| Sl. No. | Item Description |
| 1 | Renovation of First Floor of Admin Building: |
| 2 | Part - A - Civil Works: |
| 3 | Construction of Brick work with common burnt clay F.P.S (Non-Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 (1 Cement : 6 coarse sand) including cost of cement (PPC - Ramco) and all materials etc., complete. |
| 4 | Providing 12 mm thick plaster with CM (1:6) to brick/RR walls at all heights etc., including cost of all materials, tools, plant and labour, scaffolding arrangements and curing all as per specifications and directions of the engineer. |
| 5 | Removal of existing damagedthermocol/ wooden or any kind of false ceiling and handed over to useful material to CE office and dispose the unservicable material to outside HSL premises complete all as directed |
| 6 | Demolishing of RR / Brick wall in Cement mortar by manually / mechanical means including stacking of serviceable material and disposal of unserviceable materials outside HSL premises as per direction of Engineer-in-charge. |
| 7 | Dismantling and removal of wooden / aluminium partitions including hand overing of serviceable material to CE Deptand disposal of unserviceable material as per direction of Engineer-in-charge. |
| 8 | Removal of existing wooden planks (cladding) at walls and floors and handover the same to CE Dept., Complete as directed by Engineer In-charge |
| 9 | Providing Plain Cement Concrete 1:2:4 nominal mix using 20 mmand down graded crushed granite aggregate including mixing, depositing in position, tampering, finishing, curing including all materials & labour etc., complete all as directed. |
| 10 | Supply and providing HSD bar reinforcement of Fe-500 grade of approved make SAIL / RINL / TISCO including transportation, straightning, cutting, bending and binding with annealed binding wire of 18 gauge (1.22mm dia) complete all labour and material etc., complete all as directed |
| 11 | Chipping and removal of old damaged plaster, cleaning the surface thoroughly, applying of Nitobond SBR and plastering with CM (1:4) at beams, parapet wall, lintels, soffits, chajjas, etc including disposal of unserviceable material within 50 metres lead, labour, required scafoldings and materials all complete as per direction of Engineer-in-charge. (NitoBond SBR will be measure and paid seperately) |
| 12 | Supply and providing Nitobond SBR of Fosroc make complete all as directed. |
| 13 | Providing and fixing premium quality Vitrifiedtiles (Double Charged) of size 600X600X 10mm in floors & skirting with water absorption less than 0.08% and conforming to IS : 15622,of approved make KAJARIA in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including removal of existing door shutter, re-size and re-fixing the same, Chipping and removal of existing all types of flooring, disposal of debris outside HSL premises, grouting the joints with white cement andmatching pigments etc., includes the cost of Cement (PPC-Ramco, ACC, Ultratech, Nagarjuna, Birla Gold & Jaypee) & all materials complete all as directed. |
| 14 | Applying two coats of putty of approved brands (Birla / JK ) over one coat of wall primer of(asian/berger) tointernalwallsurfaces up to 3.85 M heightincluding thourough scrapping, cleaning and preparation of existing old surface, Putty surface shall be finished till a smooth and even surface is acheived by using sutiable emeray papers. |
| 15 | Apply two (02) Coats of Premium quality Acrylic Interior Emulsion of required shade to wall surfaces from approved brands Asian Paints (Royale Shine), Berger (Silky Luxury) as specified by Engineer-incharge including necessary scaffolding etc., complete all as directed. |
| 16 | Providing Two (02) coats of synthetic enamel paint over a coat of primer for Doors, Windows & grills etc., of approved brands like Asian / Berger / Nerolac, complete all as directed.(After removing the old paint by using buffing machine and apply 2 coats of wood putty to give smooth surface to frames) |
| 17 | Providing Two(02) coats of white washing with suryaplus or equavalent to ceiling surfaces after through scrapping, sand papering and cleaning the surface to give even shade etc., complete all as directed. |
| 18 | Applying two or more coats of french sprit polish of approved brands including a coat of wood filler on old wooden surface after thourough cleaning and preparation of surface as directed by Engineer-in-charge. |
| 19 | Apply two coats of premium quality weather proofing arcylic Exterior emulsion paint over a one coat of primer, reqired shade to wall surfaces from approved brands Asian paints (apex ultima),Berger (All guard) where ever specified by Engineer after through scrapping & cleaning of old surface including necessary scaffolding etc., complete. (Rate includes scrapping of old surface by mechanically) |
| 20 | Supply and Fix the fabric vertical venetian blinds of approved make Jacobs / Vista including connected extruded aluminium headrails and all accesories etc., complete |
| 21 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for black Granite kitchen platforms of approximate size 2.50x0.60 as per requirement, approved shade, colour and texture including Providing edge moulding and machine polishing to edge to give high gloss finish etc. laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 22 | Provide and fix MS Long tower bolts (powder coated) (barrel type) of size 150x10 mm with necessary fittings for doors. (Item includes removal of old one tower bolt and handed over to CE dept.,) |
| 23 | Provide and fix brass aldrops for doors of 300 mm long 16 mm diawith necessary fittings. (Item includes removal of old damaged aldrop and handed over to CE dept.,) |
| 24 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer of make Godrej or its equivalent (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete |
| 25 | Providing and fixing aluminium hanging floor twin rubber door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete |
| 26 | Providing and fixing aluminium anodised peg stays for windows (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete |
| 27 | Provide and fix ISI marked Stainless steel hinges of size 150 mm long with necessary fittings to doors. |
| 28 | Removal of door / windows with frame and refixing the same in required location including basic repairs all complete as directed by Engineer Incharge |
| 29 | Providing and fixing new 4mm thick float glass by removing the existing damaged glasses in wooden, aluminum window shutters including beading materials, labours etc. as directed by Engineer-in-charge |
| 30 | Dismantling of wooden doors and windows including grills if any and stacking in designated area as directed by Engineer In charge |
| 31 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink of size 610X510 mm bowl depth 200mm as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required etc., complete (Nirali / Anjali / Parryware make) |
| 32 | Repairing of all kinds of false ceiling, replacing of damaged false ceiling boardsincluding all materials, consumables, labours and hiring charges of machinery all complete as directed by Engineer-In-charge. |
| 33 | Removal of existing aluminium partitions and refixing the same to new location after tile flooring including required accessories/ hardware fittings and providing gun painting of required minimum microns all complete as directed by Engineer-In-charge. |
| 34 | Providing and fixing anodized extruded aluminium windows & ventilators (single or double shutter), doors and partitions (single or double shutter) part pannelled and part glazed with pre-laminated flat pressed 12mm thick particle board (NOVAPAN, ECOBOARD etc) of approved colour & make. Aluminium sections shall be powder coated with approved colour including aluminium powder coated frame conforming to IS:1948, IS:1949 fabricated from extruded sections of INDAL / JINDAL or approved equivalent make having minimum 2mm wall thickness for windows & ventilators and 3mm wall thickness for doors & partitions as per IS:1285, IS:733 and electro color coating of 15 microns thickness. Glazing shall be clear float glass of 5.5mm thickness of approved make SaintGobin / Modifloat including sanp fit type beading, concealed screws, fixtures (like tower bolts, hold fast, handles both sides, door stoppers with rubber shoes, \"L\"drops, stays, floor springs, hydralic door closers etc) lokcing arrangement for windows, Godrej make mortice lock with 3 no keys for each door, C.P.brass / staineless steel screws, providing and fixing hinges / pivots, and making provisions for fixing of fittings where ever required including cost of PVC / neoprene gasket fits all complete with necessary fillingup of gaps at the junctions, at top, bottom and sides etc., complete.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired. |
| 35 | Supply of Anti-Termite of Premise Chemical of make Bayer. (Premise contents imidacloprid 30.50% - SC and can be used for Pre and Post Construction anti Termite treatment) complete all as directed. |
| 36 | Spraying the Pest Chemical on wood materials, Doors, windows and other wooden materials etc., by machine drilling of holes around the surface area (Both sides) upto required depth by injecting chemicals into the holes and filling with putty material complete all as directed. (Chemical will be measured seperately) |
| 37 | Providing and fixing of false ceiling with 4mm thick cement bonded particle board of Bison/ V-board or equivalent make boards in 600x600mm grid using aluminium powder coated (50 microns) T-section of size 30x35x1.20mm suspended with 8 swg wire at 1200mm spacing & fixing of false ceiling shall follow IS 2441 & Item includes applying one coat of primer , two coats of putty and two coats of emulsion paint (Asian premium quality) complete all as directed. |
| 38 | Providing and fixing 1st quality anti-skid floor tilesin toilets & wash rooms of 10mm thick (edge cut) of size 300mmx600m (Concept) conforming to IS : 15622,of KAJARIA make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including pointing the joints with white cement and matching pigments etc., Quoted rate shall be including cost ofCement (PPC-Ramco, ACC, Ultratech, Nagarjuna, Birla Gold & Jaypee) & all materials complete all as directed. (Rate includes chipping of existing all types of Floor tiles/ wall tiles, disposal of debris outside HSL premises) |
| 39 | Providing and fixing 1st quality 10 mm thick (edge cut) Ceramic Glazed wall tiles in dados conforming to IS : 15622,ofapproved make SOMANI / KAJARIA, (Concept model) in all colours and shades, laid on 12mm thick cement pigment of MYK Laticrete / Saint Gobian or its equivalent to maintain the levels at joints including pointing in white cement mixed with pigment of matching shade. (Rate includes chipping of existing wall tiles, disposal of debris outside HSL premises & prepartion of surface with one layer of CM plaster of 1:5) |
| 40 | Supply and fixing of 25 mm thickPVC doors with frame & shutter for toilets (Sintex / Hi-Techor equvilant make) including aluminium aldrop, towerbolt, handles and butt hinges etc., complete |
| 41 | Providing and fixing white vitreous china flat back lipped front Urinal basin of 430x260x350 mm of Parryware of Hindware make with G.I clamps, 32mm dia PVC waste pipe, 15mm dia PVC polythene connector including fittings and brackets, cutting and making good the walls and floors wherever required etc., complete (Parryware/ Hindiware) |
| 42 | Providing and fixing white vitreous china urinal partition of required size with G.I clamps including fittings and brackets, cutting and making good the walls and floors wherever required etc., complete (parryware/ hindiware) |
| 43 | Supplying, fitting andglazed vitreous china wash basin 550X400mm Size of Parryware / Hindware / Jaquar make with central tap hole including supplying and fixing of C.I brackets painted with one coat of approved red oxide Zinc Chromate primer and two coats of approved synthetic enamel paints, 15mm dia Chromium plated approved deluxe head pillar tap of Hindware/Parry make, 32mm dia Chrome Plate waste couplings, flexible waste hose, chain rubber plug etc,all as per drawings, specifications and directions of the Engineer, including all materials, tools, plant and labour etc., complete |
| 44 | Supply, fit and fix white glazed earthenware European type water closest of Parryware / Hindware / Jaquar make with \"P\" or \"S\" trap with or without vent hole, colour or black solid plastic seat and cover with low level cistern of 10 litres capacity of same make as specified including all fittings, materials, tools and labour etc., complete. |
| 45 | Providing and fixing 6 mm thick frame less beveled edge mirror of superior glass of approved quality of Saint gobian / modi gaurd complete using stain less steel studs including all accessories etc., complete |
| 46 | Providing CP health faucet including 1.5m flexible pipe of make Watertec or its equivalent including all accessories etc., complete |
| 47 | Supply and providing UPVC Nano - trap of make sudhakar or supreme with ss grating complete all as directed. |
| 48 | Providing and fixing CP soap Dish Holder of approved makehaving length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms etc., complete |
| 49 | Providing and fixing 600mm wide CP Towel rail of standard length of approved make including all accessories etc., complete |
| 50 | Providing 2 peg, brass CP coat hooks of standard quality etc., complete |
| 51 | Supply & Fixing Brass CP bib cocks (long body) of make Waterteck or its equivalent Complete all as directed. |
| 52 | Supply & Fixing 15 mm dia bore Brass C.P angle cocks/stop cocks of waterteck or its equivalent standrd quality with 15mm dia bore and Complete all as directed. |
| 53 | Supply of 110 mm dia UPVC (SWR) Soil and waste pipes conforming to IS : 13592 Type B, jointing with seal ring conforming to IS : 5382, including fixing of clamps, bends, shoes (supreme/ prince make) complete |
| 54 | Supply of 75 mm dia UPVC (SWR) Soil and waste pipes conforming to IS : 13592 Type B, jointing with seal ring conforming to IS : 5382, including fixing of clamps, bends, shoes (supreme/ prince make) complete |
| 55 | Providing and fixing 15 mm nominal dia Pipes CPVC pipes for plumbing lines of approved make Supreme / Prince / Astrial including fittings and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 56 | Providing and fixing 20 mm nominal dia Pipes CPVC pipes for plumbing lines of approved make Supreme / Prince / Astrial including fittings and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 57 | Providing and fixing 25 mm nominal dia Pipes CPVC pipes for plumbing lines of approved make Supreme / Prince / Astrial including fittings and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge |
| 58 | Supply, fittingand fixing 25 mm nominal dia in position galvanised steel (Heavy duty) distribution pipes (of make Jindal / Zenith) of the followingsizes conforming to IS: 1239 at all heights and depths above and below plinth level including necessary galvanised steel fittings such as bends, elbows, tees, plugs, sockets, short pieces, clamps etc., and testing of the pipe lines hydraulically, all as per drawings, specifications and directions of the engineer, complete all materials, tools, and labour all as directed |
| 59 | Detach the existing Work Stations without damaging and re-fixing the same after completion of renovation work, complete all as directed. (Item includes the necessary screw fittings etc., shall be arranged by the Contractor) |
| 60 | Provision of AC hole by cutting of existing RR masonry wall by Core cutting machine wihtout damaging the existing wall complete all as directed. |
| 61 | Providing and Laying water proofing treatment consisting of (i) Removal of existing damaged membrane and through cleaning of existing RCC roof slab and dispose the same to outside the yard. (ii) Providing and laying cement plaster in CM 1:6 (where ever required to cover the undulation of slab surface) duly admixed with sika plastocrete super @0.2% by weight of cement, over a bond coat of sika latex cement slurry to make the surface smooth and even.(iii) Application of priming coat compatible bituminous pimer Sika WP shied primer W @0 300 Kg as per sqm over the cleaned and prepered roof surface complete as per satisfacton of the engeer in - charge. and filling of cracks with Cebex 100 by providing pressure grounting.(iv) Providing and laying STP (Shalimar) or Sika atactic polypropylene polymer (APP) modified five layer prefabricated waterproofing membrane withthermal fusible properties on both side and having minimum thickness of 3.0mm and unit weight not less than 4.0kg /sqm reinforced with non woven spun bonded troch and sealing all joints properly ,leaving no bare edge or end ofAPP membrane and finishing the surface with trowel of other wise to obtain a unifrom surface the minimum size side lap and end lap shall be kept at 75mm and 100 mm respectively the membrane shall be laid over a coat of bituminous primer @0.300kg /lit per sqm made by the same membrane manufactualy after necessry surface prepartory work such as cleaning the surface thoroughly ,shaping mounths of out lets including cutting grooves (50mmx50mm) in parapet and inserting edge of membrane and mending good damages by sand cement mortar (1:4)and shall be finished in all respect as per directon of engineer -in -charge.(v) Applying two coats of aluminium painting. |
| 62 | Part - B - Electrical Works: |
| 63 | Supply, fix, test and commissioning of 3 phase, VTPN 12 way double door MCBDB with 100 Amps, 4 pole MCCB as main incomer and 10 A to 32 A, 10KA SP/DP MCBs as outgoings including all accessories as required and as directed. Approved make Schneider/ Siemens/ ABB / Havells or Equivalent. |
| 64 | Concealed PVC conduit wiring with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for One point controlled by one switch as directed (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 65 | Concealed PVC conduit wiring with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for Two point controlled by one switch as directed (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 66 | Concealed PVC conduit wiring with 3 runs of 2.5 sq.mm FRLSH PVC flexible copper cable for switch sockets as directed (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 67 | Concealed PVC conduit wiring with 3 runs of 4 sq.mm FRLSH PVC flexible copper cable for AC units, Oven and Refrigerators (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 68 | Supply, fix, test & commissioning of 3 modular type switch board with 01no. 16A (3+2 pin) modular socket and switch. |
| 69 | Supply, fix, test & commissioning of 3 modular type switch board with 01no. 6A (3+2 pin) modular socket and switch. |
| 70 | Supply, fix, test & commissioning of 8 modular type switch board with 01no. 16A (3+2 pin) modular socket with switch & 02nos. 5A 3-pin modular socket with switch as directed by engineer in-charge. |
| 71 | Supply, fix, test & commissioning of 8 modular type switch board with 03nos. 3pin 5A modular socket with 2nos. switches as directed by engineer in-charge. |
| 72 | Supply, fix, test & commissioning of 8 modular type switch board with 5A 3-pin modular sockets & switches as directed by engineer in-charge. |
| 73 | Supply, fix, test & commissioning of 16 modular type switch board with 5A 3-pin modular sockets & switches as directed by engineer in-charge. |
| 74 | Supply, fix, test & commissioning of 4 modular type switch board with 04 nos. 5A modular switches as directed by engineer in-charge. |
| 75 | Supply, fix, test & Commissioning of 20A DP MCB DB & 16A Socket with enclosure for AC units as directed by engineer in-charge. |
| 76 | Supply, fix, test and commissioning of 2X2, 36 / 39Watt ceiling mounted White LED fixture with all accessories (Approved make Wipro/ Jaquar/ philips/ CG/ Havells or Equivalent) |
| 77 | Supply, fix, test & commissioning of 20W LED Tube light as directed by engineer-incharge. |
| 78 | Supply, fix, test and commissioning of 18W, ceiling mounted White LED fixture with all accessories (Approved make Wipro/ Jaquar/ philips/ CG/ Havells or Equivalent) |
| 79 | Supply, fix, test & commissioning of Mirror light as directed by engineer-incharge. |
| 80 | Supply, fix, test & commissioning of Hand Dryer as directed by engineer-incharge. |
| 81 | Supply, fix, test & commissioning of 7W LED bulb with holder as directed by engineer-incharge. |
| 82 | Supply, fix, test & commissioning of 1phase, 240V, 1200 mm 5 star rated Ceiling Fan as directed by engineer in-charge. |
| 83 | Supply, fix, test & commissioning of 1phase, 240V, 400 mm sweep wall mounted fan as directed by engineer in-charge. |
| 84 | Supply, fix, test & commissioning of 1phase, 240V, 400 mm sweep Pedestal fan as directed by engineer in-charge. |
| 85 | Supply, fix, test & commissioning of 1phase, 240V, 300 mm sweep exhaust fan with louvers as directed by engineer in-charge. |
| 86 | Wireless Calling Bell as approved by Engineer in-charge |
| 87 | Removal of all existing wiring material, Switch Boards, fittings, cables, electrical panels, equipment etc. and handover to Plant Maintenance Dept. |
| 88 | Supply, fix, test & commissioning of 18W LED recess mounted ceiling light as directed by engineer in-charge. |
| 89 | Supply, install, test and commissioning of 5 Star rated, inverter type, 2.0T Split AC unit (Cu. Condenser) with Stabilizer, Power cable, 3Mtr. Cu Pipe, Stand for Outdoor unit, remote etc. Recommended makes: Bluestar, Voltas, Carrier, OG |
| 90 | Part - C - LAN Works: |
| 91 | UTP CAT 6 Cable |
| 92 | PVC 1\" Conduit Pipe |
| 93 | Casing & capping |
| 94 | I/O Box Full Set |
| 95 | CAT 6 UTP Patch Chords(1 meter) |
| 96 | Unloaded Jackpanel(24-Port) |
| 97 | CAT 6 Information outlets (Key Stones for unloaded Jack panel) |
| 98 | Unloaded Switch 24 G / 4 SFP |
| 99 | Unloaded Switch 48 G / 4 SFP |
| 100 | MM Transcivers for supplied switches |
| 101 | Laying UTP/STP cable and PVC Conduit Pipe |
| 102 | Fixing I/O box set |
| 103 | Laying of OFC |
| 104 | Splicing charges per core |
| 105 | Fixing of Switch |
| 106 | Fixing of Jackpanel |
| 107 | Fixing of LIU |
| 108 | Renovation of OPS room to Convert to Video Conference Room cum Auxiliary Conference Hall: |
| 109 | Civil Works: |
| 110 | Removal of Existing damaged Wooden Wall Cladding and handed over to CE office. |
| 111 | Supply and application of two coats of approved brand Putty including scraping of old paint with mechanically (Buffing machine), preparation of wall surface andcomplete job as directed by Engineer-in-Charge. |
| 112 | Apply two coats of premium quality arcylic interior emulsion paint over a one coat of primer, required shade to wall surfaces from approved brands (Asian Paints -Royal shine, Berger- silky luxury) whereever specified by Engineer-in-Charge including necessary etc., complete. |
| 113 | Removal of existing False Ceiling and Supply and fixing of Bison board / V-board type false ceiling with Aluminium powder coated channels of approved brands including fixing of strips, angles, making of grids etc., to complete job and as directed by Engineer-in-Charge. (Item Includes Removal of existing false ceiling without any damage and same is handed over to CE dept.,) |
| 114 | Providing & fixing premium quality Vertified tiles (Double Charged) of size 600x600x10mm in floors with water absorbtion less that 0.08% and conforming to IS 15622, of approved make SOMANI/ KAJARIA in all colours and shades laid on 20mm thick cement pigment of MYK Laticrete/ Saint gobian or its equivalent material to maintain the level including grouting the joints with white cement and matching pigments etc., and all materials complete all as directed. |
| 115 | Supply and Fixing of Venetian blinds including removal of old venetian blinds and fixing of new venetian blind (Zebra Roller Blinds) as directed by Engineer-in Charge. |
| 116 | Providing 12mm thick Cement Plastering with CM (1:5) to walls at all heights and ceiling, beams, staircase, lintel, soffits, chajjas, projections, narrow bends and widths etc., including cost of all material, tools, plant and labour, scaffoldings and curing all as per specifications and directions of the engineer. |
| 117 | Refubishment of existing door shutter including carryout the repair work by fixing of teak venering to match the existing veneer sheet etc., and providing 2 coats of teak polish complete all as directed. (Item includes removal of door shutters, re-size and re-fixing the same to the existing frame) |
| 118 | Supply and fixing of Hydraulic Door Closer of Godrej make complete all as directed. |
| 119 | Provide & fix Matt Finish SS Color Half Round Heavy Duty Tower Bolt for Doors - Aluminium Body and SS Rod of size 150x10 mm with necessary fittings etc., complete all as directed. |
| 120 | Provide and fix Brass aldrops for doors of size 300mm long 16mm dia with necessary fittings etc., complete all as directed. |
| 121 | Providing and fixing chromium plated brass 100mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc., complete all as directed. |
| 122 | Supply and fix 5\" (Inch) Premium Stainless Steel Door Butt Hinges (Slow Movement Hinges) with necessary fittings etc., complete all as directed. |
| 123 | Supply and fix 6\" (Inch) Premium Stainless Steel Door Handles with necessary fittings etc., complete all as directed. |
| 124 | Construction of Brick work for closing the window with CM (1:6) complete all as driected. (Item includes by removal of existing aluminium window safely and handed over to CE dept.,) |
| 125 | Electrical Works: |
| 126 | Supply, fix, test & commissioning of 3 modular type switch board with 01no. 6A (3+2 pin) modular socket and switch for wall mount fans |
| 127 | Supply, fix, test & commissioning of 3 modular type switch board with 01no. 16A (3+2 pin) modular socket and switch for wall mount fans |
| 128 | Supply, fix, test & commissioning of 8 modular type switch board with 03nos. 3pin 5A modular socket with 2nos. switches as directed by engineer in-charge.(On conference table and on walls) |
| 129 | Supply, fix, test & commissioning of 12 modular type switch board with 5A 3-pin modular socket & switches for lightsas directed by engineer in-charge. |
| 130 | Concealed PVC conduit wiring/Casing capping with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for one point controlled by one switch as directed |
| 131 | Concealed PVC conduit wiring/casing capping with 3 runs of 2.5 sq.mm FRLSH PVC flexible copper cable for switch sockets as directed |
| 132 | Concealed PVC conduit wiring/casing capping with 3 runs of 4.0 sq.mm FRLSH PVC flexible copper cable for switch sockets as directed |
| 133 | Supply and fix and test and commissioning of 20AMP DP MCB with DB for AC units as directed by the EIC |
| 134 | Supply, fix, test and commissioning of 2X2, 36 / 39Watt ceiling mounted White LED fixture with all accessories (Approved make Wipro/ Jaquar/ philips/ CG/ Havells ) |
| 135 | Supply, fix, test & commissioning of 1phase, 240V, 400 mm sweep wall mounted fan as directed by engineer in-charge.(Crompton, Orient, Havells |
| 136 | Supply, install, test and commissioning ofinverter type, 2.0T cassette AC unit (Cu. Condenser) with Stabilizer, Power cable, 3Mtr. Cu Pipe, Stand for Outdoor unit, remote etc. Recommended makes: Bluestar, Voltas, Carrier, OG |
| 137 | Supply and laying of Addl. Copper pipe with foam |
| 138 | 100mm dia. Core cutting of 2ft thick RR Masonary Wall for Split AC Units as directed by Engineer in-charge |
| 139 | Supply and laying of 1 inch PVC Conduit for AC drain |
| 140 | Removal of all existingSwitch Boards, light fittings, A.C\"s equipment etc. and handover to Plant Maintenance Dept. |
| 141 | Shifting of VC Facility: |
| 142 | 24 Ports LIU Unloaded |
| 143 | MM pigtails with adapters |
| 144 | 6U Rack with all accessories |
| 145 | OFC 6 Core MM cable |
| 146 | UTP Cat 6 Cable |
| 147 | I/O Box full set |
| 148 | Unloaded Jack panel (24-Port) |
| 149 | Cat 6 information outlets(Key stones) for unloaded jack panel |
| 150 | HDPE 32mm Pipe |
| 151 | laying of OFC cable |
| 152 | Laying of HDPE |
| 153 | Fixing of Rack |
| 154 | Fixing of Switch |
| 155 | Splicing Charges |
| 156 | Shifting of LED Display with Polycam device |
| 157 | Laying of UTP Cable |
| 158 | Fixing of LIU |