Tender For Refurbishment Of Residential Quarters For Category - C And Sa Type Houses In North Pdpm Phase - 25 In Dae Township, Kalpakkam., kalpakkam-Tamil Nadu

Department Of Atomic Energy-DAE has published Tender For Refurbishment Of Residential Quarters For Category - C And Sa Type Houses In North Pdpm Phase - 25 In Dae Township, Kalpakkam.. Submission Date for this Tender is 09-03-2024. Building Work Tenders in kalpakkam Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42237193
Corrigendum : Tender For Refurbishment Of Residential Quarters For Category - C And Sa Type Houses In North Pdpm Phase - 25 In Dae Township, Kalpakkam.
Open Tender
Indian
Tamil Nadu
kalpakkam
09-03-2024

Tender Details

Refurbishment Of Residential Quarters For Category - C And Sa Type Houses In North Pdpm Phase - 25 In Dae Township, Kalpakkam. Refurbishment Of Category - C And Sa Type Houses.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-03-2024

Key Value

Document Fees
Refer document
EMD
INR 427600.0 /-
Tender Value
INR 2.13 Crore /-

BOQ Items

Name of Work:
Sl. No. Item Description
1CIVIL ITEMS: Excavating trenches of required width by mechanical means (Hydraulic excavator / manual means) for pipes, cables etc., for depth upto 1.5m in all kinds of soil including excavation for sockets, dressing of sides, ramming of bottoms, getting out the excavated soil and then refilling the soil as required in layers not exceeding 200mm in depth, consolidating each deposited layer by ramming, watering etc., and disposing of surplus excavated soil as directed within a lead of 50m, (Disposed soil to be leveled by breaking clods, if any and neatly dressed), etc., all complete as per specification.
2Providing and laying in position of plain cement concrete using hard granite broken stone for all insitu leveling courses in foundations, floor, roof screeding, encasing pipes, etc., including mechanical mixing, ramming, compaction, leveling, curing, dewatering, if any including the cost of formwork etc., all complete as per specifications.
31 : 5 : 10 (1 cement : 5sand : 10 graded stone aggregate 40mm nominal size)
41 : 3 : 6 (1 cement : 3sand : 6 graded stone aggregate 20mm nominal size)
5Filling in depression with cement brick aggregate concrete 1:2:4 using 20mm size broken brick aggregate including compacting, curing etc., all complete upto Floor V level
6Supplying, placing in position and removing Formwork for all insitu concrete works including sloped roof and arches etc., as per drawings and specifications, all centering, scaffolding complete (Note: Measurement for the formwork shall be the area of forms in contact with concrete surfaces).
7Providing and fixing double scaffolding system (cup lock type) on the exterior side at all height made with 40mm diameter M.S. tube spaced @ 1.5m center to center at both horizontal and vertical tubes, joining with cup and lock system with M.S.tube, M.S.tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners connection with the building, etc., Wherever required for the inspection of work at required location with essential safety features for the workmen, etc., complete as per directions and approval of Engineer-in-charge. (Note: The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.)
8Providing and casting insitu Reinforced Cement Concrete 1:1.5:3 using machine crushed hard broken granite stone of nominal size 20mm including mechanical mixing, transporting, placing at all lifts, vibrating, consolidation, curing, finishing smooth all exposed faces, for all insitu concrete items, etc. as per drawings and specifications. Note : The rate quoted shall be exclusive of reinforcement and formwork which will be paid for separately under relevant items.
9Providing, cutting, bending, placing and binding Steel reinforcement using TMT bars of Fe-500 grade in all reinforced cement concrete works including cutting, bending,fixing, tieing in position with 1.6 mm dia soft drawn annealed binding wire, cost of cover blocks in C.M 1:2, etc., complete as per specifications and drawings. ImportantNote: The required quantity of steel reinforcement as mentioned in the schedule should be procured by the contractor only of SAIL, Rashtriya Ispat Nigam Limited (VIZAG), TATA Steel & JINDAL from authorized dealers which shall conform to IS: 1786 (Latest Edition).
10Providing, hoisting and fixing in position of 50mm thickness of precast slabs in cement concrete 1:1.5:3 using hard broken stones of maximum size 20mm finished smooth of various sizes and patterns including necessary formwork and moulds, mechanical mixing, finishing the exposed surface, curing, fixing at all levels, grouting with CM / Cement grout wherever required, etc., all complete excluding cost of reinforcement which will be measured separately under relevant item as per specifications and as direction of the Engineer-in-charge.
11Providing and laying brick masonry in Cement Mortar 1:6 at all lifts withwell burnt chamber bricks / FALG Bricks including scaffolding, curing, raking out joints and including dismantling the existing brick work, disposing the dismantled debris within 2 kms lead etc., all complete as per specifications and as directed by the Engineer-in-charge.
12Providing and constructing 110mm thick (plus or minus 5mm) brick work in Cement Mortar 1:4 usingwell burnt chamber bricks / FALG Bricks including scaffolding, curing, raking out joints etc., and including dismantling the existing brickwork, disposing the dismantled debris within 2 Kms lead etc., all complete as per specifications and as directed by Engineer-in-charge.
13Providing and constructingCompound wall in brickwork usingwell burnt chamber bricks / FALG Bricks of approved quality in CM 1:4, consisting of 110mm thick brick work, 230 x 230mm size brick pillars at every 3 meters intervals and at junctions, corners, etc., brick on edge layer at bottom and top as coping including dismantling the existing brick work, disposing the dismantled debris with in 2 Kms lead, curing, racking out joints, etc., all complete as per specifications and as directed by the Engineer-in-charge.
14Providing and laying Indian Patent Stone Flooring with cement concrete 1:2:4; 20mm thick using 10mm and below size hard broken stones including dismantling the damaged portion of existing floor/dadoo, preparation of surface, consolidating,curing, rubbing the surfaces smooth, providing dividing strips, disposing the dismantled debris at suitable places as shown at site within 2Km lead, etc., all complete as per specification and as directed by the Engineer-in-charge.
15Providing and laying In-situ mosaic flooring and dadooing using best Indian white and colour marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume, 6mm thickness laid over a bed of 12mm (Average) thick bed mortar in CM 1:3 including chipping the damaged portion of existing floor/dadoo, preparation of surface with bed mortar, laying/compacting the mixed mosaic chips thoroughly with grinding stone, curing, polishing the with suitable grit corborundum stone at specified interval, disposing the dismantled debris at suitable places shown at site within 2Km lead, etc., all complete as per specification and as directed by Engineer-in-charge.
16Providing and fixing Kota stone work of 20-25mm thick polished, (premoulded and prepolished slab) machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations or required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups, etc., including dismantling the existing IPS/Mosaic platform/ dadoo, disposal of debris, rubbing, curing, finishing, providing holes of required diameter, providing opening to fix counter basins, providing grooves wherever required, polishing the surface etc., all complete at all levels as per specifications as directed by Engineer-in-charge. [Note: The Kota stones shall be got approved by the Engineer before making bulk order.]
17For Kitchen platforms using Single piece of length upto 1.20 mtr.
18Providing and fixing beading at the ends of platform to arrest water fall by cutting the Kota stone slab of size 25 to 40mm wide, rounding the edges, polishing and fixing to the platform with necessary metal paste including finishing the surfaces etc., all complete as per specification and as directed by Engineer-in-charge.
19Repolishing the Mosaic flooring and skirting with medium and fine polishing using 120 to 150 and 320 to 400 grit corborundam stones with the use of floor polishing machine/Hand polishing including washing thoroughly with soap powder and wax polishing, etc., as per specification and as directed by the Engineer-in-charge.
20Repairing and rectifying the minor repair workslike wall cracks, floor cracks, spalling of mortar on sides of doors, windows, wall and door joints, including the cost of materials, T&P using CM 1:3 etc., all complete as directed by the Engineer-in-charge.
21Providing water proofing treatment at sunken portion of toilet, utility, bathroom etc,. with two coat of two component highly flexible polymer modified cementitious water proofing coating of make FAB chemical (Mixguard AC) or Bostik (Boscolastic) or equivalent including preparation of surface free from dust/oil/grease, sealing the UPVC sleeve pipes using non shrink grout mortar over bonding coat using SBR chemicals and sealing the joints with polyester fleece along the periphery of UPVC pipes, appling two coat of water proofing etc,. all complete as detailed below as per manufacturer specification and as directed by Engineer-in-charge. Surface preparation: The surface to receive water proof treatment shall be cleaned to make sure that the surface free from dust, dirt, laitance, debris, loose mortars, oil particles etc., which may negatively affect the adhesion of water proof treatment with mother concrete surface. Sealing bore hole gap around the sleeve pipes: The gap around the pipe shall be filled with non shrink grout mortar of make FAB chemicals (Mixgrout NS) or equivalent and providing necessary slurry tight form work to enveloping the pipe with a bead of 6 to 8mm and 5mm above the surface level along with a sealer coat of make FAB chemical (Mixprime AC100) or equivalent and seal with saturated polyester fleece all along the periphery of pipes. Water proof treatment: Providing and applying two coats of two component Highly elastomeric flexible polymer modified cementitious cold applied water proof coating of make FAB chemical (Mixguard AC) or Bostik (Boscolastic)over the prepared surface to cover complete area, finishing etc. Extend the coating up to a minimum of 300mm height to the adjoining wall as per manufacturer specification.
22(Note:- 1) All the sunken portion shall be tested for the water leaking before and after treatment by filling with water for 24hours and grouting shall be carried out if any leakage found. 2) The treatment should be done by an agency specialized in the job having sufficient knowledge of waterproofing treatment. 3) Five years guarantee from the date of completion of maintenance period shall be given by the contractor in the prescribed format of the department for the workmanship and the materials provided.)
23Providing and inserting 12mm (± 2mm) dia Galvanized steel/ Aluminium injection nipple suitable to withstand high pressure grouting in honey comb area/weak/porous concrete including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing, making the hole dust free by blowing compressed air, sealing the sides of injection nipple with adhesive chemical of make MC Bauchemie (MC Fix-ST) or Bostik (Plug leak) or other approved make and allow it to cure, etc., all complete as directed by Engineer-In-Charge.
24Providing and injecting PU based injection grout of make MC Bauchemie (MC Inkjet 2700L) or other approved make in proportion as recommended by the manufacturer into cracks/honey-comb area of concrete by suitable two component injection gun/pump at required pressure including mixing of two component,injecting at specified pressure, cutting of nipples after curing, etc., all complete as directed by Engineer-In-Charge. Note:- i) The payment shall be made on the basis of actual weight of approved grout injected. ii) Mixing ratio of chemicals, consumption and application shall be as per manufacturer specifications. ii) Mixing ratio of chemicals, consumption and application shall be as per manufacturer specifications. iii)The treatment should be done by an agency specialized in the job having sufficient knowledge of grouting in concrete. iv)Cost of providing and fixing of injection nipples will be paid for separately under relevant item.
25Arresting the leakages in the floor and wall joints in bathroom/toilet/ all rooms by chipping the joints upto 20 to 30mm deep and grouting with cement mixed with approved water proofing compound @ 2% (two percent) by weight of cement including finishing the surface, disposing the debris at suitable places, etc., all complete as per specification and as directed by the Engineer-in-charge.
26Providing and laying 1st quality Rectified (Jointless) Ceramic floor tiles (Glazed or Anti-skid) of size 300x300 mm or more confirming to IS : 15622of KAJARIA (Approved concept of Digital Series) or SOMANY (Digital Series - Glasstra) or JOHNSON (Approved concept of Satin & Rustic / Glossy series) or approved equivalent make in all colours, shades in Floors laid over 20 mm thick cement mortar 1 : 4 (1 Cement : 4 sand), jointing with grey cement slurry @ 3.3 kg per sqm including dismantling the existing insitu mosaic or terrazzo tile flooring, preparation of surface, grouting the joints with white cement and matching pigments, curing, disposing the dismantled debris at suitable places shown at site within 2Kms lead,etc., all complete as per specification.
27Providing and fixing 1st quality Rectified (Jointless) Glazed ceramicwall tiles of size 300x450 mm or more of approved concept series confirming to IS 15622 of "KAJARIA (Digital Series) or JOHNSON (Satin &Rustic / Glossy series)] or SOMANY or other approved make in all colours and shades in Skirting, Risers of steps and Dados laid over 12 mm thick bed of cement mortar 1 : 3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm or by using Cement based high polymer modified quick set tile adhesive (water based) or other approved tile adhesive including providing Motiff tiles as per approved concept, pointing in white cement mixed with pigment of matching shade, chipping the existing insitu mosaic / plastering or cuddappah stone dadoo, preparation of surface, disposing the dismantled debris at suitable places shown at site within 2Km lead, etc., all complete as per specifications and as directed by Engineer-in-Charge.
28Supplying and fixing of Rigid PVC nosing of approved quality and colour at the corners of Ceramic tiles dadooing including finishing all complete as directed and as per specifications.
29Providing Half Round Edge Moulding to 16-18mm thick marble / Granite or 20-25mm thick Kota stone counters, vanities, sills, etc. including machine polishing theedges to give high gloss finish etc., all complete as per specifications and as directed by Engineer - in – charge.
30Kota stone work
31Removing unconditioned existing MS gate (Single leaf) from the Brick pillars without damaging the gate and refixing the same by making pocket holes near the hold fast portion and packing with CC 1:2:4 mix and finishing to theexisting surfaces etc., all complete and as directed by the Engineer-in-charge.
32Providing and laying in position of Mortar Bund of size 50x40mm (upto 1.00 metre length) in Cement Mortar 1:3 (1 Cement: 3 sand) at sill level of doors including dismantling the existing bund, disposing the debris, making exposed surfaces smooth with cement slurry, curing, etc., all complete as per specifications and as directed by Engineer -in-charge.
33Providing and laying in position of Mortar Bund of size 50x50mmin Cement Mortar 1:6 (1 Cement: 6 sand) at terrace level of checking for water seepage/leaks in the ceiling of housesincluding dismantling the mortar bund for afetr seven days of stagnating water and disposing the debris, makingsurfaces smoothetc., all complete as per specifications and as directed by Engineer -in-charge.
34Supplying and fixing 20mm to 25mm thick both side polished cuddapah stone slabs for Shelves in Cupboard/Wardrobe/Shoe rack, tumbler slabs etc., including removing the existing wooden tiers, fixing by cutting a chase of appropriate width with cutter and embedding the stone into the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) finished smooth, front face polishing, rounding the edges, etc., all complete as per specifications and as directed by Engineer-in-charge. (Note: Cudappah stones shall be got approved by the Engineer before making bulk order)
35Supplying and fixing 20mm to 25mm thick both side polished Kota stone slabs for kitchen shelves, tumbler slabs etc., including cutting a chase of appropriate width with cutter and embedding the stone into the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) finished smooth, front face polishing, rounding the edges, etc., all complete as per specifications and as directed by Engineer-in-charge. (Note: Kota stones shall be got approved by the Engineer before making bulk order)
36Providing and fixing 14-16mm thick table rubbed White Agaria Marble Stone slab of following size and fixed in shelves, above wash basin, bath, etc., includingcutting a chase of appropriate width with chase cutter, embedding (min 50mm) the stone into the chase with epoxy grout or with cement concrete 1:2:4 or white cement, finished smooth, rounding the exposed edges, polishing, etc., all complete as per specification and as directed by Engineer-in-charge. (Note: Size of the slabs indicated are the exposed area of shelves i.e., excluding embedded area.)
37600x125mm size for wash basin
38250x250mm Corner round for bathroom
39Repairs to the wall and ceiling cracks by chipping and removing the damaged portion upto 20 to 30mm deep, 100 to 200mm wide and plastering with CM 1:3 including making grooves over cracks, grouting with cement slurry or approved crack filling compound, providing Glass fibre mesh, applying necessary approved quality bonding chemicals, finishing the surface, curing, white washing two coats, disposing the debris within 2Kms lead etc., all complete as per specification and as directed by the Engineer-in-charge.
40Repairs over the spalling on concrete members by chipping and removing the damaged portion and plastering with CM 1:3 including cleaning the surfaces, applying rust converter of approved quality, filling the damaged portion with cement concrete wherever required, applying necessary approved quality bonding chemicals, finishing the surface in layers, curing, white washing two coats, disposing the debris within 2Kms lead etc., all complete as per specification and as directed by the Engineer-in-charge.
41Providing and fixing best quality Stainless Steel sink without Drain board of overall size 610 x 510mm (Bowl depth 200mm) of make "NIRALI / PRAYAG" or other approved equivalent make of 1mm thick Stainless Steel grade AISI-304 (18/8) as per IS-14283, including fixing over opening in RCC slab of platform or supplying and fixing CI bracket pair andplacing the sink over the platform/bracket to correct line and level, basket type choke stop stainer, waste coupling with check nuts, providing flexible hose from waste coupling to Nahani trap or Waste line, finishing the platform surface with white cement or other approved grouting materials etc., all complete as per IS-14283 specifications and as directed by Engineer-in-charge.
42Plastering with Cement Mortar 1:5, 12mm thick for brickwork / Concrete on its internal faces at all lifts including scaffolding, curing and forming grooves wherever necessary all complete as per specifications and as directed by the Engineer-in­charge.
43Plastering with Cement Mortar 1:5, 12mm thick for brickwork / Concrete on its external faces at all lifts including scaffolding, curing and forming grooves wherever necessary all complete as per specifications and as directed by the Engineer-in­charge. [Note: 6mm premium glass fibre of make Dugar & Co or Recron shall be mixed with Cement @ 60 gms of glass fibre per 50kgs of cement]
44Providing Rough cast plaster 19 mm thick consisting of 7 mm thick rough cast in C.M 1.3 using 6 mm and below size granite chips over 12 mm thick base coat of cement mortar 1:5 for the external faces including providing necessary grooves in plaster as per drawings scaffolding curing etc., complete all as per specification.
45Plastering with Cement Mortar 1:5; 20mm thick for brickwork / concrete, finished smooth including scaffolding, curing and forming grooves wherever necessary and including chipping the plastering, applying bonding agents, disposing the dismantled debris, etc all complete as per specifications and as directed by Engineer.
46Providing and laying Pressed clay Tiles of 230x230mm of approved make colour and pattern over roof at all elevations jointed with cement mortar 1:4 (1 Cement : 4 Coarse sand) mixed with 2% of integral water proofing laid over a bed of 20mm thick cement motar 1:4 (1 Cement : 4 Coarse sand) and finished neat complete.
47Repairs over weathering course leakages by chipping out damaged portion, cleaning thoroughly washing the surfaces making V grooves on cracks, grouting with cement slurry sealing the cracks with replastering/concreting finishing etc. all complete as directed by the Engineer-in-charge.
48Providing Flush pointing on roof tiles by removing the damaged pointing over existing roof tiles, cleaning, removing any growth of vegetation, washing thoroughly, pointing the joints with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement including filling the gap with polymer modified mortars or other approved water proofing chemicals etc., all completed as per specification and as directed by Engineer-in-charge.
49White/Colour washing One Coat of lime solution using shell lime of approved quality admixed with glue, ultra marine etc., on existing surfaces of walls and ceiling at all lifts including cost of all materials, labour, scaffolding, removing nails, brooming down the surfaces for removing cobwebs, smoke dirt etc., filling the holes, cracks, crevices with Snowfilla or other suitable filler materials, covering the furniture by suitable covering materials, cleaning/removal of white washing splashing and dropping from floors, doors & windows, electrical fixtures, etc., all complete as per specifications and as directed by the Engineer-in-charge.
50Painting all internal faces of walls / plastered surfaces with one coat ofAcrylic Emulsion paint of make Asian (Tractor) / Berger (Bison)or other approved equivalent make of approved shade including preparation of surfaces, applying filler / putty wherever required, cost of all materials, labour, scaffolding, removing nails, brooming down the surfaces for removing cobwebs, smoke dirt, etc., filling the holes, cracks, crevices with Snowfilla or other suitable filler materials, covering the furniture by suitable covering materials, cleaning / removal of splashing and dropping from floors, doors & windows, electrical fixtures, etc., all complete as per specifications and as directed by the Engineer-in-charge. (Note:- The sample shall be got approved by the EIC before making bulk order.)
51Painting allinternal faces of walls / plastered surfaces with Two coat of Interior Emulsion paint of make Asian (Tractor) / Berger (Bison)or other approved equivalent make of approved shade over a coat of interior wall primer of make Asian (Professional) / Berger (BP Primer) or other approved equivalent make including preparation of surfaces by scrapping the existing white wash / colour wash using scrapping machine with dust free vacuum collection system, cleaning the existing white wash/colour wash area, roughening the surface, washing the area thoroughly with lime and soda mix or other approved chemical using high pressure washer, preparing the surface dust free for applying the primer coat,applying approved make wall care putty to make surface smooth without porous by using putty knife and sand papers, the dust accumulated during scrapping shall be collected in appropriate dust bin collector / equipment and disposed with in an initial lead, etc., all complete as per specification and as directed by Engineer-in-charge.(Note: The sample shall be got approved by the EIC before making bulk order.)
52Providing Painting over all exposed surfaces at all heights over rough cast plaster/plain plaster with Two Coats of premium exterior emulsion paint ofmake Asian (APEX - Dust proof exterior emulsion) / Berger (Anti dustt weather coat)or other approved equivalent make of approved shade over a coat of exterior wall primer of make Asian / Berger or other approved equivalent make including preparation of surfaces, curing, scaffolding etc., all complete as per specifications.
53Painting over Plain Plaster at all lifts.
54Painting over Roughcast Plaster at all lifts.
55Providing painting over all exposed surfaces at all heights over rough cast/plain plaster with One coat of premium exterior emulsion paint of make Asian (APEX - Dust proof) or other approved equivalent make of approved shade or match with existing shade over the coat of Highly flexible cementious two component coat water proofing treatment system over the coat of bond coat including making surface free from dirt/oil/other materials by scrapping the surface, removal of loose/ cracked mortar, filling the cracks using approved crack fillers, filling/injection/ grouting the cracks/joints where ever required with polymer modified cement mortar using admixtures, scaffolding, etc., all complete as detailed below as per manufacturer specifications and as directed by the Engineer-in-Charge. i)  Surface preparation: Remove the existing coatings, paints, etc., Seal the surface cracks by cutting "V" shaped grooves and filling with crack & using seal compound. Clean the surface thoroughly to remove the dirt"s and contaminates and keep dry prior to the primer application, debonded or weak plaster must be replaced with polymer modified mortar. ii)  Bond Coat (1st Coat) : Applying Base primer bond coat with of make FAB chemical (MIXBond AC) or Bostik (Boscocem 476) over the existing surface. Mixing ratio consumption and application procedure shall be as per manufacturer specifications. iii)  Highly flexible cementious water proofing coat (2nd & 3rd Coat): Applying 2 component waterproofing coating of make FAB Chemical (Mixguard AC) or Bostik (Boscolastic). Duration between these two coats shall be minimum 4 hrs. Mixing ratio of chemicals, consumption and application procedure shall be as per manufacturer specifications.
56For one coat of exterior emulsion over Plain Surface iv)  One coat of external wall primer (3rd coat): Applying one coat of external wall primer of make Asian or other approved equivalent,consumption and application procedure shall be as per manufacturer specifications. v)  One coat of premium exterior emulsion paint (4th coat): Applying one coat of premium exterior emulsion paint of make Asian (APEX - Dust proof) or other approved equivalent make of approved shade or match with existing shade. Mixing ratio of paint, consumption and application shall be as per manufacturer specifications. Note: Cost for plastering will be paid for separately under relevant item.
57Providing Terracotta Paintingover compound wall/Honey comb wall / Roof tiles / facia tiles at all heights with one coat ofAcrylic Emulsion paint ofmake Asian (APEX - Dust proof exterior emulsion) / Berger (Anti dustt weather coat) or other approved equivalent make of approved shade and colour including cleaning, preparation of surfacesby scrubbing / cleaning the fungus / stains, cleaning with water, filling the cracks with approved crack filler, curing, scaffolding etc., all complete as per specifications. Note:- 1) The samples should be got approved by the EIC before placing.
58Painting with flexible polymer modified cement based anti-dampness coating for interiors using Asian Paints Damp Block or other approved equivalent make including preparation of affected surface, removing old paint / putty using wire brush / chisel to expose cement plaster, apply self priming coat of damp block (1:1 ratio diluted in water) and apply 2 coats of damp block (diluted with water in 3 part powder : 1 part water ratio) using a putty knife or a trowel to achieve total coverage of 7.5 sqft/ kg, finishing the surface smooth, etc., all complete as per specifications and as directed by Engineer.
59Painting for wood work with one coat of synthetic enamel paint of approved colour and make including preparing the surface for receiving the paint by scraping, rubbing, applying wood filler, wood putty, making surface smooth, etc., as per specifications.
60Painting for window grills/ shutters/ gates with one coat of anti-corrosive paint of approved colour and make including preparation of surfaces for receiving the paint by scraping, rubbing, labour, scaffolding, etc., all complete as per specifications.
61Applying anti-termite chemical for new wooden frames of windows / doors/ ventilators by spraying or brushing with two coats of Dursphan / Durmat or other approved equivalent make of anti-termite chemical at the ratio of 1:19 [one part of chemical and 19 parts of kerosene] over the wood and contact masonry surface, etc., all complete as directed by the Engineer-in-charge.
62Numbering the houses by writing letters/ numbers/ symbols with enamel (Marker) paint of approved colour on the face of the wall/ Display Boards using templates and stencil cutting, including base painting, cost of materials, labours, scaffolding, applying wall care putty wherever required to making surface smooth, etc., all complete as per specification and as directed by the EIC.
6375mm size letters of approved font- maximum three digit letters in each.
64Dismantling Plain cement concrete/Brick bat coba at all lifts including clearing and depositing the same with a distance of 100 metres as directed by Engineer-in-charge.
65Dismantling Reinforced cement concrete at all lifts including clearing and depositing the same with a distance of 100 metres as directed by Engineer-in-charge.
66Dismantling Brick workin cement mortar at all lifts including clearing and depositing the debris within a distance of 100 metres all as directed by Engineer-in-charge.
67Dismantling of Tile work in floors, walls and roofs laid in CM upto 25mm thick including removal of tiles, stacking as directed, disposal of debris within a initial lead of 100m, etc., allcomplete.
68Dismantling of 15mm to 40mm dia G.I /PVC pipe upto floor V level including scaffolding, removing the pipes and fittings without causing any damage toexisting stock pipes, stacking of retrieved pipes at Departmental stores, etc., all complete as per directed by Engineer-in-Charge.
69Disposal of surplus excavated earth / Debris by collecting, loading, transporting by mechanical means and unloading them at places as shown by the Department within a lead specified below and levelling, etc., all complete as per specifications and as directedby the Engineer-in-Charge. Note: 1) The rates in respect of this item are applicable for the NET Quantities arrived at after making deductions for voids @ 20% in respect of soil and @ 50% in respect of rock from the corresponding stack / truck measurements. 2) The earth shall be dumped well inside the dumping yard and not over approach pathway road.
70Upto 1 Km or part thereof
71Exceeding 1 Km but not exceeding 2 Kms
72Replacing the existing wood work by supplying, manufacturing and fixing of Teakwood frames and architraves for doors, windows, ventilators, etc., made out of best quality Class-II teakwood scantlings with necessary holdfast / anchor fasteners, wooden plugs and screws for fixing it to the various openings including removing the old door frame/shutter with all fittings, refixing the shutter to the new frame, finishing the sides with plastering white/colour washing to match with existing surface, painting the new wood with two coats of synthetic enamel paint over a coat of primer etc., and returning the retrieved old materials to GSO civil maintenance stores, etc., all complete as per the specifications and as directed by Engineer-in-charge.
73Providing and fixing Wardrobe shutters of single/double leaves made out of 8mm thick Cement bonded particle board of `Bison Panel" or approved equivalent make panels with second class teak wood frame of size 40x40 mm alround with lock rail of size 40x32 mm at the centre for each leaf including removing the old damaged shutter and returning the damaged shutter to GSO stores etc., complete all as per specifications and as directed by the Engineer-in-charge.
74Repairing the cupboard shutters by removing the shutters from the existing position with all furniture fittings, removing the damaged portion of plywood panels from the shutters and replacing with 4mm thick commercial plywood including cost of cutting, finishing the edges and refixing the shutters in position with all the existing fittings and painting with two coats over one coat of synthetic enamel paint of wood primer etc., complete all as per specifications and as directed by the Engineer-in-charge.
75Repairing and refixing of PVC shutters including removing the shutter, jointing the loose joints with PVC solvent or synthetic resin adhesive & screws, refixing the shutter, etc., all complete as per specification and as directed by the Engineer-in-charge. (Note: Cost of furniture fittings will be paid for separately under relevant item.)
76Repairing, modifying the following size of panelled door shutters using old wood/retrieved panelled doors and fixing including removing the damaged styles, rails, panels if any and fabricating with available old wood to required size and shape, removing the old painting wherever required,fixing in position with all requiredfurniture fittings, painting with one coat of synthetic enamel paint, etc., all as per specification and as directed the Engineer-in-charge. (Note:- Retrieved old wooden styles, rails and panels will be supplied from department store at free of cost)
77Upto 650mm wide and 2100mm height
78From 650mm to 950mm wide and 2100mm height
79Supplying and fixing of factory made Solid PVC foam door frame of approved make with suitable rebate for shutters (Profile FP-6030) including the joints shall be mitred & Jointed with self driven self tapping screws of size38 mm x 4 mm and made by SP 5 epoxy seal and fevikwik / solvent, fixing the frame to wall with suitable dia. & length anchor fastener including removing the existing damaged door frame stacking at GSO stores, finishing the door and wall joints using CM 1:5 plaster to match with existing surface and painting with two coats of acrylic emulsion paint, etc., all complete as per manufacturer specifications and as directed by the Engineer-in-Charge.
80Supplying and fixing in position single leaf Factory made flush door shutter of 25mm thickness of PVC integral foam sheet of make M/s. Jain Irrigation Systems Ltd. (Ex-cel sheet) or other equivalent approved make of white colour for flush door shutter including providing recessions for hinges, fixing with following fittings over the door frame using required fasteners, finishing all edges with mixture of PVC powder & solvent for smooth finish, etc., all complete as per specification and as directed by the Engineer-In-Charge. The door shutter shall be fixed with the following hardware fittings: - a)4 Nos. of 75 mm long stainless steel butt hinges ofGARGbrand bearing ISI mark with suitable stainless steel screws. b) Two numbers of 125mm long anodised aluminium Dhandle of make Classic/Crown or approved equivalent as per IS - 208 bearing ISI mark with suitable CP screws. c) Two numbers of 75mm long anodised aluminium baby latch type/cranked type tower bolt with suitable CP screws. d) One number of 50mm long solid PVC door buffer with 75mm long CP screws. Note: -1) All furniture fittings shall be of approved quality and make. 2) The rate quoted shall be inclusive of fixing of door shutters with required hardware fittings as detailed above. 3)The PVC Integral Foam shall be factory manufactured solid section of light weight sheet with fine & homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides. The sheet shall have density of 500 - 600 Kg/Cum, water absorption less than 1% and tensile strength greater than 11 MPa. 4) The entire door shall be jointless shutter. 5) The sizes shall be approximately 700 mm x 2100mm, however exact dimensions shall be measured at site before manufacturing.
81Supplying and fixing in position single leaf/double leaves of following thick non decorative type factory made Wood Polymer Composite (WPC) solid door shutters of approved make having density of 600 - 800 Kg/Cum, water absorption less than 1% and tensile strength greater than 12 MPa including providing aluminium lipping / Teak wood all-round if required, fixing the lipping with suitable adhesive, fixing required hardware fittings, fixing door using required screws, etc., all complete as per specifications and as directed by Engineer-In-Charge. [Note: Cost of Door frame, hardware fittings and Aluminium / Teak wood lipping will be paid for separately under relevant item.]
8230mm thick WPC door
8335mm thick WPC door
84Attendingminor repair works in doors, windows, ventilators and MS Grill mesh doors of various types of vacant houses by servicing the fittings and replacing the wornout fittings if any, refixing the same, and also other carpentry related complaints if any etc., complete all as directed. Note: 1) The rate quoted shall be for each door/window. 2) Retrived furniture fittings if required will be supplied by the department at free of cost (or) new furniture fittings will be paid for separately under relevant item.
85Door"s and Cupboards
86Windows other than kitchen window
87Windows at kitchen
88Ventilators
89MS Grill door frame and shutters
90Supplying, fabricating and fixing Steel Grills / Guard bars of required pattern and size for Windows/Ventilators, Staircase Hand Rails, etc., fixed to openings/wooden frames at site, comprising of MS square bars/MS rounds/MS flats, etc., including fixing with necessary wood screws for fixing grills/by welding in steel windows, embedding the guard bars in wall, painting with two coats of anti corrosive paint of approved colour and make over a coat of red oxide zinc chromate primer, etc., all completed as per specification.
91Replacing the damaged existing mesh by providing and fixing Fly proof Stainless Steel (Grade 304) wire gauze of 0.4mm dia wire and 1.4mm aperture on both sides of approved quality and make over partly panelled Door / Grill door including removing the damaged mesh, fixing the new mesh with second class Teak wood beading or Aluminium frame work, cost of screws, nails, rawl plug, etc., all complete as per specification. [Note: Cost of frame work i.e., Steel or wood or aluminium, will be paid for separately under relevant item]
92Reinforcing the existing steel grills by providing extra legs of 10mm dia. MS bar including drilling holes in the window frames, inserting the legs of length upto 150mm welding the legs with existing grills using portable welding set at site, finishing the surface, etc., all complete as per specification and as directed by Engineer-in-charge.
93Supplying and fixing glazed shutters having 65 x 32mm second class teakwood frames and 4mm thick clear/grounded glass for windows / ventilators including providing and fixing 19x12mm size teakwood beading for fixing glass, fixing shutter, removing the damaged window shutters, returning them to maintenance stores all as per specifications and as directed by the Engineer-in-charge.
94Fabrication and fixing of doors, windows, ventilator frames, window shutters, ventilator shutters using the available old wood by cutting to required length, jointing, fabricating to required size and fixing with necessary hold fasts including removing the old painting, removing the damaged wood works, finishing the wall surfaces, white washing, applying two coats of synthetic enamel paint over a coat of wood primer, etc., complete all as directed by Engineer-in-charge. (Note:- Retrieved old wooden frame and shutters will be supplied from department store at free of cost)
95Door frames
96Window frames
97Ventilator frames
98Window shutters
99Ventilator shutters
100Replacing the existing damaged window / ventilator glass panes by supplying and fixing in position 4mm thick plain/grounded glass of make Saint Gobain or equivalent with necessary teakwood beading, pin nails, putty, etc., by using the existing removed beading to the possible extent and supplying and fixing balance beading if any, including cost of beading, nails, putty, etc., and transporting the removed broken glass pieces and disposing safely at places as shown etc., all complete as per specifications and as directed by the Engineer-in-charge.
101Window / Ventilator glass of various sizes
102Louver glass of size 600 to 750mm long, 125mm wide and 4mm thick grounded glass.
103Modification of existing Glazed Windows to accommodate 1.50 Ton Air conditioner of size 700x500mm by cutting the existing window and introducing 1300 to 1500mm long second class teak woodof size 100x50mmhorizontally and using the retrieved wood for vertical support, including altering/ fixing the existing shutter and grill of existing pattern to required size and shape using the dismantled materials wherever possible for top portion, painting with two coats synthetic enamel paint to match with the existing surface over a coat of wood primer etc., all complete as per specification and as directed by the Engineer-in-charge.
104Replacing the old night latch by supplying and fixing in position of New Ultra Verti bolt XL+ of "Godrej" (1CK Texture Brown) or approved equivalent make operable by key from outside and by knob from inside with four keys including removing the old night latch and returning the damaged night latch to GSO stores, fixing the new vertibolt using retrofit adopter over the existing night latch hole, etc., all complete as directed by Engineer-in-charge. (Note: The lock shall be got approved by the Engineer before making bulk order)
105Supplying and fixing of following spares for Ultra verti bolt (Godrej - 1CK - Texture Brown (or) Ultra Verti bolt XL+ - Texture Brown) including servicing the lock, replacing the damaged part, etc., all complete as directed by Engineer - In - Charge.
106PIN Cylinder assembly
107Providing and fixing IS : 12817 marked stainless steel butt hinges (Heavy weight) of make GARG or approved equivalent make including fixing with suitable stainless steel screws and including removing the damaged fittings and returning the retrieved old materials to GSO Civil Maintenance stores, etc., all complete as per specification.
108125 x 65 x 2.50mm
109100 x 59 x 2.50mm
11075 x 47 x 2.50mm
111Providing and fixing Aluminium 75mm tower bolts / baby latch ofmake Classic or Crown or Hanoi or Ashokaincluding anodised transparent or dyed to required colour or shade, fixing with necessary CP screws, etc., all complete as per specification.
112Providing and fixing IS:208 marked aluminium handles of "Classic or Crown or Global" or approved equivalent make including anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade, fixing with necessary SS screws etc., all complete as per specification.
113125mm x 12mm dia.
114100mm x 10mm dia.
115Providing and fixing IS:204 marked Aluminium tower bolts ofmake "Classic or Crown" or approved equivalent make including anodised transparent or dyed to required colour or shade, fixing with necessary CP screws, etc., all complete as per specification.
116250 x 12mm
117150 x 12mm
118100 x 10mm
119Providing and fixing ISI marked Aluminium sliding door bolts (Aldrops) of size 250x16mm "Classic or Crown or Global" or approved equivalent make as per IS 2681 including anodised transparent or dyed to required colour or shade, fixing with 5 Nos of clip and staple with necessary CP screws etc., all complete as per specification.
120Providing and fixing anodised Aluminium hook and eye with suitable screws including removing the damaged fittings and returning the retrieved old materials to GSO Civil Maintenance stores, etc., all complete as per specification.
121Hook and eye 250 x 6mm
122Hook and eye 75mm long
123Providing and fixing anodised aluminium 90mm hasp & staples ofapproved make conforming to IS 363 including fixing with suitable screws including removing the damaged fittings and returning the retrieved old materials to GSO Civil Maintenance stores, etc., all complete as per specification.
124Providing and fixing 50mm long and 40mm dia. PVC solid door buffer with 75mm x 10mm SS screws and cup washers.
125Providing and fixing Brass body with satin nickel finish Door Viewerof make Godrej or Prayag or other approved make suitable for 35-40mm thick door shutters including fixing in door as directed by Engineer-in-charge.
126Providing and fixing Door Safety chain of approved shape with SS304 grade chain and satin nickel polished of make Godrej or Prayag or otherapproved make including fixing as directed by Engineer-in-charge.
127Providing and fixing 12mm dia. heavy quality anodised Aluminium Hangers of length not exceeding 450mm for wardrobes including removing the damaged hanger, fixing the new hanger with rawl plugs and suitable cadmium plated MS screws along with bothside anodised aluminium end brackets, returning the existing damaged hanger to store, etc., all complete as directed by Engineer-in-Charge.
128Repairing and refixing the existing looking mirror with fiber reinforced plastic frame including replacing the worn out rubber gasket with new gasket, replacing the damaged PVC/MDF backing with 6mm thick BWR plywood with wall fixing screw slots two nos each on vertical and horizontal side, painting with one coat of synthetic enamel paint to match with the existing surface fixing it to the wall with necessary screws, etc., all complete as per specification and as directed by the Engineer-in-charge. [Note: The required Looking mirror and frame will be issued by the Department at free of cost.]
129Providing and fixing in position of 5mm thick looking mirror of make "SAINT GOBAIN" or approved equivalent make of an overall size of 600 x 450mm with fibre reinforced plastic frame with gasket and 6mm thick BWR plywood backing with screw slots two number each on horizontal and vertical sides and fixing to the wall with necessary screws and including returning the old damaged mirrors to GSO Civil Maintenance stores, etc., all complete as per specification and as directed by the Engineer-in-charge.(Note : The looking mirror shall be got approved by the Engineer-In-Charge before making bulk order)
130Replacing the wornout/damaged PVC connection by providing and fixing of 15mm x 450mm long PVC connection of approved make and confirming to IS specification both Cold and Hot water including PVC checknuts and nylon washers on both ends, fixing with GI Specials if required, returning the retrieved wornout fittings to GSO civil maintenance stores etc., all complete as per specification and as directed the Engineer-in-charge.
131Providing and fixing of following heavy quality CP brass fittings of makeMetro - S (or) "Prayag - (Neptune Series)"or other approved equivalent make conforming to IS 8931 - specification and bearing ISI mark including fixing with required SS extension nipple/GI special if required, fixing wall flange etc., all complete as per specification and as directed by the Engineer-in-charge.
13215mm CP brass Long Body Bib cock with casing cup
13315mm CP brass short body Bib cock with casing cup
13415mm CP brass Two way Bib cock with casing cup
13515mm CP brass pillar cock
13615 mm CP brass angle cock with casing cup
13720mm CP brass Concealed stop cock
13820mm CP brass Open stop cock
139Providing and fixing of heavy quality CP brass fittings ofMetro - S (or) "Prayag - (Neptune Series)"or approved equivalent make conforming to IS-8931 specification including fixing with SS extension nipple if required, wall flange etc., all complete as per specification and as directed by Engineer-in-charge.
14015mm Sink cock (J - Bend type)
141Providing and fixing of heavy quality CP brass fittings ofMetro - S (or) "Prayag " or approved equivalent make with wall flange including fixing with suitable SS valve/cupetc., all complete as per specification and as directed by Engineer-in-charge.
14232mm CP brass waste coupling (Droplets Series- Heavy )
143100mm Square CP chrome finish shower with 300 shower arm - ABS body chrome plated [Drizzle Series]
14432mm PTMT Bottle trap
145Replacing spares for CP brass fittings such as bib tap, stop cock, pillar cock, push cock, Concealed stop cock , etc., by supplying and fixing the following spares including removing the fittings without interrupting the water supply, servicing the fittings by replacing the wornout spares with new spares, refixing the same etc., all complete as directed by the Engineer-in-charge.
14615mm brass spindle suitable for "Metro"/"Prayag" make
14715mm brass spindle suitable for "Waterman"/"Peaco" make
14815mm brass spindle suitable for "JAQUAR / PARRYWARE" make
149Providing and fixing of following CP brass fittings to fix the sanitary fittings such as bib cock, angle cock, etc., of make Prayag or other approved make etc., all complete as directed by the Engineer-in-charge.
15015mm dia. CP/SS round wall flange
15115mm dia. 25mm length CP extension nipple (Heavy)
152Attending repairs to CP brass fittings such as bib cock, stop cock, pillar cock, push cock etc., including removing the fittings without interrupting the water supply, servicing the fittings by replacing the wornout washer if any,refixing the same, etc., all complete as directed by the Engineer-in-charge.
153Labour charges for fixing the retrieved Bib tap / CP brass fittings including providing SS extension nipple, wall flange, fixing the fittings, etc., all complete as directed by the Engineer-in-charge. [Note: Required CP brass fittings will be issued by the Department at free of cost.]
154Providing and fixing heavy quality 600mm CP Towel rail of "Prayag" (Contabile series) or approved equivalent make with wall flange including suitable CP screws all complete as per specifications and as directed by Engineer-in-charge.
155Providing and fixing 300mm long plate fixed with three / four prong type anodised aluminium robe hooks approved make with suitable cadmium plated MS screws.
156Supplying and fixing in position best vitreous China ware wash hand basin of size 560x440mm Inoya / 550x450mm Indus/ 550x400mm oxford of Parryware or approved equivalent make of white colour including fixing with pair of CP multipurpose rag bolt/pair (or) suitable cast iron supports painted with two coats of synthetic enamel paint over a coat of red oxide primer with necessary screws, cost of cement, etc., all complete all as per specification and as directed by the Engineer-in-charge.
157Refixing the existing wash basin by removing the existing wash basin and refixing the washbasin including removing the CI brackets, old decayed teakwood plugs, fixing new teakwood plugs to wall at required height, re-fixing with new MS brackets with necessary new screws after painting with two coats of synthetic enamel paint and connecting to the inlet and outlet connection by using the existing accessories, providing GI / CPVC specials if required etc., all complete as directed by the Engineer-in-charge.
158Labour charges for cleaning the existing stained ceramic sanitaryware like EWC / IWC pan, washbasin, sink etc., by using hydrochloric acid of 30% concentration,soap oil, washing powder etc. without damaging the ceramic ware including cost of hydrochloric acid, soap oil, washing powder, etc., complete all as directed by the Engineer-in-charge.
159Providing and fixing high level/Low level polymer DUAL flushing cistern of 3/6 litres capacity of make "PARRYWARE/ HINDWARE model SLIMLINE" or approved equivalent conforming to IS: 7231 including fixing cistern at required height and level with necessary TW wall plugs, screws, connecting inlet and outlet, connecting the cistern and closet with suitable dia. PVC pipes and fittings conforming to IS:4985 etc., complete as per standard specifications. Note: During the above process proper care shall be taken to protect the existing IWC/EWC if any damage is taken place in IWC/EWC contractor shall replace with new IWC/EWC free of cost.
160Refixing the existing high / Low level flushing cistern along with telescopic pipe by removing the existing cistern with telescopic pipe and refixing the flushing cistern with necessary PVC brackets and support at required heightincluding connecting the cistern and closet with suitable 40mm dia. PVC pipe with necessary specials, modifying the water line if necessary, dismantling floor for removing the damaged telescopic pipe and restoring the same to its original condition etc., all complete as directed by the Engineer-in-charge.(Excluding cost of PVC pipe and GI pipe if required which will be paid for separately under relevant item) Note: During the above process proper care shall be taken to protect the existing IWC/EWC if any damage is taken place in IWC/EWC contractor shall replace with new IWC/EWC free of cost.
161Repairing the flushing cistern of "Parryware - Slimline" by supplying and fixing the following spares to flushing cistern including removing the existing flushing cistern, replacing the worn out spares with new spares, applying two coat enamel paint to exposed surface of flush tank and refixing the same in original position with working condition etc., all complete as directed by the Engineer-in-charge.
16215mm dia. PVC ball cock with suitable PVC float(Inlet Assembly)
16332mm dia. PVC syphon (Outlet Assembly)
16415mm PVC handle knob without pulling rope.
16550mm dia. rubber washer
166Providing and fixing PVC Nahani trap of approvedmake conforming to the relevant IS code, heavy quality of self cleaning design with 125mm dia. round (or) 125mm square PVC grating with perforated holes on top, including chipping the existing floor concrete, exposing the damaged Nahani trap, fixing new Nahani trap, embedding in cement concrete 1:2:4, forming circular holes by providing and fixing 110mm OD PVC pipes of required height upto floor level, jointing the outlet pipe, leveling and rendering smooth, making good the floor and wall etc., complete as per specifications. (Note: Rate shall be inclusive of cost of PVC pipe and embedding PCC.)
167Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) of 20mm (Concealed on wall) Nominal Bore dia. pipes (Class-I) SDR-11 of approved make conforming to IS 15778 having thermal stability for hot and cold water supply including providing CPVC plain and brass threadedfittings, fixing the pipe with concealed clamps at 1 m spacing, jointing of pipes and fittings with 1 step CPVC solvent cement, cost of cutting chasses and making good the same, testing of joints complete, etc., all complete as per specification and as directed by Engineer In-Charge. (Note: Concealed work including cutting chases and making good the wall, etc.,)
168Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (Class-I) of SDR-11 of approved makeconforming to IS 15778 having thermal stability for hot and cold water supply including providing all CPVC plain and brass threadedfittings, fixing the clamps at 1m spacing, jointing of pipes and fittings with 1 step CPVC solvent cement, testing of joints, etc., all complete as per specification and as directed by Engineer In-Charge. (Internal work-Exposed on wall)
16920mm dia Nominal size
17025mm dia Nominal size
17140mm dia Nominal size
172Supplying, fixing and testing of following dia CPVC Ball Valve Heavy duty of approvedmake including fixing over CPVC pipe using 1 step CPVC solvent cement, testing of joints, etc., all complete as per specification and as directed by Engineer In-Charge.
17325mm dia. CPVC Ball valve
17440mm dia. CPVC Ball valve
175Replacing the following sizes of existing damaged PVC pipes with new PVC pipe of 10 Kg. per sq.cm pressure pipe confirming to IS 4985 of approved make bearing ISI marking including all types of specials, cutting and removing the damaged portion of the existing PVC line, replacing new PVC pipe for flush tank & kitchen waste line with suitable jointing compounds, necessary opening/ chasing of the wall, flooring, etc., without interupting the regular water supply,cost of necessary GI clamps, screws, teakwood plugs, packing pieces, restoring the same after completing the job to its original condition etc., all complete as per specification and as directed by the Engineer-in-charge.
17640mm O/D PVC pipe
17750mm O/D PVC pipe
178Replacing the existing damaged IWC pan/Orissa pan by providing and fixing in position offollowing size ORISSAPAN of approved make white glazed vitreous china ware ORISSAPAN WATER CLOSET of PARRYWARE or equivalent make with "S" or "P" trap with all jointing materials including removing the damaged IWC/Orissapan, chipping out the floor, concrete, brick wall, brick bat etc., making holes in masonry, fixing the new Orissapan, jointing the pipe & Trap with Lip ring of "PRINCE" or approved make, reconstructing the same, encasing the pan and trap with brick jelly concrete 1:2:4 and back filling extra space with river sand/brick jelly concrete,including disposal of debris within 2kms lead, cost of cement required for the work etc., all as per specifications and as directed by the Engineer-in-charge. Note: 1) Cost of floor finishing will be paid for separately under relevant item. 2) Brick jelly concrete for back filling extra space with broken jelly concrete will be paid for separately under relevant item.
179Orissapan of size 580x440mm
180Replacing the damaged CI soil waste pipe by supplying, laying and fixing of PVC pipe lines laid, embedded under floor slab and fixed to walls wherever required using SWR uPVC pipes - Type B (suitable for soil and waste discharge system having wall thickness of minimum 3.2 to maximum 3.8mm) conforming to IS:13592 - latest edition with ISI mark of approved make and PVC pasting type or Ring type specials such as door bends, door tees and cowls etc. heavy quality for soil waste or vent or antisyphonage PVC pipe including removing the damaged CI pipe, chipping/removing the embedded pipe if any, fixing the new PVC pipe with suitable clamps over Teak Wood packing pieces, restoring the same to its original condition, disposal of debris within a initial lead, stacking of retrieved CI pipes at GSO stores etc., all complete as per specification and by the Engineer-in-charge.
18190mm OD SWR-uPVC pipes and specials (Type B)
182110mm OD SWR-uPVC pipes and specials (Type B)
183Replacing the existing damagedRainwater down take pipes by Providing and jointing of SWR uPVC pipes - Type A - 110mm OD (suitable for ventilation work and rain water applications) of approved make conforming to IS: 13592 - latest edition with ISI mark including moulded fittings/specials such as bends, shoes, etc., jointing with seal ring conforming to IS - 5382 leaving 10mm gap for thermal expansion, fixing to the wall with adequate no. of PVC clips for rain water down take pipes etc., including removing the damaged pipe, chipping / removing the embedded pipe in roof concrete, packing the existing holes in wall surfaces fixing the new PVC pipe with suitable clamps over MS supports, restoring the dismantled roof concrete after fixing new PVC pipe with CC 1:2:4, finishing around the pipe along with PVC Tail piece at roof level, disposal of debris with in a initial lead, stacking of serviceable/ retrievedpipes at GSO stores, etc., all complete as per specifications and as directed by the Engineer in charge. (Note:- PVC tail piece will be paid for seperately under relevant item.)
184Supplying the following dia. of PVC specials ofapproved make with ISI mark suitable for class-III PVC pipe (6kg/sq.cm) including transporting, unloading at work site etc., all complete as per specification and as directed by Engineer.
185110mm OD PVC Tail Piece
186Providing and fixing of Stainless Steel 304 grade 150mm Square/Circular grating of make "Prayag" or other approved equivalent make including removing the damaged grating, fixing, finishing the surface to match with existing surface, etc., all complete as per specifications.
187Refixing of dislocated 110mm dia. SWR pipes from its original position including providing new Teak wood plug/packing piece, fixing with new GI clamp with necessary screws, etc., all complete as directed by the Engineer-in-charge.
188Raising the height of existing manholes of following sizes by using 230mm thick brick masonry in CM 1:6 and plastering with CM 1:5, 12mm thick including removing and refixing the manhole cover, disposal of debris, white washing two coatsetc., all complete as per specification and as directed by the Engineer-in-charge.
189300x300mm Gully chamber upto 300mm Hieght
190600x450mm manhole upto 300mm
191900x600mm manhole upto 300mm
192Providing and constructing GULLY CHAMBER of internal finished size 300 x 300mm including providing, supplying and fixing 150 x 150mm (±10mm) PVC Gully trap with PVC grating at top of approved make including excavation in all types of soils, backfilling, embedding the trap in plain cement concrete 1:4.5:8 using 40mm size granite aggregates and constructing thechamber above the embedded PVC with 110mm thick (plus or minus 5mm) bricks in Cement Mortar 1:5 with well burnt stock bricks, plastering over both internal and external faces of brick work with Cement Mortar 1:3; 12mm thickfinished smooth with a floating coat of neat cement on both faces, providing and fixing 400 x 400 x 25mm precast slab in reinforced cement concrete of 1:2:4 using 12mm and below hard broken granite stones including cost of gully trap, chamber etc., all complete as per specification.
193Making connection of drain or sewer line with existing manhole including breaking in to and make good the walls, floors with cement concrete 1:2:4 mix (1cement:2 coarse sand: 4 graded stone aggregate20mm nominal size) cement plastered on both side with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain, etc., complete.
194For pipes 100mm to 230mm diameter
195Clearing light jungle including uprooting of rank vegetation, grass, brush wood, removal of rubbish upto a distance of 100m outside the periphery of the area cleared, etc., all complete as per specification and as directed by Engineer-In-Charge.
196Labour charges for cleaning the external area of vacant quarters by cleaning, removing cobwebs, sweeping, picking up the plastics, polythene papers, garden wastes, dry leaves and all other waste materials, conveying and disposing the waste, etc., all complete as directed by Engineer in charge.
197Labour charges for removing choke from Gully/Inspection chambers from residential & Non residential buildings including removing/disposing the removed waste/debris away from the buildings within a lead of 100 mtrs., cost of all tools and plants, safety materials required for this item, etc., all as directed by the Engineer-in-charge.
198Labour charges for cleaning the internal area of vacant quarters by brooming down cobwebs, removing the dust, waste materials including cleaning, sweeping & washing the entire floor area cleaningusing cleaning powder & soap oil, the ceramic wares using acid, cleaning louver glass and window glass, cleaning waste water line from various dia of internal traps to gully chambers collecting the waste materials,conveying by suitable means, disposing/depositing at places shown by the Engineer-in-charge. (Note:Cleaning shall be carried out with out causing any damage to existing fittings / fixtures.)
199Category - C & SA
200ELECTRICAL ITEMS: Supply and Embedment of following sizes of flush mounting POWDER COATED TPN/SPN DB Enclosures with Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires etc. at suitable depth in brick work as per the detailed specification and as directed by the Engineer-in-charge.
201SPN, 4 Way Distribution Board with all accessories, cat No: 507610
202SPN, 12 Way Distribution Board with all accessories, cat No: 507612
203Removing and Re embedment of following size of flush mountingPOWDER COATED DB Enclosures with Double Door consisting of Phase, Neutral and Earth Bus and interconnecting wires etc. at suitable depth in brick masonry work as per the detailed specification and as directed by the Engineer-in-charge.
204SPN 12 Way Distribution Board with all accessories
205Assembling, installation, testing and commissioning of MCB DB enclosure already embedded in the wall including supply of Engraved Circuit Identification Plate and Danger Board as per the detailed specification for the following size of MCB DBs.
206SPN, 12/16 Way or TPN 4/6 Way Distribution Board
207Supply fixing testing and commissioning of the following RCCBs & MCBs on Distribution Boards as per the detailed specification.
208RCCB DP 63A sensitivity 30mA, TYPE Hpi
2096-32 Amps SP MCB (Type-C)
210Supply and Embedment of 50mm Deep, Square/Rectangular Concealed type and GI double earthed modular metal boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification.
211ONE/TWO Module
212THREE Module
213FOUR Module
214SIX Module
215EIGHT Module
216TWELVEModule
217Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required.
218ONE /TWO Module Front Modular Plate. (Suitable for 1 / 2 Module Box )
219THREE Module Front Modular Plate. (Suitable for 3 Module Box)
220FOUR Module Front Modular Plate. (Suitable for 4 Module Box)
221SIX Module Front Modular Plate.(Suitable for 6 Module Box)
222ONE Module Blank Plate (White)
223EIGHT Module Dummy Front Modular Plate (Suitable for 8 Module Box)
224TWELVE Module Dummy Front Modular Plate (Suitable for 12 Module Box)
2251 No. of 1 Module,10 A, 1 Way, Single Pole Switch
2261 No. of 1 Module,10 A, 1 Way, Single PoleBuzzer / Calling Bell Switch.
2271 No. of 2 Module, 6 A, 5 Pin Shuttered Socket
2281 No. of 2 Module, Step Type Fan Regulator
229ONE Module Front Modular Plate along with 1 No. of 1 Module TV Co-axial Socket Outlet.
230TWO Module Front Modular Plate along with 2 Nos of RJ11 Telephone Socket with Shutter.
231Supply and installation of1 No. of 240 V, 20 A, 2P+E Metal Clad Socket on already embedded THREE Module G.I box along with suitable Plug Top and THREE Module Front Dummy Plate for Geyser Point as directed by Engineer in charge and per the detailed specification.
232Supply and installation of 1 No. ofTWO Module Front Modular Plate with 1 No. of 6 A, Indicator Lamp + 1 No. of 1P, 20 A, Mini MCB, "C" series, 3 kA for Geyser Control as per detailed specification.
233Supply, embedment and flush mounting of 1 Phase, 20A MC socket box with 20A SP MCBof Metal Clad Socket in sheet steel enclosure with Plugs and Socket including chipping and finishing as per the detailed specification.
2341 No. of THREE Module Front Modular Plate along with 1 No. of 6 A Modular Switch and 1 No. of 6 A, 5 Pin, Shuttered Socket as per the detailed specification.
2351 No. of THREE Module Front Modular Plate along with 1 No. 16 A Modular Switch and 1 No. of 6/16 A, 3 Pin, Combined Socket as per the detailed specification.
236Supply, transportation, installation, testing and commissioning of 1 x 36 W Patti type - Striplite for Wall/Ceiling mounting including supply and fixing of 1 x 36 WTLD Lamp along with supply of necessary fabricated brackets to mount the light fitting and supply and fixing of 6 A, 240 V, 3 Plate, Ceiling rose as per detailed specification and as directed by Engineer in Charge.
237Supply and installation of 6 A, 230 V, Angle Lamp Holder along with PVC Junction Linker as per detailed Specification and as directed by Engineer in Charge.
238Supply and installation of Buzzer along with PVC Junction Linker as per detailed specification and as directed by Engineer in Charge.
239Supply, installation, testing and commissioning of 6 A, 240 V, 3 Plate, Ceiling rose with PVC Junction Linker as per detailed Specification and as directed by Engineer-in-charge.
240Supply, installation, testing and commissioning of following Exhaust Fans as per the detailed specification.
241Supply, installation, testing and commissioning of 230 mm Dia, Medium duty, Wall Mounted Exhaust Fan with Double Ball bearing including required wall opening, Supply and fixing of suitable RCC colour and finishing of the wall, embedment of Stainless Steel Bolts (4 Nos. of 6 mm x 60 mm) for mounting of Exhaust Fan on the wall and supply and fixing of Stainless Steel Mesh (350 mm x 350 mm) along with supply and connecting of 3 Core, 1.0 Sq.mm PVC insulated & sheathed copper flexible cables of required length and along with supply and fixing of 6 A, 3 Pin, Plug top, refer Drg No. GSO/ECS/KTS/EXF/03 for SS meshas per the detailed specification and as directed by Engineer-in-charge.
242Supply, installation, testing and commissioning of 230 mm Dia, Medium duty, Wall Mounted Exhaust Fan with Double Ball bearing on already embedded mounting bolts along with supply and connecting of 3 Core, 1.0 Sq.mm PVC insulated & sheathed copper flexible cables of required length and along with supply and fixing of 6 A, 3 Pin, Plug top as per the detailed specification and as directed by Engineer-in-charge.
243Supply, Installation, testing and commissioning of following sizes of ceiling Fans and safety steel rope with 3 Core, 1.5 Sq.mmflexible copper cable including earth connection. Supply and fixing of regulator is not included in the scope of this item.
244Supply, installation, testing and commissioning of following electrical accessories on the existing Hylam sheet fixed over the switch boxes by providing suitable cut-out to fix the accessories as per detailed specification and as directed by Engineer in charge.
2456 A, 240 V,1 Way Switch
2466 A, 240 V, 2 Way Switch
2476 A, 240 V, Bell Push Switch
24816 A/20 A, 240 V, 1 Way Switch
2496 A, 240 V, 2-in-1 Socket
25010/20 A, 240 V, Universal Socket
2516 A, 240 V, Switch Socket Combined
25210/20 A, 240 V, Universal Switch Socket Combined
253100 W, Step type Ceiling Fan Regulator
254Carrying out healthiness check of earthing inside the house and up to EMDB level and healthiness checking of RCCB, MCB, SPN DB and all power points in Category- C and SA type residential quarters as per detailed specification and as directed by Engineer in Charge.
255Supply and installation of laminated Hylam sheet of 3mm thickness over the boxes as per the detailed specification.
256Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.
25732 X 12mm size of PVC Mini trunking
25825 X 12 mm size of PVC Mini trunking
25920 X 12 mm size of PVC Mini trunking
260Supply and Installation of following sizes of Heavy Duty, PVC circular rigid Conduits for Electrical & Communication System with required Solid Long Bends, Couplings, GI Wire etc., in Floor, Walls, Brick, Block Masonry as per the detailed specification.
26125mm Dia, 2mm wall thickness PVC round rigid conduits with 50 mm deep Junction boxes
262Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.
263Wiring with 2 Runs of 6.0 Sq.mm for Phase & Neutral and2 Runs of 2.5 Sq.mmfor Earth
264Wiring for Power Points with 2 Run of 4.0 Sq. mm Copper Wire for Phase, Neutral and 1 Run of 2.5 Sq.mm Copper Wire for Earthing.
2653 Runs of 2.5 Sq.mm Copper Wire for Phase, Neutral and Earthing.
266Wiring with 2 Runs of 1.5 Sq.mm for Phase, Neutral and 1 Run of 2.5 Sq.mm copper wires for Earthing
267Wiring for Light/Power Points with 1 Run of 1.5 Sq.mm Copper Wire.
268Wiring for Light/Power Points with 1 Run of 2.5 Sq.mm Copper Wire.
269Wiring and termination for Telephone point with 1 Run of 0.61 mm dia, 250 V grade PVC insulated, twin twisted, single pair, tinned copper wire from Telephone Junction Box to Telephone points in concealed conduit/ PVC Trunking including of supply of Telephone wire.
270Wiring for Television point including supply of RG-6 (21-F) Co-axial cable from terminal junction box to the TV pointprovided in the living hall in each Quarter in existing concealed PVC Rigid conduits/Casing & Cappingincluding connecting the same to the socket. as per the detailed Specification. (Quantity indicated is running length of 1 Run of Wire)
271Removal and reinstallation of following Electrical Items as per the site condition and asper the detailed specification and as directed by the Engineer-in-Charge.
272Various sizes of switch boxes including termination of wires in the switch boxes.
273Rerouting of existing wiring in the already laid PVC trunking including re-termination.
274Removal of Old Wiring, Light Fittings, Fuse DB, Switch Boards, Embedded Pipes, Junction Boxes, Pull Boxes, Telephone DBetc., partially or full in Category-C/SA type Residential Quarters and returning them to Departmental StoresGSO/IGCAR at plant site as per site conditionand asper the detailed specification and as directed by the Engineer-in-Charge.
275Type C / SA type Quarters.
276Cleaning of Ceiling / Pedestal / Wall mounting/Air circulator Fans/ fitted at different levels in various labs/Buildings as per the scope of work.
277Supply, Installation, Testing and Commissioning of Static Energy Meter with RS 485 Port Compatibility along with necessary fixtures and fixing arrangementsincluding removal of Existing Meters as per the detailed specification and as directed by Engineer-in-charge.
2781 Phase 10-40AStatic Energy Meter