| 1 | Item No.1:- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Additional Spec. No.Bd.A.1 Page One Number 259 (SSR 22-23 It.No.21.02 ) |
| 2 | Item No.2:-Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Additional Spec. No.Bd.A.2 Page One Number 259 (SSR 22-23 It.No.21.06 ) |
| 3 | Item No.3:-Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means Additional Spec. No. Bd.A.3 Page One Number 259 (SSR 22-23 It.No.21.10 ) |
| 4 | Item No.4:-Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) Additional Spec. No.Bd. E. 1 Page One Number 287 (SSR 22-23 It.No.24.01) |
| 5 | Item No.5:-Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Additional Spec. No. Bd.F.3 Page One Number 298 and B.7, Page One Number38 (SSR 22-23 It.No.25.11 ) |
| 6 | Item No.6:-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Additional Spec. No. Bd.F.5 Page One Number 300 and B.7, Page.One Number 38 (SSR 22-23 It.No.25.31) |
| 7 | Item No.7:-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Additional Spec. No.Bd.F.6 Page One Number 300 and B.7, Page One Number38 (SSR 22-23 It.No.25.50 ) |
| 8 | Item No.8:- Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Additional Spec No. Bd.F.9 Page One Number 303 and B.7, Page One Number38 (SSR 22-23 It.No.26.05) |
| 9 | Item No.9:-Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Additional Spec. No.Bd.G. 1 Page One Number 313 (SSR 22-23 It.No.27.01 ) |
| 10 | Item No.10:- Filling in plinth and floors with approved excavated material in 15cm. to 20cm.Layers including watering and compacting etc. complete. Additional Spec. No. Bd.A.10 PageOne Number 262 (SSR 22-23 It.No.21.36 ) |
| 11 | Item No.11:-Filling in plinth and floors with contractors material/brought from outside and approved by Engineer inchargein layers of 15 cm to 20 cmincludingwatering andcompaction etc. complete. Additional Spec. No.Bd.A.11 Page One Number 263 (SSR 22-23 It.No.21.37 ) |
| 12 | Item No.12:-Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Additional Spec. No.As directed by Engineer in charge. (SSR 22-23 It.No.21.40) |
| 13 | Item No.13:-Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Additional Spec. No. Bd.F.8 Page One Number 302 and B.7, Page One Number38 (SSR 22-23 It.No.25.70 ) |
| 14 | Item No.14:- Providing and laying Cast insitu/ReadyMixcementconcreteinM20of trap/ granite/quartzite/gneiss metal for steps including steel centering,formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Additional Spec. NO. Bd.E.2 Page One Number 288 and B.7 Page No 38 (SSR 22-23 It.No.24.06 ) |
| 15 | Item No.15:- Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Additional Spec. No. Bd.F.17, Page One Number 306 (SSR 22-23 It.No.26.33 ) |
| 16 | Item No.16:-Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Additional Spec. No. Bd.G.5 Page One Number 315 (SSR 22-23 It.No.27.05 ) |
| 17 | Item No.17:- Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. Additional Spec No. Bd.G.7 Page One Number 316 (SSR 22-23 It.No.27.06 ) |
| 18 | Item No.18:-Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Additional Spec. No. Bd. L.2 Page One Number 368 (SSR 22-23 It.No.32.03) |
| 19 | Item No.19:-Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Additional Spec. No.Bd.L.4 Page One Number 368 (SSR 22-23 It.No.32.06) |
| 20 | Item No.20:-Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Additional Spec. No. Bd.L.7 Page One Number 369 (SSR 22-23 It.No.32.11 ) |
| 21 | Item No.21:-Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Additional Spec. No. As directed by Engineer in charge. (SSR 22-23 It.No.32.21 ) |
| 22 | Item No.22:-Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc.complete. Additional Spec. No. As directed by Engineer in Charge: (SSR 22-23 It.No.32.26 ) |
| 23 | Item No.23:-Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Additional Spec. No. As directed by Engineer in charge. (SSR 22-23 It.No.32.34 ) |
| 24 | Item No.24:-Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Additional Spec. No.As directed by Engineer-In- Charge (SSR 22-23 It.No.33.68 ) |
| 25 | Item No.25:-Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight1.070 Kilogram/ One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/ Running metre.As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box Additional Spec. No.As directed by Engineer in charge. (SSR 22-23 It.No.39.42) |
| 26 | Item No.26:- Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Additional Spec. No. As directed by Engineer in charge. (SSR 22-23 It.No.39.68 ) |
| 27 | Item No.27:-Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Additional Spec. No.Bd.U.1 Page One Number 537 (SSR 22-23 It.No.40.01) |
| 28 | Item No.28:- Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. Additional Spec. No. BD-T-36 Page One Number 500 (SSR 22-23 It.No.39.10 ) |
| 29 | Item No.29:-Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete Additional Spec. No. As directed by Engineer in charge. (SSR 22-23 It.No.39.58 ) |
| 30 | Item No.30:-Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). Additional Spec. No. BD-T-57 Page One Number 511 (SSR 22-23 It.No.39.26 ) |
| 31 | Item No.31:-Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Additional Spec. No. Bd.M.12 Page One Number 385 (SSR 22-23 It.No.33.42 ) |
| 32 | Item No.32:-Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.Additional Spec. No.Bd.M.12 Page One Number 385 (SSR 22-23 It.No.33.43 ) |
| 33 | Item No.33:-Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters Additional Spec. No. As directed by engineer-in- charge. (SSR 22-23 It.No.42.53 ) |
| 34 | Item No.34:-Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Additional Spec. No.BD.V 5 page 551 and as directed by Engineer in charge (SSR 22-23 It.No.42.55 ) |
| 35 | Item No.35:- Providing and fixing on walls/ceiling/ floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Additional Spec No.BD.V 5 page 551 and as directed by Engineer in charge (SSR 22-23 It.No.42.56) |
| 36 | Item No.36:-Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Additional Spec No.Bd.V.9 Page One Number 555 (SSR 22-23 It.No.41.43 ) |
| 37 | Item No.37:-Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Additional Spec. No.Bd. M-12 page One Number 385 (SSR 22-23 It.No.33.67) |
| 38 | Item No.38:-Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Additional Spec. No.Bd.M.13 Page One Number 386. (SSR 22-23 It.No.33.26) |
| 39 | Item No.39:-Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. Additional Spec. No.As directed by Engineer in charge. (SSR 22-23 It.No.42.30) |
| 40 | Item No.40:-Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe andwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Additional Spec. No.As directed byEngineer in charge. (SSR 22-23 It.No.42.52) |
| 41 | Item No.41:-Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram with frame etc complete. Additional Spec. No.Bd.V.43, Page One Number 574 (SSR 22-23 It.No.42.12) |
| 42 | Item No.42:-Providing and fixing 10 cm PVC nahani trap with grating etc. complete. Additional Spec. No.BD.V 32 A page 551 and as directed by Engineer in charge (SSR 22-23 It.No.42.67) |
| 43 | Item No.43:-Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Additional Spec.No.As directed by Engineer in charge. (SSR 22-23 It.No.38.34) |
| 44 | Item No.44:-Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Additional Spec. No. Bd.C.2 Page One Number 275 (SSR 22-23 It.No.23.01) |
| 45 | Item No.45:-Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. Additional Spec. No.As directed by Engineer- in- charge. (SSR 22-23 It.No. 35.14 ) |
| 46 | Item No.46:-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Additional Spec. No.Bd.P.5 Page One Number 413 (SSR 22-23 It.No.36.11) |
| 47 | Item No.47:-Fixing in position Road Junction/ Informatory Sign Board in ground with C.C.1:4:8 block of 60cm x 60cm x 75cm size including all leads complete. Additional Spec. No.MORTH 801 (SSR 22-23 It.No.6.20) |
| 48 | Item No.48: Charges for testing of material in vigilance and quality control laborator for concrete compressive strength of C.C. Cube (Set of 3 cubes) Rate as per SSR 22-23 |
| 49 | Item No.49: Charges for testing of material in vigilance and quality control laboratory for Metal (Sieve Aalysis) Rate as per SSR 22-23 |
| 50 | Item No.50: Charges for testing of material in vigilance and quality control laboratory for BRICKS Water Absorption (Set of 5 Bricks), compressive strength (Set of 5 Bricks), Efflorescence (Set of 5 Bricks) Rate as per SSR 22-23 |
| 51 | Item No.51: Charges for testing of material in vigilance and quality control laboratory for Steel Bar testing upto 16mm. (set of3 bars) Rate as per SSR 22-23 Sr.No.72 P.No.6 |
| 52 | Item No.52: Royalty charges b) For all other Minerals except Natural Sand=Royalty+ surcharge (2%)= 211.95 + 4.23 - 216.18 per cum. As per SSR 22-23 Section V P.No.3 |