Tender For Repair/Maintenance Of Ac Sheet/Cgi Sheet, False Ceiling And Certain E/M Repair Work At Otm Accommodation Under Ge (North) Binnaguri, binnaguri-West Bengal

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Ac Sheet/Cgi Sheet, False Ceiling And Certain E/M Repair Work At Otm Accommodation Under Ge (North) Binnaguri. Submission Date for this Tender is 09-03-2024. False Celing Tenders in binnaguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42323518
Corrigendum : Tender For Repair/Maintenance Of Ac Sheet/Cgi Sheet, False Ceiling And Certain E/M Repair Work At Otm Accommodation Under Ge (North) Binnaguri
Open Tender
Indian
West Bengal
binnaguri
09-03-2024

Tender Details

Repair/Maintenance Of Ac Sheet/Cgi Sheet, False Ceiling And Certain E/M Repair Work At Otm Accommodation Under Ge (North) Binnaguri

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Feb-2024 Amendment BOQ 09-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work :REPAIR/MAINTENANCE OF AC SHEET/CGI SHEET, FALSE CEILING AND CERTAIN E/M REPAIR WORK AT OTM ACCOMMODATION UNDER GE (NORTH) BINNAGURI
Sl. No. Item Description
1Dismantling of Plain or corrugated AC sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
2Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed.
3Supply and fix rolled mild steel tubular work in hollow tubular / square / rectangle section as in roof trusses, ( framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc. conforming to relevant IS complete all as specified and as directed.
4Supply and fix prepainted galvalume aluminium zinc coating GI based corrugatedsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
5Supply and fix prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in as in ridges, valley, eaves, etc with self tapping screws complete all as specified and as directed.
6S&F 20 mm the 2nd class hardwood boarding both side plained and edges tounged and grooved or rebated and fixed with nails in any situation as in eaves board complete all as specified and as directed.
7Material and labour for false ceiling with GI powder coated frame work and 4 mm thick E board classic design, non asbestos fibre reinforced cement board, reinforced Designer Board tiles conforming to IS-14862 and ISO-8336, of approved texture at all height duly suspended ceiling laid on hot dip galvanised iron imposed grid of size 600 mm x 600 mm, T section / Angle section including cutting holes in brick wall and making good surface with cement concrete 1:2:4 type B-0 / 1:3 cement mortar complete all as specified and having following details: (a) 27mm x 27 mm angle 0.55 mm thickness, GI powder coated hot dip galvanised plugged at the rate 600mm centre to centre alongwith the perimeter of wall. (b) 25 mm x 25 mm Tee0.55 mm thickness, GI powder coated hot dip galvanised as main and cross runner suspended with 1.6 mm dia GI wire suspenders (not exc. 1.20 mtr length) with adjustable clamps and dash true fastners plugged in RCC slab or angle iron runner of slopped roof placed at the rate 600 mm centre to centre alongwith the perimeter of wall. Note: The work shall be carried out as per manufacturer"s instruction and as directed.
8S&F in repair of POP seamless false ceiling with powder coated GI snap grid frame workcomplete all as specified and directed including all necessary drilling and necessary arrangement to fix items as under:- (a) Perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mmfixed to surrounding wall using nylon sleeves and screws450 mm c/c intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit including ceiling section of 0.55 mm thick having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to intermediate channel 1.6mm dia GI wire suspenders (n.exe 1.2 mtr length) with adjustable clamps and dash true fastners plugging in RCC slab/wooden truss/A.I Runner of slopped roof placed @ 600mm centre to centre from perimeter of wall. (b)Fixing of calcium silicate ceiling made out of 1800x1200 mm x8mm thickfixed to ceiling section with 25mm long self drilling and tapping screws complete.
9S&F in repair solid PVC wall lining consisting of 5mm thick single side prelam wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame including 5mm thick PVC sheet fillet of width 35mm as per specifications and drawing complete all as specified and as directed.
10S&F in repair for 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorativechoice lamination & other side balancing white lamination, fixed with screwsto timber frame work as in cupboard door/shelves/wall paneling including 6 mm thick wooden leaping and dismantling of old boarding complete all as specified and as directed. Note : The cost is including polishing to wood surfaces.
11Taking down cement plaster on wall of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
12M&L for rendering 15mm thick in CM (1:6) on concrete/brick wall surfaces finished even and fair without using extra cement complete all as specified and as directed.
13M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @2% by the weight of cement or as per manufacturer"s instructions finishing the surface even and fair without using extra cement complete all as specified and as directed. Note : Integral water proofing compound shall be measured and paid separately.
14Supply only liquid water proofing compound conforming to relevant IS specification complete all as specified and as directed
15Demolition of brick work built in cement mortar and removing from site complete all as specified and as directed.
16M&L brickwork with fly ash bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 by using old size bricks complete all as specified and as directed.
17M&L for applying two coats of exterior emulsion paint(weather coat) over a coat of exterior primer damp coat on a new plastered surfaces of facia, roof projection, chajja etc including necessary preparation of surfaces complete all as specified and as directed.
18M&L for preparation of new or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of primer over a coat of wall care putty over plastered surface to prepare the surface even and smooth complete all as specified and as directed.
19M&L for preparing old decorated plastered or unplastered surfaces of walls including cornices, pilasters and other wall features etc by brooming down or steel wire brushing scrapping down to remove smoke soot moulds moss and efflorescence salts and treating oil and greasy spots etc and applying one coat of white washing on the same complete all as specified and as directed.
20M&L for preparing oil bound distemper surfaces of walls including cornices, pilasters and other wall features etyc by washing rubbing down and stopping and applying one coat of Oil bound distemper on the same complete all as specified and as directed.
21M&L for preparation of new wooden surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
22M&L for preparation of new or previously untreated steel surfaces any description over 10 Cm in width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed.
23M&L for preparation of old painting to wooden and wooden based surfaces of any description not otherwise described, over 10 Cm width or girth and applying one coat of synthetic enamel paint on the same complete all as specified and as directed.
24M&L for preparation of old painting to steel surfaces of any description not otherwise described, over 10 Cm width or girth and applying one coat of synthetic enamel paint on the same complete all as specified and as directed.
25Demolition of RCC as in slab beam lintels, shelves chajjas or facia, reinforcement cut as required to facilitate demolition and making the surface even and fair with cement mortar 1:4 and painting work to match as per existing etc complete all as specified and as directed.
26INTERNAL ELECTRIFICATION Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit includingremovalof batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and separating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
27Taking down carefully existing old/unserviceable sub main wiring of any size/description as existing at the sit including making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
28M&L for concealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with allaccessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylam sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB"s or common earth dolly for one light point controlled by one, one way switch complete all as specified and as directed.
29All as per item Ser No 28 here in before butfor one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
30All as per item Ser No 28 here in before but for one 3/5 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
31All as per item Ser No 28 here in before butfor one 3/5 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
32All as per item Ser No 28 here in before but for one bell point controlled by one, bell switch 5 Amps complete all as specified and as directed.
33All as per item Ser No 28 here in before but for one light point controlled by one, two way switch 5 Amps complete all as specified and as directed.
34All as per item Ser No 28 here in before butusing 2.5 Sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
35S&F of switch piano flush type 5/6 amps single pole one way complete all as specified and as directed.
36S&F of switch piano flush type 16 Amps single pole two way complete all as specified and as directed.
37S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
38S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
39S&F of switch piano flush type 15/16 amps single pole one way complete all as specified and as directed.
40S&F of switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable complete all as specified and as directed.
41S&F in repair switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable complete all as specified and as directed.
42S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
43S&F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
44S&F in replacement LED white glass lamp 1x9/10 Watt 230 Volts with B 22 base complete all as specified and as directed.
45S&F deluxe fan electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
46S&F in repair switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
47S&F in repair modular switch 6 Amps one module complete all as specified and as directed.
48S&F in repair modular switch 16 Amps one module complete all as specified and as directed.
49S&F in repair modular socket 6 Amps 2/3 pin combined 2 module 230 volt flush type complete all as specified and as directed.
50S&F in repair modular socket 6/16 Amps2/3 Pin combined 2 module 230 Volts flush type complete all as specified and as directed.
51S&F in repair modular fan regulator 120W 230 Volts AC 50 Hz 2 modules complete all as specified and as directed.
52S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
53M&L for Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 Security light fitting luminaire with high power LEDs as light source and driver of capacity 25 watts withpre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor cable from ceiling rose to fitting and GI Pipe bracket made out of GI pipe medium grade 1.2 Mtr long 32 mm dia , MS clamp, nut, bolt and washers including necessary taking down complete all as specified and as directed.
54S&F of Bulk head luminaire suitable for 10 WattLED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
55S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser,integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed.
56S&F Recess mounting flat panel 34 Watt LED fitting (2"X2") for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection including necessary taking down complete all as specified and as directed.
57S&F Post top lanterns 20 watt LED light fitting ,new generation, energy saving, environmental friendly, long life with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories internally prewired including connecting up with three core twisted flexible copper conductor cable up to ceiling rose and necessary mounting arrangements and taking down of old unserviceable one complete all as specified and as directed.
58Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductorof size 4 Sqmm standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspend ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old cable complete all as specified and as directed.
59Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductorof size 6 Sqmm standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspend ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old cable complete all as specified and as directed.
60M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts gradewith stranded copper conductor includingone run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic conduit including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed. Note: Two runs of sub main wiring cable alongwith one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
61All as per item No 60 above but using two runs 4.0 Sqmm multistranded copper conductor single core cable with one run 4.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed.
62Supply and fix moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 25 to 100 Amps of breaking capacity 16 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
63Supply and fixed in repairs MCB TPN 40 to 100 Amps,"C" series 10kA, 415 Volts and to be housed in DBscomplete including necessary connection complete all as specified and as directed.
64S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/isolators complete with and including taking down old unserviceableone all as specified and directed including taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
65S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/isolators complete with and including taking down old unserviceableone all as specified and directed including taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
66S&F in repair MCB, Single pole & neutral, 32 amps, 240 volts, ‘C’ curve, 10KA allcomplete with and including taking down old unserviceableone complete all as specified and as directed.
67S&F MCB, Single pole, 6 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unserviceableone complete all as specified and as directed.
68S&F in replacement epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240 Volts, C Series current carrying capacity 10 kA, including necessary connection completeall as specified and as directed.
69Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, check nuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on complete and dismantling old existing one all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail