| 1 | Main Entry Gate & Guard Room |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 coarse sand (zone-III) : 10 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 5 | All works upto plinth level |
| 6 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 7 | (i) R.C.C. work in Footing |
| 8 | (ii) R.C.C. work in Beam |
| 9 | (iii) R.C.C. work in Columns |
| 10 | All works above plinth level upto floor V level |
| 11 | (i) R.C.C. work in Beam |
| 12 | (ii) R.C.C. work in Columns |
| 13 | (iii) R.C.C. work in Slab |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 16 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 17 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 19 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) |
| 20 | 12 mm cement plaster on the fair side of single or half brick wall (a) 1:6 (1 cement: 6 coarse sand) |
| 21 | 6 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand) |
| 22 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). |
| 23 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 24 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 25 | Providing and fixing machine cut, mirror/ eggshell polished , granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charg .Granite of all colour except black, cherry/ruby red 18 mm thick (slab area above 0.50 sqm) |
| 26 | Steel Painting:Applying priming coat: |
| 27 | (a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 28 | (b) Painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:Two or more coats on new work. |
| 29 | Same as above but wooden painting |
| 30 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 31 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 34 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. |
| 35 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 36 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer |
| 37 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size |
| 38 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 39 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer |
| 40 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size |
| 41 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 42 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. |
| 43 | 300 x 10mm |
| 44 | 200 x 10mm |
| 45 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete(a) 125 mm. |
| 46 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper |
| 47 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. |
| 48 | (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. |
| 49 | (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. |
| 50 | (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 51 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 52 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 53 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 54 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 55 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 56 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 57 | Electrical Works |
| 58 | Point wiring in PVC conduit, with modular type switch :- |
| 59 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 60 | Group A |
| 61 | Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- |
| 62 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 63 | Circuit / Sub main wiring in PVC conduit :- |
| 64 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. |
| 65 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 66 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 67 | 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 68 | Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. |
| 69 | S/F modular type blanking plate :- |
| 70 | Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 71 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 72 | 8 way , Double door |
| 73 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C\" series,miniature circuit breaker (MCB)suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. |
| 74 | single pole |
| 75 | Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. |
| 76 | Supply of 20W SURFACE MOUNTED LED TUBE with all accessories as per standard item.. |
| 77 | Supplying and fixing following rating, Single/ double/ three pole, 230/ 415 volts, MCB \"C\" curve in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 78 | 40 amps DP MCB |
| 79 | Supplying and fixing following rating, Single/ double/ three pole, 230/ 415 volts, MCB \"C\" curve in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 80 | 40 amps DP MCB |
| 81 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 82 | ERECTIONOFLIGHTINGFIXTURES |
| 83 | Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |