Tender For Construction Of Health Sub Centre (Hsc) At Mahuda, Block-Baghmara, District-Dhanbad., baghmara-Jharkhand

Zilla Parishad-ZP has published Tender For Construction Of Health Sub Centre (Hsc) At Mahuda, Block-Baghmara, District-Dhanbad.. Submission Date for this Tender is 19-02-2024. Building Work Tenders in baghmara Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

42215405
Tender For Construction Of Health Sub Centre (Hsc) At Mahuda, Block-Baghmara, District-Dhanbad.
Open Tender
Indian
Jharkhand
baghmara
19-02-2024

Tender Details

Construction Of Health Sub Centre (Hsc) At Mahuda, Block-Baghmara, District-Dhanbad.

Key Value

Document Fees
INR 10000 /-
EMD
INR 109900.0 /-
Tender Value
INR 54.94 Lakhs /-

BOQ Items

Name of Work: Construction of Health Sub Centre (HSC) at Mahuda, Block-Baghmara, District-Dhanbad.
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil itemB) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. (5.1.1)
2Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) (5.1.2)
3Earth filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earthobtainedfrom excavation offoundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I.(mode of measurement compacted volume) (5.1.7)
4Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) (5.1.10)
5Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.(5.6.3)
6Providing and laying in position cement concete of soecified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (5.3.1.6)
7Providing and laying in position specified grade of reinforced cement concerte, excluding the cost of centering, shutteing, finishing and reinforcement- All work up to pilnth level1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (5.3.9.1)
8Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) (5.3.10)
9Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). (5.3.11)
10Providing Tor steel reinforcement of 8mm,dia rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL & TATA Steel 20% (5.5.4)
11Providing tor steel reinforcement of 10 mm Dia bars as per approved design and drawingwith cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/I. 15% [5.5.5(a)]
12Providing tor steel reinforcement of 12 mm to 20 Dia bars as per approved design and drawingwith cutting, bending and binding with annealed wire with cost of wire removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/I. 65% [5.5.5(b)
13Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (5.3.17)
14Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts (5.3.17.6)
15Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers (5.3.17.5)
16Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (5.3.17.2)
17Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (5.3.17.3)
18Providing designation 75B brick work inC.M(1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. (5.2.6)
19Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. (5.2.52)
20Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.(5.2.54)
21Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary (DSR 6.15)
22Supplying, fitting and fixing 35mm thick solid core type non- decorative single leaf flush door shutter in door and windowswith black board core blended with high qualityphenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. (5.4.38)
23Prividing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :(50x20mm) (DSR 9.40.2.2)
24Providing and fixing bright finnished brass 100 mm mortice latch and lock ISI marked, with six levers and a pair of anodised (anodic coating not less than grada AC10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (DSR 9.103)
25Providingandfixingaluminiumhangingfloordoorstopper,ISI marked,anodised(anodiccoatingnotlessthangradeAC10as perIS:1868)transparentordyedtorequiredcolourand shade, with necessary screws etc. complete.(DSR 9.101.2)
26Providing and fixing aluminium extruded section body tubular type universalhydraulicdoorcloser(havingbrandlogowithISI,IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.(DSR 9.84)
27Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (5.5.35)
28Providing and fixing pressed steel door frames conforming to IS 4351 , manufactured from commercial mild steel sheet of 1.60 mm thickness , including hinges , jamb , lock jamb , bead and if required angle threshold of mild steel angle of section 50*25 mm , or base ties of 1.60 mm , pressed mild steel welded or rigidly fixed together by machanical means , including M.S. pressed butt hlnges 2.5 mm thick with mortar guards, lock strike -plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineer-In- charge. Fixing with carbon steel galvanished dash fastener of required dia and size ( to be paid forseparately (DSR 10.14.2)
29Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) (5.5.12)
30Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels (20 x 10 x 2mm) at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38 mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. (5.5.14)
31Supplying fitting and fixing glass panes including supplying putty. Beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I. (5.5.57.3)
32Providing and laying Doublecharge vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorptionless than 0.08% and conforming to IS: 15622 / ISO 13006 of approvedmake, in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . (5.6.28)
33Providing and fixing granite 18 mm thick gang saw cut, mirror pollished, premoulded and prepollshed mechine cut for flooring, kichen, platform, vanlty counters, window sills, faclas and similar locations of required size, approved shade, colour and texture lald over 200 mm thick base cement mortar 1:4 ( 1 cement: 4 coarse sand). Joints treated with white cement, mixed with matching pigment epoxy touch ups, including rubbing curing moulding and polishing to edges to give high glloss finish etc, complete al all levels. (DSR 8.2.2.2)
34Providing edge moulding to 18 mm thick marble/granite stone counters, vanities etc. Including machine polishing to edge to give high gloss finish etc, Complete as per design approved by Engineer-in- Charge. (DSR 8.3.2)
35Extra for providing opening of required size & shape for wash basin/kichen sink in kitchen platform vanty counter and similar location in marble/Granite/stone work including necessary holes for pillar laps etc. Including moulding rubbing and polishing of cut edges etc complete (DSR 8.5)
36Providing and fixing stone slab with table rubbed edges rounded and polished of size 75*50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of approprate width with chase cutyter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement 2 corse sand : 4 graded stone aggregate 6 mm normal size) as per direction of engineer ( DSR 8.10.2)
37Providing and laying 1st quality Ceramic glazed wall tiles thicness to be specified by the manufacturer) in wall over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing pollshing and cost of curing. taxes and royalty all complete as per bullding pecification and direction. (DSR 8.31)
38Providing and laying Ceramic glazed floor tile of size 300x300mm (Thikness to be specifyed by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, lvory, Grey, Fume Red Brown, laid on 20mm thik cement morter 1:4(1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching plgment etc, complete. (DSR 11.37)
39Providing and Laying 25mm. Thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of time morter (1:1:1) (Line putty : surkhl: coarse sand) laid over and jointed with grey cement slurry mixed with plgment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curring, taxes and royalty all cmplete as per building specification direction of E/i. 600x600mm Size. (BCD 5.6.19)
40Providing and laing 25mm. Thick kotah stone riser of steps. Skirting and pillers of approved size, texture and colour over 13mm thick cement morter(1:3) and jointed with grey cement slurry mixed with plgment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. (BCD 5.6.20)
41Providing single layer Narla tiles in foof including cost of all labour and materials taxes, all complete as per building specification and direction of E/I (BCD 5.9.6)
42Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement :3 fine sand) as per standard design: (DSR 12.21)
43Making khurras 45x45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C sheet 1 m x 1m x400 micron, finished with 12mm cement plaster 1:3(1 cement : 3 coarse sand) and a coat of neal cement, rounding the edges and making and finishing the outlet complete (DSR 12.22)
44Water proofing for Old and New Roof Slab :- Providng and laying water proofing treatment on roof slab by applying tow component, factory a designed ready to use, acrylic modified flexible (e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand-Sika India Pvt. Ltd./MYK Schomberg/ Dr Fixit/Fosroc material applied with brush, roller or spray waterproofing coating as per manufacturer specification-With following steps:- (a) Suface preparation:- Providing and cleaning of concrete surface to remove dust, iol, grease including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools, complete. Ponding test to be done after pugging all outlets and to be cheded from soffit to identify seepage, ladkage. On indentification of seepage, cement grouting to be done with non shirnk expanding admixture of Sika India Pvt. Ltd. MYK Schombeg/Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints usch as those between the parapet wall and the roof slab etc. Shall be chamfered with "150mmX"150mm fillet lf mortar (Cement sand- 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or requivalent Before chamfering a prime coat shall be give with the slurry of acrylic polymer Reparing surface irregularities, damaged concretein base slab, dead cracks if any, with and acrylic polymer modified reqpair mortar including a coat of bonding agent of the same with cement slurry including all materials labour, tools, complete. (b) 1st Coat :- Apply 1st coat of two component acrylic modidied, ready to use, flexible cementitious material on surface saturated dry roof and inisde wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm oil Fibre glass cloth to lay when the fist layer is still greeb. 1st ciat sgiykd ve aookued @1.50/kg/sqmt/coat for the purpose of measurement the entire treated surface will be measured." (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified ready to use flexible cementitious materials right angle to the "1st coat over the glass fibre laid surface. 2nd coat should be applied@ 0.7kg/sqmt/coat. For the purpose lf measurment the entire treated surface will be measured." alter three days of drying the 2nd coat, the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, teakage from soffit and if found necessary rectification to e be done as per satisfation of E/I. The Watqrproofing Brand: *Sika Topseal 109hi/Fosroc Brushbond RFX/ Dr Fixit Pidiffine 2KI MYK Aqraiin TG Product Performance- Chemical Base Part A.Acrylic copol,mer, Part 13 Specially graded cementitious powder-Density 1.6 kg/l (mixed density) at +270 Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.) 4624) Slant-shear Bond Strength-4 N/mm2 (According to FIP 5.15) Flongation at Break- 35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTMD 2370) (D )Protection of treated with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in altematepanels lf 2mtx2mt keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS2645@ of 100 ml perbag of cement tobe added in the screed concrete (paid separately for this items) all corners shal be charfered with 150mmx150mm fillet. The rain water outlets shal be just leveled with the scree concrete to ensure smooth descharge of water- the perpheral gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensisive epoxy putty of Sika India Pvt.Ltd./IVIYK Schomberg/Dr Fixit / Fosroc. For the purpose of measurement the entire treated surface will be meaured." (5.12.1)
45Covering of treated surface with PCC :- Providing 25mm thick Cement Concrete M-20 (1:1.5:3) raintaining slope in alternate 2 mix 2mt. Panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing erite nt concrete in mixe with admixture of integral water proofing and placing, position, striking royalty all complete as per building specification and direction of E/I. (5.12.2)
46Providing and filling Groove between 25 mm PCC Panels with Polysulphide Sealant(Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with18% GST) brand:- Sika- Polysulphide Fosroc-l-hloflex 600 Dr Flxit Pidiseal PS (42P), MYK seal PS or Eulvallent (5.12.8)
47Toilet/kitchen water proffing (1) Surface preparation by grinding machine, Cleaning, creak filling etc. Complete. Providing and laying water proffing treatment in sunken protion of WCs, bathroom etc. by applying cement slurry mixed with water proofing cementcompound consisting of applying. (a) First ;ayer of slurry of cement @ 0.488 Kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @0.242kg/sqm mixed with water proofing cement compound @0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 sealing of all joints comes juctions of pipes and masonry with polymer mixed slurry. (DSR 22.5)
48Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.3)
49Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.6)
50Providing and applying white cement based putty of average thickness 1 mm of aproved brand and manufacture ofev the plastered wall surface to prepare the surface even and smooth complete (DSR 13.80)
51Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. (5.3.24)
52Finishing walls with acrylic smooth exterior paint of required shade, new work ( Two or more coas app;ied @ 1.67 ltr/10sqm over and incuding priming coat of exterior primer applied @2.20 kg/10sqm (DSR 13.46.1)
53Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. (5.8.18)
54Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. (5.8.41+5.8.45)
55Providing and fixing aluminium work for doors, windows ventilators and partitions with exruded builtt up standard tubular sections/appropritate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and aize including necdessary filling up tthe gaps of fundtions. i.e. at top bottom and sides with required EPDM rubber/neoperrne gasket etc. Aluminium sections shall be smooth. rust free straightt mitred and joined mechanically wherever required including cleat andle. aluminium snap beading for glazing panelling. C.P brass/ stainless steel screw For fix portion : - Powder coated aluminium ( minimum thickness of powder coating 50 micron) (DSR 21.1.2)
56For shutters of doors windows & ventilators including providing and fixing hinges/plvots and miking provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separatrly) powder coated aluminium ( minimum thickness of powder coating 50 micron) (DSR 21.1.2.2)
57Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth. (5.3.8)
58Providing and fixing circular/hexagonal cast iron or M.S sheet box for celling fan clamp of internal dia 140 mm 73 mm height top lid of 1.5 mm thick MS sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron/MS sheet box by means of 3.3 mm diia round headed screws. one lock at the corners. Clamp shall be made of 12 mm dia. M.S bar bent tto shape as per standard drawing. (DSR 10.18)
59CARRAIGE OF MATERIALS SAND (Lead upto 20 KM)
60CHIPS (Lead upto 20 KM)
61BRICKS (Lead upto 10 KM)
62Cement +Steel (Lead upto 10 KM)
63DEEP BOARING Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in ruralareaforinstalationofpumpset withHydrolicDTHRig machineall complete includingallmaterials,tools,drilingrig,aircompressureandequipmentsaswellas fule,lubricantsandcostoftransportationofrigmachineanndothervehicalupto Site. (M1035) (a) From 0.00 M to 50.00 M below G.L.
64(b) From 50.0 M to125.00 M
65(c) From125.0 M to150.00 M
66Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticizedPVCmediumwellcasing(CM)pipeof required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia (M1048)
67DevelopmentoftubewellinaccordancewithIS:2800(partI)andIS:11189,to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer in-charge (M1042)
68Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia (DSR 23.13.3)
69Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewellasperIS:2800(partI),includingnecessarybolts&nutsofrequiredsize complete. 200 mm clamp (DSR 23.14.3)
70Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for workingon415+10,3HP,50Hz,ACsupplywithcableguard,thurstcarbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as permanufacturersdesign. Antithurststream linednon returnvalve shallbe provided with pump, 3 meter submersible copper conductor cable in single/double runshallbeprovidedwitheachpump.Submersiblepumpset100mmdia(with Polypropylene/Noryl Impeller) up to 20 stages 2 HP (M1055)
71Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. (M1065)
72Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etcall complete job as per direction of E/I. (M1062)
73Supply fitting and fixing lowering 40 mm dia G.i. collumn pipe - do - do - all complete job as per direction of E/I. (M930)
74SEPTIC TANK Earthwork in excavation in foundation trenches in ordinarysoil(videclassficationofsoilitem-A)and disposal of excavated earth as obtained to a distance upto50mincludingalllifts,levelling,rammingthe foundation trenches, removing roots of trees shurbs all complete as per approved design building specification and direction of E/I. (5.1.1)
75Extraforearthworkinhardsoilasperspecification and direction of E/I. (vide classfication of soil item - B) (5.1.2)
76Providingcoarsecleansandinfillinginfoundation trenches or in plinth including ramming and watering in layersnotexceeding150mmthickwithallleadsand lifts including cost of all materials, labour, royalty and taxesallcompleteasperbuildingspecificationand directionof E/I.(Modeofmeasurementcompacted volume) (5.1.10)
77Providing designation 75Bwork in C.M. (1:6) in foundationandplinthwithapprovedqualityofclean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I. (5.2.6)
78Providingandlayinginpositionspecifiedgradeof reinforcedcement concrete, excludingthe cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3(1cement:1.5coarsesand(zone-III):3 graded stone aggregate 20 mm nominal size) (5.3.9)
79Reinforced cement concrete work in walls (any thickness), includingattachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3(1cement:1.5coarsesand(zone-III):3 graded stone aggregate 20 mmnominal size) (5.3.10)
80Reinforcedcementconcreteworkinbeams, suspended floors, roofs having slope up to 15° landings,balconies,shelves,chajjas,lintels,bands, plainwindowsills,staircasesandspiralstaircases above plinth levelup tofloorfive level,excluding the cost of centering, shuttering, finishing and reinforcement,with1:1.5:3(1cement:1.5coarse sand(zone-III):3gradedstoneaggregate20mm nominal size). Slab (5.3.11)
81Centeringandshutteringincludingstrutting,propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (5.3.17.3)
82ProvidingTMTsteelreinforcementabove16mmto 36mmdiabarsasperapproveddesignanddrawing excluding carriage ofM.S. roads(Straight orin coils) to work site, cutting, bending end binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I. 10mm dia (5.5.4)
83Providing designation 75 B one brick flat soling joints filledwithlocalsandincludingcostofwateringtaxes royaltyallcompleteasperbuildingspecification& direction of E/I (5.6.3)
84Providing 12mm cement plaster (1:3) with clean coarsesandofF.M.1.5includingscreening,curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. (5.7.1)
85Providing1.5mmcementpunningincludingcuring, carriage of water with all leads and lifts as per building specification and direction of E/I.(5.7.11)
86Carriage of Materials- Bricks (Lead upto 10 KM)
87Sand (Lead upto 20 KM)
88Stone Chips (Lead upto 20 KM)
89Cement+TMT (Lead upto 10 KM)
90Sanitary work Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. Of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. "P" trap 15liters C.I. Pull and let go flushing cistern of names or other I.S.S. Equipment make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pert of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxideprimer etc. all complete as per specification and direction of E/I. (A) 580 mm long with 10 ltr low level PCV cistern (3.2.1)
91Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With "P" trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification and direction of E/I. (b) With 10 ltr low level PVC cistern (3.2.2 1-B)
92ProvidingandfixingwashbasinwithC.I.rackets,15mmC.P.brasspillar taps, 32 mm C.P. brass waste of standard pattern, ncludingpainting of fittings and brackets, cutting and making good the walls wherever require : WhiteVitreousChinaWashbasinsize550x400mmwithapairof15mm C.P. brass pillar taps (17.7.3)
93Supplying, fitting and fixing the following items complete with all materialsasperspecificationanddirectionofE/I.(a)glassshelfwithC.P. Brass rail.(i) 600X125mm glass shelf complete (3.1.21)
94Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260mmfromthe centre of the waste coupling 77 mmbreadth with25 mm minimum water seal, weighing not less than 260 gms. (DSR 17.70.1)
95Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. (17.71)
96Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms (DSR 17.72)
97ProvidingandfixingC.P.brassbibcockofapprovedqualityconfirmingto IS:8931 (18.49)
98ProvidingandfixingC.P. brassanglevalveforbasinmixerandgeyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore (18.53)
99Providing and fixing toilet paper holder : C.P. brass (18.53.1)
100Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter (12.41.1)
101110 mm diameter (12.41.2)
102Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm (12.42.1)
103Single tee with door 110x110x110 mm (12.42.3)
104Bend 87.5° 110 mm (12.42.5)
105Shoe (Plain 110 mm) (12.42.6)
106Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4(1 cement : 4 coarse sand) and making good the wall etc. complete. 75mmdia (12.43.1)
107110 mm dia (13.43.2)
108ProvidingandfixingCPVCpipeshavingthermalstabilityforhotandcold watersupplyincludingallCPVCplainandbrassthreadedfittingsincluding fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work -Exposed on Wall 20 mm nominal outer dia pipes (18.7.2)
10925 mm nominal outer dia pipes (18.7.3)
11032 mm nominal outer dia pipes (18.7.4)
11140 mm nominal outer dia pipes (18.7.5)
11250 mm nominal outer dia pipes (18.7.6)
113ProvidingandfixingCPVCpipeshavingthermalstabilityforhotandcold watersupplyincludingallCPVCplainandbrassthreadedfittingsincluding fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes andfittingswithonestepCPVCsolventcementandthecostofcutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc. 15 mm nominal outer dia pipes (18.8.1)
11420 mm nominal outer dia pipes (18.8.2)
11525 mm nominal outer dia pipes (18.8.3)
11632 mm nominal outer dia pipes (18.8.4)
117Providingandfixinginposition 25mmdiametermosquitoproofcoupling of approved municipal design. (17.30)
118Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank,ISI:12701marked,withcoverandsuitablelocking arrangement andmakingnecessaryholesforinlet,outletandoverflowpipesbutwithout fittings and the base support for tank. (DSR 18.48)
119ELECTRICITY Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C
120Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
121Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
122Wiring for circuit / submain wiring alongwith earth wire with the following sizesofFRPVCinsulatedcopperconductor,singlecorecablein surface/ recessed PVC conduit as required CIRCUIT / SUBMAIN WIRING 2x1.5sq mm + 1x1.5 sq mm earth wire
1232x2.5sq mm + 1x2.5 sq mm earth wire
1244x2.5sq mm + 2x2.5 sq mm earth wire
1254x10 sq mm + 2x6 sq mm earth wire.
126Supplyinganddrawingco-axialTVcableRG-6grade,0.7mmsolid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
127Supplying andfixing offollowing sizes ofPVCconduit alongwith the accessoriesinsurface/recessincludingcuttingthewallandmaking good the same in case of recessed conduit as required. 20mm dia
12825mm dia
129Supplyingandfixingfollowingmodularswitch/socketontheexisting modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps one way switch
13015/16 amp one way switch
1315/6 amp 3 pin socket outlet
1325/16 amp 6 pin socket outlet
133TV anteena Socket Outlet
134Supplyingandfixingsteppedtypeelectronicfanregulatoronthe existing modular plate switch box including connections but excluding modular plate etc. as required.
135Supplyingandfixingmodularblankingplateontheexistingmodular plate & switch box excluding modular plate as required.
136Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
1374/5 Module (78mm x140mm x 50mm)
1386 Module (78mmX205mmx50mm)
139Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
140Supplyingandfixingbrassbatten/angleholderincludingconnection etc. as required.
141Supplying and fixing Dingdong sound call bell single phase, 230 volts, complete as required.
142Installation,testingandcommissioningofceilingfan,includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.
143Installation of exhaust fan up 450 mm sweep in the existing openingincludingmakingtheholetosuitthesizeofabovethefan, making good the damage, connection, testing, commissioning etc. as
144Supplyingandfixing20amps,240volts,SPNindustrialtype,socket outlet,with2poleandearth,metalenclosedplugtopalongwith20 amps“C” curve,SP, MCB,in sheetsteelenclosure,onsurfaceor in recess,withchainedmetalcoverforthesocketoutletandcomplete with connections, testing and commissioning etc. as required.
145Supplyingandfixingfollowingways,horizontaltypethreepoleand neutral,sheetsteel,MCBdistributionboard,415volts,on surface/recess, completewith tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door Horizontal Type
146Supplyingandfixing6Ampto32Amprating240volts,10KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of followingpolesintheexistingMCBDBcompletewithconnections, testing and commissioning etc.,as required. 6 / 32 Amp Single Pole
14740 Amp TPN
148Supplying and fixingSingle pole blanking plate in the existing MCB DB complete etc. as required.
149Supplyingandfixingoffollowingratingdoublepole(Singlepole& neutral),240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required. 40 Amps
150Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
151Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
152Providingandfixing6SWGdiaG.I.wireonsurfaceorinrecessfor loopearthingalongwithexistingsurface/recessedconduit/submain wiring/ cable as required.
153Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming toIS-7098. (Part-I). 4 core,16 sq.mm.
154Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
155Laying of one number PVC insulated and PVC sheathed / XLPE power cableof1.1KVgradeoffollowingsizedirectingroundincluding excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
156Supplyingandmakingendterminationwithbrasscompressiongland andaluminiumlugsforfollowingsizeofPVCinsulatedandPVC sheathed/XLPEaluminiumconductorcableof1.1KVgradeas required. 4 X 16 sq. mm (28mm)
157SITC of following rating recess / surface mounted LED round / square shapedownlightluminariewithpressurediecasthousingforsingle phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. Make:- Havells/Philips/Crompton/Wipro. 18 /20 W LED Round Down Light (Surface)
158Bulk Head fitting with 9/10Watt LED.
159S.I.T.C offollowing ratingsurface mountedLEDTubeLighting Fitting Suitablefor230V50Hz,SinglePhaseSupplyetc.completeas 10/12 W LED Tube Light
16020/22 W LED Tube Light
161SITCof 300mm(12")Exhaustfan(Metalbody)suitableforsingle phase230volts,50Hz.,ACsupplycompletewithmotor, louvers/shutters etc. complete as required.Make :- Usha/Crompton / Havells .
162Supply, Installation, Testing and Commissioning of following size fan 3 BladesconfirmingtoIS:374:2019includingwiringthedownrodsof strandedfor230V50Hz,singlephasesupplyetc.completeas required 1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
163Goods & Service Tax (G.S.T.) -
164Labour Cess -