , Plant skid made fromMS (Powder coated) Pre filtration in FRP vessel. Pre filter with sediment and housing.High pressure pumps (Rotary vane type/ vertical) Anti scalene dosing pump. Membrane housing Stainless Steel) High pressure pump; Low pressure control switch. Full electronic/ MCB panel with Auto water level sensor. CPVC Piping. Membrane cleaning system. Fully automatic with TDS meter, flow meter & pressure gauge.complete with necessary accessories. (for Dyalisys, drinking and hospital other requirements) Capacity :2000 LPH/Hour. |
| 246 | Supply & installation of Stainless Steel (SS316 food grade 1.6-2mm thickness)water storage tank with required necessary accessories etc,complete with necessary accessories. |
| 247 | Installation |
| 248 | Supply, installation, Testing & commissioningof UV - sterilization plant .The plant consists of Rinsing set for UV-disinfection plants for cleaning of deposits on quartz and internal surface of protective tube. (Suitable as per system1000LPH) |
| 249 | Installation |
| 250 | Supply, installation, Testing & commissioningof Reverse Osmosis Plant(RO) , the features of the plant is , Plant skid made fromMS (Powder coated) Pre filtration in SS vessel. Pre filter with sediment and housing.High pressure pumps (Rotary vane type/ vertical) Anti scalene dosing pump. Membrane housing Stainless Steel) High pressure pump; Low pressure control switch. Full electronic/ MCB panel with Auto water level sensor. CPVC Piping. Membrane cleaning system. Fully automatic with TDS meter, flow meter & pressure gauge.complete with necessary accessories. (for Dyalisys requirements) |
| 251 | Installation |
| 252 | Supply & installation of Stainless Steel (SS 316-food grade 1.6-2mm thick)water storage tank with required necessary accessories etc,complete with necessary accessories. |
| 253 | Installation |
| 254 | Supply, delivery, testing, commissioning ofcentrifugal pump with suitable capacity 230V, 1-phase,50Hz motor and coupling with base frame having discharge capacity of 1.0 Cum/Hr against total head of 25m from all causes, without starter, complete as required.(RO water re-circulation pump). The scope includes timer controller. Prefered Make : Grundfos |
| 255 | Installation |
| 256 | Supply,Installation,Testing & Commissioning of Sewage Treatment Plant with MBR technology |
| 257 | Installation |
| 258 | Supply,Installation,Testing & Commissioning of Effluent Treatment Plant. ETP to be newly constructed |
| 259 | Installation |
| 260 | Supply and Installation, testing & commissioning |
| 261 | Supply Of Above Complete Set and Installation, testing & commissioning |
| 262 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 263 | Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) alongwith necessary accessories complete as per specification no. FF-FFA/HV |
| 264 | 13-8-1 Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL |
| 265 | Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) |
| 266 | Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF- FFA/NZ |
| 267 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary ,fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 268 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 269 | Providing and fixing ball valves 20mm for connection First Aid Hose Reel Drum at eachfloor level .25 mm dia. |
| 270 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 271 | Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 272 | Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 273 | Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 274 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 275 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 276 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 277 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 278 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 279 | Supplying, erecting, testing and commissioning of concealed quartzoid bulb sprinkler, 15 mm (½\") dia quartzoid bulb. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR/CON |
| 280 | Supplying, erecting, testing and commissioning of Upright/ Pendent quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR./UP |
| 281 | Supplying, erecting, testing and commissioning of horizontal sidewall quartzoid bulb sprinkler, 15 mm (½\") dia quartzoid bulb. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR/SS |
| 282 | Supplying, erecting, testing and commissioning of concealed quartzoid bulb sprinkler, 15 mm (½\") dia quartzoid bulb. NBCM Body chrome finished, 79º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR/CON |
| 283 | Supplying erecting, testing and commissioning of sprinkler flexible pipe of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of 1000 mm size (UL Listed) complete as required as per specification no. FF-SPR/FHP |
| 284 | Supply, Installation, Testing & Commissioning of 25 mm dia SS test and drain valve connected to drain line. |
| 285 | Supply, Installation, Testing & Commissioning of electrically operated flow indicating switches in sprinkler branch line on each zone of each floor (Wiring from switches to panel by others) |
| 286 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 287 | 13-8-1 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 288 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 289 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 290 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 291 | Supply, Installation, Testing & Commissioning of ISI marked portable fire extinguisher of ABC type (gas pressure) 6kg capacity as per IS:13849 complete in all respects including initial fill. |
| 292 | Supply, Installation , testing, commissioning and handing over of Sand Buckets as per Tender Specifications. 16mm round bar and 25x25d steel angles of 3mm thickness to be considered.(Two Sand Buckets to be kept along with stand ) |
| 293 | TABLE:-L2700xW1050xW1050xD600xH750mm |
| 294 | TABLE:-L4600xW2600xW1200xD600xH750mm |
| 295 | CHAIR Libro MBBack Height - Medium BackBack Finish - Mesh with adjustable lumbar supportBack Frame - Black ColorSeat Finish - Fabric - BlackSeat Height Adjustment - PneumaticMechanism - Synchronized TiltBack Tilt Lock - Upright PositionBack Tilt Tension - AdjustableArmrests Type - 1D Height AdjustableArmpads Type - MetalBase Type - 5-Star in Nylone BaseWarranty : 3 years from the date of invoice Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD ,Green Guard product specific certificate issued by UL Environment . |
| 296 | TABLE :-W1500X D750 XH750MM WITH SIDE COMBO :-W900XD450XH750MM |
| 297 | BACK STORAGE :-W1200xD450xH750mm Providing & Supplying HNI Make Cabin Tablewith Main Table side combostorageThe Worktop is made of 25mm thick Prelaminated particle board with 2 mm thick PVC Lipping on the edges. The worktop is supported on U Shape Metal Legs 50mm x 50mm , powder coated understructure with Laminate Modesty panel. The Metal legs are connected by Metal Beams for stability and . The Table tops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . Colour as per direction of Engineer in Charge. Laminate pedestal unit having Dimension 400mm W x 450mm D x 621Ht and shall consist of One pencil tray, 2 drawers and one filing box.It is made of 18mm prelaminated particle board . It shall be provided with 2 lockable and two free twin wheeled castors.The pedestals shall have central locking mechanism.It has roller slide mechanism for 2 Drawers and Ball bearing slide for 1 Filng Unit.The pencil tray shall be made of2mm moulded HIPS and shall be fitted inside the first drawer.It should freely slide in horizontal direction.The pencil tray shall have necessary compartments (Miniumum 3 compartments) for keeping stationary items.Pedestal is without handle and shall have side champhered edges for operating. |
| 298 | FLUENCE HB (with Headrest)Back Height - High BackBack Finish - Mesh with adjustable lumbar supportBack Frame - Black ColorSeat Finish - Fabric ( Black)Seat Height Adjustment - PneumaticMechanism - Synchronized TiltBack Tilt Lock - Upright PositionBack Tilt Tension - AdjustableArmrests Type - 2D Height AdjustableArmpads Type - PolyurethaneBase Type - 5-Star in Black nylon WARRANTY: 10 Years from the date of invoiceCertifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD ,Green Guard product specific certificate issued by UL Environment . |
| 299 | VISITOR CHAIR QUIP MBBack Height - Medium BackBack Finish - Mesh with adjustable lumbar supportBack Frame - Black ColorSeat Finish - FabricSeat Height Adjustment - PneumaticMechanism - Synchronized TiltBack Tilt Lock - Upright PositionBack Tilt Tension - AdjustableArmrests Type - 1D Height AdjustableArmpads Type - PolyurethaneBase Type - 5-Star in Nylone Base Warranty : 5 years from the date of invoice Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD ,Green Guard product specific certificate issued by UL Environment . |
| 300 | STORAGE :-W900xD450xH2100mm Providing and placing HNI Trent Prelaminated Particle Board storage with openable doors of 2100mm (ht), made up of 18mm thick prelaminated particle board with PVC edge banding and locking arrangement.Storage body is made of 18mm thick pre laminated partical Board conforming to IS : 12823 Interior Grade, The back of the unit is made from 18mm prelaminated board. All the exposed edges are with 2mm PVC egde Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. The top, side and hinged shutters are sealed with 2mm thick PVC edge banding.Storage has adjustable shelves inside and cam lock, tower bolt and locking strips. The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Hettich/Ebco. Storage has Brushed SS finish handles and lock. Prelam storage unit of 2100 mm ht and 450mm depth stackable full ht storage. Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD . Warranty 5 years . TEACHING ROOM Table :-W1500xD750xH750mm |
| 301 | Providing and Supplying HNI Make Office Table . Worktop is made of 25mm thick PLPB of Grade II, Type IIconforming to IS:12823: 1990 and having 2mm thick pvc edge lipping, Understructure is made of 18mm thick PLPB of Grade II, Type IIconforming to IS:12823: 1990 and having 2mm thick pvc edge lipping .Three no Drawer is built into the table.The Drawers have lock and each drawer is provided with Pull out Handle. Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD . Warranty 5 years . GROUP COUNSELLING |
| 302 | Seat is made of Injection molded polypropylene. Seat is attached to the frame by the back attachment and with two steel Pal-nuts . Backrest is also made of Injection molded polypropylene. Attached to the frame with two metal clips. Contains a contoured handle opening at the top for easy lifting and stacking.Chair Frame Construction - Welded construction made primarily of 7/16\" diameter steel wire (solid) bent to shape on a CNC wire bender. A 7-gauge steel seat strap, ribbed for added strength, supports the front of the seat and a 7/16\" contoured steel rod joins the front legs for strength. Frame Finish - Bright chrome plated finish with duplex (semi-bright) nickel, bright nickel and chrome applied. Nickel provides corrosion resistance. Tablet arm is designed for easy attachment and removal. Brackets on the tablet arm just hook/snap on the chair frame. Tablet surface is hinged for easy access into the chair. Tablet frame is a welded construction made of 7/16\" diameter steel wire bent to shape and two 11-gauge brackets. Finish is bright chrome only. Tablet surface has a plywood core with a highpressure laminate surface on the top and a backer sheet on the back. The edges are round with a clear lacquer finish and 5/8\" overall thickness. Chairs are non-stacking when tablet arms are attached. Warranty - 5 Years . Makes IMAGO |
| 303 | Providing and supplying Reception Desk having1185mm Height . It has 25mm thick Worktop and Gable Ends made of pre Laminated Particle Board sealed with PVC Edge Banding. Front and Modesty Panel are 18mm thick Pre Laminated ParticleBoard Sealed with PVC EdgeBanding.. The Counter Top is 25 mm Thick Postformed ParticleBoard.Unit has One Pull out drawer with Lock and Handle. Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD . Warranty 5 years . |
| 304 | Libro MBBack Height - Medium BackBack Finish - Mesh with adjustable lumbar supportBack Frame - Black ColorSeat Finish - Fabric - BlackSeat Height Adjustment - PneumaticMechanism - Synchronized TiltBack Tilt Lock - Upright PositionBack Tilt Tension - AdjustableArmrests Type - 1D Height AdjustableArmpads Type - MetalBase Type - 5-Star in Nylone BaseWarranty : 3 years from the date of invoice Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD ,Green Guard product specific certificate issued by UL Environment .CENTRE TABLE :-W900xD600xH400mm |
| 305 | Supply and placing centre table in position with sizes 400mm(H)with top made of 10mm thick glass top supported on SS Studs on understructure ofPrelaminated Particle Board. The Table shall have another shelf at lower level The work shall be carried out as per the instructions received from engineer-incharge. Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD . Warranty 5 years . CORNER TABLEW450xD450xH400mm |
| 306 | Providing & Fixing of Table having dimension 400mm Ht made of 18mm thick prelaminated particle board .The top is 10mm thick Glass supported on 4 nos. SS Studswith verticals also made of 18mm Particle board.The table has a shelf of 450mm L x 450mm W under the main top. All edges are sealed with 2 mm thick PVC Lipping. The above furniture should be as per specification and sample approved by client. Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD . Warranty 5 years . 1 SEATER SOFA |
| 307 | 1 SEATER SOFA |
| 308 | Providing & Fixing of sofa . The inside frame is made of seasoned wood and has antitermite treatment. The seat and back are made of foam and is finished in leatherite upholestry. The Frame base has Webbing for Supporting the Cushions. The Complete Sofa Body has Polyurethane Foam in desired shape. The Sofa is supported on Metal Chrome Plated Legs. Leatherite colour and type as per directions of Engineer in Charge TABLE:-W1800XD600XH750mm WITH PEDESTAL |
| 309 | Providing & Supplying HNI Make Cabin Tablewith Main Table and laminate pedestal unit .The Worktop is made of 25mm thick Prelaminated particle board with 2 mm thick PVC Lipping on the edges. The worktop is supported on open Metal Legs 50mm x 50mm , powder coated understructure with Laminate Modesty panel. The Metal legs are connected by Metal Beams for stability and . The Table tops should have metal inserts on underside for modularity. The screw used should be blunt headed and not sharp headed for metal to metal coupling . 3 drawer pedestal unit has castors and pedestal unit has size400mm L x 450mm D x 680mm Ht made up of 18mm thk. Prelaminated Particle Board Caracass having central locking system . 2 Drawers are with roller slide mechanism and Filing Unit is with Ball bearingslides.Colour as per direction of Engineer in Charge. Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD . Warranty 5 years . |
| 310 | Libro MBBack Height - Medium BackBack Finish - Mesh with adjustable lumbar supportBack Frame - Black ColorSeat Finish - Fabric - BlackSeat Height Adjustment - PneumaticMechanism - Synchronized TiltBack Tilt Lock - Upright PositionBack Tilt Tension - AdjustableArmrests Type - 1D Height AdjustableArmpads Type - MetalBase Type - 5-Star in Nylone BaseWarranty : 3 years from the date of invoice Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD ,Green Guard product specific certificate issued by UL Environment . |
| 311 | Providing and Supplying round meeting table withsize as mentioned below . The understructure is made of steel plate 500mm dia. The pole connecting base to table top is made of extruded aluminium pole . The top is made of 25mm thick Prelaminated particle boardwith 2mm PVC lipping . The worktop has metal inserts on the underside for modularity . The understructure is powder coated.WARRANTY: 5 Years from the date of invoice . Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD ,Green Guard product specific certificate issued by UL Environment . Warranty 5 years . |
| 312 | Seat is made of Injection molded polypropylene. Seat is attached to the frame by the back attachment and with two steel Pal-nuts . Backrest is also made of Injection molded polypropylene. Attached to the frame with two metal clips. Contains a contoured handle opening at the top for easy lifting and stacking.Chair Frame Construction - Welded construction made primarily of 7/16\" diameter steel wire (solid) bent to shape on a CNC wire bender. A 7-gauge steel seat strap, ribbed for added strength, supports the front of the seat and a 7/16\" contoured steel rod joins the front legs for strength.Frame Finish - Bright chrome plated finish with duplex (semi-bright) nickel, bright nickel and chrome applied. Nickel provides corrosion resistance. Warranty 5 years . |
| 313 | Providing and Supplying HNI Make Office Table . Worktop is made of 25mm thick PLPB of Grade II, Type IIconforming to IS:12823: 1990 and having 2mm thick pvc edge lipping, Understructure is made of 18mm thick PLPB of Grade II, Type IIconforming to IS:12823: 1990 and having 2mm thick pvc edge lipping .Three no Drawer is built into the table.The Drawers have lock and each drawer is provided with Pull out Handle. Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD . Warranty 5 years . |
| 314 | Back Height - High Back with HeadrestBack Finish - Mesh with adjustable lumbar supportBack Frame - Black ColorSeat Finish - Fabric ( Black)Seat Height Adjustment - PneumaticMechanism - Synchronized TiltBack Tilt Lock - Upright PositionBack Tilt Tension - AdjustableArmrests Type - 1D Height AdjustableArmpads Type - PolyurethaneBase Type - 5-Star in Black nylon WARRANTY: 5 Years from the date of invoice Certifications - ISO 9001 - 2015 ,14001- 2015 ,45001-2018 , BIS and BIFMA Complaint member , BIFMA GOLD ,Green Guard product specific certificate issued by UL Environment . |
| 315 | Chair |
| 316 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 317 | Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 318 | Supplyof20WLED battenWHPVC (5700K to 6000K)CRl>70%Lumenefficacy> 100 Lumen per Supplying and erecting GLS Lamp.20-40W |
| 319 | Supplying and erectingEnergy Saving Ceiling fan of 3 star rating as per BEE 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 320 | Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overheat protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation |
| 321 | Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. |
| 322 | Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 323 | Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W. |
| 324 | Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface. |
| 325 | Supplying & erecting triplepoleandneutraldistribution board(TPNDB), SP/TPMCBstotal4 ways/12 Poles,with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no.SW-MCBDB. |
| 326 | Supplying & erecting triplepoleandneutraldistribution board(TPNDB), SP/TPMCBstotal8 ways/24 Poles,with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no.SW-MCBDB. |
| 327 | Supplying & erecting triplepoleandneutraldistribution board(TPNDB), SP/TPMCBstotal12 ways/36 Poles,with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no.SW-MCBDB. |
| 328 | Supplying & erecting triplepole andneutraldistribution board(TPNDB), SPMCB of 4ways/phase (12 poles),with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GIframe (horizontal busbar type) as per specification no. SW-MCBDB. |
| 329 | Supplying & erecting triplepole andneutraldistribution board(TPNDB), SPMCB of 8 ways/phase (24 poles),with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GIframe (horizontal busbar type) as per specification no. SW-MCBDB. |
| 330 | Supplying & erecting triplepole andneutraldistribution board(TPNDB), SPMCB of 12 ways/phase (36 poles),with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GIframe (horizontal busbar type) as per specification no. SW-MCBDB. |
| 331 | Supplying and erecting singlepole andneutraldistribution board(SPNDB), with 2ways for incoming and4 ways (4 poles)for outgoing SP MCBs,with door, 1.2mm thickness surface/flush mounted, IP 43 Protectionon provided iron/GI frame as per specification no. SW-MCBDB |
| 332 | Supplying and erecting singlepole andneutraldistribution board(SPNDB), with 2ways for incoming and6 ways (6 poles)for outgoing SP MCBs,with door, 1.2mm thickness surface/flush mounted, IP 43 Protectionon provided iron/GI frame as per specification no. SW-MCBDB |
| 333 | Supplying and erecting singlepole andneutraldistribution board(SPNDB), with 2ways for incoming and8 ways (8 poles)for outgoing SP MCBs,with door, 1.2mm thickness surface/flush mounted, IP 43 Protectionon provided iron/GI frame as per specification no. SW-MCBDB |
| 334 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with ratedshort - circuit breaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB |
| 335 | Supplying, erecting & marking DP MCB 6A to 32A, C-serieswith ratedshort - circuitbreaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB |
| 336 | Supplying, erecting&markingTPMCB6A to32A,withrated short -circuitbreaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB |
| 337 | Supplying, erecting & marking TPMCB40A to63A, with rated short-circuitbreaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB |
| 338 | Supplying, erecting&markingFPMCB6Ato32A,withrated short -circuitbreaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB |
| 339 | Supplying, erecting &marking FPMCB40A to63A, with rated short-circuit breaking capacity (Icn)10kA in provided distribution board as per specification no.SW-MCB |
| 340 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mAsensitivitywithearthleakagetrip indicationcompleteasper specification no. SW-RCCB |
| 341 | Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mAsensitivitywithearthleakagetrip indicationcompleteasper specification no. SW-RCCB. |
| 342 | Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mAsensitivitywithearthleakagetrip indicationcompleteasper specification no. SW-RCCB. |
| 343 | Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mAsensitivitywithearthleakagetrip indicationcompleteasper specification no. SW-RCCB. |
| 344 | Supplying, fixing and commissioning 2 pole RCBO up to 25A, with overcurrent, rated short-circuitbreakingcapacity(10kA)and earth leakage protection,with 30/100/300mA sensitivity and shortcircuit and earth leakage trip indication as per specification no SW-RCBO. |
| 345 | Supplying, fixing and commissioning 4 pole RCBO up to 32/40A, with overcurrent, rated short-circuitbreakingcapacity(10kA)and earth leakage protection,with 30/100/300mA sensitivity and shortcircuit and earth leakage trip indication as per specification no SW-RCBO. |
| 346 | Supplying, fixing and commissioning 4 pole RCBO up to 63A, with overcurrent, rated short-circuitbreakingcapacity(10kA)and earth leakage protection,with 30/100/300mA sensitivity and shortcircuit and earth leakage trip indication as per specification no SW-RCBO. |
| 347 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitableforDPMCB/TPMCB/FPMCB/RCCB/RCBOcompleteerectedonprovided angle iron/GI frame |
| 348 | Supplying &erecting ONLOADchange overswitch4 Pole,415V,160A,open execution having staggered termination, phase barrier, shroud termination and terminal coveralong withauxiliary contactsandready toupgradewithfuse protectionkit, operationalcurrentcategory AC23A complying toIS/IEC60947-3 Part-1/3as perspecification no. SW-SWR/COS. |
| 349 | Providing & erecting 4 PoleMCCB,415V, upto100A, rated short-circuit breaking capacity 25 kA(Ics=100% ofIcu),adjustable thermal(overload) setting andfixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 350 | Providing & erecting 4 PoleMCCB,415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu),adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 351 | S & E OF cu Link of 16sqmm with copper lugs for connecting the switchgear to busbar |
| 352 | S & E OF cu Link of 32sqmm with copper lugs for connecting the switchgear to busbar |
| 353 | S & E OF Busbar connectors with seprator in each pole, Mounting on connector strips, 4pole from 16 to 50 sqmm for connecting the switchgear to the outgoing cable equivalent to connectwell |
| 354 | Supplying,erecting, testing &commisioningmetal workinCRCAsheet includingIron work for supports with fabrication ofboxes, panelboards, etc including cutting, bending, drilling,welding, riveting, treatedwithanti-rust treatment and paintedwith one coat of red lead paint and 2 coats of enamel paint or powder coating complete as per specification no. CP/SH/CR |
| 355 | Supplying,erecting,testing&commisioning GIsheet1.25mm(18SWG) having zinc coating of 350 micronswithgalvanizationprocess compliance toIS 2629:1985tobeused for fabrication ofboxespanelboards etc. including cutting,bending,drilling, welding, riveting etc. and paintingwithone coat ofred lead paintand 2 coats ofenamelpaintas per specificationno. CP/SH/CR |
| 356 | Supplyinganderectingiron work, sheet metal work consisting of MS sheets, varioussectionsofiron,plates, chequered plates,rods,bars, MS pipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerected attheposition with necessarymaterialsdulypainted with one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the site engineer. |
| 357 | Supplyinganderectingaluminiumstrip of required sizes used for earthing or any other purpose with necessaryaluminiumclampsfixed on wall paintedwith bituminous paint as per specification no EA-EP. |
| 358 | Supplying and erecting copperstrip of requiredsizes used for earthing on wall and/oranyotherpurpose withnecessary aluminium clamps fixedonwall painted with bituminous paint with joints required as per specification no EA-EP. |
| 359 | Supplying and erecting GI strip of required size used for earthing on wall and/or anyotherpurposewithnecessaryGIclampsfixedonwallpainted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 360 | Supplying and erecting annealed bare copper earth conductor of required sizes used forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews complete. |
| 361 | Supplying and erecting GI earth conductorof required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 362 | Supplying,erecting &terminating FR-XLPEinsulated galvanised steel formed wire armoured(Strip) cable, 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL |
| 363 | Supplying, erecting & terminating FR-XLPEinsulated, galvanised steel formed wire armoured (Strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 364 | Supplying, erecting & terminating FR-XLPE insulated, galvanised steel formed wire armoured(Strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 365 | Supplying, erecting & terminating FR-XLPE insulated, galvanised steel formed wire armoured(Strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 366 | Supplying, erecting & terminating FR-XLPE insulated, galvanised steel formed wire armoured(Strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 367 | Supplying, erecting & terminating FR-XLPE insulated, galvanised steel formed wire armoured(Strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 368 | Supplying,erecting&terminatingFRXLPE insulated, galvanised steel formedwirearmoured (strip)cable1100 V, 4core 10sq.mm.copper conductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU |
| 369 | Supplying, erecting & terminating FR-XLPE insulated, galvanised steel formed wire armoured(Strip) cable 1100 V, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 370 | Supplying, erecting & terminating FR-XLPE insulated, galvanised steel formed wire armoured(Strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 371 | Supplying, erecting & terminating FR-XLPE insulated, galvanised steel formed wire armoured(Strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 372 | Supplying & erecting mains with 3x6 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW (DB to First Switch Board OR First Switch Board to Second Switch Board) |
| 373 | Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 374 | Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW |
| 375 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 376 | Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 377 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. |
| 378 | Providing & erecting hot dippedgalvanised perforated type cable tray manufactured from 16SWG GIsheet of 500 mmwidth& 75 mm height complete with necessary coupler plates & hardware. |
| 379 | Providing & erecting hot dippedgalvanised perforated type cable tray manufactured from 16SWG GIsheet of 400 mmwidth& 75 mm height complete with necessary coupler plates & hardware. |
| 380 | Providing & erecting hot dippedgalvanised perforated type cable tray manufactured from 16SWG GIsheet of 300 mmwidth& 75 mm height complete with necessary coupler plates & hardware. |
| 381 | Providing & erecting hot dippedgalvanised perforated type cable tray manufactured from 16SWG GIsheet of 200 mmwidth& 75 mm height complete with necessary coupler plates & hardware. |
| 382 | Providing & erecting hot dippedgalvanised perforated type cable tray manufactured from 16SWG GIsheet of 150 mmwidth& 75 mm height complete with necessary coupler plates & hardware. |
| 383 | Providing&erectinghotdipped galvanisedcoversuitablefor ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 384 | Providing&erectinghotdipped galvanisedcoversuitablefor ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 200 mm width & 20 mm height complete with necessary hardware. |
| 385 | Providing&erectinghotdipped galvanisedcoversuitablefor ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 300 mm width & 20 mm height complete with necessary hardware. |
| 386 | Providing&erectinghotdipped galvanisedcoversuitablefor ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 400 mm width & 20 mm height complete with necessary hardware. |
| 387 | Providing&erectinghotdipped galvanisedcoversuitablefor ladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 500 mm width & 20 mm height complete with necessary hardware. |
| 388 | Makingtrenchin Hardmurum/Tar road having 0.75m depth and minimum 0.3m widthfor laying provided cables up to voltage level1.1kV cable complete as per specification no. CW-EXN-CTR |
| 389 | Supplying &laying(including excavation) halfround reinforced cement concretepipe of NP-2 class of 250 mm diameter in proper line, level and slope includingprovidingandfixingcollarsincement mortar1:2andcuringetc. complete. |
| 390 | Supplying, erecting, testing & commissioning of 2kVA capacity on linepure sine wave,PWM,IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase outputcompletewithall protections as per specificationno. AP- UPS(Without batteries) |
| 391 | Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete |
| 392 | Point wiring for light/bell concealedtype in min 20 mm HMS PVC conduit with1.5 sq.mm. (2+1E) FRLSH grade copper wires,modulartypeswitch, earthing and requiredaccessories as per specification no. WG-PW/CW |
| 393 | Pointwiring forceilingfan concealedtypeinmin20 mm HMSPVC conduitwith 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modulartype switch,earthing and requiredaccessories as per specification no. WG-PW/CW |
| 394 | Secondary pointwiring for additional light/bell pointinmin20mm PVC conduitwith1.5sq.mm(2+1E)FRLSH grade copper wirewithrequired accessories as per specification no. WG-PW/SW |
| 395 | Wiring for plug on board withswitch socket surface/concealed type, copper wiring and earthing and with modularaccessories as per specification no.WG- PW/CW |
| 396 | Supplying anderecting luminous / modulartype call bell indicatorwith plasticbody, heavy duty coil and indicator lamp working on 230V A.C. supply withresettingarrangement completeerectedondoublewooden / sunmica board. |
| 397 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 398 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. |
| 399 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 400 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 401 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 402 | Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. |
| 403 | Supplying and erecting16 to 32A, 10kA, DPMCB suitable to fix in 2 module of modularswitch in providedbox complete & duly concealedwith necessary material and connected. |
| 404 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 405 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 406 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 407 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 408 | Supplying and erecting unbreakable concealedtype modularswitch box with doublemountingplatefor12moduleduly flushedtowallwithrequired chiselling and finishing with cement mortar / POP as per required to match the background. |
| 409 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 410 | Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring connections complete. |
| 411 | Providing & Fixing of printed instructionchartfor (with minimum700 x1000 mm in size) treating persons suffering from electric shock, printedin English & Marathi and duly laminated complete. |
| 412 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete. |
| 413 | Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 414 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV |
| 415 | Dismantling the existinglight,fan,bell, clock,independent plugpoint, wiring includingcircuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW |
| 416 | Dismantling the existingaluminium/copper mains, sub-mainswiring upto 10 sq.mm. alongwithaccessoriesetc. completeasperspecificationno. DM/PW |
| 417 | Dismantling of existing fluorescent fittings of any type & size. |
| 418 | Dismantling the existing ceiling fan /exhaust fan / cabin fan / bracketfan complete with accessories, G.I. down rod, frame etc. and making the site clear. |
| 419 | Dismantling the existing electric geyser or storage type water heater of any size along with plumbing connections and making the site clear. |
| 420 | Dismantling theexisting windowtypeair conditionerof anytypeand capacity safely without any damages and making the site clear. |
| 421 | Dismantling the existing split type air conditionerof anytype and capacity safely without any damages and making the site clear. |
| 422 | Dismantlingtheexistingswitchgears,DB, and bus bar ofanysizecomplete with/without board or angle iron frame |
| 423 | Making the site clear of dismantled DBandswitchgears by refillingtheholeswith cement mortar & finishing in an approved manner. |
| 424 | Dismantling theexistingcables of all types & size up to 10 sq mm. |
| 425 | Dismantlingtheexistingcables of all types & size above 10 sq mm up to 50 sq.mm. |
| 426 | Dismantling theexistingcables of all types & size above 50 sq mm. |
| 427 | Dismantling the existing telephone/ LAN / WAN / TV cables and wiresof all sizes along with casing-capping/ conduit complete as per specification no.WG-DM/PW |
| 428 | Painting identification number by indelible ink marker/ enamel paint on fittings/ equipment with the help of ladders if necessary by dismantling andrefitting the enclosures, tubes etc if required the same and refitting complete. |
| 429 | Supplying, installing, testing and commissioning of Addressable OpticalPhoto Smoke Detector. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have single/twin bi-colour LED for 360 deg viewing. The detector is conforming toIS 2189: 2008, 11360_1985_Reff2020_EN 54/VdS/ UL&FMapprovedwith3years equipment replacement warranty, Designed tomeet UL268, 7thEdition.FF- AFAS/SD. |
| 430 | Supplying, installing, testing andcommissioning ofintelligentaddressable thermal/heatdetector with rateofrise cumfixed temperaturethermistor complete with 0°C to 58°C temperature range, with base as required, single/twin LED’swith 360 degree view, in-built locking mechanism to check the removal and pilferage of the detector, DetectorShall conforming to IS :2175 - 1988 reaffirmed 2000, IS 15908:2021 / EN 54 / VdS / UL & FM approved with 3 FF-AFAS/HD - ROR. |
| 431 | Supplying, installing,testingandcommissioningof Addressable Multisensor/MulticriteriaPhotoThermal (Smoke+Heat) Detector. The detector shall have twin bi-colour LED for 360 deg viewing. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. This item is referred for Non-conditioning Area conforming toEN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, Designed to meet UL268, 7th Edition. |
| 432 | Supplying, erecting testingand commissioning beamsmokedetector four wiresingleendedreflectedtypewith 8 \" receiver having digital display for easy alignment, adjustable sensitivity & heater kit for transmitter/receiverand reflector with necessary connections on suitable back box. The protection range of beam detector is 5 to 100 Meters. |
| 433 | Supplying, installing, testing and commissioning remoteresponse indicators suitableto operateon 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 434 | Supplying, installing, testing andcommissioning ofaddressable manual call points( break glass type/pull station type), made of addressable break glass plastic square inshapesurface/flushmountedwith\"Break Glass\"massage embeddedontheglass, complete erected with mountingbase andrequired accessories, Module shall conform toEN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MCP. |
| 435 | Supplying, installing, testing and commissioning of AddressableSoundercum Strobe rated at minimum 75 dB @ 3m for Audible annunciation and minimum 75cd flashing at 1 Hz for visual indication. Module shall conforming to IS 2189:2008, IS 15908:2021 / EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/ S-ST |
| 436 | Supplying, installing, testing and commissioningFRLS, XLPEarmouredcable 2core 1.5sq.mm.copper conductor complete erectedonwall/ceiling complete as per specification no. CB-LT/CU |
| 437 | Supplying,installing,testing and commissioning of addressable fire control/relay modulefor AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs etc., Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 reed relays / EN 54/VdS / UL & FM approved with3years equipmentreplacementwarranty, asperspecification noFF- AFAS/CRM-FCM |
| 438 | Supplying, installing, testing and commissioning of addressable fire monitor modulefor flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitorpotential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete as required. Module shall conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays, EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MM |
| 439 | Supplying, installing, testing and commissioning ofaddressable fire isolator modulefor isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. module complete as required. Module shall conforming to IS 5051Part 2 (Sec 1 to 3) :1982, , EN54/VdS/ UL & FM approved with 3 years equipment replacement warranty, FF-AFAS/ISM |
| 440 | Supplying, installing, testing and commissioning of repeaterpanelwith suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, minimum 10\" LCD or LED display with resistive touch screen orfunctionkeys andautomaticback-light dimming andthestatusofany Fire/FaultofIntegratedFire Alarm Panels oron-boardLCDalphanumeric backlit display suitable upto640 characters with inbuilt buzzertoindicate fault/firealarm, manual control keys for silence/muteand to reset the FACP from the repeater station. Panel shall conforming to IS 15908:2021,IS 2189:2008, NFPA-72, EN 54 / VdS/FM & UL with 3 years replacement warranty FF- AFAS/RP. (Compatible with modular FAS panel from 4 loop upto 10 Loop Fire Alarm Control Panel), as per specification no FF-AFAS/RP |
| 441 | Supplying, installing, testing andcommissioning ofmicroprocessor based intelligent addressable main fire alarm panel,central processing unit with the 4 loop capacity and capable of supporting not less than 250 devices and detectors per loop, with on-board LCD alphanumeric backlit display suitable for minimum 80 characters, operating at 230 V 50 Hz - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 minutes in alarm condition, The panel shall have suitable provision for network connectivity & compatible for third partyintegration(Open Protocol to communicate) via a MODBUS/BACNET interface etc. conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL 864(10th edition) with 3 years replacement warranty and inclusive of lifetime software license validity , as per specification noFF-AFAS/CP |
| 442 | Supplying & erecting 2-Way CompactPA Wall Speaker of 32W High Fidelity sound with rated voltage 100V, power taps of 32W, 16W, 8W, Power Taps can be selected through an easily accessible rotary switch Low impedence 8?, frequency response 80-20000Hz. Weather Resistant speaker with movable mounting bracket with required screws, completeas per specification no. PA-CPAWS |
| 443 | Supplying,installing,testing&commissioning2-Wayflushmount Ceiling Speakerswith input power 20W RMS power, with power taps on 20/10/5W, 100V & 70V line, frequencyresponse 90-18000Hz, stylish metal mesh grill and plastic frame, operates on 100V linefor excellent reproductionof both speech and music,wide frequencyresponse and adjustabletweeter complete as per specification no. PA-FMCS |
| 444 | SupplyingInstalling, testing and commissioning of PA Gooseneck Microphone withBase andfrequencyresponse 50-16000Hz, 150? to200? impedence sensitivity 3to5.5mV/PA with minimum length(excludingpedestal) of 585mm(23\") long, felxible stem gooseneck condenser microphone & Heavy Duty Metal Base having on/off switch, LED indication and Suitable for 48V phantom supply as per specification no. PA-GM |
| 445 | Supplying,erecting,testing&commissioningMixerAmplifier500W RMS Power with Built-inDigitalPlayer with remoteand having 7 Mic & 3 Aux Inputs with Box Speaker/Driver Unit selector switch to each zone , stereo/mono switch, frequency response 50-15000Hz, output regulation <2dB, serprate control for USB level. The unit shall have Preamplifier and Line Output for connecting to a Booster Amplifierand for recording the programme with Resettablecircuit breaker for protectionagainst overloadand short circuit.The unitshall have speaker output range of 2?, 4?/(Low Impedence) and 70V & 100V/(High Impedence) & It can instant transfer to DC power(36V) if AC power fails. Signal to noise ratio between 60dB to 80dB. Complete as per specification no. PA-MA |
| 446 | Supplying,erecting,testingand commissioning of multistrand annealed bare copper conductor, transparent PVC insulated 2C x 2.5 sqmmspeakerwire in provided trunking/conduit etc.completeas per specification no. PA-TSPWR |
| 447 | Supplying,erecting, testingand commissioning of 2 core 2.5 sqmmcopper conductorshieldedmicrophonecable complete asper specification no. PA- SMC |
| 448 | Supplying& erectingof High definition4/5 MegapixelIP IR Bullet Camera with followingfeaturesImage Sensor:minimum1/2.8\" ProgressiveScan CMOS, VideoResolution: minimum2592 x 1520 VideoCompression : H.264,H.265 or higher,at least Threeindividuallyconfigurablestream, Frame rate : minimum25 fps at all resolutions,WDR: minimum120 dB WideDynamicRange,ONVIFprofile \"contormant, minimumIR distance:50m,Lens Type:2.8/4/6 mm Lens, fixed focal,Field of View:2.8 mm, horizontalFOV 98°, verticalFOV 72°, diagonalFOV 131° 4 mm, horizontal FOV 80°, verticalFOV 58°, diagonalFOV 104° 6 mm, horizontalFOV 51°, verticalFOV 37°, diagonalFOV 66° Lux sensitivity- minimum0.003 Lux at color, at Black & White,OLux (IR) Night VisionDistanceminimumIR -50m:Camera minimumAdjustment Angles- Pan :360°, Tilt: 90°, Rotate :360°.Power Supply: Support12VDC& PoE, IP67.Built in micro SD/SDHC/SDXCcard slot of upto 256 GB, Built in microphone. minimum Input/Output- Audioin x1, AudioOut x1, Alarmin x1, AlarmOut x1. Image Settings:Rotatemode,saturation,brightness,contrast,sharpness, gain, white balance.ImageEnhancements :Day/Night-Auto/Color/Black& White,30Digital Noise Reduction, WhiteBalance,Gain Control,Backlight Compensation,HighlightCompensation. Events:Privacy Masking,Motion detection,Scene changedetection, Face capture,Video tampering,audio exceptiondetection,Region entrancedetection, Region exiting detection. Operatingtemperature( -30 to 60° C ) |
| 449 | SITC of 4MP IP DOME CAMERA, 1/3\" CMOS image sensor, Output 4MP (2560 x 1440)@25/30fps, Max, H.265 codec high comprassion ration, Built-in IR LED, Max IR distance 30m,H.264 MJEPG,WDR-120db, SD card slot, Support max 256GB micro sd card, IP^& protection, Streams capacity 2, protection IP67,CE,ROHS |
| 450 | Supplying, installing, testing& commissioning of 64/80ChNetworkVideoRecorder (NVR), suitable connectMin. 64 IP Cameras,up to 5 MegapixelResolution,with HDMI 1/VGA1 and HDMI 2/VGA2 outputs provided,Atleast one HDMI output of 4K resolution, atleast one VGA output with outputup to 1920 × 1080,Support H.265 or higher, H.264, MJPEG,Supports Redundant Dual Power,IncomingBandwidth320 Mbpswithminimum8 SATA Hard Disks,ANRTechnology,8 SATA interfaces for 8 HDDsand capacity of each HDD up to 8TB,minimum02 USB port,AlarmI/O 16/4,RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface,support multi brand network Cameras,ONVIF conformance,Multiple network monitoring: Web viewer .support protocol TCP/IP,DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erectedinprovided URackwith wiringconnections, taggingandprogramming etc. complete as per specificationss no. CCTV-NVR |
| 451 | Supplying, fixing, and configuring 24 ports, PoEswitchcompliant with IEEE 802.3 standards withmin.193WPoEcapacitywith4GESFPuplinkinprovided rack as per specification no. WG-NWC/ENS |
| 452 | Supplying& erecting 8 TB internal Surveillance HDDsuitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/UnloadCycle-3000000, Work Load Ratingper Year180TB, MTBF 1000000 Hrs. HTTPS.RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 453 | Supplying and installing LSZH sheathedHDPE insulatedcopper cat-6 cable suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC |
| 454 | Supplying& erecting 55\"professionalLEDdisplay with 1920 *1080 ( FullHD) Display, suitable for 32/64 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 DutyCycle dulyerected on wall or table top with standard accessorieslike wall mount stand andwiring connections etc. complete as per specifications no. CCTV-MON |
| 455 | Supplying and fixing 9U wall mountrack (Dimension-DxWxH – 500x550x480mm) as per specification no. WG-NAS/RAK |
| 456 | Supplyingand fixing42U floormountserverrack(Dimension-DxWxH–800x1000x2070 mm) as per specification no. WG-NAS/RAK |
| 457 | Supplying and erecting modulartype computer Jack RJ 45 with safety shutter, on provided plate and box with wiring connections complete. (DATA/VOICE/WIFI) |
| 458 | Supplying, erecting & terminating2 pair telephonecopper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW |
| 459 | Supplying, erecting & terminating5 pair telephonecopper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit asper specification no. WG-TW |
| 460 | Supplying, erecting & terminating10 pair telephonecopper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW |
| 461 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min.1.5mm thick MS sheet as per specification no. WG-TA |
| 462 | Supplying, erecting & commissioning10 pairs FR junctionbox with mouldedplastic enclosure as per specification no. WG-TA |
| 463 | Supplying, erecting & commissioning 50 pairs FR junctionbox with mouldedplastic enclosure as per specification no. WG-TA |
| 464 | Supplying, installing, testing & commissioning analoguetype EPABX of 3 x 8extensioncompletewith CLI and voice DISA (Direct inward stationaccess)expandable upto 32 extension as per specification no. WG-TA. |
| 465 | Supplying and erecting LED Strip light Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD0.95, operating range of 230-270V, Life class of 30,000 Hrs at L70B50 including driver with minimum 1 year warranty as per specification No. FG-IDF/LED. |
| 466 | Supplying & errecting of Aluminium Profile of required size with synthetic clear vision cover |
| 467 | Supplying and erecting 1200 MM sweep decorative ceiling Fan |
| 468 | Supplying and erecting occupancy sensor |
| 469 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 470 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, complete |
| 471 | Supplying & erecting HMS PVC conduit 32mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. |
| 472 | Dismantling unserviceable CCTV dome/bullet/PTZ camera fromwall/ceiling/false ceiling/pole (mounting height not more than 5 meter) etc and remaking the site good as original |
| 473 | Supplying, installing and testing earthing with copper earth plate size 30 x 30 x0.315 cm complete with all accessories of copper materials & recording the resultsas per specification no. EA-EP |
| 474 | Supplying,installing,testing& commissioningwindowtypevariablespeed invertertechnologywithminimum3 to 1convertiblemode for compressor, room air conditioning unit 0.7TR to 0.9TR capacity having ISEER minimum 3.1 to maximum3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP- AC/WAC |
| 475 | Supplying,installing,testing& commissioningwindowtypevariablespeed invertertechnologywithminimum3 to 1convertiblemode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum3.1 to maximum3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP- AC/WAC |
| 476 | Supplying, installing, testing & commissioning split type variable speed inverter technologywith minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7TR to 0.9TR capacity having ISEERminimum3.8 to maximum4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of airhandlingunithi-wall/floormountingtypecompletewithrefrigerantR32 having copper condenser, minimum2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC |
| 477 | Supplying, installing, testing & commissioning split type variable speed inverter technologywith minimum 3 to 1 convertible mode for compressor, room air conditioning unit1.0TR to 1.2TR capacity having ISEERminimum3.8 to maximum4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of airhandlingunithi-wall/floormountingtypecompletewithrefrigerantR32 having copper condenser, minimum2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC |
| 478 | Supplying, installing, testing &commissioning cassette type room Air conditioning unit 2.8TR to 3.3TR capacity with refrigerant R32/R410A 415V, 50Hz, A.C. supply having 1 no of air handlingunit(Mega spilt) mountingtype completewith temperature displayonindoorunit,dustfilter,noiselevel maximum 50dBA at position as per specification no. AP-AC/ WAC |
| 479 | Supplying& erectingseamlessoutside&inside,smooth,dry andclean copperpipe with ROHScompliantsuitablefor refrigeranthaving 22SWG thickness and inner dia/size 12mm complete as per specification no. AP/AC-CP |
| 480 | Supplying& erectingseamlessoutside&inside,smooth,dry andclean copperpipe with ROHScompliantsuitablefor refrigerant having 22SWG thickness and inner dia/size 16mm complete as per specification no. AP/AC-CP |
| 481 | Supplying& erectingseamlessoutside&inside,smooth,dry andclean copperpipe with ROHScompliantsuitablefor refrigeranthaving 22SWG thickness and inner dia/size 22mm complete as per specification no. AP/AC-CP |
| 482 | Supplying& erectingseamlessoutside&inside,smooth,dry andclean copperpipe with ROHScompliantsuitablefor refrigeranthaving 22SWG thickness and inner dia/size 32mm complete as per specification no. AP/AC-CP |
| 483 | Supplying& erectingseamlessoutside&inside,smooth,dry andclean copperpipe with ROHScompliantsuitablefor refrigeranthaving 22SWG thickness and inner dia/size 35mm complete as per specification no. AP/AC-CP |
| 484 | Supplying& erectingseamlessoutside&inside,smooth,dry andclean copperpipe with ROHScompliantsuitablefor refrigeranthaving 22SWG thickness and inner dia/size 42mm complete as per specification no. AP/AC-CP |
| 485 | Supplying and erectingelastomericnitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater /AC system. |
| 486 | Supplying and erectingelastomericnitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater /AC system. |
| 487 | Supplying and erectingelastomericnitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater /AC system. |
| 488 | Supplying and erectingelastomericnitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater /AC system. |
| 489 | Supplying and erectingelastomericnitrile rubber / foam tube type sleeves forcoating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42 mm for solar water heater /AC system. |
| 490 | Supplying,erecting, testing andcommissioningof10HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards workingonHFCrefrigerantR410Aorotherrequired/suitable green equivalent refrigerant, for minimumcooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modulartype vertical hot air dischargesuitable for longer pipingrange upto1000m operation incoolingmodewithinverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximumheat transfer area, rain protectioncover, built in oil separator, accumulator and oil receiver,copper tube aluminiumfin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 491 | Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards workingonHFCrefrigerantR410Aorotherrequired/suitable green equivalent refrigerant, for minimumcooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modulartype vertical hot air dischargesuitable for longer piping range upto 1000 metre operationin cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximumheat transfer area, rain protectioncover, built in oil separator, accumulator and oil receiver,copper tube aluminiumfin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 492 | Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioningsystem out door unit (ODU) complies type-IV OEM standards workingonHFCrefrigerantR410Aorotherrequired/suitable green equivalent refrigerant, for minimumcooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modulartype vertical hot air dischargesuitable for longer piping range upto 1000 metre operationin cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximumheat transfer area, rain protectioncover, built in oil separator, accumulator and oil receiver,copper tube aluminiumfin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 493 | Supplying, erecting, testing and commissioning of 24HP, VRF/VRV air conditioningsystem out door unit (ODU) complies type-IV OEM standards workingonHFCrefrigerantR410Aorotherrequired/suitable green equivalent refrigerant, for minimumcooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modulartype vertical hot air dischargesuitable for longer piping range upto 1000 metre operationin cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximumheat transfer area, rain protectioncover, built in oil separator, accumulator and oil receiver,copper tube aluminiumfin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 494 | Supplying, erecting, testing and commissioning of 26HP, VRF/VRV air conditioningsystem out door unit (ODU) complies type-IV OEM standards workingonHFCrefrigerantR410Aorotherrequired/suitable green equivalent refrigerant, for minimumcooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modulartype vertical hot air dischargesuitable for longer piping range upto 1000 metre operationin cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximumheat transfer area, rain protectioncover, built in oil separator, accumulator and oil receiver,copper tube aluminiumfin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 495 | Supply, installation,testingand commissioning of VRF/VRV basedHi-wall type indoor unit (IDU) of nominal cooling capacity 0.6TR - 0.8TR ( 229 to 358 cfm) having EERas per BEEstandardsand specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminalto receivepower supply,etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoorwall mounting, having an electronic control console, provided with suitable mounting brackets withanyadditionalrefrigerantand oilcharge as per the requirementduring installation, connected to the system complete. |
| 496 | Supply, installation,testingand commissioning of VRF/VRV basedHi-wall type room/indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.25TR(417 cfm) having EERas per BEEstandardsand specifications withmultiplespeed evaporator fan withmotor, copper tube aluminiumfin evaporator coil, washableair filter,insulateddraintray, in builtdrainpump, expansiondevice, cordless remote control with necessary controls and electrical terminaltoreceivepower supply,etc. IDUshallhave anti-corrosivecoating suitable for costal area. Unit shall be of decorative slim dimension suitable indoor wall mounting.The indoor unit shall also have an electronic control console. The unitshall be suitablefor wall mountingand providedwith suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installation complete. |
| 497 | Supply, installation,testingand commissioning of VRF/VRV basedHi-wall typeindoorunit(IDU)of nominalcoolingcapacity1.3TR(421 cfm)to 1.7TR (586 cfm) having EERas per BEEstandardsand specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washableair filter, insulateddraintray, expansiondevice, cordlessremote controlwith necessary controls,with3-core copper flexiblecord of required lengthandelectricalterminaltoreceivepower supply,etc. IDUshallhave anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wallmounting, havingan electroniccontrolconsole,providedwithsuitable mountingbrackets withanyadditionalrefrigerantand oilcharge as per the requirement during installation, connected to the system complete. |
| 498 | Supply, installation,testingand commissioning of VRF/VRV basedHi-wall type indoorunit(IDU)of nominalcoolingcapacity1.8TR(594 cfm)to 2.2TR (655 cfm) having EERas per BEEstandardsand specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washableair filter, insulateddraintray, expansiondevice, cordlessremote controlwith necessary controls,with3-core copper flexiblecord of required lengthandelectricalterminaltoreceivepower supply,etc. IDUshallhave anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wallmounting, havingan electroniccontrolconsole,providedwithsuitable mountingbrackets withanyadditionalrefrigerantand oilcharge as per the requirement during installation, connected to the system complete. |
| 499 | Supply,installation,testingand commissioningof VRF/VRV basedceiling suspended 4 Way cassetteindoorunit(IDU)compact/standard sizeof nominal cooling capacity 0.6TR ( 420 cfm )/0.8TR ( 441 cfm ) having EER as per BEEstandardsand specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air portetc. IDUshallhave anticorrosivecoatingsuitablefor costalarea inall respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 500 | Supply,installation,testingand commissioningof VRF/VRVbasedceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominalcoolingcapacity1.5TR(512 cfm) to 1.8TR(618 cfm) having EERas per BEEstandardsand specifications, suitable as per site requirement withswinglouversandadjustablebladesfromsides.IDUwithdrainage arrangements, fan, refrigerantliquidandrefrigerantpiping,cordlessremote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. |
| 501 | Supply, installation, testing and commissioning of VRV / VRF basedductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 2.1TR (800 cfm) to 2.4TR (960 cfm) having EERas per BEEstandards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washableairfilter,insulateddraintray,inbuiltdrainpump, expansiondevice, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosivecoating suitable for costalarea anddecorative slimdimension suitableforceilingsuspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. |
| 502 | Supply, installation, testing and commissioning of VRV / VRF basedductable type, high static room/indoor unit (IDU) having nominal cooling capacity of4.1TR(1640cfm) to5.0TR(2000 cfm)havingEER asperBEE standards andspecificationswithevaporator fanwithmotor,coppertube aluminium fin evaporator coil, washableair filter, insulateddraintray, in built drain pump, expansiondevice, cordless remote controlwith necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitableforcostalareaanddecorativeslimdimension suitableforceiling suspended arrangement with an electronic controlconsoleand anyadditional refrigerant and oil charge as per requirement during installation complete. |
| 503 | Supplyingandinstallationofhighpressure graderequired sizecopper connection Y orT-Joints/refnutcompleteerected onwall/ceilingwith supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. |
| 504 | Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 505 | Supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 506 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 507 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungalgrowth, flamespread, water permeance and ultraviolet radiationwith OEM standards of VRV/VRF air conditioning system complete. |
| 508 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thickelastomericnitrile rubber along with applicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 509 | supplying,laying/fixing,testingandcommissioningof appropriatenominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRFpiping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 510 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 511 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 512 | supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copperpipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipeforrefrigerant)alongwithnecessarysupports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulationof 19mm thickelastomericnitrilerubber alongwithapplicationof multicoatingof VRV/VRF piping for protectionagainst mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiationswith OEM standards of VRV/VRF air conditioning system complete. |
| 513 | Supply, installation, testing and commissioning wireless remote control havingcolourLCDpanel,real timeclock,temperature limitation(16to 30° C,functionslike filter clean remindertimersuitableto communicatewith wired controller complete. |
| 514 | Supplying,erecting,testingandcommissioningcentralised programmable remotecontrol panel (HMI)touchmanagercontrols minimum16 system of 64 ODU\"s canbecontrolledandupto 992 IDU\"s can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel,yearly schedule,power proportionaldistributionfunction, temperature limitation, history function complete erected on wall integrated with provided fire alarm system. |
| 515 | Supplying, erecting, testing and commisioning of 2 core 1 sqmm copper sheathed control cable from indoor to outdoor unit of VRV Unit |
| 516 | SITC of sequential controller for AC\"s units. |
| 517 | Supplying, erecting, testing and commisioning of 20mm conduct pipe for control cableof VRV Unit |
| 518 | Supply, Installation, testing and commissioning of Double Skin Ceiling / Floor Mounted Air Handling Unit with forward / backward curved fan and variable speed drives as per AHU data sheet, VRV/DX coil/CHW coil as specified in AHU Data Sheet, Pre, thermostats, Canvass Connection, Vibration Isolators, supports, merv 8 & merv 13 filter shall be supplied as per the attached AHU data sheet. Filter shall be supplied as per the attached AHU data sheet. All AHU\"s will be with THERMAL BREAK profile. Contractor to consider necessary control & power cabling for PIBCV valve, heater bank etc. The cost of the AHU should include local control panel comparising of necessary starter, VFDs as specified. The Panel to have provision to recieve signal from Fire to trip.T-AHU-05- 8000 CFM/ 23 TR/ ESP 25mm |
| 519 | Supply, installation, testing and commissioning of MS ERW \"C\" class chilled water piping with all necessary fittings i.e. bends, tees, reducers, flanges, structural supports,wooden blocks etc. All pipes shall be of PN-16 pressure rating. A) 250 mm |
| 520 | B) 125 mm |
| 521 | C) 100 mm |
| 522 | D) 80 mm |
| 523 | E) 65 mm |
| 524 | Supply, installation, testing & commissioning ofinsulation for chilled water piping with Nitrile rubber insulation with factory laminated glass cloth as per specs. Sizes as specified in specs. All pipes shall be of PN-16 pressure rating. (For piping on floor not exposed to sunlight) A) 250 mm |
| 525 | B) 125 mm |
| 526 | C) 100 mm |
| 527 | D) 80 mm |
| 528 | E) 65 mm |
| 529 | Supplying and erecting 50 mm dia. cast iron doubleflange butterflyvalve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 530 | Supplying and erecting 65 mm dia. cast iron doubleflange butterflyvalve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 531 | Supplying and erecting 75/80 mm dia. cast iron doubleflange butterfly valve ofsizecompletewithPN16pressurerating,as perspecification no.FF- VL/BFV |
| 532 | Supplying and erecting 100 mm dia. cast iron doubleflange butterfly valve ofsize complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 533 | Supplying and erecting 150 mm dia. cast iron doubleflange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 534 | Supplying and erecting 200 mm dia. cast iron doubleflange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 535 | Supplying and erecting25 mm Ball Valve complete with PN16 pressure rating, as per specification no. FF-VL/BV |
| 536 | Providing and fixing 32/40 mmBall Valve complete with PN16 pressure rating, as per specification no. FF-VL/BV |
| 537 | Providing and fixing 50 mmBallValve with complete with PN16pressure rating, as per specification no. FF-VL/BV |
| 538 | Supplying anderecting 75/80 mmdia Cast Ironend line strainerof Y-type flanged endpattern,PN16pressure rating, SS screen,endconnectionwith Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete as per specification no. FF-VL/ELS |
| 539 | Supplying anderecting100 mmdiaCastIronendlinestrainerof Y-type flanged endpattern,PN16pressure rating, SSscreen, endconnectionwith Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete as per specification no. FF-VL/ELS |
| 540 | Supplying anderecting150 mmdiaCastIronendlinestrainerof Y-type flanged endpattern,PN16pressure rating, SSscreen,endconnectionwith Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete as per specification no. FF-VL/ELS |
| 541 | Supply, installation, testing & commissioning of following sizes Vibration eliminators with double bellows, tie rods and MS flanges as a part of vibration. The vibration eliminators to be insulated type to avoid condensation. A) 250 mm dia |
| 542 | 200 mm dia |
| 543 | Supplying and erecting 100 mm dia. pressure gauge, 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 544 | Steam type Temperature gauge in chilled water line |
| 545 | Supplying anderecting 20/25mmdiagunmetalairreleasecock,with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 546 | Supplying and erecting 25 mm dia., 2.45 mm min. thickness polyethylene composite pipe, conforming to IS 15450 :2004 duly joined by compression/crimp fitted accessories, with internal as well as external end sealing arrangement |
| 547 | Supplying and erecting 32 mm dia., 2.8 mm min. thickness polyethylenecomposite pipe, conforming to IS 15450 :2004 duly joined bycompression/crimp fitted accessories, with internal as well as external end sealingarrangement for Solar Water Heater System as per specification No. ESD HWP/PCP |
| 548 | Supplying and erecting 40 mm dia., 3.4 mm min. thickness polyethylenecomposite pipe, conforming to IS 15450 :2004 duly joined bycompression/crimp fitted accessories, with internal as well as external end sealingarrangement |
| 549 | Supplying and erecting 50 mm dia., 4 mm min. thickness polyethylenecomposite pipe, conforming to IS 15450 :2004 duly joined bycompression/crimp fitted accessories, with internal as well as external end sealingarrangement as for Solar Water Heater System per specification No. ESD HWP/PCP. |
| 550 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 551 | Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 552 | Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 553 | Supplying and erecting GI sheet 1.25 mm (18 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 554 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 555 | Supply, fabrication, installation an testing of flexible canvass connections constructed betweenductableunit/dampers/ducting of suitablesize with fire resist flexible double canvas sleeve complete. |
| 556 | Providing adhesive thermal insulationfor supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2007. |
| 557 | Providing and applying of acousticinsulationfor air ducts with 25mm thick, 48kg/cu.m fiberglassfacedwithRPtissueandcoveredwith26SWG perforated aluminium sheets complete. |
| 558 | Supply, installation, testing and commissioning of manually operated,opposed blade, duct mounted,flanged volume control dampersof requiredsizes in GIconstructionwithoperatingmechanism,mountingarrangement, rubber refrigerant kits etc. complete. |
| 559 | Supply,installation,testingand commissioningof volumecontrolboxwith collar for control damper of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. |
| 560 | Supplying & erecting tile type modulardiffuser made from aluminiumsheet with powder coated matching to the ceiling shade for provided supply and return air complete. |
| 561 | Supplying and installing of collar damperof galvanised iron material of upto 120microns for anti corrosive resistance for supply air grill of suitable size. |
| 562 | Supplying and erecting aluminiumpowder coated linear grill of suitable size for widthlengthwithoutcollardampershaving matchingcolourwiththe existing false ceiling and suitable for deflection of 15/30/45°. |
| 563 | Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline freshairfaninlet unit having 300cfmcapacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete |
| 564 | Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1ph, 230 V, 50Hz, A.C. supply complete. A) VENTILATION FANS - FANS with motor, Starter panels/MCB, with potential free contacts for fire signal trip. |
| 565 | Inline Cabinet type Fans 3000CFM @45 MM Static For Exhaust Air |
| 566 | Inline Cabinet type Fans 2500 CFM @40 MM Static For Fresh Air( with Pre Filter 90% effiency) |
| 567 | S/I/T/C of HVLS fans of 10\" with controller and remote. The HVLS Fan control should include a factory programmed UL Listed, to provide a soft-start for the fan, variable speed control capability, current limit and motor overload protection for the fan & Each control shall be forward/reverse compatible and offer key pad or optional remote operation |
| 568 | Supplying and erecting exhaustfan mediumduty 230 V A.C. 50 cycles 225 mm.1400 RPM with condenser complete erected in positionwith necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 569 | Supplying and erecting exhaustfan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 570 | Supplying & erecting HMS PVC conduit 32mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. |
| 571 | Providing vaccumising the airconditioner system to 200 micron andcharging with R-410A/R32 refrigerant for air conditioning unit. |
| 572 | Duct insulation: Removing of old damaged insulation and cleaning the surface of duct and applying tar on it stick properly fibre glass surface of duct with aluminium foils and seal the joint. |
| 573 | S & E Pipe insulation damaged portion of pipe liner insulation to be cleaned and apply thermocole pipe section on it and plaster with sand cement plaster. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy