Uttarakhand Power Corporation Limited-UPCL has published Replacement Of Dog Conductor To Aaa C Conductor In 33 Kv Sarwakher Line Under Edd Jaspur. Submission Date for this Tender is 01-03-2024. Conductor Tenders in jaspur Uttarakhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 29-Feb-2024 | Time Extand | Date | 01-03-2024 |
Sl. No. | Item Description |
1 | Supply Item |
2 | Supply of Bracing Clamp made of M S Flat for ST Pole SP-55 with Nut and Bolts and washer. (As Per Specification & Drawing of UPCL) |
3 | Supply of Bracing Clamp Bottom of M S Flat for ST Pole SP-55 with Nut and Bolts and washer. (As Per Specification & Drawing of UPCL) |
4 | Supply of Nut and Bolts as per Norms. |
5 | Supply of X-arm (Guard Angle) for ST Pole SP-55 made of M.S. Flate with nut and bolts and washer without cracks & burrs. (As Per Specification & Drawing of UPCL) |
6 | Supply of Earth wire Clamp of M S Flat for ST Pole SP-55 with Nut and Bolts and washer. (As Per Specification & Drawing of UPCL) |
7 | Supply of Stay Clamp of M S Flat for ST Pole SP-55 with Nut and Bolts and washer. (As Per Specification & Drawing of UPCL) |
8 | Supply of PG Clamp Aluminioun alloy for Panther to Panther Conductor. (As Per Specification & Drawing of UPCL) |
9 | Supply of 33 KV F Clamp of M S Flat for ST Pole SP-55 with Nut and Bolts and washer. (As Per Specification & Drawing of UPCL) |
10 | Supply of Stay Insulator. (As Per Specification & Drawing of UPCL) |
11 | Supply of Danger Board complete by providing clamps M.S. Flate 50x6 mm with danger board of M.S. Sheet 2 mm Thick 11"7" Size.(As Per Specification & Drawing of UPCL) |
12 | Supply of 33 KV Jointing Kit. (As Per Specification & Drawing of UPCL) |
13 | Supply of 33 KV Tension Clamp with Bail & IPC. (As Per Specification & Drawing of UPCL) |
14 | Supply of 33 KV Cable Ties for Pin Insulator. (As Per Specification & Drawing of UPCL) |
15 | Supply of 33 KV IPC for Covered to Covered Conductor. (As Per Specification & Drawing of UPCL) |
16 | Supply of 33 KV IPC for Covered to Bare Conductor. (As Per Specification & Drawing of UPCL) |
17 | Supply of IPC with Aluminium bail for Earthing. (As Per Specification & Drawing of UPCL) |
18 | Supply of 33 KV AAAC Covered Conductor Al-59, 241 Sq.mm. (As Per Specification & Drawing of UPCL) |
19 | Supply of barbed wire as per Norms. |
20 | 33 KV AAAC Conductor Work |
21 | Cartage of the following material by private truck from store centre Rudrapur /Haldwani/ Kashipur to work site dump store approx. distance 0 to 20 Km. including loading into truck and unloading at work site. Dump store and carriage from dump store to pit site. |
22 | ST Pole SP-55 |
23 | Small Line Material including Cable/Conductor |
24 | Head Load Cartage of following material road to work site approx. distance 0 to 1 Km. including loading and unloading. |
25 | ST Pole SP-55 |
26 | Small Line Material including Cable/Conductor |
27 | Fabrication of Channel/angle to Single/Double/Tri/Four pole Structure Straight Cross arm T off Top and Dropper, Brecing Channel of M.S. Channel 125x65 & M S Angle 65x65x6 mm Cutting and Holling in all respect as per Specification of UPCL. |
28 | Excavation of earth for Stay set pit of size 0.6x0.6x1.2 Mtr Length in all type of soil including proper dressing of sides and ramming of bottom including getting out soil and disposal of surplus excavation soil as directed complete work in all respect. |
29 | Erection of 33 KV Stay Set complete in all respect as per specification of UPCL. |
30 | Grouting of Stay in size (0.6x0.6x0.3)in CC ratio 1:4:8 (1Cement :4Graded Stone :20 mm nomial size :8 coarse sand) Block Including cost of material complete in all respect as per specification of UPCL. |
31 | Excavation of Earth for Pole Pit of Size (.9x.6x1/6) of pole length in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and diposal of surplus soil as directed complete work. |
32 | Erection of following Single/Double Support of pole in proper level and alignment along with fixing of all accessories, complete in all respact as per Specification of UPCL. |
33 | Single Support of ST Pole SP-55 |
34 | Double Support of ST Pole SP-55 |
35 | Grouting of Pole in size (.45x.45x1/9) length of support in CC ratio 1:4:8 (1Cement:4Graded Stone:20mm nomial size:8 coarse sand) Block Including cost of material in all respect. |
36 | Muffing of Pole in size (.45cmx.6cm) radious with CC ratio 1:3:6(1Cement :3core sand:6 graded stone 10mm nomial size) Block size 45cm height from ground level Including cost of material in all respect. |
37 | Painting of STP Pole SP-55 with two coats of Aluminum paint Berger Luxol quality over one coat of red oxide primer and P.O. red on top above guarding angle in all respect as per Specification of UPCL. |
38 | Fabrication and Installation of Guarding (on avg of 45 Mtrs Span) for protection of road/telephone lines/HT/LT lines as per RESPO Drawing No RES-48 with guarding channel size 100x50 mm and GI wire 8/6 SWG cross wire including fixing with all accessories complete in all respect as per Specification of UPCL. |
39 | Making of Section Pole complete in all respect as per Specfication of UPCL. |
40 | Febraction of Steel complete in all respect. |
41 | Fixing and Installation of Danger Board/Number Plate complete in all respect as per Specification of UPCL. |
42 | Cartage of Petty Material 21-50 KM. |
43 | Laying and stringing of HT line Fixing with all accessories proper sag including binding etc. in all respect as per Specification of UPCL. |
44 | Back Cartage of Petty material approx. distance 0 to 20 Km. including loading and unloading. |
45 | Fixing of 33 KV Tension Clamp with IPC Complete in all respect as per Specification of UPCL. |
46 | Fixing of 33 KV IPC for CC to CC Conductor Complete in all respect as per Specification of UPCL. |
47 | Fixing of 33 KV IPC for CC to Bare Conductor Complete in all respect as per Specification of UPCL. |
48 | Fixing of 33 KV Mid Span Jointing kit Complete in all respect as per Specification of UPCL. |
49 | Fixing of IPC with Al Bail for Earthing Complete in all respect as per Specification of UPCL. |
50 | Replacement of old damaged/broken/Tilted X-arm. |
51 | Back Head Load Cartage of Petty Material 0-1 KM. |
52 | Fixing of 33 KV Cable Ties Complete in all respect as per Specification of UPCL. |
53 | Renozzeling of Existing Stay Set. |
54 | Digging of Pit and Straight of Tilt Pole. |
55 | Laying and stringing of 33 KV AAAC Covered Conductor AL-59 241 Sq mm Complete in all respect as per Specification of UPCL. |
56 | Dismantiling of old Existing 33 KV Conductor HT Line complete in all respect. |
57 | Looping and Chopping of Tree Branches. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy