}

Tender For Trans Catheter Aortic Valve Implant Set, Micropuncture Set And Aortic Stent Graft., Perambur-Tamil Nadu

Southern Railway-SR has published Tender For Trans Catheter Aortic Valve Implant Set, Micropuncture Set And Aortic Stent Graft.. Submission Date for this Tender is 11-03-2024. Springs Tenders in Perambur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42334415
Tender For Trans Catheter Aortic Valve Implant Set, Micropuncture Set And Aortic Stent Graft.
Open Tender
Indian
Tamil Nadu
Perambur
11-03-2024

Tender Details

Supply Of Trans Catheter Aortic Valve Implant Set, Micropuncture Set And Aortic Stent Graft., ( Sr Ph Code 152101 ) Self Expandable Transcatheter Aortic Valve Implant Set Consists Of The Following In Sterile Individual Pack, ( I ) .Transcatheter Heart Valve - 01 Unit. It Should Be Made Of Bovine / Porcine Pericardium Tri Leaflet Valve , Made Of Medical Grade Alloy. The Size Of The Valve Should Range From 20 Mm To 35 Mm Or More. ( Ii ) .Valve Delivery System-01 Unit ( Iii ) .Balloon Dilatation Catheter-02 Unit Balloon Size Ranges From 16 Mm To 35 Mm With 30 Mm Length For Pre And Post Dilation. ( Iv ) .Introducer Sheath 01 Unit Compatible With All Valve Sizes. Should Have Haemostatic Valve Should Be Compatible For Femoral Artery Size Ranging From 5 Mm To 7 Mm. ( V ) Inflation Device - 02 Units ( 30Ml / 40Ml / 60Ml ) ( Vi ) Syringes 50Cc- 02 Units ( Vii ) Extra Support Double Curve 0.035Inch Wire-240Cm For Valve Delivery ( Viii ) Suture Mediated Vascular Closure Device- 2 Units. ( Ix ) Temporary Pacing Lead-01 Unit For Burst Pacing. The Firm Should Be Able To Supply Any Size Of Valve, Delivery System And Balloon Suitable For The Patient. Unit: No. , ( Sr Ph Code 152053 ) Micropuncture Set Consisting Of 5Fr Inroducer 21G Introducer Needle And Nitinol 0.018 Inch Guide Wire ( Unit -Number ) , ( Sr Ph Code 152054 ) Micropuncture Set Consisting Of 4Fr Inroducer 21G Introducer Needle And Nitinol 0.018 Inch Guide Wire ( Unit- Number ) , ( Sr Ph Code 153060 ) Aortic Stent Graft :- Should Enable Endovascular Treatment Of Arch Of Aorta And Descending Thoracic Aorta Aneurysms And Dissections. The Stent Graft Should Come In Various Lengths And Diameters. It Should Consist Of ( 1 ) A Self Expanding, Tubular Endoprosthesis Composed Of A Polyester Graft Fabric And A Spring Scaffold Made From Nitinol Wire. ( 2 ) Radiopaque Markers Are To Be Sewn To The Fabric To Radiographically Visualize The Edge Of The Graft Material To Provide A Guide To The Minimum Overlap Distance Required. ( 3 ) A Pre- Loaded Delivery System. ( 4 ) Aortic Occlusion Balloon To Assess The Aneurysm / Dissection With Angiography ( 5 ) Marker Pigtail To Assess In Proper Sizing And Deployment. ( Unit- Number ) , ( Sr Ph Code 153061 ) Aortic Stent Graft :- Should Enable Endovascular Treatment Of Aortic Aneurysms And Dissections. The Stent Graft Should Come In Various Lengths And Diameters, Which Should Be Two Component An Aortoiliac Bifurcated And A Contralateral Limb. It Should Consist Of ( 1 ) A Self Expanding, Stent Graft Composed Of Fabric And Scaffold Made From Nitinol Wire. ( 2 ) Radiopaque Markers Are To Be Sewn To The Fabric. ( 3 ) Should Able To Add Additional Configurations Include Iliac And Aortic Extensions . ( 4 ) Aortic Occlusion Balloon To Assess The Aneurysm / Dissection With Angiography ( 5 ) Marker Pigtail To Assess In Proper Sizing And Deployment. ( Unit-Number )

Key Value

Document Fees
Refer document
EMD
INR 53970.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail